Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content

Showing 1–12 of 12 results for author: Andriamonje, S

.
  1. arXiv:1605.00791  [pdf

    physics.ins-det nucl-ex

    Development of the MICROMEGAS Detector for Measuring the Energy Spectrum of Alpha Particles by using a 241-Am Source

    Authors: Do Yoon Kim, Cheolmin Ham, Jae Won Shin, Tae-Sun Park, Seung-Woo Hong, Samuel Andriamonje, Yacine Kadi, Claudio Tenreiro

    Abstract: We have developed MICROMEGAS (MICRO MEsh GASeous) detectors for detecting α particles emitted from an 241-Am standard source. The voltage applied to the ionization region of the detector is optimized for stable operation at room temperature and atmospheric pressure. The energy of α particles from the 241-Am source can be varied by changing the flight path of the α particle from the 241 Am source.… ▽ More

    Submitted 3 May, 2016; originally announced May 2016.

    Journal ref: Journal of the Korean Physical Society, vol 68, No. 9, 2016, P. 1060~1068

  2. Measurement and analysis of the Am-243 neutron capture cross section at the n_TOF facility at CERN

    Authors: n_TOF Collaboration, :, E. Mendoza, D. Cano-Ott, C. Guerrero, E. Berthoumieux, U. Abbondanno, G. Aerts, F. Alvarez-Velarde, S. Andriamonje, J. Andrzejewski, P. Assimakopoulos, L. Audouin, G. Badurek, J. Balibrea, P. Baumann, F. Becvar, F. Belloni, F. Calvino, M. Calviani, R. Capote, C. Carrapico, A. Carrillo de Albornoz, P. Cennini, V. Chepel , et al. (108 additional authors not shown)

    Abstract: Background:The design of new nuclear reactors and transmutation devices requires to reduce the present neutron cross section uncertainties of minor actinides. Purpose: Reduce the $^{243}$Am(n,$γ$) cross section uncertainty. Method: The $^{243}$Am(n,$γ$) cross section has been measured at the n_TOF facility at CERN with a BaF$_{2}$ Total Absorption Calorimeter, in the energy range between 0.7 eV an… ▽ More

    Submitted 4 December, 2014; originally announced December 2014.

    Journal ref: Phys. Rev. C 90, 034608 (2014)

  3. $^{62}$Ni($n,γ$) and $^{63}$Ni($n,γ$) cross sections measured at n_TOF/CERN

    Authors: C. Lederer, C. Massimi, E. Berthoumieux, N. Colonna, R. Dressler, C. Guerrero, F. Gunsing, F. Käppeler, N. Kivel, M. Pignatari, R. Reifarth, D. Schumann, A. Wallner, S. Altstadt, S. Andriamonje, J. Andrzejewski, L. Audouin, M. Barbagallo, V. Becares, F. Becvar, F. Belloni, B. Berthier, J. Billowes, V. Boccone, D. Bosnar , et al. (90 additional authors not shown)

    Abstract: The cross section of the $^{62}$Ni($n,γ$) reaction was measured with the time-of-flight technique at the neutron time-of-flight facility n_TOF at CERN. Capture kernels of 42 resonances were analyzed up to 200~keV neutron energy and Maxwellian averaged cross sections (MACS) from $kT=5-100$ keV were calculated. With a total uncertainty of 4.5%, the stellar cross section is in excellent agreement wit… ▽ More

    Submitted 19 March, 2014; originally announced March 2014.

    Journal ref: Physical Review C 89, 025810 (2014)

  4. arXiv:1110.2641  [pdf, other

    physics.ins-det

    New developments in Micromegas Microbulk detectors

    Authors: F. J. Iguaz, S. Andriamonje, F. Belloni, E. Berthoumieux, M. Calviani, T. Dafni, R. De Oliveira, E. Ferrer-Ribas, J. Galán, J. A. García, I. Giomataris, C. Guerrero, F. Gunsing, D. C. Herrera, I. G. Irastorza, T. Papaevangelou, A. Rodríguez, A. Tomás

    Abstract: A new Micromegas manufacturing technique, based on kapton etching technology, has been recently developed, improving the uniformity and stability of this kind of readouts. Excellent energy resolutions have been obtained, reaching 11% FWHM for the 5.9 keV photon peak of 55Fe source and 1.8% FWHM for the 5.5 MeV alpha peak of the 241Am source. The new detector has other advantages like its flexible… ▽ More

    Submitted 12 October, 2011; originally announced October 2011.

