A Seminar Report On Space Mouse
A Seminar Report On Space Mouse
A Seminar Report On Space Mouse
audience what SPACE MOUSE is all about. y To explain it s advantage over other technology. y FUTURE SCOPE of the existing technology.
motion and your clicks and sends them to the computer so it can respond appropriately. y An ordinary mouse detects motion in the X and Y plane and acts as a two dimensional controller.
Space Mouse
y Space Mouse is a professional 3D
controller specifically designed for manipulating objects in a 3D environment. y It permits the simultaneous control of all six degrees of freedom - translation rotation or a combination. y The device serves as an intuitive man-machine interface. y Space mouse is developed by the DLR(Deutsches Zenturum far Luft-und Raumfahrt) institute of robotics and mechatronics.
Basic Principle
Mechatronics Engineering
It is simply the applications of latest techniques in precision mechanical engineering, electronic and computer control, computing systems and sensor and actuator technology to design improved products and processes. The new sensor and actuator generation does not only show up a high degree of electronic and processor integration but also fully modular hardware and software structures.
Multisensory Concept
Mechatronics Engineering
Mechanical Engineering
Co p ting
Electronics Engineering
y A typical Mechatronic system picks up signals processes them and generates forces and motion as an output. y In effect mechanical systems are extended and integrated with sensors (to know where things are), microprocessors (to work out what to do), and controllers (to perform the required actions).
Basic Idea
y Apply innovative controls to extract new level of
performance from a mechanical device. [It means using modem cost effective technology to im rove product and process performance, adaptability and flexibility.]
Multisensory Concept
y The 20khz lines
Digital PreProcessing
Analog Conditioning
Power Supply
connecting all sensor and actuator systems in a galvanically decoupled way and high speed optical serial data bus (SERCOS) are the typical examples of multi sensory and multi actuator concept for the new generation robot envisioned.
Basic Idea
y The new sensor and actuator generation does not only
show up a high degree of electronic and processor integration but also fully modular hardware and software structures. [Optically measuring force-torque-sensor for assembly operations were integrated inside plastic hollow balls, thus generating 6-degree of freedom hand controllers (the DLR control balls).]
component forcetorque-sensor systems. y miniaturized triangulation based laser range finders. y integrated inductive joint-torque-sensor for light-weight-robot.
Why 3D Motion?
Industrial Robots
It made up the most prominent category needing six degrees of freedom by maneuvering six joints to reach any point in their working space with a desired orientation.
3D Graphics
y Gently push, pull,
twist or tilt to simultaneously pan, zoom and rotate. y Increase pressure to go faster or decrease pressure to make intricate adjustments.
Basic Principle
y The measuring system consists of an inner and an
outer part. y The measuring arrangement in the inner ring is composed of the LED, a slit and perpendicular to the slit on the opposite side of the ring a linear position sensitive detector (PSD). y The slit / LED combination is mobile against the remaining system. Six such systems (rotated by 60 degrees each) are mounted in a plane, whereby the slits alternatively are vertical and parallel to the plane.
inside the outer part and connected via springs with the LED-slit-basis. y The springs bring the inner part back to a neutral position when no forces / torque are exerted. y The whole electronics including computational processing on a one-chipprocessor was already integrable into the ball by means of two small double sided surface mount device (SMD) boards.
linear and rotational displacements as generated by the forces/ torques of a human hand, which were then computationally transformed into translational / rotational motion speeds.
Disadvantages
y Movements were measured by electromagnetic or
ultrasonic means, with the human head having problems in controlling translational speeds. y Moving the hand around in free space leads to fairly fast fatigue.
Basic Concept
The wear resistant and drift free opto electronic, 6 component measuring system was optimized to place all the electronics, including the analogous signal processing, AT conversion, computational evaluation and power supply on only one side of a tiny SMD- board inside Magellan's handling cap.
