Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content

Showing 1–50 of 56 results for author: Guillaudin, O

.
  1. arXiv:2312.12842  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Directional detection of keV proton and carbon recoils with MIMAC

    Authors: C. Beaufort, O. Guillaudin, D. Santos, N. Sauzet, E. Mobio, R. Babut, C. Tao

    Abstract: Directional detection is the dedicated strategy to demonstrate that DM-like signals measured by direct detectors are indeed produced by DM particles from the galactic halo. The experimental challenge of measuring the direction of DM-induced nuclear recoils with (sub-)millimeter tracks has limited, so far, the maximal directional reach to DM masses around $100~\rm{GeV}$. In this paper, we expose th… ▽ More

    Submitted 27 March, 2024; v1 submitted 20 December, 2023; originally announced December 2023.

    Comments: 25 pages, 11 figures

  2. arXiv:2310.16505  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Directional detection of meV dark photons with Dandelion

    Authors: C. Beaufort, M. Bastero-Gil, A. Catalano, D-S. Erfani-Harami, O. Guillaudin, D. Santos, S. Savorgnano, F. Vezzu

    Abstract: This paper presents Dandelion, a new dish antenna experiment searching for dark photons (DPs) with masses around the meV that will start acquiring data by the end of 2023. A spherical mirror acts as a conversion surface between DPs and standard photons that converge to a matrix of 418 Kinetic Inductance Detectors cooled down to 150 mK. A tilt of the mirror at 1 Hz moves the expected signal over th… ▽ More

    Submitted 25 October, 2023; originally announced October 2023.

    Comments: 17 pages, 7 figures

  3. arXiv:2301.05183  [pdf, other

    hep-ex hep-ph

    Exploring light dark matter with the DarkSPHERE spherical proportional counter electroformed underground at the Boulby Underground Laboratory

    Authors: L. Balogh, C. Beaufort, M. Chapellier, E. C. Corcoran, J. -M. Coquillat, A. Dastgheibi-Fard, Y. Deng, D. Durnford, C. Garrah, G. Gerbier, I. Giomataris, G. Giroux, P. Gorel, M. Gros, P. Gros, O. Guillaudin, E. W. Hoppe, I. Katsioulas, F. Kelly, P. Knights, P. Lautridou, I. Manthos, R. D. Martin, J. Matthews, J. -F. Muraz , et al. (15 additional authors not shown)

    Abstract: We present the conceptual design and the physics potential of DarkSPHERE, a proposed 3 m in diameter spherical proportional counter electroformed underground at the Boulby Underground Laboratory. This effort builds on the R&D performed and experience acquired by the NEWS-G Collaboration. DarkSPHERE is primarily designed to search for nuclear recoils from light dark matter in the 0.05--10 GeV mass… ▽ More

    Submitted 14 December, 2023; v1 submitted 12 January, 2023; originally announced January 2023.

    Comments: 19 pages, 14 figures

  4. The NEWS-G detector at SNOLAB

    Authors: L. Balogh, C. Beaufort, A. Brossard, J. F. Caron, M. Chapellier, J. M. Coquillat, E. C. Corcoran, S. Crawford, A. Dastgheibi-Fard, Y. Deng, K. Dering, D. Durnford, C. Garrah, G. Gerbier, I. Giomataris, G. Giroux, P. Gorel, M. Gros, P. Gros, O. Guillaudin, E. W. Hoppe, I. Katsioulas, F. Kelly, P. Knights, L. Kwon , et al. (16 additional authors not shown)

    Abstract: The New Experiments With Spheres-Gas (NEWS-G) collaboration intends to achieve $\mathrm{sub-GeV/c^{2}}$ Weakly Interacting Massive Particles (WIMPs) detection using Spherical Proportional Counters (SPCs). SPCs are gaseous detectors relying on ionization with a single ionization electron energy threshold. The latest generation of SPC for direct dark matter searches has been installed at SNOLAB in C… ▽ More

    Submitted 4 January, 2023; v1 submitted 30 May, 2022; originally announced May 2022.

    Comments: 18 pages, 9 figures, 5 tables, to be published

  5. arXiv:2203.07361  [pdf, other

    hep-ph astro-ph.HE hep-ex

    Coherent elastic neutrino-nucleus scattering: Terrestrial and astrophysical applications

    Authors: M. Abdullah, H. Abele, D. Akimov, G. Angloher, D. Aristizabal-Sierra, C. Augier, A. B. Balantekin, L. Balogh, P. S. Barbeau, L. Baudis, A. L. Baxter, C. Beaufort, G. Beaulieu, V. Belov, A. Bento, L. Berge, I. A. Bernardi, J. Billard, A. Bolozdynya, A. Bonhomme, G. Bres, J-. L. Bret, A. Broniatowski, A. Brossard, C. Buck , et al. (250 additional authors not shown)

    Abstract: Coherent elastic neutrino-nucleus scattering (CE$ν$NS) is a process in which neutrinos scatter on a nucleus which acts as a single particle. Though the total cross section is large by neutrino standards, CE$ν$NS has long proven difficult to detect, since the deposited energy into the nucleus is $\sim$ keV. In 2017, the COHERENT collaboration announced the detection of CE$ν$NS using a stopped-pion… ▽ More

    Submitted 14 March, 2022; originally announced March 2022.

    Comments: contribution to Snowmasss 2021. Contact authors: P. S. Barbeau, R. Strauss, L. E. Strigari

  6. arXiv:2202.05097  [pdf, other

    astro-ph.IM physics.ins-det

    EXCESS workshop: Descriptions of rising low-energy spectra

    Authors: P. Adari, A. Aguilar-Arevalo, D. Amidei, G. Angloher, E. Armengaud, C. Augier, L. Balogh, S. Banik, D. Baxter, C. Beaufort, G. Beaulieu, V. Belov, Y. Ben Gal, G. Benato, A. Benoît, A. Bento, L. Bergé, A. Bertolini, R. Bhattacharyya, J. Billard, I. M. Bloch, A. Botti, R. Breier, G. Bres, J-. L. Bret , et al. (281 additional authors not shown)

    Abstract: Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was… ▽ More

    Submitted 4 March, 2022; v1 submitted 10 February, 2022; originally announced February 2022.

