-
Characterization of Charge Spreading and Gain of Encapsulated Resistive Micromegas Detectors for the Upgrade of the T2K Near Detector Time Projection Chambers
Authors:
D. Attie,
O. Ballester,
M. Batkiewicz-Kwasnia,
P. Billoir,
A. Blondel,
S. Bolognesi,
R. Boullon,
D. Calvet,
M. P. Casado,
M. G. Catanesi,
M. Cicerchia,
G. Cogo,
P. Colas,
G. Collazuol,
D. D Ago,
C. Dalmazzon,
T. Daret,
A. Delbart,
A. De Lorenzis,
R. de Oliveira,
S. Dolan,
K. Dygnarowiczi,
J. Dumarchez,
S. Emery-Schren,
A. Ershova
, et al. (70 additional authors not shown)
Abstract:
An upgrade of the near detector of the T2K long baseline neutrino oscillation experiment is currently being conducted. This upgrade will include two new Time Projection Chambers, each equipped with 16 charge readout resistive Micromegas modules. A procedure to validate the performance of the detectors at different stages of production has been developed and implemented to ensure a proper and relia…
▽ More
An upgrade of the near detector of the T2K long baseline neutrino oscillation experiment is currently being conducted. This upgrade will include two new Time Projection Chambers, each equipped with 16 charge readout resistive Micromegas modules. A procedure to validate the performance of the detectors at different stages of production has been developed and implemented to ensure a proper and reliable operation of the detectors once installed. A dedicated X-ray test bench is used to characterize the detectors by scanning each pad individually and to precisely measure the uniformity of the gain and the deposited energy resolution over the pad plane. An energy resolution of about 10% is obtained. A detailed physical model has been developed to describe the charge dispersion phenomena in the resistive Micromegas anode. The detailed physical description includes initial ionization, electron drift, diffusion effects and the readout electronics effects. The model provides an excellent characterization of the charge spreading of the experimental measurements and allowed the simultaneous extraction of gain and RC information of the modules.
△ Less
Submitted 8 March, 2023;
originally announced March 2023.
-
Analysis of test beam data taken with a prototype of TPC with resistive Micromegas for the T2K Near Detector upgrade
Authors:
D. Attié,
O. Ballester,
M. Batkiewicz-Kwasniak,
P. Billoir,
A. Blanchet,
A. Blondel,
S. Bolognesi,
R. Boullon,
D. Calvet,
M. P. Casado,
M. G. Catanesi,
M. Cicerchia,
G. Cogo,
P. Colas,
G. Collazuol,
C. Dalmazzone,
T. Daret,
A. Delbart,
A. De Lorenzis,
S. Dolan,
K. Dygnarowicz,
J. Dumarchez,
S. Emery-Schrenk,
A. Ershova,
G. Eurin
, et al. (59 additional authors not shown)
Abstract:
In this paper we describe the performance of a prototype of the High Angle Time Projection Chambers (HA-TPCs) that are being produced for the Near Detector (ND280) upgrade of the T2K experiment. The two HA-TPCs of ND280 will be instrumented with eight Encapsulated Resistive Anode Micromegas (ERAM) on each endplate, thus constituting in total 32 ERAMs. This innovative technique allows the detection…
▽ More
In this paper we describe the performance of a prototype of the High Angle Time Projection Chambers (HA-TPCs) that are being produced for the Near Detector (ND280) upgrade of the T2K experiment. The two HA-TPCs of ND280 will be instrumented with eight Encapsulated Resistive Anode Micromegas (ERAM) on each endplate, thus constituting in total 32 ERAMs. This innovative technique allows the detection of the charge emitted by ionization electrons over several pads, improving the determination of the track position. The TPC prototype has been equipped with the first ERAM module produced for T2K and with the HA-TPC readout electronics chain and it has been exposed to the DESY Test Beam in order to measure spatial and dE/dx resolution. In this paper we characterize the performances of the ERAM and, for the first time, we compare them with a newly developed simulation of the detector response. Spatial resolution better than 800 ${μ\rm m}$ and dE/dx resolution better than 10% are observed for all the incident angles and for all the drift distances of interest. All the main features of the data are correctly reproduced by the simulation and these performances fully fulfill the requirements for the HA-TPCs of T2K.
△ Less
Submitted 16 May, 2023; v1 submitted 13 December, 2022;
originally announced December 2022.
-
Double-hit separation and dE/dx resolution of a time projection chamber with GEM readout
Authors:
Yumi Aoki,
David Attié,
Ties Behnke,
Alain Bellerive,
Oleg Bezshyyko,
Deb Bhattacharya Sankar,
Purba Bhattacharya,
Sudeb Bhattacharya,
Yue Chang,
Paul Colas,
Gilles De Lentdecker,
Klaus Dehmelt,
Klaus Desch,
Ralf Diener,
Madhu Dixit,
Ulrich Einhaus,
Oleksiy Fedorchuk,
Ivor Fleck,
Keisuke Fujii,
Takahiro Fusayasu,
Serguei Ganjour,
Philippe Gros,
Peter Hayman,
Katsumasa Ikematsu,
Leif Jönsson
, et al. (46 additional authors not shown)
Abstract:
A time projection chamber (TPC) with micropattern gaseous detector (MPGD) readout is investigated as main tracking device of the International Large Detector (ILD) concept at the planned International Linear Collider (ILC). A prototype TPC equipped with a triple gas electron multiplier (GEM) readout has been built and operated in an electron test beam. The TPC was placed in a 1 T solenoidal field…
▽ More
A time projection chamber (TPC) with micropattern gaseous detector (MPGD) readout is investigated as main tracking device of the International Large Detector (ILD) concept at the planned International Linear Collider (ILC). A prototype TPC equipped with a triple gas electron multiplier (GEM) readout has been built and operated in an electron test beam. The TPC was placed in a 1 T solenoidal field at the DESY II Test Beam Facility, which provides an electron beam up to 6 GeV/c. The performance of the readout modules, in particular the spatial point resolution, is determined and compared to earlier tests. New studies are presented with first results on the separation of close-by tracks and the capability of the system to measure the specific energy loss dE/dx. This is complemented by a simulation study on the optimization of the readout granularity to improve particle identification by dE/dx.
△ Less
Submitted 25 November, 2022; v1 submitted 24 May, 2022;
originally announced May 2022.
-
The International Linear Collider: Report to Snowmass 2021
Authors:
Alexander Aryshev,
Ties Behnke,
Mikael Berggren,
James Brau,
Nathaniel Craig,
Ayres Freitas,
Frank Gaede,
Spencer Gessner,
Stefania Gori,
Christophe Grojean,
Sven Heinemeyer,
Daniel Jeans,
Katja Kruger,
Benno List,
Jenny List,
Zhen Liu,
Shinichiro Michizono,
David W. Miller,
Ian Moult,
Hitoshi Murayama,
Tatsuya Nakada,
Emilio Nanni,
Mihoko Nojiri,
Hasan Padamsee,
Maxim Perelstein
, et al. (487 additional authors not shown)
Abstract:
The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This docu…
▽ More
The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This document brings the story of the ILC up to date, emphasizing its strong physics motivation, its readiness for construction, and the opportunity it presents to the US and the global particle physics community.
△ Less
Submitted 16 January, 2023; v1 submitted 14 March, 2022;
originally announced March 2022.
-
MPGDs for TPCs at future lepton colliders
Authors:
Alain Bellerive,
Jochen Kaminski,
Peter M. Lewis,
Paul Colas,
Ralf Diener,
Peter Kluit,
Ronald Dean Settles,
Jan Timmermans,
Maxim Titov,
Andreas Loschcke Centeno,
Christian Wessel,
Oskar Hartbrich,
Sven Vahsen,
Carlos Marinas,
Huiron Qi,
Zhiyong Zhang
Abstract:
This submission will focus on advancements and advantages of Micro Pattern Gas Detector (MPGD) technologies and their applications to the construction of a dedicated Time Projection Chamber (TPC) that can serve as an excellent main tracker for any multipurpose detector that can be foreseen to operate at a future lepton collider. The first portion of the report will be the executive summary. It wil…
▽ More
This submission will focus on advancements and advantages of Micro Pattern Gas Detector (MPGD) technologies and their applications to the construction of a dedicated Time Projection Chamber (TPC) that can serve as an excellent main tracker for any multipurpose detector that can be foreseen to operate at a future lepton collider. The first portion of the report will be the executive summary. It will be followed by sections detailing the applications of MPGDs specifically to the construction of the LCTPC for the ILD at ILC, for a possible upgrade of the Belle II detector at SuperKEKB and for the design of a TPC for a detector at CEPC. MPGD technologies offer synergies with other detector R&D and several application domains; a few examples will be provided in the context of the ongoing Snowmass long range planning exercise in the USA. Links to industrial partnership and work with institutions in the USA will be highlighted when appropriate.
△ Less
Submitted 15 March, 2022; v1 submitted 11 March, 2022;
originally announced March 2022.
-
Characterization of resistive Micromegas detectors for the upgrade of the T2K Near Detector Time Projection Chambers
Authors:
D. Attié,
M. Batkiewicz-Kwasniak,
P. Billoir,
A. Blanchet,
A. Blondel,
S. Bolognesi,
D. Calvet,
M. G. Catanesi,
M. Cicerchia,
G. Cogo,
P. Colas,
G. Collazuol,
A. Delbart,
J. Dumarchez,
S. Emery-Schrenk,
M. Feltre,
C. Giganti,
F. Gramegna,
M. Grassi,
M. Guigue,
P. Hamacher-Baumann,
S. Hassani,
F. Iacob,
C. Jesús-Valls,
R. Kurjata
, et al. (36 additional authors not shown)
Abstract:
The second phase of the T2K experiment is expected to start data taking in autumn 2022. An upgrade of the Near Detector (ND280) is under development and includes the construction of two new Time Projection Chambers called High-Angle TPC (HA-TPC). The two endplates of these TPCs will be paved with eight Micromegas type charge readout modules. The Micromegas detector charge amplification structure u…
▽ More
The second phase of the T2K experiment is expected to start data taking in autumn 2022. An upgrade of the Near Detector (ND280) is under development and includes the construction of two new Time Projection Chambers called High-Angle TPC (HA-TPC). The two endplates of these TPCs will be paved with eight Micromegas type charge readout modules. The Micromegas detector charge amplification structure uses a resistive anode to spread the charges over several pads to improve the space point resolution. This innovative technique is combined with the bulk-Micromegas technology to compose the "Encapsulated Resistive Anode Micromegas" detector. A prototype has been designed, built and exposed to an electron beam at the DESY II test beam facility.
