-
Interim report for the International Muon Collider Collaboration (IMCC)
Authors:
C. Accettura,
S. Adrian,
R. Agarwal,
C. Ahdida,
C. Aimé,
A. Aksoy,
G. L. Alberghi,
S. Alden,
N. Amapane,
D. Amorim,
P. Andreetto,
F. Anulli,
R. Appleby,
A. Apresyan,
P. Asadi,
M. Attia Mahmoud,
B. Auchmann,
J. Back,
A. Badea,
K. J. Bae,
E. J. Bahng,
L. Balconi,
F. Balli,
L. Bandiera,
C. Barbagallo
, et al. (362 additional authors not shown)
Abstract:
The International Muon Collider Collaboration (IMCC) [1] was established in 2020 following the recommendations of the European Strategy for Particle Physics (ESPP) and the implementation of the European Strategy for Particle Physics-Accelerator R&D Roadmap by the Laboratory Directors Group [2], hereinafter referred to as the the European LDG roadmap. The Muon Collider Study (MuC) covers the accele…
▽ More
The International Muon Collider Collaboration (IMCC) [1] was established in 2020 following the recommendations of the European Strategy for Particle Physics (ESPP) and the implementation of the European Strategy for Particle Physics-Accelerator R&D Roadmap by the Laboratory Directors Group [2], hereinafter referred to as the the European LDG roadmap. The Muon Collider Study (MuC) covers the accelerator complex, detectors and physics for a future muon collider. In 2023, European Commission support was obtained for a design study of a muon collider (MuCol) [3]. This project started on 1st March 2023, with work-packages aligned with the overall muon collider studies. In preparation of and during the 2021-22 U.S. Snowmass process, the muon collider project parameters, technical studies and physics performance studies were performed and presented in great detail. Recently, the P5 panel [4] in the U.S. recommended a muon collider R&D, proposed to join the IMCC and envisages that the U.S. should prepare to host a muon collider, calling this their "muon shot". In the past, the U.S. Muon Accelerator Programme (MAP) [5] has been instrumental in studies of concepts and technologies for a muon collider.
△ Less
Submitted 17 July, 2024;
originally announced July 2024.
-
Towards a Muon Collider
Authors:
Carlotta Accettura,
Dean Adams,
Rohit Agarwal,
Claudia Ahdida,
Chiara Aimè,
Nicola Amapane,
David Amorim,
Paolo Andreetto,
Fabio Anulli,
Robert Appleby,
Artur Apresyan,
Aram Apyan,
Sergey Arsenyev,
Pouya Asadi,
Mohammed Attia Mahmoud,
Aleksandr Azatov,
John Back,
Lorenzo Balconi,
Laura Bandiera,
Roger Barlow,
Nazar Bartosik,
Emanuela Barzi,
Fabian Batsch,
Matteo Bauce,
J. Scott Berg
, et al. (272 additional authors not shown)
Abstract:
A muon collider would enable the big jump ahead in energy reach that is needed for a fruitful exploration of fundamental interactions. The challenges of producing muon collisions at high luminosity and 10 TeV centre of mass energy are being investigated by the recently-formed International Muon Collider Collaboration. This Review summarises the status and the recent advances on muon colliders desi…
▽ More
A muon collider would enable the big jump ahead in energy reach that is needed for a fruitful exploration of fundamental interactions. The challenges of producing muon collisions at high luminosity and 10 TeV centre of mass energy are being investigated by the recently-formed International Muon Collider Collaboration. This Review summarises the status and the recent advances on muon colliders design, physics and detector studies. The aim is to provide a global perspective of the field and to outline directions for future work.
△ Less
Submitted 27 November, 2023; v1 submitted 15 March, 2023;
originally announced March 2023.
-
Muon detection in electron-positron annihilation for muon collider studies
Authors:
N. Amapane,
M. Antonelli,
F. Anulli,
G. Ballerini,
L. Bandiera,
N. Bartosik,
M. Bauce,
A. Bertolin,
C. Biino,
O. R. Blanco- Garcia,
M. Boscolo,
C. Brizzolari,
A. Cappati,
F. Casaburo,
M. Casarsa,
G. Cavoto,
G. Cesarini,
F. Collamati,
G. Cotto,
C. Curatolo,
R. Di Nardo,
F. Gonella,
S. Hoh,
M. Iafrati,
F. Iacoangeli
, et al. (21 additional authors not shown)
Abstract:
The investigation of the energy frontier in physics requires novel concepts for future colliders. The idea of a muon collider is very appealing since it would allow to study particle collisions at up to tens of TeV energy, while offering a cleaner experimental environment with respect to hadronic colliders. One key element in the muon collider design is the low-emittance muon production. Recently,…
▽ More
The investigation of the energy frontier in physics requires novel concepts for future colliders. The idea of a muon collider is very appealing since it would allow to study particle collisions at up to tens of TeV energy, while offering a cleaner experimental environment with respect to hadronic colliders. One key element in the muon collider design is the low-emittance muon production. Recently,the Low EMittance Muon Accelerator (LEMMA) collaboration has explored the muon pair production close to its kinematic threshold by annihilating 45 GeV positrons with electrons in a low Z material target. In this configuration, muons are emerging from the target with a naturally low-emittance. In this paper we describe the performance of a system, to study this production mechanism, that consists in several segmented absorbers with alternating active layers composed of fast Cherenkov detectors together with a muon identification technique based on this detector. Passive layers were made of tungsten. We collected data corresponding to muon and electron beams produced at the H2 line in the North Area of the European Organization for Nuclear Research (CERN) in September 2018.
△ Less
Submitted 31 October, 2021; v1 submitted 26 May, 2021;
originally announced May 2021.
-
Advanced assessment of Beam Induced Background at a Muon Collider
Authors:
Francesco Collamati,
Camilla Curatolo,
Donatella Lucchesi,
Alessio Mereghetti,
Nikolai Mokhov,
Mark Palmer,
Paola Sala
Abstract:
Renewed international interest in muon colliders motivates the continued investigation of the impacts of beam-induced background on detector performance. This continues the effort initiated by the Muon Accelerator Program and carried out until 2017. The beam-induced background from muon decays directly impacts detector performance and must be mitigated by optimizing the overall machine design, wit…
▽ More
Renewed international interest in muon colliders motivates the continued investigation of the impacts of beam-induced background on detector performance. This continues the effort initiated by the Muon Accelerator Program and carried out until 2017. The beam-induced background from muon decays directly impacts detector performance and must be mitigated by optimizing the overall machine design, with particular attention paid to the machine detector interface region. In order to produce beam-induced background events and to study their characteristics in coordination with the collider optimization, a flexible simulation approach is needed. To achieve this goal we have chosen to utilize the combination of LineBuilder and Monte Carlo FLUKA codes. We report the results of beam-induced background studies with these tools obtained for a 1.5 TeV center of mass energy collider configuration. Good agreement with previous simulations using the MARS15 code demonstrate that our choice of tools meet the accuracy and performance requirements to perform future optimization studies on muon collider designs.
