Test-Beam and Simulation Studies Towards RPWELL-based DHCAL
Authors:
Dan Shaked-Renous,
Fernando Domingues Amaro,
Purba Bhattacharya,
Amos Breskin,
Maximilien Chefdeville,
Cyril Drancourt,
Theo Geralis,
Yannis Karyotakis,
Luca Moleri,
Andrea Tesi,
Maxim Titov,
Joao Veloso,
Guillaum Vouters,
Shikma Bressler
Abstract:
Digital Hadronic Calorimeters (DHCAL) were suggested for future Colliders as part of the particle-flow concept. Though studied mainly with Resistive Plate Chambers (RPC), studies focusing on Micro-Pattern Gaseous Detector (MPGD)-based sampling elements have shown the potential advantages; they can be operated with environmental friendly gases and reach similar detection efficiency at lower average…
▽ More
Digital Hadronic Calorimeters (DHCAL) were suggested for future Colliders as part of the particle-flow concept. Though studied mainly with Resistive Plate Chambers (RPC), studies focusing on Micro-Pattern Gaseous Detector (MPGD)-based sampling elements have shown the potential advantages; they can be operated with environmental friendly gases and reach similar detection efficiency at lower average pad-multiplicity. We summarize here the experimental test-beam results of a small-size DHCAL prototype, incorporating six Micromegas (MM) and two Resistive-Plate WELL (RPWELL) sampling elements, interlaced with steel-absorber plates. It was investigated with 2-6 GeV pion beam at the CERN/PS beam facility. The data permitted validating a GEANT4 simulation framework of a DHCAL, and evaluating the expected pion energy resolution of a full-scale RPWELL-based calorimeter. The pion energy resolution of $\fracσ{E[GeV]}=\frac{50.8\%}{\sqrt{E[GeV]}} \oplus 10.3\%$ derived expected with the RPWELL concept is competitive to that of glass RPC and MM sampling techniques.
△ Less
Submitted 7 October, 2022; v1 submitted 26 August, 2022;
originally announced August 2022.
-
Single Electron Spectra in RPWELL-based detectors
Authors:
Purba Bhattacharya,
Andrea Tesi,
Dan Shaked-Renous,
Luca Moleri,
Amos Breskin,
Shikma Bressler
Abstract:
Single-electron avalanche distributions in gaseous multipliers affect their efficient detection and that of single UV-photons. In this work, we investigated the shape of single-photo-electron spectra in single- and double-stage Resistive Plate WELL (RPWELL) detector configurations, operated in $\mathrm{Ne/CH_{4}}$ and $\mathrm{Ar/CH_{4}}$. Discharge-free operation was reached over a broad dynamic…
▽ More
Single-electron avalanche distributions in gaseous multipliers affect their efficient detection and that of single UV-photons. In this work, we investigated the shape of single-photo-electron spectra in single- and double-stage Resistive Plate WELL (RPWELL) detector configurations, operated in $\mathrm{Ne/CH_{4}}$ and $\mathrm{Ar/CH_{4}}$. Discharge-free operation was reached over a broad dynamic range, with charge gains of \numrange[range-phrase = -]{e4}{e6}. Compared to the usual exponential ones, the observed Polya-like charge spectra pave the way towards higher single-electrons detection efficiencies. The latter were evaluated here, using experimental data combined with numerical simulations. The effects of the gas mixtures, electric field configuration and detector geometry on the Polya spectra and their related "$θ$" parameter are presented.
△ Less
Submitted 21 June, 2021; v1 submitted 5 January, 2021;
originally announced January 2021.
-
Novel Resistive-Plate WELL sampling element for (S)DHCAL
Authors:
S. Bressler,
P. Bhattacharya,
A. Breskin,
A. E. C. Coimbra,
D. Shaked-Renous,
A. Tesi,
L. Moler,
M. Chefdeville,
G. Vouters,
J. Karyotakis,
C. Drancourt,
M. Titov,
T. Geralis
Abstract:
Digital and Semi-Digital Hadronic Calorimeters (S)DHCAL were suggested for future Colliders as part of the particle-flow concept. Though studied mostly with RPC-based techniques, investigations have shown that MPGD-based sampling elements could outperform. An attractive, industry-produced, robust, particle-tracking detector for large-area coverage, e.g. in (S)DHCAL, could be the novel single-stage…
▽ More
Digital and Semi-Digital Hadronic Calorimeters (S)DHCAL were suggested for future Colliders as part of the particle-flow concept. Though studied mostly with RPC-based techniques, investigations have shown that MPGD-based sampling elements could outperform. An attractive, industry-produced, robust, particle-tracking detector for large-area coverage, e.g. in (S)DHCAL, could be the novel single-stage Resistive Plate WELL (RPWELL). It is a single-sided THGEM coupled to the segmented readout electrode through a sheet of large bulk resistivity. We summarize here the preliminary test-beam results obtained with 6.5 mm thick (incl. electronics) {$48 \times 48\,\mathrm{cm^2}$}~RPWELL detectors. Two configurations are considered: a standalone RPWELL detector studied with 150 GeV muons and high-rate pions beams and RPWELL sampling element investigated within a small-(S)DHCAL prototype consisting of 7 resistive MICROMEGAS sampling elements followed by 5 RPWELL ones. The sampling elements were equipped with a Semi-Digital readout electronics based on the MICROROC chip.
△ Less
Submitted 26 September, 2019; v1 submitted 11 April, 2019;
originally announced April 2019.
-
The Resistive-Plate WELL with Argon mixtures - a robust gaseous radiation detector
Authors:
L. Moleri,
F. D. Amaro,
L. Arazi,
C. D. R. Azevedo,
E. Oliveri,
M. Pitt,
J. Schaarschmidt,
D. Shaked-Renous,
J. M. F. dos Santos,
J. F. C. A. Veloso,
A. Breskin,
S. Bressler
Abstract:
A thin single-element THGEM-based, Resistive-Plate WELL (RPWELL) detector was operated with 150 GeV/c muon and pion beams in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$); signals were recorded with 1 cm$^2$ square pads and SRS/APV25 electronics. Detection efficiency values greater than 98% were reached in all the gas mixtures, at average pad multiplicity of 1.2. The use of the 10$^9$Ωcm resistiv…
▽ More
A thin single-element THGEM-based, Resistive-Plate WELL (RPWELL) detector was operated with 150 GeV/c muon and pion beams in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$); signals were recorded with 1 cm$^2$ square pads and SRS/APV25 electronics. Detection efficiency values greater than 98% were reached in all the gas mixtures, at average pad multiplicity of 1.2. The use of the 10$^9$Ωcm resistive plate resulted in a completely discharge-free operation also in intense pion beams. The efficiency remained essentially constant at 98-99% up to fluxes of $\sim$10$^4$Hz/cm$^2$, dropping by a few % when approaching 10$^5$ Hz/cm$^2$. These results pave the way towards cost-effective, robust, efficient, large-scale detectors for a variety of applications in future particle, astro-particle and applied fields. A potential target application is digital hadron calorimetry.
△ Less
Submitted 15 March, 2016;
originally announced March 2016.