Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content

Showing 1–39 of 39 results for author: Chepel, V

.
  1. arXiv:2312.14663  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    First observation of liquid xenon electroluminescence with a Microstrip Plate

    Authors: G. Martinez-Lema, V. Chepel, A. Roy, A. Breskin

    Abstract: We report on the first observation of electroluminescence amplification with a Microstrip Plate immersed in liquid xenon. The electroluminescence of the liquid, induced by alpha-particles, was observed in an intense non-uniform electric field in the vicinity of 8-$μ$m narrow anode strips interlaced with wider cathode ones, deposited on the same side of a glass substrate. The electroluminescence yi… ▽ More

    Submitted 23 January, 2024; v1 submitted 22 December, 2023; originally announced December 2023.

    Comments: 17 pages, 14 figures, prepared for submission to JINST

  2. arXiv:2301.12990  [pdf, other

    physics.ins-det astro-ph.IM

    First results on FHM -- a Floating Hole Multiplier

    Authors: V. Chepel, G. Martinez-Lema, A. Roy, A. Breskin

    Abstract: A proof of principle of a novel concept for event recording in dual-phase liquid xenon detectors -- the Floating Hole Multiplier (FHM) -- is presented. It is shown that a standard Thick Gaseous Electron Multiplier (THGEM), freely floating on the liquid xenon surface permits extraction of electrons from the liquid to the gas. Secondary scintillation induced by the extracted electrons in the THGEM h… ▽ More

    Submitted 30 January, 2023; originally announced January 2023.

    Comments: 12 pages

  3. arXiv:2203.02309  [pdf, other

    physics.ins-det astro-ph.CO hep-ex nucl-ex

    A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics

    Authors: J. Aalbers, K. Abe, V. Aerne, F. Agostini, S. Ahmed Maouloud, D. S. Akerib, D. Yu. Akimov, J. Akshat, A. K. Al Musalhi, F. Alder, S. K. Alsum, L. Althueser, C. S. Amarasinghe, F. D. Amaro, A. Ames, T. J. Anderson, B. Andrieu, N. Angelides, E. Angelino, J. Angevaare, V. C. Antochi, D. Antón Martin, B. Antunovic, E. Aprile, H. M. Araújo , et al. (572 additional authors not shown)

    Abstract: The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut… ▽ More

    Submitted 4 March, 2022; originally announced March 2022.

    Comments: 77 pages, 40 figures, 1262 references

    Report number: INT-PUB-22-003

    Journal ref: J. Phys. G: Nucl. Part. Phys. 50 (2023) 013001

  4. arXiv:1610.02656  [pdf

    physics.med-ph physics.ins-det

    Iterative reconstruction of SiPM light response functions in a square-shaped compact gamma camera

    Authors: A. Morozov, F. Alves, J. Marcos, R. Martins, L. Pereira, V. Solovov, V. Chepel

    Abstract: Compact gamma cameras with a square-shaped monolithic scintillator crystal and an array of silicon photomultipliers (SiPMs) are actively being developed for applications in areas such as small animal imaging, cancer diagnostics and radiotracer guided surgery. Statistical methods of position reconstruction, which are potentially superior to the traditional centroid method, require accurate knowledg… ▽ More

    Submitted 9 October, 2016; originally announced October 2016.

  5. ANTS2 package: simulation and experimental data processing for Anger camera type detectors

    Authors: A. Morozov, V. Solovov, R. Martins, F. Neves, V. Domingos, V. Chepel

    Abstract: ANTS2 is a simulation and data processing package developed for position sensitive detectors with Anger camera type readout. The simulation module of ANTS2 is based on ROOT package from CERN, which is used to store the detector geometry and to perform 3D navigation. The module is capable of simulating particle sources, performing particle tracking, generating photons of primary and secondary scint… ▽ More

    Submitted 23 February, 2016; originally announced February 2016.

  6. arXiv:1602.01296  [pdf, other

    physics.ins-det physics.med-ph

    B-spline parameterization of spatial response in a monolithic scintillation camera

    Authors: V. Solovov, A. Morozov, V. Chepel, V. Domingos, R. Martins

    Abstract: A framework for parameterization of the light response functions (LRFs) in a scintillation camera is presented. It is based on approximation of the measured or simulated photosensor response with weighted sums of uniform cubic B-splines or their tensor products. The LRFs represented in this way are smooth, computationally inexpensive to evaluate and require much less computer memory than non-param… ▽ More

    Submitted 22 December, 2016; v1 submitted 3 February, 2016; originally announced February 2016.

