Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content

Showing 1–31 of 31 results for author: Bergauer, T

.
  1. arXiv:2407.16710  [pdf, other

    physics.ins-det

    TCAD Simulations of Radiation Damage in 4H-SiC

    Authors: Jürgen Burin, Christopher Hahn, Philipp Gaggl, Andreas Gsponer, Simon Waid, Thomas Bergauer

    Abstract: To increase the scientific output of particle physics experiments, upgrades are underway at all major accelerator facilities to significantly improve the luminosity. Consequently, the solid-state detectors used in the experiments will exhibit more severe radiation-induced damage. To ensure sufficiently long sensor lifetimes, alternative materials to the established silicon sensors, with improved r… ▽ More

    Submitted 22 July, 2024; originally announced July 2024.

    Comments: 4 pages, 4 figures

  2. arXiv:2407.11776  [pdf, other

    physics.ins-det

    TCAD modeling of radiation-induced defects in 4H-SiC diodes

    Authors: Philipp Gaggl, Jürgen Burin, Andreas Gsponer, Simon Emanuel Waid, Richard Thalmeier, Thomas Bergauer

    Abstract: Silicon Carbide (SiC) has several advantageous properties compared to Silicon (Si) that make it an appealing detector material, such as a larger charge carrier saturation velocity, bandgap, and thermal conductivity. While the current understanding of material and model parameters suffices to simulate unirradiated 4H-SiC devices using technical computer-aided design (TCAD), configurations to accura… ▽ More

    Submitted 16 July, 2024; originally announced July 2024.

    Comments: Proceeding of a Poster talk at the 16th Pisa Meeting on Advanced Detectors

  3. arXiv:2406.19421  [pdf, other

    hep-ex physics.ins-det

    The Belle II Detector Upgrades Framework Conceptual Design Report

    Authors: H. Aihara, A. Aloisio, D. P. Auguste, M. Aversano, M. Babeluk, S. Bahinipati, Sw. Banerjee, M. Barbero, J. Baudot, A. Beaubien, F. Becherer, T. Bergauer, F. U. Bernlochner., V. Bertacchi, G. Bertolone, C. Bespin, M. Bessner, S. Bettarini, A. J. Bevan, B. Bhuyan, M. Bona, J. F. Bonis, J. Borah, F. Bosi, R. Boudagga , et al. (186 additional authors not shown)

    Abstract: We describe the planned near-term and potential longer-term upgrades of the Belle II detector at the SuperKEKB electron-positron collider operating at the KEK laboratory in Tsukuba, Japan. These upgrades will allow increasingly sensitive searches for possible new physics beyond the Standard Model in flavor, tau, electroweak and dark sector physics that are both complementary to and competitive wit… ▽ More

    Submitted 4 July, 2024; v1 submitted 26 June, 2024; originally announced June 2024.

    Comments: Editor: F. Forti 170 pages

    Report number: KEK-REPORT-2024-1, BELLE2-REPORT-2024-042

  4. arXiv:2406.11937  [pdf, other

    physics.ins-det hep-ex physics.data-an

    Using graph neural networks to reconstruct charged pion showers in the CMS High Granularity Calorimeter

    Authors: M. Aamir, B. Acar, G. Adamov, T. Adams, C. Adloff, S. Afanasiev, C. Agrawal, C. Agrawal, A. Ahmad, H. A. Ahmed, S. Akbar, N. Akchurin, B. Akgul, B. Akgun, R. O. Akpinar, E. Aktas, A. AlKadhim, V. Alexakhin, J. Alimena, J. Alison, A. Alpana, W. Alshehri, P. Alvarez Dominguez, M. Alyari, C. Amendola , et al. (550 additional authors not shown)

    Abstract: A novel method to reconstruct the energy of hadronic showers in the CMS High Granularity Calorimeter (HGCAL) is presented. The HGCAL is a sampling calorimeter with very fine transverse and longitudinal granularity. The active media are silicon sensors and scintillator tiles readout by SiPMs and the absorbers are a combination of lead and Cu/CuW in the electromagnetic section, and steel in the hadr… ▽ More

    Submitted 30 June, 2024; v1 submitted 17 June, 2024; originally announced June 2024.