Basic Principle
y The tedious mechanical optimization,
where the simple adjustment of the PSD's with respect to the slits played a central role in its construction, finally led to 3 simple injection moulding parts, namely the basic housing, a cap handle with the measuring system inside and the small nine button keyboard system. y The housing, a punched steel plate provides Magellan with the necessary weight for stability; any kind of metal cutting was avoided. y The small board inside the cap contains the automatically mountable springs as well as overload protection.
y The springs were optimized in the measuring system so that they no longer show hysteresis; nevertheless different stiffness of the cap are realizable by selection of appropriate springs. y Magellan was constructed as flat as can be so that the human hand may rest on it without fatigue.
cap of Magellan is sufficient for generating deflections in X, Y, and Z planes, thus shifting a cursor or flying a 3D graphics object translationally through space. y Slight twists of the cap cause rotational motions of a 3D graphics object around the corresponding axes. y Pulling the cap in the Z direction corresponds to zooming function. y Moving the cap in X or Y direction drags the horizontally and vertically respectively on the screen.
Advantages
y It only needs a few milliamperes of
current supplied through the serial port of any PC or standard mouse interface. y It does not need a dedicated power supply. y The electronic circuitry using a lot of time multiplex technology was simplified by a factor of five, compared to the former control balls. y The user can handle the object on the screen as he were holding it in his own left hand and helping the right hand to undertake the constructive actions on specific points lines or surfaces or simply by unconsciously bringing to the front of appropriate perspective view of any necessary detail of the object.
Precaution
y Use of handshake signals
(RTSSCTS) are recommended for the safe operation of the space mouse. y Without these handshake signals loss of data may occur.
System Requirements
y Intel Pentium 4/III/II/Celeron or AMD-K6/Athlon
processor based system. y 10 Megabytes free disk space for driver and plug-in installation (CD-ROM device required). y USB 1.1 or greater (USB only).
Software Drivers
Serial
=>Unix drivers for SGI, HP, SUN & IBM. =>Linux drivers. =>Windows NT, 2000, XP
USB
cont ..
y Settings to adjust sensitivity and motion control to the users preference. y Small form factor frees up the desk space. y Double productivity of object manipulation in 3D applications. y Natural hand position (resting on table) eliminates fatigue.
device the necessity of going back and forth to the menu is eliminated. y Drawing times is reduced by 20%-30% increasing overall productivity. y With the Magellan device improved design comprehension is possible and earlier detection of design errors contributing faster time to market and cost savings in the design process.
Future Scope
Magellan's predecessor, DLR's control ball, was a key element of the first real robot in space, ROTEX- (3), which was launched in April 93 with space shuttle COLUMBIA inside a rack of the spacelab-D2. The robot was directly tele operated by the astronauts using the control ball, the same way remotely controlled from ground (on-line and off line) implying "predictive" stereo graphics. As an example, the ground operator with one of the two balls or Magellan s steered the robot's gripper in the graphics pre-simulation, while with the second device he was able to move the whole scenery around smoothly in 6 dot Predictive graphics simulation together with the above mentioned man machine interaction allowed for the compensation of overall signal delays up to seven seconds, the most spectacular accomplishment being the grasping of a floating object in space from the ground. Since then, ROTEX has often been declared as the first real "virtual reality" application.
Conclusion
The graphics simulation and manipulation of 3D volume objects and virtual worlds and their combination e.g. with real information as contained in TV images (multi-media) is not only meaningful for space technology, but will strongly change the whole world of manufacturing and construction technology, including other areas like urban development, chemistry, biology, and entertainment. For all these applications we believe there is no other manmachine interface technology comparable to Magellan in its simplicity and yet high precision. It is used for 3D manipulations in 6 dof, but at the same time may function as a conventional 2D mouse.
References
J. HeintB, G. Hilzinger
Device for programming movements of a Robot, Enrop. Patent No. 0.108.348; US-Patent No. 4,589,810 J. Dietrich, G. Plank, H. Krans Optoelectronic System Housed in Plastic Sphere, Emop. Patent No. 0 240 023; US-Patent No. 4,785,180; JP-Patent No. 1763 620 G. Hirzmger and J. Dietrich, B. Gombert, J. Heindi, K. Landzettel, J. Schott The sensory and telerobotic aspects of the spare robot technology experiment ROTEX,Int. Symposium "Artificial Intelligence, Robotics and Automation, in Space",Toulouse Labege, France, Sept. 30 - Oct. 2, 1992. www.howstuffworks.com www.wikipedia.com www.google.com
Thank you
Any Queries