Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content

Showing 1–17 of 17 results for author: Helaine, V

.
  1. arXiv:2001.11966  [pdf, other

    hep-ex nucl-ex physics.ins-det

    Measurement of the permanent electric dipole moment of the neutron

    Authors: C. Abel, S. Afach, N. J. Ayres, C. A. Baker, G. Ban, G. Bison, K. Bodek, V. Bondar, M. Burghoff, E. Chanel, Z. Chowdhuri, P. -J. Chiu, B. Clement, C. B. Crawford, M. Daum, S. Emmenegger, L. Ferraris-Bouchez, M. Fertl, P. Flaux, B. Franke, A. Fratangelo, P. Geltenbort, K. Green, W. C. Griffith, M. van der Grinten , et al. (59 additional authors not shown)

    Abstract: We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons (UCN). Our measurement stands in the long history of EDM experiments probing physics violating time reversal invariance. The salient features of this experiment were the use of a Hg-19… ▽ More

    Submitted 31 January, 2020; originally announced January 2020.

    Comments: 5 pages, 4 figures, submitted to PRL on 18.12.2019

    Journal ref: Phys. Rev. Lett. 124, 081803 (2020)

  2. arXiv:1912.04631  [pdf, other

    physics.atom-ph hep-ex nucl-ex

    Optically Pumped Cs Magnetometers Enabling a High-Sensitivity Search for the Neutron Electric Dipole Moment

    Authors: C. Abel, S. Afach, N. J. Ayres, G. Ban, G. Bison, K. Bodek, V. Bondar, E. Chanel, P. -J. Chiu, C. B. Crawford, Z. Chowdhuri, M. Daum, S. Emmenegger, L. Ferraris-Bouchez, M. Fertl, B. Franke, W. C. Griffith, Z. D. Grujić, L. Hayen, V. Hélaine, N. Hild, M. Kasprzak, Y. Kermaidic, K. Kirch, P. Knowles , et al. (35 additional authors not shown)

    Abstract: An array of sixteen laser-pumped scalar Cs magnetometers was part of the neutron electric dipole moment (nEDM) experiment taking data at the Paul Scherrer Institute in 2015 and 2016. It was deployed to measure the gradients of the experiment's magnetic field and to monitor their temporal evolution. The originality of the array lies in its compact design, in which a single near-infrared diode laser… ▽ More

    Submitted 28 April, 2020; v1 submitted 10 December, 2019; originally announced December 2019.

    Journal ref: Phys. Rev. A 101, 053419 (2020)

  3. Sterile Neutrino Constraints from the STEREO Experiment with 66 days of Reactor-on Data

    Authors: H. Almazán, P. del Amo Sanchez, L. Bernard, A. Blanchet, A. Bonhomme, C. Buck, J. Favier, J. Haser, V. Hélaine, F. Kandzia, S. Kox, J. Lamblin, A. Letourneau, D. Lhuillier, M. Lindner, L. Manzanillas, T. Materna, A. Minotti, F. Montanet, H. Pessard, J. -S. Real, C. Roca, T. Salagnac, S. Schoppmann, V. Sergeyeva , et al. (3 additional authors not shown)

    Abstract: The reactor antineutrino anomaly might be explained by the oscillation of reactor antineutrinos toward a sterile neutrino of eV mass. In order to explore this hypothesis, the STEREO experiment measures the antineutrino energy spectrum in six different detector cells covering baselines between 9 and 11 m from the compact core of the ILL research reactor. In this Letter, results from 66 days of reac… ▽ More

    Submitted 18 October, 2018; v1 submitted 6 June, 2018; originally announced June 2018.