    Comments: Prepared for submission to JINST

  5. arXiv:2312.15027  [pdf, ps, other

    physics.med-ph physics.ins-det

    First experimental time-of-flight-based proton radiography using low gain avalanche diodes

    Authors: Felix Ulrich-Pur, Thomas Bergauer, Tetyana Galatyuk, Albert Hirtl, Matthias Kausel, Vadym Kedych, Mladen Kis, Yevhen Kozymka, Wilhelm Krüger, Sergey Linev, Jan Michel, Jerzy Pietraszko, Adrian Rost, Christian Joachim Schmidt, Michael Träger, Michael Traxler

    Abstract: Ion computed tomography (iCT) is an imaging modality for the direct determination of the relative stopping power (RSP) distribution within a patient's body. Usually, this is done by estimating the path and energy loss of ions traversing the scanned volume via a tracking system and a separate residual energy detector. This study, on the other hand, introduces the first experimental study of a novel… ▽ More

    Submitted 22 December, 2023; originally announced December 2023.

    Comments: Preprint submitted to Physics in Medicine and Biology. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it

  6. arXiv:2311.13360  [pdf, other

    physics.ins-det hep-ex

    Upgrade of Belle II Vertex Detector with CMOS Pixel Technology

    Authors: M. Schwickardi, M. Babeluk, M. Barbero, J. Baudot, T. Bergauer, G. Bertolone, S. Bettarini, F. Bosi, P. Breugnon, Y. Buch, G. Casarosa, G. Dujany, C. Finck, F. Forti, A. Frey, A. Himmi, C. Irmler, A. Kumar, C. Marinas, M. Massa, L. Massaccesi, J. Mazzora de Cos, M. Minuti, S. Mondal, P. Pangaud , et al. (5 additional authors not shown)

    Abstract: The Belle II experiment at KEK in Japan considers upgrading its vertex detector system to address the challenges posed by high background levels caused by the increased luminosity of the SuperKEKB collider. One proposal for upgrading the vertex detector aims to install a 5-layer all monolithic pixel vertex detector based on fully depleted CMOS sensors in 2027. The new system will use the OBELIX MA… ▽ More

    Submitted 12 December, 2023; v1 submitted 22 November, 2023; originally announced November 2023.

    Comments: 8 pages, 8 figures, Proceedings for 24th international Workshop on Radiation Imaging Detectors,25-29 JUNE 20233 Oslo

  7. arXiv:2311.08960  [pdf, other

    physics.med-ph

    Pulsed RF Knock-Out Extraction: A Potential Enabler for FLASH Hadrontherapy in the Bragg Peak

    Authors: Simon Waid, Andreas Gsponer, Elisabeth Renner, Claus Schmitzer, Florian Kühteubl, Clara Becker, Jürgen Burin, Philipp Gaggl, Dale Prokopovich, Thomas Bergauer

    Abstract: One challenge on the path to delivering FLASH-compatible beams with a synchrotron is facilitating an accurate dose-control for the required ultra-high dose rates. We propose the use of pulsed RFKO extraction instead of continuous beam delivery as a way to control the dose delivered per Voxel. In a first feasibility test dose rates in pulses of up to 600 Gy/s were observed, while the granularity at… ▽ More

    Submitted 19 March, 2024; v1 submitted 15 November, 2023; originally announced November 2023.

  8. arXiv:2311.03902  [pdf, other

    physics.ins-det

    Measurement of the electron-hole pair creation energy in a 4H-SiC p-n diode

    Authors: Andreas Gsponer, Matthias Knopf, Philipp Gaggl, Jürgen Burin, Simon Waid, Thomas Bergauer

    Abstract: For 4H silicon carbide (4H-SiC), the values for the electron-hole pair creation energy $ε_{\text{i}}$ published in the literature vary significantly. This work presents an experimental determination of $ε_{\text{i}}$ using $50$ $μ$m 4H-SiC p-n diodes designed for particle detection in high-energy physics. The detector response was measured for $α$ particles between 4.2 MeV and 5.6 MeV for 4H-SiC a… ▽ More

    Submitted 1 April, 2024; v1 submitted 7 November, 2023; originally announced November 2023.