The data have been used to characterize the charge spreading and to produce a RC map. Spatial resolution better than 600 $μ$m and energy resolution better than 9% are obtained for all incident angles. These performances fulfil the requirements for the upgrade of the ND280 TPC.
△ Less
Submitted 23 June, 2021;
originally announced June 2021.
-
Numerical study of track distortion in the Large Prototype TPC with end-plate based on bulk Micromegas
Authors:
Deb Sankar Bhattacharya,
Purba Bhattacharya,
Supratik Mukhopadhyay,
Nayana Majumdar,
Sandip Sarkar,
Sudeb Bhattacharya,
Paul Colas,
David Attié,
Serguei Ganjour,
Aparajita Bhattacharya
Abstract:
The present $\mathrm{R}\&\mathrm{D}$ activities for the International Large Detector Time Projection Chamber (ILD-TPC) concern the adoption of the micro pattern devices for the gaseous amplification stage. Seven Micromegas modules which are commissioned on the end-plate of a Large Prototype TPC (LPTPC) at DESY, were tested with a 5 GeV electron beam, under a 1 T magnetic field. During experiments,…
▽ More
The present $\mathrm{R}\&\mathrm{D}$ activities for the International Large Detector Time Projection Chamber (ILD-TPC) concern the adoption of the micro pattern devices for the gaseous amplification stage. Seven Micromegas modules which are commissioned on the end-plate of a Large Prototype TPC (LPTPC) at DESY, were tested with a 5 GeV electron beam, under a 1 T magnetic field. During experiments, reduced signal sensitivity as well as distortion in the reconstructed track was observed at the boundaries of these modules. Electrostatic field inhomogeneity near the module boundaries was considered to be the possible major reason behind these observations. In the present work, this hypothesis has been explored using the Garfield simulation framework. It has been possible to contain the computational complexity of the problem with suitable simplifications. Qualitative and quantitative agreements with experimental results have been achieved. Possibility of mitigating the problems has been proposed using the same simulation framework.
△ Less
Submitted 28 May, 2020; v1 submitted 20 April, 2020;
originally announced April 2020.
-
Performances of a resistive MicroMegas module for the Time Projection Chambers of the T2K Near Detector upgrade
Authors:
D. Attie,
M. Batkiewicz-Kwasniak,
J. Boix,
S. Bolognesi,
S. Bordoni,
D. Calvet,
M. G. Catanesi,
M. Cicerchia,
G. Cogo,
P. Colas,
G. Collazuol,
A. Dabrowska,
A. Delbart,
J. Dumarchez,
S. Emery-Schrenk,
C. Giganti,
F. Gramegna,
M. Guigue,
P. Hamacher-Baumann,
F. Iacob,
C. Jesus-Valls,
U. Kosed,
R. Kurjataj,
N. Lacalamita,
M. Lamoureux
, et al. (31 additional authors not shown)
Abstract:
An upgrade of the Near Detector of the T2K long baseline neutrino oscillation experiment, ND280, has been proposed. This upgrade will include two new Time Projection Chambers, each equipped with 16 resistive MicroMegas modules for gas amplification. A first prototype of resistive MicroMegas has been designed, built, installed in the HARP field cage, and exposed to a beam of charged particles at CE…
▽ More
An upgrade of the Near Detector of the T2K long baseline neutrino oscillation experiment, ND280, has been proposed. This upgrade will include two new Time Projection Chambers, each equipped with 16 resistive MicroMegas modules for gas amplification. A first prototype of resistive MicroMegas has been designed, built, installed in the HARP field cage, and exposed to a beam of charged particles at CERN. The data have been used to characterize the performances of the resistive MicroMegas module. A spatial resolution of 300 $μm$ and a deposited energy resolution of 9% were observed for horizontal electrons crossing the TPCs at 30 cm from the anode. Such performances fully satisfy the requirements for the upgrade of the ND280 TPC.
△ Less
Submitted 9 December, 2019; v1 submitted 16 July, 2019;
originally announced July 2019.
-
The International Linear Collider. A Global Project
Authors:
Hiroaki Aihara,
Jonathan Bagger,
Philip Bambade,
Barry Barish,
Ties Behnke,
Alain Bellerive,
Mikael Berggren,
James Brau,
Martin Breidenbach,
Ivanka Bozovic-Jelisavcic,
Philip Burrows,
Massimo Caccia,
Paul Colas,
Dmitri Denisov,
Gerald Eigen,
Lyn Evans,
Angeles Faus-Golfe,
Brian Foster,
Keisuke Fujii,
Juan Fuster,
Frank Gaede,
Jie Gao,
Paul Grannis,
Christophe Grojean,
Andrew Hutton
, et al. (37 additional authors not shown)
Abstract:
A large, world-wide community of physicists is working to realise an exceptional physics program of energy-frontier, electron-positron collisions with the International Linear Collider (ILC). This program will begin with a central focus on high-precision and model-independent measurements of the Higgs boson couplings. This method of searching for new physics beyond the Standard Model is orthogonal…
▽ More
A large, world-wide community of physicists is working to realise an exceptional physics program of energy-frontier, electron-positron collisions with the International Linear Collider (ILC). This program will begin with a central focus on high-precision and model-independent measurements of the Higgs boson couplings. This method of searching for new physics beyond the Standard Model is orthogonal to and complements the LHC physics program. The ILC at 250 GeV will also search for direct new physics in exotic Higgs decays and in pair-production of weakly interacting particles. Polarised electron and positron beams add unique opportunities to the physics reach. The ILC can be upgraded to higher energy, enabling precision studies of the top quark and measurement of the top Yukawa coupling and the Higgs self-coupling. The key accelerator technology, superconducting radio-frequency cavities, has matured. Optimised collider and detector designs, and associated physics analyses, were presented in the ILC Technical Design Report, signed by 2400 scientists. There is a strong interest in Japan to host this international effort. A detailed review of the many aspects of the project is nearing a conclusion in Japan. Now the Japanese government is preparing for a decision on the next phase of international negotiations, that could lead to a project start within a few years. The potential timeline of the ILC project includes an initial phase of about 4 years to obtain international agreements, complete engineering design and prepare construction, and form the requisite international collaboration, followed by a construction phase of 9 years.
△ Less
Submitted 28 January, 2019;
originally announced January 2019.
-
The International Linear Collider. A European Perspective
Authors:
Philip Bambade,
Ties Behnke,
Mikael Berggren,
Ivanka Bozovic-Jelisavcic,
Philip Burrows,
Massimo Caccia,
Paul Colas,
Gerald Eigen,
Lyn Evans,
Angeles Faus-Golfe,
Brian Foster,
Juan Fuster,
Frank Gaede,
Christophe Grojean,
Marek Idzik,
Andrea Jeremie,
Tadeusz Lesiak,
Aharon Levy,
Benno List,
Jenny List,
Joachim Mnich,
Olivier Napoly,
Carlo Pagani,
Roman Poeschl,
Francois Richard
, et al. (9 additional authors not shown)
Abstract:
The International Linear Collider (ILC) being proposed in Japan is an electron-positron linear collider with an initial energy of 250 GeV. The ILC accelerator is based on the technology of superconducting radio-frequency cavities. This technology has reached a mature stage in the European XFEL project and is now widely used. The ILC will start by measuring the Higgs properties, providing high-prec…
▽ More
The International Linear Collider (ILC) being proposed in Japan is an electron-positron linear collider with an initial energy of 250 GeV. The ILC accelerator is based on the technology of superconducting radio-frequency cavities. This technology has reached a mature stage in the European XFEL project and is now widely used. The ILC will start by measuring the Higgs properties, providing high-precision and model-independent determinations of its parameters. The ILC at 250 GeV will also search for direct new physics in exotic Higgs decays and in pair-production of weakly interacting particles. The use of polarised electron and positron beams opens new capabilities and scenarios that add to the physics reach. The ILC can be upgraded to higher energy, enabling precision studies of the top quark and measurement of the top Yukawa coupling and the Higgs self-coupling. The international -- including European -- interest for the project is very strong. Europe has participated in the ILC project since its early conception and plays a major role in its present development covering most of its scientific and technological aspects: physics studies, accelerator and detectors. The potential for a wide participation of European groups and laboratories is thus high, including important opportunities for European industry. Following decades of technical development, R&D, and design optimisation, the project is ready for construction and the European particle physics community, technological centers and industry are prepared to participate in this challenging endeavour.
△ Less
Submitted 28 January, 2019;
originally announced January 2019.