    Comments: 16 pages, 9 figures, Published in JINST

    Journal ref: JINST 11 P09014 (2016)

  7. arXiv:1509.02354  [pdf

    physics.ins-det

    Direct observation of bubble-assisted electroluminescence in liquid xenon

    Authors: E. Erdal, L. Arazi, V. Chepel, M. L. Rappaport, D. Vartsky, A. Breskin

    Abstract: Bubble formation in liquid xenon underneath a Thick Gaseous Electron Multiplier (THGEM) electrode immersed in liquid xenon was observed with a CCD camera. With voltage across the THGEM, the appearance of bubbles was correlated with that of electroluminescence signals induced by ionization electrons from alpha-particle tracks. This confirms recent indirect evidence that the observed photons are due… ▽ More

    Submitted 8 September, 2015; originally announced September 2015.

    Comments: Submitted to JINST

  8. arXiv:1505.02316  [pdf

    physics.ins-det astro-ph.IM hep-ex

    Liquid Hole Multipliers: bubble-assisted electroluminescence in liquid xenon

    Authors: L. Arazi, E. Erdal, A. E. C. Coimbra, M. L. Rappaport, D. Vartsky, V. Chepel, A. Breskin

    Abstract: In this work we discuss the mechanism behind the large electroluminescence signals observed at relatively low electric fields in the holes of a Thick Gas Electron Multiplier (THGEM) electrode immersed in liquid xenon. We present strong evidence that the scintillation light is generated in xenon bubbles trapped below the THGEM holes. The process is shown to be remarkably stable over months of opera… ▽ More

    Submitted 13 May, 2015; v1 submitted 9 May, 2015; originally announced May 2015.

    Comments: Submitted to JINST

  9. arXiv:1501.07310  [pdf

    physics.med-ph physics.ins-det

    Iterative reconstruction of the detector response for medical gamma cameras

    Authors: A. Morozov, V. Solovov, F. Alves, V. Domingos, R. Martins, F. Neves, V. Chepel

    Abstract: Statistical event reconstruction techniques can give better results for gamma cameras than the traditional centroid method. However, implementation of such techniques requires detailed knowledge of the PMT light response functions. Here we describe an iterative technique which allows to obtain the response functions from flood irradiation data without imposing strict requirements on the spatial un… ▽ More

    Submitted 28 January, 2015; originally announced January 2015.

    Comments: 16 pages, 11 figures

  10. Measurement and analysis of the Am-243 neutron capture cross section at the n_TOF facility at CERN

    Authors: n_TOF Collaboration, :, E. Mendoza, D. Cano-Ott, C. Guerrero, E. Berthoumieux, U. Abbondanno, G. Aerts, F. Alvarez-Velarde, S. Andriamonje, J. Andrzejewski, P. Assimakopoulos, L. Audouin, G. Badurek, J. Balibrea, P. Baumann, F. Becvar, F. Belloni, F. Calvino, M. Calviani, R. Capote, C. Carrapico, A. Carrillo de Albornoz, P. Cennini, V. Chepel , et al. (108 additional authors not shown)

    Abstract: Background:The design of new nuclear reactors and transmutation devices requires to reduce the present neutron cross section uncertainties of minor actinides. Purpose: Reduce the $^{243}$Am(n,$γ$) cross section uncertainty. Method: The $^{243}$Am(n,$γ$) cross section has been measured at the n_TOF facility at CERN with a BaF$_{2}$ Total Absorption Calorimeter, in the energy range between 0.7 eV an… ▽ More

    Submitted 4 December, 2014; originally announced December 2014.

    Journal ref: Phys. Rev. C 90, 034608 (2014)

  11. Measurement and simulation of the muon-induced neutron yield in lead

    Authors: L. Reichhart, A. Lindote, D. Yu. Akimov, H. M. Araujo, E. J. Barnes, V. A. Belov, A. Bewick, A. A. Burenkov, V. Chepel, A. Currie, L. DeViveiros, B. Edwards, V. Francis, C. Ghag, A. Hollingsworth, M. Horn, G. E. Kalmus, A. S. Kobyakin, A. G. Kovalenko, V. A. Kudryavtsev, V. N. Lebedenko, M. I. Lopes, R. Luscher, P. Majewski, A. St J. Murphy , et al. (14 additional authors not shown)

    Abstract: A measurement is presented of the neutron production rate in lead by high energy cosmic-ray muons at a depth of 2850 m water equivalent (w.e.) and a mean muon energy of 260 GeV. The measurement exploits the delayed coincidences between muons and the radiative capture of induced neutrons in a highly segmented tonne scale plastic scintillator detector. Detailed Monte Carlo simulations reproduce well… ▽ More

    Submitted 4 November, 2013; v1 submitted 18 February, 2013; originally announced February 2013.

    Comments: 12 pages, 13 figures

    Journal ref: Astroparticle Physics 47 (2013) 67-76

  12. arXiv:1207.2292  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Liquid noble gas detectors for low energy particle physics

    Authors: Vitaly Chepel, Henrique Araújo

    Abstract: We review the current status of liquid noble gas radiation detectors with energy threshold in the keV range, wich are of interest for direct dark matter searches, measurement of coherent neutrino scattering and other low energy particle physics experiments. Emphasis is given to the operation principles and the most important instrumentation aspects of these detectors, principally of those operated… ▽ More

    Submitted 29 April, 2013; v1 submitted 10 July, 2012; originally announced July 2012.