    Journal ref: Phys. Rev. Lett. 121, 161801 (2018)

  4. arXiv:1804.09052  [pdf, other

    physics.ins-det hep-ex

    The STEREO Experiment

    Authors: N. Allemandou, H. Almazán, P. del Amo Sanchez, L. Bernard, C. Bernard, A. Blanchet, A. Bonhomme, G. Bosson, O. Bourrion, J. Bouvier, C. Buck, V. Caillot, M. Chala, P. Champion, P. Charon, A. Collin, P. Contrepois, G. Coulloux, B. Desbrières, G. Deleglise, W. El Kanawati, J. Favier, S. Fuard, I. Gomes Monteiro, B. Gramlich , et al. (40 additional authors not shown)

    Abstract: The STEREO experiment is a very short baseline reactor antineutrino experiment aiming at testing the hypothesis of light sterile neutrinos as an explanation of the deficit of the observed neutrino interaction rate with respect to the predicted rate, known as the Reactor Antineutrino Anomaly. The detector center is located 10 m away from the compact, highly $^{235}$U enriched core of the research n… ▽ More

    Submitted 14 August, 2018; v1 submitted 24 April, 2018; originally announced April 2018.

    Comments: 32 pages, 17 figures

    Journal ref: Journal of Instrumentation 13, 07 (2018): P07009

  5. arXiv:1610.00003  [pdf, other

    physics.ins-det hep-ex

    Electronics for the STEREO experiment

    Authors: V. Hélaine, STEREO collaboration

    Abstract: The STEREO experiment, aiming to probe short baseline neutrino oscillations by precisely measuring reactor anti-neutrino spectrum, is currently under installation. It is located at short distance from the compact research reactor core of the Institut Laue-Langevin, Grenoble, France. Dedicated electronics, hosted in a single $μ$TCA crate, were designed for this experiment. In this article, the elec… ▽ More

    Submitted 30 September, 2016; originally announced October 2016.

    Comments: Neutrino2016 conference proceedings, 3 pages

  6. arXiv:1606.07432  [pdf, other

    physics.ins-det nucl-ex

    Ultracold neutron detection with 6Li-doped glass scintillators, NANOSC: a fast ultracold neutron detector for the nEDM experiment at the Paul Scherrer Institute

    Authors: G. Ban, G. Bison, K. Bodek, Z. Chowdhuri, P. Geltenbort, W. C. Griffith, V. Hélaine, R. Henneck, M. Kasprzak, Y. Kermaidic, K. Kirch, S. Komposch, P. A. Koss, A. Kozela, J. Krempel, B. Lauss, T. Lefort, Y. Lemière, A. Mtchedlishvili, M. Musgrave, O. Naviliat-Cuncic, F. M. Piegsa, E. Pierre, G. Pignol, G. Quéméner , et al. (10 additional authors not shown)

    Abstract: This paper summarizes the results from measurements aiming to characterize ultracold neutron detection with 6Li-doped glass scintillators. Single GS10 or GS20 scintillators, with a thickness of 100-200 micrometer, fulfill the ultracold neutron detection requirements with an acceptable neutron-gamma discrimination. This discrimination is clearly improved with a stack of two scintillators: a 6Li-dep… ▽ More

    Submitted 23 June, 2016; originally announced June 2016.

    Comments: 14 pages, 12 figures, regular article submitted for publication

    ACM Class: J.2

  7. arXiv:1604.08877  [pdf, ps, other

    physics.ins-det hep-ex

    Sterile neutrino search at the ILL nuclear reactor: the STEREO experiment

    Authors: V. Hélaine

    Abstract: Search for a light sterile neutrino is currently a hot topic of neutrino physics, arising from the so-called gallium and reactor anomalies, in which a deficit of neutrinos was observed with respect to expectations. Such anomalies could be explained by short distance oscillations towards a sterile state, with $Δ\mathrm{m}^2\sim$1\,eV$^2$. The STEREO detector has been designed to track the electron… ▽ More

    Submitted 2 May, 2016; v1 submitted 29 April, 2016; originally announced April 2016.