-
T2K ND280 Upgrade -- Technical Design Report
Authors:
K. Abe,
H. Aihara,
A. Ajmi,
C. Andreopoulos,
M. Antonova,
S. Aoki,
Y. Asada,
Y. Ashida,
A. Atherton,
E. Atkin,
D. Attié,
S. Ban,
M. Barbi,
G. J. Barker,
G. Barr,
M. Batkiewicz,
A. Beloshapkin,
V. Berardi,
L. Berns,
S. Bhadra,
J. Bian,
S. Bienstock,
A. Blondel,
J. Boix,
S. Bolognesi
, et al. (359 additional authors not shown)
Abstract:
In this document, we present the Technical Design Report of the Upgrade of the T2K Near Detector ND280. The goal of this upgrade is to improve the Near Detector performance to measure the neutrino interaction rate and to constrain the neutrino interaction cross-sections so that the uncertainty in the number of predicted events at Super-Kamiokande is reduced to about 4%. This will allow to improve…
▽ More
In this document, we present the Technical Design Report of the Upgrade of the T2K Near Detector ND280. The goal of this upgrade is to improve the Near Detector performance to measure the neutrino interaction rate and to constrain the neutrino interaction cross-sections so that the uncertainty in the number of predicted events at Super-Kamiokande is reduced to about 4%. This will allow to improve the physics reach of the T2K-II project. This goal is achieved by modifying the upstream part of the detector, adding a new highly granular scintillator detector (Super-FGD), two new TPCs (High-Angle TPC) and six TOF planes. Details about the detector concepts, design and construction methods are presented, as well as a first look at the test-beam data taken in Summer 2018. An update of the physics studies is also presented.
△ Less
Submitted 14 October, 2020; v1 submitted 11 January, 2019;
originally announced January 2019.
-
Measurement and simulation of two-phase CO$_2$ cooling for the AFTER electronics of the Micromegas modules for a Large Prototype of a Time Projection Chamber
Authors:
Deb Sankar Bhattacharya,
David Attie,
Paul Colas,
Supratik Mukhopadhyay,
Nayana Majumdar,
Sudeb Bhattacharya,
Sandip Sarkar,
Aparajita Bhattacharya,
Serguei Ganjour
Abstract:
The readout electronics of a Micromegas (MM) module consume nearly 26 W of electric power, which causes the temperature of electronic board to increase upto $70\,^{\circ}{\rm C}$. Increase in temperature results in damage of electronics. Development of temperature gradient in the Time Projection Chamber (TPC) may affect precise measurement as well. Two-phase CO$_2$ cooling has been applied to remo…
▽ More
The readout electronics of a Micromegas (MM) module consume nearly 26 W of electric power, which causes the temperature of electronic board to increase upto $70\,^{\circ}{\rm C}$. Increase in temperature results in damage of electronics. Development of temperature gradient in the Time Projection Chamber (TPC) may affect precise measurement as well. Two-phase CO$_2$ cooling has been applied to remove heat from the MM modules during two test beam experiments at DESY, Hamburg. Following the experimental procedure, a comprehensive study of the cooling technique has been accomplished for a single MM module by means of numerical simulation. This paper is focused to discuss the application of two-phase CO$_2$ cooling to keep the temperature below $30\,^{\circ}{\rm C}$ and stabilized within $0.2\,^{\circ}{\rm C}$.
△ Less
Submitted 31 December, 2017;
originally announced January 2018.
-
Experimental and numerical simulation of a TPC like set up for the measurement of ion backflow
Authors:
Deb Sankar Bhattacharya,
Purba Bhattacharya,
Prasant Kumar Rout,
Supratik Mukhopadhyay,
Sudeb Bhattacharya,
Nayana Majumdar,
Sandip Sarkar,
Paul Colas,
David Attie,
Serguei Ganjour,
Aparajita Bhattacharya
Abstract:
Ion backflow is one of the effects limiting the operation of a gaseous detector at high flux, by giving rise to space charge which perturbs the electric field. The natural ability of bulk Micromegas to suppress ion feedback is very effective and can help the TPC drift volume to remain relatively free of space charge build-up. An efficient and precise measurement of the backflow fraction is necessa…
▽ More
Ion backflow is one of the effects limiting the operation of a gaseous detector at high flux, by giving rise to space charge which perturbs the electric field. The natural ability of bulk Micromegas to suppress ion feedback is very effective and can help the TPC drift volume to remain relatively free of space charge build-up. An efficient and precise measurement of the backflow fraction is necessary to cope up with the track distortion due to the space charge effect. In a subtle but significant modification of the usual approach, we have made use of two drift meshes in order to measure the ion backflow fraction for bulk Micromegas detector. This helps to truly represent the backflow fraction for a TPC. Moreover, attempt is taken to optimize the field configuration between the drift meshes. In conjunction with the experimental measurement, Garfield simulation framework has been used to simulate the related physics processes numerically.
△ Less
Submitted 2 October, 2017;
originally announced October 2017.
-
Performance measurement of HARPO: a Time Projection Chamber as a gamma-ray telescope and polarimeter
Authors:
P. Gros,
S. Amano,
D. Attié,
P. Baron,
D. Baudin,
D. Bernard,
P. Bruel,
D. Calvet,
P. Colas,
S. Daté,
A. Delbart,
M. Frotin,
Y. Geerebaert,
B. Giebels,
D. Götz,
S. Hashimoto,
D. Horan,
T. Kotaka,
M. Louzir,
F. Magniette,
Y. Minamiyama,
S. Miyamoto,
H. Ohkuma,
P. Poilleux,
I. Semeniouk
, et al. (5 additional authors not shown)
Abstract:
We analyse the performance of a gas time projection chamber (TPC) as a high-performance gamma-ray telescope and polarimeter in the e$^+$e$^-$ pair creation regime. We use data collected at a gamma-ray beam of known polarisation. The TPC provides two orthogonal projections $(x,z)$ and $(y,z)$ of the tracks induced by each conversion in the gas volume. We use a simple vertex finder in which vertices…
▽ More
We analyse the performance of a gas time projection chamber (TPC) as a high-performance gamma-ray telescope and polarimeter in the e$^+$e$^-$ pair creation regime. We use data collected at a gamma-ray beam of known polarisation. The TPC provides two orthogonal projections $(x,z)$ and $(y,z)$ of the tracks induced by each conversion in the gas volume. We use a simple vertex finder in which vertices and pseudo-tracks exiting from them are identified.
We study the various contributions to the single-photon angular resolution using Monte Carlo simulations and compare them with the experimental data and find that they are in excellent agreement. The distribution of the azimutal angle of pair conversions shows a bias due to the non-cylindrical-symmetric structure of the detector. This bias would average out for a long duration exposure on a space mission, but for this pencil-beam characterisation we have ensured its accurate simulation by a double systematics control scheme, data taking with the detector rotated at several angles with respect to the beam polarisation direction and systematics control with a non-polarised beam.
We measure, for the first time, the polarisation asymmetry of a linearly polarised gamma-ray beam in the low energy pair creation regime. This sub-GeV energy range is critical for cosmic sources as their spectra are power laws which fall quickly as a function of increasing energy.
This work could pave the way to extending polarised gamma-ray astronomy beyond the MeV energy regime.
△ Less
Submitted 30 August, 2017; v1 submitted 20 June, 2017;
originally announced June 2017.
-
Readout technologies for directional WIMP Dark Matter detection
Authors:
J. B. R. Battat,
I. G. Irastorza,
A. Aleksandrov,
M. Ali Guler,
T. Asada,
E. Baracchini,
J. Billard,
G. Bosson,
O. Bourrion,
J. Bouvier,
A. Buonaura,
K. Burdge,
S. Cebrian,
P. Colas,
L. Consiglio,
T. Dafni,
N. D'Ambrosio,
C. Deaconu,
G. De Lellis,
T. Descombes,
A. Di Crescenzo,
N. Di Marco,
G. Druitt,
R. Eggleston,
E. Ferrer-Ribas
, et al. (68 additional authors not shown)
Abstract:
The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial…
▽ More
The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial resolution over large volumes, which puts strong requirements on the readout technologies. In this paper we review the various detector readout technologies used by directional detectors. In particular, we summarize the challenges, advantages and drawbacks of each approach, and discuss future prospects for these technologies.
△ Less
Submitted 6 October, 2016;
originally announced October 2016.
-
Directional detection of Dark Matter with the MIcro-tpc MAtrix of Chambers
Authors:
C. Couturier,
O. Guillaudin,
F. Naraghi,
Q. Riffard,
D. Santos,
N. Sauzet,
P. Colas,
E. Ferrer Ribas,
I. Giomataris,
J. Busto,
D. Fouchez,
C. Tao,
N. Zhou
Abstract:
Particles weakly interacting with ordinary matter, with an associated mass of the order of an atomic nucleus (WIMPs), are plausible candidates for Dark Matter. The direct detection of an elastic collision of a target nuclei induced by one of these WIMPs has to be discriminated from the signal produced by the neutrons, which leaves the same signal in a detector. The MIMAC (MIcro-tpc MAtrix of Chamb…
▽ More
Particles weakly interacting with ordinary matter, with an associated mass of the order of an atomic nucleus (WIMPs), are plausible candidates for Dark Matter. The direct detection of an elastic collision of a target nuclei induced by one of these WIMPs has to be discriminated from the signal produced by the neutrons, which leaves the same signal in a detector. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed an original prototype detector which combines a large pixelated Micromegas coupled with a fast, self-triggering, electronics. Aspects of the two-chamber module in operation in the Modane Underground Laboratory are presented: calibration, characterization of the $^{222}$Rn progeny. A new test bench combining a MIMAC chamber with the COMIMAC portable quenching line has been set up to characterize the 3D tracks of low energy ions in the MIMAC gas mixture: the preliminary results thereof are presented. Future steps are briefly discussed.
△ Less
Submitted 29 July, 2016;
originally announced July 2016.