    Journal ref: 2013 JINST 8 R04001

  13. arXiv:1112.1481  [pdf, ps, other

    physics.ins-det astro-ph.IM physics.med-ph

    Position Reconstruction in a Dual Phase Xenon Scintillation Detector

    Authors: V. N. Solovov, V. A. Belov, D. Yu. Akimov, H. M. Araújo, E. J. Barnes, A. A. Burenkov, V. Chepel, A. Currie, L. DeViveiros, B. Edwards, C. Ghag, A. Hollingsworth, M. Horn, G. E. Kalmus, A. S. Kobyakin, A. G. Kovalenko, V. N. Lebedenko, A. Lindote, M. I. Lopes, R. Lüscher, P. Majewski, A. St J. Murphy, F. Neves, S. M. Paling, J. Pinto da Cunha , et al. (11 additional authors not shown)

    Abstract: We studied the application of statistical reconstruction algorithms, namely maximum likelihood and least squares methods, to the problem of event reconstruction in a dual phase liquid xenon detector. An iterative method was developed for in-situ reconstruction of the PMT light response functions from calibration data taken with an uncollimated gamma-ray source. Using the techniques described, the… ▽ More

    Submitted 26 September, 2012; v1 submitted 7 December, 2011; originally announced December 2011.

    Comments: 8 pages, 7 figures, in the Conference Record of IEEE NSS 2011, accepted for publication in IEEE Trans. on Nuc. Sci

  14. arXiv:1112.0080  [pdf, ps, other

    physics.ins-det hep-ex

    Performance data from the ZEPLIN-III second science run

    Authors: P. Majewski, V. N. Solovov, D. Yu. Akimov, H. M. Araujo, E. J. Barnes, V. A. Belov, A. A. Burenkov, V. Chepel, A. Currie, L. DeViveiros, B. Edwards, C. Ghag, A. Hollingsworth, M. Horn, G. E. Kalmus, A. S. Kobyakin, A. G. Kovalenko, V. N. Lebedenko, A. Lindote, M. I. Lopes, R. Luscher, A. St J. Murphy, F. Neves, S. M. Paling, J. Pinto da Cunha , et al. (10 additional authors not shown)

    Abstract: ZEPLIN-III is a two-phase xenon direct dark matter experiment located at the Boulby Mine (UK). After its first science run in 2008 it was upgraded with: an array of low background photomultipliers, a new anti-coincidence detector system with plastic scintillator and an improved calibration system. After 319 days of data taking the second science run ended in May 2011. In this paper we describe the… ▽ More

    Submitted 30 November, 2011; originally announced December 2011.

    Comments: Submitted to PSD9 conference proceedings

  15. arXiv:1111.2248  [pdf, ps, other

    nucl-ex astro-ph.IM

    Quenching Factor for Low Energy Nuclear Recoils in a Plastic Scintillator

    Authors: L. Reichhart, D. Yu. Akimov, H. M. Araujo, E. J. Barnes, V. A. Belov, A. A. Burenkov, V. Chepel, A. Currie, L. DeViveiros, B. Edwards, V. Francis, C. Ghag, A. Hollingsworth, M. Horn, G. E. Kalmus, A. S. Kobyakin, A. G. Kovalenko, V. N. Lebedenko, A. Lindote, M. I. Lopes, R. Luscher, P. Majewski, A. St J. Murphy, F. Neves, S. M. Paling , et al. (12 additional authors not shown)

    Abstract: Plastic scintillators are widely used in industry, medicine and scientific research, including nuclear and particle physics. Although one of their most common applications is in neutron detection, experimental data on their response to low-energy nuclear recoils are scarce. Here, the relative scintillation efficiency for neutron-induced nuclear recoils in a polystyrene-based plastic scintillator (… ▽ More

    Submitted 9 November, 2011; originally announced November 2011.

    Comments: 8 pages, 9 figures

  16. WIMP-nucleon cross-section results from the second science run of ZEPLIN-III

    Authors: D. Yu. Akimov, H. M. Araujo, E. J. Barnes, V. A. Belov, A. Bewick, A. A. Burenkov, V. Chepel, A. Currie, L. DeViveiros, B. Edwards, C. Ghag, A. Hollingsworth, M. Horn, W. G. Jones, G. E. Kalmus, A. S. Kobyakin, A. G. Kovalenko, V. N. Lebedenko, A. Lindote, M. I. Lopes, R. Luscher, P. Majewski, A. StJ. Murphy, F. Neves, S. M. Paling , et al. (12 additional authors not shown)

    Abstract: We report experimental upper limits on WIMP-nucleon elastic scattering cross sections from the second science run of ZEPLIN-III at the Boulby Underground Laboratory. A raw fiducial exposure of 1,344 kg.days was accrued over 319 days of continuous operation between June 2010 and May 2011. A total of eight events was observed in the signal acceptance region in the nuclear recoil energy range 7-29 ke… ▽ More

    Submitted 16 December, 2011; v1 submitted 21 October, 2011; originally announced October 2011.

