Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content

Showing 1–50 of 66 results for author: Ferrer-Ribas, E

.
  1. arXiv:2407.15491  [pdf, other

    physics.ins-det

    Spatial resolution studies using point spread function extraction in optically read out Micromegas and GEM detectors

    Authors: A. Cools, E. Ferrer-Ribas, T. Papaevangelou, E. C. Pollacco, M. Lisowska, F. M. Brunbauer, E. Oliveri, F. J. Iguaz

    Abstract: Optically read out gaseous detectors are used in track reconstruction and imaging applications requiring high granularity images. Among resolution-determining factors, the amplification stage plays a crucial role and optimisations of detector geometry are pursued to maximise spatial resolution. To compare MicroPattern Gaseous Detector (MPGD) technologies, focused low-energy X-ray beams at the SOLE… ▽ More

    Submitted 22 July, 2024; originally announced July 2024.

    Comments: 22 pages, 17 figures

  2. arXiv:2406.16840  [pdf, other

    hep-ex

    A new upper limit on the axion-photon coupling with an extended CAST run with a Xe-based Micromegas detector

    Authors: CAST Collaboration, K. Altenmüller, V. Anastassopoulos, S. Arguedas-Cuendis, S. Aune, J. Baier, K. Barth, H. Bräuninger, G. Cantatore, F. Caspers, J. F. Castel, S. A. Çetin, F. Christensen, C. Cogollos, T. Dafni, M. Davenport, T. A. Decker, K. Desch, D. Díez-Ibáñez, B. Döbrich, E. Ferrer-Ribas, H. Fischer, W. Funk, J. Galán, J. A. García , et al. (40 additional authors not shown)

    Abstract: Hypothetical axions provide a compelling explanation for dark matter and could be emitted from the hot solar interior. The CERN Axion Solar Telescope (CAST) has been searching for solar axions via their back conversion to X-ray photons in a 9-T 10-m long magnet directed towards the Sun. We report on an extended run with the IAXO (International Axion Observatory) pathfinder detector, doubling the p… ▽ More

    Submitted 24 June, 2024; originally announced June 2024.

    Comments: 8 pages, 4 figures (plus 6 pages, 10 figures of supplemental material) Corresponding authors: C. Margalejo (cmargalejo@unizar.es) and J. Ruz (Jaime.Ruz@cern.ch)

  3. arXiv:2404.09727  [pdf, other

    physics.ins-det

    Using Micromegas detectors for direct dark matter searches: challenges and perspectives

    Authors: K. Altenmueller, . Antolin, D. Calvet, F. R. Candon, J. Castel, S. Cebrian, C. Cogollos, T. Dafni, D. Diez Ibanez, E. Ferrer-Ribas, J. Galan, J. A. Garcia, H. Gomez, Y. Gu, A. Ezquerro, I. G Irastorza, G. Luzon, C. Margalejo, H. Mirallas, L. Obis, A. Ortiz de Solorzano, T. Papaevangelou, O. Perez, E. Picatoste, J. Porron , et al. (5 additional authors not shown)

    Abstract: Gas time projection chambers (TPCs) with Micromegas pixelated readouts are being used in dark matter searches and other rare event searches, due to their potential in terms of low background levels, energy and spatial resolution, gain, and operational stability. Moreover, these detectors can provide precious features,such as topological information, allowing for event directionality and powerful s… ▽ More

    Submitted 15 April, 2024; originally announced April 2024.

  4. arXiv:2403.06316  [pdf, other

    physics.ins-det

    Background discrimination with a Micromegas detector prototype and veto system for BabyIAXO

    Authors: K. Altenmüller, J. F. Castel, S. Cebrián, T. Dafni, D. Díez-Ibañez, A. Ezquerro, E. Ferrer-Ribas, J. Galan, J. Galindo, J. A. García, A. Giganon, C. Goblin, I. G. Irastorza, C. Loiseau, G. Luzón, X. F. Navick, C. Margalejo, H. Mirallas, L. Obis, A. Ortiz de Solórzano, T. Papaevangelou, O. Pérez, A. Quintana, J. Ruz, J. K. Vogel

    Abstract: In this paper we present measurements performed with a Micromegas X-ray detector setup. The detector is a prototype in the context of the BabyIAXO helioscope, which is under construction to search for an emission of the hypothetical axion particle from the sun. An important component of such a helioscope is a low background X-ray detector with a high efficiency in the 1-10 keV energy range. The go… ▽ More

    Submitted 10 March, 2024; originally announced March 2024.

  5. X-ray imaging with Micromegas detectors with optical readout

    Authors: A. Cools, S. Aune, F. Beau, F. M. Brunbauer, T. Benoit, D. Desforge, E. Ferrer-Ribas, A. Kallitsopoulou, C. Malgorn, E. Oliveri, T. Papaevangelou, E. C. Pollacco, L. Ropelewski, A. Sari, F. J. Iguaz

    Abstract: In the last years, optical readout of Micromegas gaseous detectors has been achieved by implementing a Micromegas detector on a glass anode coupled to a CMOS camera. Effective X-ray radiography was demonstrated using integrated imaging approach. High granularity values have been reached for low-energy X-rays from radioactive sources and X-ray generators. Detector characterization with X-ray radi… ▽ More

    Submitted 30 March, 2023; originally announced March 2023.

    Comments: 6 pages, 4 figures, 7th International Conference on Micro Pattern Gaseous Detectors, 11-16 December 20223, Weizmann Institute of Science, Rehovot, Israel

  6. arXiv:2303.15028  [pdf, other

    hep-ex physics.ins-det

    Ultra low background Micromegas detectors for BabyIAXO solar axion search

    Authors: E. Ferrer-Ribas, K. Altenmüller, B. Biasuzzi, J. F. Castel, S. Cebrián, T. Dafni, K. Desch, D. Díez-Ibañez, J. Galán, J. Galindo, J. A. García, A. Giganon, C. Goblin, I. G. Irastorza, J. Kaminski, G. Luzón, C. Margalejo, H. Mirallas, X. F. Navick, L. Obis, A. Ortiz de Solórzano, J. von Oy, T. Papaevangelou, O. Pérez, E. Picatoste , et al. (5 additional authors not shown)

    Abstract: The International AXion Observatory (IAXO) is a large scale axion helioscope that will look for axions and axion-like particles produced in the Sun with unprecedented sensitivity. BabyIAXO is an intermediate experimental stage that will be hosted at DESY (Germany) and that will test all IAXO subsystems serving as a prototype for IAXO but at the same time as a fully-fledged helioscope with potentia… ▽ More

    Submitted 22 May, 2023; v1 submitted 27 March, 2023; originally announced March 2023.