-
First measurement of polarisation asymmetry of a gamma-ray beam between 1.74 to 74 MeV with the HARPO TPC
Authors:
Philippe Gros,
Sho Amano,
David Attié,
Denis Bernard,
Philippe Bruel,
Denis Calvet,
Paul Colas,
Schin Daté,
Alain Delbart,
Mickael Frotin,
Yannick Geerebaert,
Berrie Giebels,
Diego Götz,
S. Hashimoto,
Deirdr Horan,
T. Kotaka,
Marc Louzir,
Y. Minamiyama,
Shuji Miyamoto,
H. Ohkuma,
Patrick Poilleux,
Igor Semeniouk,
Patrick Sizun,
A. Takemoto,
M. Yamaguchi
, et al. (1 additional authors not shown)
Abstract:
Current $γ$-ray telescopes suffer from a gap in sensitivity in the energy range between 100keV and 100MeV, and no polarisation measurement has ever been done on cosmic sources above 1MeV. Past and present e$^+$e$^-$ pair telescopes are limited at lower energies by the multiple scattering of electrons in passive tungsten converter plates. This results in low angular resolution, and, consequently, a…
▽ More
Current $γ$-ray telescopes suffer from a gap in sensitivity in the energy range between 100keV and 100MeV, and no polarisation measurement has ever been done on cosmic sources above 1MeV. Past and present e$^+$e$^-$ pair telescopes are limited at lower energies by the multiple scattering of electrons in passive tungsten converter plates. This results in low angular resolution, and, consequently, a drop in sensitivity to point sources below 1GeV. The polarisation information, which is carried by the azimuthal angle of the conversion plane, is lost for the same reasons.
HARPO (Hermetic ARgon POlarimeter) is an R\&D program to characterise the operation of a gaseous detector (a Time Projection Chamber or TPC) as a high angular-resolution and sensitivity telescope and polarimeter for $γ$ rays from cosmic sources. It represents a first step towards a future space instrument in the MeV-GeV range.
We built and characterised a 30cm cubic demonstrator [SPIE 91441M], and put it in a polarised $γ$-ray beam at the NewSUBARU accelerator in Japan. Data were taken at photon energies from 1.74MeV to 74MeV, and with different polarisation configurations.
We describe the experimental setup in beam. We then describe the software we developed to reconstruct the photon conversion events, with special focus on low energies. We also describe the thorough simulation of the detector used to compare results. Finally we will present the performance of the detector as extracted from this analysis and preliminary measurements of the polarisation asymmetry.
This beam-test qualification of a gas TPC prototype in a $γ$-ray beam could open the way to high-performance $γ$-ray astronomy and polarimetry in the MeV-GeV energy range in the near future.
△ Less
Submitted 30 June, 2016;
originally announced June 2016.
-
Performance Studies of Bulk Micromegas of Different Design Parameters
Authors:
Purba Bhattacharya,
Sudeb Bhattacharya,
Nayana Majumdar,
Supratik Mukhopadhyay,
Sandip Sarkar,
Paul Colas,
David Attie
Abstract:
The present work involves the comparison of various bulk Micromegas detectors having different design parameters. Six detectors with amplification gaps of $64,~128,~192,~220 ~μ\mathrm{m}$ and mesh hole pitch of $63,~78 ~μ\mathrm{m}$ were tested at room temperature and normal gas pressure. Two setups were built to evaluate the effect of the variation of the amplification gap and mesh hole pitch on…
▽ More
The present work involves the comparison of various bulk Micromegas detectors having different design parameters. Six detectors with amplification gaps of $64,~128,~192,~220 ~μ\mathrm{m}$ and mesh hole pitch of $63,~78 ~μ\mathrm{m}$ were tested at room temperature and normal gas pressure. Two setups were built to evaluate the effect of the variation of the amplification gap and mesh hole pitch on different detector characteristics. The gain, energy resolution and electron transmission of these Micromegas detectors were measured in Argon-Isobutane (90:10) gas mixture while the measurements of the ion backflow were carried out in P10 gas. These measured characteristics have been compared in detail to the numerical simulations using the Garfield framework that combines packages such as neBEM, Magboltz and Heed.
△ Less
Submitted 10 May, 2016;
originally announced May 2016.
-
Investigation of Ion Backflow in Bulk Micromegas Detectors
Authors:
Purba Bhattacharya,
Deb Sankar Bhattacharya,
Supratik Mukhopadhyay,
Sudeb Bhattacharya,
Nayana Majumdar,
Sandip Sarkar,
Paul Colas,
David Attie
Abstract:
The operation of gas detectors is often limited by secondary effects, originating from avalanche-induced photons and ions. Ion backflow is one of the effects limiting the operation of a gas detector at high flux, by giving rise to space charge which disturbs the electric field locally. For the Micromegas detector, a large fraction of the secondary positive ions created in the avalanche can be stop…
▽ More
The operation of gas detectors is often limited by secondary effects, originating from avalanche-induced photons and ions. Ion backflow is one of the effects limiting the operation of a gas detector at high flux, by giving rise to space charge which disturbs the electric field locally. For the Micromegas detector, a large fraction of the secondary positive ions created in the avalanche can be stopped at the micro-mesh. The present work involves measurements of the ion backflow fraction (using an experimental setup comprising of two drift planes) in bulk Micromegas detectors as a function of detector design parameters. These measured characteristics have also been compared in detail to numerical simulations using the Garfield framework that combines packages such as neBEM, Magboltz and Heed. Further, the effect of using a second micro-mesh on ion backflow and other parameters has been studied numerically.
△ Less
Submitted 10 May, 2016;
originally announced May 2016.
-
A Time Projection Chamber with GEM-Based Readout
Authors:
The LCTPC Collaboration,
David Attié,
Ties Behnke,
Alain Bellerive,
Oleg Bezshyyko,
Deb Sankar Bhattacharya,
Purba Bhattacharya,
Sudeb Bhattacharya,
Stefano Caiazza,
Paul Colas,
Gilles De Lentdecker,
Klaus Dehmelt,
Klaus Desch,
Ralf Diener,
Madhu Dixit,
Ivor Fleck,
Keisuke Fujii,
Takahiro Fusayasu,
Serguei Ganjour,
Yuanning Gao,
Philippe Gros,
Peter Hayman,
Vincent Hedberg,
Katsumasa Ikematsu,
Leif Jönsson
, et al. (45 additional authors not shown)
Abstract:
For the International Large Detector concept at the planned International Linear Collider, the use of time projection chambers (TPC) with micro-pattern gas detector readout as the main tracking detector is investigated. In this paper, results from a prototype TPC, placed in a 1 T solenoidal field and read out with three independent GEM-based readout modules, are reported. The TPC was exposed to a…
▽ More
For the International Large Detector concept at the planned International Linear Collider, the use of time projection chambers (TPC) with micro-pattern gas detector readout as the main tracking detector is investigated. In this paper, results from a prototype TPC, placed in a 1 T solenoidal field and read out with three independent GEM-based readout modules, are reported. The TPC was exposed to a 6 GeV electron beam at the DESY II synchrotron. The efficiency for reconstructing hits, the measurement of the drift velocity, the space point resolution and the control of field inhomogeneities are presented.
△ Less
Submitted 4 April, 2016;
originally announced April 2016.
-
Measurement of 1.7 to 74 MeV polarised gamma rays with the HARPO TPC
Authors:
Y. Geerebaert,
Ph. Gros,
S. Amano,
D. Attié,
D. Bernard,
P. Bruel,
D. Calvet,
P. Colas,
S. Daté,
A. Delbart,
M. Frotin,
B. Giebels,
D. Götz,
S. Hashimoto,
D. Horan,
T. Kotaka,
M. Louzir,
Y. Minamiyama,
S. Miyamoto,
H. Ohkuma,
P. Poilleux,
I. Semeniouk,
P. Sizun,
A. Takemoto,
M. Yamaguchi
, et al. (1 additional authors not shown)
Abstract:
Current γ-ray telescopes based on photon conversions to electron-positron pairs, such as Fermi, use tungsten converters. They suffer of limited angular resolution at low energies, and their sensitivity drops below 1 GeV. The low multiple scattering in a gaseous detector gives access to higher angular resolution in the MeV-GeV range, and to the linear polarisation of the photons through the azimuth…
▽ More
Current γ-ray telescopes based on photon conversions to electron-positron pairs, such as Fermi, use tungsten converters. They suffer of limited angular resolution at low energies, and their sensitivity drops below 1 GeV. The low multiple scattering in a gaseous detector gives access to higher angular resolution in the MeV-GeV range, and to the linear polarisation of the photons through the azimuthal angle of the electron-positron pair.
HARPO is an R&D program to characterise the operation of a TPC (Time Projection Chamber) as a high angular-resolution and sensitivity telescope and polarimeter for γ rays from cosmic sources. It represents a first step towards a future space instrument. A 30 cm cubic TPC demonstrator was built, and filled with 2 bar argon-based gas. It was put in a polarised γ-ray beam at the NewSUBARU accelerator in Japan in November 2014. Data were taken at different photon energies from 1.7 MeV to 74 MeV, and with different polarisation configurations. The electronics setup is described, with an emphasis on the trigger system. The event reconstruction algorithm is quickly described, and preliminary measurements of the polarisation of 11 MeVphotons are shown.
△ Less
Submitted 22 March, 2016;
originally announced March 2016.
-
MIMAC low energy electron-recoil discrimination measured with fast neutrons
Authors:
Q. Riffard,
D. Santos,
O. Guillaudin,
G. Bosson,
O. Bourrion,
J. Bouvier,
T. Descombes,
J. -F. Muraz,
L. Lebreton,
D. Maire,
P. Colas,
I. Giomataris,
J. Busto,
D. Fouchez,
J. Brunner,
C. Tao
Abstract:
MIMAC (MIcro-TPC MAtrix of Chambers) is a directional WIMP Dark Matter detector project. Direct dark matter experiments need a high level of electron/recoil discrimination to search for nuclear recoils produced by WIMP-nucleus elastic scattering. In this paper, we proposed an original method for electron event rejection based on a multivariate analysis applied to experimental data acquired using m…
▽ More
MIMAC (MIcro-TPC MAtrix of Chambers) is a directional WIMP Dark Matter detector project. Direct dark matter experiments need a high level of electron/recoil discrimination to search for nuclear recoils produced by WIMP-nucleus elastic scattering. In this paper, we proposed an original method for electron event rejection based on a multivariate analysis applied to experimental data acquired using monochromatic neutron fields. This analysis shows that a $10^5$ rejection power is reachable for electron/recoil discrimination. Moreover, the efficiency was estimated by a Monte-Carlo simulation showing that a 105 electron rejection power is reached with a $86.49\pm 0.17$\% nuclear recoil efficiency considering the full energy range and $94.67\pm0.19$\% considering a 5~keV lower threshold.
