Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
SlideShare a Scribd company logo
SAVITRIBAI PHULE NATYAMANDIR,
DOMBIVALI
SERVICES (ACOUSTICS)
CASE STUDY
SITE LOCATION
SITE
LOCATION
M. I. D. C, GHARDA CIRCLE,DOMBIVLI EAST.
LANDMARK: NEAR K.D.M.C. SPORTS COMPLEX.
PENDHARKAR COLLEGE
ACCESS TO THE SITE
PARKING
SERVICE ENTRY
MAIN ENTRY
VEHICULAR ENTRY
ENTRY TO
K.D.M.C. SPORTS
COMPLEX.
ACCESS TO THE SITE
AUDITORIUM
ROAD
KDMC SPORTS
COMPLEX
RESIDENTIAL
• ACCESS TO THE SITE: 4
ENTRANCE GATES
•WIDTH OF THE ROAD: 12
METRES AROUND THE
AUDITORIUM.
•PARKING: ON BOTH SIDES
OF THE AUDITORIUM.
•MAIN ENTRY IS
APPROXIMATELY IS 5M IN
LENGTH.SEPARATE
SECURITY CABIN IS
PROVIDED NEAR THE MAIN
ENTRY.
•A DIFFERENT VEHICULAR
ENTRY IS ALSO PROVIDED.
MAIN GATE SERVICE ENTRY
PARKING AREA ROAD AROUND THE
AUDITORIUM.
SECURITY CABIN
SCULPTURE PUMP HOUSE
PLAN OF AUDITORIUM
• TOTAL AREA OF THE AUDITORIUM : 5,500 SQ.M.
• MORE THAN 100 - 4 WHEELERS & 2-WHEELERS
• EXTRA PARKING AVAILABLE WITHIN THE COMPLEX
SECTIONS
ENTRANCE FOR STRUCTURE
STAFF ENTRY PERFORMER’S ENTRY
MAIN ENTRYPLAN
•ART GALLERY : 400 SQ. M.
ART GALLERY & WAITING AREA
GROUND FLOOR FIRST FLOOR
ENTRY & EXIT FOR AUDITORIUM
•THE STAGE IS AT A LEVEL OF +0.9M
•THE STAGE HAS 6 STAGE WINGS.
•THE STAGE FINISH IS MADE UP OF
WOOD.
•THE STAGE HAS 8 MIC POINTS
STAGE SPECIFICATIONS:
•LENGTH : 20 M
•WIDTH :13.5 M
•TOTAL HEIGHT : 20 M
•LIGHTS HEIGHT: 6 M
•ORCHESTRA PIT : 2
STAGE
BACKSTAGE :
3 GREEN ROOMS WITH
CHANGING ROOMS
WORKSHOP AREA
REHEARSAL ROOM
BACKSTAGE
A B
C D
E
F G H
•THERE ARE 8 BAYS
AND 19 ROWS.
•IT CAN ACCOMODATE
MAXIMUM OF 984
PERSONS.
•WIDTH OF ALLEY-1.5M
•A BAY-134 PERSONS
•B BAY-136 PERSONS
•C BAY-130 PERSONS
•D BAY-131 PERSONS
•E BAY-131 PERSONS
•F BAY-96 PERSONS
•G BAY-130 PERSONS
•H BAY-96 PERSONS
SEATING
ELECTRICAL ROOMS
MAIN ELECTRIC SUPPLY
TO THE ENTIRE BUILDING
IS PROVIDED IN THE
ELECTRICAL ROOM WHICH
IS ADJACENT TO THE
MAIN STAGE.
INVERTED CEILING PLAN
A.C SUPPLY AND CATWALK
CATWALK
AC DUCT ON STAGE
AC DUCT ON AUDITORIUM
RETURN AIR DUCTS AIR DUCT
CATWALK
•CATWALKS ARE USED TO:
SUSPEND LIGHT AND MICROPHONES DIRECTED
AT THE STAGE.