    Comments: 4 pages, 2 figures, submitted for the proceedings of the International Conference on Micro Pattern Gaseous Detectors, December 2022, Israel

  7. Medica-Plus: a Micromegas-based proof-of-concept detector for sub-becquerel tritium activity assessment at the service of oncological research

    Authors: F. Jambon, S. Aune, P. Baron, T. Benoit, T. Bey, D. Desforge, E. Ferrer-Ribas, A. Grabas, M. Kebbiri, I. Mandjavidze, T. Papaevangelou, M. Riallot, M. Vandenbroucke, F. Beau, V. Dive, C. Malgorn, F. Malloggi, A. Rousselot, F. Carrel, M. Trocmé

    Abstract: To fulfill needs in oncological research a new Micromegas detector has been developed to follow radiolabelled drugs in living organisms at the single cell level. This article describes the proof-of-concept of such a detector and compares its ability to detect and assess sub-becquerel \tritium~activities with a commercial $β$-imager

    Submitted 20 September, 2021; originally announced September 2021.

    Comments: 14 pages, to be submitted to NIMA

  8. arXiv:2109.05863  [pdf, other

    physics.comp-ph physics.data-an physics.ins-det

    REST-for-Physics, a ROOT-based framework for event oriented data analysis and combined Monte Carlo response

    Authors: Konrad Altenmüller, Susana Cebrián, Theopisti Dafni, David Díez-Ibáñez, Javier Galán, Javier Galindo, Juan Antonio García, Igor G. Irastorza, Gloria Luzón, Cristina Margalejo, Hector Mirallas, Luis Obis, Oscar Pérez, Ke Han, Kaixiang Ni, Yann Bedfer, Barbara Biasuzzi, Esther Ferrer-Ribas, Damien Neyret, Thomas Papaevangelou, Cristian Cogollos, Eduardo Picatoste

    Abstract: The REST-for-Physics (Rare Event Searches Toolkit for Physics) framework is a ROOT-based solution providing the means to process and analyze experimental or Monte Carlo event data. Special care has been taken on the traceability of the code and the validation of the results produced within the framework, together with the connectivity between code and data stored registered through specific versio… ▽ More

    Submitted 19 November, 2021; v1 submitted 13 September, 2021; originally announced September 2021.

    Comments: 27 pages, 14 figures, prepared for submission to Computer Physics Communications

  9. arXiv:2010.12076  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Conceptual Design of BabyIAXO, the intermediate stage towards the International Axion Observatory

    Authors: A. Abeln, K. Altenmüller, S. Arguedas Cuendis, E. Armengaud, D. Attié, S. Aune, S. Basso, L. Bergé, B. Biasuzzi, P. T. C. Borges De Sousa, P. Brun, N. Bykovskiy, D. Calvet, J. M. Carmona, J. F. Castel, S. Cebrián, V. Chernov, F. E. Christensen, M. M. Civitani, C. Cogollos, T. Dafní, A. Derbin, K. Desch, D. Díez, M. Dinter , et al. (101 additional authors not shown)

    Abstract: This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for… ▽ More

    Submitted 4 March, 2021; v1 submitted 22 October, 2020; originally announced October 2020.

    Comments: 77 pages, 49 figures. Prepared for submission to JHEP. Third version after referees comments

  10. Physics potential of the International Axion Observatory (IAXO)

    Authors: E. Armengaud, D. Attie, S. Basso, P. Brun, N. Bykovskiy, J. M. Carmona, J. F. Castel, S. Cebrián, M. Cicoli, M. Civitani, C. Cogollos, J. P. Conlon, D. Costa, T. Dafni, R. Daido, A. V. Derbin, M. A. Descalle, K. Desch, I. S. Dratchnev, B. Döbrich, A. Dudarev, E. Ferrer-Ribas, I. Fleck, J. Galán, G. Galanti , et al. (66 additional authors not shown)

    Abstract: We review the physics potential of a next generation search for solar axions: the International Axion Observatory (IAXO). Endowed with a sensitivity to discover axion-like particles (ALPs) with a coupling to photons as small as $g_{aγ}\sim 10^{-12}$ GeV$^{-1}$, or to electrons $g_{ae}\sim$10$^{-13}$, IAXO has the potential to find the QCD axion in the 1 meV$\sim$1 eV mass range where it solves the… ▽ More

    Submitted 6 June, 2019; v1 submitted 19 April, 2019; originally announced April 2019.

    Comments: Prepared for submission to JCAP; new version with very minor corrections after referee review

  11. arXiv:1903.03979  [pdf, ps, other

    physics.ins-det hep-ex

    Topological background discrimination in the PandaX-III neutrinoless double beta decay experiment

    Authors: J Galan, X Chen, H Du, C Fu, K Giboni, F Giuliani, K Han, B Jiang, X Ji, H Lin, Y Lin, J Liu, K Ni, X Ren, S Wang, S Wu, C Xie, Y Yang, D Zhang, T Zhang, L Zhao, S Aune, Y Bedfer, E Berthoumieux, D Calvet , et al. (42 additional authors not shown)

    Abstract: The PandaX-III experiment plans to search for neutrinoless double beta decay (0$νββ$) of $^{136}$Xe in the China JinPing underground Laboratory (CJPL). The experiment will use a high pressure gaseous Time Projection Chamber (TPC) to register both the energy and the electron track topology of an event. This article is devoted to the software side of the experiment. As software tool we use REST, a f… ▽ More

    Submitted 22 July, 2019; v1 submitted 10 March, 2019; originally announced March 2019.

    Comments: 40 pages, 15 figures. Prepared for submission to Journal of Physics G

  12. arXiv:1808.00066  [pdf, other

    hep-ex physics.ins-det

    Improved Search for Solar Chameleons with a GridPix Detector at CAST

    Authors: V. Anastassopoulos, S. Aune, K. Barth, A. Belov, H. Bräuninger, G. Cantatore, J. M. Carmona, J. F. Castel, S. A. Cetin, F. Christensen, T. Dafni, M. Davenport, A. Dermenev, K. Desch, B. Döbrich, C. Eleftheriadis, G. Fanourakis, E. Ferrer-Ribas, H. Fischer, W. Funk, J. A. García, A. Gardikiotis, J. G. Garza, E. N. Gazis, T. Geralis , et al. (44 additional authors not shown)

    Abstract: We report on a new search for solar chameleons with the CERN Axion Solar Telescope (CAST). A GridPix detector was used to search for soft X-ray photons in the energy range from 200 eV to 10 keV from converted solar chameleons. No signiffcant excess over the expected background has been observed in the data taken in 2014 and 2015. We set an improved limit on the chameleon photon coupling,… ▽ More

    Submitted 8 November, 2018; v1 submitted 31 July, 2018; originally announced August 2018.

    Comments: 19 pages, 12 figures, 3 tables

  13. arXiv:1705.02290  [pdf, other

    hep-ex physics.ins-det

    New CAST Limit on the Axion-Photon Interaction

    Authors: CAST collaboration, V. Anastassopoulos, S. Aune, K. Barth, A. Belov, H. Brauninger, G. Cantatore, J. M. Carmona, J. F. Castel, S. A. Cetin, F. Christensen, J. I. Collar, T. Dafni, M. Davenport, T. A. Decker, A. Dermenev, K. Desch, C. Eleftheriadis, G. Fanourakis, E. Ferrer-Ribas, H. Fischer, J. A. Garcia, A. Gardikiotis, J. G. Garza, E. N. Gazis , et al. (42 additional authors not shown)

    Abstract: During 2003--2015, the CERN Axion Solar Telescope (CAST) has searched for $a\toγ$ conversion in the 9 T magnetic field of a refurbished LHC test magnet that can be directed toward the Sun. In its final phase of solar axion searches (2013--2015), CAST has returned to evacuated magnet pipes, which is optimal for small axion masses. The absence of a significant signal above background provides a worl… ▽ More

    Submitted 20 December, 2017; v1 submitted 5 May, 2017; originally announced May 2017.

