Test-Beam and Simulation Studies Towards RPWELL-based DHCAL
Authors:
Dan Shaked-Renous,
Fernando Domingues Amaro,
Purba Bhattacharya,
Amos Breskin,
Maximilien Chefdeville,
Cyril Drancourt,
Theo Geralis,
Yannis Karyotakis,
Luca Moleri,
Andrea Tesi,
Maxim Titov,
Joao Veloso,
Guillaum Vouters,
Shikma Bressler
Abstract:
Digital Hadronic Calorimeters (DHCAL) were suggested for future Colliders as part of the particle-flow concept. Though studied mainly with Resistive Plate Chambers (RPC), studies focusing on Micro-Pattern Gaseous Detector (MPGD)-based sampling elements have shown the potential advantages; they can be operated with environmental friendly gases and reach similar detection efficiency at lower average…
▽ More
Digital Hadronic Calorimeters (DHCAL) were suggested for future Colliders as part of the particle-flow concept. Though studied mainly with Resistive Plate Chambers (RPC), studies focusing on Micro-Pattern Gaseous Detector (MPGD)-based sampling elements have shown the potential advantages; they can be operated with environmental friendly gases and reach similar detection efficiency at lower average pad-multiplicity. We summarize here the experimental test-beam results of a small-size DHCAL prototype, incorporating six Micromegas (MM) and two Resistive-Plate WELL (RPWELL) sampling elements, interlaced with steel-absorber plates. It was investigated with 2-6 GeV pion beam at the CERN/PS beam facility. The data permitted validating a GEANT4 simulation framework of a DHCAL, and evaluating the expected pion energy resolution of a full-scale RPWELL-based calorimeter. The pion energy resolution of $\fracσ{E[GeV]}=\frac{50.8\%}{\sqrt{E[GeV]}} \oplus 10.3\%$ derived expected with the RPWELL concept is competitive to that of glass RPC and MM sampling techniques.
△ Less
Submitted 7 October, 2022; v1 submitted 26 August, 2022;
originally announced August 2022.
-
Study of scintillation light collection, production and propagation in a 4 tonne dual-phase LArTPC
Authors:
B. Aimard,
L. Aizawa,
C. Alt,
J. Asaadi,
M. Auger,
V. Aushev,
D. Autiero,
A. Balaceanu,
G. Balik,
L. Balleyguier,
E. Bechetoille,
D. Belver,
A. M. Blebea-Apostu,
S. Bolognesi,
S. Bordoni,
N. Bourgeois,
B. Bourguille,
J. Bremer,
G. Brown,
G. Brunetti,
L. Brunetti,
D. Caiulo,
M. Calin,
E. Calvo,
M. Campanelli
, et al. (138 additional authors not shown)
Abstract:
The $3 \times 1 \times 1$ m$^3$ demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities. The performances of the photon detection system, composed of five PMTs, are discussed. The collected scintillation and electroluminescence light created by passi…
▽ More
The $3 \times 1 \times 1$ m$^3$ demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities. The performances of the photon detection system, composed of five PMTs, are discussed. The collected scintillation and electroluminescence light created by passing particles has been studied in various detector conditions. In particular, the scintillation light production and propagation processes have been analyzed and compared to simulations, improving the understanding of some liquid argon properties.
△ Less
Submitted 20 December, 2020; v1 submitted 16 October, 2020;
originally announced October 2020.