    Comments: To be published in the Proceedings of the TIPP2011 conference (Physics Procedia)

  5. Search for 14.4 keV solar axions emitted in the M1-transition of 57Fe nuclei with CAST

    Authors: CAST Collaboration, S. Andriamonje, S. Aune, D. Autiero, K. Barth, A. Belov, B. Beltrán, H. Bräuninger, J. M. Carmona, S. Cebrián, J. I. Collar, T. Dafni, M. Davenport, L. Di Lella, C. Eleftheriadis, J. Englhauser, G. Fanourakis, E. Ferrer-Ribas, H. Fischer, J. Franz, P. Friedrich, T. Geralis, I. Giomataris, S. Gninenko, H. Gómez , et al. (36 additional authors not shown)

    Abstract: We have searched for 14.4 keV solar axions or more general axion-like particles (ALPs), that may be emitted in the M1 nuclear transition of 57Fe, by using the axion-to-photon conversion in the CERN Axion Solar Telescope (CAST) with evacuated magnet bores (Phase I). From the absence of excess of the monoenergetic X-rays when the magnet was pointing to the Sun, we set model-independent constraints… ▽ More

    Submitted 4 December, 2009; v1 submitted 24 June, 2009; originally announced June 2009.

    Comments: 23 pages, 5 figures. Revised version of the paper after referee`s comments. Main changes in the Measurement and data analysis section

    Journal ref: JCAP 0912:002,2009

  6. Search for solar axion emission from 7Li and D(p,gamma)3He nuclear decays with the CAST gamma-ray calorimeter

    Authors: CAST Collaboration, S. Andriamonje, S. Aune, D. Autiero, K. Barth, A. Belov, B. Beltran, H. Brauninger, J. M. Carmona, S. Cebrian, J. I. Collar, T. Dafni, M. Davenport, L. Di. Lella, C. Eleftheriadis, J. Englhauser, G. Fanourakis, E. Ferrer. Ribas, H. Fischer, J. Franz, P. Friedrich, T. Geralis, I. Giomataris, S. Gninenko, H. Gomez , et al. (36 additional authors not shown)

    Abstract: We present the results of a search for a high-energy axion emission signal from 7Li (0.478 MeV) and D(p,gamma)3He (5.5 MeV) nuclear transitions using a low-background gamma-ray calorimeter during Phase I of the CAST experiment. These so-called "hadronic axions" could provide a solution to the long-standing strong-CP problem and can be emitted from the solar core from nuclear M1 transitions. This… ▽ More

    Submitted 6 March, 2010; v1 submitted 14 April, 2009; originally announced April 2009.

    Comments: 20 pages, 8 figures, final version to be published in JCAP

    Journal ref: JCAP 1003:032,2010

  7. A novel large-volume Spherical Detector with Proportional Amplification read-out

    Authors: I. Giomataris, I. Irastorza, I. Savvidis, S. Andriamonje, S. Aune, M. Chapelier, Ph. Charvin, P. Colas, J. Derre, E. Ferrer, M. Gros, X. F. Navick, P. Salin, J. D. Vergados

    Abstract: A new type of radiation detector based on a spherical geometry is presented. The detector consists of a large spherical gas volume with a central electrode forming a radial electric field. Charges deposited in the conversion volume drift to the central sensor where they are amplified and collected. We introduce a small spherical sensor located at the center acting as a proportional amplification… ▽ More

    Submitted 17 July, 2008; originally announced July 2008.

    Comments: 13 pages, 13 figures

    Journal ref: JINST 3:P09007,2008

  8. The Micromegas detector of the CAST experiment

    Authors: P. Abbon, S. Andriamonje, S. Aune, T. Dafni, M. Davenport, E. Delagnes, R. de Oliveira, G. Fanourakis, E. Ferrer Ribas, J. Franz, T. Geralis, M. Gros, Y. Giomataris, I. G. Irastorza, K. Kousouris, J. Morales, T. Papaevangelou, J. Ruz, K. Zachariadou, K. Zioutas

    Abstract: A low background Micromegas detector has been operating in the CAST experiment at CERN for the search of solar axions during the first phase of the experiment (2002-2004). The detector, made out of low radioactivity materials, operated efficiently and achieved a very low level of background rejection (5 x 10^-5 counts/keV/cm^2/s) without shielding.