    Comments: 44 pages, 20 figures; Editors: A. Fuss, M. Kaznacheeva, F. Reindl, F. Wagner; updated copyright statements and funding information

    Journal ref: SciPost Phys. Proc. 9, 001 (2022)

  7. arXiv:2201.09566  [pdf, other

    physics.ins-det hep-ex

    Measurements of the ionization efficiency of protons in methane

    Authors: NEWS-G Collaboration, :, L. Balogh, C. Beaufort, A. Brossard, J. -F. Caron, M. Chapellier, J. -M. Coquillat, E. C. Corcoran, S. Crawford, A. Dastgheibi-Fard, Y. Deng, K. Dering, D. Durnford, C. Garrah, G. Gerbier, I. Giomataris, G. Giroux, P. Gorel, M. Gros, P. Gros, O. Guillaudin, E. W. Hoppe, I. Katsioulas, F. Kelly , et al. (19 additional authors not shown)

    Abstract: The amount of energy released by a nuclear recoil ionizing the atoms of the active volume of detection appears "quenched" compared to an electron of the same kinetic energy. This different behavior in ionization between electrons and nuclei is described by the Ionization Quenching Factor (IQF) and it plays a crucial role in direct dark matter searches. For low kinetic energies (below… ▽ More

    Submitted 25 June, 2022; v1 submitted 24 January, 2022; originally announced January 2022.

    Comments: 12 pages, 9 figures

  8. arXiv:2112.12469  [pdf, other

    physics.ins-det hep-ex

    Directionality and head-tail recognition in the keV-range with the MIMAC detector by deconvolution of the ionic signal

    Authors: Cyprien Beaufort, Olivier Guillaudin, Jean-François Muraz, Nadine Sauzet, Daniel Santos, Richard Babut

    Abstract: Directional detection is the only strategy for the unambiguous identification of galactic Dark Matter (DM) even in the presence of an irreducible background such as beyond the neutrino floor. This approach requires measuring the direction of a DM-induced nuclear recoil in the keV-range. To probe such low energies, directional detectors must operate at high gain where 3D track reconstruction can be… ▽ More

    Submitted 28 July, 2022; v1 submitted 23 December, 2021; originally announced December 2021.

    Comments: 30 pages, 16 figures

  9. arXiv:2109.03562  [pdf, other

    hep-ex astro-ph.IM astro-ph.SR

    Solar Kaluza-Klein axion search with NEWS-G

    Authors: NEWS-G collaboration, :, Q. Arnaud, L. Balogh, C. Beaufort, A. Brossard, J. -F. Caron, M. Chapellier, J. -M. Coquillat, E. C. Corcoran, S. Crawford, A. Dastgheibi-Fard, Y. Deng, K. Dering, D. Durnford, C. Garrah, G. Gerbier, I. Giomataris, G. Giroux, P. Gorel, M. Gros, P. Gros, O. Guillaudin, E. W. Hoppe, I. Katsioulas , et al. (18 additional authors not shown)

    Abstract: Kaluza-Klein (KK) axions appear in theories with extra dimensions as higher mass, significantly shorter lifetime, excitations of the Peccei-Quinn axion. When produced in the Sun, they would remain gravitationally trapped in the solar system, and their decay to a pair of photons could provide an explanation of the solar corona heating problem. A low-density detector would discriminate such a signal… ▽ More

    Submitted 9 January, 2022; v1 submitted 8 September, 2021; originally announced September 2021.

    Comments: 19 pages, 11 figures. Updated with additional details requested during review for publication in PRD and mild relaxation of final constraint

    Journal ref: Phys. Rev. D 105, 012002 (2022)

  10. arXiv:2109.01055  [pdf, other

    physics.ins-det hep-ex

    Quenching factor measurements of neon nuclei in neon gas

    Authors: L. Balogh, C. Beaufort, A. Brossard, J. -F. Caron, M. Chapellier, J. -M. Coquillat, E. C. Corcoran, S. Crawford, A. Dastgheibi Fard, Y. Deng, K. Dering, D. Durnford, C. Garrah, G. Gerbier, I. Giomataris, G. Giroux, P. Gorel, M. Gros, P. Gros, O. Guillaudin, E. W. Hoppe, I. Katsioulas, F. Kelly, P. Knights, L. Kwon , et al. (25 additional authors not shown)

    Abstract: The NEWS-G collaboration uses Spherical Proportional Counters (SPCs) to search for weakly interacting massive particles (WIMPs). In this paper, we report the first measurements of the nuclear quenching factor in neon gas at \SI{2}{bar} using an SPC deployed in a neutron beam at the TUNL facility. The energy-dependence of the nuclear quenching factor is modelled using a simple power law: $α$E… ▽ More

    Submitted 3 December, 2021; v1 submitted 2 September, 2021; originally announced September 2021.

    Journal ref: Phys. Rev. D. Vol. 105, No. 5, 052004 (2022)

  11. arXiv:2008.03153  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Copper electroplating for background suppression in the NEWS-G experiment

    Authors: NEWS-G Collaboration, :, L. Balogh, C. Beaufort, A. Brossard, R. Bunker, J. -F. Caron, M. Chapellier, J. -M. Coquillat, E. C. Corcoran, S. Crawford, A. Dastgheibi Fard, Y. Deng, K. Dering, D. Durnford, G. Gerbier, I. Giomataris, G. Giroux, P. Gorel, M. Gros, P. Gros, O. Guillaudin, E. W. Hoppe, I. Katsioulas, F. Kelly , et al. (26 additional authors not shown)

    Abstract: New Experiments with Spheres-Gas (NEWS-G) is a dark matter direct detection experiment that will operate at SNOLAB (Canada). Similar to other rare-event searches, the materials used in the detector construction are subject to stringent radiopurity requirements. The detector features a 140-cm diameter proportional counter comprising two hemispheres made from commercially sourced 99.99% pure copper.… ▽ More

    Submitted 13 December, 2020; v1 submitted 7 August, 2020; originally announced August 2020.

