-
Interim report for the International Muon Collider Collaboration (IMCC)
Authors:
C. Accettura,
S. Adrian,
R. Agarwal,
C. Ahdida,
C. Aimé,
A. Aksoy,
G. L. Alberghi,
S. Alden,
N. Amapane,
D. Amorim,
P. Andreetto,
F. Anulli,
R. Appleby,
A. Apresyan,
P. Asadi,
M. Attia Mahmoud,
B. Auchmann,
J. Back,
A. Badea,
K. J. Bae,
E. J. Bahng,
L. Balconi,
F. Balli,
L. Bandiera,
C. Barbagallo
, et al. (362 additional authors not shown)
Abstract:
The International Muon Collider Collaboration (IMCC) [1] was established in 2020 following the recommendations of the European Strategy for Particle Physics (ESPP) and the implementation of the European Strategy for Particle Physics-Accelerator R&D Roadmap by the Laboratory Directors Group [2], hereinafter referred to as the the European LDG roadmap. The Muon Collider Study (MuC) covers the accele…
▽ More
The International Muon Collider Collaboration (IMCC) [1] was established in 2020 following the recommendations of the European Strategy for Particle Physics (ESPP) and the implementation of the European Strategy for Particle Physics-Accelerator R&D Roadmap by the Laboratory Directors Group [2], hereinafter referred to as the the European LDG roadmap. The Muon Collider Study (MuC) covers the accelerator complex, detectors and physics for a future muon collider. In 2023, European Commission support was obtained for a design study of a muon collider (MuCol) [3]. This project started on 1st March 2023, with work-packages aligned with the overall muon collider studies. In preparation of and during the 2021-22 U.S. Snowmass process, the muon collider project parameters, technical studies and physics performance studies were performed and presented in great detail. Recently, the P5 panel [4] in the U.S. recommended a muon collider R&D, proposed to join the IMCC and envisages that the U.S. should prepare to host a muon collider, calling this their "muon shot". In the past, the U.S. Muon Accelerator Programme (MAP) [5] has been instrumental in studies of concepts and technologies for a muon collider.
△ Less
Submitted 17 July, 2024;
originally announced July 2024.
-
Scintillation Properties of CsPbBr3 Nanocrystals Prepared by Ligand-Assisted Reprecipitation and Dual Effect of Polyacrylate Encapsulation toward Scalable Ultrafast Radiation Detectors
Authors:
Francesca Cova,
Andrea Erroi,
Matteo L. Zaffalon,
Alessia Cemmi,
Ilaria Di Sarcina,
Jacopo Perego,
Angelo Monguzzi,
Angiolina Comotti,
Francesca Rossi,
Francesco Carulli,
Sergio Brovelli
Abstract:
Lead halide perovskite nanocrystals (LHP-NCs) embedded in polymeric hosts are gaining attention as scalable and low-cost scintillation detectors for technologically relevant applications. Despite rapid progress, little is currently known about the scintillation properties and stability of LHP-NCs prepared by the ligand assisted reprecipitation (LARP) method, which allows mass scalability at room t…
▽ More
Lead halide perovskite nanocrystals (LHP-NCs) embedded in polymeric hosts are gaining attention as scalable and low-cost scintillation detectors for technologically relevant applications. Despite rapid progress, little is currently known about the scintillation properties and stability of LHP-NCs prepared by the ligand assisted reprecipitation (LARP) method, which allows mass scalability at room temperature unmatched by any other type of nanostructure, and the implications of incorporating LHP-NCs into polyacrylate hosts are still largely debated. Here, we show that LARP-synthesized CsPbBr3 NCs are comparable to particles from hot-injection routes and unravel the dual effect of polyacrylate incorporation, where the partial degradation of LHP-NCs luminescence is counterbalanced by the passivation of electron-poor defects by the host acrylic groups. Experiments on NCs with tailored surface defects show that the balance between such antithetical effects of polymer embedding is determined by the surface defect density of the NCs and provide guidelines for further material optimization.