CONFERENCE HALLS
•2 CONFERENCE
HALLS
•150 SQ. M EACH
•CAPACITY : 200 EACH
•TERRACE : 300 SQ. M
•
•PANTRY PROVIDED.
GROUND FLOOR FIRST FLOOR
TOILETS
Public toilet
Private toilet
WALL PANELLING
•MATERIALS USED :
•BOROTIK PANELS ON
LOWER HALF
•MDF SHEET
MATERIALS
OBSERVATIONS
• RAMPS ARE PROVIDED.
• GLASS FACADE TO PROVIDE AMPLE SUNLIGHT AND
VENTILATION.
• LOBBIES ARE LARGE TO ACCOMMODATE THE HUGE
CROWD.
• THERE ARE NO CHAIRS OR BENCHES PROVIDED IN THE
WAITING AREA.IT IS A HUGE SPACE WITH GOOD LIGHT AND
VENTILATION.
• DIFFERENT ENTRANCE FOR BACKSTAGE.STORAGE
FACILITIES AND TOILETS ARE PROVIDED.
• NO QUICK CHANGE.
• THERE ARE SMOKE DETECTORS AND SPRINKLERS ON THE
CEILING TO DETECT SMOKE.
• MERITS-
• 1) SPACIOUS WAITING AREAS
• 2) SPACE BELOW THE MAIN
AUDITORIUM USED AS
EXHIBITION AREA FOR
PAINTINGS
• 3) SEPARATE ENTRY FOR
VEHICLES
• 4) 8 ENTRIES AND EXITS TO
AVOID CROWDING
• 5) SERVICE ENTRY IS
PROVIDED
• 6) PRACTICE HALLS,VIP
ROOMS,GUEST ROOMS ARE
PROVIDED
• DEMERITS-
• 1) NEGATIVE SPACES
FORMED AT THE
BACKSTAGE
• 2) THE DISTANCE BETWEEN
STAGE AND FIRST ROW IS
APPROXIMATELY 1.6 M
WHICH IS UNCOMFORTABLE
FOR THE FIRST ROW
AUDIENCE.
• 4) CANTEENS OR
REFRESHMENT AREAS ARE
NOT PROPERLY
MAINTAINED
MERITS AND DEMERITS

More Related Content

Savitribai phule natyamandir, dombivli - ACOUSTICS - AUDITORIUM - MUMBAI

  • 3. LOCATION M. I. D. C, GHARDA CIRCLE,DOMBIVLI EAST. LANDMARK: NEAR K.D.M.C. SPORTS COMPLEX. PENDHARKAR COLLEGE
  • 5. PARKING SERVICE ENTRY MAIN ENTRY VEHICULAR ENTRY ENTRY TO K.D.M.C. SPORTS COMPLEX. ACCESS TO THE SITE AUDITORIUM ROAD KDMC SPORTS COMPLEX RESIDENTIAL
  • 6. • ACCESS TO THE SITE: 4 ENTRANCE GATES •WIDTH OF THE ROAD: 12 METRES AROUND THE AUDITORIUM. •PARKING: ON BOTH SIDES OF THE AUDITORIUM. •MAIN ENTRY IS APPROXIMATELY IS 5M IN LENGTH.SEPARATE SECURITY CABIN IS PROVIDED NEAR THE MAIN ENTRY. •A DIFFERENT VEHICULAR ENTRY IS ALSO PROVIDED. MAIN GATE SERVICE ENTRY PARKING AREA ROAD AROUND THE AUDITORIUM.