△ Less
Submitted 1 October, 2021; v1 submitted 19 May, 2021;
originally announced May 2021.
-
A CUPID Li$_{2}$$^{100}$MoO$_4$ scintillating bolometer tested in the CROSS underground facility
Authors:
The CUPID Interest Group,
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
I. C. Bandac,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergé,
Ch. Bourgeois,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. M. Calvo-Mozota,
J. Camilleri
, et al. (156 additional authors not shown)
Abstract:
A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2β$ experiment CUPID. The measurements were performed at 18 an…
▽ More
A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2β$ experiment CUPID. The measurements were performed at 18 and 12 mK temperature in a pulse tube dilution refrigerator. This setup utilizes the same technology as the CUORE cryostat that will host CUPID and so represents an accurate estimation of the expected performance. The Li$_{2}$$^{100}$MoO$_4$ bolometer shows a high energy resolution of 6 keV FWHM at the 2615 keV $γ$ line. The detection of scintillation light for each event triggered by the Li$_{2}$$^{100}$MoO$_4$ bolometer allowed for a full separation ($\sim$8$σ$) between $γ$($β$) and $α$ events above 2 MeV. The Li$_{2}$$^{100}$MoO$_4$ crystal also shows a high internal radiopurity with $^{228}$Th and $^{226}$Ra activities of less than 3 and 8 $μ$Bq/kg, respectively. Taking also into account the advantage of a more compact and massive detector array, which can be made of cubic-shaped crystals (compared to the cylindrical ones), this test demonstrates the great potential of cubic Li$_{2}$$^{100}$MoO$_4$ scintillating bolometers for high-sensitivity searches for the $^{100}$Mo $0\nu2β$ decay in CROSS and CUPID projects.
△ Less
Submitted 27 November, 2020;
originally announced November 2020.
-
Characterization of cubic Li$_{2}$$^{100}$MoO$_4$ crystals for the CUPID experiment
Authors:
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
A. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergè,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti
, et al. (147 additional authors not shown)
Abstract:
The CUPID Collaboration is designing a tonne-scale, background-free detector to search for double beta decay with sufficient sensitivity to fully explore the parameter space corresponding to the inverted neutrino mass hierarchy scenario. One of the CUPID demonstrators, CUPID-Mo, has proved the potential of enriched Li$_{2}$$^{100}$MoO$_4$ crystals as suitable detectors for neutrinoless double beta…
▽ More
The CUPID Collaboration is designing a tonne-scale, background-free detector to search for double beta decay with sufficient sensitivity to fully explore the parameter space corresponding to the inverted neutrino mass hierarchy scenario. One of the CUPID demonstrators, CUPID-Mo, has proved the potential of enriched Li$_{2}$$^{100}$MoO$_4$ crystals as suitable detectors for neutrinoless double beta decay search. In this work, we characterised cubic crystals that, compared to the cylindrical crystals used by CUPID-Mo, are more appealing for the construction of tightly packed arrays. We measured an average energy resolution of (6.7$\pm$0.6) keV FWHM in the region of interest, approaching the CUPID target of 5 keV FWHM. We assessed the identification of $α$ particles with and without a reflecting foil that enhances the scintillation light collection efficiency, proving that the baseline design of CUPID already ensures a complete suppression of this $α$-induced background contribution. We also used the collected data to validate a Monte Carlo simulation modelling the light collection efficiency, which will enable further optimisations of the detector.
△ Less
Submitted 27 November, 2020;
originally announced November 2020.
-
Novel technique for the study of pile-up events in cryogenic bolometers
Authors:
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
A. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergé,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti
, et al. (144 additional authors not shown)
Abstract:
Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pile-up rejection capability of cryogenic bolometers. Our ap…
▽ More
Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pile-up rejection capability of cryogenic bolometers. Our approach, which consists of producing controlled pile-up events with a programmable waveform generator, has the benefit that we can reliably and reproducibly control the time separation and relative energy of the individual components of the generated pile-up events. The resulting data allow us to optimize and benchmark analysis strategies to discriminate between individual and pile-up pulses. We describe a test of this technique performed with a small array of detectors at the Laboratori Nazionali del Gran Sasso, in Italy; we obtain a 90% rejection efficiency against pulser-generated pile-up events with rise time of ~15ms down to time separation between the individual events of about 2ms.
△ Less
Submitted 12 July, 2021; v1 submitted 23 November, 2020;
originally announced November 2020.
-
FCC-hh Experimental Insertion Region Design
Authors:
Jose L. Abelleira,
Robert B. Appleby,
Sergey Arsenyev,
Javier Barranco,
Michael Benedikt,
Maria Ilaria Besana,
Oscar Blanco Garcia,
Manuela Boscolo,
David Boutin,
Xavier Buffat,
Helmut Burkhardt,
Francesco Cerutti,
Antoine Chance,
Francesco Collamati,
Emilia Cruz-Alaniz,
Barbara Dalena,
Michael Hofer,
Barbara L. Humann,
Angelo Infantino,
Jacqueline Keintzel,
Andy Langner,
Marian Luckhof,
Roman Martin,
Tatiana Pieloni,
Haroon Rafique
, et al. (7 additional authors not shown)
Abstract:
The Future Circular Collider study is exploring possible designs of circular colliders for the post-LHC era, as recommended by the European Strategy Group for High Energy Physics. One such option is FCC-hh, a proton-proton collider with a centre-of-mass energy of 100 TeV. The experimental insertion regions are key areas defining the performance of the collider. This paper presents the first insert…
▽ More
The Future Circular Collider study is exploring possible designs of circular colliders for the post-LHC era, as recommended by the European Strategy Group for High Energy Physics. One such option is FCC-hh, a proton-proton collider with a centre-of-mass energy of 100 TeV. The experimental insertion regions are key areas defining the performance of the collider. This paper presents the first insertion region designs with a complete assessment of the main challenges, as collision debris with two orders of magnitude larger power than current colliders, beam-beam interactions in long insertions, dynamic aperture for optics with peak $β$ functions one order of magnitude above current colliders, photon background from synchrotron radiation and cross talk between the insertion regions. An alternative design avoiding the use of crab cavities with a small impact on performance is also presented.
△ Less
Submitted 23 July, 2020;
originally announced July 2020.