    Comments: Second version after referees comments (post-print). Published version available Open Access at https://www.nature.com/articles/nphys4109

    Journal ref: Nature Phys. 13 (2017) 584-590

  14. arXiv:1610.08883  [pdf, other

    physics.ins-det hep-ex nucl-ex

    PandaX-III: Searching for Neutrinoless Double Beta Decay with High Pressure $^{136}$Xe Gas Time Projection Chambers

    Authors: Xun Chen, Changbo Fu, Javier Galan, Karl Giboni, Franco Giuliani, Linghui Gu, Ke Han, Xiangdong Ji, Heng Lin, Jianglai Liu, Kaixiang Ni, Hiroki Kusano, Xiangxiang Ren, Shaobo Wang, Yong Yang, Dan Zhang, Tao Zhang, Li Zhao, Xiangming Sun, Shouyang Hu, Siyu Jian, Xinglong Li, Xiaomei Li, Hao Liang, Huanqiao Zhang , et al. (45 additional authors not shown)

    Abstract: Searching for the Neutrinoless Double Beta Decay (NLDBD) is now regarded as the topmost promising technique to explore the nature of neutrinos after the discovery of neutrino masses in oscillation experiments. PandaX-III (Particle And Astrophysical Xenon Experiment III) will search for the NLDBD of $^{136}$Xe at the China Jin Ping underground Laboratory (CJPL). In the first phase of the experiment… ▽ More

    Submitted 27 October, 2016; v1 submitted 27 October, 2016; originally announced October 2016.

  15. arXiv:1610.02396  [pdf, other

    physics.ins-det astro-ph.CO astro-ph.IM hep-ex

    Readout technologies for directional WIMP Dark Matter detection

    Authors: J. B. R. Battat, I. G. Irastorza, A. Aleksandrov, M. Ali Guler, T. Asada, E. Baracchini, J. Billard, G. Bosson, O. Bourrion, J. Bouvier, A. Buonaura, K. Burdge, S. Cebrian, P. Colas, L. Consiglio, T. Dafni, N. D'Ambrosio, C. Deaconu, G. De Lellis, T. Descombes, A. Di Crescenzo, N. Di Marco, G. Druitt, R. Eggleston, E. Ferrer-Ribas , et al. (68 additional authors not shown)

    Abstract: The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial… ▽ More

    Submitted 6 October, 2016; originally announced October 2016.

    Comments: 58 pages, 26 figures, accepted by Physics Reports

    Journal ref: Physics Reports 662 (2016) pp. 1-46

  16. arXiv:1609.06459  [pdf, ps, other

    physics.ins-det hep-ex

    Micromegas for dark matter searches: CAST/IAXO & TREX-DM

    Authors: J. G. Garza, S. Aune, J. F. Castel, S. Cebrián, T. Dafni, E. Ferrer-Ribas, J. Galán, J. A. García, I. Giomataris, F. J. Iguaz, I. G. Irastorza, G. Luzón, H. Mirallas, T. Papaevangelou, A. Peiró, A. Tomás, T. Vafeiadis

    Abstract: The most compelling candidates for Dark Matter to day are WIMPs and axions. The applicability of gasesous Time Projection Chambers (TPCs) with Micromesh Gas Structures (Micromegas) to the search of these particles is explored within this work. Both particles would produce an extremely low rate at very low energies in particle detectors. Micromegas detectors can provide both low background rates an… ▽ More

    Submitted 21 September, 2016; originally announced September 2016.

    Comments: 4 pages, 5 figures. 4th International Conference on Micro Pattern Gaseous Detectors. (Trieste, 12-15 October 2015)

  17. arXiv:1601.00123  [pdf, ps, other

    physics.ins-det hep-ex

    Fast Timing for High-Rate Environments with Micromegas

    Authors: Thomas Papaevangelou, Daniel Desforge, Esther Ferrer-Ribas, Ioannis Giomataris, Cyprien Godinot, Diego Gonzalez Diaz, Thomas Gustavsson, Mariam Kebbiri, Eraldo Oliveri, Filippo Resnati, Leszek Ropelewski, Georgios Tsiledakis, Rob Veenhof, Sebastian White

    Abstract: The current state of the art in fast timing resolution for existing experiments is of the order of 100 ps on the time of arrival of both charged particles and electromagnetic showers. Current R&D on charged particle timing is approaching the level of 10 ps but is not primarily directed at sustained performance at high rates and under high radiation (as would be needed for HL-LHC pileup mitigation)… ▽ More

    Submitted 12 January, 2016; v1 submitted 1 January, 2016; originally announced January 2016.

    Comments: MPGD2015 (4th Conference on Micro-Pattern Gaseous Detectors, Trieste, Italy, 12 - 15 October, 2015). 5 pages, 8 figures

  18. arXiv:1509.06190  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    A Micromegas-based low-background x-ray detector coupled to a slumped-glass telescope for axion research

    Authors: F. Aznar, J. Castel, F. E. Christensen, T. Dafni, T. A. Decker, E. Ferrer-Ribas, J. A. Garcia, I. Giomataris, J. G. Gracia, C. J. Hailey, R. M. Hill, F. J. Iguaz, I. G. Irastorza, A. C. Jakobsen, G. Luzon, H. Mirallas, T. Papaevangelou, M. J. Pivovaroff, J. Ruz, T. Vafeiadis, J. K. Vogel

    Abstract: We report on the design, construction and operation of a low background x-ray detection line composed of a shielded Micromegas (micromesh gaseous structure) detector of the microbulk technique. The detector is made from radiopure materials and is placed at the focal point of a $\sim$~5 cm diameter, 1.3 m focal-length, cone-approximation Wolter I x-ray telescope (XRT) comprised of thermally-formed… ▽ More

    Submitted 21 September, 2015; originally announced September 2015.

    Comments: 21 pages, 16 figures

  19. arXiv:1508.03006  [pdf, other

    astro-ph.IM physics.ins-det

    Exploring 0.1-10$\,$eV axions with a new helioscope concept

    Authors: J. Galán, T. Dafni, E. Ferrer-Ribas, I. Giomataris, F. J. Iguaz, I. G. Irastorza, J. A. García, J. Gracia, G. Luzón, T. Papaevangelou, J. Redondo, A. Tomás

    Abstract: We explore the possibility to develop a new axion helioscope type, sensitive to the higher axion mass region favored by axion models. We propose to use a low background large volume TPC immersed in an intense magnetic field. Contrary to traditional tracking helioscopes, this detection technique takes advantage of the capability to directly detect the photons converted on the buffer gas which defin… ▽ More

    Submitted 7 September, 2015; v1 submitted 12 August, 2015; originally announced August 2015.