△ Less
Submitted 4 July, 2016; v1 submitted 4 February, 2016;
originally announced February 2016.
-
LEETECH facility as a flexible source of low energy electrons
Authors:
D. Attie,
S. Barsuk,
O. Bezshyyko,
L. Burmistrov,
A. Chaus,
P. Colas,
O. Fedorchuk,
L. Golinka-Bezshyyko,
I. Kadenko,
V. Krylov,
V. Kubytskyi,
R. Lopez,
H. Monard,
V. Rodin,
M. Titov,
D. Tomassini,
A. Variola
Abstract:
A new versatile facility LEETECH for detector R&D, tests and calibration is designed and constructed. It uses electrons produced by the photoinjector PHIL at LAL, Orsay and provides a powerful tool for wide range R&D studies of different detector concepts delivering "mono-chromatic" samples of low energy electrons with adjustable energy and intensity. Among other innovative instrumentation techniq…
▽ More
A new versatile facility LEETECH for detector R&D, tests and calibration is designed and constructed. It uses electrons produced by the photoinjector PHIL at LAL, Orsay and provides a powerful tool for wide range R&D studies of different detector concepts delivering "mono-chromatic" samples of low energy electrons with adjustable energy and intensity. Among other innovative instrumentation techniques, LEETECH will be used for testing various gaseous tracking detectors and studying new Micromegas/InGrid concept which has very promising characteristics of spatial resolution and can be a good candidate for particle tracking and identification. In this paper the importance and expected characteristics of such facility based on detailed simulation studies are addressed.
△ Less
Submitted 17 January, 2016;
originally announced January 2016.
-
First detection of tracks of radon progeny recoils by MIMAC
Authors:
Q. Riffard,
D. Santos,
G. Bosson,
O. Bourrion,
T. Descombes,
C. Fourel,
O. Guillaudin,
J. -F. Muraz,
P. Colas,
E. Ferrer-Ribas,
I. Giomataris,
J. Busto,
D. Fouchez,
C. Tao,
L. Lebreton,
D. Maire
Abstract:
The MIMAC experiment is a $μ$-TPC matrix project for directional dark matter search. Directional detection is a strategy based on the measurement of the WIMP flux anisotropy due to the solar system motion with respect to the dark matter halo. The main purpose of MIMAC project is the measurement of the energy and the direction of nuclear recoils in 3D produced by elastic scattering of WIMPs. Since…
▽ More
The MIMAC experiment is a $μ$-TPC matrix project for directional dark matter search. Directional detection is a strategy based on the measurement of the WIMP flux anisotropy due to the solar system motion with respect to the dark matter halo. The main purpose of MIMAC project is the measurement of the energy and the direction of nuclear recoils in 3D produced by elastic scattering of WIMPs. Since June 2012 a bi-chamber prototype is operating at the Modane underground laboratory. In this paper, we report the first ionization energy and 3D track observations of nuclear recoils produced by the radon progeny. This measurement shows the capability of the MIMAC detector and opens the possibility to explore the low energy recoil directionality signature.
△ Less
Submitted 20 June, 2017; v1 submitted 22 April, 2015;
originally announced April 2015.
-
HARPO: beam characterization of a TPC for gamma-ray polarimetry and high angular-resolution astronomy in the MeV-GeV range
Authors:
Shaobo Wang,
Denis Bernard,
Philippe Bruel,
Mickael Frotin,
Yannick Geerebaert,
Berrie Giebels,
Philippe Gros,
Deirdre Horan,
Marc Louzir,
Patrick Poilleux,
Igor Semeniouk,
David Attié,
Denis Calvet,
Paul Colas,
Alain Delbart,
Patrick Sizun,
Diego Götz,
Sho Amano,
Takuya Kotaka,
Satoshi Hashimoto,
Yasuhito Minamiyama,
Akinori Takemoto,
Masashi Yamaguchi,
Shuji Miyamoto,
Schin Daté
, et al. (1 additional authors not shown)
Abstract:
A time projection chamber (TPC) can be used to measure the polarization of gamma rays with excellent angular precision and sensitivity in the MeV-GeV energy range through the conversion of photons to e+e- pairs. The Hermetic ARgon POlarimeter (HARPO) prototype was built to demonstrate this concept. It was recently tested in the polarized photon beam at the NewSUBARU facility in Japan. We present t…
▽ More
A time projection chamber (TPC) can be used to measure the polarization of gamma rays with excellent angular precision and sensitivity in the MeV-GeV energy range through the conversion of photons to e+e- pairs. The Hermetic ARgon POlarimeter (HARPO) prototype was built to demonstrate this concept. It was recently tested in the polarized photon beam at the NewSUBARU facility in Japan. We present this data-taking run, which demonstrated the excellent performance of the HARPO TPC.
△ Less
Submitted 12 March, 2015;
originally announced March 2015.
-
HARPO: a TPC as a gamma-ray telescope and polarimeter
Authors:
Denis Bernard,
Philippe Bruel,
Mickael Frotin,
Yannick Geerebaert,
Berrie Giebels,
Philippe Gros,
Deirdre Horan,
Marc Louzir,
Patrick Poilleux,
Igor Semeniouk,
Shaobo Wang,
Shebli Anvar,
David Attié,
Paul Colas,
Alain Delbart,
Patrick Sizun,
Diego Götz
Abstract:
A gas Time Projection Chamber can be used for gamma-ray astronomy with excellent angular-precision and sensitivity to faint sources, and for polarimetry, through the measurement of photon conversion to $e^+e^-$ pairs. We present the expected performance in simulations and the recent development of a demonstrator for tests in a polarized photon beam.
A gas Time Projection Chamber can be used for gamma-ray astronomy with excellent angular-precision and sensitivity to faint sources, and for polarimetry, through the measurement of photon conversion to $e^+e^-$ pairs. We present the expected performance in simulations and the recent development of a demonstrator for tests in a polarized photon beam.
△ Less
Submitted 28 July, 2014; v1 submitted 18 June, 2014;
originally announced June 2014.
-
Comparison of Bulk Micromegas with Different Amplification Gaps
Authors:
Purba Bhattacharya,
Sudeb Bhattacharya,
Nayana Majumdar,
Supratik Mukhopadhyay,
Sandip Sarkar,
Paul Colas,
David Attie
Abstract:
The bulk Micromegas detector is considered to be a promising candidate for building TPCs for several future experiments including the projected linear collider. The standard bulk with a spacing of 128 micron has already established itself as a good choice for its performances in terms of gas gain uniformity, energy and space point resolution, and its capability to efficiently pave large readout su…
▽ More
The bulk Micromegas detector is considered to be a promising candidate for building TPCs for several future experiments including the projected linear collider. The standard bulk with a spacing of 128 micron has already established itself as a good choice for its performances in terms of gas gain uniformity, energy and space point resolution, and its capability to efficiently pave large readout surfaces with minimum dead zone. The present work involves the comparison of this standard bulk with a relatively less used bulk Micromegas detector having a larger amplification gap of 192 micron. Detector gain, energy resolution and electron transparency of these Micromegas have been measured under different conditions in various argon based gas mixtures to evaluate their performance. These measured characteristics have also been compared in detail to numerical simulations using the Garfield framework that combines packages such as neBEM, Magboltz and Heed. Further, we have carried out another numerical study to determine the effect of dielectric spacers on different detector features. A comprehensive comparison of the two detectors has been presented and analyzed in this work.
△ Less
Submitted 23 April, 2013;
originally announced April 2013.
-
Characterization and simulation of resistive-MPGDs with resistive strip and layer topologies
Authors:
J. Galan,
D. Attie,
A. Chaus,
P. Colas,
A. Delbart,
E. Ferrer-Ribas,
I. Giomataris,
F. J. Iguaz,
A. Gongadze,
T. Papaevangelou,
A. Peyaud
Abstract:
The use of resistive technologies to MPGD detectors is taking advantage for many new applications, including high rate and energetic particle flux scenarios. The recent use of these technologies in large area detectors makes necessary to understand and characterize the response of this type of detectors in order to optimize or constrain the parameters used in its production, material resistivity,…
▽ More
The use of resistive technologies to MPGD detectors is taking advantage for many new applications, including high rate and energetic particle flux scenarios. The recent use of these technologies in large area detectors makes necessary to understand and characterize the response of this type of detectors in order to optimize or constrain the parameters used in its production, material resistivity, strip width, or layer thickness. The values to be chosen will depend on the environmental conditions in which the detector will be placed, and the requirements in time resolution and gain, improving the detector performance for each given application. We present two different methods to calculate the propagation of charge diffusion through different resistive topologies; one is based on a FEM of solving the telegraph equation in our particular strip detector scheme, the other is based on a semi-analytical approach of charge diffusion and is used to determine the charge evolution in a resistive layer.
△ Less
Submitted 7 April, 2013;
originally announced April 2013.