    Comments: Talk presented at NuPhys2015 (London, 16-18 December 2015). 4 pages, LaTeX, 2 eps figures

    Report number: NuPhys2015-Helaine

  8. Trigger and readout electronics for the STEREO experiment

    Authors: O. Bourrion, J. L. Bouly, J. Bouvier, G. Bosson, V. Helaine, J. Lamblin, C. Li, F. Montanet, J. S. Real, T. Salagnac, N. Ponchant, A. Stutz, D. Tourres, C. Vescovi, S. Zsoldos

    Abstract: The STEREO experiment will search for a sterile neutrino by measuring the anti-neutrino energy spectrum as a function of the distance from the source, the ILL nuclear reactor. A dedicated electronic system, hosted in a single microTCA crate, was designed for this experiment. It performs triggering in two stages with various selectable conditions, processing and readout via UDP/IPBUS of 68 photomul… ▽ More

    Submitted 18 January, 2016; v1 submitted 28 October, 2015; originally announced October 2015.

    Comments: Topical Workshop on Electronics for Particle Physics (TWEPP) 2015, Lisboa. 9 pages, 9 figures

    Journal ref: JINST 11 C02078 (2016)

  9. arXiv:1509.04411  [pdf, other

    hep-ex physics.ins-det

    A Revised Experimental Upper Limit on the Electric Dipole Moment of the Neutron

    Authors: J. M. Pendlebury, S. Afach, N. J. Ayres, C. A. Baker, G. Ban, G. Bison, K. Bodek, M. Burghoff, P. Geltenbort, K. Green, W. C. Griffith, M. van der Grinten, Z. D. Grujic, P. G. Harris, V. Helaine, P. Iaydjiev, S. N. Ivanov, M. Kasprzak, Y. Kermaidic, K. Kirch, H. -C. Koch, S. Komposch, A. Kozela, J. Krempel, B. Lauss , et al. (25 additional authors not shown)

    Abstract: We present for the first time a detailed and comprehensive analysis of the experimental results that set the current world sensitivity limit on the magnitude of the electric dipole moment (EDM) of the neutron. We have extended and enhanced our earlier analysis to include recent developments in the understanding of the effects of gravity in depolarizing ultracold neutrons (UCN); an improved calcula… ▽ More

    Submitted 13 October, 2015; v1 submitted 15 September, 2015; originally announced September 2015.

    Comments: 23 pages, 19 figures. Authorship list changed to put J.M. Pendlebury first. Other very minor edits

    Journal ref: Phys. Rev. D 92, 092003 (2015)

  10. arXiv:1507.08523  [pdf, ps, other

    physics.atom-ph

    A highly stable atomic vector magnetometer based on free spin precession

    Authors: S. Afach, G. Ban, G. Bison, K. Bodek, Z. Chowdhuri, Z. D. Grujic, L. Hayen, V. Helaine, M. Kasprzak, K. Kirch, P. Knowles, H. -C. Koch, S. Komposch, A. Kozela, J. Krempel, B. Lauss, T. Lefort, Y. Lemiere, A. Mtchedlishvili, O. Naviliat-Cuncic, F. M. Piegsa, P. N. Prashanth, G. Quemener, M. Rawlik, D. Ries , et al. (9 additional authors not shown)

    Abstract: We present a magnetometer based on optically pumped Cs atoms that measures the magnitude and direction of a 1 $μ$T magnetic field. Multiple circularly polarized laser beams were used to probe the free spin precession of the Cs atoms. The design was optimized for long-time stability and achieves a scalar resolution better than 300 fT for integration times ranging from 80 ms to 1000 s. The best scal… ▽ More

    Submitted 30 July, 2015; originally announced July 2015.

    Journal ref: Optics Express Vol. 23, Issue 17, pp. 22108-22115 (2015)

  11. arXiv:1506.06563  [pdf, other

    physics.ins-det hep-ex

    Gravitational Depolarization of Ultracold Neutrons: Comparison with Data

    Authors: S. Afach, N. J. Ayres, C. A. Baker, G. Ban, G. Bison, K. Bodek, M. Fertl, B. Franke, P. Geltenbort, K. Green, W. C. Griffith, M. van der Grinten, Z. D. Grujic, P. G. Harris, W. Heil, V. Helaine, P. Iaydjiev, S. N. Ivanov, M. Kasprzak, Y. Kermaidic, K. Kirch, H. -C. Koch, S. Komposch, A. Kozela, J. Krempel , et al. (25 additional authors not shown)

    Abstract: We compare the expected effects of so-called gravitationally enhanced depolarization of ultracold neutrons to measurements carried out in a spin-precession chamber exposed to a variety of vertical magnetic-field gradients. In particular, we have investigated the dependence upon these field gradients of spin depolarization rates and also of shifts in the measured neutron Larmor precession frequency… ▽ More

    Submitted 26 August, 2015; v1 submitted 22 June, 2015; originally announced June 2015.

