Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
SlideShare a Scribd company logo
Industry
RENTAL SOLUTIONS FOR
TEMPERATURE CONTROL & POWER GENERATION
Industry
  TEMPORARY
  TEMPERATURE CONTROL
  & POWER GENERATION
  SOLUTIONS
  Energyst Cat® Rental Power offers a complete range of
  Temperature Control and Power solutions designed to
  meet the temporary needs of industry. We provide both
  specific expertise and specially designed equipment for a
  variety of temporary industrial applications.

    COOLING AIR & LIQUIDS
  Cooling of air and liquids is vital to many industrial processes and basic
  operations. We offer a complete range of cooling equipment designed to work
  directly with existing industrial manufacturing installations to provide water or
  other liquid cooling. Our air cooling solutions work directly with your existing
  system or through purpose built temporary installations.


    HEATING AIR & LIQUIDS
  Heating of air and liquids is required for a variety of industrial operations. We
  offer a complete range of heating equipment designed to work directly with
  existing industrial manufacturing installations to provide air, water or other
  liquid heating. Our heating solutions work directly with your existing system or
  through purpose built temporary installations.


     POWER SUPPLY, TESTING, OPERATIONS
  We offer a complete range of Caterpillar® power generation equipment to
  satisfy the needs of small as well as large power projects. We equally offer
  transformers to ensure optimum power delivery as well as load banks for the
  testing of your existing generators. Complete on-site operations management
  through our professional technicians is also available.
Applications
 MANUFACTURING PROCESS OPTIMISATION
 Our solutions help companies optimise their manufacturing processes
 by providing better control over the temperatures at critical points on
 the production line. We work with your production experts to define
 the requirements and design solutions.


 SEASONAL TEMPERATURE MANAGEMENT
 Extreme ambient temperatures can adversely affect production
 efficiencies. Seasonal application of temperature control solutions to
 the production line can help resolve these problems and ensure
 production continuity.


 CAPACITY AUGMENTATION, TESTING
 Our temperature and power solutions are perfectly suited to support
 the testing of new production capacities or to augment existing
 capacity. In these instances our power generation solutions assure
 there’s enough power for all requirements.


 SCHEDULED MAINTENANCE
 With complete power and temperature control solutions from
 Energyst Cat® Rental Power your production is assured during regular
 scheduled maintenance periods. Our solutions experts can design the
 right installation for your needs well in advance.


 WORK ENVIRONMENTS
 Temperature extremes can affect work environments which can
 consequently affect productivity. Our complete power and
 temperature control solutions can be rapidly deployed to assure
 comfortable work environments.


 EMERGENCY INTERVENTION
 Power outage, periods of peak power or cooling consumption,
 generator breakdown, cooling equipment breakdown; these are
 everyday occurrences. Energyst Cat® Rental Power provides complete
 back-up power and temperature control solutions with 24/7 service
 coverage. Just ask an Energyst representative about a plan for you.


 TURNKEY SOLUTIONS, RAPID RESPONSE, 24/7 SERVICE
 We deliver turnkey solutions for all industrial applications - complete with detailed solution planning, the supply of all required
 equipment, rapid delivery, installation and commissioning as well as fuel supply and management. Our 24/7 service support
 also extends to all installed solutions. If you experience a problem, we’re there to help any time of day.
Industry
  Energyst Cat® Rental Power Fleet Overview
                                                 Chillers                                                Power Generators
                                                 Capacity 12 - 1000 kW                                   Capacity 20 - 455 kVA
                                                 Max. Pump Capacity 65 - 2 x 1700 ltr./min.              Caterpillar® Diesel Motor
                                                 Power Consumption 8 - 418 kW                            Internal Fuel Tank
                                                 Fluid Outlet Temp. +15°C to -15°C                       Water-Proof Housing


                                                 Air-to-Air Heaters                                      Power Modules
                                                 Capacity 70 - 350 kW                                    Capacity 600 - 2000 kVA
                                                 Airflow 4000 - 20000 m3/hr.                             Caterpillar® Diesel Motor
                                                 Power Consumption 2,5 - 8 kW                            Internal Fuel Tank
                                                 Fuel Consumption 7 to 36 ltr./hr.                       CSC-plated ISO Containers


                                                 Hot Water Systems                                       Transformers
                                                 Capacity 100 - 550 kW                                   Capacity 2000 - 6300 kVA
                                                 Max. Pump Capacity 65 - 400 ltr./min.                   50 Hz / 60 Hz
                                                 Power Consumption 2 - 13 kW                             Step down and step up capacity
                                                 Fuel Consumption 10 - 55 ltr./hr.                       CSC-plated ISO Containers

                                                 Heat Pumps                                              Load Banks
                                                 Capacity* 100/120 - 200/276 kW                          Capacity 100 kW - 6 MVA
                                                 Max. Pump Capacity 480 - 950 ltr./min.                  External Remote Control
                                                 Power Consumption 38 - 65 kW                            Mobile Units and Trailer Units
                                                 Fluid Outlet Temp. -15°C to 50°C                        ISO Containers


                                                 Air Handlers                                            Heat Exchangers
                                                 Capacity* 10/40 - 200/585 kW                            Pre-conditions temperatures
                                                 Airflow 2800 - 36000 m3/hr.                             Increases or decreases temperatures
                                                 Power Consumption 0,75 - 16,5 kW                        Used with liquid systems



                                                 Air-to-Air Coolers
                                                 Capacity 15 - 100 kW
                                                 Airflow 7000 - 20000 m3/hr.
                                                 Power Consumption 8 - 54 kW


                                                                                                                         *Cooling/Heating Capacity



We are continuously improving our fleet to meet our customers requirements.
For the latest information on our equipment range please visit us on the web at:
www.energyst.com
For enquiries related to solutions for your business, please contact us:
• 24/7 Telephone: 08457 697 450
• Or send us an email: info.uk@energyst.com

                                                                                                        Cat® Quality On Demand


                                                                                 RENTAL SOLUTIONS FOR
                TEMPERATURE CONTROL & POWER GENERATION
© 2007-2008 Energyst B.V. All rights reserved.

