Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/Hemostasis, Jan 22, 2016
Plasma levels of estimated whole blood viscosity (eWBV) have been increased by endothelial inflam... more Plasma levels of estimated whole blood viscosity (eWBV) have been increased by endothelial inflammation. Because there were no consistent data for assessing the eWBV levels for prediction of cardiovascular event (CVE) in patients with chronic kidney disease (CKD). We aimed to investigate the relationship between plasma eWBV levels and CVEs in patients with CKD. We conducted a prospective, cross-sectional, long-term follow-up study, assessing the relationship between plasma eWBV levels and CVE (either fatal or nonfatal) in patients with newly diagnosed CKD. We also evaluated estimated glomerular filtration rate (eGFR), pentraxin 3 (PTX3), high-sensitivity C-reactive protein (hsCRP), and flow-mediated dilatation (FMD). Study patients were divided into 2 groups: patients with CVE and patients without CVE. The eWBV levels were higher in patients with CVE. Additionally, PTX3 and hsCRP were higher, and FMD and eGFR were lower in patients with CVE compared to those without CVE. According t...
Humidity induced change in the refractive index and thickness of the polyethylene glycol (PEG) co... more Humidity induced change in the refractive index and thickness of the polyethylene glycol (PEG) coatings are in situ investigated for a range from 10 to 95%, using an optical waveguide spectroscopic technique. It is experimentally demonstrated that, upon humidity change, the optical and swelling characteristics of the PEG coatings can be employed to build a plastic fibre optic humidity sensor. The sensing mechanism is based on the humidity induced change in the refractive index of the PEG film, which is directly coated onto a polished segment of a plastic optical fibre with dip-coating method. It is observed that PEG, which is a highly hydrophilic material, shows no monotonic linear response to humidity but gives different characteristics for various ranges of humidity levels both in index of refraction and in thickness. It undergoes a physical phase change from a semi-crystalline structure to a gel one at around 80% relative humidity. At this phase change point, a drastic decrease occurs in the index of refraction as well as a drastic increase in the swelling of the PEG film. In addition, PEG coatings are hydrogenated in a vacuum chamber. It is observed that the hydrogen has a preventing effect on the humidity induced phase change in PEG coatings. Finally, the possibility of using PEG coatings in construction of a real plastic fibre optic humidity sensor is discussed.
Using atomic force microscopy, the height, diameter, and volume of polystyrene particles deposite... more Using atomic force microscopy, the height, diameter, and volume of polystyrene particles deposited on mica from dilute cyclohexane solution at different temperatures are determined. Dimensions exhibit a strong temperature dependence. The heights of the ...
Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/Hemostasis, Jan 22, 2016
Plasma levels of estimated whole blood viscosity (eWBV) have been increased by endothelial inflam... more Plasma levels of estimated whole blood viscosity (eWBV) have been increased by endothelial inflammation. Because there were no consistent data for assessing the eWBV levels for prediction of cardiovascular event (CVE) in patients with chronic kidney disease (CKD). We aimed to investigate the relationship between plasma eWBV levels and CVEs in patients with CKD. We conducted a prospective, cross-sectional, long-term follow-up study, assessing the relationship between plasma eWBV levels and CVE (either fatal or nonfatal) in patients with newly diagnosed CKD. We also evaluated estimated glomerular filtration rate (eGFR), pentraxin 3 (PTX3), high-sensitivity C-reactive protein (hsCRP), and flow-mediated dilatation (FMD). Study patients were divided into 2 groups: patients with CVE and patients without CVE. The eWBV levels were higher in patients with CVE. Additionally, PTX3 and hsCRP were higher, and FMD and eGFR were lower in patients with CVE compared to those without CVE. According t...
Humidity induced change in the refractive index and thickness of the polyethylene glycol (PEG) co... more Humidity induced change in the refractive index and thickness of the polyethylene glycol (PEG) coatings are in situ investigated for a range from 10 to 95%, using an optical waveguide spectroscopic technique. It is experimentally demonstrated that, upon humidity change, the optical and swelling characteristics of the PEG coatings can be employed to build a plastic fibre optic humidity sensor. The sensing mechanism is based on the humidity induced change in the refractive index of the PEG film, which is directly coated onto a polished segment of a plastic optical fibre with dip-coating method. It is observed that PEG, which is a highly hydrophilic material, shows no monotonic linear response to humidity but gives different characteristics for various ranges of humidity levels both in index of refraction and in thickness. It undergoes a physical phase change from a semi-crystalline structure to a gel one at around 80% relative humidity. At this phase change point, a drastic decrease occurs in the index of refraction as well as a drastic increase in the swelling of the PEG film. In addition, PEG coatings are hydrogenated in a vacuum chamber. It is observed that the hydrogen has a preventing effect on the humidity induced phase change in PEG coatings. Finally, the possibility of using PEG coatings in construction of a real plastic fibre optic humidity sensor is discussed.
Using atomic force microscopy, the height, diameter, and volume of polystyrene particles deposite... more Using atomic force microscopy, the height, diameter, and volume of polystyrene particles deposited on mica from dilute cyclohexane solution at different temperatures are determined. Dimensions exhibit a strong temperature dependence. The heights of the ...
Dual left anterior descending (LAD) coronary artery anomaly is traditionally classified as four t... more Dual left anterior descending (LAD) coronary artery anomaly is traditionally classified as four types anomaly by classical coronary angiogram. Nowadays, coronary computed tomographic angiography (CCTA) allows clinicians to understand other variants of dual LAD anomaly. Up to date, 9 types of dual LAD variants detected from not only classical coronary angiogram but also CCTA imaging have been reported. In the present case, we aimed to show a novel dual LAD anomaly, which is demonstrated by CCTA during preoperative evaluation and it has not been previously reported.
Uploads
Thesis Chapters by Mustafa Demir
Papers by Mustafa Demir