-
A Piggyback resistive Micromegas
Authors:
D. Attie,
A. Chaus,
P. Colas,
E. Ferrer,
J. Galan,
I. Giomatari,
F. J. Iguaz,
A. Gongadze,
R. De Oliveira,
T. Papaevangelou,
A. Peyaud
Abstract:
A novel read-out architecture has been developed for the Micromegas detector. The anode element is made of a resistive layer on a ceramic substrate. The detector part is entirely separated from the read-out element. Without significant loss, signals are transmitted by capacitive coupling to the read-out pads. The detector provides high gas gain, good energy resolution and the resistive layer assur…
▽ More
A novel read-out architecture has been developed for the Micromegas detector. The anode element is made of a resistive layer on a ceramic substrate. The detector part is entirely separated from the read-out element. Without significant loss, signals are transmitted by capacitive coupling to the read-out pads. The detector provides high gas gain, good energy resolution and the resistive layer assures spark protection to the electronics. This assembly could be combined with modern pixel array electronic ASICs. This readout organization is free on how the pixels are designed, arranged and connected. We present first results taken with a MediPix read-out chip.
△ Less
Submitted 5 February, 2013; v1 submitted 31 August, 2012;
originally announced August 2012.
-
Infrastructure for Detector Research and Development towards the International Linear Collider
Authors:
J. Aguilar,
P. Ambalathankandy,
T. Fiutowski,
M. Idzik,
Sz. Kulis,
D. Przyborowski,
K. Swientek,
A. Bamberger,
M. Köhli,
M. Lupberger,
U. Renz,
M. Schumacher,
Andreas Zwerger,
A. Calderone,
D. G. Cussans,
H. F. Heath,
S. Mandry,
R. F. Page,
J. J. Velthuis,
D. Attié,
D. Calvet,
P. Colas,
X. Coppolani,
Y. Degerli,
E. Delagnes
, et al. (252 additional authors not shown)
Abstract:
The EUDET-project was launched to create an infrastructure for developing and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infras…
▽ More
The EUDET-project was launched to create an infrastructure for developing and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infrastructures for tracking detectors as well as for calorimetry.
△ Less
Submitted 23 January, 2012;
originally announced January 2012.
-
Micromegas detector developments for MIMAC
Authors:
E. Ferrer-Ribas,
D. Attié,
D. Calvet,
P. Colas,
F. Druillole,
Y. Giomataris,
F. J. Iguaz,
J. P. Mols,
J. Pancin,
T. Papaevangelou,
J. Billard,
G. Bosson,
J. L. Bouly,
O. Bourrion,
Ch. Fourel,
C. Grignon,
O. Guillaudin,
F. Mayet,
J. P. Richer,
D. Santos,
C. Golabek,
L. Lebreton
Abstract:
The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC. The recent Micromegas efforts towards building a large size detector will be described, in particular the characterization measurements of a prototype detector of 10 $\times$ 10 cm$^2$ with a 2 dimensional readout plane. Track reconstruction with alpha particles will be shown.
The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC. The recent Micromegas efforts towards building a large size detector will be described, in particular the characterization measurements of a prototype detector of 10 $\times$ 10 cm$^2$ with a 2 dimensional readout plane. Track reconstruction with alpha particles will be shown.
△ Less
Submitted 12 September, 2011; v1 submitted 8 September, 2011;
originally announced September 2011.
-
The T2K Experiment
Authors:
T2K Collaboration,
K. Abe,
N. Abgrall,
H. Aihara,
Y. Ajima,
J. B. Albert,
D. Allan,
P. -A. Amaudruz,
C. Andreopoulos,
B. Andrieu,
M. D. Anerella,
C. Angelsen,
S. Aoki,
O. Araoka,
J. Argyriades,
A. Ariga,
T. Ariga,
S. Assylbekov,
J. P. A. M. de André,
D. Autiero,
A. Badertscher,
O. Ballester,
M. Barbi,
G. J. Barker,
P. Baron
, et al. (499 additional authors not shown)
Abstract:
The T2K experiment is a long-baseline neutrino oscillation experiment. Its main goal is to measure the last unknown lepton sector mixing angle θ_{13} by observing ν_e appearance in a ν_μ beam. It also aims to make a precision measurement of the known oscillation parameters, Δm^{2}_{23} and sin^{2} 2θ_{23}, via ν_μ disappearance studies. Other goals of the experiment include various neutrino cross…
▽ More
The T2K experiment is a long-baseline neutrino oscillation experiment. Its main goal is to measure the last unknown lepton sector mixing angle θ_{13} by observing ν_e appearance in a ν_μ beam. It also aims to make a precision measurement of the known oscillation parameters, Δm^{2}_{23} and sin^{2} 2θ_{23}, via ν_μ disappearance studies. Other goals of the experiment include various neutrino cross section measurements and sterile neutrino searches. The experiment uses an intense proton beam generated by the J-PARC accelerator in Tokai, Japan, and is composed of a neutrino beamline, a near detector complex (ND280), and a far detector (Super-Kamiokande) located 295 km away from J-PARC. This paper provides a comprehensive review of the instrumentation aspect of the T2K experiment and a summary of the vital information for each subsystem.
△ Less
Submitted 8 June, 2011; v1 submitted 6 June, 2011;
originally announced June 2011.
-
Micromegas detector developments for Dark Matter directional detection with MIMAC
Authors:
F. J. Iguaz,
D. Attié,
D. Calvet,
P. Colas,
F. Druillole,
E. Ferrer-Ribas,
I. Giomataris,
J. P. Mols,
J. Pancin,
T. Papaevangelou,
J. Billard,
G. Bosson,
J. L. Bouly,
O. Bourrion,
Ch. Fourel,
C. Grignon,
O. Guillaudin,
F. Mayet,
J. P. Richer,
D. Santos,
C. Golabek,
L. Lebreton
Abstract:
The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC using a high precision Micromegas readout plane. We will describe in detail the recent developments done with bulk Micromegas detectors as well as the characterisation measurements performed in an Argon(95%)-Isobutane(5%) mixture. Track measurements with alpha particles will be shown.
The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC using a high precision Micromegas readout plane. We will describe in detail the recent developments done with bulk Micromegas detectors as well as the characterisation measurements performed in an Argon(95%)-Isobutane(5%) mixture. Track measurements with alpha particles will be shown.
△ Less
Submitted 10 May, 2011;
originally announced May 2011.
-
Ultra low energy results and their impact to dark matter and low energy neutrino physics
Authors:
E. Bougamont,
P. Colas,
J. Derre,
I. Giomataris,
G. Gerbier,
M. Gros,
P. Magnier,
X. F. Navick,
P. Salin,
I. Savvidis,
G. Tsiledakis,
J. D. Vergados
Abstract:
We present ultra low energy results taken with the novel Spherical Proportional Counter. The energy threshold has been pushed down to about 25 eV and single electrons are clearly collected and detected. To reach such performance low energy calibration systems have been successfully developed: - A pulsed UV lamp extracting photoelectrons from the inner surface of the detector - Various radioactiv…
▽ More
We present ultra low energy results taken with the novel Spherical Proportional Counter. The energy threshold has been pushed down to about 25 eV and single electrons are clearly collected and detected. To reach such performance low energy calibration systems have been successfully developed: - A pulsed UV lamp extracting photoelectrons from the inner surface of the detector - Various radioactive sources allowing low energy peaks through fluorescence processes. The bench mark result is the observation of a well resolved peak at 270 eV due to carbon fluorescence which is unique performance for such large-massive detector. It opens a new window in dark matter and low energy neutrino search and may allow detection of neutrinos from a nuclear reactor or from supernova via neutrino-nucleus elastic scattering
△ Less
Submitted 20 October, 2010;
originally announced October 2010.
-
Search for neutral Higgs bosons decaying into four taus at LEP2
Authors:
ALEPH Collaboration,
S. Schael,
R. Barate,
R. Brunelière,
I. De Bonis,
D. Decamp,
C. Goy,
S. Jézéquel,
J. -P. Lees,
F. Martin,
E. Merle,
M. -N. Minard,
B. Pietrzyk,
B. Trocmé S. Bravo,
M. P. Casado,
M. Chmeissani,
J. M. Crespo,
E. Fernandez,
M. Fernandez-Bosman,
Ll. Garrido,
M. Martinez,
A. Pacheco,
H. Ruiz,
A. Colaleo,
D. Creanza
, et al. (236 additional authors not shown)
Abstract:
A search for the production and non-standard decay of a Higgs boson, h, into four taus through intermediate pseudoscalars, a, is conducted on 683 pb-1 of data collected by the ALEPH experiment at centre-of-mass energies from 183 to 209 GeV. No excess of events above background is observed, and exclusion limits are placed on the combined production cross section times branching ratio, ξ^2 = σ(e+e…
▽ More
A search for the production and non-standard decay of a Higgs boson, h, into four taus through intermediate pseudoscalars, a, is conducted on 683 pb-1 of data collected by the ALEPH experiment at centre-of-mass energies from 183 to 209 GeV. No excess of events above background is observed, and exclusion limits are placed on the combined production cross section times branching ratio, ξ^2 = σ(e+e- --> Zh)/σ_{SM}(e+e- --> Zh) x B(h --> aa)x B(a --> τ^+τ^-)^2. For mh < 107 GeV/c2 and 4 < ma < 10 GeV/c2, ξ^2 > 1 is excluded at the 95% confidence level.
△ Less
Submitted 19 April, 2010; v1 submitted 2 March, 2010;
originally announced March 2010.
-
Directional detection of galactic Dark Matter
Authors:
F. Mayet,
J. Billard,
G. Bernard,
G. Bosson,
O. Bourrion,
C. Grignon,
O. Guillaudin,
C. Koumeir,
J. P. Richer,
D. Santos,
P. Colas,
E. Ferer,
I. Giomataris,
A. Allaoua,
L. Lebreton
Abstract:
Directional detection of galactic Dark Matter is a promising search strategy for discriminating geniune WIMP events from background ones. We present technical progress on gaseous detectors as well as recent phenomenological studies, allowing the design and construction of competitive experiments.
