-
Nuclear Medicine Artificial Intelligence in Action: The Bethesda Report (AI Summit 2024)
Authors:
Arman Rahmim,
Tyler J. Bradshaw,
Guido Davidzon,
Joyita Dutta,
Georges El Fakhri,
Munir Ghesani,
Nicolas A. Karakatsanis,
Quanzheng Li,
Chi Liu,
Emilie Roncali,
Babak Saboury,
Tahir Yusufaly,
Abhinav K. Jha
Abstract:
The 2nd SNMMI Artificial Intelligence (AI) Summit, organized by the SNMMI AI Task Force, took place in Bethesda, MD, on February 29 - March 1, 2024. Bringing together various community members and stakeholders, and following up on a prior successful 2022 AI Summit, the summit theme was: AI in Action. Six key topics included (i) an overview of prior and ongoing efforts by the AI task force, (ii) em…
▽ More
The 2nd SNMMI Artificial Intelligence (AI) Summit, organized by the SNMMI AI Task Force, took place in Bethesda, MD, on February 29 - March 1, 2024. Bringing together various community members and stakeholders, and following up on a prior successful 2022 AI Summit, the summit theme was: AI in Action. Six key topics included (i) an overview of prior and ongoing efforts by the AI task force, (ii) emerging needs and tools for computational nuclear oncology, (iii) new frontiers in large language and generative models, (iv) defining the value proposition for the use of AI in nuclear medicine, (v) open science including efforts for data and model repositories, and (vi) issues of reimbursement and funding. The primary efforts, findings, challenges, and next steps are summarized in this manuscript.
△ Less
Submitted 3 June, 2024;
originally announced June 2024.
-
Knowledge-grounded Adaptation Strategy for Vision-language Models: Building Unique Case-set for Screening Mammograms for Residents Training
Authors:
Aisha Urooj Khan,
John Garrett,
Tyler Bradshaw,
Lonie Salkowski,
Jiwoong Jason Jeong,
Amara Tariq,
Imon Banerjee
Abstract:
A visual-language model (VLM) pre-trained on natural images and text pairs poses a significant barrier when applied to medical contexts due to domain shift. Yet, adapting or fine-tuning these VLMs for medical use presents considerable hurdles, including domain misalignment, limited access to extensive datasets, and high-class imbalances. Hence, there is a pressing need for strategies to effectivel…
▽ More
A visual-language model (VLM) pre-trained on natural images and text pairs poses a significant barrier when applied to medical contexts due to domain shift. Yet, adapting or fine-tuning these VLMs for medical use presents considerable hurdles, including domain misalignment, limited access to extensive datasets, and high-class imbalances. Hence, there is a pressing need for strategies to effectively adapt these VLMs to the medical domain, as such adaptations would prove immensely valuable in healthcare applications. In this study, we propose a framework designed to adeptly tailor VLMs to the medical domain, employing selective sampling and hard-negative mining techniques for enhanced performance in retrieval tasks. We validate the efficacy of our proposed approach by implementing it across two distinct VLMs: the in-domain VLM (MedCLIP) and out-of-domain VLMs (ALBEF). We assess the performance of these models both in their original off-the-shelf state and after undergoing our proposed training strategies, using two extensive datasets containing mammograms and their corresponding reports. Our evaluation spans zero-shot, few-shot, and supervised scenarios. Through our approach, we observe a notable enhancement in Recall@K performance for the image-text retrieval task.
△ Less
Submitted 30 May, 2024;
originally announced May 2024.
-
Automatic Quantification of Serial PET/CT Images for Pediatric Hodgkin Lymphoma Patients Using a Longitudinally-Aware Segmentation Network
Authors:
Xin Tie,
Muheon Shin,
Changhee Lee,
Scott B. Perlman,
Zachary Huemann,
Amy J. Weisman,
Sharon M. Castellino,
Kara M. Kelly,
Kathleen M. McCarten,
Adina L. Alazraki,
Junjie Hu,
Steve Y. Cho,
Tyler J. Bradshaw
Abstract:
$\textbf{Purpose}$: Automatic quantification of longitudinal changes in PET scans for lymphoma patients has proven challenging, as residual disease in interim-therapy scans is often subtle and difficult to detect. Our goal was to develop a longitudinally-aware segmentation network (LAS-Net) that can quantify serial PET/CT images for pediatric Hodgkin lymphoma patients. $\textbf{Materials and Metho…
▽ More
$\textbf{Purpose}$: Automatic quantification of longitudinal changes in PET scans for lymphoma patients has proven challenging, as residual disease in interim-therapy scans is often subtle and difficult to detect. Our goal was to develop a longitudinally-aware segmentation network (LAS-Net) that can quantify serial PET/CT images for pediatric Hodgkin lymphoma patients. $\textbf{Materials and Methods}$: This retrospective study included baseline (PET1) and interim (PET2) PET/CT images from 297 patients enrolled in two Children's Oncology Group clinical trials (AHOD1331 and AHOD0831). LAS-Net incorporates longitudinal cross-attention, allowing relevant features from PET1 to inform the analysis of PET2. Model performance was evaluated using Dice coefficients for PET1 and detection F1 scores for PET2. Additionally, we extracted and compared quantitative PET metrics, including metabolic tumor volume (MTV) and total lesion glycolysis (TLG) in PET1, as well as qPET and $Δ$SUVmax in PET2, against physician measurements. We quantified their agreement using Spearman's $ρ$ correlations and employed bootstrap resampling for statistical analysis. $\textbf{Results}$: LAS-Net detected residual lymphoma in PET2 with an F1 score of 0.606 (precision/recall: 0.615/0.600), outperforming all comparator methods (P<0.01). For baseline segmentation, LAS-Net achieved a mean Dice score of 0.772. In PET quantification, LAS-Net's measurements of qPET, $Δ$SUVmax, MTV and TLG were strongly correlated with physician measurements, with Spearman's $ρ$ of 0.78, 0.80, 0.93 and 0.96, respectively. The performance remained high, with a slight decrease, in an external testing cohort. $\textbf{Conclusion}$: LAS-Net achieved high performance in quantifying PET metrics across serial scans, highlighting the value of longitudinal awareness in evaluating multi-time-point imaging datasets.
△ Less
Submitted 12 April, 2024;
originally announced April 2024.
-
Anatomy and Physiology of Artificial Intelligence in PET Imaging
Authors:
Tyler J. Bradshaw,
Alan B. McMillan
Abstract:
The influence of artificial intelligence (AI) within the field of nuclear medicine has been rapidly growing. Many researchers and clinicians are seeking to apply AI within PET, and clinicians will soon find themselves engaging with AI-based applications all along the chain of molecular imaging, from image reconstruction to enhanced reporting. This expanding presence of AI in PET imaging will resul…
▽ More
The influence of artificial intelligence (AI) within the field of nuclear medicine has been rapidly growing. Many researchers and clinicians are seeking to apply AI within PET, and clinicians will soon find themselves engaging with AI-based applications all along the chain of molecular imaging, from image reconstruction to enhanced reporting. This expanding presence of AI in PET imaging will result in greater demand for educational resources for those unfamiliar with AI. The objective of this article to is provide an illustrated guide to the core principles of modern AI, with specific focus on aspects that are most likely to be encountered in PET imaging. We describe convolutional neural networks, algorithm training, and explain the components of the commonly used U-Net for segmentation and image synthesis.