-
Calibration and performance of the LHCb calorimeters in Run 1 and 2 at the LHC
Authors:
C. Abellán Beteta,
A. Alfonso Albero,
Y. Amhis,
S. Barsuk,
C. Beigbeder-Beau,
I. Belyaev,
R. Bonnefoy,
D. Breton,
O. Callot,
M. Calvo Gomez,
A. Camboni,
H. Chanal,
D. Charlet,
M. Chefdeville,
V. Coco,
E. Cogneras,
A. Comerma-Montells,
S. Coquereau,
O. Deschamps,
F. Domingo Bonal,
C. Drancourt,
O. Duarte,
N. Dumont Dayot,
R. Dzhelyadin,
V. Egorychev
, et al. (62 additional authors not shown)
Abstract:
The calibration and performance of the LHCb Calorimeter system in Run 1 and 2 at the LHC are described. After a brief description of the sub-detectors and of their role in the trigger, the calibration methods used for each part of the system are reviewed. The changes which occurred with the increase of beam energy in Run 2 are explained. The performances of the calorimetry for $γ$ and $π^0$ are de…
▽ More
The calibration and performance of the LHCb Calorimeter system in Run 1 and 2 at the LHC are described. After a brief description of the sub-detectors and of their role in the trigger, the calibration methods used for each part of the system are reviewed. The changes which occurred with the increase of beam energy in Run 2 are explained. The performances of the calorimetry for $γ$ and $π^0$ are detailed. A few results from collisions recorded at $\sqrt {s}$ = 7, 8 and 13 TeV are shown.
△ Less
Submitted 26 August, 2020;
originally announced August 2020.
-
Novel Resistive-Plate WELL sampling element for (S)DHCAL
Authors:
S. Bressler,
P. Bhattacharya,
A. Breskin,
A. E. C. Coimbra,
D. Shaked-Renous,
A. Tesi,
L. Moler,
M. Chefdeville,
G. Vouters,
J. Karyotakis,
C. Drancourt,
M. Titov,
T. Geralis
Abstract:
Digital and Semi-Digital Hadronic Calorimeters (S)DHCAL were suggested for future Colliders as part of the particle-flow concept. Though studied mostly with RPC-based techniques, investigations have shown that MPGD-based sampling elements could outperform. An attractive, industry-produced, robust, particle-tracking detector for large-area coverage, e.g. in (S)DHCAL, could be the novel single-stage…
▽ More
Digital and Semi-Digital Hadronic Calorimeters (S)DHCAL were suggested for future Colliders as part of the particle-flow concept. Though studied mostly with RPC-based techniques, investigations have shown that MPGD-based sampling elements could outperform. An attractive, industry-produced, robust, particle-tracking detector for large-area coverage, e.g. in (S)DHCAL, could be the novel single-stage Resistive Plate WELL (RPWELL). It is a single-sided THGEM coupled to the segmented readout electrode through a sheet of large bulk resistivity. We summarize here the preliminary test-beam results obtained with 6.5 mm thick (incl. electronics) {$48 \times 48\,\mathrm{cm^2}$}~RPWELL detectors. Two configurations are considered: a standalone RPWELL detector studied with 150 GeV muons and high-rate pions beams and RPWELL sampling element investigated within a small-(S)DHCAL prototype consisting of 7 resistive MICROMEGAS sampling elements followed by 5 RPWELL ones. The sampling elements were equipped with a Semi-Digital readout electronics based on the MICROROC chip.
△ Less
Submitted 26 September, 2019; v1 submitted 11 April, 2019;
originally announced April 2019.
-
The Compact Linear Collider (CLIC) - 2018 Summary Report
Authors:
The CLIC,
CLICdp collaborations,
:,
T. K. Charles,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
M. Volpi,
C. Balazs,
K. Afanaciev,
V. Makarenko,
A. Patapenka,
I. Zhuk,
C. Collette,
M. J. Boland,
A. C. Abusleme Hoffman,
M. A. Diaz,
F. Garay,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu,
X. Wang,
J. Zhang
, et al. (671 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the…
▽ More
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.
△ Less
Submitted 6 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.