    Comments: prepared for submission to JCAP

  20. arXiv:1504.05865  [pdf, other

    astro-ph.IM nucl-ex physics.ins-det

    First detection of tracks of radon progeny recoils by MIMAC

    Authors: Q. Riffard, D. Santos, G. Bosson, O. Bourrion, T. Descombes, C. Fourel, O. Guillaudin, J. -F. Muraz, P. Colas, E. Ferrer-Ribas, I. Giomataris, J. Busto, D. Fouchez, C. Tao, L. Lebreton, D. Maire

    Abstract: The MIMAC experiment is a $μ$-TPC matrix project for directional dark matter search. Directional detection is a strategy based on the measurement of the WIMP flux anisotropy due to the solar system motion with respect to the dark matter halo. The main purpose of MIMAC project is the measurement of the energy and the direction of nuclear recoils in 3D produced by elastic scattering of WIMPs. Since… ▽ More

    Submitted 20 June, 2017; v1 submitted 22 April, 2015; originally announced April 2015.

    Comments: 11 pages, 12 figures, submitted to PRD

  21. Accurate gamma and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atmospheres

    Authors: Diego Gonzalez-Diaz, V. Alvarez, F. I. G. Borges, M. Camargo, S. Carcel, S. Cebrian, A. Cervera, C. A. N. Conde, T. Dafni, J. Diaz, R. Esteve, L. M. P. Fernandes, P. Ferrario, A. L. Ferreira, E. D. C. Freitas, V. M. Gehman, A. Goldschmidt, J. J. Gomez-Cadenas, R. M. Gutierrez, J. Hauptman, J. A. Hernando Morata, D. C. Herrera, I. G. Irastorza, L. Labarga, A. Laing , et al. (58 additional authors not shown)

    Abstract: We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275 MeV) in conjunction with the accurate tracking of the associated electrons. When operated at such a high pressure and in 1%-admixtures, trimethylamine (TMA) endows Xenon with an extremely low electron diffusion (1.3 +-0.13 mm-sigma (longitudinal)… ▽ More

    Submitted 17 June, 2015; v1 submitted 14 April, 2015; originally announced April 2015.

  22. Lessons from the operation of the "Penning-Fluorescent" TPC and prospects

    Authors: Diego Gonzalez-Diaz, F. Aznar, J. Castel, S. Cebrian, T. Dafni, J. A. Garcia, J. G. Garza, H. Gomez, D. C. Herrera, F. J. Iguaz, I. G. Irastorza, A. Lagraba, G. Luzon, A. Rodriguez, E. Ruiz-Choliz, L. Segui, A. Tomas E. Ferrer-Ribas, I. Giomataris

    Abstract: We have recently reported the development of a new type of high-pressure Xenon time projection chamber operated with an ultra-low diffusion mixture and that simultaneously displays Penning effect and fluorescence in the near-visible region (300 nm). The concept, dubbed `Penning-Fluorescent' TPC, allows the simultaneous reconstruction of primary charge and scintillation with high topological and ca… ▽ More

    Submitted 15 May, 2015; v1 submitted 14 April, 2015; originally announced April 2015.

  23. arXiv:1503.05107  [pdf, other

    physics.ins-det nucl-ex

    Low Background Micromegas in CAST

    Authors: J. G. Garza, S. Aune, D. Calvet, J. F. Castel, F. E. Christensen, T. Dafni, M. Davenport, T. Decker, E. Ferrer-Ribas, J. Galán, J. A. García, I. Giomataris, R. M. Hill, F. J. Iguaz, I. G. Irastorza, A. C. Jakobsen, D. Jourde, H. Mirallas, I. Ortega, T. Papaevangelou, M. J. Pivovaroff, J. Ruz, A. Tomás, T. Vafeiadis, J. K. Vogel

    Abstract: Solar axions could be converted into x-rays inside the strong magnetic field of an axion helioscope, triggering the detection of this elusive particle. Low background x-ray detectors are an essential component for the sensitivity of these searches. We report on the latest developments of the Micromegas detectors for the CERN Axion Solar Telescope (CAST), including technological pathfinder activiti… ▽ More

    Submitted 17 March, 2015; originally announced March 2015.

    Comments: 6 pages, 3 figures, Large TPC Conference 2014, Paris

  24. arXiv:1503.04561  [pdf, other

    astro-ph.SR hep-ph physics.ins-det

    Search for chameleons with CAST

    Authors: V. Anastassopoulos, M. Arik, S. Aune, K. Barth, A. Belov, H. Bräuninger, G. Cantatore, J. M. Carmona, S. A. Cetin, F. Christensen, J. I. Collar, T. Dafni, M. Davenport, K. Desch, A. Dermenev, C. Eleftheriadis, G. Fanourakis, E. Ferrer-Ribas, P. Friedrich, J. Galán, J. A. García, A. Gardikiotis, J. G. Garza, E. N. Gazis, T. Geralis , et al. (39 additional authors not shown)

    Abstract: In this work we present a search for (solar) chameleons with the CERN Axion Solar Telescope (CAST). This novel experimental technique, in the field of dark energy research, exploits both the chameleon coupling to matter ($β_{\rm m}$) and to photons ($β_γ$) via the Primakoff effect. By reducing the X-ray detection energy threshold used for axions from 1$\,$keV to 400$\,$eV CAST became sensitive to… ▽ More

    Submitted 18 March, 2016; v1 submitted 16 March, 2015; originally announced March 2015.

    Comments: 8 pages, 12 figures

  25. arXiv:1503.00610  [pdf, ps, other

    hep-ex physics.ins-det

    New solar axion search in CAST with $^4$He filling

    Authors: M. Arik, S. Aune, K. Barth, A. Belov, H. Bräuninger, J. Bremer, V. Burwitz, G. Cantatore, J. M. Carmona, S. A. Cetin, J. I. Collar, E. Da Riva, T. Dafni, M. Davenport, A. Dermenev, C. Eleftheriadis, N. Elias, G. Fanourakis, E. Ferrer-Ribas, J. Galán, J. A. García, A. Gardikiotis, J. G. Garza, E. N. Gazis, T. Geralis , et al. (38 additional authors not shown)

    Abstract: The CERN Axion Solar Telescope (CAST) searches for $a\toγ$ conversion in the 9 T magnetic field of a refurbished LHC test magnet that can be directed toward the Sun. Two parallel magnet bores can be filled with helium of adjustable pressure to match the X-ray refractive mass $m_γ$ to the axion search mass $m_a$. After the vacuum phase (2003--2004), which is optimal for $m_a\lesssim0.02$ eV, we use… ▽ More

    Submitted 11 June, 2015; v1 submitted 2 March, 2015; originally announced March 2015.