△ Less
Submitted 30 November, 2023;
originally announced November 2023.
-
Transverse Emittance Reduction in Muon Beams by Ionization Cooling
Authors:
The MICE Collaboration,
M. Bogomilov,
R. Tsenov,
G. Vankova-Kirilova,
Y. P. Song,
J. Y. Tang,
Z. H. Li,
R. Bertoni,
M. Bonesini,
F. Chignoli,
R. Mazza,
A. de Bari,
D. Orestano,
L. Tortora,
Y. Kuno,
H. Sakamoto,
A. Sato,
S. Ishimoto,
M. Chung,
C. K. Sung,
F. Filthaut,
M. Fedorov,
D. Jokovic,
D. Maletic,
M. Savic
, et al. (112 additional authors not shown)
Abstract:
Accelerated muon beams have been considered for next-generation studies of high-energy lepton-antilepton collisions and neutrino oscillations. However, high-brightness muon beams have not yet been produced. The main challenge for muon acceleration and storage stems from the large phase-space volume occupied by the beam, derived from the muon production mechanism through the decay of pions from pro…
▽ More
Accelerated muon beams have been considered for next-generation studies of high-energy lepton-antilepton collisions and neutrino oscillations. However, high-brightness muon beams have not yet been produced. The main challenge for muon acceleration and storage stems from the large phase-space volume occupied by the beam, derived from the muon production mechanism through the decay of pions from proton collisions. Ionization cooling is the technique proposed to decrease the muon beam phase-space volume. Here we demonstrate a clear signal of ionization cooling through the observation of transverse emittance reduction in beams that traverse lithium hydride or liquid hydrogen absorbers in the Muon Ionization Cooling Experiment (MICE). The measurement is well reproduced by the simulation of the experiment and the theoretical model. The results shown here represent a substantial advance towards the realization of muon-based facilities that could operate at the energy and intensity frontiers.
△ Less
Submitted 13 October, 2023; v1 submitted 9 October, 2023;
originally announced October 2023.
-
Automatic Personalized Impression Generation for PET Reports Using Large Language Models
Authors:
Xin Tie,
Muheon Shin,
Ali Pirasteh,
Nevein Ibrahim,
Zachary Huemann,
Sharon M. Castellino,
Kara M. Kelly,
John Garrett,
Junjie Hu,
Steve Y. Cho,
Tyler J. Bradshaw
Abstract:
In this study, we aimed to determine if fine-tuned large language models (LLMs) can generate accurate, personalized impressions for whole-body PET reports. Twelve language models were trained on a corpus of PET reports using the teacher-forcing algorithm, with the report findings as input and the clinical impressions as reference. An extra input token encodes the reading physician's identity, allo…
▽ More
In this study, we aimed to determine if fine-tuned large language models (LLMs) can generate accurate, personalized impressions for whole-body PET reports. Twelve language models were trained on a corpus of PET reports using the teacher-forcing algorithm, with the report findings as input and the clinical impressions as reference. An extra input token encodes the reading physician's identity, allowing models to learn physician-specific reporting styles. Our corpus comprised 37,370 retrospective PET reports collected from our institution between 2010 and 2022. To identify the best LLM, 30 evaluation metrics were benchmarked against quality scores from two nuclear medicine (NM) physicians, with the most aligned metrics selecting the model for expert evaluation. In a subset of data, model-generated impressions and original clinical impressions were assessed by three NM physicians according to 6 quality dimensions (3-point scale) and an overall utility score (5-point scale). Each physician reviewed 12 of their own reports and 12 reports from other physicians. Bootstrap resampling was used for statistical analysis. Of all evaluation metrics, domain-adapted BARTScore and PEGASUSScore showed the highest Spearman's rank correlations (0.568 and 0.563) with physician preferences. Based on these metrics, the fine-tuned PEGASUS model was selected as the top LLM. When physicians reviewed PEGASUS-generated impressions in their own style, 89% were considered clinically acceptable, with a mean utility score of 4.08 out of 5. Physicians rated these personalized impressions as comparable in overall utility to the impressions dictated by other physicians (4.03, P=0.41). In conclusion, personalized impressions generated by PEGASUS were clinically useful, highlighting its potential to expedite PET reporting.
△ Less
Submitted 17 October, 2023; v1 submitted 18 September, 2023;
originally announced September 2023.
-
A Relationship Between Spin and Geometry
Authors:
Peter T. J. Bradshaw
Abstract:
In a recent paper, algebraic descriptions for all non-relativistic spins were derived by elementary means directly from the Lie algebra $\specialorthogonalliealgebra{3}$, and a connection between spin and the geometry of Euclidean three-space was drawn. However, the details of this relationship and the extent to which it can be developed by elementary means were not expounded. In this paper, we wi…
▽ More
In a recent paper, algebraic descriptions for all non-relativistic spins were derived by elementary means directly from the Lie algebra $\specialorthogonalliealgebra{3}$, and a connection between spin and the geometry of Euclidean three-space was drawn. However, the details of this relationship and the extent to which it can be developed by elementary means were not expounded. In this paper, we will reveal the geometric content of the spin algebras by realising them within a novel, generalised form of Clifford-like algebra. In so doing, we will demonstrate a natural connection between spin and non-commutative geometry, and discuss the impact of this on the measurement of hypervolumes and on quantum mechanics.
△ Less
Submitted 31 May, 2023;
originally announced June 2023.
-
ConTEXTual Net: A Multimodal Vision-Language Model for Segmentation of Pneumothorax
Authors:
Zachary Huemann,
Xin Tie,
Junjie Hu,
Tyler J. Bradshaw
Abstract:
Radiology narrative reports often describe characteristics of a patient's disease, including its location, size, and shape. Motivated by the recent success of multimodal learning, we hypothesized that this descriptive text could guide medical image analysis algorithms. We proposed a novel vision-language model, ConTEXTual Net, for the task of pneumothorax segmentation on chest radiographs. ConTEXT…
▽ More
Radiology narrative reports often describe characteristics of a patient's disease, including its location, size, and shape. Motivated by the recent success of multimodal learning, we hypothesized that this descriptive text could guide medical image analysis algorithms. We proposed a novel vision-language model, ConTEXTual Net, for the task of pneumothorax segmentation on chest radiographs. ConTEXTual Net utilizes language features extracted from corresponding free-form radiology reports using a pre-trained language model. Cross-attention modules are designed to combine the intermediate output of each vision encoder layer and the text embeddings generated by the language model. ConTEXTual Net was trained on the CANDID-PTX dataset consisting of 3,196 positive cases of pneumothorax with segmentation annotations from 6 different physicians as well as clinical radiology reports. Using cross-validation, ConTEXTual Net achieved a Dice score of 0.716$\pm$0.016, which was similar to the degree of inter-reader variability (0.712$\pm$0.044) computed on a subset of the data. It outperformed both vision-only models (ResNet50 U-Net: 0.677$\pm$0.015 and GLoRIA: 0.686$\pm$0.014) and a competing vision-language model (LAVT: 0.706$\pm$0.009). Ablation studies confirmed that it was the text information that led to the performance gains. Additionally, we show that certain augmentation methods degraded ConTEXTual Net's segmentation performance by breaking the image-text concordance. We also evaluated the effects of using different language models and activation functions in the cross-attention module, highlighting the efficacy of our chosen architectural design.