△ Less
Submitted 19 June, 2024;
originally announced June 2024.
-
Ultrafast nanocomposite scintillators based on Cd-enhanced CsPbCl3 nanocrystals in polymer matrix
Authors:
Andrea Erroi,
Francesco Carulli,
Francesca Cova,
Isabel Frank,
Matteo L. Zaffalon,
Jordi Llusar,
Sara Mecca,
Alessia Cemmi,
Ilaria Di Sarcina,
Francesca Rossi,
Luca Beverina,
Francesco Meinardi,
Ivan Infante,
Etiennette Auffray,
Sergio Brovelli
Abstract:
Lead halide perovskite nanocrystals (LHP-NCs) embedded in polymer matrices are gaining traction for next-generation radiation detectors. While progress has been made on green-emitting CsPbBr3 NCs, scant attention has been given to the scintillation properties of CsPbCl3 NCs, which emit size-tunable UV-blue light matching the peak efficiency of ultrafast photodetectors. In this study, we explore th…
▽ More
Lead halide perovskite nanocrystals (LHP-NCs) embedded in polymer matrices are gaining traction for next-generation radiation detectors. While progress has been made on green-emitting CsPbBr3 NCs, scant attention has been given to the scintillation properties of CsPbCl3 NCs, which emit size-tunable UV-blue light matching the peak efficiency of ultrafast photodetectors. In this study, we explore the scintillation characteristics of CsPbCl3 NCs produced through a scalable method and treated with CdCl2. Spectroscopic, radiometric and theoretical analysis on both untreated and treated NCs uncover deep hole trap states due to surface undercoordinated chloride ions, eliminated by Pb to Cd substitution. This yields near-perfect efficiency and resistance to polyacrylate mass-polymerization. Radiation hardness tests demonstrate stability to high gamma doses while time-resolved experiments reveal ultrafast radioluminescence with an average lifetime as short as 210 ps. These findings enhance our comprehension of LHP NCs' scintillation properties, positioning CsPbCl3 as a promising alternative to conventional fast scintillators.
△ Less
Submitted 23 April, 2024;
originally announced April 2024.
-
Comparative characterization study of LYSO:Ce crystals for timing applications
Authors:
F. M. Addesa,
P. Barria,
R. Bianco,
M. Campana,
F. Cavallari,
A. Cemmi,
M. Cipriani,
I. Dafinei,
B. ď Orsi,
D. del Re,
M. Diemoz,
G. ď Imperio,
E. Di Marco,
I. Di Sarcina,
M. Enculescu,
E. Longo,
M. T. Lucchini,
F. Marchegiani,
P. Meridiani,
S. Nisi,
G. Organtini,
F. Pandolfi,
R. Paramatti,
V. Pettinacci,
C. Quaranta
, et al. (6 additional authors not shown)
Abstract:
Cerium-doped Lutetium-Yttrium Oxyorthosilicate (LYSO:Ce)is one of the most widely used Cerium-doped Lutetium based scintillation crystals. Initially developed for medical detectors it rapidly became attractive for High Energy Particle Physics (HEP) applications, especially in the frame of high luminosity particle colliders. In this paper, a comprehensive and systematic study of LYSO:Ce (…
▽ More
Cerium-doped Lutetium-Yttrium Oxyorthosilicate (LYSO:Ce)is one of the most widely used Cerium-doped Lutetium based scintillation crystals. Initially developed for medical detectors it rapidly became attractive for High Energy Particle Physics (HEP) applications, especially in the frame of high luminosity particle colliders. In this paper, a comprehensive and systematic study of LYSO:Ce ($[Lu_{(1-x)}Y_x]_2SiO_5$:$Ce$) crystals is presented. It involves for the first time a large number of crystal samples (180) of the same size from a dozen of producers.The study consists of a comparative characterization of LYSO:Ce crystal products available on the market by mechanical, optical and scintillation measurements and aims specifically, to investigate key parameters of timing applications for HEP.