    Comments: 11 pages, 11 figures, 3 tables

    Journal ref: Nucl.Instrum.Meth.A 988 (2021) 164844

  12. arXiv:2003.11812  [pdf, other

    physics.ins-det hep-ex

    Dark Matter Directionality Detection performance of the Micromegas-based $μ$TPC-MIMAC detector

    Authors: Y. Tao, C. Beaufort, I. Moric, C. Tao, D. Santos, N. Sauzet, C. Couturier, O. Guillaudin, J. F. Muraz, F. Naraghi, N. Zhou, J. Busto

    Abstract: Directional Dark Matter Detection (DDMD) can open a new signature for Weakly Massive Interacting Particles (WIMPs) Dark Matter. The directional signature provides in addition, an unique way to overcome the neutron and neutrino backgrounds. In order to get the directional signature, the DDM detectors should be sensitive to low nuclear energy recoils in the keV range and have an angular resolution b… ▽ More

    Submitted 27 July, 2020; v1 submitted 26 March, 2020; originally announced March 2020.

    Comments: 19 pages, 12 figures

  13. arXiv:1906.03878  [pdf

    physics.ins-det nucl-ex

    Fast neutron spectroscopy from 1 MeV up to 15 MeV with Mimac-FastN, a mobile and directional fast neutron spectrometer

    Authors: Nadine Sauzet, Daniel Santos, Olivier Guillaudin, Germain Bosson, Joël Bouvier, Thierry Descombes, Marc Marton, Jean-François Muraz

    Abstract: In the frame of direct dark matter search, the fast neutrons producing elastic collisions are the ultimate background. The MIMAC (MIcro-tpc MAtrix Chambers) project has developed a directional detector providing the directional signature to discriminate them based on 3D nuclear tracks reconstruction. The MIMAC team of the LPSC has adapted one MIMAC chamber as a portable fast neutron spectrometer,… ▽ More

    Submitted 12 March, 2020; v1 submitted 10 June, 2019; originally announced June 2019.

    Comments: 34 pages, 32 figures

  14. arXiv:1903.02159  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Track length measurement of $^{19}$F$^+$ ions with the MIMAC Dark Matter directional detector prototype

    Authors: Y. Tao, C. Beaufort, I. Moric, C. Tao, D. Santos, N. Sauzet, C. Couturier, O. Guillaudin, J. F. Muraz, F. Naraghi, N. Zhou, J. Busto

    Abstract: Weakly Interacting Massive Particles (WIMPs) are one of the most preferred candidate for Dark Matter. WIMPs should interact with the nuclei of detectors. If a robust signal is eventually observed in direct detection experiments, the best signature to confirm its Galactic origin would be the nuclear recoil track direction. The MIMAC collaboration has developed a low pressure gas detector providing… ▽ More

    Submitted 26 March, 2020; v1 submitted 5 March, 2019; originally announced March 2019.

    Comments: 17 pages, 10 figures

    Journal ref: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Volume 985, 1 January 2021, 164569

  15. arXiv:1902.08960  [pdf, other

    physics.ins-det astro-ph.IM

    Precision laser-based measurements of the single electron response of SPCs for the NEWS-G light dark matter search experiment

    Authors: NEWS-G Collaboration, :, Q. Arnaud, J. -P. Bard, A. Brossard, M. Chapellier, M. Clark, S. Crawford, E. C. Corcoran, A. Dastgheibi-Fard, K. Dering, P. Di Stefano, D. Durnford, G. Gerbier, I. Giomataris, G. Giroux, P. Gorel, M. Gros, P. Gros, O. Guillaudin, E. W. Hoppe, A. Kamaha, I. Katsioulas, D. G. Kelly, P. Knights , et al. (15 additional authors not shown)

    Abstract: Spherical Proportional Counters (SPCs) are a novel gaseous detector technology employed by the NEWS-G low-mass dark matter search experiment for their high sensitivity to single electrons from ionization. In this paper, we report on the first characterization of the single electron response of SPCs with unprecedented precision, using a UV-laser calibration system. The experimental approach and ana… ▽ More

    Submitted 24 February, 2019; originally announced February 2019.

    Comments: 12 pages, 8 figures, submitted to Phys. Rev. D

    Journal ref: Phys. Rev. D 99, 102003 (2019)

  16. arXiv:1711.07301  [pdf, other

    astro-ph.IM physics.ins-det

    Cathode signal in a TPC directional detector: implementation and validation measuring the drift velocity

    Authors: C. Couturier, Q. Riffard, N. Sauzet, O. Guillaudin, F. Naraghi, D. Santos

    Abstract: Low-pressure gaseous TPCs are well suited detectors to correlate the directions of nuclear recoils to the galactic Dark Matter (DM) halo. Indeed, in addition to providing a measure of the energy deposition due to the elastic scattering of a DM particle on a nucleus in the target gas, they allow for the reconstruction of the track of the recoiling nucleus. In order to exclude the background events… ▽ More

    Submitted 20 November, 2017; originally announced November 2017.

    Comments: 8 pages, 3 figures. Submitted for publication to JINST

  17. arXiv:1706.04934  [pdf, other

    astro-ph.IM astro-ph.CO physics.ins-det

    First results from the NEWS-G direct dark matter search experiment at the LSM

    Authors: NEWS-G Collaboration, :, Q. Arnaud, D. Asner, J. -P. Bard, A. Brossard, B. Cai, M. Chapellier, M. Clark, E. C. Corcoran, T. Dandl, A. Dastgheibi-Fard, K. Dering, P. Di Stefano, D. Durnford, G. Gerbier, I. Giomataris, P. Gorel, M. Gros, O. Guillaudin, E. W. Hoppe, A. Kamaha, I. Katsioulas, D. G. Kelly, R. D. Martin , et al. (12 additional authors not shown)

    Abstract: New Experiments With Spheres-Gas (NEWS-G) is a direct dark matter detection experiment using Spherical Proportional Counters (SPCs) with light noble gases to search for low-mass Weakly Interacting Massive Particles (WIMPs). We report the results from the first physics run taken at the Laboratoire Souterrain de Modane (LSM) with SEDINE, a 60 cm diameter prototype SPC operated with a mixture of… ▽ More

    Submitted 7 September, 2017; v1 submitted 15 June, 2017; originally announced June 2017.