△ Less
Submitted 15 September, 2023; v1 submitted 2 March, 2023;
originally announced March 2023.
-
Domain-adapted large language models for classifying nuclear medicine reports
Authors:
Zachary Huemann,
Changhee Lee,
Junjie Hu,
Steve Y. Cho,
Tyler Bradshaw
Abstract:
With the growing use of transformer-based language models in medicine, it is unclear how well these models generalize to nuclear medicine which has domain-specific vocabulary and unique reporting styles. In this study, we evaluated the value of domain adaptation in nuclear medicine by adapting language models for the purpose of 5-point Deauville score prediction based on clinical 18F-fluorodeoxygl…
▽ More
With the growing use of transformer-based language models in medicine, it is unclear how well these models generalize to nuclear medicine which has domain-specific vocabulary and unique reporting styles. In this study, we evaluated the value of domain adaptation in nuclear medicine by adapting language models for the purpose of 5-point Deauville score prediction based on clinical 18F-fluorodeoxyglucose (FDG) PET/CT reports. We retrospectively retrieved 4542 text reports and 1664 images for FDG PET/CT lymphoma exams from 2008-2018 in our clinical imaging database. Deauville scores were removed from the reports and then the remaining text in the reports was used as the model input. Multiple general-purpose transformer language models were used to classify the reports into Deauville scores 1-5. We then adapted the models to the nuclear medicine domain using masked language modeling and assessed its impact on classification performance. The language models were compared against vision models, a multimodal vision language model, and a nuclear medicine physician with seven-fold Monte Carlo cross validation, reported are the mean and standard deviations. Domain adaption improved all language models. For example, BERT improved from 61.3% five-class accuracy to 65.7% following domain adaptation. The best performing model (domain-adapted RoBERTa) achieved a five-class accuracy of 77.4%, which was better than the physician's performance (66%), the best vision model's performance (48.1), and was similar to the multimodal model's performance (77.2). Domain adaptation improved the performance of large language models in interpreting nuclear medicine text reports.
△ Less
Submitted 1 March, 2023;
originally announced March 2023.
-
Issues and Challenges in Applications of Artificial Intelligence to Nuclear Medicine -- The Bethesda Report (AI Summit 2022)
Authors:
Arman Rahmim,
Tyler J. Bradshaw,
Irène Buvat,
Joyita Dutta,
Abhinav K. Jha,
Paul E. Kinahan,
Quanzheng Li,
Chi Liu,
Melissa D. McCradden,
Babak Saboury,
Eliot Siegel,
John J. Sunderland,
Richard L. Wahl
Abstract:
The SNMMI Artificial Intelligence (SNMMI-AI) Summit, organized by the SNMMI AI Task Force, took place in Bethesda, MD on March 21-22, 2022. It brought together various community members and stakeholders from academia, healthcare, industry, patient representatives, and government (NIH, FDA), and considered various key themes to envision and facilitate a bright future for routine, trustworthy use of…
▽ More
The SNMMI Artificial Intelligence (SNMMI-AI) Summit, organized by the SNMMI AI Task Force, took place in Bethesda, MD on March 21-22, 2022. It brought together various community members and stakeholders from academia, healthcare, industry, patient representatives, and government (NIH, FDA), and considered various key themes to envision and facilitate a bright future for routine, trustworthy use of AI in nuclear medicine. In what follows, essential issues, challenges, controversies and findings emphasized in the meeting are summarized.
△ Less
Submitted 7 November, 2022;
originally announced November 2022.
-
Multiple Coulomb Scattering of muons in Lithium Hydride
Authors:
M. Bogomilov,
R. Tsenov,
G. Vankova-Kirilova,
Y. P. Song,
J. Y. Tang,
Z. H. Li,
R. Bertoni,
M. Bonesini,
F. Chignoli,
R. Mazza,
V. Palladino,
A. de Bari,
D. Orestano,
L. Tortora,
Y. Kuno,
H. Sakamoto,
A. Sato,
S. Ishimoto,
M. Chung,
C. K. Sung,
F. Filthaut,
M. Fedorov,
D. Jokovic,
D. Maletic,
M. Savic
, et al. (112 additional authors not shown)
Abstract:
Multiple Coulomb Scattering (MCS) is a well known phenomenon occurring when charged particles traverse materials. Measurements of muons traversing low $Z$ materials made in the MuScat experiment showed that theoretical models and simulation codes, such as GEANT4 (v7.0), over-estimated the scattering. The Muon Ionization Cooling Experiment (MICE) measured the cooling of a muon beam traversing a liq…
▽ More
Multiple Coulomb Scattering (MCS) is a well known phenomenon occurring when charged particles traverse materials. Measurements of muons traversing low $Z$ materials made in the MuScat experiment showed that theoretical models and simulation codes, such as GEANT4 (v7.0), over-estimated the scattering. The Muon Ionization Cooling Experiment (MICE) measured the cooling of a muon beam traversing a liquid hydrogen or lithium hydride (LiH) energy absorber as part of a programme to develop muon accelerator facilities, such as a Neutrino Factory or a Muon Collider. The energy loss and MCS that occur in the absorber material are competing effects that alter the performance of the cooling channel. Therefore measurements of MCS are required in order to validate the simulations used to predict the cooling performance in future accelerator facilities. We report measurements made in the MICE apparatus of MCS using a LiH absorber and muons within the momentum range 160 to 245 MeV/c. The measured RMS scattering width is about 9% smaller than that predicted by the approximate formula proposed by the Particle Data Group. Data at 172, 200 and 240 MeV/c are compared to the GEANT4 (v9.6) default scattering model. These measurements show agreement with this more recent GEANT4 (v9.6) version over the range of incident muon momenta.
△ Less
Submitted 21 September, 2022;
originally announced September 2022.
-
An Algebraic Theory of Non-Relativistic Spin
Authors:
Peter T. J. Bradshaw
Abstract:
In this paper we present a new, elementary derivation of non-relativistic spin using exclusively real algebraic methods. To do this, we formulate a novel method to decompose the domain of a real endomorphism according to its algebraic properties. We reveal non-commutative multipole tensors as the primary physically meaningful observables of spin, and indicate that spin is fundamentally geometric i…
▽ More
In this paper we present a new, elementary derivation of non-relativistic spin using exclusively real algebraic methods. To do this, we formulate a novel method to decompose the domain of a real endomorphism according to its algebraic properties. We reveal non-commutative multipole tensors as the primary physically meaningful observables of spin, and indicate that spin is fundamentally geometric in nature. In so doing, we demonstrate that neither dynamics nor complex numbers are essential to the fundamental description of spin.