-
A 4 tonne demonstrator for large-scale dual-phase liquid argon time projection chambers
Authors:
B. Aimard,
Ch. Alt,
J. Asaadi,
M. Auger,
V. Aushev,
D. Autiero,
M. M. Badoi,
A. Balaceanu,
G. Balik,
L. Balleyguier,
E. Bechetoille,
D. Belver,
A. M. Blebea-Apostu,
S. Bolognesi,
S. Bordoni,
N. Bourgeois,
B. Bourguille,
J. Bremer,
G. Brown,
G. Brunetti,
L. Brunetti,
D. Caiulo,
M. Calin,
E. Calvo,
M. Campanelli
, et al. (147 additional authors not shown)
Abstract:
A 10 kilo-tonne dual-phase liquid argon TPC is one of the detector options considered for the Deep Underground Neutrino Experiment (DUNE). The detector technology relies on amplification of the ionisation charge in ultra-pure argon vapour and oers several advantages compared to the traditional single-phase liquid argon TPCs. A 4.2 tonne dual-phase liquid argon TPC prototype, the largest of its kin…
▽ More
A 10 kilo-tonne dual-phase liquid argon TPC is one of the detector options considered for the Deep Underground Neutrino Experiment (DUNE). The detector technology relies on amplification of the ionisation charge in ultra-pure argon vapour and oers several advantages compared to the traditional single-phase liquid argon TPCs. A 4.2 tonne dual-phase liquid argon TPC prototype, the largest of its kind, with an active volume of 3x1x1 $m^3$ has been constructed and operated at CERN. In this paper we describe in detail the experimental setup and detector components as well as report on the operation experience. We also present the first results on the achieved charge amplification, prompt scintillation and electroluminescence detection, and purity of the liquid argon from analyses of a collected sample of cosmic ray muons.
△ Less
Submitted 19 October, 2018; v1 submitted 8 June, 2018;
originally announced June 2018.
-
Updated baseline for a staged Compact Linear Collider
Authors:
The CLIC,
CLICdp collaborations,
:,
M. J. Boland,
U. Felzmann,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
C. Balazs,
T. K. Charles,
K. Afanaciev,
I. Emeliantchik,
A. Ignatenko,
V. Makarenko,
N. Shumeiko,
A. Patapenka,
I. Zhuk,
A. C. Abusleme Hoffman,
M. A. Diaz Gutierrez,
M. Vogel Gonzalez,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu
, et al. (493 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-q…
▽ More
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-quark measurements. Subsequent stages will focus on measurements of rare Higgs processes, as well as searches for new physics processes and precision measurements of new states, e.g. states previously discovered at LHC or at CLIC itself. In the 2012 CLIC Conceptual Design Report, a fully optimised 3 TeV collider was presented, while the proposed lower energy stages were not studied to the same level of detail. This report presents an updated baseline staging scenario for CLIC. The scenario is the result of a comprehensive study addressing the performance, cost and power of the CLIC accelerator complex as a function of centre-of-mass energy and it targets optimal physics output based on the current physics landscape. The optimised staging scenario foresees three main centre-of-mass energy stages at 380 GeV, 1.5 TeV and 3 TeV for a full CLIC programme spanning 22 years. For the first stage, an alternative to the CLIC drive beam scheme is presented in which the main linac power is produced using X-band klystrons.
△ Less
Submitted 27 March, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.
-
Test in a beam of large-area Micromegas chambers for sampling calorimetry
Authors:
C. Adloff,
M. Chefdeville,
A. Dalmaz,
C. Drancourt,
R. Gaglione,
N. Geffroy,
J. Jacquemier,
Y. Karyotakis,
I. Koletsou,
F. Peltier,
J. Samarati,
G. Vouters
Abstract:
Application of Micromegas for sampling calorimetry puts specific constraints on the design and performance of this gaseous detector. In particular, uniform and linear response, low noise and stability against high ionisation density deposits are prerequisites to achieving good energy resolution. A Micromegas-based hadronic calorimeter was proposed for an application at a future linear collider exp…
▽ More
Application of Micromegas for sampling calorimetry puts specific constraints on the design and performance of this gaseous detector. In particular, uniform and linear response, low noise and stability against high ionisation density deposits are prerequisites to achieving good energy resolution. A Micromegas-based hadronic calorimeter was proposed for an application at a future linear collider experiment and three technologically advanced prototypes of 1$\times$1 m$^{2}$ were constructed. Their merits relative to the above-mentioned criteria are discussed on the basis of measurements performed at the CERN SPS test-beam facility.
△ Less
Submitted 3 May, 2014;
originally announced May 2014.