  17. arXiv:1110.3056  [pdf, ps, other

    physics.ins-det hep-ex

    Single electron emission in two-phase xenon with application to the detection of coherent neutrino-nucleus scattering

    Authors: E. Santos, B. Edwards, V. Chepel, H. M. Araujo, D. Yu. Akimov, E. J. Barnes, V. A. Belov, A. A. Burenkov, A. Currie, L. DeViveiros, C. Ghag, A. Hollingsworth, M. Horn, G. E. Kalmus, A. S. Kobyakin, A. G. Kovalenko, V. N. Lebedenko, A. Lindote, M. I. Lopes, R. Luscher, P. Majewski, A. StJ. Murphy, F. Neves, S. M. Paling, J. Pinto da Cunha , et al. (12 additional authors not shown)

    Abstract: We present an experimental study of single electron emission in ZEPLIN-III, a two-phase xenon experiment built to search for dark matter WIMPs, and discuss applications enabled by the excellent signal-to-noise ratio achieved in detecting this signature. Firstly, we demonstrate a practical method for precise measurement of the free electron lifetime in liquid xenon during normal operation of these… ▽ More

    Submitted 13 October, 2011; originally announced October 2011.

  18. arXiv:1106.0808  [pdf, ps, other

    astro-ph.IM physics.ins-det

    ZE3RA: The ZEPLIN-III Reduction and Analysis Package

    Authors: F. Neves, D. Yu. Akimov, H. M. Araújo, E. J. Barnes, V. A. Belov, A. A. Burenkov, V. Chepel, A. Currie, L. DeViveiros, B. Edwards, C. Ghag, A. Hollingsworth, M. Horn, G. E. Kalmus, A. S. Kobyakin, A. G. Kovalenko, V. N. Lebedenko, A. Lindote, M. I. Lopes, R. Lüscher, P. Majewski, A. St J. Murphy, S. M. Paling, J. Pinto da Cunha, R. Preece , et al. (12 additional authors not shown)

    Abstract: ZE3RA is the software package responsible for processing the raw data from the ZEPLIN-III dark matter experiment and its reduction into a set of parameters used in all subsequent analyses. The detector is a liquid xenon time projection chamber with scintillation and electroluminescence signals read out by an array of 31 photomultipliers. The dual range 62-channel data stream is optimised for the d… ▽ More

    Submitted 4 June, 2011; originally announced June 2011.

  19. arXiv:1106.0694  [pdf, ps, other

    physics.ins-det hep-ex

    Nuclear recoil scintillation and ionisation yields in liquid xenon from ZEPLIN-III data

    Authors: M. Horn, V. A. Belov, D. Yu. Akimov, H. M. Araújo, E. J. Barnes, A. A. Burenkov, V. Chepel, A. Currie, B. Edwards, C. Ghag, A. Hollingsworth, G. E. Kalmus, A. S. Kobyakin, A. G. Kovalenko, V. N. Lebedenko, A. Lindote, M. I. Lopes, R. Lüscher, P. Majewski, A. StJ. Murphy, F. Neves, S. M. Paling, J. Pinto da Cunha, R. Preece, J. J. Quenby , et al. (11 additional authors not shown)

    Abstract: Scintillation and ionisation yields for nuclear recoils in liquid xenon above 10 keVnr (nuclear recoil energy) are deduced from data acquired using broadband Am-Be neutron sources. The nuclear recoil data from several exposures to two sources were compared to detailed simulations. Energy-dependent scintillation and ionisation yields giving acceptable fits to the data were derived. Efficiency and r… ▽ More

    Submitted 17 October, 2011; v1 submitted 3 June, 2011; originally announced June 2011.

    Comments: 7 pages, 7 figures

  20. Performance of the veto detector incorporated into the ZEPLIN-III experiment

    Authors: C. Ghag, D. Yu. Akimov, H. M. Araújo, E. J. Barnes, V. A. Belov, A. A. Burenkov, V. Chepel, A. Currie, L. DeViveiros, B. Edwards, V. Francis, A. Hollingsworth, M. Horn, G. E. Kalmus, A. S. Kobyakin, A. G. Kovalenko, V. N. Lebedenko, A. Lindote, M. I. Lopes, R. Lüscher, K. Lyons, P. Majewski, A. St, J. Murphy, F. Neves , et al. (14 additional authors not shown)

    Abstract: The ZEPLIN-III experiment is operating in its second phase at the Boulby Underground Laboratory in search of dark matter WIMPs. The major upgrades to the instrument over its first science run include lower background photomultiplier tubes and installation of a plastic scintillator veto system. Performance results from the veto detector using calibration and science data in its first six months of… ▽ More

    Submitted 1 May, 2011; v1 submitted 2 March, 2011; originally announced March 2011.