    Comments: 18 pages, 10 figures, acknowledgments section updated

  18. arXiv:1610.02396  [pdf, other

    physics.ins-det astro-ph.CO astro-ph.IM hep-ex

    Readout technologies for directional WIMP Dark Matter detection

    Authors: J. B. R. Battat, I. G. Irastorza, A. Aleksandrov, M. Ali Guler, T. Asada, E. Baracchini, J. Billard, G. Bosson, O. Bourrion, J. Bouvier, A. Buonaura, K. Burdge, S. Cebrian, P. Colas, L. Consiglio, T. Dafni, N. D'Ambrosio, C. Deaconu, G. De Lellis, T. Descombes, A. Di Crescenzo, N. Di Marco, G. Druitt, R. Eggleston, E. Ferrer-Ribas , et al. (68 additional authors not shown)

    Abstract: The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial… ▽ More

    Submitted 6 October, 2016; originally announced October 2016.

    Comments: 58 pages, 26 figures, accepted by Physics Reports

    Journal ref: Physics Reports 662 (2016) pp. 1-46

  19. arXiv:1607.08765  [pdf, other

    astro-ph.IM astro-ph.CO physics.ins-det

    Directional detection of Dark Matter with the MIcro-tpc MAtrix of Chambers

    Authors: C. Couturier, O. Guillaudin, F. Naraghi, Q. Riffard, D. Santos, N. Sauzet, P. Colas, E. Ferrer Ribas, I. Giomataris, J. Busto, D. Fouchez, C. Tao, N. Zhou

    Abstract: Particles weakly interacting with ordinary matter, with an associated mass of the order of an atomic nucleus (WIMPs), are plausible candidates for Dark Matter. The direct detection of an elastic collision of a target nuclei induced by one of these WIMPs has to be discriminated from the signal produced by the neutrons, which leaves the same signal in a detector. The MIMAC (MIcro-tpc MAtrix of Chamb… ▽ More

    Submitted 29 July, 2016; originally announced July 2016.

    Comments: 4 pages, 1 figure. Proceedings of the 51st Rencontres de Moriond: Cosmology, March 19-26, 2016, La Thuile, Italy

  20. arXiv:1602.01738  [pdf, other

    astro-ph.IM physics.ins-det

    MIMAC low energy electron-recoil discrimination measured with fast neutrons

    Authors: Q. Riffard, D. Santos, O. Guillaudin, G. Bosson, O. Bourrion, J. Bouvier, T. Descombes, J. -F. Muraz, L. Lebreton, D. Maire, P. Colas, I. Giomataris, J. Busto, D. Fouchez, J. Brunner, C. Tao

    Abstract: MIMAC (MIcro-TPC MAtrix of Chambers) is a directional WIMP Dark Matter detector project. Direct dark matter experiments need a high level of electron/recoil discrimination to search for nuclear recoils produced by WIMP-nucleus elastic scattering. In this paper, we proposed an original method for electron event rejection based on a multivariate analysis applied to experimental data acquired using m… ▽ More

    Submitted 4 July, 2016; v1 submitted 4 February, 2016; originally announced February 2016.

    Comments: 27 pages, 20 figures

  21. arXiv:1504.05865  [pdf, other

    astro-ph.IM nucl-ex physics.ins-det

    First detection of tracks of radon progeny recoils by MIMAC

    Authors: Q. Riffard, D. Santos, G. Bosson, O. Bourrion, T. Descombes, C. Fourel, O. Guillaudin, J. -F. Muraz, P. Colas, E. Ferrer-Ribas, I. Giomataris, J. Busto, D. Fouchez, C. Tao, L. Lebreton, D. Maire

    Abstract: The MIMAC experiment is a $μ$-TPC matrix project for directional dark matter search. Directional detection is a strategy based on the measurement of the WIMP flux anisotropy due to the solar system motion with respect to the dark matter halo. The main purpose of MIMAC project is the measurement of the energy and the direction of nuclear recoils in 3D produced by elastic scattering of WIMPs. Since… ▽ More

    Submitted 20 June, 2017; v1 submitted 22 April, 2015; originally announced April 2015.

    Comments: 11 pages, 12 figures, submitted to PRD

  22. Impact of particles on the Planck HFI detectors: Ground-based measurements and physical interpretation

    Authors: A. Catalano, P. Ade, Y. Atik, A. Benoit, E. Bréele, J. J. Bock, P. Camus, M. Chabot, M. Charra, B. P. Crill, N. Coron, A. Coulais, F. -X. Désert, L. Fauvet, Y. Giraud-Héraud, O. Guillaudin, W. Holmes, W. C. Jones, J. -M. Lamarre, J. Macías-Pérez, M. Martinez, A. Miniussi, A. Monfardini, F. Pajot, G. Patanchon , et al. (9 additional authors not shown)

    Abstract: The Planck High Frequency Instrument (HFI) surveyed the sky continuously from August 2009 to January 2012. Its noise and sensitivity performance were excellent, but the rate of cosmic ray impacts on the HFI detectors was unexpectedly high. Furthermore, collisions of cosmic rays with the focal plane produced transient signals in the data (glitches) with a wide range of characteristics. A study of c… ▽ More

    Submitted 2 September, 2014; v1 submitted 26 March, 2014; originally announced March 2014.

    Comments: 11 pages, 13 figures

    Journal ref: A&A 569, A88 (2014)

  23. Characterization and Physical Explanation of Energetic Particles on Planck HFI Instrument

    Authors: A. Catalano, P. Ade, Y. Atik, A. Benoit, E. Bréele, J. J. Bock, P. Camus, M. Charra, B. P. Crill, N. Coron, A. Coulais, F. -X. Désert, L. Fauvet, Y. Giraud-Héraud, O. Guillaudin, W. Holmes, W. C. Jones, J. -M. Lamarre, J. Macías-Pérez, M. Martinez, A. Miniussi, A. Monfardini, F. Pajot, G. Patanchon, A. Pelissier , et al. (8 additional authors not shown)

    Abstract: The Planck High Frequency Instrument (HFI) has been surveying the sky continuously from the second Lagrangian point (L2) between August 2009 and January 2012. It operates with 52 high impedance bolometers cooled at 100mK in a range of frequency between 100 GHz and 1THz with unprecedented sensivity, but strong coupling with cosmic radiation. At L2, the particle flux is about 5 $cm^{-2} s^{-1}$ and… ▽ More

    Submitted 22 March, 2014; originally announced March 2014.