-
The Time Structure of Hadronic Showers in highly granular Calorimeters with Tungsten and Steel Absorbers
Authors:
C. Adloff,
J. -J. Blaising,
M. Chefdeville,
C. Drancourt,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
I. Koletsou,
J. Prast,
G. Vouters J. Repond,
J. Schlereth,
L. Xia E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
G. Eigen,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki J. Apostolakis,
S. Arfaoui,
M. Benoit
, et al. (188 additional authors not shown)
Abstract:
The intrinsic time structure of hadronic showers influences the timing capability and the required integration time of hadronic calorimeters in particle physics experiments, and depends on the active medium and on the absorber of the calorimeter. With the CALICE T3B experiment, a setup of 15 small plastic scintillator tiles read out with Silicon Photomultipliers, the time structure of showers is m…
▽ More
The intrinsic time structure of hadronic showers influences the timing capability and the required integration time of hadronic calorimeters in particle physics experiments, and depends on the active medium and on the absorber of the calorimeter. With the CALICE T3B experiment, a setup of 15 small plastic scintillator tiles read out with Silicon Photomultipliers, the time structure of showers is measured on a statistical basis with high spatial and temporal resolution in sampling calorimeters with tungsten and steel absorbers. The results are compared to GEANT4 (version 9.4 patch 03) simulations with different hadronic physics models. These comparisons demonstrate the importance of using high precision treatment of low-energy neutrons for tungsten absorbers, while an overall good agreement between data and simulations for all considered models is observed for steel.
△ Less
Submitted 21 July, 2014; v1 submitted 25 April, 2014;
originally announced April 2014.
-
Shower development of particles with momenta from 1 to 10 GeV in the CALICE Scintillator-Tungsten HCAL
Authors:
C. Adloff,
J. -J. Blaising,
M. Chefdeville,
C. Drancourt,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
I. Koletsou,
J. Prast,
G. Vouters,
J. Repond,
J. Schlereth,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
G. Eigen,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada
, et al. (194 additional authors not shown)
Abstract:
Lepton colliders are considered as options to complement and to extend the physics programme at the Large Hadron Collider. The Compact Linear Collider (CLIC) is an $e^+e^-$ collider under development aiming at centre-of-mass energies of up to 3 TeV. For experiments at CLIC, a hadron sampling calorimeter with tungsten absorber is proposed. Such a calorimeter provides sufficient depth to contain hig…
▽ More
Lepton colliders are considered as options to complement and to extend the physics programme at the Large Hadron Collider. The Compact Linear Collider (CLIC) is an $e^+e^-$ collider under development aiming at centre-of-mass energies of up to 3 TeV. For experiments at CLIC, a hadron sampling calorimeter with tungsten absorber is proposed. Such a calorimeter provides sufficient depth to contain high-energy showers, while allowing a compact size for the surrounding solenoid.
A fine-grained calorimeter prototype with tungsten absorber plates and scintillator tiles read out by silicon photomultipliers was built and exposed to particle beams at CERN. Results obtained with electrons, pions and protons of momenta up to 10 GeV are presented in terms of energy resolution and shower shape studies. The results are compared with several GEANT4 simulation models in order to assess the reliability of the Monte Carlo predictions relevant for a future experiment at CLIC.
△ Less
Submitted 13 January, 2014; v1 submitted 14 November, 2013;
originally announced November 2013.
-
Validation of GEANT4 Monte Carlo Models with a Highly Granular Scintillator-Steel Hadron Calorimeter
Authors:
C. Adloff,
J. Blaha,
J. -J. Blaising,
C. Drancourt,
A. Espargilière,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
J. Prast,
G. Vouters,
K. Francis,
J. Repond,
J. Schlereth,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
T. Buanes,
G. Eigen,
Y. Mikami,
N. K. Watson
, et al. (148 additional authors not shown)
Abstract:
Calorimeters with a high granularity are a fundamental requirement of the Particle Flow paradigm. This paper focuses on the prototype of a hadron calorimeter with analog readout, consisting of thirty-eight scintillator layers alternating with steel absorber planes. The scintillator plates are finely segmented into tiles individually read out via Silicon Photomultipliers. The presented results are…
▽ More
Calorimeters with a high granularity are a fundamental requirement of the Particle Flow paradigm. This paper focuses on the prototype of a hadron calorimeter with analog readout, consisting of thirty-eight scintillator layers alternating with steel absorber planes. The scintillator plates are finely segmented into tiles individually read out via Silicon Photomultipliers. The presented results are based on data collected with pion beams in the energy range from 8GeV to 100GeV. The fine segmentation of the sensitive layers and the high sampling frequency allow for an excellent reconstruction of the spatial development of hadronic showers. A comparison between data and Monte Carlo simulations is presented, concerning both the longitudinal and lateral development of hadronic showers and the global response of the calorimeter. The performance of several GEANT4 physics lists with respect to these observables is evaluated.