    Comments: CAST Collaboration 6 pages 3 figures

    Journal ref: Phys. Rev. D 92, 021101 (2015)

  26. arXiv:1501.01466  [pdf, other

    astro-ph.IM hep-ex physics.ins-det

    Lowering the background level and the energy threshold of Micromegas x-ray detectors for axion searches

    Authors: F. J. Iguaz, S. Aune, F. Aznar, J. F. Castel, T. Dafni, M. Davenport, E. Ferrer-Ribas, J. Galan, J. A. Garcia, J. G. Garza, I. Giomataris, I. G. Irastorza, T. Papaevangelou, A. Rodriguez, A. Tomas, T. Vafeiadis, S. C. Yildiz

    Abstract: Axion helioscopes search for solar axions by their conversion in x-rays in the presence of high magnetic fields. The use of low background x-ray detectors is an essential component contributing to the sensitivity of these searches. In this work, we review the recent advances on Micromegas detectors used in the CERN Axion Solar Telescope (CAST) and proposed for the future International Axion Observ… ▽ More

    Submitted 7 January, 2015; originally announced January 2015.

    Comments: Proceedings of 3rd International Conference on Technology and Instrumentation in Particle Physics (TIPP 2014)

    Journal ref: Pos(TIPP2014) 295

  27. arXiv:1401.3233  [pdf, other

    physics.ins-det hep-ex

    Conceptual Design of the International Axion Observatory (IAXO)

    Authors: E. Armengaud, F. T. Avignone, M. Betz, P. Brax, P. Brun, G. Cantatore, J. M. Carmona, G. P. Carosi, F. Caspers, S. Caspi, S. A. Cetin, D. Chelouche, F. E. Christensen, A. Dael, T. Dafni, M. Davenport, A. V. Derbin, K. Desch, A. Diago, B. Döbrich, I. Dratchnev, A. Dudarev, C. Eleftheriadis, G. Fanourakis, E. Ferrer-Ribas , et al. (63 additional authors not shown)

    Abstract: The International Axion Observatory (IAXO) will be a forth generation axion helioscope. As its primary physics goal, IAXO will look for axions or axion-like particles (ALPs) originating in the Sun via the Primakoff conversion of the solar plasma photons. In terms of signal-to-noise ratio, IAXO will be about 4-5 orders of magnitude more sensitive than CAST, currently the most powerful axion heliosc… ▽ More

    Submitted 14 January, 2014; originally announced January 2014.

    Comments: 47 pages, submitted to JINST

    Journal ref: JINST 9 (2014) T05002

  28. X-ray detection with Micromegas with background levels below 10$^{-6}$ keV$^{-1}$cm$^{-2}$s$^{-1}$

    Authors: S. Aune, F. Aznar, D. Calvet, T. Dafni, A. Diago, F. Druillole, G. Fanourakis, E. Ferrer-Ribas, J. Galán, J. A. García, A. Gardikiotis, J. G. Garza, T. Geralis, I. Giomataris, H. Gómez, D. González-Díaz, D. C. Herrera, F. J. Iguaz, I. G. Irastorza, D. Jourde, G. Luzón, H. Mirallas, J. P. Mols, T. Papaevangelou, A. Rodríguez , et al. (4 additional authors not shown)

    Abstract: Micromegas detectors are an optimum technological choice for the detection of low energy x-rays. The low background techniques applied to these detectors yielded remarkable background reductions over the years, being the CAST experiment beneficiary of these developments. In this document we report on the latest upgrades towards further background reductions and better understanding of the detector… ▽ More

    Submitted 16 December, 2013; originally announced December 2013.

    Journal ref: JINST 8 (2013) C12042

  29. Characterization of a medium size Xe/TMA TPC instrumented with microbulk Micromegas, using low-energy $γ$-rays

    Authors: The NEXT collaboration, V. Alvarez, F. I. G. M. Borges, S. Carcel, J. Castel, S. Cebrian, A. Cervera, C. A. N. Conde, T. Dafni, T. H. V. T. Dias, J. Diaz, M. Egorov, R. Esteve, P. Evtoukhovitch, L. M. P. Fernandes, P. Ferrario, A. L. Ferreira, E. D. C. Freitas, V. M. Gehman, A. Gil, A. Goldschmidt, H. Gomez, J. J. Gomez-Cadenas, D. Gonzalez-Diaz, R. M. Gutierrez , et al. (65 additional authors not shown)

    Abstract: NEXT-MM is a general-purpose high pressure (10 bar, $\sim25$ l active volume) Xenon-based TPC, read out in charge mode with an 8 cm $\times$8 cm-segmented 700 cm$^2$ plane (1152 ch) of the latest microbulk-Micromegas technology. It has been recently commissioned at University of Zaragoza as part of the R&D of the NEXT $0νββ$ experiment, although the experiment's first stage is currently being buil… ▽ More

    Submitted 17 November, 2013; v1 submitted 14 November, 2013; originally announced November 2013.

    Comments: 22 pages, 13 figures

  30. Description and commissioning of NEXT-MM prototype: first results from operation in a Xenon-Trimethylamine gas mixture

    Authors: NEXT Collaboration, V. Álvarez, F. Aznar, F. I. G. M. Borges, D. Calvet, S. Cárcel, J. Castel, S. Cebrián, A. Cervera, C. A. N. Conde, T. Dafni, T. H. V. T. Dias, J. Díaz, F. Druillole, M. Egorov, R. Esteve, P. Evtoukhovitch, L. M. P. Fernandes, P. Ferrario, A. L. Ferreira, E. Ferrer-Ribas, E. D. C. Freitas, V. M. Gehman, A. Gil, I. Giomataris , et al. (60 additional authors not shown)

    Abstract: A technical description of NEXT-MM and its commissioning and first performance is reported. Having an active volume of ~35 cm drift $\times$ 28 cm diameter, it constitutes the largest Micromegas-read TPC operated in Xenon ever constructed, made by a sectorial arrangement of the 4 largest single wafers manufactured with the Microbulk technique to date. It is equipped with a suitably pixelized reado… ▽ More

    Submitted 27 November, 2013; v1 submitted 13 November, 2013; originally announced November 2013.

    Comments: 22 pages, 9 figures

  31. Low background x-ray detection with Micromegas for axion research

    Authors: S. Aune, J. F. Castel, T. Dafni, M. Davenport, G. Fanourakis, E. Ferrer-Ribas, J. Galan, J. A. Garcia, A. Gardikiotis, T. Geralis, I. Giomataris, H. Gomez, J. G. Garza, D. C. Herrera, F. J. Iguaz, I. G. Irastorza, D. Jourde, G. Luzon, J. P. Mols, T. Papaevangelou, A. Rodriguez, J. Ruz, L. Segui, A. Tomas, T. Vafeiadis , et al. (1 additional authors not shown)

    Abstract: Axion helioscopes aim at the detection of solar axions through their conversion into x-rays in laboratory magnetic fields. The use of low background x-ray detectors is an essential component contributing to the sensitivity of these searches. Here we review the recent advances on Micromegas detectors used in the CERN Axion Solar Telescope (CAST) and proposed for the future International Axion Obser… ▽ More

    Submitted 12 October, 2013; originally announced October 2013.