    Comments: LTD-15 Conference

  24. arXiv:1401.1009  [pdf, ps, other

    astro-ph.IM physics.ins-det

    Measurement of the electron drift velocity for directional dark matter detectors

    Authors: F. Mayet, J. Billard, G. Bosson, O. Bourrion, O. Guillaudin, J. Lamblin, J. P. Richer, Q. Riffard, D. Santos, F. J. Iguaz, L. Lebreton, D. Maire

    Abstract: Three-dimensional track reconstruction is a key issue for directional Dark Matter detection. It requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by sim… ▽ More

    Submitted 6 January, 2014; originally announced January 2014.

    Comments: Proceedings of the 4th international conference on Directional Detection of Dark Matter (CYGNUS 2013), 10-12 June 2013, Toyama, Japan

    Report number: in2p3-00845411

    Journal ref: J. Phys. Conf. Ser. 469 (2013) 012006

  25. arXiv:1311.0616  [pdf, other

    physics.ins-det astro-ph.CO

    MIMAC: MIcro-tpc MAtrix of Chambers for dark matter directional detection

    Authors: D. Santos, G. Bosson, J. L. Bouly, O. Bourrion, Ch. Fourel, O. Guillaudin, J. Lamblin, F. Mayet, J. F. Muraz, J. P. Richer, Q. Riffard, L. Lebreton, D. Maire, J. Busto, J. Brunner, D. Fouchez

    Abstract: Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from neutrons, the ultimate background for dark matter direct detection. This strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last ye… ▽ More

    Submitted 4 November, 2013; originally announced November 2013.

    Comments: Proceedings of the 4th International Conference on Directional Dark Matter Detection CYGNUS2013, held in Toyoma (Japan), June 2013

  26. arXiv:1310.6837  [pdf

    physics.ins-det nucl-ex

    Measurement of a 127 keV Neutron Field with a micro-TPC Spectrometer

    Authors: D. Maire, J. Billard, G. Bosson, O. Bourrion, O. Guillaudin, J. Lamblin, L. Lebreton, F. Mayet, J. Médard, J. F. Muraz, M. Petit, J. P. Richer, Q. Riffard, D. Santos

    Abstract: In order to measure the energy of neutron fields, with energy ranging from 8 keV to 1 MeV, a new primary standard is being developed at the IRSN (Institute for Radioprotection and Nuclear Safety). This project, micro-TPC (Micro Time Projection Chamber), carried out in collaboration with the LPSC (Laboratoire de Physique Subatomique et de Cosmologie), is based on the nuclear recoil detector princip… ▽ More

    Submitted 7 January, 2014; v1 submitted 25 October, 2013; originally announced October 2013.

    Comments: 7 pages. Submitted in IEEE TNS/ Special Issue ANIMMA 2013

  27. arXiv:1310.5923  [pdf

    physics.ins-det nucl-ex

    Development of a microtpc detector as a standard instrument for low energy neutron field characterization

    Authors: D. Maire, J. Billard, G. Bosson, O. Bourrion, O. Guillaudin, J. Lamblin, L. Lebreton, F. Mayet, J. Médard, J-F. Muraz, J-P. Richer, Q. Riffard, D. Santos

    Abstract: In order to measure energy and fluence of neutron fields, with energy ranging from 8 keV to 1 MeV, a new primary standard is being developed at the IRSN (Institute for Radioprotection and Nuclear Safety). This project, micro-TPC (Micro Time Projection Chamber), carried out in collaboration with the LPSC, is based on the nucleus recoil detector principle. The measurement strategy requires track rec… ▽ More

    Submitted 22 October, 2013; originally announced October 2013.

    Comments: Neudos12 symposium proceeding. 4 pages

    Journal ref: Radiat. Prot. Dosimetry 161 (2014) 245

  28. arXiv:1306.4173  [pdf, other

    astro-ph.IM astro-ph.CO physics.ins-det

    Dark Matter directional detection with MIMAC

    Authors: Q. Riffard, J. Billard, G. Bosson, O. Bourrion, O. Guillaudin, J. Lamblin, F. Mayet, J. -F. Muraz, J. -P. Richer, D. Santos, L. Lebreton, D. Maire, J. Busto, J. Brunner, D. Fouchez

    Abstract: Directional detection is a promising direct Dark Matter (DM) search strategy. The angular distribution of the nuclear recoil tracks from WIMP events should present an anisotropy in galactic coordinates. This strategy requires both a measurement of the recoil energy with a threshold of about 5 keV and 3D recoil tracks down to few millimeters. The MIMAC project, based on a \textmu-TPC matrix, with… ▽ More

    Submitted 18 June, 2013; originally announced June 2013.

    Comments: Proceedings of the 48th Rencontres de Moriond: Very High Energy Phenomena in the Universe, 9-16 March 2013, La Thuile, Italy

    Report number: LPSC13144

  29. arXiv:1305.2360  [pdf, ps, other

    astro-ph.IM physics.ins-det

    In situ measurement of the electron drift velocity for upcoming directional Dark Matter detectors

    Authors: J. Billard, F. Mayet, G. Bosson, O. Bourrion, O. Guillaudin, J. Lamblin, J. P. Richer, Q. Riffard, D. Santos, F. J. Iguaz, L. Lebreton, D. Maire

    Abstract: Three-dimensional track reconstruction is a key issue for directional Dark Matter detection and it requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by… ▽ More

    Submitted 28 January, 2014; v1 submitted 10 May, 2013; originally announced May 2013.