△ Less
Submitted 6 October, 2022; v1 submitted 5 July, 2022;
originally announced July 2022.
-
Validation of Monte Carlo Iodine-131 radiopharmaceutical dosimetry workflow using a 3D printed anthropomorphic head and neck phantom
Authors:
David P. Adam,
Joseph Grudzinski,
Ian Bormett,
Benjamin L. Cox,
Ian R. Marsh,
Tyler J. Bradshaw,
Paul Harari,
Bryan Bednarz
Abstract:
Purpose: In this study, we present the creation of an anthropomorphic, head and neck, nuclear medicine phantom and its characterization for the validation of a Monte Carlo, SPECT image based, Iodine-131 RPT dosimetry workflow.
Methods: 3D printing techniques were used to create the anthropomorphic phantom from a patient CT dataset. Three Iodine-131 SPECT/CT imaging studies were performed using a…
▽ More
Purpose: In this study, we present the creation of an anthropomorphic, head and neck, nuclear medicine phantom and its characterization for the validation of a Monte Carlo, SPECT image based, Iodine-131 RPT dosimetry workflow.
Methods: 3D printing techniques were used to create the anthropomorphic phantom from a patient CT dataset. Three Iodine-131 SPECT/CT imaging studies were performed using a homogeneous, Jaszczak, and an anthropomorphic phantom to quantify the SPECT images. The impact of collimator detector response (CDR) modeling and volume-based partial volume corrections (PVC) upon the absorbed dose was calculated using an image based, Geant4 Monte Carlo RPT dosimetry workflow and compared against a ground truth scenario. Finally, uncertainties were quantified in accordance with recent EANM guidelines.
Results: The 3D printed anthropomorphic phantom was an accurate re-creation of patient anatomy including bone. The extrapolated Jaszczak recovery coefficients were greater than that of the 3D printed insert (~22.8 ml) for both the CDR and non-CDR cases. Utilizing Jaszczak phantom PVCs, the absorbed dose was underpredicted by 0.7% and 4.9% without and with CDR, respectively. Utilizing anthropomorphic phantom RCs overpredicted the absorbed dose by 3% both with and without CDR. All dosimetry scenarios that incorporated PVC were within the calculated uncertainty of the activity. The uncertainties in the cumulative activity ranged from 25.6% to 113% for Jaszczak spheres ranging in volume from 0.5 ml to 16 ml.
Conclusion: The accuracy of Monte Carlo-based dosimetry for Iodine-131 RPT in head and neck cancer was validated with an anthropomorphic phantom. Future applications of the phantom could involve 3D printing and characterizing patient specific volumes for more personalized RPT dosimetry estimates.
△ Less
Submitted 3 February, 2022;
originally announced February 2022.
-
AI-based data corrections for attenuation and scatter in PET and SPECT
Authors:
Alan B. McMillan,
Tyler J. Bradshaw
Abstract:
Recent developments in artificial intelligence technology have enabled new developments that can improve attenuation and scatter correction in PET and SPECT. These technologies will enable the use of accurate and quantitative imaging without the need to acquire a CT image, greatly expanding the capability of PET/MRI, PET-only, and SPECT-only scanners. The use of AI to aid in scatter correction wil…
▽ More
Recent developments in artificial intelligence technology have enabled new developments that can improve attenuation and scatter correction in PET and SPECT. These technologies will enable the use of accurate and quantitative imaging without the need to acquire a CT image, greatly expanding the capability of PET/MRI, PET-only, and SPECT-only scanners. The use of AI to aid in scatter correction will lead to improvements in image reconstruction speed, and improve patient throughput. This paper outlines the use of these new tools, surveys contemporary implementation, and discusses their limitations.
△ Less
Submitted 27 August, 2021;
originally announced August 2021.
-
Performance of the MICE diagnostic system
Authors:
The MICE collaboration,
M. Bogomilov,
R. Tsenov,
G. Vankova-Kirilova,
Y. P. Song,
J. Y. Tang,
Z. H. Li,
R. Bertoni,
M. Bonesini,
F. Chignoli,
R. Mazza,
V. Palladino,
A. de Bari,
D. Orestano,
L. Tortora,
Y. Kuno,
H. Sakamoto,
A. Sato,
S. Ishimoto,
M. Chung,
C. K. Sung,
F. Filthaut,
M. Fedorov,
D. Jokovic,
D. Maletic
, et al. (113 additional authors not shown)
Abstract:
Muon beams of low emittance provide the basis for the intense, well-characterised neutrino beams of a neutrino factory and for multi-TeV lepton-antilepton collisions at a muon collider. The international Muon Ionization Cooling Experiment (MICE) has demonstrated the principle of ionization cooling, the technique by which it is proposed to reduce the phase-space volume occupied by the muon beam at…
▽ More
Muon beams of low emittance provide the basis for the intense, well-characterised neutrino beams of a neutrino factory and for multi-TeV lepton-antilepton collisions at a muon collider. The international Muon Ionization Cooling Experiment (MICE) has demonstrated the principle of ionization cooling, the technique by which it is proposed to reduce the phase-space volume occupied by the muon beam at such facilities. This paper documents the performance of the detectors used in MICE to measure the muon-beam parameters, and the physical properties of the liquid hydrogen energy absorber during running.
△ Less
Submitted 16 August, 2021; v1 submitted 10 June, 2021;
originally announced June 2021.
-
Spatial Process Decomposition for Quantitative Imaging Biomarkers Using Multiple Images of Varying Shapes
Authors:
ShengLi Tzeng,
Jun Zhu,
Amy Weisman,
Tyler Bradshaw,
Robert Jeraj
Abstract:
Quantitative imaging biomarkers (QIB) are extracted from medical images in radiomics for a variety of purposes including noninvasive disease detection, cancer monitoring, and precision medicine. The existing methods for QIB extraction tend to be ad-hoc and not reproducible. In this paper, a general and flexible statistical approach is proposed for handling up to three-dimensional medical images in…
▽ More
Quantitative imaging biomarkers (QIB) are extracted from medical images in radiomics for a variety of purposes including noninvasive disease detection, cancer monitoring, and precision medicine. The existing methods for QIB extraction tend to be ad-hoc and not reproducible. In this paper, a general and flexible statistical approach is proposed for handling up to three-dimensional medical images in an objective and principled way. In particular, a model-based spatial process decomposition is developed where the random weights are unique to individual patients for component functions common across patients. Model fitting and selection are based on maximum likelihood, while feature extractions are via optimal prediction of the underlying true image. A simulation study evaluates the properties of the proposed methodology and for illustration, a cancer image data set is analyzed and QIBs are extracted in association with a clinical endpoint.
△ Less
Submitted 26 July, 2019;
originally announced July 2019.