    Journal ref: Astroparticle Physics 35 (2011), pp. 76-86

  21. The ZEPLIN-III Anti-Coincidence Veto Detector

    Authors: D. Yu. Akimov, H. M. Araujo, E. J. Barnes, V. A. Belov, A. A. Burenkov, V. Chepel, A. Currie, B. Edwards, V. Francis, C. Ghag, A. Hollingsworth, M. Horn, G. E. Kalmus, A. S. Kobyakin, A. G. Kovalenko, V. N. Lebedenko, A. Lindote, M. I. Lopes, R. Luscher, K. Lyons, P. Majewski, A. StJ. Murphy, F. Neves, S. M. Paling, J. Pinto da Cunha , et al. (12 additional authors not shown)

    Abstract: The design, optimisation and construction of an anti-coincidence veto detector to complement the ZEPLIN-III direct dark matter search instrument is described. One tonne of plastic scintillator is arranged into 52 bars individually read out by photomultipliers and coupled to a gadolinium-loaded passive polypropylene shield. Particular attention has been paid to radiological content. The overall aim… ▽ More

    Submitted 27 April, 2010; v1 submitted 23 April, 2010; originally announced April 2010.

    Journal ref: Astroparticle Physics 34 (2010), pp. 151-163

  22. Limits on inelastic dark matter from ZEPLIN-III

    Authors: D. Yu. Akimov, H. M. Araujo, E. J. Barnes, V. A. Belov, A. Bewick, A. A. Burenkov, R. Cashmore, V. Chepel, A. Currie, D. Davidge, J. Dawson, T. Durkin, B. Edwards, C. Ghag, A. Hollingsworth, M. Horn, A. S. Howard, A. J. Hughes, W. G. Jones, G. E. Kalmus, A. S. Kobyakin, A. G. Kovalenko, V. N. Lebedenko, A. Lindote, I. Liubarsky , et al. (21 additional authors not shown)

    Abstract: We present limits on the WIMP-nucleon cross section for inelastic dark matter derived from the 2008 run of ZEPLIN-III. Cuts, notably on scintillation pulse shape and scintillation-to-ionisation ratio, give a net exposure of 63 kg.days in the range 20-80keV nuclear recoil energy, in which 6 events are observed. Upper limits on signal rate are derived from the maximum empty patch in the data. Under… ▽ More

    Submitted 1 April, 2010; v1 submitted 29 March, 2010; originally announced March 2010.

    Comments: 4 pages, 5 figures. Updated with 1.17 ton.year DAMA results.

    Journal ref: Phys.Lett.B692:180-183,2010

  23. A model of the reflection distribution in the vacuum ultra violet region

    Authors: C. Silva, J. Pinto da Cunha, A. Pereira, M. I. Lopes, V. Chepel, V. Solovov, F. Neves

    Abstract: A reflection model with three components, a specular spike, a specular lobe and a diffuse lobe is discussed. This model was successfully applied to describe reflection of xenon scintillation light (175 nm) by PTFE and other fluoropolymers and can be used for Monte Carlo simulation and analysis of scintillation detectors. The measured data favors a Trowbridge-Reitz distribution function of ellips… ▽ More

    Submitted 6 October, 2009; originally announced October 2009.

    Journal ref: Nucl.Instrum.Meth.A619:59-62,2010

  24. arXiv:0910.1056  [pdf, ps, other

    physics.ins-det

    Reflectance of Polytetrafluoroethylene (PTFE) for Xenon Scintillation Light

    Authors: C. Silva, J. Pinto da Cunha, A. Pereira, V. Chepel, M. I. Lopes, V. Solovov

    Abstract: Gaseous and liquid xenon particle detectors are being used in a number of applications including dark matter search and neutrino-less double beta decay experiments. Polytetrafluoroethylene (PTFE) is often used in these detectors both as electrical insulator and as a light reflector to improve the efficiency of detection of scintillation photons. However, xenon emits in the vacuum ultraviolet wav… ▽ More

    Submitted 6 October, 2009; originally announced October 2009.

  25. Calibration of Photomultiplier Arrays

    Authors: F. Neves, V. Chepel, D. Yu. Akimov, H. M. Araujo, E. J. Barnes, V. A. Belov, A. A. Burenkov, A. Currie, B. Edwards, C. Ghag, M. Horn, A. J. Hughes, G. E. Kalmus, A. S. Kobyakin, A. G. Kovalenko, V. N. Lebedenko, A. Lindote, M. I. Lopes, R. Luscher, K. Lyons, P. Majewski, A. StJ. Murphy, J. Pinto da Cunha, R. Preece, J. J. Quenby , et al. (9 additional authors not shown)

    Abstract: A method is described that allows calibration and assessment of the linearity of response of an array of photomultiplier tubes. The method does not require knowledge of the photomultiplier single photoelectron response model and uses science data directly, thus eliminating the need for dedicated data sets. In this manner all photomultiplier working conditions (e.g. temperature, external fields,… ▽ More

    Submitted 15 May, 2009; originally announced May 2009.