    Comments: 19 pages, 14 figures. Minor corrections, matches published version in JINST

    Journal ref: JINST 9 (2014) P01013

  30. arXiv:1304.2255  [pdf, other

    physics.ins-det astro-ph.CO

    MIMAC: A micro-tpc matrix for dark matter directional detection

    Authors: D. Santos, J. Billard, G. Bosson, J. L. Bouly, O. Bourrion, C. Fourel, O. Guillaudin, J. Lamblin, J. F. Muraz, F. Mayet, J. P. Richer, Q. Riffard, E. Ferrer, I. Giomataris, F. J. Iguaz, L. Lebreton, D. Maire

    Abstract: The dark matter directional detection opens a new field in cosmology bringing the possibility to build a map of nuclear recoils that would be able to explore the galactic dark matter halo giving access to a particle characterization of such matter and the shape of the halo. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last years an original prototype detector based o… ▽ More

    Submitted 8 April, 2013; originally announced April 2013.

    Comments: Proceedings of the 6th Symposium on Large TPCs for low energy rare event detection, Paris, December 2012

  31. A μ-TPC detector for the characterization of low energy neutron fields

    Authors: C. Golabek, J. Billard, A. Allaoua, G. Bosson, O. Bourrion, C. Grignon, O. Guillaudin, L. Lebreton, F. Mayet, M. Petit, J. -P. Richer, D. Santos

    Abstract: The AMANDE facility produces monoenergetic neutron fields from 2 keV to 20 MeV for metrological purposes. To be considered as a reference facility, fluence and energy distributions of neutron fields have to be determined by primary measurement standards. For this purpose, a micro Time Projection Chamber is being developed to be dedicated to measure neutron fields with energy ranging from 8 keV up… ▽ More

    Submitted 12 March, 2012; originally announced March 2012.

    Journal ref: Nucl. Instrum. Meth. A678 (2012) 33-38

  32. arXiv:1111.1566  [pdf, ps, other

    astro-ph.IM astro-ph.CO

    MIMAC: A micro-tpc matrix project for directional detection of dark matter

    Authors: D. Santos, J. Billard, G. Bosson, J. L. Bouly, O. Bourrion, Ch. Fourel, O. Guillaudin, F. Mayet, J. P. Richer, A. Delbart, E. Ferrer, I. Giomataris, F. J. Iguaz, J. P. Mols, C. Golabek, L. Lebreton

    Abstract: Directional detection of non-baryonic DarkMatter is a promising search strategy for discriminating WIMP events from background ones. This strategy requires both a measurement of the recoil energy down to a few keV and 3D reconstruction of tracks down to a few mm. The MIMAC project, based on a micro-TPC matrix, filled with CF4 and CHF3 is being developed. The first results of a chamber prototype of… ▽ More

    Submitted 7 November, 2011; originally announced November 2011.

    Comments: Proceedings of the 3rd International Conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois- France- June 2011

  33. Development and validation of a 64 channel front end ASIC for 3D directional detection for MIMAC

    Authors: J. P. Richer, O. Bourrion, G. Bosson, O. Guillaudin, F. Mayet, D. Santos

    Abstract: A front end ASIC has been designed to equip the μTPC prototype developed for the MIMAC project, which requires 3D reconstruction of low energy particle tracks in order to perform directional detection of galactic Dark Matter. Each ASIC is able to monitor 64 strips of pixels and provides the "Time Over Threshold" information for each of those. These 64 digital informations, sampled at a rate of 50… ▽ More

    Submitted 10 November, 2011; v1 submitted 20 October, 2011; originally announced October 2011.

    Comments: proceedings of TWEPP-11, Vienna, Austria, 26-30 September 2011

    Journal ref: 2011 JINST 6 C11016

  34. Data acquisition electronics and reconstruction software for real time 3D track reconstruction within the MIMAC project

    Authors: O. Bourrion, G. Bosson, C. Grignon, J. L. Bouly, J. P. Richer, O. Guillaudin, F. Mayet, J. Billard, D. Santos

    Abstract: Directional detection of non-baryonic Dark Matter requires 3D reconstruction of low energy nuclear recoils tracks. A gaseous micro-TPC matrix, filled with either 3He, CF4 or C4H10 has been developed within the MIMAC project. A dedicated acquisition electronics and a real time track reconstruction software have been developed to monitor a 512 channel prototype. This autotriggered electronic uses em… ▽ More

    Submitted 2 November, 2011; v1 submitted 19 October, 2011; originally announced October 2011.

    Comments: Proceedings of TWEPP-11, Vienna, Austria, 26-30 September 2011

    Journal ref: 2011 JINST 6 C11003

  35. arXiv:1110.2042  [pdf, ps, other

    physics.ins-det

    Quenching factor measurement in low pressure gas detector for directional dark matter search

    Authors: O. Guillaudin, J. Billard, G. Bosson, O. Bourrion, T. Lamy, F. Mayet, D. Santos, P. Sortais

    Abstract: There is considerable experimental effort dedicated to the directional detection of particle dark matter. Gaseous mu-TPC detectors present the privileged features of being able to reconstruct the track and the energy of the recoil nucleus following the interaction. A precise measurement of the recoil energy is a key point for the directional search strategy. Quenching has to be taken into account,… ▽ More

    Submitted 10 October, 2011; originally announced October 2011.

    Comments: Proceedings of the 3rd International conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois, France, 8-10 June 2011

    Journal ref: EAS Publications Series 53 (2012) 119-127

  36. Dedicated front-end and readout electronics developments for real time 3D directional detection of dark matter with MIMAC

    Authors: O. Bourrion, G. Bosson, C. Grignon, J. P. Richer, O. Guillaudin, F. Mayet, J. Billard, D. Santos

    Abstract: A complete dedicated electronics, from front-end to back-end, was developed to instrument a MIMAC prototype. A front end ASIC able to monitor 64 strips of pixels and to provide their individual "Time Over Threshold" information has been designed. An associated acquisition electronics and a real time track reconstruction software have been developed to monitor a 512 channel prototype. This auto-tri… ▽ More

    Submitted 19 September, 2011; v1 submitted 9 September, 2011; originally announced September 2011.