△ Less
Submitted 3 June, 2022; v1 submitted 30 May, 2022;
originally announced May 2022.
-
Radiation study of Lead Fluoride crystals
Authors:
A. Cemmi,
A. Colangeli,
B. D'orsi,
I. Di Sarcina,
E. Diociaiuti,
S. Fiore,
D. Paesani,
M. Pillon,
A. Saputi,
I. Sarra,
D. Tagnani
Abstract:
Lead fluoride (PbF$_2$) crystals represent an excellent and relatively innovative choice for high resolution electromagnetic calorimeters with high granularity and fast timing for high intensity environments. For this reason two PbF$_2$ crystals, sized $5\times 5 \times 40 $ mm$^3$, were irradiated with $^{60}$Co photons up to $\sim 4$ Mrad and with 14 MeV neutrons up to a $10^{13}$ n/cm$^2$ total…
▽ More
Lead fluoride (PbF$_2$) crystals represent an excellent and relatively innovative choice for high resolution electromagnetic calorimeters with high granularity and fast timing for high intensity environments. For this reason two PbF$_2$ crystals, sized $5\times 5 \times 40 $ mm$^3$, were irradiated with $^{60}$Co photons up to $\sim 4$ Mrad and with 14 MeV neutrons up to a $10^{13}$ n/cm$^2$ total fluence. Their loss in transmittance was evaluated at different steps of the photon and neutron irradiation campaign, resulting in a total of 30% loss above 350 nm. With crystals always kept in dark conditions, natural and thermal annealing, as well as optical bleaching with 400 nm light, were performed on the irradiated specimens, resulting in a partial recovery of their original optical characteristics.
△ Less
Submitted 14 April, 2022; v1 submitted 26 July, 2021;
originally announced July 2021.
-
Irradiation study of UV Silicon Photomultipliers for the Mu2e Calorimeter
Authors:
S. Baccaro,
A. Cemmi,
M. Cordelli,
E. Diociaiuti,
R. Donghia,
A. Ferrari,
S. Giovannella,
S. Miscetti,
S. Müller,
M. Pillon,
I. Sarra
Abstract:
The Mu2e calorimeter is composed of 1400 un-doped CsI crystals, coupled to large area UV extended Silicon Photomultipliers (SiPMs), arranged in two annular disks. This calorimeter has to provide precise information on energy, timing and position resolutions. It should also be fast enough to handle the high rate background and it must operate and survive in the high radiation environment. Simulatio…
▽ More
The Mu2e calorimeter is composed of 1400 un-doped CsI crystals, coupled to large area UV extended Silicon Photomultipliers (SiPMs), arranged in two annular disks. This calorimeter has to provide precise information on energy, timing and position resolutions. It should also be fast enough to handle the high rate background and it must operate and survive in the high radiation environment. Simulation studies estimated that, in the highest irradiated regions, each photo-sensor will absorb a dose of 20 krad and will be exposed to a neutron fluency of 5.5x10^11 n_(1MeV)/cm^2 in three years of running, with a safety factor of 3 included. At the end of 2015, we have concluded an irradiation campaign at the Frascati Neutron Generator (FNG, Frascati, Italy) measuring the response of two different 16 array models from Hamamatsu, which differ for the protection windows and a SiPM from FBK. In 2016, we have carried out two additional irradiation campaigns with neutrons and photons at the Helmholtz-Zentrum Dresden-Rossendorf (HZDR, Dresden, Germany) and at the Calliope gamma irradiation facility at ENEA-Casaccia, respectively. A negligible increment of the leakage current and no gain change have been observed with the dose irradiation. On the other hand, at the end of the neutron irradiation, the gain does not show large changes whilst the leakage current increases by around a factor of 2000. In these conditions, the too high leakage current makes problematic to bias the SiPMs, thus requiring to cool them down to a running temperature of ~0 °C.