-
First demonstration of ionization cooling by the Muon Ionization Cooling Experiment
Authors:
M. Bogomilov,
R. Tsenov,
G. Vankova-Kirilova,
Y. P. Song,
J. Y. Tang,
Z. H. Li,
R. Bertoni,
M. Bonesini,
F. Chignoli,
R. Mazza,
V. Palladino,
A. de Bari,
D. Orestano,
L. Tortora,
Y. Kuno,
H. Sakamoto,
A. Sato,
S. Ishimoto,
M. Chung,
C. K. Sung,
F. Filthaut,
D. Jokovic,
D. Maletic,
M. Savic,
N. Jovancevic
, et al. (110 additional authors not shown)
Abstract:
High-brightness muon beams of energy comparable to those produced by state-of-the-art electron, proton and ion accelerators have yet to be realised. Such beams have the potential to carry the search for new phenomena in lepton-antilepton collisions to extremely high energy and also to provide uniquely well-characterised neutrino beams. A muon beam may be created through the decay of pions produced…
▽ More
High-brightness muon beams of energy comparable to those produced by state-of-the-art electron, proton and ion accelerators have yet to be realised. Such beams have the potential to carry the search for new phenomena in lepton-antilepton collisions to extremely high energy and also to provide uniquely well-characterised neutrino beams. A muon beam may be created through the decay of pions produced in the interaction of a proton beam with a target. To produce a high-brightness beam from such a source requires that the phase space volume occupied by the muons be reduced (cooled). Ionization cooling is the novel technique by which it is proposed to cool the beam. The Muon Ionization Cooling Experiment collaboration has constructed a section of an ionization cooling cell and used it to provide the first demonstration of ionization cooling. We present these ground-breaking measurements.
△ Less
Submitted 19 July, 2019;
originally announced July 2019.
-
First particle-by-particle measurement of emittance in the Muon Ionization Cooling Experiment
Authors:
The MICE Collaboration,
D. Adams,
D. Adey,
R. Asfandiyarov,
G. Barber,
A. de Bari,
R. Bayes,
V. Bayliss,
R. Bertoni,
V. Blackmore,
A. Blondel,
J. Boehm,
M. Bogomilov,
M. Bonesini,
C. N. Booth,
D. Bowring,
S. Boyd,
T. W. Bradshaw,
A. D. Bross,
C. Brown,
L. Coney,
G. Charnley,
G. T. Chatzitheodoridis,
F. Chignoli,
M. Chung
, et al. (111 additional authors not shown)
Abstract:
The Muon Ionization Cooling Experiment (MICE) collaboration seeks to demonstrate the feasibility of ionization cooling, the technique by which it is proposed to cool the muon beam at a future neutrino factory or muon collider. The emittance is measured from an ensemble of muons assembled from those that pass through the experiment. A pure muon ensemble is selected using a particle-identification s…
▽ More
The Muon Ionization Cooling Experiment (MICE) collaboration seeks to demonstrate the feasibility of ionization cooling, the technique by which it is proposed to cool the muon beam at a future neutrino factory or muon collider. The emittance is measured from an ensemble of muons assembled from those that pass through the experiment. A pure muon ensemble is selected using a particle-identification system that can reject efficiently both pions and electrons. The position and momentum of each muon are measured using a high-precision scintillating-fibre tracker in a 4\,T solenoidal magnetic field. This paper presents the techniques used to reconstruct the phase-space distributions and reports the first particle-by-particle measurement of the emittance of the MICE Muon Beam as a function of muon-beam momentum.
△ Less
Submitted 26 March, 2019; v1 submitted 31 October, 2018;
originally announced October 2018.
-
The liquid-hydrogen absorber for MICE
Authors:
V. Bayliss,
J. Boehm,
T. Bradshaw,
M. Courthold,
S. Harrison,
M. Hills,
P. Hodgson,
S. Ishimoto,
A. Kurup,
W. Lau,
K. Long,
A. Nichols,
D. Summers,
M. Tucker,
P. Warburton,
S. Watson,
C. Whyte
Abstract:
The Muon Ionization Cooling Experiment (MICE) has been built at the STFC Rutherford Appleton Laboratory to demonstrate the principle of muon beam phase-space reduction via ionization cooling. Muon beam cooling will be required at a future proton-derived neutrino factory or muon collider. Ionization cooling is achieved by passing the beam through an energy-absorbing material, such as liquid hydroge…
▽ More
The Muon Ionization Cooling Experiment (MICE) has been built at the STFC Rutherford Appleton Laboratory to demonstrate the principle of muon beam phase-space reduction via ionization cooling. Muon beam cooling will be required at a future proton-derived neutrino factory or muon collider. Ionization cooling is achieved by passing the beam through an energy-absorbing material, such as liquid hydrogen, and then re-accelerating the beam using RF cavities. This paper describes the hydrogen system constructed for MICE including: the liquid-hydrogen absorber, its associated cryogenic and gas systems, the control and monitoring system, and the necessary safety engineering. The performance of the system in cool-down, liquefaction, and stable operation is also presented.
△ Less
Submitted 9 July, 2018;
originally announced July 2018.
-
Design and expected performance of the MICE demonstration of ionization cooling
Authors:
MICE Collaboration,
M. Bogomilov,
R. Tsenov,
G. Vankova-Kirilova,
Y. Song,
J. Tang,
Z. Li,
R. Bertoni,
M. Bonesini,
F. Chignoli,
R. Mazza,
V. Palladino,
A. de Bari,
G. Cecchet,
D. Orestano,
L. Tortora,
Y. Kuno,
S. Ishimoto,
F. Filthaut,
D. Jokovic,
D. Maletic,
M. Savic,
O. M. Hansen,
S. Ramberger,
M. Vretenar
, et al. (107 additional authors not shown)
Abstract:
Muon beams of low emittance provide the basis for the intense, well-characterised neutrino beams necessary to elucidate the physics of flavour at a neutrino factory and to provide lepton-antilepton collisions at energies of up to several TeV at a muon collider. The international Muon Ionization Cooling Experiment (MICE) aims to demonstrate ionization cooling, the technique by which it is proposed…
▽ More
Muon beams of low emittance provide the basis for the intense, well-characterised neutrino beams necessary to elucidate the physics of flavour at a neutrino factory and to provide lepton-antilepton collisions at energies of up to several TeV at a muon collider. The international Muon Ionization Cooling Experiment (MICE) aims to demonstrate ionization cooling, the technique by which it is proposed to reduce the phase-space volume occupied by the muon beam at such facilities. In an ionization-cooling channel, the muon beam passes through a material in which it loses energy. The energy lost is then replaced using RF cavities. The combined effect of energy loss and re-acceleration is to reduce the transverse emittance of the beam (transverse cooling). A major revision of the scope of the project was carried out over the summer of 2014. The revised experiment can deliver a demonstration of ionization cooling. The design of the cooling demonstration experiment will be described together with its predicted cooling performance.
△ Less
Submitted 27 January, 2017; v1 submitted 23 January, 2017;
originally announced January 2017.