    Comments: 10 pages, 6 figures. Updated: section added about implications for current nEDM limit

    Journal ref: Phys. Rev. D 92, 052008 (2015)

  12. arXiv:1506.00446  [pdf, other

    physics.ins-det nucl-ex

    Observation of gravitationally induced vertical striation of polarized ultracold neutrons by spin-echo spectroscopy

    Authors: S. Afach, N. J. Ayres, G. Ban, G. Bison, K. Bodek, Z. Chowdhuri, M. Daum, M. Fertl, B. Franke, W. C. Griffith, Z. D. Grujić, P. G. Harris, W. Heil, V. Hélaine, M. Kasprzak, Y. Kermaidic, K. Kirch, P. Knowles, H. -C. Koch, S. Komposch, A. Kozela, J. Krempel, B. Lauss, T. Lefort, Y. Lemière , et al. (23 additional authors not shown)

    Abstract: We describe a spin-echo method for ultracold neutrons (UCNs) confined in a precession chamber and exposed to a $|B_0|=1~\text{μT}$ magnetic field. We have demonstrated that the analysis of UCN spin-echo resonance signals in combination with knowledge of the ambient magnetic field provides an excellent method by which to reconstruct the energy spectrum of a confined ensemble of neutrons. The method… ▽ More

    Submitted 8 September, 2015; v1 submitted 1 June, 2015; originally announced June 2015.

    Comments: 7 pages 5 figures, accepted by PRL, September, 08 2015

    Journal ref: Phys. Rev. Lett. 115, 162502 (2015)

  13. arXiv:1503.08651  [pdf, other

    physics.atom-ph nucl-ex

    Measurement of a false electric dipole moment signal from $^{199}$Hg atoms exposed to an inhomogeneous magnetic field

    Authors: S. Afach, C. A. Baker, G. Ban, G. Bison, K. Bodek, Z. Chowdhuri, M. Daum, M. Fertl, B. Franke, P. Geltenbort, K. Green, M. G. D. van der Grinten, Z. Grujic, P. G. Harris, W. Heil, V. Hélaine, R. Henneck, M. Horras, P. Iaydjiev, S. N. Ivanov, M. Kasprzak, Y. Kermaïdic, K. Kirch, P. Knowles, H. -C. Koch , et al. (24 additional authors not shown)

    Abstract: We report on the measurement of a Larmor frequency shift proportional to the electric-field strength for $^{199}{\rm Hg}$ atoms contained in a volume permeated with aligned magnetic and electric fields. This shift arises from the interplay between the inevitable magnetic field gradients and the motional magnetic field. The proportionality to electric-field strength makes it apparently similar to a… ▽ More

    Submitted 3 August, 2015; v1 submitted 30 March, 2015; originally announced March 2015.

    Journal ref: Eur. Phys. J. D (2015) 69:225

  14. arXiv:1502.06876  [pdf, other

    physics.ins-det nucl-ex

    A device for simultaneous spin analysis of ultracold neutrons

    Authors: S. Afach, G. Ban, G. Bison, K. Bodek, Z. Chowdhuri, M. Daum, M. Fertl, B. Franke, P. Geltenbort, Z. D. Grujić, L. Hayen, V. Hélaine, R. Henneck, M. Kasprzak, Y. Kermaidic, K. Kirch, S. Komposch, A. Kozela, J. Krempel, B. Lauss, T. Lefort, Y. Lemière, A. Mtchedlishvili, O. Naviliat-Cuncic, F. M. Piegsa , et al. (15 additional authors not shown)

    Abstract: We report on the design and first tests of a device allowing for measurement of ultracold neutrons polarisation by means of the simultaneous analysis of the two spin components. The device was developed in the framework of the neutron electric dipole moment experiment at the Paul Scherrer Institute. Individual parts and the entire newly built system have been characterised with ultracold neutrons.… ▽ More

    Submitted 12 October, 2015; v1 submitted 24 February, 2015; originally announced February 2015.

