-
Modeling temperature-dependent population dynamics in the excited state of the nitrogen-vacancy center in diamond
Authors:
Stefan Ernst,
Patrick J. Scheidegger,
Simon Diesch,
Christian L. Degen
Abstract:
The nitrogen-vacancy (NV) center in diamond is well known in quantum metrology and quantum information for its favorable spin and optical properties, which span a wide temperature range from near zero to over 600 K. Despite its prominence, the NV center's photo-physics is incompletely understood, especially at intermediate temperatures between 10-100 K where phonons become activated. In this work,…
▽ More
The nitrogen-vacancy (NV) center in diamond is well known in quantum metrology and quantum information for its favorable spin and optical properties, which span a wide temperature range from near zero to over 600 K. Despite its prominence, the NV center's photo-physics is incompletely understood, especially at intermediate temperatures between 10-100 K where phonons become activated. In this work, we present a rate model able to describe the cross-over from the low-temperature to the high-temperature regime. Key to the model is a phonon-driven hopping between the two orbital branches in the excited state (ES), which accelerates spin relaxation via an interplay with the ES spin precession. We extend our model to include magnetic and electric fields as well as crystal strain, allowing us to simulate the population dynamics over a wide range of experimental conditions. Our model recovers existing descriptions for the low- and high-temperature limits, and successfully explains various sets of literature data. Further, the model allows us to predict experimental observables, in particular the photoluminescence (PL) emission rate, spin contrast, and spin initialization fidelity relevant for quantum applications. Lastly, our model allows probing the electron-phonon interaction of the NV center and reveals a gap between the current understanding and recent experimental findings.
△ Less
Submitted 31 August, 2023; v1 submitted 5 April, 2023;
originally announced April 2023.
-
Temperature dependence of photoluminescence intensity and spin contrast in nitrogen-vacancy centers
Authors:
Stefan Ernst,
Patrick J. Scheidegger,
Simon Diesch,
Luca Lorenzelli,
Christian L. Degen
Abstract:
We report on measurements of the photoluminescence (PL) properties of single nitrogen-vacancy (NV) centers in diamond at temperatures between 4-300 K. We observe a strong reduction of the PL intensity and spin contrast between ca. 10-100 K that recovers to high levels below and above. Further, we find a rich dependence on magnetic bias field and crystal strain. We develop a comprehensive model bas…
▽ More
We report on measurements of the photoluminescence (PL) properties of single nitrogen-vacancy (NV) centers in diamond at temperatures between 4-300 K. We observe a strong reduction of the PL intensity and spin contrast between ca. 10-100 K that recovers to high levels below and above. Further, we find a rich dependence on magnetic bias field and crystal strain. We develop a comprehensive model based on spin mixing and orbital hopping in the electronic excited state that quantitatively explains the observations. Beyond a more complete understanding of the excited-state dynamics, our work provides a novel approach for probing electron-phonon interactions and a predictive tool for optimizing experimental conditions for quantum applications.
△ Less
Submitted 31 August, 2023; v1 submitted 12 January, 2023;
originally announced January 2023.
-
Scanning nitrogen-vacancy magnetometry down to 350mK
Authors:
Patrick J. Scheidegger,
Simon Diesch,
Marius L. Palm,
Christian L. Degen
Abstract:
We report on the implementation of a scanning nitrogen-vacancy (NV) magnetometer in a dry dilution refrigerator. Using pulsed optically detected magnetic resonance combined with efficient microwave delivery through a co-planar waveguide, we reach a base temperature of 350 mK, limited by experimental heat load and thermalization of the probe. We demonstrate scanning NV magnetometry by imaging super…
▽ More
We report on the implementation of a scanning nitrogen-vacancy (NV) magnetometer in a dry dilution refrigerator. Using pulsed optically detected magnetic resonance combined with efficient microwave delivery through a co-planar waveguide, we reach a base temperature of 350 mK, limited by experimental heat load and thermalization of the probe. We demonstrate scanning NV magnetometry by imaging superconducting vortices in a 50-nm-thin aluminum microstructure. The sensitivity of our measurements is approximately 3 μT per square root Hz. Our work demonstrates the feasibility for performing non-invasive magnetic field imaging with scanning NV centers at sub-Kelvin temperatures.