    Comments: 15 pages, 6 figures

    Journal ref: Astropart.Phys.33:13-18,2010

  26. Limits on the spin-dependent WIMP-nucleon cross-sections from the first science run of the ZEPLIN-III experiment

    Authors: V. N. Lebedenko, H. M. Araujo, E. J. Barnes, A. Bewick, R. Cashmore, V. Chepel, D. Davidge, J. Dawson, T. Durkin, B. Edwards, C. Ghag, V. Graffagnino, M. Horn, A. S. Howard, A. J. Hughes, W. G. Jones, M. Joshi, G. E. Kalmus, A. G. Kovalenko, A. Lindote, I. Liubarsky, M. I. Lopes, R. Luscher, K. Lyons, P. Majewski , et al. (14 additional authors not shown)

    Abstract: We present new experimental constraints on the WIMP-nucleon spin-dependent elastic cross-sections using data from the first science run of ZEPLIN-III, a two-phase xenon experiment searching for galactic dark matter WIMPs based at the Boulby mine. Analysis of $\sim$450 kg$\cdot$days fiducial exposure revealed a most likely signal of zero events, leading to a 90%-confidence upper limit on the pure… ▽ More

    Submitted 27 January, 2009; originally announced January 2009.

    Comments: 4 pages, 2 figures

    Journal ref: Phys.Rev.Lett.103:151302,2009

  27. Results from the First Science Run of the ZEPLIN-III Dark Matter Search Experiment

    Authors: V. N. Lebedenko, H. M. Araujo, E. J. Barnes, A. Bewick, R. Cashmore, V. Chepel, A. Currie, D. Davidge, J. Dawson, T. Durkin, B. Edwards, C. Ghag, M. Horn, A. S. Howard, A. J. Hughes, W. G. Jones, M. Joshi, G. E. Kalmus, A. G. Kovalenko, A. Lindote, I. Liubarsky, M. I. Lopes, R. Luscher, P. Majewski, A. StJ. Murphy , et al. (13 additional authors not shown)

    Abstract: The ZEPLIN-III experiment in the Palmer Underground Laboratory at Boulby uses a 12kg two-phase xenon time projection chamber to search for the weakly interacting massive particles (WIMPs) that may account for the dark matter of our Galaxy. The detector measures both scintillation and ionisation produced by radiation interacting in the liquid to differentiate between the nuclear recoils expected… ▽ More

    Submitted 2 September, 2009; v1 submitted 5 December, 2008; originally announced December 2008.

    Comments: 12 pages, 17 figures

    Journal ref: Phys.Rev.D80:052010,2009

  28. Measurement of single electron emission in two-phase xenon

    Authors: B. Edwards, H. M. Araujo, V. Chepel, D. Cline, T. Durkin, J. Gao, C. Ghag, E. V. Korolkova, V. N. Lebedenko, A. Lindote, M. I. Lopes, R. Luscher, A. St. J. Murphy, F. Neves, W. Ooi, J. Pinto da Cunha, R. M. Preece, G. Salinas, C. Silva, V. N. Solovov, N. J. T. Smith, P. F. Smith, T. J. Sumner, C. Thorne, R. J. Walker , et al. (3 additional authors not shown)

    Abstract: We present the first measurements of the electroluminescence response to the emission of single electrons in a two-phase noble gas detector. Single ionization electrons generated in liquid xenon are detected in a thin gas layer during the 31-day background run of the ZEPLIN-II experiment, a two-phase xenon detector for WIMP dark matter searches. Both the pressure dependence and magnitude of the… ▽ More

    Submitted 6 August, 2007; originally announced August 2007.

    Comments: 11 pages, 6 figures

    Journal ref: Astropart.Phys.30:54-57,2008

  29. First limits on WIMP nuclear recoil signals in ZEPLIN-II: a two phase xenon detector for dark matter detection

    Authors: G. J. Alner, H. M. Araujo, A. Bewick, C. Bungau, B. Camanzi, M. J. Carson, R. J. Cashmore, H. Chagani, V. Chepel, D. Cline, D. Davidge, J. C. Davies, E. Daw, J. Dawson, T. Durkin, B. Edwards, T. Gamble, J. Gao, C. Ghag, A. S. Howard, W. G. Jones, M. Joshi, E. V. Korolkova, V. A. Kudryavtsev, T. Lawson , et al. (36 additional authors not shown)

    Abstract: Results are presented from the first underground data run of ZEPLIN-II, a 31 kg two phase xenon detector developed to observe nuclear recoils from hypothetical weakly interacting massive dark matter particles. Discrimination between nuclear recoils and background electron recoils is afforded by recording both the scintillation and ionisation signals generated within the liquid xenon, with the ra… ▽ More

    Submitted 31 January, 2007; v1 submitted 30 January, 2007; originally announced January 2007.