Directional detection of galactic Dark Matter is a promising search strategy for discriminating geniune WIMP events from background ones. We present technical progress on gaseous detectors as well as recent phenomenological studies, allowing the design and construction of competitive experiments.
△ Less
Submitted 18 January, 2010;
originally announced January 2010.
-
The case for a directional dark matter detector and the status of current experimental efforts
Authors:
S. Ahlen,
N. Afshordi,
J. B. R. Battat,
J. Billard,
N. Bozorgnia,
S. Burgos,
T. Caldwell,
J. M. Carmona,
S. Cebrian,
P. Colas,
T. Dafni,
E. Daw,
D. Dujmic,
A. Dushkin,
W. Fedus,
E. Ferrer,
D. Finkbeiner,
P. H. Fisher,
J. Forbes,
T. Fusayasu,
J. Galan,
T. Gamble,
C. Ghag,
I. Giomataris,
M. Gold
, et al. (87 additional authors not shown)
Abstract:
We present the case for a dark matter detector with directional sensitivity. This document was developed at the 2009 CYGNUS workshop on directional dark matter detection, and contains contributions from theorists and experimental groups in the field. We describe the need for a dark matter detector with directional sensitivity; each directional dark matter experiment presents their project's stat…
▽ More
We present the case for a dark matter detector with directional sensitivity. This document was developed at the 2009 CYGNUS workshop on directional dark matter detection, and contains contributions from theorists and experimental groups in the field. We describe the need for a dark matter detector with directional sensitivity; each directional dark matter experiment presents their project's status; and we close with a feasibility study for scaling up to a one ton directional detector, which would cost around $150M.
△ Less
Submitted 1 November, 2009;
originally announced November 2009.
-
MICROMEGAS chambers for hadronic calorimetry at a future linear collider
Authors:
C. Adloff,
D. Attie,
J. Blaha,
S. Cap,
M. Chefdeville,
P. Colas,
A. Dalmaz,
C. Drancourt,
A. Espargiliere,
R. Gaglione,
R. Gallet,
N. Geffroy,
I. Giomataris,
J. Jaquemier,
Y. Karyotakis,
F. Peltier,
J. Prast,
G. Vouters
Abstract:
Prototypes of MICROMEGAS chambers, using bulk technology and analog readout, with 1x1cm2 readout segmentation have been built and tested. Measurements in Ar/iC4H10 (95/5) and Ar/CO2 (80/20) are reported. The dependency of the prototypes gas gain versus pressure, gas temperature and amplification gap thickness variations has been measured with an 55Fe source and a method for temperature and press…
▽ More
Prototypes of MICROMEGAS chambers, using bulk technology and analog readout, with 1x1cm2 readout segmentation have been built and tested. Measurements in Ar/iC4H10 (95/5) and Ar/CO2 (80/20) are reported. The dependency of the prototypes gas gain versus pressure, gas temperature and amplification gap thickness variations has been measured with an 55Fe source and a method for temperature and pressure correction of data is presented. A stack of four chambers has been tested in 200GeV/c and 7GeV/c muon and pion beams respectively. Measurements of response uniformity, detection efficiency and hit multiplicity are reported. A bulk MICROMEGAS prototype with embedded digital readout electronics has been assembled and tested. The chamber layout and first results are presented.
△ Less
Submitted 21 September, 2009; v1 submitted 17 September, 2009;
originally announced September 2009.
-
A prototype of a directional detector for non-baryonic dark matter search: MIMAC (Micro-TPC Matrix of Chambers)
Authors:
C. Grignon,
G. Bernard,
J. Billard,
G. Bosson,
O. Bourrion,
O. Guillaudin,
C. Koumeir,
F. Mayet,
D. Santos,
P. Colas,
E. Ferrer,
I. Giomataris,
A. Allaoua,
L. Lebreton
Abstract:
We have developed a micro-tpc using a pixelized bulk micromegas coupled to dedicated acquisition electronics as a read-out allowing to reconstruct the three dimensional track of a few keV recoils. The prototype has been tested with the Amande facility at the IRSN-Cadarache providing monochromatic neutrons. The first results concerning discrimination of a few keV electrons and proton recoils are…
▽ More
We have developed a micro-tpc using a pixelized bulk micromegas coupled to dedicated acquisition electronics as a read-out allowing to reconstruct the three dimensional track of a few keV recoils. The prototype has been tested with the Amande facility at the IRSN-Cadarache providing monochromatic neutrons. The first results concerning discrimination of a few keV electrons and proton recoils are presented.
△ Less
Submitted 30 October, 2009; v1 submitted 3 September, 2009;
originally announced September 2009.
-
Dark matter directional detection with MIMAC
Authors:
C. Grignon,
J. Billard,
G. Bosson,
O. Bourrion,
O. Guillaudin,
C. Koumeir,
F. Mayet,
D. Santos,
P. Colas,
E. Ferrer,
I. Giomataris
Abstract:
MiMac is a project of micro-TPC matrix of gaseous (He3, CF4) chambers for direct detection of non-baryonic dark matter. Measurement of both track and ionization energy will allow the electron-recoil discrimination, while access to the directionnality of the tracks will open a unique way to distinguish a geniune WIMP signal from any background. First reconstructed tracks of 5.9 keV electrons are…
▽ More
MiMac is a project of micro-TPC matrix of gaseous (He3, CF4) chambers for direct detection of non-baryonic dark matter. Measurement of both track and ionization energy will allow the electron-recoil discrimination, while access to the directionnality of the tracks will open a unique way to distinguish a geniune WIMP signal from any background. First reconstructed tracks of 5.9 keV electrons are presented as a proof of concept.
△ Less
Submitted 29 May, 2009;
originally announced May 2009.
-
Micromegas micro-TPC for direct Dark Matter search with MIMAC
Authors:
F. Mayet,
O. Guillaudin,
C. Grignon,
C. Koumeir,
D. Santos,
P. Colas,
I. Giomataris
Abstract:
The MIMAC project is a multi-chamber detector for Dark Matter search, aiming at measuring both track and ionization with a matrix of micromegas micro-TPC filled with He3 and CF4. Recent experimental results on the first measurements of the Helium quenching factor at low energy (1 keV recoil) are presented, together with the first simulation of the track reconstruction. Recontruction of track of…
▽ More
The MIMAC project is a multi-chamber detector for Dark Matter search, aiming at measuring both track and ionization with a matrix of micromegas micro-TPC filled with He3 and CF4. Recent experimental results on the first measurements of the Helium quenching factor at low energy (1 keV recoil) are presented, together with the first simulation of the track reconstruction. Recontruction of track of alpha from Radon impurities is shown as a first proof of concept.
△ Less
Submitted 28 May, 2009;
originally announced May 2009.
-
Low energy measurements with Helium Micromegas micro-TPC
Authors:
O. Guillaudin,
F. Mayet,
C. Grignon,
C. Koumeir,
D. Santos,
P. Colas,
I. Giomataris
Abstract:
The measurement of the ionization produced by particles in a medium presents a great interest in several fields from metrology to particule physics and cosmology. The ionization quenching factor is defined as the fraction of energy released by ionisation by a recoil in a medium compared with its kinetic energy. At low energy, in the range of a few keV, the ionization falls rapidly and systematic…
▽ More
The measurement of the ionization produced by particles in a medium presents a great interest in several fields from metrology to particule physics and cosmology. The ionization quenching factor is defined as the fraction of energy released by ionisation by a recoil in a medium compared with its kinetic energy. At low energy, in the range of a few keV, the ionization falls rapidly and systematic measurement are needed. We have developped an experimental setup devoted to the measurement of low energy (keV) ionization quenching factor for the MIMAC project. The ionization produced in the gas has been measured with a Micromegas detector filled with Helium gas mixture.
△ Less
Submitted 10 April, 2009;
originally announced April 2009.
-
Ionization Quenching Factor Measurement of Helium 4
Authors:
D. Santos,
F. Mayet,
O. Guillaudin,
Th. Lamy,
S. Ranchon,
A. Trichet,
P. Colas,
I. Giomataris
Abstract:
The ionization quenching factor (IQF) is defined as the fraction of energy released by a recoil in a medium through ionization compared with its total kinetic energy. At low energies, in the range of a few keV, the ionization produced in a medium falls rapidly and systematic measurements are needed. We report measurements carried out at such low energies as a function of the pressure in He4 at 3…
▽ More
The ionization quenching factor (IQF) is defined as the fraction of energy released by a recoil in a medium through ionization compared with its total kinetic energy. At low energies, in the range of a few keV, the ionization produced in a medium falls rapidly and systematic measurements are needed. We report measurements carried out at such low energies as a function of the pressure in He4 at 350, 700, 1000 and 1300 mbar. In order to produce a nucleus moving with a controlled energy in the detection volume, we have developed an Electron Cyclotron Resonance Ion Source (ECRIS) coupled to an ionization chamber by a differential pumping. The quenching factor of He4 has been measured for the first time down to 1 keV recoil energies. An important deviation with respect to the phenomenological calculations has been found allowing an estimation of the scintillation produced in He4 as a function of pressure. The variation of the IQF as a function of the percentage of isobutane, used as quencher, is also presented.
△ Less
Submitted 7 October, 2008;
originally announced October 2008.