    Comments: Proceedings of the 3rd International conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois, France, 8-10 June 2011

    Journal ref: EAS Publication Series 53 (2012) pp 129 - 136

  37. arXiv:1109.1675  [pdf, other

    physics.ins-det astro-ph.IM

    Micromegas detector developments for MIMAC

    Authors: E. Ferrer-Ribas, D. Attié, D. Calvet, P. Colas, F. Druillole, Y. Giomataris, F. J. Iguaz, J. P. Mols, J. Pancin, T. Papaevangelou, J. Billard, G. Bosson, J. L. Bouly, O. Bourrion, Ch. Fourel, C. Grignon, O. Guillaudin, F. Mayet, J. P. Richer, D. Santos, C. Golabek, L. Lebreton

    Abstract: The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC. The recent Micromegas efforts towards building a large size detector will be described, in particular the characterization measurements of a prototype detector of 10 $\times$ 10 cm$^2$ with a 2 dimensional readout plane. Track reconstruction with alpha particles will be shown.

    Submitted 12 September, 2011; v1 submitted 8 September, 2011; originally announced September 2011.

    Comments: 8 pages, 7 figures Proceedings of the 3rd International conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois, France, 8-10 June 2011; corrections on author affiliations

  38. Micromegas detector developments for Dark Matter directional detection with MIMAC

    Authors: F. J. Iguaz, D. Attié, D. Calvet, P. Colas, F. Druillole, E. Ferrer-Ribas, I. Giomataris, J. P. Mols, J. Pancin, T. Papaevangelou, J. Billard, G. Bosson, J. L. Bouly, O. Bourrion, Ch. Fourel, C. Grignon, O. Guillaudin, F. Mayet, J. P. Richer, D. Santos, C. Golabek, L. Lebreton

    Abstract: The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC using a high precision Micromegas readout plane. We will describe in detail the recent developments done with bulk Micromegas detectors as well as the characterisation measurements performed in an Argon(95%)-Isobutane(5%) mixture. Track measurements with alpha particles will be shown.

    Submitted 10 May, 2011; originally announced May 2011.

    Comments: 12 pages, 12 figures

    Journal ref: JINST 6:P07002,2011

  39. MIMAC : A micro-tpc matrix for directional detection of dark matter

    Authors: D. Santos, J. Billard, G. Bosson, J. L. Bouly, O. Bourrion, Ch. Fourel, C. Grignon, O. Guillaudin, F. Mayet, J. P. Richer, A. Delbart, E. Ferrer, I. Giomataris, F. J. Iguaz, J. P. Mols, C. Golabek, L. Lebreton

    Abstract: Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with CF4 and CHF3. T… ▽ More

    Submitted 16 February, 2011; originally announced February 2011.

    Comments: 6 pages, Proc. of the fifth international symposium on large TPCs for low energy rare event detection, Paris, France, Dec. 2010. To appear in Journal of Physics

    Report number: LPSC10223

    Journal ref: J.Phys.Conf.Ser. 309 (2011) 012014

  40. arXiv:1012.1166  [pdf, ps, other

    astro-ph.IM astro-ph.CO

    MIMAC : A micro-tpc matrix for directional detection of dark matter

    Authors: D. Santos, J. Billard, G. Bosson, O. Bourrion, C. Grignon, O. Guillaudin, F. Mayet, J. P. Richer, E. Ferrer, I. Giomataris, F. J. Iguaz, J. P. Mols, A. Allaoua, C. Golabek, L. Lebreton

    Abstract: Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with 3He, CF4 and/or… ▽ More

    Submitted 6 December, 2010; originally announced December 2010.

    Comments: Proceedings of Identification of Dark Matter 2010-IDM2010 conference

  41. arXiv:1008.4712  [pdf, ps, other

    astro-ph.IM

    Directional detection of non-baryonic dark matter with MIMAC

    Authors: C. Grignon, J. Billard, G. Bosson, O. Bourrion, O. Guillaudin, F. Mayet, J. P. Richer, D. Santos, E. Ferrer, I. Giomataris, J. P. Mols

    Abstract: Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating genuine WIMP events from background ones. However, carrying out such a strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed: it is based on a gaseous micro-TPC matrix,… ▽ More

    Submitted 17 September, 2010; v1 submitted 27 August, 2010; originally announced August 2010.

    Comments: 4 pages, proc. of the 22nd Rencontres de Blois: Particle Physics and Cosmology, 15-20 July 2010, Blois, France

  42. Data acquisition electronics and reconstruction software for directional detection of Dark Matter with MIMAC

    Authors: O. Bourrion, G. Bosson, C. Grignon, J. L. Bouly, J. P. Richer, O. Guillaudin, F. Mayet, D. Santos

    Abstract: Directional detection of galactic Dark Matter requires 3D reconstruction of low energy nuclear recoils tracks. A dedicated acquisition electronics with auto triggering feature and a real time track reconstruction software have been developed within the framework of the MIMAC project of detector. This auto-triggered acquisition electronic uses embedded processing to reduce data transfer to its usef… ▽ More

    Submitted 7 June, 2010; originally announced June 2010.

    Comments: 17 pages, 12 figures

    Journal ref: Nucl. Instrum. Meth. A662 (2010) 207

  43. arXiv:1004.2365  [pdf, ps, other

    astro-ph.CO

    Directional detection of Dark Matter

    Authors: J. Billard, F. Mayet, J. F. Macias-Perez, D. Santos, C. Grignon, O. Guillaudin

    Abstract: Directional detection of galactic Dark Matter is a promising search strategy for discriminating genuine WIMP events from background ones. However, to take full advantage of this powerful detection method, one need to be able to extract information from an observed recoil map to identify a WIMP signal. We present a comprehensive formalism, using a map-based likelihood method allowing to recover t… ▽ More

    Submitted 14 April, 2010; originally announced April 2010.

    Comments: 4 pages, proc. of the 45th Rencontres De Moriond: Electroweak Interactions And Unified Theories, 6-13 Mar 2010, La Thuile, Italy

    Report number: in2p3-00462516

  44. arXiv:1001.2983  [pdf, ps, other

    astro-ph.CO astro-ph.IM

    Directional detection of galactic Dark Matter

    Authors: F. Mayet, J. Billard, G. Bernard, G. Bosson, O. Bourrion, C. Grignon, O. Guillaudin, C. Koumeir, J. P. Richer, D. Santos, P. Colas, E. Ferer, I. Giomataris, A. Allaoua, L. Lebreton

    Abstract: Directional detection of galactic Dark Matter is a promising search strategy for discriminating geniune WIMP events from background ones. We present technical progress on gaseous detectors as well as recent phenomenological studies, allowing the design and construction of competitive experiments.