    Comments: 38 Pages, 16 Figures, (v2: corrected table 2 description)

    Journal ref: Astropart.Phys.28:287-302,2007

  30. arXiv:physics/0610286  [pdf, ps, other

    physics.ins-det astro-ph

    A survey of energy loss calculations for heavy ions between 1 and 100 keV

    Authors: A. Mangiarotti, M. I. Lopes, M. L. Benabderrahmane, V. Chepel, A. Lindote, J. Pinto da Cunha, P. Sona

    Abstract: The original Lindhard-Scharff-Schiøtt (LSS) theory and the more recent Tilinin theory for calculating the nuclear and electronic stopping powers of slow heavy ions are compared with predictions from the SRIM code by Ziegler. While little discrepancies are present for the nuclear contribution to the energy loss, large differences are found in the electronic one. When full ion recoil cascade simul… ▽ More

    Submitted 8 February, 2007; v1 submitted 31 October, 2006; originally announced October 2006.

    Comments: Presented at the 10th International Symposium on Radiation Physics, 17-22 September, 2006, Coimbra, Portugal; style corrections, small change to fig.2

    Journal ref: Nucl.Instrum.Meth.A580:114-117,2007

  31. The ZEPLIN-III dark matter detector: instrument design, manufacture and commissioning

    Authors: D. Yu. Akimov, G. J. Alner, H. M. Araujo, A. Bewick, C. Bungau, A. A. Burenkov, M. J. Carson, V. Chepel, D. Cline, D. Davidge, J. C. Davies, E. Daw, J. Dawson, T. Durkin, B. Edwards, T. Gamble, C. Chag, R. J. Hollingworth, A. S. Howard, W. G. Jones, M. Joshi, J. Kirkpatrick, A. Kovalenko, V. A. Kudryavtsev, I. S. Kuznetsov , et al. (35 additional authors not shown)

    Abstract: We present details of the technical design and manufacture of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures both the scintillation light and the ionisation charge generated in the liquid by interacting particles and radiation. The instrument design is driven by both the physics requirements and by the technology requirements surrounding the use of… ▽ More

    Submitted 19 May, 2006; originally announced May 2006.

    Comments: 25 pages, 19 figures. Submitted to Astropart. Phys. Some figures down sampled to reduce size

    Journal ref: Astropart.Phys. 27 (2007) 46-60

  32. The ZEPLIN-III dark matter detector: performance study using an end-to-end simulation tool

    Authors: H. M. Araujo, D. Yu. Akimov, G. J. Alner, A. Bewick, C. Bungau, B. Camanzi, M. J. Carson, V. Chepel, H. Chagani, D. Davidge, J. C. Davies, E. Daw, J. Dawson, T. Durkin, B. Edwards, T. Gamble, C. Ghag, R. Hollingworth, A. S. Howard, W. G. Jones, M. Joshi, J. Kirkpatrick, A. Kovalenko, V. A. Kudryavtsev, V. N. Lebedenko , et al. (31 additional authors not shown)

    Abstract: We present results from a GEANT4-based Monte Carlo tool for end-to-end simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase detector which measures both the scintillation light and the ionisation charge generated in liquid xenon by interacting particles and radiation. The software models the instrument response to radioactive backgrounds and calibration sources, includ… ▽ More

    Submitted 9 March, 2006; originally announced March 2006.

    Comments: Submitted to Astroparticle Physics

    Journal ref: Astropart.Phys. 26 (2006) 140-153

  33. arXiv:physics/0512136  [pdf

    physics.ins-det physics.space-ph

    Scintillation efficiency of liquid xenon for nuclear recoils with the energy down to 5 keV

    Authors: V. Chepel, V. Solovov, F. Neves, A. Pereira, P. J. Mendes, C. P. Silva, A. Lindote, J. Pinto da Cunha, M. I. Lopes, S. Kossionides

    Abstract: The scintillation efficiency of liquid xenon for nuclear recoils has been measured to be nearly constant in the recoil energy range from 140 keV down to 5 keV. The average ratio of the efficiency for recoils to that for gamma-rays is found to be 0.19+-0.02.

    Submitted 15 December, 2005; originally announced December 2005.

    Comments: 13 pages, 5 figures

  34. arXiv:physics/0501036  [pdf

    physics.ins-det astro-ph physics.space-ph

    Performance of a Chamber for Studying the Liquid Xenon Response to Nuclear Recoils

    Authors: V. Chepel, F. Neves, V. Solovov, A. Pereira, M. I. Lopes, J. Pinto da Cunha, P. Mendes, A. Lindote, C. P. Silva, R. Ferreira Marques, A. J. P. L. Policarpo

    Abstract: The design and performance of a 1.2 liter liquid xenon chamber equipped with 7 two-inch photomultiplier tubes, with the purpose of studying the scintillation response of xenon to gamma-rays and neutrons, is described. Measurements with gamma-rays indicate a high VUV light collection efficiency resulting in ~5.5 photoelectrons per 1 keV of deposited energy. The energy resolution (FWHM) is 18% and… ▽ More

    Submitted 14 January, 2005; v1 submitted 7 January, 2005; originally announced January 2005.