△ Less
Submitted 23 January, 2017;
originally announced January 2017.
-
Radiation hardness test of un-doped CsI crystals and Silicon Photomultipliers for the Mu2e calorimeter
Authors:
Stefania Baccaro,
Alessia Cemmi,
Marco Cordelli,
Eleonora Diociaiuti,
Raffaella Donghia,
Simona Giovannella,
Stefano Loreti,
Stefano Miscetti,
Mario Pillon,
Ivano Sarra
Abstract:
The Mu2e calorimeter is composed by 1400 un-doped CsI crystals coupled to large area UV extended Silicon Photomultipliers arranged in two annular disks. This calorimeter has to provide precise information on energy, timing and position. It should also be fast enough to handle the high rate background and it must operate and survive in a high radiation environment. Simulation studies estimated that…
▽ More
The Mu2e calorimeter is composed by 1400 un-doped CsI crystals coupled to large area UV extended Silicon Photomultipliers arranged in two annular disks. This calorimeter has to provide precise information on energy, timing and position. It should also be fast enough to handle the high rate background and it must operate and survive in a high radiation environment. Simulation studies estimated that, in the hottest regions, each crystal will absorb a dose of 300 Gy and will be exposed to a neutron fluency of 6 x 10^{11} n/cm^2 in 3 years of running.
Test of un-doped CsI crystals irradiated up to 900 Gy and to a neutron fluency up to 9 x 10^{11} n/cm^2 have been performed at CALLIOPE and FNG ENEA facilities in Italy. We present our study on the variation of light yield (LY) and longitudinal response uniformity (LRU) of these crystals after irradiation. The ionization dose does not modify LRU while a 20% reduction in LY is observed at 900 Gy. Similarly, the neutron flux causes an acceptable LY deterioration (<15%). A neutron irradiation test on different types of SIPMs (two different array models from Hamamatsu and one from FBK) have also been carried out by measuring the variation of the leakage current and the charge response to an ultraviolet led. We concluded that, in the experiment, we will need to cool down the SIPMs to 0 C reduce the leakage current to an acceptable level.
△ Less
Submitted 23 June, 2016;
originally announced June 2016.
-
Longitudinal uniformity, time performance and irradiation test of pure CsI crystals
Authors:
M. Angelucci,
O. Atanova,
S. Baccaro,
A. Cemmi,
M. Cordelli,
R. Donghia,
S. Giovannella,
F. Happacher,
S. Miscetti,
I. Sarra,
S. R. Soleti
Abstract:
To study an alternative to BaF2, as the crystal choice for the Mu2e calorimeter, thirteen pure CsI crystals from Opto Materials and ISMA producers have been characterized by determining their light yield (LY) and longitudinal response uniformity (LRU), when read with a UV extended PMT. The crystals show a LY of ~ 100 p.e./MeV (~ 150 p.e./MeV) when wrapped with Tyvek and coupled to the PMT without…
▽ More
To study an alternative to BaF2, as the crystal choice for the Mu2e calorimeter, thirteen pure CsI crystals from Opto Materials and ISMA producers have been characterized by determining their light yield (LY) and longitudinal response uniformity (LRU), when read with a UV extended PMT. The crystals show a LY of ~ 100 p.e./MeV (~ 150 p.e./MeV) when wrapped with Tyvek and coupled to the PMT without (with) optical grease. The LRU is well represented by a linear slope that is on average around -0.6 %/cm. The timing performances of the Opto Materials crystal, read with a UV extended MPPC, have been evaluated with minimum ionizing particles. A timing resolution of ~ 330 ps (~ 440 ps) is achieved when connecting the photosensor to the MPPC with (without) optical grease. The crystal radiation hardness to a ionization dose has also been studied for one pure CsI crystal from SICCAS. After exposing it to a dose of 900 Gy, a decrease of 33% in the LY is observed while the LRU remains unchanged.
△ Less
Submitted 21 June, 2016;
originally announced June 2016.