EXPERIMENT
STANDARD TEST METHOD OF ULTRASONIC PULSE
VELOCITY THROUGH CONCRETE
(ASTM C597-97)
1
PURPOSE OF EXPERIMENT
To Find the Ultrasonic Pulse Velocity through concrete.
2
DEFINITIONS AND THEORY
The ultrasonic pulse velocity method could be used to establish
The homogeneity of the concrete
The presence of cracks, voids and other imperfection
Changes in the structure of the concrete which may occur with time
The quality of the concrete in relation to standard requirements
The values of dynamic elastic modulus of the concrete
3
EQUIPMENT REQUIRED
Pulse generator
A pair of transducers
An amplifier
Time Measuring circuit
Time display unit
connecting cables
4
PROCEDURE
Check the accuracy of the transit time measurements against the calibration
device.
Apply zero-time correction to the measured transit times.
Apply an appropriate coupling agent (such as water, oil, petroleum jelly, grease,
or other viscous materials) to the transducer diaphragms, the test surface, or both,
to avoid entrapped air between the contact surface of the diaphragms of the
transducers and the surface of concrete.
Press the faces of the transducers against the surfaces of concrete assuring good
contact between the two, and measure the transit time.
Measure the shortest direct path between the centers of the diaphragms.
5
DR. QAISER IQBAL (SUIT PESHAWAR) QI.CIVIL@SUIT.EDU.PK 6
CALCULATIONS
Calculate the pulse velocity as:
V= L/T
Where;
V = pulse velocity, m/s (ft/s)
L = distance between transducers, m (ft), and
T = effective transit time, (measured time minus zero time correction and
corrected for calibration errors)
7
CALCULATIONS
Calculate the pulse velocity as:
V= L/T
length = 12in= 0.0003048km
Ist reading = 1251 micro Sec V= .25km/sec
2nd reading = 1052 micro Sec V= .28km/sec
3rd reading = 1065 micro Sec V= .28km/sec
8
CONCRETE QUALITY CHECK
9
10