  15. Constraining interactions mediated by axion-like particles with ultracold neutrons

    Authors: S. Afach, G. Ban, G. Bison, K. Bodek, M. Burghoff, M. Daum, M. Fertl, B. Franke, Z. D. Grujić, V. Hélaine, M. Kasprzak, Y. Kermaïdic, K. Kirch, P. Knowles, H. -C. Koch, S. Komposch, A. Kozela, J. Krempel, B. Lauss, T. Lefort, Y. Lemière, A. Mtchedlishvili, O. Naviliat-Cuncic, F. M. Piegsa, G. Pignol , et al. (13 additional authors not shown)

    Abstract: We report a new limit on a possible short range spin-dependent interaction from the precise measurement of the ratio of Larmor precession frequencies of stored ultracold neutrons and $^{199}$Hg atoms confined in the same volume. The measurement was performed in a $\sim$1$μ$ T vertical magnetic holding field with the apparatus searching for a permanent electric dipole moment of the neutron at the P… ▽ More

    Submitted 11 December, 2014; originally announced December 2014.

  16. arXiv:1410.8259  [pdf, other

    nucl-ex physics.atom-ph physics.ins-det

    A measurement of the neutron to 199Hg magnetic moment ratio

    Authors: S. Afach, C. A. Baker, G. Ban, G. Bison, K. Bodek, M. Burghoff, Z. Chowdhuri, M. Daum, M. Fertl, B. Franke, P. Geltenbort, K. Green, M. G. D. van der Grinten, Z. Grujic, P. G. Harris, W. Heil, V. Hélaine, R. Henneck, M. Horras, P. Iaydjiev, S. N. Ivanov, M. Kasprzak, Y. Kermaïdic, K. Kirch, A. Knecht , et al. (29 additional authors not shown)

    Abstract: The neutron gyromagnetic ratio has been measured relative to that of the 199Hg atom with an uncertainty of 0.8 ppm. We employed an apparatus where ultracold neutrons and mercury atoms are stored in the same volume and report the result $γ_{\rm n}/γ_{\rm Hg} = 3.8424574(30)$.

    Submitted 31 October, 2014; v1 submitted 30 October, 2014; originally announced October 2014.

    Journal ref: Physics Letters B 739, 128-132 (2014)

  17. arXiv:1408.6752  [pdf, other

    physics.ins-det nucl-ex physics.atom-ph

    Dynamic stabilization of the magnetic field surrounding the neutron electric dipole moment spectrometer at the Paul Scherrer Institute

    Authors: S. Afach, G. Bison, K. Bodek, F. Burri, Z. Chowdhuri, M. Daum, M. Fertl, B. Franke, Z. Grujic, V. Helaine, R. Henneck, M. Kasprzak, K. Kirch, H. -C. Koch, A. Kozela, J. Krempel, B. Lauss, T. Lefort, Y. Lemiere, M. Meier, O. Naviliat-Cuncic, F. M. Piegsa, G. Pignol, C. Plonka-Spehr, P. N. Prashanth , et al. (12 additional authors not shown)

    Abstract: The Surrounding Field Compensation (SFC) system described in this work is installed around the four-layer Mu-metal magnetic shield of the neutron electric dipole moment spectrometer located at the Paul Scherrer Institute. The SFC system reduces the DC component of the external magnetic field by a factor of about 20. Within a control volume of approximately 2.5m x 2.5m x 3m disturbances of the magn… ▽ More

    Submitted 28 August, 2014; originally announced August 2014.

    Comments: 33 pages, 18 figures

    Journal ref: J. Appl. Phys. 116, 084510 (2014)