-
Report on the ECFA Early-Career Researchers Debate on the 2020 European Strategy Update for Particle Physics
Authors:
N. Andari,
L. Apolinário,
K. Augsten,
E. Bakos,
I. Bellafont,
L. Beresford,
A. Bethani,
J. Beyer,
L. Bianchini,
C. Bierlich,
B. Bilin,
K. L. Bjørke,
E. Bols,
P. A. Brás,
L. Brenner,
E. Brondolin,
P. Calvo,
B. Capdevila,
I. Cioara,
L. N. Cojocariu,
F. Collamati,
A. de Wit,
F. Dordei,
M. Dordevic,
T. A. du Pree
, et al. (96 additional authors not shown)
Abstract:
A group of Early-Career Researchers (ECRs) has been given a mandate from the European Committee for Future Accelerators (ECFA) to debate the topics of the current European Strategy Update (ESU) for Particle Physics and to summarise the outcome in a brief document [1]. A full-day debate with 180 delegates was held at CERN, followed by a survey collecting quantitative input. During the debate, the E…
▽ More
A group of Early-Career Researchers (ECRs) has been given a mandate from the European Committee for Future Accelerators (ECFA) to debate the topics of the current European Strategy Update (ESU) for Particle Physics and to summarise the outcome in a brief document [1]. A full-day debate with 180 delegates was held at CERN, followed by a survey collecting quantitative input. During the debate, the ECRs discussed future colliders in terms of the physics prospects, their implications for accelerator and detector technology as well as computing and software. The discussion was organised into several topic areas. From these areas two common themes were particularly highlighted by the ECRs: sociological and human aspects; and issues of the environmental impact and sustainability of our research.
△ Less
Submitted 7 February, 2020;
originally announced February 2020.
-
Detector and Physics Performance at a Muon Collider
Authors:
Nazar Bartosik,
Alessandro Bertolin,
Laura Buonincontri,
Massimo Casarsa,
Francesco Collamati,
Alfredo Ferrari,
Anna Ferrari,
Alessio Gianelle,
Donatella Lucchesi,
Nikolai Mokhov,
Mark Palmer,
Nadia Pastrone,
Paola Sala,
Lorenzo Sestini,
Sergei Striganov
Abstract:
A muon collider represents the ideal machine to reach very high center-of-mass energies and luminosities by colliding elementary particles. This is the result of the low level of beamstrahlung and synchrotron radiation compared to linear or circular electron-positron colliders. In contrast with other lepton machines, the design of a detector for a multi-TeV muon collider requires the knowledge of…
▽ More
A muon collider represents the ideal machine to reach very high center-of-mass energies and luminosities by colliding elementary particles. This is the result of the low level of beamstrahlung and synchrotron radiation compared to linear or circular electron-positron colliders. In contrast with other lepton machines, the design of a detector for a multi-TeV muon collider requires the knowledge of the interaction region due to the presence of a large amount of background induced by muon beam decays. The physics reaches can be properly evaluated only when the detector performance is determined. In this work, the background generated by muon beams of $750$ GeV is characterized and the performance of the tracking system and the calorimeter detector are illustrated. Solutions to minimize the effect of the beam-induced background are discussed and applied to obtain track and jet reconstruction performance. The $μ^+μ^-\to Hν\barν\to b\bar b ν\barν$ process is fully simulated and reconstructed to demonstrate that physics measurements are possible in this harsh environment. The precision on Higgs boson coupling to $b\bar b$ is evaluated for $\sqrt{s}=1.5$, 3, and 10 TeV and compared to other proposed machines.
△ Less
Submitted 29 January, 2020; v1 submitted 13 January, 2020;
originally announced January 2020.
-
Study of muon pair production from positron annihilation at threshold energy
Authors:
N. Amapane,
M. Antonelli,
F. Anulli,
G. Ballerini,
L. Bandiera,
N. Bartosik,
M. Bauce,
A. Bertolin,
C. Biino,
O. R. Blanco-Garcia,
M. Boscolo,
C. Brizzolari,
A. Cappati,
M. Casarsa,
G. Cavoto,
F. Collamati,
G. Cotto,
C. Curatolo,
R. Di Nardo,
F. Gonella,
S. Hoh,
M. Iafrati,
F. Iacoangeli,
B. Kiani,
D. Lucchesi
, et al. (17 additional authors not shown)
Abstract:
The muon collider represents one of the most promising solutions for a future machine exploring the high energy frontier, but several challenges due to the 2.2 $μ$sec muon lifetime at rest have to be carefully considered. The LEMMA project is investigating the possibility of producing low emittance muon/antimuon pairs from the e$^+$e$^-$ annihilation process at threshold energy, resulting in small…
▽ More
The muon collider represents one of the most promising solutions for a future machine exploring the high energy frontier, but several challenges due to the 2.2 $μ$sec muon lifetime at rest have to be carefully considered. The LEMMA project is investigating the possibility of producing low emittance muon/antimuon pairs from the e$^+$e$^-$ annihilation process at threshold energy, resulting in small transverse emittance beams without any additional beam cooling. However most of the measurements available are performed at higher $\sqrt{s}$ values. It is therefore necessary to measure muons production in positron annihilation at threshold energy and compare the experimental results with the predictions in this specific energy regime. Apart from being a topic of physical interest by itself, these near to threshold measurements can have a sizeable impact on the estimation of the ultimate luminosity achievable in a muon collider with the LEMMA injection scheme.
△ Less
Submitted 10 January, 2020; v1 submitted 30 September, 2019;
originally announced September 2019.
-
Positron driven muon source for a muon collider
Authors:
D. Alesini,
M. Antonelli,
M. E. Biagini,
M. Boscolo,
O. R. Blanco-García,
A. Ciarma,
R. Cimino,
M. Iafrati,
A. Giribono,
S. Guiducci,
L. Pellegrino,
M. Rotondo,
C. Vaccarezza,
A. Variola,
A. Allegrucci,
F. Anulli,
M. Bauce,
F. Collamati,
G. Cavoto,
G. Cesarini,
F. Iacoangeli,
R. Li Voti,
A. Bacci,
I. Drebot,
P. Raimondi
, et al. (33 additional authors not shown)
Abstract:
The design of a future multi-TeV muon collider needs new ideas to overcome the technological challenges related to muon production, cooling, accumulation and acceleration. In this paper a layout of a positron driven muon source known as the Low EMittance Muon Accelerator (LEMMA) concept is presented. The positron beam, stored in a ring with high energy acceptance and low emittance, is extracted an…
▽ More
The design of a future multi-TeV muon collider needs new ideas to overcome the technological challenges related to muon production, cooling, accumulation and acceleration. In this paper a layout of a positron driven muon source known as the Low EMittance Muon Accelerator (LEMMA) concept is presented. The positron beam, stored in a ring with high energy acceptance and low emittance, is extracted and driven to a multi-target system, to produce muon pairs at threshold. This solution alleviates the issues related to the power deposited and the integrated Peak Energy Density Deposition (PEDD) on the targets. Muons produced in the multi-target system will then be accumulated before acceleration and injection in the collider. A multi-target line lattice has been designed to cope with the focusing of both the positron and muon beams. Studies on the number, material and thickness of the targets have been carried out. A general layout of the overall scheme and a description is presented, as well as plans for future R&D.
△ Less
Submitted 19 May, 2019; v1 submitted 14 May, 2019;
originally announced May 2019.