    Comments: 26 pages, 21 figures

    Journal ref: S Aune et al 2014 JINST 9 P010011

  32. Piggyback resistive Micromegas

    Authors: D. Attié, A. Chaus, D. Durand, D. Deforges E. Ferrer-Ribas, J. Galán, Y. Giomataris, A. Gongadze, F. J. Iguaz, F. Jeanneau, R. de Oliveira, T. Papaevangelou, A. Peyaud, A. Teixeira

    Abstract: Piggyback Micromegas consists in a novel readout architecture where the anode element is made of a resistive layer on a ceramic substrate. The resistive layer is deposited on the thin ceramic substrate by an industrial process which provides large dynamic range of resistivity (10$^6$ to 10$^{10}$\,M$Ω$/square). The particularity of this new structure is that the active part is entirely dissociated… ▽ More

    Submitted 4 October, 2013; originally announced October 2013.

    Comments: 7 pages, prepared for the MPGD 2013 conference

  33. arXiv:1307.1985  [pdf, ps, other

    hep-ex astro-ph.IM physics.ins-det

    CAST solar axion search with 3^He buffer gas: Closing the hot dark matter gap

    Authors: M. Arik, S. Aune, K. Barth, A. Belov, S. Borghi, H. Brauninger, G. Cantatore, J. M. Carmona, S. A. Cetin, J. I. Collar, E. Da Riva, T. Dafni, M. Davenport, C. Eleftheriadis, N. Elias, G. Fanourakis, E. Ferrer-Ribas, P. Friedrich, J. Galan, J. A. Garcia, A. Gardikiotis, J. G. Garza, E. N. Gazis, T. Geralis, E. Georgiopoulou , et al. (50 additional authors not shown)

    Abstract: The CERN Axion Solar Telescope (CAST) has finished its search for solar axions with 3^He buffer gas, covering the search range 0.64 eV < m_a <1.17 eV. This closes the gap to the cosmological hot dark matter limit and actually overlaps with it. From the absence of excess X-rays when the magnet was pointing to the Sun we set a typical upper limit on the axion-photon coupling of g_ag < 3.3 x 10^{-10}… ▽ More

    Submitted 15 September, 2014; v1 submitted 8 July, 2013; originally announced July 2013.

    Comments: 5 pages, 2 figures. Last version uploaded

    Journal ref: Phys. Rev. Lett. 112, 091302 (2014)

  34. arXiv:1304.2057  [pdf, other

    physics.ins-det physics.comp-ph

    Characterization and simulation of resistive-MPGDs with resistive strip and layer topologies

    Authors: J. Galan, D. Attie, A. Chaus, P. Colas, A. Delbart, E. Ferrer-Ribas, I. Giomataris, F. J. Iguaz, A. Gongadze, T. Papaevangelou, A. Peyaud

    Abstract: The use of resistive technologies to MPGD detectors is taking advantage for many new applications, including high rate and energetic particle flux scenarios. The recent use of these technologies in large area detectors makes necessary to understand and characterize the response of this type of detectors in order to optimize or constrain the parameters used in its production, material resistivity,… ▽ More

    Submitted 7 April, 2013; originally announced April 2013.

    Comments: VCI2013 conference

  35. arXiv:1304.2053  [pdf, other

    physics.ins-det hep-ex

    Ageing studies of resistive Micromegas detectors for the HL-LHC

    Authors: J. Galan, D. Attie, E. Ferrer-Ribas, A. Giganon, I. Giomataris, S. Herlant, F. Jeanneau, A. Peyaud, Ph. Schune, T. Alexopoulos, M. Byszewski, G. Iakovidis, P. Iengo, K. Ntekas, S. Leontsinis, R. de Oliveira, Y. Tsipolitis, J. Wotschack

    Abstract: Resistive-anode Micromegas detectors are in development since several years, in an effort to solve the problem of sparks when working in high flux and high radiations environment like in the HL-LHC (ten times the luminosity of the LHC). They have been chosen as one of the technologies that will be part of the ATLAS New Small Wheel project (forward muon system). An ageing study is mandatory to asse… ▽ More

    Submitted 7 April, 2013; originally announced April 2013.

    Comments: proceedings VCI2013 conference

  36. Micromegas-TPC operation at high pressure in Xenon-trimethylamine mixtures

    Authors: D. C. Herrera, S. Cebrián, T. Dafni, E. Ferrer-Ribas, I. Giomataris, D. Gonzalez-Diaz, H. Gómez, F. J. Iguaz, I. G. Irastorza, G. Luzon, A. Rodríguez, L. Segui, A. Tomás

    Abstract: We present in this work measurements performed with a small Micromegas-TPC using a xenon-trimethylamine (Xe-TMA) Penning-mixture as filling gas. Measurements of gas gain and energy resolutions for 22.1 keV X-rays are presented, spanning several TMA concentrations and pressures between 1 and 10 bar. Across this pressure range, the best energy resolution and largest increase in gain at constant fiel… ▽ More

    Submitted 22 March, 2013; originally announced March 2013.

    Comments: 8 pages, 7 figures, proceeding

  37. arXiv:1302.3273  [pdf, ps, other

    physics.ins-det hep-ex

    IAXO - The International Axion Observatory

    Authors: J. K. Vogel, F. T. Avignone, G. Cantatore, J. M. Carmona, S. Caspi, S. A. Cetin, F. E. Christensen, A. Dael, T. Dafni, M. Davenport, A. V. Derbin, K. Desch, A. Diago, A. Dudarev, C. Eleftheriadis, G. Fanourakis, E. Ferrer-Ribas, J. Galan, J. A. Garcia, J. G. Garza, T. Geralis, B. Gimeno, I. Giomataris, S. Gninenko, H. Gomez , et al. (39 additional authors not shown)

    Abstract: The International Axion Observatory (IAXO) is a next generation axion helioscope aiming at a sensitivity to the axion-photon coupling of a few 10^{-12} GeV^{-1}, i.e. 1-1.5 orders of magnitude beyond sensitivities achieved by the currently most sensitive axion helioscope, the CERN Axion Solar Telescope (CAST). Crucial factors in improving the sensitivity for IAXO are the increase of the magnetic f… ▽ More

    Submitted 13 February, 2013; originally announced February 2013.

    Comments: 6 pages, 1 figure, Contribution to the 8th Patras Workshop on Axions, WIMPs and WISPs, Chicago, IL, USA, 2012

  38. arXiv:1301.7648  [pdf, other

    physics.ins-det hep-ex physics.acc-ph

    An ageing study of resistive micromegas for the HL-LHC environment

    Authors: J. Galán, D. Attié, E. Ferrer-Ribas, A. Giganon, I. Giomataris, S. Herlant, F. Jeanneau, A. Peyaud, Ph. Schune, T. Alexopoulos, M. Byszewski, G. Iakovidis, P. Iengo, K. Ntekas, S. Leontsinis, R. de Oliveira, Y. Tsipolitis, J. Wotschack

    Abstract: Resistive-anode micromegas detectors are in development since several years, in an effort to solve the problem of sparks when working at high flux and high ionizing radiation like in the HL-LHC (up to ten times the luminosity of the LHC). They have been chosen as one of the technologies that will be part of the ATLAS New Small Wheel project (forward muon system). An ageing study is mandatory to as… ▽ More

    Submitted 31 January, 2013; originally announced January 2013.