-
A novel large-volume Spherical Detector with Proportional Amplification read-out
Authors:
I. Giomataris,
I. Irastorza,
I. Savvidis,
S. Andriamonje,
S. Aune,
M. Chapelier,
Ph. Charvin,
P. Colas,
J. Derre,
E. Ferrer,
M. Gros,
X. F. Navick,
P. Salin,
J. D. Vergados
Abstract:
A new type of radiation detector based on a spherical geometry is presented. The detector consists of a large spherical gas volume with a central electrode forming a radial electric field. Charges deposited in the conversion volume drift to the central sensor where they are amplified and collected. We introduce a small spherical sensor located at the center acting as a proportional amplification…
▽ More
A new type of radiation detector based on a spherical geometry is presented. The detector consists of a large spherical gas volume with a central electrode forming a radial electric field. Charges deposited in the conversion volume drift to the central sensor where they are amplified and collected. We introduce a small spherical sensor located at the center acting as a proportional amplification structure. It allows high gas gains to be reached and operates in a wide range of gas pressures. Signal development and the absolute amplitude of the response are consistent with predictions. Sub-keV energy threshold with good energy resolution is achieved. This new concept has been proven to operate in a simple and robust way and allows reading large volumes with a single read-out channel. The detector performance presently achieved is already close to fulfill the demands of many challenging projects from low energy neutrino physics to dark matter detection with applications in neutron, alpha and gamma spectroscopy.
△ Less
Submitted 17 July, 2008;
originally announced July 2008.
-
Micromegas TPC studies at high magnetic fields using the charge dispersion signal
Authors:
M. Dixit,
D. Attie,
A. Bellerive,
K. Boudjemline,
P. Colas,
P. Giganon,
I. Giomataris,
V. Lepeltier,
S. Liu,
J. -P. Martin,
K. Sachs,
Y. Shin,
S. Turnbull
Abstract:
The International Linear Collider (ILC) Time Projection Chamber (TPC) transverse space-point resolution goal is 100 microns for all tracks including stiff 90 degree tracks with the full 2 meter drift. A Micro Pattern Gas Detector (MPGD) readout TPC can achieve the target resolution with existing techniques using 1 mm or narrower pads at the expense of increased detector cost and complexity. The ne…
▽ More
The International Linear Collider (ILC) Time Projection Chamber (TPC) transverse space-point resolution goal is 100 microns for all tracks including stiff 90 degree tracks with the full 2 meter drift. A Micro Pattern Gas Detector (MPGD) readout TPC can achieve the target resolution with existing techniques using 1 mm or narrower pads at the expense of increased detector cost and complexity. The new MPGD readout technique of charge dispersion can achieve good resolution without resorting to narrow pads. This has been demonstrated previously for 2 mm x 6 mm pads with GEMs and Micromegas in cosmic ray tests and in a KEK beam test in a 1 Tesla magnet. We have recently tested a Micromegas-TPC using the charge dispersion readout concept in a high field super-conducting magnet at DESY. The measured Micromegas gain was found to be constant within 0.5% for magnetic fields up to 5 Tesla. With the strong suppression of transverse diffusion at high magnetic fields, we measure a flat 50 micron resolution at 5 Tesla over the full 15 cm drift length of our prototype TPC.
△ Less
Submitted 28 March, 2007;
originally announced March 2007.
-
Progress on a spherical TPC for low energy neutrino detection
Authors:
S Aune,
P Colas,
H Deschamps,
J Dolbeau,
G Fanourakis,
E Ferrer Ribas,
T Enqvist,
T Geralis,
Y Giomataris,
P Gorodetzky,
G J Gounaris,
M Gros,
I G Irastorza,
K Kousouris,
V Lepeltier,
J Morales,
T Patzak,
E A Paschos,
P Salin,
I Savvidis,
J. D. Vergados
Abstract:
The new concept of the spherical TPC aims at relatively large target masses with low threshold and background, keeping an extremely simple and robust operation. Such a device would open the way to detect the neutrino-nucleus interaction, which, although a standard process, remains undetected due to the low energy of the neutrino-induced nuclear recoils. The progress in the development of the fis…
▽ More
The new concept of the spherical TPC aims at relatively large target masses with low threshold and background, keeping an extremely simple and robust operation. Such a device would open the way to detect the neutrino-nucleus interaction, which, although a standard process, remains undetected due to the low energy of the neutrino-induced nuclear recoils. The progress in the development of the fist 1 m$^3$ prototype at Saclay is presented. Other physics goals of such a device could include supernova detection, low energy neutrino oscillations and study of non-standard properties of the neutrino, among others.
△ Less
Submitted 26 November, 2005;
originally announced November 2005.
-
Spatial Resolution of a Micromegas-TPC Using the Charge Dispersion Signal
Authors:
A. Bellerive,
K. Boudjemline,
R. Carnegie,
M. Dixit,
J. Miyamoto,
E. Neuheimer,
A. Rankin,
E. Rollin,
K. Sachs,
J. -P. Martin,
V. Lepeltier,
P. Colas,
A. Giganon,
I. Giomataris
Abstract:
The Time Projection Chamber (TPC) for the International Linear Collider will need to measure about 200 track points with a resolution close to 100 $μ$m. A Micro Pattern Gas Detector (MPGD) readout TPC could achieve the desired resolution with existing techniques using sub-millimeter width pads at the expense of a large increase in the detector cost and complexity. We have recently applied a new…
▽ More
The Time Projection Chamber (TPC) for the International Linear Collider will need to measure about 200 track points with a resolution close to 100 $μ$m. A Micro Pattern Gas Detector (MPGD) readout TPC could achieve the desired resolution with existing techniques using sub-millimeter width pads at the expense of a large increase in the detector cost and complexity. We have recently applied a new MPGD readout concept of charge dispersion to a prototype GEM-TPC and demonstrated the feasibility of achieving good resolution with pads similar in width to the ones used for the proportional wire TPC. The charge dispersion studies were repeated with a Micromegas TPC amplification stage. We present here our first results on the Micromegas-TPC resolution with charge dispersion. The TPC resolution with the Micromegas readout is compared to our earlier GEM results and to the resolution expected from electron statistics and transverse diffusion in a gaseous TPC.
△ Less
Submitted 11 October, 2005;
originally announced October 2005.
-
NOSTOS: a spherical TPC to detect low energy neutrinos
Authors:
S. Aune,
P. Colas,
J. Dolbeau,
G. Fanourakis,
E. Ferrer-Ribas,
T. Geralis,
Y. Giomataris,
P. Gorodetzky,
G. J. Gounaris,
I. G. Irastorza,
K. Kousouris,
V. Lepeltier,
T. Patzak,
E. A. Paschos,
P. Salin,
I. Savvidis,
J. D. Vergados
Abstract:
A novel low-energy ($\sim$few keV) neutrino-oscillation experiment NOSTOS, combining a strong tritium source and a high pressure spherical Time Projection Chamber (TPC) detector 10 m in radius has been recently proposed. The oscillation of neutrinos of such energies occurs within the size of the detector itself, potentially allowing for a very precise (and rather systematics-free) measure of the…
▽ More
A novel low-energy ($\sim$few keV) neutrino-oscillation experiment NOSTOS, combining a strong tritium source and a high pressure spherical Time Projection Chamber (TPC) detector 10 m in radius has been recently proposed. The oscillation of neutrinos of such energies occurs within the size of the detector itself, potentially allowing for a very precise (and rather systematics-free) measure of the oscillation parameters, in particular, of the smaller mixing angle $θ_{13}$, which value could be determined for the first time. This detector could also be sensitive to the neutrino magnetic moment and be capable of accurately measure the Weinberg angle at low energy. The same apparatus, filled with high pressure Xenon, exhibits a high sensitivity as a Super Nova neutrino detector with extra galactic sensitivity. The outstanding benefits of the new concept of the spherical TPC will be presented, as well as the issues to be demonstrated in the near future by an ongoing R&D. The very first results of small prototype in operation in Saclay are shown.
△ Less
Submitted 21 March, 2005; v1 submitted 18 March, 2005;
originally announced March 2005.
-
NOSTOS experiment and new trends in rare event detection
Authors:
I. Giomataris,
S. Aune,
P. Colas,
I. Irastorza,
B. Peyaud,
J. Dolbeau,
P. Gorodetzky,
H. van der Graff,
T. Patzak,
P. Salin,
V. Lepeltier,
J. D. Vergados
Abstract:
A novel low-energy neutrino-oscillation experiment NOSTOS, combining a strong tritium source and a high pressure spherical TPC detector (10 m in radius) has been recently proposed. The goal of the experiment is to measure the mixing angle $θ_{13}$, the neutrino magnetic moment and the Weinberg angle at low energy. The same apparatus, filled with high pressure Xenon, exhibits a high sensitivity a…
▽ More
A novel low-energy neutrino-oscillation experiment NOSTOS, combining a strong tritium source and a high pressure spherical TPC detector (10 m in radius) has been recently proposed. The goal of the experiment is to measure the mixing angle $θ_{13}$, the neutrino magnetic moment and the Weinberg angle at low energy. The same apparatus, filled with high pressure Xenon, exhibits a high sensitivity as a Super Nova neutrino detector with extra galactic sensitivity. Results of a first prototype will be shown and a short-term experimental program will be discussed.
△ Less
Submitted 17 February, 2005;
originally announced February 2005.
-
Micromegas in a Bulk
Authors:
I. Giomataris,
R. De Oliveira,
S. Andriamonje,
S. Aune,
G. Charpak,
P. Colas,
A. Giganon,
Ph. Rebourgeard,
P. Salin
Abstract:
In this paper we present a novel way to manufacture the bulk Micromegas detector. A simple process based on the PCB (Printed Circuit Board) technology is employed to produce the entire sensitive detector. Such fabrication process could be extended to very large area detectors made by the industry. The low cost fabrication together with the robustness of the electrode materials will make it extre…
▽ More
In this paper we present a novel way to manufacture the bulk Micromegas detector. A simple process based on the PCB (Printed Circuit Board) technology is employed to produce the entire sensitive detector. Such fabrication process could be extended to very large area detectors made by the industry. The low cost fabrication together with the robustness of the electrode materials will make it extremely attractive for several applications ranging from particle physics and astrophysics to medicine
△ Less
Submitted 2 January, 2005;
originally announced January 2005.