-
Preliminary Report on the Study of Beam-Induced Background Effects at a Muon Collider
Authors:
Nazar Bartosik,
Alessandro Bertolin,
Massimo Casarsa,
Francesco Collamati,
Alfredo Ferrari,
Anna Ferrari,
Alessio Gianelle,
Donatella Lucchesi,
Nikolai Mokhov,
Stefan Mueller,
Nadia Pastrone,
Paola Sala,
Lorenzo Sestini,
Sergei Striganov
Abstract:
Physics at a multi-TeV muon collider needs a change of perspective for the detector design due to the large amount of background induced by muon beam decays. Preliminary studies, based on simulated data, on the composition and the characteristics of the particles originated from the muon decays and reaching the detectors are presented here. The reconstruction performance of the physics processes…
▽ More
Physics at a multi-TeV muon collider needs a change of perspective for the detector design due to the large amount of background induced by muon beam decays. Preliminary studies, based on simulated data, on the composition and the characteristics of the particles originated from the muon decays and reaching the detectors are presented here. The reconstruction performance of the physics processes $H\to b\bar b$ and $Z\to b\bar b$ has been investigated for the time being without the effect of the machine induced background. A preliminary study of the environment hazard due to the radiation induced by neutrino interactions with the matter is presented using the FLUKA simulation program.
△ Less
Submitted 9 May, 2019;
originally announced May 2019.
-
Machine detector interface for the $e^+e^-$ future circular collider
Authors:
Manuela Boscolo,
Oscar Blanco-Garcia,
Nicola Bacchetta,
Eleonora Belli,
Michael Benedikt,
Helmut Burkhardt,
Miguel Gil Costa,
Konrad Elsener,
Emilia Leogrande,
Patrick Janot,
Herman Ten Kate,
Dima El Khechen,
Anna Kolano,
Roberto Kersevan,
Marian Lueckof,
Katsunobu Oide,
Emmanuel Perez,
Nilou Teherani,
O. Viazlo,
Yorgos Voutsinas,
Frank Zimmermann,
Mogens Dam,
Alain Blondel,
M. Koratzinos,
Alexander Novokhatski
, et al. (5 additional authors not shown)
Abstract:
The international Future Circular Collider (FCC) study aims at a design of $pp$, $e^+e^-$, $ep$ colliders to be built in a new 100 km tunnel in the Geneva region. The $e^+e^-$ collider (FCC-ee) has a centre of mass energy range between 90 (Z-pole) and 375 GeV (tt_bar). To reach such unprecedented energies and luminosities, the design of the interaction region is crucial. The crab-waist collision s…
▽ More
The international Future Circular Collider (FCC) study aims at a design of $pp$, $e^+e^-$, $ep$ colliders to be built in a new 100 km tunnel in the Geneva region. The $e^+e^-$ collider (FCC-ee) has a centre of mass energy range between 90 (Z-pole) and 375 GeV (tt_bar). To reach such unprecedented energies and luminosities, the design of the interaction region is crucial. The crab-waist collision scheme has been chosen for the design and it will be compatible with all beam energies. In this paper we will describe the machine detector interface layout including the solenoid compensation scheme. We will describe how this layout fulfills all the requirements set by the parameters table and by the physical constraints. We will summarize the studies of the impact of the synchrotron radiation, the analysis of trapped modes and of the backgrounds induced by single beam and luminosity effects giving an estimate of the losses in the interaction region and in the detector.
△ Less
Submitted 9 May, 2019;
originally announced May 2019.
-
Low emittance muon accelerator studies with production from positrons on target
Authors:
M. Boscolo,
M. Antonelli,
O. R. Blanco-Garcia,
S. Guiducci,
S. Liuzzo,
P. Raimondi,
F. Collamati
Abstract:
A new scheme to produce very low emittance muon beams using a positron beam of about 45~GeV interacting on electrons on target is presented.
One of the innovative topics to be investigated is the behaviour of the positron beam stored in a low emittance ring with a thin target, that is directly inserted in the ring chamber to produce muons. Muons can be immediately collected at the exit of the ta…
▽ More
A new scheme to produce very low emittance muon beams using a positron beam of about 45~GeV interacting on electrons on target is presented.
One of the innovative topics to be investigated is the behaviour of the positron beam stored in a low emittance ring with a thin target, that is directly inserted in the ring chamber to produce muons. Muons can be immediately collected at the exit of the target and transported to two $μ^+$ and $μ^-$ accumulator rings and then accelerated and injected in muon collider rings. We focus in this paper on the simulation of the e$^+$ beam interacting with the target, the effect of the target on the 6-D phase space and the optimization of the e$^+$ ring design to maximize the energy acceptance. We will investigate the performance of this scheme, ring plus target system, comparing different multi-turn simulations. The source is considered for use in a multi-TeV collider in ref.[1]
△ Less
Submitted 11 June, 2018; v1 submitted 18 March, 2018;
originally announced March 2018.
-
Feasibility of the $β^-$ Radio-Guided Surgery with a Variety of Radio-Nuclides of Interest to Nuclear Medicine
Authors:
Carlo Mancini-Terracciano,
Raffaella Donnarumma,
Gaia Bencivenga,
Valerio Bocci,
Antonella Cartoni,
Francesco Collamati,
Ilaria Fratoddi,
Alessandro Giordano,
Luca Indovina,
Michela Marafini,
Silvio Morganti,
Dante Rotili,
Andrea Russomando,
Teresa Scotognella,
Elena Solfaroli Camillocci,
Marco Toppi,
Giacomo Traini,
Iole Venditti,
Riccardo Faccini
Abstract:
The $β^-$ based radio-guided surgery overcomes the corresponding $γ$ technique in case the background from healthy tissues is relevant. It can be used only in case a radio-tracer marked with $^{90}$Y is available since the current probe prototype was optimized for the emission spectrum of this radio-nuclide. Here we study, with a set of laboratory tests and simulations, the prototype capability in…
▽ More
The $β^-$ based radio-guided surgery overcomes the corresponding $γ$ technique in case the background from healthy tissues is relevant. It can be used only in case a radio-tracer marked with $^{90}$Y is available since the current probe prototype was optimized for the emission spectrum of this radio-nuclide. Here we study, with a set of laboratory tests and simulations, the prototype capability in case a different radio-nuclide is chosen among those used in nuclear medicine.
As a result we estimate the probe efficiency on electrons and photons as a function of energy and we evaluate the feasibility of a radio-guided surgery exploiting the selected radio-nuclides. We conclude that requiring a 0.1~ml residue to be detected within 1~s by administering 3~MBq/Kg of radio-isotope, the current probe prototype would yield a significant signal in a vast range of values of SUV and TNR in case $^{31}$Si,$^{32}$P, $^{97}$Zr, and $^{188}$Re are used. Conversely, a tuning of the detector would be needed to efficiency use $^{83}$Br, $^{133}$I, and $^{153}$Sm, although they could already be used in case of high SUV or TNR values. Finally, $^{18}$F,$^{67}$Cu, $^{131}$I, and $^{177}$Lu are not useable for radio-guided surgery with the current probe design.
