-
Experimental advances with the QICK (Quantum Instrumentation Control Kit) for superconducting quantum hardware
Authors:
Chunyang Ding,
Martin Di Federico,
Michael Hatridge,
Andrew Houck,
Sebastien Leger,
Jeronimo Martinez,
Connie Miao,
David I. Schuster,
Leandro Stefanazzi,
Chris Stoughton,
Sara Sussman,
Ken Treptow,
Sho Uemura,
Neal Wilcer,
Helin Zhang,
Chao Zhou,
Gustavo Cancelo
Abstract:
The QICK is a standalone open source qubit controller that was first introduced in 2022. In this follow-up work, we present recent experimental use cases that the QICK uniquely enabled for superconducting qubit systems. These include multiplexed signal generation and readout, mixer-free readout, pre-distorted fast flux pulses, and phase-coherent pulses for parametric operations, including high-fid…
▽ More
The QICK is a standalone open source qubit controller that was first introduced in 2022. In this follow-up work, we present recent experimental use cases that the QICK uniquely enabled for superconducting qubit systems. These include multiplexed signal generation and readout, mixer-free readout, pre-distorted fast flux pulses, and phase-coherent pulses for parametric operations, including high-fidelity parametric entangling gates. We explain in detail how the QICK was used to enable these experiments.
△ Less
Submitted 28 November, 2023;
originally announced November 2023.
-
The QICK (Quantum Instrumentation Control Kit): Readout and control for qubits and detectors
Authors:
Leandro Stefanazzi,
Ken Treptow,
Neal Wilcer,
Chris Stoughton,
Salvatore Montella,
Collin Bradford,
Gustavo Cancelo,
Shefali Saxena,
Horacio Arnaldi,
Sara Sussman,
Andrew Houck,
Ankur Agrawal,
Helin Zhang,
Chunyang Ding,
David I Schuster
Abstract:
We introduce a Xilinx RFSoC-based qubit controller (called the Quantum Instrumentation Control Kit, or QICK for short) which supports the direct synthesis of control pulses with carrier frequencies of up to 6 GHz. The QICK can control multiple qubits or other quantum devices. The QICK consists of a digital board hosting an RFSoC (RF System-on-Chip) FPGA \cite{zcu111}, custom firmware and software…
▽ More
We introduce a Xilinx RFSoC-based qubit controller (called the Quantum Instrumentation Control Kit, or QICK for short) which supports the direct synthesis of control pulses with carrier frequencies of up to 6 GHz. The QICK can control multiple qubits or other quantum devices. The QICK consists of a digital board hosting an RFSoC (RF System-on-Chip) FPGA \cite{zcu111}, custom firmware and software and an optional companion custom-designed analog front-end board. We characterize the analog performance of the system, as well as its digital latency, important for quantum error correction and feedback protocols. We benchmark the controller by performing standard characterizations of a transmon qubit. We achieve an average Clifford gate fidelity of $\mathcal{F}_{avg}=99.93\%$. All of the schematics, firmware, and software are open-source \cite{QICKrepo}.
△ Less
Submitted 10 March, 2022; v1 submitted 1 October, 2021;
originally announced October 2021.
-
Second Generation Readout For Large Format Photon Counting Microwave Kinetic Inductance Detectors
Authors:
Neelay Fruitwala,
Paschal Strader,
Gustavo Cancelo,
Ted Zmuda,
Ken Treptow,
Neal Wilcer,
Chris Stoughton,
Alex B. Walter,
Nicholas Zobrist,
Giulia Collura,
Isabel Lipartito,
John I. Bailey III,
Benjamin A. Mazin
Abstract:
We present the development of a second generation digital readout system for photon counting microwave kinetic inductance detector (MKID) arrays operating in the optical and near-IR wavelength bands. Our system retains much of the core signal processing architecture from the first generation system, but with a significantly higher bandwidth, enabling readout of kilopixel MKID arrays. Each set of r…
▽ More
We present the development of a second generation digital readout system for photon counting microwave kinetic inductance detector (MKID) arrays operating in the optical and near-IR wavelength bands. Our system retains much of the core signal processing architecture from the first generation system, but with a significantly higher bandwidth, enabling readout of kilopixel MKID arrays. Each set of readout boards is capable of reading out 1024 MKID pixels multiplexed over 2 GHz of bandwidth; two such units can be placed in parallel to read out a full 2048 pixel microwave feedline over a 4 -- 8 GHz band. As in the first generation readout, our system is capable of identifying, analyzing, and recording photon detection events in real time with a time resolution of order a few microseconds. Here, we describe the hardware and firmware, and present an analysis of the noise properties of the system. We also present a novel algorithm for efficiently suppressing IQ mixer sidebands to below -30 dBc.
△ Less
Submitted 12 November, 2020;
originally announced November 2020.