  • 8. PLAN OF AUDITORIUM • TOTAL AREA OF THE AUDITORIUM : 5,500 SQ.M. • MORE THAN 100 - 4 WHEELERS & 2-WHEELERS • EXTRA PARKING AVAILABLE WITHIN THE COMPLEX
  • 10. ENTRANCE FOR STRUCTURE STAFF ENTRY PERFORMER’S ENTRY MAIN ENTRYPLAN
  • 11. •ART GALLERY : 400 SQ. M. ART GALLERY & WAITING AREA
  • 12. GROUND FLOOR FIRST FLOOR ENTRY & EXIT FOR AUDITORIUM
  • 13. •THE STAGE IS AT A LEVEL OF +0.9M •THE STAGE HAS 6 STAGE WINGS. •THE STAGE FINISH IS MADE UP OF WOOD. •THE STAGE HAS 8 MIC POINTS STAGE SPECIFICATIONS: •LENGTH : 20 M •WIDTH :13.5 M •TOTAL HEIGHT : 20 M •LIGHTS HEIGHT: 6 M •ORCHESTRA PIT : 2 STAGE
  • 14. BACKSTAGE : 3 GREEN ROOMS WITH CHANGING ROOMS WORKSHOP AREA REHEARSAL ROOM BACKSTAGE
  • 15. A B C D E F G H •THERE ARE 8 BAYS AND 19 ROWS. •IT CAN ACCOMODATE MAXIMUM OF 984 PERSONS. •WIDTH OF ALLEY-1.5M •A BAY-134 PERSONS •B BAY-136 PERSONS •C BAY-130 PERSONS •D BAY-131 PERSONS •E BAY-131 PERSONS •F BAY-96 PERSONS •G BAY-130 PERSONS •H BAY-96 PERSONS SEATING
  • 16. ELECTRICAL ROOMS MAIN ELECTRIC SUPPLY TO THE ENTIRE BUILDING IS PROVIDED IN THE ELECTRICAL ROOM WHICH IS ADJACENT TO THE MAIN STAGE.
  • 18. A.C SUPPLY AND CATWALK CATWALK AC DUCT ON STAGE AC DUCT ON AUDITORIUM
  • 19. RETURN AIR DUCTS AIR DUCT
  • 20. CATWALK •CATWALKS ARE USED TO: SUSPEND LIGHT AND MICROPHONES DIRECTED AT THE STAGE.
  • 21. CONFERENCE HALLS •2 CONFERENCE HALLS •150 SQ. M EACH •CAPACITY : 200 EACH •TERRACE : 300 SQ. M • •PANTRY PROVIDED.
  • 22. GROUND FLOOR FIRST FLOOR TOILETS Public toilet Private toilet
  • 23. WALL PANELLING •MATERIALS USED : •BOROTIK PANELS ON LOWER HALF •MDF SHEET MATERIALS
  • 24. OBSERVATIONS • RAMPS ARE PROVIDED. • GLASS FACADE TO PROVIDE AMPLE SUNLIGHT AND VENTILATION. • LOBBIES ARE LARGE TO ACCOMMODATE THE HUGE CROWD. • THERE ARE NO CHAIRS OR BENCHES PROVIDED IN THE WAITING AREA.IT IS A HUGE SPACE WITH GOOD LIGHT AND VENTILATION. • DIFFERENT ENTRANCE FOR BACKSTAGE.STORAGE FACILITIES AND TOILETS ARE PROVIDED. • NO QUICK CHANGE. • THERE ARE SMOKE DETECTORS AND SPRINKLERS ON THE CEILING TO DETECT SMOKE.
  • 25. • MERITS- • 1) SPACIOUS WAITING AREAS • 2) SPACE BELOW THE MAIN AUDITORIUM USED AS EXHIBITION AREA FOR PAINTINGS • 3) SEPARATE ENTRY FOR VEHICLES • 4) 8 ENTRIES AND EXITS TO AVOID CROWDING • 5) SERVICE ENTRY IS PROVIDED • 6) PRACTICE HALLS,VIP ROOMS,GUEST ROOMS ARE PROVIDED • DEMERITS- • 1) NEGATIVE SPACES FORMED AT THE BACKSTAGE • 2) THE DISTANCE BETWEEN STAGE AND FIRST ROW IS APPROXIMATELY 1.6 M WHICH IS UNCOMFORTABLE FOR THE FIRST ROW AUDIENCE. • 4) CANTEENS OR REFRESHMENT AREAS ARE NOT PROPERLY MAINTAINED MERITS AND DEMERITS