    Comments: 6 pages, 6 figures; Presented at IEEE Nuclear Science Symposium and Medical Imaging Conference, Rome 2004; Submitted to IEEE Transactions on Nuclear Science

    Journal ref: IEEETrans.Nucl.Sci.52:2793-2800,2005

  35. arXiv:physics/0307044  [pdf

    physics.optics physics.ins-det

    Measurement of the refractive index and attenuation length of liquid xenon for its scintillation light

    Authors: V. N. Solovov, V. Chepel, M. I. Lopes, A. Hitachi, R. Ferreira Marques, A. J. P. L. Policarpo

    Abstract: The attenuation length and refractive index of liquid xenon for intrinsic scintillation light (178nm) have been measured in a single experiment. The value obtained for attenuation length is 364 +- 18 mm. The refractive index is found to be 1.69 +- 0.02. Both values were measured at a temperature of 170 +- 1 K.

    Submitted 8 July, 2003; originally announced July 2003.

    Comments: 28 pages, 9 figures, accepted for publication in NIM A

    Journal ref: Nucl.Instrum.Meth. A516 (2004) 462-474

  36. arXiv:physics/0211117  [pdf

    physics.ins-det physics.med-ph

    Development of liquid xenon detectors for medical imaging

    Authors: V. Chepel, M. I. Lopes, V. Solovov, R. Ferreira Marques, A. J. P. L. Policarpo

    Abstract: In the present paper, we report on our developments of liquid xenon detectors for medical imaging, positron emission tomography and single photon imaging, in particular. The results of the studies of several photon detectors (photomultiplier tubes and large area avalanche photodiode) suitable for detection of xenon scintillation are also briefly described.

    Submitted 28 November, 2002; originally announced November 2002.

    Comments: 13 pages, 5 figures, presented on the International Workshop on Techniques and Applications of Xenon Detectors (Xenon01), ICRR, Univ. of Tokyo, Kashiwa, Japan, December 3-4, 2001 (submitted to proceedings)

  37. Low Temperature Performance of a Large Area Avalanche Photodiode

    Authors: V. N. Solovov, F. Neves, V. Chepel, M. I. Lopes, R. F. Marques, A. J. P. L. Policarpo

    Abstract: A Large Area Avalanche Photodiode (LAAPD) was studied, aiming to access its performance as light detector at low temperatures, down to -80 C. The excess noise factor, F, was measured and found to be approximately independent of the temperature. A linear dependence of F on the APD gain with a slope of 0.00239 +/- 0.00008 was observed for gains above 100. The detection of low intensity light pulse… ▽ More

    Submitted 24 October, 2002; originally announced October 2002.

    Comments: 16 pages, 7 figures; was presented at 3-rd conference "New Developments in Photodetection" Beaune, France, June 17-21, 2002; submitted to NIM

  38. arXiv:physics/0209072  [pdf

    physics.ins-det physics.med-ph

    Perspectives for Positron Emission Tomography with RPCs

    Authors: A. Blanco, V. Chepel, R. Ferreira-Marques, P. Fonte, M. I. Lopes, V. Peskov, A. Policarpo

    Abstract: In this study we address the feasibility and main properties of a positron emission tomograph (PET) based on RPCs. The concept, making use of the converter-plate principle, takes advantage of the intrinsic layered structure of RPCs and its simple and economic construction. The extremely good time and position resolutions of RPCs also allow the TOF-PET imaging technique to be considered. Monte-Ca… ▽ More

    Submitted 19 September, 2002; originally announced September 2002.

    Comments: Presented at "RPC2001-VI Workshop on Resistive Plate Chambers and Related Detectors", Coimbra, Portugal, 26-27 November 2001 (5 pages)

    Report number: LIP/02-02

  39. Detection of Scintillation Light of Liquid Xenon with a LAAPD

    Authors: V. N. Solovov, A. Hitachi, V. Chepel, M. I. Lopes, R. Ferreira Marques, A. J. P. L. Policarpo

    Abstract: First observation of liquid xenon scintillation due to alpha-particles and gamma-rays with a large area avalanche photodiode immersed in the liquid is reported. An energy resolution of 10% (FWHM) and a coincidence time resolution of less then 1 ns (FWHM) were measured with 5.5 MeV alpha-particles and 511 keV gamma-rays, respectively. The quantum efficiency of the photodiode for xenon scintillati… ▽ More

    Submitted 5 March, 2002; originally announced March 2002.

    Comments: 11 pages, 9 figures, to be published in Nuclear Instruments and Methods