  39. arXiv:1210.3287  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Micromegas-TPC operation at high pressure in xenon-trimethylamine mixtures

    Authors: S. Cebrián, T. Dafni, E. Ferrer-Ribas, I. Giomataris, D. Gonzalez-Diaz, H. Gómez, D. C. Herrera, F. J. Iguaz, I. G. Irastorza, G. Luzon, A. Rodríguez, L. Segui, A. Tomás

    Abstract: In this work we present a systematic study of Micromegas detectors in high pressure gaseous Xenon using trimethylamine (TMA) as quencher gas. Gas gains and energy resolutions for 22.1 keV X-rays are measured for pressures between 1 and 10 bar and various relative concentrations of TMA from 0.3 % to 15 %. We observe stable operation at all pressures, and a strongly enhanced gas gain, suggestive of… ▽ More

    Submitted 23 November, 2012; v1 submitted 11 October, 2012; originally announced October 2012.

  40. arXiv:1209.6347  [pdf, other

    hep-ex astro-ph.CO

    Results and perspectives of the solar axion search with the CAST experiment

    Authors: E. Ferrer-Ribas, M. Arik, S. Aune, K. Barth, A. Belov, S. Borghi, H. Bräuninger, G. Cantatore, J. M. Carmona, S. A. Cetin, J. I. Collar, T. Dafni, M. Davenport, C. Eleftheriadis, N. Elias, C. Ezer, G. Fanourakis, P. Friedrich, J. Galán, J. A. García, A. Gardikiotis, J. G. Garza, E. N. Gazis, T. Geralis, I. Giomataris , et al. (47 additional authors not shown)

    Abstract: The status of the solar axion search with the CERN Axion Solar Telescope (CAST) will be presented. Recent results obtained by the use of $^3$He as a buffer gas has allowed us to extend our sensitivity to higher axion masses than our previous measurements with $^4$He. With about 1 h of data taking at each of 252 different pressure settings we have scanned the axion mass range 0.39 eV… ▽ More

    Submitted 30 October, 2012; v1 submitted 27 September, 2012; originally announced September 2012.

    Comments: 4 pages, 2 pages, to appear in the proceedings of the 24th Rencontres de Blois V2 A few affiliations were not corrected in previous version V3 Author added

  41. arXiv:1208.5690  [pdf, other

    physics.ins-det astro-ph.SR hep-ex

    CAST microbulk micromegas in the Canfranc Underground Laboratory

    Authors: A. Tomás, S. Aune, T. Dafni, G. Fanourakis, E. Ferrer-Ribas, J. Galán, J. A. García, A. Gardikiotis, T. Geralis, I. Giomataris, H. Gómez, J. G. Garza, D. C. Herrera, F. J. Iguaz, I. G. Irastorza, G. Luzón, T. Papaevangelou, A. Rodríguez, J. Ruz, L. Seguí, T. Vafeiadis, S. C. Yildiz

    Abstract: During the last taking data campaigns of the CAST experiment, the micromegas detectors have achieved background levels of $\approx 5 \times 10^{-6}$keV$^{-1}$cm$^{-2}$s$^{-1}$ between 2 and 9 keV. This performance has been possible thanks to the introduction of the microbulk technology, the implementation of a shielding and the development of discrimination algorithms. It has motivated new studies… ▽ More

    Submitted 28 August, 2012; originally announced August 2012.

    Comments: 6 pages, 8 figures. To appear in the proceedings of the 2nd International Conference on Technology and Instrumentation for Particle Physics (TIPP 2011)

    Journal ref: Proceedings of the 2nd International Conference on Technology and Instrumentation in Particle Physics (TIPP 2011) Volume 37, 2012, Pages 478-482

  42. arXiv:1206.6199  [pdf, other

    physics.ins-det hep-ex

    Design and characterization of the SiPM tracking system of NEXT-DEMO, a demonstrator prototype of the NEXT-100 experiment

    Authors: NEXT Collaboration, V. Álvarez, M. Ball, F. I. G. M. Borges, S. Cárcel, J. M. Carmona, J. Castel, J. M. Catalá, S. Cebrián, A. Cervera, D. Chan, C. A. N. Conde, T. Dafni, T. H. V. T. Dias, J. Díaz, M. Egorov, R. Esteve, P. Evtoukhovitch, L. M. P. Fernandes, P. Ferrario, A. L. Ferreira, E. Ferrer-Ribas, E. D. C. Freitas, A. N. C. Garcia, V. M. Gehman , et al. (64 additional authors not shown)

    Abstract: NEXT-100 experiment aims at searching the neutrinoless double-beta decay of the Xe-136 isotope using a TPC filled with a 100 kg of high-pressure gaseous xenon, with 90% isotopic enrichment. The experiment will take place at the Laboratorio Subterráneo de Canfranc (LSC), Spain. NEXT-100 uses electroluminescence (EL) technology for energy measurement with a resolution better than 1% FWHM. The gaseou… ▽ More

    Submitted 22 February, 2013; v1 submitted 27 June, 2012; originally announced June 2012.

    Comments: Submitted to JINST

  43. arXiv:1202.1074  [pdf, other

    physics.ins-det hep-ex

    Performances of Anode-resistive Micromegas for HL-LHC

    Authors: J. Manjarres, T. Alexopoulos, D. Attie, M. Boyer, J. Derre, G. Fanourakis, E. Ferrer-Ribas, J. Galan, E. Gazis, T. Geralis, A. Giganon, I. Giomataris, S. Herlant, F. Jeanneau, Ph. Schune, M. Titov, G. Tsipolitis

    Abstract: Micromegas technology is a promising candidate to replace Atlas forward muon chambers -tracking and trigger- for future HL-LHC upgrade of the experiment. The increase on background and pile-up event probability requires detector performances which are currently under studies in intensive RD activities. We studied performances of four different resistive Micromegas detectors with different read-o… ▽ More

    Submitted 6 February, 2012; originally announced February 2012.

    Comments: "Presented at the 2011 Hadron Collider Physics symposium (HCP-2011), Paris, France, November 14-18 2011, 3 pages, 6 figures. "

  44. arXiv:1202.0721  [pdf, other

    physics.ins-det hep-ex

    NEXT-100 Technical Design Report (TDR). Executive Summary

    Authors: NEXT Collaboration, V. Álvarez, F. I. G. M. Borges, S. Cárcel, J. M. Carmona, J. Castel, J. M. Catalá, S. Cebrián, A. Cervera, D. Chan, C. A. N. Conde, T. Dafni, T. H. V. T. Dias, J. Díaz, M. Egorov, R. Esteve, P. Evtoukhovitch, L. M. P. Fernandes, P. Ferrario, A. L. Ferreira, E. Ferrer-Ribas, E. D. C. Freitas, V. M. Gehman, A. Gil, I. Giomataris , et al. (62 additional authors not shown)

    Abstract: In this Technical Design Report (TDR) we describe the NEXT-100 detector that will search for neutrinoless double beta decay (bbonu) in Xe-136 at the Laboratorio Subterraneo de Canfranc (LSC), in Spain. The document formalizes the design presented in our Conceptual Design Report (CDR): an electroluminescence time projection chamber, with separate readout planes for calorimetry and tracking, located… ▽ More

    Submitted 16 April, 2012; v1 submitted 3 February, 2012; originally announced February 2012.