    Submitted 22 February, 2007; originally announced February 2007.

    Comments: 13 pages, 12 figures and images, submitted to New Journal of

    Journal ref: NewJ.Phys.9:170,2007

  9. Neutron imaging with a Micromegas detector

    Authors: F. Jeanneau, R. Junca, J. Pancin, M. Voytchev, S. Andriamonje, V. Dangendorf, I. Espagnon, H. Friedrich, A. Giganon, I. Giomataris, A. Menelle, A. Pluquet, L. R. Rodriguez

    Abstract: The micropattern gaseous detector Micromegas has been developed for several years in Saclay and presents good performance for neutron detection. A prototype for neutron imaging has been designed and new results obtained in thermal neutron beams are presented. Based on previous results demonstrating a good 1D spatial resolution, a tomographic image of a multiwire cable has been performed using a… ▽ More

    Submitted 21 July, 2006; originally announced July 2006.

    Comments: 6 pages, 10 figures, presented at IEEE 2004 conference in Roma, Italy

    Journal ref: IEEE-TNS, vol. 53, No 2, april 2006, p 595-600

  10. New neutron detector based on Micromegas technology for ADS projects

    Authors: Samuel Andriamonje, Gregory Andriamonje, Stephan Aune, Gilles Ban, Stephane Breaud, Christophe Blandin, Esther Ferrer, Benoit Geslot, Arnaud Giganon, Ioannis Giomataris, Christian Jammes, Yacine Kadi, Philippe Laborie, Jean Francois Lecolley, Julien Pancin, Marc Riallot, Roberto Rosa, Lucia Sarchiapone, Jean Claude Steckmeyer, Joel Tillier

    Abstract: A new neutron detector based on Micromegas technology has been developed for the measurement of the simulated neutron spectrum in the ADS project. After the presentation of simulated neutron spectra obtained in the interaction of 140 MeV protons with the spallation target inside the TRIGA core, a full description of the new detector configuration is given. The advantage of this detector compared… ▽ More

    Submitted 7 July, 2006; originally announced July 2006.

    Comments: 5 pages, 7 figures, AccApp05 Conference

    Journal ref: Nucl.Instrum.Meth.A562:755-759,2006

  11. A low background Micromegas detector for the CAST experiment

    Authors: P. Abbon, S. Andriamonje, S. Aune, D. Besin, S. Cazaux, P. Contrepois, T. Dafni, T. Decker, N. Duportail, G. Fanourakis, E. Ferrer Ribas, T. Geralis, A. Giganon, I. Giomataris, M. Gros, R. Hill, I. G. Irastorza, K. Kousouris, J. Morales, M. Pivovaroff, M. Riallot, R. Soufli, K. Zachariadou, G. Zaffanela

    Abstract: A low background Micromegas detector has been operating on the CAST experiment at CERN for the search of solar axions during the first phase of the experiment (2002-2004). The detector operated efficiently and achieved a very low level of background rejection ($5\times 10^{-5}$ counts keV$^{-1}$cm$^{-2}$s$^{-1}$) thanks to its good spatial and energy resolution as well as the low radioactivity m… ▽ More

    Submitted 28 October, 2005; originally announced October 2005.

    Comments: 6 pages, 3 figures To appear on the proceedings of the 9th ICATPP Conference on AStroparticle, Particle, Space Physics, Detectors and Medical Physics Applications

  12. Micromegas in a Bulk

    Authors: I. Giomataris, R. De Oliveira, S. Andriamonje, S. Aune, G. Charpak, P. Colas, A. Giganon, Ph. Rebourgeard, P. Salin

    Abstract: In this paper we present a novel way to manufacture the bulk Micromegas detector. A simple process based on the PCB (Printed Circuit Board) technology is employed to produce the entire sensitive detector. Such fabrication process could be extended to very large area detectors made by the industry. The low cost fabrication together with the robustness of the electrode materials will make it extre… ▽ More

    Submitted 2 January, 2005; originally announced January 2005.

    Comments: 6 pages, 4 figures

    Report number: DAPNIA-04-80