△ Less
Submitted 15 June, 2014; v1 submitted 13 June, 2013;
originally announced June 2013.
-
Track segments in hadronic showers in a highly granular scintillator-steel hadron calorimeter
Authors:
CALICE Collaboration,
C. Adloff,
J. -J. Blaising,
M. Chefdeville,
C. Drancourt,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
I. Koletsou,
J. Prast,
G. Vouters,
K. Francis,
J. Repond,
J. Schlereth,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
G. Eigen,
Y. Mikami,
N. K. Watson
, et al. (184 additional authors not shown)
Abstract:
We investigate the three dimensional substructure of hadronic showers in the CALICE scintillator-steel hadronic calorimeter. The high granularity of the detector is used to find track segments of minimum ionising particles within hadronic showers, providing sensitivity to the spatial structure and the details of secondary particle production in hadronic cascades. The multiplicity, length and angul…
▽ More
We investigate the three dimensional substructure of hadronic showers in the CALICE scintillator-steel hadronic calorimeter. The high granularity of the detector is used to find track segments of minimum ionising particles within hadronic showers, providing sensitivity to the spatial structure and the details of secondary particle production in hadronic cascades. The multiplicity, length and angular distribution of identified track segments are compared to GEANT4 simulations with several different shower models. Track segments also provide the possibility for in-situ calibration of highly granular calorimeters.
△ Less
Submitted 29 July, 2013; v1 submitted 30 May, 2013;
originally announced May 2013.
-
The LHCb Trigger and its Performance in 2011
Authors:
R. Aaij,
J. Albrecht,
F. Alessio,
S. Amato,
E. Aslanides,
I. Belyaev,
M. vanBeuzekom,
E. Bonaccorsi,
R. Bonnefoy,
L. Brarda,
O. Callot,
M. Cattaneo,
H. Chanal,
M. Chebbi,
X. CidVidal,
M. Clemencic,
J. Closier,
V. Coco,
J. Cogan,
O. Deschamps,
H. Dijkstra,
C. Drancourt,
R. Dzhelyadin,
M. Frank,
M. Gandelman
, et al. (58 additional authors not shown)
Abstract:
This paper presents the design of the LHCb trigger and its performance on data taken at the LHC in 2011. A principal goal of LHCb is to perform flavour physics measurements, and the trigger is designed to distinguish charm and beauty decays from the light quark background. Using a combination of lepton identification and measurements of the particles' transverse momenta the trigger selects particl…
▽ More
This paper presents the design of the LHCb trigger and its performance on data taken at the LHC in 2011. A principal goal of LHCb is to perform flavour physics measurements, and the trigger is designed to distinguish charm and beauty decays from the light quark background. Using a combination of lepton identification and measurements of the particles' transverse momenta the trigger selects particles originating from charm and beauty hadrons, which typically fly a finite distance before decaying. The trigger reduces the roughly 11\,MHz of bunch-bunch crossings that contain at least one inelastic $pp$ interaction to 3\,kHz. This reduction takes place in two stages; the first stage is implemented in hardware and the second stage is a software application that runs on a large computer farm. A data-driven method is used to evaluate the performance of the trigger on several charm and beauty decay modes.
△ Less
Submitted 3 April, 2013; v1 submitted 13 November, 2012;
originally announced November 2012.