-
Pion contamination in the MICE muon beam
Authors:
D. Adams,
A. Alekou,
M. Apollonio,
R. Asfandiyarov,
G. Barber,
P. Barclay,
A. de Bari,
R. Bayes,
V. Bayliss,
R. Bertoni,
V. J. Blackmore,
A. Blondel,
S. Blot,
M. Bogomilov,
M. Bonesini,
C. N. Booth,
D. Bowring,
S. Boyd,
T. W. Bradshaw,
U. Bravar,
A. D. Bross,
M. Capponi,
T. Carlisle,
G. Cecchet,
C. Charnley
, et al. (120 additional authors not shown)
Abstract:
The international Muon Ionization Cooling Experiment (MICE) will perform a systematic investigation of ionization cooling with muon beams of momentum between 140 and 240\,MeV/c at the Rutherford Appleton Laboratory ISIS facility. The measurement of ionization cooling in MICE relies on the selection of a pure sample of muons that traverse the experiment. To make this selection, the MICE Muon Beam i…
▽ More
The international Muon Ionization Cooling Experiment (MICE) will perform a systematic investigation of ionization cooling with muon beams of momentum between 140 and 240\,MeV/c at the Rutherford Appleton Laboratory ISIS facility. The measurement of ionization cooling in MICE relies on the selection of a pure sample of muons that traverse the experiment. To make this selection, the MICE Muon Beam is designed to deliver a beam of muons with less than $\sim$1\% contamination. To make the final muon selection, MICE employs a particle-identification (PID) system upstream and downstream of the cooling cell. The PID system includes time-of-flight hodoscopes, threshold-Cherenkov counters and calorimetry. The upper limit for the pion contamination measured in this paper is $f_π< 1.4\%$ at 90\% C.L., including systematic uncertainties. Therefore, the MICE Muon Beam is able to meet the stringent pion-contamination requirements of the study of ionization cooling.
△ Less
Submitted 10 February, 2016; v1 submitted 2 November, 2015;
originally announced November 2015.
-
Electron-Muon Ranger: performance in the MICE Muon Beam
Authors:
D. Adams,
A. Alekou,
M. Apollonio,
R. Asfandiyarov,
G. Barber,
P. Barclay,
A. de Bari,
R. Bayes,
V. Bayliss,
P. Bene,
R. Bertoni,
V. J. Blackmore,
A. Blondel,
S. Blot,
M. Bogomilov,
M. Bonesini,
C. N. Booth,
D. Bowring,
S. Boyd,
T. W. Bradshaw,
U. Bravar,
A. D. Bross,
F. Cadoux,
M. Capponi,
T. Carlisle
, et al. (129 additional authors not shown)
Abstract:
The Muon Ionization Cooling Experiment (MICE) will perform a detailed study of ionization cooling to evaluate the feasibility of the technique. To carry out this program, MICE requires an efficient particle-identification (PID) system to identify muons. The Electron-Muon Ranger (EMR) is a fully-active tracking-calorimeter that forms part of the PID system and tags muons that traverse the cooling c…
▽ More
The Muon Ionization Cooling Experiment (MICE) will perform a detailed study of ionization cooling to evaluate the feasibility of the technique. To carry out this program, MICE requires an efficient particle-identification (PID) system to identify muons. The Electron-Muon Ranger (EMR) is a fully-active tracking-calorimeter that forms part of the PID system and tags muons that traverse the cooling channel without decaying. The detector is capable of identifying electrons with an efficiency of 98.6%, providing a purity for the MICE beam that exceeds 99.8%. The EMR also proved to be a powerful tool for the reconstruction of muon momenta in the range 100-280 MeV/$c$.
△ Less
Submitted 3 November, 2015; v1 submitted 28 October, 2015;
originally announced October 2015.
-
A facility to Search for Hidden Particles (SHiP) at the CERN SPS
Authors:
SHiP Collaboration,
M. Anelli,
S. Aoki,
G. Arduini,
J. J. Back,
A. Bagulya,
W. Baldini,
A. Baranov,
G. J. Barker,
S. Barsuk,
M. Battistin,
J. Bauche,
A. Bay,
V. Bayliss,
L. Bellagamba,
G. Bencivenni,
M. Bertani,
O. Bezshyyko,
D. Bick,
N. Bingefors,
A. Blondel,
M. Bogomilov,
A. Boyarsky,
D. Bonacorsi,
D. Bondarenko
, et al. (211 additional authors not shown)
Abstract:
A new general purpose fixed target facility is proposed at the CERN SPS accelerator which is aimed at exploring the domain of hidden particles and make measurements with tau neutrinos. Hidden particles are predicted by a large number of models beyond the Standard Model. The high intensity of the SPS 400~GeV beam allows probing a wide variety of models containing light long-lived exotic particles w…
▽ More
A new general purpose fixed target facility is proposed at the CERN SPS accelerator which is aimed at exploring the domain of hidden particles and make measurements with tau neutrinos. Hidden particles are predicted by a large number of models beyond the Standard Model. The high intensity of the SPS 400~GeV beam allows probing a wide variety of models containing light long-lived exotic particles with masses below ${\cal O}$(10)~GeV/c$^2$, including very weakly interacting low-energy SUSY states. The experimental programme of the proposed facility is capable of being extended in the future, e.g. to include direct searches for Dark Matter and Lepton Flavour Violation.
△ Less
Submitted 20 April, 2015;
originally announced April 2015.
-
Characterisation of the muon beams for the Muon Ionisation Cooling Experiment
Authors:
The MICE Collaboration,
D. Adams,
D. Adey,
A. Alekou,
M. Apollonio,
R. Asfandiyarov,
J. Back,
G. Barber,
P. Barclay,
A. de Bari,
R. Bayes,
V. Bayliss,
R. Bertoni,
V. J. Blackmore,
A. Blondel,
S. Blot,
M. Bogomilov,
M. Bonesini,
C. N. Booth,
D. Bowring,
S. Boyd,
T. W. Bradshaw,
U. Bravar,
A. D. Bross,
M. Capponi
, et al. (119 additional authors not shown)
Abstract:
A novel single-particle technique to measure emittance has been developed and used to characterise seventeen different muon beams for the Muon Ionisation Cooling Experiment (MICE). The muon beams, whose mean momenta vary from 171 to 281 MeV/c, have emittances of approximately 1.5--2.3 πmm-rad horizontally and 0.6--1.0 πmm-rad vertically, a horizontal dispersion of 90--190 mm and momentum spreads o…
▽ More
A novel single-particle technique to measure emittance has been developed and used to characterise seventeen different muon beams for the Muon Ionisation Cooling Experiment (MICE). The muon beams, whose mean momenta vary from 171 to 281 MeV/c, have emittances of approximately 1.5--2.3 πmm-rad horizontally and 0.6--1.0 πmm-rad vertically, a horizontal dispersion of 90--190 mm and momentum spreads of about 25 MeV/c. There is reasonable agreement between the measured parameters of the beams and the results of simulations. The beams are found to meet the requirements of MICE.
△ Less
Submitted 11 October, 2013; v1 submitted 6 June, 2013;
originally announced June 2013.