    Comments: Revision prepared for submission to NIM A

  9. arXiv:2310.14996  [pdf, other

    physics.ins-det

    SiC Based Beam Monitoring System for Particle Rates from kHz to GHz

    Authors: Simon Waid, Andreas Gsponer, Jürgen Maier, Philipp Gaggl, Richard Thalmeier, Thomas Bergauer

    Abstract: The extremely low dark current of silicon carbide (SiC) detectors, even after high-fluence irradiation, was utilized to develop a beam monitoring system for a wide range of particle rates, i.e., from the kHz to the GHz regime. The system is completely built from off-the-shelve components and is focused on compactness and simple deployment. Beam tests using a 50 um thick SiC detector reveal, that f… ▽ More

    Submitted 19 March, 2024; v1 submitted 23 October, 2023; originally announced October 2023.

  10. arXiv:2310.02047  [pdf, other

    physics.ins-det

    Neutron Radiation induced Effects in 4H-SiC PiN Diodes

    Authors: Andreas Gsponer, Philipp Gaggl, Jürgen Maier, Richard Thalmeier, Simon Emanuel Waid, Thomas Bergauer

    Abstract: Silicon carbide (SiC) is a wide band gap semiconductor and an attractive candidate for applications in harsh environments such as space, fusion, or future high luminosity colliders. Due to the large band gap, the leakage currents in SiC devices are extremely small, even after irradiation to very high fluences, enabling operation without cooling and at high temperatures. This study investigates the… ▽ More

    Submitted 3 October, 2023; originally announced October 2023.

    Comments: 9 pages, 6 figures, to be published in the Proceedings Section of Journal of Instrumentation (JINST) as a proceeding of iWoRiD2023

  11. arXiv:2211.11244  [pdf, other

    physics.ins-det hep-ex

    RD50-MPW3: A fully monolithic digital CMOS sensor for future tracking detectors

    Authors: Patrick Sieberer, Chenfan Zhang, Thomas Bergauer, Raimon Casanova Mohr, Christian Irmler, Nissar Karim, Jose Mazorra de Cos, Bernhard Pilsl, Eva Vilella

    Abstract: The CERN-RD50 CMOS working group develops the RD50-MPWseries of monolithic high-voltage CMOS pixel sensors for potential use in future high luminosity experiments such as the HL-LHC and FCC-hh. In this contribution, the design of the latest prototype in this series, RD50-MPW3, is presented. An overview of its pixel matrix and digital readout periphery is given, with discussion of the new structure… ▽ More

    Submitted 17 January, 2023; v1 submitted 21 November, 2022; originally announced November 2022.

    Report number: 2023_JINST_18_C02061

  12. arXiv:2211.04740  [pdf, other

    physics.ins-det

    Performance of the CMS High Granularity Calorimeter prototype to charged pion beams of 20$-$300 GeV/c

    Authors: B. Acar, G. Adamov, C. Adloff, S. Afanasiev, N. Akchurin, B. Akgün, M. Alhusseini, J. Alison, J. P. Figueiredo de sa Sousa de Almeida, P. G. Dias de Almeida, A. Alpana, M. Alyari, I. Andreev, U. Aras, P. Aspell, I. O. Atakisi, O. Bach, A. Baden, G. Bakas, A. Bakshi, S. Banerjee, P. DeBarbaro, P. Bargassa, D. Barney, F. Beaudette , et al. (435 additional authors not shown)

    Abstract: The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing med… ▽ More

    Submitted 27 May, 2023; v1 submitted 9 November, 2022; originally announced November 2022.

    Comments: Accepted for publication by JINST

  13. Performance of neutron-irradiated 4H-Silicon Carbide diodes subjected to Alpha radiation

    Authors: Philipp Gaggl, Andreas Gsponer, Richard Thalmeier, Simon Waid, Giulio Pellegrini, Philippe Godignon, Joan Marc Rafí, Thomas Bergauer

    Abstract: The unique electrical and material properties of 4H-silicon-carbide (4H-SiC) make it a promising candidate material for high rate particle detectors. In contrast to the ubiquitously used silicon (Si), 4H-SiC offers a higher carrier saturation velocity and larger breakdown voltage, enabling a high intrinsic time resolution and mitigating pile-up effects. Additionally, as radiation hardness requirem… ▽ More

    Submitted 9 December, 2022; v1 submitted 16 October, 2022; originally announced October 2022.