△ Less
Submitted 28 October, 2016;
originally announced October 2016.
-
First Ex-Vivo Validation of a Radioguided Surgery Technique with beta- Radiation
Authors:
E. Solfaroli Camillocci,
M. Schiariti,
V. Bocci,
A. Carollo,
G. Chiodi,
M. Colandrea,
F. Collamati,
M. Cremonesi,
R. Donnarumma,
M. E. Ferrari,
P. Ferroli,
F. Ghielmetti,
C. M. Grana,
M. Marafini,
S. Morganti,
C. Mancini Terracciano,
M. Patanè,
G. Pedroli,
B. Pollo,
L. Recchia,
A. Russomando,
M. Toppi,
G. Traini,
R. Faccini
Abstract:
Purpose: A radio-guided surgery technique with beta- -emitting radio-tracers was suggested to overcome the effect of the large penetration of gamma radiation. The feasibility studies in the case of brain tumors and abdominal neuro-endocrine tumors were based on simulations starting from PET images with several underlying assumptions. This paper reports, as proof-of-principle of this technique, an…
▽ More
Purpose: A radio-guided surgery technique with beta- -emitting radio-tracers was suggested to overcome the effect of the large penetration of gamma radiation. The feasibility studies in the case of brain tumors and abdominal neuro-endocrine tumors were based on simulations starting from PET images with several underlying assumptions. This paper reports, as proof-of-principle of this technique, an ex-vivo test on a meningioma patient. This test allowed to validate the whole chain, from the evaluation of the SUV of the tumor, to the assumptions on the bio-distribution and the signal detection.
Methods: A patient affected by meningioma was administered 300 MBq of 90Y-DOTATOC. Several samples extracted from the meningioma and the nearby Dura Mater were analyzed with a beta- probe designed specifically for this radio-guided surgery technique. The observed signals were compared both with the evaluation from the histology and with the Monte Carlo simulation.
Results: we obtained a large signal on the bulk tumor (105 cps) and a significant signal on residuals of $\sim$0.2 ml (28 cps). We also show that simulations predict correctly the observed yields and this allows us to estimate that the healthy tissues would return negligible signals (~1 cps). This test also demonstrated that the exposure of the medical staff is negligible and that among the biological wastes only urine has a significant activity.
Conclusions: This proof-of-principle test on a patient assessed that the technique is feasible with negligible background to medical personnel and confirmed that the expectations obtained with Monte Carlo simulations starting from diagnostic PET images are correct.
△ Less
Submitted 30 August, 2016;
originally announced August 2016.
-
Secondary radiation measurements for particle therapy applications: nuclear fragmentation produced by $^4$He ion beams in a PMMA target
Authors:
M. Marafini,
R. Paramatti,
D. Pinci,
G. Battistoni,
F. Collamati,
E. De Lucia,
R. Faccini,
P. M. Frallicciardi,
C. Mancini-Terracciano,
I. Mattei,
S. Muraro,
L. Piersanti,
M. Rovituso,
A. Rucinski,
A. Russomando,
A. Sarti,
A. Sciubba,
E. Solfaroli Camillocci,
M. Toppi,
G. Traini,
C. Voena,
V. Patera
Abstract:
Nowadays there is a growing interest in Particle Therapy treatments exploiting light ion beams against tumors due to their enhanced Relative Biological Effectiveness and high space selectivity. In particular promising results are obtained by the use of $^4$He projectiles. Unlike the treatments performed using protons, the beam ions can undergo a fragmentation process when interacting with the atom…
▽ More
Nowadays there is a growing interest in Particle Therapy treatments exploiting light ion beams against tumors due to their enhanced Relative Biological Effectiveness and high space selectivity. In particular promising results are obtained by the use of $^4$He projectiles. Unlike the treatments performed using protons, the beam ions can undergo a fragmentation process when interacting with the atomic nuclei in the patient body. In this paper the results of measurements performed at the Heidelberg Ion-Beam Therapy center are reported. For the first time the absolute fluxes and the energy spectra of the fragments - protons, deuterons, and tritons - produced by $^4$He ion beams of 102, 125 and 145 MeV/u energies on a poly-methyl methacrylate target were evaluated at different angles. The obtained results are particularly relevant in view of the necessary optimization and review of the Treatment Planning Software being developed for clinical use of $^4$He beams in clinical routine and the relative benchmarking of Monte Carlo algorithm predictions.
△ Less
Submitted 29 August, 2016;
originally announced August 2016.
-
Secondary radiation measurements for particle therapy applications: Charged secondaries produced by 4He and 12C ion beams in a PMMA target at large angle
Authors:
A. Rucinski,
E. De Lucia,
G. Battistoni,
F. Collamati,
R. Faccini,
P. M. Frallicciardi,
C. Mancini-Terracciano,
M. Marafini,
I. Mattei,
S. Muraro,
R. Paramatti,
L. Piersanti,
D. Pinci,
A. Russomando,
A. Sarti,
A. Sciubba,
E. Solfaroli Camillocci,
M. Toppi,
G. Traini,
C. Voena,
V. Patera
Abstract:
Measurements performed with the purpose of characterizing the charged secondary radiation for dose release monitoring in particle therapy are reported. Charged secondary yields, energy spectra and emission profiles produced in poly-methyl methacrylate (PMMA) target by 4He and 12C beams of different therapeutic energies were measured at 60 and 90 degree with respect to the primary beam direction. T…
▽ More
Measurements performed with the purpose of characterizing the charged secondary radiation for dose release monitoring in particle therapy are reported. Charged secondary yields, energy spectra and emission profiles produced in poly-methyl methacrylate (PMMA) target by 4He and 12C beams of different therapeutic energies were measured at 60 and 90 degree with respect to the primary beam direction. The secondary yields of protons produced along the primary beam path in PMMA target were obtained. The energy spectra of charged secondaries were obtained from time-of-flight information, whereas the emission profiles were reconstructed exploiting tracking detector information. The measured charged secondary yields and emission profiles are in agreement with the results reported in literature and confirm the feasibility of ion beam therapy range monitoring using 12C ion beam. The feasibility of range monitoring using charged secondary particles is also suggested for 4He ion beam.
△ Less
Submitted 16 August, 2016;
originally announced August 2016.