-
MICE: the Muon Ionization Cooling Experiment. Step I: First Measurement of Emittance with Particle Physics Detectors
Authors:
U. Bravar,
M. Bogomilov,
Y. Karadzhov,
D. Kolev,
I. Russinov,
R. Tsenov,
L. Wang,
F. Y. Xu,
S. X. Zheng,
R. Bertoni,
M. Bonesini,
R. Mazza,
V. Palladino,
G. Cecchet,
A. de Bari,
M. Capponi,
A. Iaciofano,
D. Orestano,
F. Pastore,
L. Tortora,
S. Ishimoto,
S. Suzuki,
K. Yoshimura,
Y. Mori,
Y. Kuno
, et al. (123 additional authors not shown)
Abstract:
The Muon Ionization Cooling Experiment (MICE) is a strategic R&D project intended to demonstrate the only practical solution to providing high brilliance beams necessary for a neutrino factory or muon collider. MICE is under development at the Rutherford Appleton Laboratory (RAL) in the United Kingdom. It comprises a dedicated beamline to generate a range of input muon emittances and momenta, with…
▽ More
The Muon Ionization Cooling Experiment (MICE) is a strategic R&D project intended to demonstrate the only practical solution to providing high brilliance beams necessary for a neutrino factory or muon collider. MICE is under development at the Rutherford Appleton Laboratory (RAL) in the United Kingdom. It comprises a dedicated beamline to generate a range of input muon emittances and momenta, with time-of-flight and Cherenkov detectors to ensure a pure muon beam. The emittance of the incoming beam will be measured in the upstream magnetic spectrometer with a scintillating fiber tracker. A cooling cell will then follow, alternating energy loss in Liquid Hydrogen (LH2) absorbers to RF cavity acceleration. A second spectrometer, identical to the first, and a second muon identification system will measure the outgoing emittance. In the 2010 run at RAL the muon beamline and most detectors were fully commissioned and a first measurement of the emittance of the muon beam with particle physics (time-of-flight) detectors was performed. The analysis of these data was recently completed and is discussed in this paper. Future steps for MICE, where beam emittance and emittance reduction (cooling) are to be measured with greater accuracy, are also presented.
△ Less
Submitted 30 July, 2013; v1 submitted 9 October, 2011;
originally announced October 2011.
-
Planck early results. VI. The High Frequency Instrument data processing
Authors:
Planck HFI Core Team,
P. A. R. Ade,
N. Aghanim,
R. Ansari,
M. Arnaud,
M. Ashdown,
J. Aumont,
A. J. Banday,
M. Bartelmann,
J. G. Bartlett,
E. Battaner,
K. Benabed,
A. Benoît,
J. -P. Bernard,
M. Bersanelli,
J. J. Bock,
J. R. Bond,
J. Borrill,
F. R. Bouchet,
F. Boulanger,
T. Bradshaw,
M. Bucher,
J. -F. Cardoso,
G. Castex,
A. Catalano
, et al. (141 additional authors not shown)
Abstract:
We describe the processing of the 336 billion raw data samples from the High Frequency Instrument (HFI) which we performed to produce six temperature maps from the first 295 days of Planck-HFI survey data. These maps provide an accurate rendition of the sky emission at 100, 143, 217, 353, 545 and 857 GHz with an angular resolution ranging from 9.9 to 4.4^2. The white noise level is around 1.5 μK…
▽ More
We describe the processing of the 336 billion raw data samples from the High Frequency Instrument (HFI) which we performed to produce six temperature maps from the first 295 days of Planck-HFI survey data. These maps provide an accurate rendition of the sky emission at 100, 143, 217, 353, 545 and 857 GHz with an angular resolution ranging from 9.9 to 4.4^2. The white noise level is around 1.5 μK degree or less in the 3 main CMB channels (100--217GHz). The photometric accuracy is better than 2% at frequencies between 100 and 353 GHz and around 7% at the two highest frequencies. The maps created by the HFI Data Processing Centre reach our goals in terms of sensitivity, resolution, and photometric accuracy. They are already sufficiently accurate and well-characterised to allow scientific analyses which are presented in an accompanying series of early papers. At this stage, HFI data appears to be of high quality and we expect that with further refinements of the data processing we should be able to achieve, or exceed, the science goals of the Planck project.
△ Less
Submitted 23 December, 2011; v1 submitted 11 January, 2011;
originally announced January 2011.
-
Planck early results: first assessment of the High Frequency Instrument in-flight performance
Authors:
Planck HFI Core Team,
P. A. R. Ade,
N. Aghanim,
R. Ansari,
M. Arnaud,
M. Ashdown,
J. Aumont,
A. J. Banday,
M. Bartelmann,
J. G. Bartlett,
E. Battaner,
K. Benabed,
A. Benot,
J. -P. Bernard,
M. Bersanelli,
R. Bhatia,
J. J. Bock,
J. R. Bond,
J. Borrill,
F. R. Bouchet,
F. Boulanger,
T. Bradshaw,
E. Brelle,
M. Bucher,
P. Camus
, et al. (141 additional authors not shown)
Abstract:
The Planck High Frequency Instrument (HFI) is designed to measure the temperature and polarization anisotropies of the Cosmic Microwave Background and galactic foregrounds in six wide bands centered at 100, 143, 217, 353, 545 and 857 GHz at an angular resolution of 10' (100 GHz), 7' (143 GHz), and 5' (217 GHz and higher). HFI has been operating flawlessly since launch on 14 May 2009. The bolometer…
▽ More
The Planck High Frequency Instrument (HFI) is designed to measure the temperature and polarization anisotropies of the Cosmic Microwave Background and galactic foregrounds in six wide bands centered at 100, 143, 217, 353, 545 and 857 GHz at an angular resolution of 10' (100 GHz), 7' (143 GHz), and 5' (217 GHz and higher). HFI has been operating flawlessly since launch on 14 May 2009. The bolometers cooled to 100 mK as planned. The settings of the readout electronics, such as the bolometer bias current, that optimize HFI's noise performance on orbit are nearly the same as the ones chosen during ground testing. Observations of Mars, Jupiter, and Saturn verified both the optical system and the time response of the detection chains. The optical beams are close to predictions from physical optics modeling. The time response of the detection chains is close to pre-launch measurements. The detectors suffer from an unexpected high flux of cosmic rays related to low solar activity. Due to the redundancy of Planck's observations strategy, the removal of a few percent of data contaminated by glitches does not affect significantly the sensitivity. The cosmic rays heat up significantly the bolometer plate and the modulation on periods of days to months of the heat load creates a common drift of all bolometer signals which do not affect the scientific capabilities. Only the high energy cosmic rays showers induce inhomogeneous heating which is a probable source of low frequency noise.
△ Less
Submitted 11 January, 2011;
originally announced January 2011.