    Comments: 32 pages, 22 figures, 5 tables

    Journal ref: JINST 7 (2012) T06001

  45. arXiv:1201.3849  [pdf, ps, other

    hep-ex

    The International Axion Observatory (IAXO)

    Authors: I. G. Irastorza, F. T. Avignone, G. Cantatore, S. Caspi, J. M. Carmona, T. Dafni, M. Davenport, A. Dudarev, G. Fanourakis, E. Ferrer-Ribas, J. Galan, J. A. Garcia, T. Geralis, I. Giomataris, S. Gninenko, H. Gomez, D. H. H. Hoffmann, F. J. Iguaz, K. Jakovcic, M. Krcmar, B. Lakic, G. Luzon, A. Lindner, M. Pivovaroff, T. Papaevangelou , et al. (14 additional authors not shown)

    Abstract: The International Axion Observatory (IAXO) is a new generation axion helioscope aiming at a sensitivity to the axion-photon coupling of a few 10$^{12}$ GeV$^{-1}$, i.e. 1 - 1.5 orders of magnitude beyond the one currently achieved by CAST. The project relies on improvements in magnetic field volume together with extensive use of x-ray focusing optics and low background detectors, innovations alrea… ▽ More

    Submitted 18 January, 2012; originally announced January 2012.

    Comments: 4 pages, 2 figures. To appear in the proceedings of the 7th Patras Workshop on Axions, WIMPs and WISPs, Mykonos, Greece, 2011

  46. arXiv:1201.3012  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Characterization of microbulk detectors in argon- and neon-based mixtures

    Authors: F. J. Iguaz, E. Ferrer-Ribas, A. Giganon, I. Giomataris

    Abstract: A recent Micromegas manufacturing technique, so called Microbulk, has been developed, improving the uniformity and stability of this kind of detectors. Excellent energy resolutions have been obtained, reaching values as low as 11% FWHM at 5.9 keV in Ar+5%iC4H10. This detector has other advantages like its flexible structure, low material budget and high radio-purity. Two microbulk detectors with g… ▽ More

    Submitted 14 January, 2012; originally announced January 2012.

    Comments: Submitted to the Journal of Instrumentation

  47. arXiv:1201.2018  [pdf, other

    physics.ins-det hep-ex

    SiPMs coated with TPB : coating protocol and characterization for NEXT

    Authors: V. Álvarez, J. Agramunt, M. Ball, M. Batallé, J. Bayarri, F. I. G. Borges, H. Bolink, H. Brine, S. Cárcel, J. M. Carmona, J. Castel, J. M. Catalá, S. Cebrián, A. Cervera, D. Chan, C. A. N. Conde, T. Dafni, T. H. V. T. Dias, J. Díaz, R. Esteve, P. Evtoukhovitch, J. Ferrando, L. M. P. Fernandes, P. Ferrario, A. L. Ferreira , et al. (69 additional authors not shown)

    Abstract: Silicon photomultipliers (SiPM) are the photon detectors chosen for the tracking readout in NEXT, a neutrinoless ββ decay experiment which uses a high pressure gaseous xenon time projection chamber (TPC). The reconstruction of event track and topology in this gaseous detector is a key handle for background rejection. Among the commercially available sensors that can be used for tracking, SiPMs off… ▽ More

    Submitted 10 January, 2012; originally announced January 2012.

    Comments: Submitted to the Journal of Instrumentation on december 26th 2011

    Journal ref: JINST 7 (2012) P02010

  48. arXiv:1201.1843  [pdf, other

    physics.ins-det hep-ex

    Performances and ageing study of resistive-anodes Micromegas detectors for HL-LHC environment

    Authors: F. Jeanneau, T. Alexopoulos, D. Attié, M. Boyer, J. Derré, G. Fanourakis, E. Ferrer-Ribas, J. Galán, E. Gazis, T. Geralis, A. Giganon, I. Giomataris, S. Herlant, J. Manjarrés, E. Ntomari, Ph. Schune, M. Titov, G. Tsipolitis

    Abstract: With the tenfold luminosity increase envisaged at the HL-LHC, the background (photons, neutrons, ...) and the event pile-up probability are expected to increase in proportion in the different experiments, especially in the forward regions like, for instance, the muons chambers of the ATLAS detector. Detectors based on the Micromegas principle should be good alternatives for the detector upgrade in… ▽ More

    Submitted 9 January, 2012; originally announced January 2012.

  49. arXiv:1110.2643  [pdf, other

    physics.ins-det hep-ex

    The discrimination capabilities of Micromegas detectors at low energy

    Authors: F. J. Iguaz, T. Dafni, E. Ferrer-Ribas, J. Galán, J. A. García, A. Gardikiotis, I. Giomataris, I. G. Irastorza, J. P. Mols, T. Papaevangelou, A. Rodríguez, A. Tomás, T. Vafeiadis, C. Yildiz

    Abstract: The latest generation of Micromegas detectors show a good energy resolution, spatial resolution and low threshold, which make them idoneous in low energy applications. Two micromegas detectors have been built for dark matter experiments: CAST, which uses a dipole magnet to convert axion into detectable x-ray photons, and MIMAC, which aims to reconstruct the tracks of low energy nuclear recoils in… ▽ More

    Submitted 12 October, 2011; originally announced October 2011.

    Comments: To be published in the proceedings of the TIPP2011 conference (Physics Procedia)

  50. arXiv:1110.2641  [pdf, other

    physics.ins-det

    New developments in Micromegas Microbulk detectors

    Authors: F. J. Iguaz, S. Andriamonje, F. Belloni, E. Berthoumieux, M. Calviani, T. Dafni, R. De Oliveira, E. Ferrer-Ribas, J. Galán, J. A. García, I. Giomataris, C. Guerrero, F. Gunsing, D. C. Herrera, I. G. Irastorza, T. Papaevangelou, A. Rodríguez, A. Tomás

    Abstract: A new Micromegas manufacturing technique, based on kapton etching technology, has been recently developed, improving the uniformity and stability of this kind of readouts. Excellent energy resolutions have been obtained, reaching 11% FWHM for the 5.9 keV photon peak of 55Fe source and 1.8% FWHM for the 5.5 MeV alpha peak of the 241Am source. The new detector has other advantages like its flexible… ▽ More

    Submitted 12 October, 2011; originally announced October 2011.

    Comments: To be published in the Proceedings of the TIPP2011 conference (Physics Procedia)