-
Design of a new tracking device for on-line dose monitor in ion therapy
Authors:
Giacomo Traini,
Giuseppe Battistoni,
Angela Bollella,
Francesco Collamati,
Erika De Lucia,
Riccardo Faccini,
Fernando Ferroni,
Paola Maria Frallicciardi,
Carlo Mancini-Terracciano,
Michela Marafini,
Ilaria Mattei,
Federico Miraglia,
Silvia Muraro,
Riccardo Paramatti,
Luca Piersanti,
Davide Pinci,
Antoni Rucinski,
Andrea Russomando,
Alessio Sarti,
Adalberto Sciubba,
Martina Senzacqua,
Elena Solfaroli-Camillocci,
Marco Toppi,
Cecilia Voena,
Vincenzo Patera
Abstract:
Charged Particle Therapy is a technique for cancer treatment that exploits hadron beams, mostly protons and carbons. A critical issue is the monitoring of the dose released by the beam to the tumor and to the surrounding tissues. We present the design of a new tracking device for monitoring on-line the dose in ion therapy through the detection of secondary charged particles produced by the beam in…
▽ More
Charged Particle Therapy is a technique for cancer treatment that exploits hadron beams, mostly protons and carbons. A critical issue is the monitoring of the dose released by the beam to the tumor and to the surrounding tissues. We present the design of a new tracking device for monitoring on-line the dose in ion therapy through the detection of secondary charged particles produced by the beam interactions in the patient tissues. In fact, the charged particle emission shape can be correlated with the spatial dose release and the Bragg peak position. The detector uses the information provided by 12 layers of scintillating fibers followed by a plastic scintillator and a small calorimeter made of a pixelated Lutetium Fine Silicate crystal. Simulations have been performed to evaluate the achievable spatial resolution and a possible application of the device for the monitoring of the dose profile in a real treatment is presented.
△ Less
Submitted 28 July, 2016;
originally announced July 2016.
-
Secondary radiation measurements for particle therapy applications: prompt photons produced by $^{4}$He, $^{12}$C and $^{16}$O ion beams in a PMMA target
Authors:
Ilaria Mattei,
Francesco Collamati,
Erika De Lucia,
Riccardo Faccini,
Paola Maria Frallicciardi,
Carlo Mancini-Terracciano,
Michela Marafini,
Silvia Muraro,
Riccardo Paramatti,
Vincenzo Patera,
Luca Piersanti,
Davide Pinci,
Antoni Rucinski,
Andrea Russomando,
Alessio Sarti,
Adalberto Sciubba,
Elena Solfaroli Camillocci,
Marco Toppi,
Giacomo Traini,
Cecilia Voena,
Giuseppe Battistoni
Abstract:
Charged particle beams are used in Particle Therapy (PT) to treat oncological patients due to their selective dose deposition in tissues and to their high biological effect in killing cancer cells with respect to photons and electrons used in conventional radiotherapy. Nowadays, protons and carbon ions are used in PT clinical routine but, recently, the interest on the potential application of heli…
▽ More
Charged particle beams are used in Particle Therapy (PT) to treat oncological patients due to their selective dose deposition in tissues and to their high biological effect in killing cancer cells with respect to photons and electrons used in conventional radiotherapy. Nowadays, protons and carbon ions are used in PT clinical routine but, recently, the interest on the potential application of helium and oxygen beams is growing due to their reduced multiple scattering inside the body and increased linear energy transfer, relative biological effectiveness and oxygen enhancement ratio. The precision of PT demands for online dose monitoring techniques, crucial to improve the quality assurance of treatments. The beam range confined in the irradiated target can be monitored thanks to the neutral or charged secondary radiation emitted by the interactions of hadron beams with matter. Prompt photons are produced by nuclear de-excitation processes and, at present, different dose monitoring and beam range verification techniques based on the prompt γ detection have been proposed. It is hence of importance to perform the γ yield measurement in therapeutical-like conditions. In this paper we report the yields of prompt photons produced by the interaction of helium, carbon and oxygen ion beams with a PMMA target. The measurements were performed at the Heidelberg Ion-beam Therapy center (HIT) with beams of different energies. A LYSO scintillator has been used as photon detector. The obtained γ yields for $^{12}$C ion beams are compared with results from literature, while no other results from $^{4}$He and $^{16}$O beams have been published yet. A discussion on the expected resolution of a slit camera detector is presented, demonstrating the feasibility of a prompt-γ based monitoring technique for PT treatments using helium, carbon and oxygen ion beams.
△ Less
Submitted 19 July, 2016; v1 submitted 26 May, 2016;
originally announced May 2016.
-
Polycrystalline para-terphenyl scintillator adopted in a $β^-$ detecting probe for radio-guided surgery
Authors:
Elena Solfaroli Camillocci,
Fabio Bellini,
Valerio Bocci,
Francesco Collamati,
Erika De Lucia,
Riccardo Faccini,
Michela Marafini,
Ilaria Mattei,
Silvio Morganti,
Riccardo Paramatti,
Vincenzo Patera,
Davide Pinci,
Luigi Recchia,
Andrea Russomando,
Alessio Sarti,
Adalberto Sciubba,
Martina Senzacqua,
Cecilia Voena
Abstract:
A radio-guided surgery technique exploiting $β^-$ emitters is under development. It aims at a higher target-to-background activity ratio implying both a smaller radiopharmaceutical activity and the possibility of extending the technique to cases with a large uptake of surrounding healthy organs. Such technique requires a dedicated intraoperative probe detecting $β^-$ radiation. A first prototype h…
▽ More
A radio-guided surgery technique exploiting $β^-$ emitters is under development. It aims at a higher target-to-background activity ratio implying both a smaller radiopharmaceutical activity and the possibility of extending the technique to cases with a large uptake of surrounding healthy organs. Such technique requires a dedicated intraoperative probe detecting $β^-$ radiation. A first prototype has been developed relying on the low density and high light yield of the diphenylbutadiene doped para-therphenyl organic scintillator. The scintillation light produced in a cylindrical crystal, 5 mm in diameter and 3 mm in height, is guided to a photo-multiplier tube by optical fibres. The custom readout electronics is designed to optimize its usage in terms of feedback to the surgeon, portability and remote monitoring of the signal. Tests show that with a radiotracer activity comparable to those administered for diagnostic purposes the developed probe can detect a 0.1 ml cancerous residual of meningioma in a few seconds.
△ Less
Submitted 9 November, 2015;
originally announced November 2015.
-
An Intraoperative $β^-$ Detecting Probe For Radio-Guided Surgery in Tumour Resection
Authors:
Andrea Russomando,
Fabio Bellini,
Valerio Bocci,
Giacomo Chiodi,
Francesco Collamati,
Erika De Lucia,
Raffaella Donnarumma,
Riccardo Faccini,
Carlo Mancini Terracciano,
Michela Marafini,
Riccardo Paramatti,
Vincenzo Patera,
%Davide Pinci,
Luigi Recchia,
Alessio Sarti,
Adalberto Sciubba,
Elena Solfaroli Camillocci,
Cecilia Voena,
Silvio Morganti
Abstract:
The development of the $β^-$ based radio-guided surgery aims to extend the technique to those tumours where surgery is the only possible treatment and the assessment of the resection would most profit from the low background around the lesion, as for brain tumours. Feasibility studies on meningioma, glioma, and neuroendocrine tumors already estimated the potentiality of this new treatment. To vali…
▽ More
The development of the $β^-$ based radio-guided surgery aims to extend the technique to those tumours where surgery is the only possible treatment and the assessment of the resection would most profit from the low background around the lesion, as for brain tumours. Feasibility studies on meningioma, glioma, and neuroendocrine tumors already estimated the potentiality of this new treatment. To validate the technique, prototypes of the intraoperative probe required by the technique to detect $β^-$ radiation have been developed. This paper discusses the design details of the device and the tests performed in laboratory. In such tests particular care has to be taken to reproduce the surgical field conditions. The innovative technique to produce specific phantoms and the dedicated testing protocols is described in detail.