-
Planck Early Results. II. The thermal performance of Planck
Authors:
Planck Collaboration,
P. A. R. Ade,
N. Aghanim,
M. Arnaud,
M. Ashdown,
J. Aumont,
C. Baccigalupi,
M. Baker,
A. Balbi,
A. J. Banday,
R. B. Barreiro,
E. Battaner,
K. Benabed,
A. Benoit,
J. P. Bernard,
M. Bersanelli,
P. Bhandari,
R. Bhatia,
J. J. Bock,
A. Bonaldi,
J. R. Bond,
J. Borders,
J. Borrill,
F. R. Bouchet,
B. Bowman
, et al. (203 additional authors not shown)
Abstract:
The performance of the Planck instruments in space is enabled by their low operating temperatures, 20K for LFI and 0.1K for HFI, achieved through a combination of passive radiative cooling and three active mechanical coolers. The scientific requirement for very broad frequency coverage led to two detector technologies with widely different temperature and cooling needs. Active coolers could satisf…
▽ More
The performance of the Planck instruments in space is enabled by their low operating temperatures, 20K for LFI and 0.1K for HFI, achieved through a combination of passive radiative cooling and three active mechanical coolers. The scientific requirement for very broad frequency coverage led to two detector technologies with widely different temperature and cooling needs. Active coolers could satisfy these needs; a helium cryostat, as used by previous cryogenic space missions (IRAS, COBE, ISO, Spitzer, AKARI), could not. Radiative cooling is provided by three V-groove radiators and a large telescope baffle. The active coolers are a hydrogen sorption cooler (<20K), a 4He Joule-Thomson cooler (4.7K), and a 3He-4He dilution cooler (1.4K and 0.1K). The flight system was at ambient temperature at launch and cooled in space to operating conditions. The HFI bolometer plate reached 93mK on 3 July 2009, 50 days after launch. The solar panel always faces the Sun, shadowing the rest of Planck, andoperates at a mean temperature of 384K. At the other end of the spacecraft, the telescope baffle operates at 42.3K and the telescope primary mirror operates at 35.9K. The temperatures of key parts of the instruments are stabilized by both active and passive methods. Temperature fluctuations are driven by changes in the distance from the Sun, sorption cooler cycling and fluctuations in gas-liquid flow, and fluctuations in cosmic ray flux on the dilution and bolometer plates. These fluctuations do not compromise the science data.
△ Less
Submitted 2 January, 2012; v1 submitted 11 January, 2011;
originally announced January 2011.
-
Planck Early Results: The Planck mission
Authors:
Planck Collaboration,
P. A. R. Ade,
N. Aghanim,
M. Arnaud,
M. Ashdown,
J. Aumont,
C. Baccigalupi,
M. Baker,
A. Balbi,
A. J. Banday,
R. B. Barreiro,
J. G. Bartlett,
E. Battaner,
K. Benabed,
K. Bennett,
A. Benoît,
J. -P. Bernard,
M. Bersanelli,
R. Bhatia,
J. J. Bock,
A. Bonaldi,
J. R. Bond,
J. Borrill,
F. R. Bouchet,
T. Bradshaw
, et al. (250 additional authors not shown)
Abstract:
The European Space Agency's Planck satellite was launched on 14 May 2009, and has been surveying the sky stably and continuously since 13 August 2009. Its performance is well in line with expectations, and it will continue to gather scientific data until the end of its cryogenic lifetime. We give an overview of the history of Planck in its first year of operations, and describe some of the key per…
▽ More
The European Space Agency's Planck satellite was launched on 14 May 2009, and has been surveying the sky stably and continuously since 13 August 2009. Its performance is well in line with expectations, and it will continue to gather scientific data until the end of its cryogenic lifetime. We give an overview of the history of Planck in its first year of operations, and describe some of the key performance aspects of the satellite. This paper is part of a package submitted in conjunction with Planck's Early Release Compact Source Catalogue, the first data product based on Planck to be released publicly. The package describes the scientific performance of the Planck payload, and presents results on a variety of astrophysical topics related to the sources included in the Catalogue, as well as selected topics on diffuse emission.
△ Less
Submitted 16 June, 2011; v1 submitted 11 January, 2011;
originally announced January 2011.
-
Status of COLDDIAG: A Cold Vacuum Chamber for Diagnostics
Authors:
S. Gerstl,
T. Baumbach,
S. Casalbuoni,
A. W. Grau,
M. Hagelstein,
D. Saez de Jauregui,
C. Boffo,
G. Sikler,
V. Baglin,
M. P. Cox,
J. C. Schouten,
R. Cimino,
M. Commisso,
B. Spataro,
A. Mostacci,
E. J. Wallén,
R. Weigel,
J. Clarke,
D. Scott,
T. W. Bradshaw,
R. M. Jones,
I. R. R. Shinton
Abstract:
One of the still open issues for the development of superconducting insertion devices is the understanding of the beam heat load. With the aim of measuring the beam heat load to a cold bore and the hope to gain a deeper understanding in the beam heat load mechanisms, a cold vacuum chamber for diagnostics is under construction. The following diagnostics will be implemented: i) retarding field analy…
▽ More
One of the still open issues for the development of superconducting insertion devices is the understanding of the beam heat load. With the aim of measuring the beam heat load to a cold bore and the hope to gain a deeper understanding in the beam heat load mechanisms, a cold vacuum chamber for diagnostics is under construction. The following diagnostics will be implemented: i) retarding field analyzers to measure the electron energy and flux, ii) temperature sensors to measure the total heat load, iii) pressure gauges, iv) and mass spectrometers to measure the gas content. The inner vacuum chamber will be removable in order to test different geometries and materials. This will allow the installation of the cryostat in different synchrotron light sources. COLDDIAG will be built to fit in a short straight section at ANKA. A first installation at the synchrotron light source Diamond is foreseen in June 2011. Here we describe the technical design report of this device and the planned measurements with beam.
△ Less
Submitted 1 June, 2010;
originally announced June 2010.
-
Challenge of polarized beams at future colliders
Authors:
G. Moortgat-Pick,
I. R. Bailey,
D. P. Barber,
E. Baynham,
A. Birch,
T. Bradshaw,
A. Brummitt,
S. Carr,
J. A. Clarke,
P. Cooke,
J. B. Dainton,
T. Hartin,
Y. Ivanyushenkov,
L. J. Jenner,
A. Lintern,
L. I. Malysheva,
O. B. Malyshev,
J. Rochford,
S. Riemann,
A. Schälicke,
P. Schmid,
D. J. Scott,
A. Ushakov,
L. Zang
Abstract:
A short overview about the potential of polarized beams at future colliders is given. In particular the baseline design for polarized beams at the ILC is presented and the physics case for polarized $e^-$ and $e^+$ is discussed. In order to fulfil the precision requirements spin tracking from the source to the interaction point is needed. Updates concerning the theoretical calculations as well a…
▽ More
A short overview about the potential of polarized beams at future colliders is given. In particular the baseline design for polarized beams at the ILC is presented and the physics case for polarized $e^-$ and $e^+$ is discussed. In order to fulfil the precision requirements spin tracking from the source to the interaction point is needed. Updates concerning the theoretical calculations as well as their implementation in simulation codes are reported.
△ Less
Submitted 15 January, 2008;
originally announced January 2008.