    Submitted 18 January, 2010; originally announced January 2010.

    Comments: Proceedings of the 12th Marcel Grossmann Meeting on General Relativity (MG 12), Paris, France, 12-18 Jul 2009

  45. Development of a front end ASIC for Dark Matter directional detection with MIMAC

    Authors: J. P. Richer, G. Bosson, O. Bourrion, C. Grignon, O. Guillaudin, F. Mayet, D. Santos

    Abstract: A front end ASIC (BiCMOS-SiGe 0.35 \mum) has been developed within the framework of the MIMAC detector project, which aims at directional detection of non-baryonic Dark Matter. This search strategy requires 3D reconstruction of low energy (a few keV) tracks with a gaseous \muTPC. The development of this front end ASIC is a key point of the project, allowing the 3D track reconstruction. Each ASIC m… ▽ More

    Submitted 13 April, 2010; v1 submitted 1 December, 2009; originally announced December 2009.

    Comments: 12 pages, 10 figures

    Journal ref: Nucl. Instrum. Meth.A620:470-476, 2010

  46. The case for a directional dark matter detector and the status of current experimental efforts

    Authors: S. Ahlen, N. Afshordi, J. B. R. Battat, J. Billard, N. Bozorgnia, S. Burgos, T. Caldwell, J. M. Carmona, S. Cebrian, P. Colas, T. Dafni, E. Daw, D. Dujmic, A. Dushkin, W. Fedus, E. Ferrer, D. Finkbeiner, P. H. Fisher, J. Forbes, T. Fusayasu, J. Galan, T. Gamble, C. Ghag, I. Giomataris, M. Gold , et al. (87 additional authors not shown)

    Abstract: We present the case for a dark matter detector with directional sensitivity. This document was developed at the 2009 CYGNUS workshop on directional dark matter detection, and contains contributions from theorists and experimental groups in the field. We describe the need for a dark matter detector with directional sensitivity; each directional dark matter experiment presents their project's stat… ▽ More

    Submitted 1 November, 2009; originally announced November 2009.

    Comments: 48 pages, 37 figures, whitepaper on direct dark matter detection with directional sensitivity

    Journal ref: Int.J.Mod.Phys.A25:1-51,2010

  47. arXiv:0909.0654  [pdf, ps, other

    astro-ph.IM astro-ph.CO

    A prototype of a directional detector for non-baryonic dark matter search: MIMAC (Micro-TPC Matrix of Chambers)

    Authors: C. Grignon, G. Bernard, J. Billard, G. Bosson, O. Bourrion, O. Guillaudin, C. Koumeir, F. Mayet, D. Santos, P. Colas, E. Ferrer, I. Giomataris, A. Allaoua, L. Lebreton

    Abstract: We have developed a micro-tpc using a pixelized bulk micromegas coupled to dedicated acquisition electronics as a read-out allowing to reconstruct the three dimensional track of a few keV recoils. The prototype has been tested with the Amande facility at the IRSN-Cadarache providing monochromatic neutrons. The first results concerning discrimination of a few keV electrons and proton recoils are… ▽ More

    Submitted 30 October, 2009; v1 submitted 3 September, 2009; originally announced September 2009.

    Comments: 5 pages, proc. of the 1st International Conference on Micro Pattern Gaseous Detectors MPGD 2009, 12-15 June 2009, Kolympari, Crete, Greece

    Journal ref: JINST 4:P11003,2009

  48. arXiv:0905.4800  [pdf, ps, other

    astro-ph.IM astro-ph.CO

    Dark matter directional detection with MIMAC

    Authors: C. Grignon, J. Billard, G. Bosson, O. Bourrion, O. Guillaudin, C. Koumeir, F. Mayet, D. Santos, P. Colas, E. Ferrer, I. Giomataris

    Abstract: MiMac is a project of micro-TPC matrix of gaseous (He3, CF4) chambers for direct detection of non-baryonic dark matter. Measurement of both track and ionization energy will allow the electron-recoil discrimination, while access to the directionnality of the tracks will open a unique way to distinguish a geniune WIMP signal from any background. First reconstructed tracks of 5.9 keV electrons are… ▽ More

    Submitted 29 May, 2009; originally announced May 2009.

    Comments: 4 pages, proc. of the 44th Rencontres De Moriond: Electroweak Interactions And Unified Theories, 7-14 Mar 2009, La Thuile, Italy

  49. MIMAC : a micro-TPC detector for non-baryonic dark matter search

    Authors: F. Mayet, O. Guillaudin, D. Santos, A. Trichet

    Abstract: The MIMAC project is multi-chamber detector for Dark Matter search, aiming at measuring both track and ionization with a matrix of micromegas micro-TPC filled with He3 and CF4. Recent experimental results on the first measurements of the Helium quenching factor at low energy (1 keV recoil) are presented.

    Submitted 28 May, 2009; originally announced May 2009.

    Comments: 7 pages, Proc of Dark Energy and Dark Matter conference, Lyon : France (2008)

    Journal ref: EAS Publ.Ser.36:263,2009

  50. Micromegas micro-TPC for direct Dark Matter search with MIMAC

    Authors: F. Mayet, O. Guillaudin, C. Grignon, C. Koumeir, D. Santos, P. Colas, I. Giomataris

    Abstract: The MIMAC project is a multi-chamber detector for Dark Matter search, aiming at measuring both track and ionization with a matrix of micromegas micro-TPC filled with He3 and CF4. Recent experimental results on the first measurements of the Helium quenching factor at low energy (1 keV recoil) are presented, together with the first simulation of the track reconstruction. Recontruction of track of… ▽ More

    Submitted 28 May, 2009; originally announced May 2009.

    Comments: 5 pages, Proc. of the fourth international symposium on large TPCs for low energy rare event detection, Paris, France, Dec. 2008. To appear in Journal of Physics

    Journal ref: J.Phys.Conf.Ser.179:012011,2009