△ Less
Submitted 6 November, 2015;
originally announced November 2015.
-
Towards a Radio-guided Surgery with $β^{-}$ Decays: Uptake of a somatostatin analogue (DOTATOC) in Meningioma and High Grade Glioma
Authors:
Francesco Collamati,
Alessandra Pepe,
Fabio Bellini,
Valerio Bocci,
Marta Cremonesi,
Erika De Lucia,
Mahila Ferrari,
Paola M. Frallicciardi,
Chiara M. Grana,
Michela Marafini,
Ilaria Mattei,
Silvio Morganti,
Vincenzo Patera,
Luca Piersanti,
Luigi Recchia,
Andrea Russomando,
Alessio Sarti,
Adalberto Sciubba,
Martina Senzacqua,
Elena Solfaroli Camillocci,
Cecilia Voena,
Riccardo Faccini
Abstract:
A novel radio guided surgery (RGS) technique for cerebral tumors using $β^{-}$ radiation is being developed. Checking the availability of a radio-tracer that can deliver a $β^{-}$ emitter to the tumor is a fundamental step in the deployment of such technique. This paper reports a study of the uptake of 90Y labeled (DOTATOC) in the meningioma and the high grade glioma (HGG) and a feasibility study…
▽ More
A novel radio guided surgery (RGS) technique for cerebral tumors using $β^{-}$ radiation is being developed. Checking the availability of a radio-tracer that can deliver a $β^{-}$ emitter to the tumor is a fundamental step in the deployment of such technique. This paper reports a study of the uptake of 90Y labeled (DOTATOC) in the meningioma and the high grade glioma (HGG) and a feasibility study of the RGS technique in these cases.
△ Less
Submitted 23 December, 2014;
originally announced December 2014.
-
A novel radioguided surgery technique exploiting $β^{-}$ decays
Authors:
E. Solfaroli Camillocci,
G. Baroni,
F. Bellini,
V. Bocci,
F. Collamati,
M. Cremonesi,
E. De Lucia,
P. Ferroli,
S. Fiore,
C. M. Grana,
M. Marafini,
I. Mattei,
S. Morganti,
G. Paganelli,
V. Patera,
L. Piersanti,
L. Recchia,
A. Russomando,
M. Schiariti,
A. Sarti,
A. Sciubba,
C. Voena,
R. Faccini
Abstract:
The background induced by the high penetration power of the gamma radiation is the main limiting factor of the current Radio-guided surgery (RGS). To partially mitigate it, a RGS with beta+ emitting radio-tracers has been suggested in literature.
Here we propose the use of beta- emitting radio-tracers and beta- probes and discuss the advantage of this method with respect to the previously explor…
▽ More
The background induced by the high penetration power of the gamma radiation is the main limiting factor of the current Radio-guided surgery (RGS). To partially mitigate it, a RGS with beta+ emitting radio-tracers has been suggested in literature.
Here we propose the use of beta- emitting radio-tracers and beta- probes and discuss the advantage of this method with respect to the previously explored ones: the electron low penetration power allows for simple and versatile probes and could extend RGS to tumours for which background originating from nearby healthy tissue makes gamma probes less effective. We developed a beta- probe prototype and studied its performances on phantoms. By means of a detailed simulation we have also extrapolated the results to estimate the performances in a realistic case of meningioma, pathology which is going to be our first in-vivo test case. A good sensitivity to residuals down to 0.1ml can be reached within 1s with an administered activity smaller than those for PET-scans thus making the radiation exposure to medical personnel negligible.
△ Less
Submitted 10 February, 2014;
originally announced February 2014.
-
Extended calibration range for prompt photon emission in ion beam irradiation
Authors:
F. Bellini,
T. T. Boehlen,
M. P. W. Chin,
F. Collamati,
E. De Lucia,
R. Faccini,
A. Ferrari,
L. Lanza,
C. Mancini-Terraciano,
M. Marafini,
I. Mattei,
S. Morganti,
P. G. Ortega,
V. Patera,
L. Piersanti,
A. Russomando,
P. R. Sala,
A. Sarti,
A. Sciubba,
E. Solfaroli Camillocci,
C. Voena
Abstract:
Monitoring the dose delivered during proton and carbon ion therapy is still a matter of research. Among the possible solutions, several exploit the measurement of the single photon emission from nuclear decays induced by the irradiation. To fully characterize such emission the detectors need development, since the energy spectrum spans the range above the MeV that is not traditionally used in medi…
▽ More
Monitoring the dose delivered during proton and carbon ion therapy is still a matter of research. Among the possible solutions, several exploit the measurement of the single photon emission from nuclear decays induced by the irradiation. To fully characterize such emission the detectors need development, since the energy spectrum spans the range above the MeV that is not traditionally used in medical applications. On the other hand, a deeper understanding of the reactions involving gamma production is needed in order to improve the physic models of Monte Carlo codes, relevant for an accurate prediction of the prompt-gamma energy spectrum.This paper describes a calibration technique tailored for the range of energy of interest and reanalyzes the data of the interaction of a 80MeV/u fully stripped carbon ion beam with a Poly-methyl methacrylate target. By adopting the FLUKA simulation with the appropriate calibration and resolution a significant improvement in the agreement between data and simulation is reported.
△ Less
Submitted 22 July, 2013;
originally announced July 2013.
-
Properties of para-terphenyl as detector for alpha, beta and gamma radiation
Authors:
M. Angelone,
G. Battistoni,
F. Bellini,
V. Bocci,
F. Collamati,
E. De Lucia,
R. Faccini,
F. Ferroni,
S. Fiore,
M. Marafini,
D. Materazzo,
I. Mattei,
S. Morganti,
V. Patera,
L. Piersanti,
M. Pillon,
L. Recchia,
A. Russomando,
A. Sarti,
A. Sciubba,
E. Solfaroli Camillocci,
C. Voena
Abstract:
Organic scintillators are often chosen as radiation detectors for their fast decay time and their low Z, while inorganic ones are used when high light ields are required. In this paper we show that a para-terphenyl based detector has a blend of properties of the two categories that can be optimal for energy and position measurements of low energy charged particles. On 0.1% diphenylbutadiene doped…
▽ More
Organic scintillators are often chosen as radiation detectors for their fast decay time and their low Z, while inorganic ones are used when high light ields are required. In this paper we show that a para-terphenyl based detector has a blend of properties of the two categories that can be optimal for energy and position measurements of low energy charged particles. On 0.1% diphenylbutadiene doped para-terphenyl samples we measure a light yield 3.5+-0.2 times larger than a typical organic scintillator (EJ-200), and a rejection power for 660 keV photons, with respect to electrons of the same energy, ranging between 3-11%, depending on the signal threshold. We also measure a light attenuation length = 4.73+-0.06 mm and we demonstrate that, with the measurements performed in this paper, a simulation based on FLUKA can properly reproduce the measured spectra.