    Comments: 10 pages (8 without references), 6 figures, 1 table, to be published in the Proceedings Section of Journal of Instrumentation (JINST) as a proceeding of iWoRiD2022

  14. arXiv:2209.13676  [pdf, other

    physics.med-ph physics.ins-det

    Novel ion imaging concept based on time-of-flight measurements with low gain avalanche detectors

    Authors: Felix Ulrich-Pur, Thomas Bergauer, Albert Hirtl, Christian Irmler, Stefanie Kaser, Florian Pitters, Simon Rit

    Abstract: Treatment planning in ion beam therapy requires accurate knowledge of the relative stopping power (RSP) distribution within the patient. Currently, RSP maps are obtained via conventional x-ray computed tomography (CT) by converting the measured attenuation coefficients of photons into RSP values for ions. Alternatively, to avoid conversion errors that are inherent to this method, ion computed tomo… ▽ More

    Submitted 27 September, 2022; originally announced September 2022.

  15. Readout system and testbeam results of the RD50-MPW2 HV-CMOS pixel chip

    Authors: Patrick Sieberer, Thomas Bergauer, Klemens Floeckner, Christian Irmler, Helmut Steininger

    Abstract: The RD50-CMOS group aims to design and study High Voltage CMOS (HVCMOS) chips for use in a high radiation environment. Currently, measurements are performed on RD50-MPW2 chip, the second prototype developed by this group. The active matrix of the prototype consists of 8x8 pixels with analog front end. Details of the analog front end and simulations have been already published earlier. This contrib… ▽ More

    Submitted 9 December, 2022; v1 submitted 21 January, 2022; originally announced January 2022.

    Comments: Published under licence in Journal of Physics: Conference Series by IOP Publishing Ltd. CC-BY Content from this work may be used under the terms of the Creative Commons Attribution 4.0 International licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI

    Journal ref: Journal of Physics: Conference Series. Volume 2374. 2022. 012096

  16. arXiv:2112.02429  [pdf, other

    physics.ins-det hep-ex

    4H-Silicon Carbide as particle detector for high-intensity ion beams

    Authors: Manuel Christanell, Maximilian Tomaschek, Thomas Bergauer

    Abstract: In ion cancer therapy, high-intensity ion beams are used to treat tumors by taking advantage of the Bragg-Peak. Typical ion therapy centers use particle rates up to $10^{10}$ ions/second for treatment. On the other hand, such intensities are often too high when using these beamlines for particle physics experiments or as a test-beam environment in general. The project presented here aims to develo… ▽ More

    Submitted 4 December, 2021; originally announced December 2021.

    Comments: proceedings of the 22nd International Workshop on Radiation Imaging Detectors iWorid

    Journal ref: JINST 143P_0921 (2021)

  17. arXiv:2111.06855  [pdf, other

    physics.ins-det hep-ex

    Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20-300 GeV positrons

    Authors: B. Acar, G. Adamov, C. Adloff, S. Afanasiev, N. Akchurin, B. Akgün, F. Alam Khan, M. Alhusseini, J. Alison, A. Alpana, G. Altopp, M. Alyari, S. An, S. Anagul, I. Andreev, P. Aspell, I. O. Atakisi, O. Bach, A. Baden, G. Bakas, A. Bakshi, S. Bannerjee, P. Bargassa, D. Barney, F. Beaudette , et al. (364 additional authors not shown)

    Abstract: The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glu… ▽ More

    Submitted 31 March, 2022; v1 submitted 12 November, 2021; originally announced November 2021.

  18. Feasibility study of a proton CT system based on 4D-tracking and residual energy determination via time-of-flight

    Authors: Felix Ulrich-Pur, Thomas Bergauer, Alexander Burker, Albert Hirtl, Christian Irmler, Stefanie Kaser, Florian Pitters, Simon Rit

    Abstract: For dose calculations in ion beam therapy, it is vital to accurately determine the relative stopping power (RSP) distribution within the treated volume. Currently, RSP values are extrapolated from Hounsfield units (HU), measured with x-ray computed tomography (CT), which entails RSP inaccuracies due to conversion errors. A suitable method to improve the treatment plan accuracy is proton computed t… ▽ More

    Submitted 10 September, 2021; originally announced September 2021.