-
Implications of LHCb measurements and future prospects
Authors:
LHCb collaboration,
A. Bharucha,
I. I. Bigi,
C. Bobeth,
M. Bobrowski,
J. Brod,
A. J. Buras,
C. T. H. Davies,
A. Datta,
C. Delaunay,
S. Descotes-Genon,
J. Ellis,
T. Feldmann,
R. Fleischer,
O. Gedalia,
J. Girrbach,
D. Guadagnoli,
G. Hiller,
Y. Hochberg,
T. Hurth,
G. Isidori,
S. Jaeger,
M. Jung,
A. Kagan,
J. F. Kamenik
, et al. (741 additional authors not shown)
Abstract:
During 2011 the LHCb experiment at CERN collected 1.0 fb-1 of sqrt{s} = 7 TeV pp collisions. Due to the large heavy quark production cross-sections, these data provide unprecedented samples of heavy flavoured hadrons. The first results from LHCb have made a significant impact on the flavour physics landscape and have definitively proved the concept of a dedicated experiment in the forward region a…
▽ More
During 2011 the LHCb experiment at CERN collected 1.0 fb-1 of sqrt{s} = 7 TeV pp collisions. Due to the large heavy quark production cross-sections, these data provide unprecedented samples of heavy flavoured hadrons. The first results from LHCb have made a significant impact on the flavour physics landscape and have definitively proved the concept of a dedicated experiment in the forward region at a hadron collider. This document discusses the implications of these first measurements on classes of extensions to the Standard Model, bearing in mind the interplay with the results of searches for on-shell production of new particles at ATLAS and CMS. The physics potential of an upgrade to the LHCb detector, which would allow an order of magnitude more data to be collected, is emphasised.
△ Less
Submitted 30 April, 2013; v1 submitted 16 August, 2012;
originally announced August 2012.
-
Hadronic energy resolution of a highly granular scintillator-steel hadron calorimeter using software compensation techniques
Authors:
CALICE Collaboration,
C. Adloff,
J. Blaha,
J. -J. Blaising,
C. Drancourt,
A. Espargilière,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
J. Prast,
G. Vouters,
K. Francis,
J. Repond,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
T. Buanes,
G. Eigen,
Y. Mikami,
N. K. Watson
, et al. (142 additional authors not shown)
Abstract:
The energy resolution of a highly granular 1 m3 analogue scintillator-steel hadronic calorimeter is studied using charged pions with energies from 10 GeV to 80 GeV at the CERN SPS. The energy resolution for single hadrons is determined to be approximately 58%/sqrt(E/GeV}. This resolution is improved to approximately 45%/sqrt(E/GeV) with software compensation techniques. These techniques take advan…
▽ More
The energy resolution of a highly granular 1 m3 analogue scintillator-steel hadronic calorimeter is studied using charged pions with energies from 10 GeV to 80 GeV at the CERN SPS. The energy resolution for single hadrons is determined to be approximately 58%/sqrt(E/GeV}. This resolution is improved to approximately 45%/sqrt(E/GeV) with software compensation techniques. These techniques take advantage of the event-by-event information about the substructure of hadronic showers which is provided by the imaging capabilities of the calorimeter. The energy reconstruction is improved either with corrections based on the local energy density or by applying a single correction factor to the event energy sum derived from a global measure of the shower energy density. The application of the compensation algorithms to Geant4 simulations yield resolution improvements comparable to those observed for real data.
△ Less
Submitted 27 September, 2012; v1 submitted 17 July, 2012;
originally announced July 2012.
-
Recent results of Micromegas sDHCAL with a new readout chip
Authors:
C. Adloff,
J. Blaha,
J. -J. Blaising,
M. Chefdeville,
A. Dalmaz,
C. Drancourt,
A. Espargilière,
R. Gaglione,
N. Geffroy,
J. Jacquemier,
Y. Karyotakis,
F. Peltier,
J. Prast,
S. Tsigaridas,
Y. Tsipolitis,
G. Vouters
Abstract:
Calorimetry at future linear colliders could be based on a particle flow approach where granularity is the key to high jet energy resolution. Among different technologies, Micromegas chambers with 1 cm2 pad segmentation are studied for the active medium of a hadronic calorimeter. A chamber of 1 m2 with 9216 channels read out by a low noise front-end ASIC called MICROROC has recently been construct…
▽ More
Calorimetry at future linear colliders could be based on a particle flow approach where granularity is the key to high jet energy resolution. Among different technologies, Micromegas chambers with 1 cm2 pad segmentation are studied for the active medium of a hadronic calorimeter. A chamber of 1 m2 with 9216 channels read out by a low noise front-end ASIC called MICROROC has recently been constructed and tested. Chamber design, ASIC circuitry and preliminary test beam results are reported.