△ Less
Submitted 31 May, 2022; v1 submitted 29 March, 2022;
originally announced March 2022.
-
Imaging of sub-$μ$A currents in bilayer graphene using a scanning diamond magnetometer
Authors:
M. L. Palm,
W. S. Huxter,
P. Welter,
S. Ernst,
P. J. Scheidegger,
S. Diesch,
K. Chang,
P. Rickhaus,
T. Taniguchi,
K. Wantanabe,
K. Ensslin,
C. L. Degen
Abstract:
Nanoscale electronic transport gives rise to a number of intriguing physical phenomena that are accompanied by distinct spatial patterns of current flow. Here, we report on sensitive magnetic imaging of two-dimensional current distributions in bilayer graphene at room temperature. By combining dynamical modulation of the source-drain current with ac quantum sensing of a nitrogen-vacancy center in…
▽ More
Nanoscale electronic transport gives rise to a number of intriguing physical phenomena that are accompanied by distinct spatial patterns of current flow. Here, we report on sensitive magnetic imaging of two-dimensional current distributions in bilayer graphene at room temperature. By combining dynamical modulation of the source-drain current with ac quantum sensing of a nitrogen-vacancy center in a diamond probe, we acquire magnetic field and current density maps with excellent sensitivities of 4.6 nT and 20 nA/$μ$m, respectively. The spatial resolution is 50-100 nm. We further introduce a set of methods for increasing the technique's dynamic range and for mitigating undesired back-action of magnetometry operation on the electronic transport. Current density maps reveal local variations in the flow pattern and global tuning of current flow via the back-gate potential. No signatures of hydrodynamic transport are observed. Our experiments demonstrate the feasibility for imaging subtle features of nanoscale transport in two-dimensional materials and conductors.
△ Less
Submitted 18 January, 2022;
originally announced January 2022.
-
NV-Diamond Magnetic Microscopy using a Double Quantum 4-Ramsey Protocol
Authors:
Connor A. Hart,
Jennifer M. Schloss,
Matthew J. Turner,
Patrick J. Scheidegger,
Erik Bauch,
Ronald L. Walsworth
Abstract:
We introduce a double quantum (DQ) 4-Ramsey measurement protocol that enables wide-field magnetic imaging using nitrogen vacancy (NV) centers in diamond, with enhanced homogeneity of the magnetic sensitivity relative to conventional single quantum (SQ) techniques. The DQ 4-Ramsey protocol employs microwave-phase alternation across four consecutive Ramsey (4-Ramsey) measurements to isolate the desi…
▽ More
We introduce a double quantum (DQ) 4-Ramsey measurement protocol that enables wide-field magnetic imaging using nitrogen vacancy (NV) centers in diamond, with enhanced homogeneity of the magnetic sensitivity relative to conventional single quantum (SQ) techniques. The DQ 4-Ramsey protocol employs microwave-phase alternation across four consecutive Ramsey (4-Ramsey) measurements to isolate the desired DQ magnetic signal from any residual SQ signal induced by microwave pulse errors. In a demonstration experiment employing a 1-$μ$m-thick NV layer in a macroscopic diamond chip, the DQ 4-Ramsey protocol provides volume-normalized DC magnetic sensitivity of $η^\text{V}=34\,$nTHz$^{-1/2} μ$m$^{3/2}$ across a $125\,μ$m$ \,\times\,125\,μ$m field of view, with about 5$\times$ less spatial variation in sensitivity across the field of view compared to a SQ measurement. The improved robustness and magnetic sensitivity homogeneity of the DQ 4-Ramsey protocol enable imaging of dynamic, broadband magnetic sources such as integrated circuits and electrically-active cells.
△ Less
Submitted 21 April, 2021; v1 submitted 4 September, 2020;
originally announced September 2020.