    Comments: Preprint submitted to Physics in Medicine and Biology. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it

  19. A Proton Computed Tomography Demonstrator for Stopping Power Measurements

    Authors: Felix Ulrich-Pur, Thomas Bergauer, Alexander Burker, Albert Hirtl, Christian Irmler, Stefanie Kaser, Florian Pitters

    Abstract: Particle therapy is an established method to treat deep-seated tumours using accelerator-produced ion beams. For treatment planning, the precise knowledge of the relative stopping power (RSP) within the patient is vital. Conversion errors from x-ray computed tomography (CT) measurements to RSP introduce uncertainties in the applied dose distribution. Using a proton computed tomography (pCT) system… ▽ More

    Submitted 24 June, 2021; originally announced June 2021.

    Comments: Preprint submitted to the open-access Journal of Physics: Conference Series. (TIPP2021 conference proceedings). IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it

  20. arXiv:2102.06240  [pdf, other

    physics.acc-ph physics.med-ph

    Commissioning of low particle flux for proton beams at MedAustron

    Authors: Felix Ulrich-Pur, Laurids Adler, Thomas Bergauer, Alexander Burker, Andrea De Franco, Greta Guidoboni, Albert Hirtl, Christian Irmler, Stefanie Kaser, Sebastian Nowak, Florian Pitters, Mauro Pivi, Dale Prokopovich, Claus Schmitzer, Alexander Wastl

    Abstract: MedAustron is a synchrotron-based particle therapy centre located in Wiener Neustadt, Austria. It features three irradiation rooms for particle therapy, where proton beams with energies up to 252.7 MeV and carbon ions of up to 402.8 MeV/u are available for cancer treatment. In addition to the treatment rooms, MedAustron features a unique beamline exclusively for non-clinical research (NCR). This r… ▽ More

    Submitted 27 May, 2021; v1 submitted 11 February, 2021; originally announced February 2021.

    Comments: Preprint submitted to NIM A (first revision)

  21. arXiv:2012.06336  [pdf, other

    physics.ins-det hep-ex

    Construction and commissioning of CMS CE prototype silicon modules

    Authors: B. Acar, G. Adamov, C. Adloff, S. Afanasiev, N. Akchurin, B. Akgün, M. Alhusseini, J. Alison, G. Altopp, M. Alyari, S. An, S. Anagul, I. Andreev, M. Andrews, P. Aspell, I. A. Atakisi, O. Bach, A. Baden, G. Bakas, A. Bakshi, P. Bargassa, D. Barney, E. Becheva, P. Behera, A. Belloni , et al. (307 additional authors not shown)

    Abstract: As part of its HL-LHC upgrade program, the CMS Collaboration is developing a High Granularity Calorimeter (CE) to replace the existing endcap calorimeters. The CE is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic (CE-E) and hadronic (CE-H) compartments. The calorimeter will be built with $\sim$30,000 hexagonal silicon modules. Prototype modul… ▽ More

    Submitted 10 December, 2020; originally announced December 2020.

    Comments: 35 pages, submitted to JINST

  22. arXiv:2012.03876  [pdf, other

    physics.ins-det hep-ex

    The DAQ system of the 12,000 Channel CMS High Granularity Calorimeter Prototype

    Authors: B. Acar, G. Adamov, C. Adloff, S. Afanasiev, N. Akchurin, B. Akgün, M. Alhusseini, J. Alison, G. Altopp, M. Alyari, S. An, S. Anagul, I. Andreev, M. Andrews, P. Aspell, I. A. Atakisi, O. Bach, A. Baden, G. Bakas, A. Bakshi, P. Bargassa, D. Barney, E. Becheva, P. Behera, A. Belloni , et al. (307 additional authors not shown)

    Abstract: The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endca… ▽ More

    Submitted 8 December, 2020; v1 submitted 7 December, 2020; originally announced December 2020.