△ Less
Submitted 3 February, 2012;
originally announced February 2012.
-
Micromegas for imaging hadronic calorimetry
Authors:
C. Adloff,
J. Blaha,
S. Cap,
M. Chefdeville,
A. Dalmaz,
C. Drancourt,
A. Espargiliere,
R. Gaglione,
R. Gallet,
N. Geffroy,
J. Jacquemier,
Y. Karyotakis,
F. Peltier,
J. Prast,
G. Vouters
Abstract:
The recent progress in R&D of the Micromegas detectors for hadronic calorimetry including new engineering-technical solutions, electronics development, and accompanying simulation studies with emphasis on the comparison of the physics performance of the analog and digital readout is described. The developed prototypes are with 2 bit digital readout to exploit the Micromegas proportional mode and t…
▽ More
The recent progress in R&D of the Micromegas detectors for hadronic calorimetry including new engineering-technical solutions, electronics development, and accompanying simulation studies with emphasis on the comparison of the physics performance of the analog and digital readout is described. The developed prototypes are with 2 bit digital readout to exploit the Micromegas proportional mode and thus improve the calorimeter linearity. In addition, measurements of detection efficiency, hit multiplicity, and energy shower profiles obtained during the exposure of small size prototypes to radioactive source quanta, cosmic particles and accelerator beams are reported. Eventually, the status of a large scale chamber (1{\times}1 m2) are also presented with prospective towards the construction of a 1 m3 digital calorimeter consisting of 40 such chambers.
△ Less
Submitted 7 February, 2011;
originally announced February 2011.
-
Electromagnetic response of a highly granular hadronic calorimeter
Authors:
C. Adloff,
J. Blaha,
J. -J. Blaising,
C. Drancourt,
A. Espargilière,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
J. Prast,
G. Vouters,
K. Francis,
J. Repond,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
Y. Mikami,
N. K. Watson T. Goto,
G. Mavromanolakis,
M. A. Thomson,
D. R. Ward W. Yan
, et al. (142 additional authors not shown)
Abstract:
The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling calorimeter with steel as absorber and scintillator layers as active material. High granularity is obtained by segmenting the scintillator into small tiles individuall…
▽ More
The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling calorimeter with steel as absorber and scintillator layers as active material. High granularity is obtained by segmenting the scintillator into small tiles individually read out via silicon photo-multipliers (SiPM).
A prototype has been built, consisting of thirty-eight sensitive layers, segmented into about eight thousand channels. In 2007 the prototype was exposed to positrons and hadrons using the CERN SPS beam, covering a wide range of beam energies and incidence angles. The challenge of cell equalization and calibration of such a large number of channels is best validated using electromagnetic processes.
The response of the prototype steel-scintillator calorimeter, including linearity and uniformity, to electrons is investigated and described.
△ Less
Submitted 8 June, 2011; v1 submitted 20 December, 2010;
originally announced December 2010.
-
Status of the Micromegas semi-DHCAL
Authors:
C. Adloff,
J. Blaha,
J. -J. Blaising,
M. Chefdeville,
C. Drancourt,
A. Espargiliere,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
J. Prast,
G. Vouters
Abstract:
The activities towards the fabrication and test of a 1 m3 semi-digital hadronic calorime- ter are reviewed. The prototype sampling planes would consist of 1 m2 Micromegas chambers with 1 cm2 granularity and embedded 2 bits readout suitable for PFA calorime- try at an ILC detector. The design of the 1 m2 chamber is presented first, followed by an overview of the basic performance of small prototype…
▽ More
The activities towards the fabrication and test of a 1 m3 semi-digital hadronic calorime- ter are reviewed. The prototype sampling planes would consist of 1 m2 Micromegas chambers with 1 cm2 granularity and embedded 2 bits readout suitable for PFA calorime- try at an ILC detector. The design of the 1 m2 chamber is presented first, followed by an overview of the basic performance of small prototypes. The basic units composing the 1 m2 chamber are 32 \times 48 cm2 boards with integrated electronics and a micro-mesh. Results of character- ization tests of such boards are shown. Micromegas as a proportional detector is well suited for semi-digital hadronic calorimetry. In order to quantify the gain in perfor- mance when using one or more thresholds, simulation studies are being carried out, some of which will be reported in this contribution.