△ Less
Submitted 2 May, 2013;
originally announced May 2013.
-
Charged particle's flux measurement from PMMA irradiated by 80 MeV/u carbon ion beam
Authors:
C. Agodi,
G. Battistoni,
F. Bellini,
G. A. P. Cirrone,
F. Collamati,
G. Cuttone,
E. De Lucia,
M. De Napoli,
A. Di Domenico,
R. Faccini,
F. Ferroni,
S. Fiore,
P. Gauzzi,
E. Iarocci,
M. Marafini,
I. Mattei,
S. Muraro,
A. Paoloni,
V. Patera,
L. Piersanti,
F. Romano,
A. Sarti,
A. Sciubba,
E. Vitale,
C. Voena
Abstract:
Hadrontherapy is an emerging technique in cancer therapy that uses beams of charged particles. To meet the improved capability of hadrontherapy in matching the dose release with the cancer position, new dose monitoring techniques need to be developed and introduced into clinical use. The measurement of the fluxes of the secondary particles produced by the hadron beam is of fundamental importance i…
▽ More
Hadrontherapy is an emerging technique in cancer therapy that uses beams of charged particles. To meet the improved capability of hadrontherapy in matching the dose release with the cancer position, new dose monitoring techniques need to be developed and introduced into clinical use. The measurement of the fluxes of the secondary particles produced by the hadron beam is of fundamental importance in the design of any dose monitoring device and is eagerly needed to tune Monte Carlo simulations. We report the measurements done with charged secondary particles produced from the interaction of a 80 MeV/u fully stripped carbon ion beam at the INFN Laboratori Nazionali del Sud, Catania, with a Poly-methyl methacrylate target. Charged secondary particles, produced at 90$\degree$ with respect to the beam axis, have been tracked with a drift chamber, while their energy and time of flight has been measured by means of a LYSO scintillator. Secondary protons have been identified exploiting the energy and time of flight information, and their emission region has been reconstructed backtracking from the drift chamber to the target. Moreover a position scan of the target indicates that the reconstructed emission region follows the movement of the expected Bragg peak position. Exploting the reconstruction of the emission region, an accuracy on the Bragg peak determination in the submillimeter range has been obtained. The measured differential production rate for protons produced with $E^{\rm Prod}_{\rm kin} >$ 83 MeV and emitted at 90$\degree$ with respect to the beam line is: $dN_{\rm P}/(dN_{\rm C}dΩ)(E^{\rm Prod}_{\rm kin} > 83 {\rm ~MeV}, θ=90\degree)= (2.69\pm 0.08_{\rm stat} \pm 0.12_{\rm sys})\times 10^{-4} sr^{-1}$.
△ Less
Submitted 21 March, 2012;
originally announced March 2012.
-
Study of the time and space distribution of beta+ emitters from 80 MeV/u carbon ion beam irradiation on PMMA
Authors:
C. Agodi,
F. Bellini,
G. A. P. Cirrone,
F. Collamati,
G. Cuttone,
E. De Lucia,
M. De Napoli,
A. Di Domenico,
R. Faccini,
F. Ferroni,
S. Fiore,
P. Gauzzi,
E. Iarocci,
M. Marafini,
I. Mattei,
A. Paoloni,
V. Patera,
L. Piersanti,
F. Romano,
A. Sarti,
A. Sciubba,
C. Voena
Abstract:
Proton and carbon ion therapy is an emerging technique used for the treatment of solid cancers. The monitoring of the dose delivered during such treatments and the on-line knowledge of the Bragg peak position is still a matter of research. A possible technique exploits the collinear $511\ \kilo\electronvolt$ photons produced by positrons annihilation from $β^+$ emitters created by the beam. This p…
▽ More
Proton and carbon ion therapy is an emerging technique used for the treatment of solid cancers. The monitoring of the dose delivered during such treatments and the on-line knowledge of the Bragg peak position is still a matter of research. A possible technique exploits the collinear $511\ \kilo\electronvolt$ photons produced by positrons annihilation from $β^+$ emitters created by the beam. This paper reports rate measurements of the $511\ \kilo\electronvolt$ photons emitted after the interactions of a $80\ \mega\electronvolt / u$ fully stripped carbon ion beam at the Laboratori Nazionali del Sud (LNS) of INFN, with a Poly-methyl methacrylate target. The time evolution of the $β^+$ rate was parametrized and the dominance of $^{11}C$ emitters over the other species ($^{13}N$, $^{15}O$, $^{14}O$) was observed, measuring the fraction of carbon ions activating $β^+$ emitters $A_0=(10.3\pm0.7)\cdot10^{-3}$. The average depth in the PMMA of the positron annihilation from $β^+$ emitters was also measured, $D_{β^+}=5.3\pm1.1\ \milli\meter$, to be compared to the expected Bragg peak depth $D_{Bragg}=11.0\pm 0.5\ \milli\meter$ obtained from simulations.
△ Less
Submitted 27 April, 2012; v1 submitted 8 February, 2012;
originally announced February 2012.
-
Precise measurement of prompt photon emission for carbon ion therapy
Authors:
C. Agodi,
F. Bellini,
G. A. P. Cirrone,
F. Collamati,
G. Cuttone,
E. De Lucia,
M. De Napoli,
A. Di Domenico,
R. Faccini,
F. Ferroni,
S. Fiore,
P. Gauzzi,
E. Iarocci,
M. Marafini,
I. Mattei,
A. Paoloni,
V. Patera,
L. Piersanti,
F. Romano,
A. Sarti,
A. Sciubba,
C. Voena
Abstract:
Proton and carbon ion therapy is an emerging technique used for the treatment of solid cancers. The monitoring of the dose delivered during such treatments is still a matter of research. A possible technique exploits the information provided by single photon emission from nuclear decays induced by the irradiation. This paper reports the measurements of the spectrum and rate of such photons produce…
▽ More
Proton and carbon ion therapy is an emerging technique used for the treatment of solid cancers. The monitoring of the dose delivered during such treatments is still a matter of research. A possible technique exploits the information provided by single photon emission from nuclear decays induced by the irradiation. This paper reports the measurements of the spectrum and rate of such photons produced from the interaction of a 80 MeV/u fully stripped carbon ion beam at the Laboratori Nazionali del Sud of INFN, Catania, with a Poly-methyl methacrylate target. The differential production rate for photons with energy E > 2 MeV and emitted at 90 degree is found to be $dN_γ/(dN_C dΩ)=(2.92\pm 0.19)\times 10^{-2}$sr$^{-1}$.
△ Less
Submitted 17 October, 2011;
originally announced October 2011.