  23. arXiv:2008.08422  [pdf, other

    physics.med-ph physics.ins-det

    Single particle tracking uncertainties in ion imaging

    Authors: A. Burker, T. Bergauer, A. Hirtl, C. Irmler, S. Kaser, B. Knäusl, F. Pitters, F. Ulrich-Pur

    Abstract: An extensive comparison of the path uncertainty in single particle tracking systems for ion imaging was carried out based on Monte Carlo simulations. The spatial resolution as function of system parameters such as geometry, detector properties and the energy of proton and helium beams was investigated to serve as a guideline for hardware developments. Primary particle paths were sampled within a… ▽ More

    Submitted 22 February, 2021; v1 submitted 19 August, 2020; originally announced August 2020.

    Comments: 19 pages, 6 figures, submitted to Phys. Med. Biol

  24. Charge Collection and Electrical Characterization of Neutron Irradiated Silicon Pad Detectors for the CMS High Granularity Calorimeter

    Authors: N. Akchurin, P. Almeida, G. Altopp, M. Alyari, T. Bergauer, E. Brondolin, B. Burkle, W. D. Frey, Z. Gecse, U. Heintz, N. Hinton, V. Kuryatkov, R. Lipton, M. Mannelli, T. Mengke, P. Paulitsch, T. Peltola, F. Pitters, E. Sicking, E. Spencer, M. Tripathi, M. Vicente Barreto Pinto, J. Voelker, Z. Wang, R. Yohay

    Abstract: The replacement of the existing endcap calorimeter in the Compact Muon Solenoid (CMS) detector for the high-luminosity LHC (HL-LHC), scheduled for 2027, will be a high granularity calorimeter. It will provide detailed position, energy, and timing information on electromagnetic and hadronic showers in the immense pileup of the HL-LHC. The High Granularity Calorimeter (HGCAL) will use 120-, 200-, an… ▽ More

    Submitted 4 August, 2020; v1 submitted 16 May, 2020; originally announced May 2020.

    Comments: 36 pages, 34 figures

  25. arXiv:2003.00115  [pdf, other

    physics.ins-det physics.med-ph

    Imaging with protons at MedAustron

    Authors: F. Ulrich-Pur, T. Bergauer, A. Burker, S. Hatamikia, A. Hirtl, C. Irmler, S. Kaser, P. Paulitsch, F. Pitters, V. Teufelhart

    Abstract: Ion beam therapy has become a frequently applied form of cancer therapy over the last years. The advantage of ion beam therapy over conventional radiotherapy using photons is the strongly localized dose deposition, leading to a reduction of dose applied to surrounding healthy tissue. Currently, treatment planning for proton therapy is based on X-ray computed tomography, which entails certain sourc… ▽ More

    Submitted 15 July, 2020; v1 submitted 28 February, 2020; originally announced March 2020.

    Comments: 7 pages, 11 figures, proceedings of the "HSTD12: 12th International "Hiroshima" Symposium on the Development and Application of Semiconductor Tracking Detectors (HSTD12)", 14-18 Dec 2019, Hiroshima (Japan), to be submitted to Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

  26. Trapping in irradiated p-on-n silicon sensors at fluences anticipated at the HL-LHC outer tracker

    Authors: W. Adam, T. Bergauer, M. Dragicevic, M. Friedl, R. Fruehwirth, M. Hoch, J. Hrubec, M. Krammer, W. Treberspurg, W. Waltenberger, S. Alderweireldt, W. Beaumont, X. Janssen, S. Luyckx, P. Van Mechelen, N. Van Remortel, A. Van Spilbeeck, P. Barria, C. Caillol, B. Clerbaux, G. De Lentdecker, D. Dobur, L. Favart, A. Grebenyuk, Th. Lenzi , et al. (663 additional authors not shown)

    Abstract: The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 $μ$m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to $3 \cdot 10^{15}$ neq/cm$^2$. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determi… ▽ More

    Submitted 7 May, 2015; originally announced May 2015.

    Journal ref: 2016 JINST 11 P04023

  27. arXiv:1411.4413  [pdf, other

    hep-ex hep-ph

    Observation of the rare $B^0_s\toμ^+μ^-$ decay from the combined analysis of CMS and LHCb data

    Authors: The CMS, LHCb Collaborations, :, V. Khachatryan, A. M. Sirunyan, A. Tumasyan, W. Adam, T. Bergauer, M. Dragicevic, J. Erö, M. Friedl, R. Frühwirth, V. M. Ghete, C. Hartl, N. Hörmann, J. Hrubec, M. Jeitler, W. Kiesenhofer, V. Knünz, M. Krammer, I. Krätschmer, D. Liko, I. Mikulec, D. Rabady, B. Rahbaran , et al. (2807 additional authors not shown)

    Abstract: A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six sta… ▽ More

    Submitted 17 August, 2015; v1 submitted 17 November, 2014; originally announced November 2014.