△ Less
Submitted 19 July, 2010;
originally announced July 2010.
-
MICROMEGAS chambers for hadronic calorimetry at a future linear collider
Authors:
C. Adloff,
D. Attie,
J. Blaha,
S. Cap,
M. Chefdeville,
P. Colas,
A. Dalmaz,
C. Drancourt,
A. Espargiliere,
R. Gaglione,
R. Gallet,
N. Geffroy,
I. Giomataris,
J. Jaquemier,
Y. Karyotakis,
F. Peltier,
J. Prast,
G. Vouters
Abstract:
Prototypes of MICROMEGAS chambers, using bulk technology and analog readout, with 1x1cm2 readout segmentation have been built and tested. Measurements in Ar/iC4H10 (95/5) and Ar/CO2 (80/20) are reported. The dependency of the prototypes gas gain versus pressure, gas temperature and amplification gap thickness variations has been measured with an 55Fe source and a method for temperature and press…
▽ More
Prototypes of MICROMEGAS chambers, using bulk technology and analog readout, with 1x1cm2 readout segmentation have been built and tested. Measurements in Ar/iC4H10 (95/5) and Ar/CO2 (80/20) are reported. The dependency of the prototypes gas gain versus pressure, gas temperature and amplification gap thickness variations has been measured with an 55Fe source and a method for temperature and pressure correction of data is presented. A stack of four chambers has been tested in 200GeV/c and 7GeV/c muon and pion beams respectively. Measurements of response uniformity, detection efficiency and hit multiplicity are reported. A bulk MICROMEGAS prototype with embedded digital readout electronics has been assembled and tested. The chamber layout and first results are presented.
△ Less
Submitted 21 September, 2009; v1 submitted 17 September, 2009;
originally announced September 2009.
-
The STAR Silicon Strip Detector (SSD)
Authors:
L. Arnold,
J. Baudot,
D. Bonnet,
A. Boucham,
S. Bouvier,
J. Castillo,
J. P. Coffin,
C. Drancourt,
B. Erazmus,
L. Gaudichet,
M. Germain,
C. Gojak,
J. Grabski,
G. Guilloux,
M. Guedon,
B. Hippolyte,
M. Janik,
A. Kisiel,
C. Kuhn,
L. Lakehal-Ayat,
F. Lefevre,
C. LeMoal,
P. Leszczynski,
J. R. Lutz,
A. Maliszewski
, et al. (16 additional authors not shown)
Abstract:
The STAR Silicon Strip Detector (SSD) completes the three layers of the Silicon Vertex Tracker (SVT) to make an inner tracking system located inside the Time Projection Chamber (TPC). This additional fourth layer provides two dimensional hit position and energy loss measurements for charged particles, improving the extrapolation of TPC tracks through SVT hits. To match the high multiplicity of c…
▽ More
The STAR Silicon Strip Detector (SSD) completes the three layers of the Silicon Vertex Tracker (SVT) to make an inner tracking system located inside the Time Projection Chamber (TPC). This additional fourth layer provides two dimensional hit position and energy loss measurements for charged particles, improving the extrapolation of TPC tracks through SVT hits. To match the high multiplicity of central Au+Au collisions at RHIC the double sided silicon strip technology was chosen which makes the SSD a half million channels detector. Dedicated electronics have been designed for both readout and control. Also a novel technique of bonding, the Tape Automated Bonding (TAB), was used to fullfill the large number of bounds to be done. All aspects of the SSD are shortly described here and test performances of produced detection modules as well as simulated results on hit reconstruction are given.
△ Less
Submitted 18 November, 2002;
originally announced November 2002.