More Related Content

Energyst Industry Leaflet En

  • 1. Industry RENTAL SOLUTIONS FOR TEMPERATURE CONTROL & POWER GENERATION
  • 2. Industry TEMPORARY TEMPERATURE CONTROL & POWER GENERATION SOLUTIONS Energyst Cat® Rental Power offers a complete range of Temperature Control and Power solutions designed to meet the temporary needs of industry. We provide both specific expertise and specially designed equipment for a variety of temporary industrial applications. COOLING AIR & LIQUIDS Cooling of air and liquids is vital to many industrial processes and basic operations. We offer a complete range of cooling equipment designed to work directly with existing industrial manufacturing installations to provide water or other liquid cooling. Our air cooling solutions work directly with your existing system or through purpose built temporary installations. HEATING AIR & LIQUIDS Heating of air and liquids is required for a variety of industrial operations. We offer a complete range of heating equipment designed to work directly with existing industrial manufacturing installations to provide air, water or other liquid heating. Our heating solutions work directly with your existing system or through purpose built temporary installations. POWER SUPPLY, TESTING, OPERATIONS We offer a complete range of Caterpillar® power generation equipment to satisfy the needs of small as well as large power projects. We equally offer transformers to ensure optimum power delivery as well as load banks for the testing of your existing generators. Complete on-site operations management through our professional technicians is also available.
  • 3. Applications MANUFACTURING PROCESS OPTIMISATION Our solutions help companies optimise their manufacturing processes by providing better control over the temperatures at critical points on the production line. We work with your production experts to define the requirements and design solutions. SEASONAL TEMPERATURE MANAGEMENT Extreme ambient temperatures can adversely affect production efficiencies. Seasonal application of temperature control solutions to the production line can help resolve these problems and ensure production continuity. CAPACITY AUGMENTATION, TESTING Our temperature and power solutions are perfectly suited to support the testing of new production capacities or to augment existing capacity. In these instances our power generation solutions assure there’s enough power for all requirements. SCHEDULED MAINTENANCE With complete power and temperature control solutions from Energyst Cat® Rental Power your production is assured during regular scheduled maintenance periods. Our solutions experts can design the right installation for your needs well in advance. WORK ENVIRONMENTS Temperature extremes can affect work environments which can consequently affect productivity. Our complete power and temperature control solutions can be rapidly deployed to assure comfortable work environments. EMERGENCY INTERVENTION Power outage, periods of peak power or cooling consumption, generator breakdown, cooling equipment breakdown; these are everyday occurrences. Energyst Cat® Rental Power provides complete back-up power and temperature control solutions with 24/7 service coverage. Just ask an Energyst representative about a plan for you. TURNKEY SOLUTIONS, RAPID RESPONSE, 24/7 SERVICE We deliver turnkey solutions for all industrial applications - complete with detailed solution planning, the supply of all required equipment, rapid delivery, installation and commissioning as well as fuel supply and management. Our 24/7 service support also extends to all installed solutions. If you experience a problem, we’re there to help any time of day.
  • 4. Industry Energyst Cat® Rental Power Fleet Overview Chillers Power Generators Capacity 12 - 1000 kW Capacity 20 - 455 kVA Max. Pump Capacity 65 - 2 x 1700 ltr./min. Caterpillar® Diesel Motor Power Consumption 8 - 418 kW Internal Fuel Tank Fluid Outlet Temp. +15°C to -15°C Water-Proof Housing Air-to-Air Heaters Power Modules Capacity 70 - 350 kW Capacity 600 - 2000 kVA Airflow 4000 - 20000 m3/hr. Caterpillar® Diesel Motor Power Consumption 2,5 - 8 kW Internal Fuel Tank Fuel Consumption 7 to 36 ltr./hr. CSC-plated ISO Containers Hot Water Systems Transformers Capacity 100 - 550 kW Capacity 2000 - 6300 kVA Max. Pump Capacity 65 - 400 ltr./min. 50 Hz / 60 Hz Power Consumption 2 - 13 kW Step down and step up capacity Fuel Consumption 10 - 55 ltr./hr. CSC-plated ISO Containers Heat Pumps Load Banks Capacity* 100/120 - 200/276 kW Capacity 100 kW - 6 MVA Max. Pump Capacity 480 - 950 ltr./min. External Remote Control Power Consumption 38 - 65 kW Mobile Units and Trailer Units Fluid Outlet Temp. -15°C to 50°C ISO Containers Air Handlers Heat Exchangers Capacity* 10/40 - 200/585 kW Pre-conditions temperatures Airflow 2800 - 36000 m3/hr. Increases or decreases temperatures Power Consumption 0,75 - 16,5 kW Used with liquid systems Air-to-Air Coolers Capacity 15 - 100 kW Airflow 7000 - 20000 m3/hr. Power Consumption 8 - 54 kW *Cooling/Heating Capacity We are continuously improving our fleet to meet our customers requirements. For the latest information on our equipment range please visit us on the web at: www.energyst.com For enquiries related to solutions for your business, please contact us: • 24/7 Telephone: 08457 697 450 • Or send us an email: info.uk@energyst.com Cat® Quality On Demand RENTAL SOLUTIONS FOR TEMPERATURE CONTROL & POWER GENERATION © 2007-2008 Energyst B.V. All rights reserved.