    Comments: Correspondence should be addressed to cms-and-lhcb-publication-committees@cern.ch

    Report number: CERN-PH-EP-2014-220, CMS-BPH-13-007, LHCb-PAPER-2014-049

    Journal ref: Nature 522, 68-72 (04 June 2015)

  28. arXiv:1201.4657  [pdf

    physics.ins-det hep-ex

    Infrastructure for Detector Research and Development towards the International Linear Collider

    Authors: J. Aguilar, P. Ambalathankandy, T. Fiutowski, M. Idzik, Sz. Kulis, D. Przyborowski, K. Swientek, A. Bamberger, M. Köhli, M. Lupberger, U. Renz, M. Schumacher, Andreas Zwerger, A. Calderone, D. G. Cussans, H. F. Heath, S. Mandry, R. F. Page, J. J. Velthuis, D. Attié, D. Calvet, P. Colas, X. Coppolani, Y. Degerli, E. Delagnes , et al. (252 additional authors not shown)

    Abstract: The EUDET-project was launched to create an infrastructure for developing and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infras… ▽ More

    Submitted 23 January, 2012; originally announced January 2012.

    Comments: 54 pages, 48 pictures

  29. arXiv:1011.0352  [pdf

    physics.ins-det hep-ex

    Belle II Technical Design Report

    Authors: T. Abe, I. Adachi, K. Adamczyk, S. Ahn, H. Aihara, K. Akai, M. Aloi, L. Andricek, K. Aoki, Y. Arai, A. Arefiev, K. Arinstein, Y. Arita, D. M. Asner, V. Aulchenko, T. Aushev, T. Aziz, A. M. Bakich, V. Balagura, Y. Ban, E. Barberio, T. Barvich, K. Belous, T. Bergauer, V. Bhardwaj , et al. (387 additional authors not shown)

    Abstract: The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been pr… ▽ More

    Submitted 1 November, 2010; originally announced November 2010.

    Comments: Edited by: Z. Doležal and S. Uno

    Report number: KEK Report 2010-1

  30. arXiv:0901.4903  [pdf, other

    physics.ins-det hep-ex

    Resolution Studies on Silicon Strip Sensors with fine Pitch

    Authors: S. Haensel, T. Bergauer, Z. Dolezal, M. Dragicevic, Z. Drasal, M. Friedl, J. Hrubec, C. Irmler, W. Kiesenhofer, M. Krammer, P. Kvasnicka

    Abstract: In June 2008 single-sided silicon strip sensors with 50 $μ$m readout pitch were tested in a highly energetic pion beam at the SPS at CERN. The purpose of the test was to evaluate characteristic detector properties by varying the strip width and the number of intermediate strips. The experimental setup and first results for the spatial resolution are discussed.

    Submitted 19 February, 2009; v1 submitted 30 January, 2009; originally announced January 2009.

    Comments: proceeding of the International Linear Collider Workshop 2008 (LCWS08); corrected typos, added reference for section 6

  31. arXiv:0901.4815  [pdf, other

    physics.ins-det

    Silicon Detectors for the Large Prototype TPC test setup at DESY

    Authors: S. Haensel, T. Bergauer, M. Dragicevic, J. Hrubec, M. Krammer, A. Dierlamm, T. Barvich, F. Hartmann, Th. Müller

    Abstract: The Linear Collider TPC collaboration constructed a Large Prototype TPC (LPTPC) which is now installed at the EUDET facility, in DESY. The SiLC-collaboration (Silicon for the Linear Collider) will install position sensitive silicon strip sensors outside the field cage of the LPTPC, to provide precise tracking information. The data acquisition system (DAQ) is an adapted CMS readout system. The si… ▽ More

    Submitted 19 February, 2009; v1 submitted 30 January, 2009; originally announced January 2009.

    Comments: proceeding of the International Linear Collider Workshop 2008 (LCWS08); corrected typos and added reference for section 1