-
Low Threshold Acquisition controller for Skipper CCDs
Authors:
Gustavo Cancelo,
Claudio Chavez,
Fernando Chierchie,
Juan Estrada,
Guillermo Fernandez Moroni,
Eduardo Emilio Paolini,
Miguel Sofo Haro,
Angel Soto,
Leandro Stefanazzi,
Javier Tiffenberg,
Ken Treptow,
Neal Wilcer,
Ted Zmuda
Abstract:
The development of the Skipper Charge Coupled Devices (Skipper-CCDs) has been a major technological breakthrough for sensing very weak ionizing particles. The sensor allows to reach the ultimate sensitivity of silicon material as a charge signal sensor by unambiguous determination of the charge signal collected by each cell or pixel, even for single electron-hole pair ionization. Extensive use of…
▽ More
The development of the Skipper Charge Coupled Devices (Skipper-CCDs) has been a major technological breakthrough for sensing very weak ionizing particles. The sensor allows to reach the ultimate sensitivity of silicon material as a charge signal sensor by unambiguous determination of the charge signal collected by each cell or pixel, even for single electron-hole pair ionization. Extensive use of the technology was limited by the lack of specific equipment to operate the sensor at the ultimate performance. In this work a simple, single-board Skipper-CCD controller is presented, aimed for the operation of the detector in high sensitivity scientific applications. The article describes the main components and functionality of the Low Threshold Acquisition (LTA) together with experimental results when connected to a Skipper-CCD sensor. Measurements show unprecedented deep sub-electron noise of 0.039 e$^-_{rms}$/pix for 5000 pixel measurements.
△ Less
Submitted 16 April, 2020;
originally announced April 2020.
-
DARKNESS: A Microwave Kinetic Inductance Detector Integral Field Spectrograph for High-Contrast Astronomy
Authors:
Seth R. Meeker,
Benjamin A. Mazin,
Alex B. Walter,
Paschal Strader,
Neelay Fruitwala,
Clint Bockstiegel,
Paul Szypryt,
Gerhard Ulbricht,
Gregoire Coiffard,
Bruce Bumble,
Gustavo Cancelo,
Ted Zmuda,
Ken Treptow,
Neal Wilcer,
Giulia Collura,
Rupert Dodkins,
Isabel Lipartito,
Nicholas Zobrist,
Michael Bottom,
J. Chris Shelton,
Dimitri Mawet,
Julian C. van Eyken,
Gautam Vasisht,
Eugene Serabyn
Abstract:
We present DARKNESS (the DARK-speckle Near-infrared Energy-resolving Superconducting Spectrophotometer), the first of several planned integral field spectrographs to use optical/near-infrared Microwave Kinetic Inductance Detectors (MKIDs) for high-contrast imaging. The photon counting and simultaneous low-resolution spectroscopy provided by MKIDs will enable real-time speckle control techniques an…
▽ More
We present DARKNESS (the DARK-speckle Near-infrared Energy-resolving Superconducting Spectrophotometer), the first of several planned integral field spectrographs to use optical/near-infrared Microwave Kinetic Inductance Detectors (MKIDs) for high-contrast imaging. The photon counting and simultaneous low-resolution spectroscopy provided by MKIDs will enable real-time speckle control techniques and post-processing speckle suppression at framerates capable of resolving the atmospheric speckles that currently limit high-contrast imaging from the ground. DARKNESS is now operational behind the PALM-3000 extreme adaptive optics system and the Stellar Double Coronagraph at Palomar Observatory. Here we describe the motivation, design, and characterization of the instrument, early on-sky results, and future prospects.
△ Less
Submitted 16 April, 2018; v1 submitted 28 March, 2018;
originally announced March 2018.
-
Importance of van der Waals interactions and cation-anion coupling in an organic quantum spin liquid
Authors:
P. Lazić,
M. Pinterić,
D. Rivas Góngora,
A. Pustogow,
K. Treptow,
T. Ivek,
O. Milat,
B. Gumhalter,
N. Došlić,
M. Dressel,
S. Tomić
Abstract:
The Mott insulator $β'$-EtMe$_3$Sb[Pd(dmit)$_2$]$_2$ belongs to a class of charge transfer solids with highly-frustrated triangular lattice of $S=1/2$ molecular dimers and a quantum-spin-liquid ground state. Our experimental and ab initio theoretical studies show the fingerprints of strong correlations and disorder, important role of cation-dimer bonding in charge redistribution, no sign of intra-…
▽ More
The Mott insulator $β'$-EtMe$_3$Sb[Pd(dmit)$_2$]$_2$ belongs to a class of charge transfer solids with highly-frustrated triangular lattice of $S=1/2$ molecular dimers and a quantum-spin-liquid ground state. Our experimental and ab initio theoretical studies show the fingerprints of strong correlations and disorder, important role of cation-dimer bonding in charge redistribution, no sign of intra- and inter-dimer dipoles, and the decisive van der Waals contribution to inter-dimer interactions and the ground state structure. The latter consists of quasi-degenerate electronic states related to the different configurations of cation moieties which permit two different equally probable orientations. Upon reducing the temperature, the low-energy excitations slow down, indicating glassy signatures as the cation motion freezes out.
△ Less
Submitted 27 December, 2017; v1 submitted 5 October, 2017;
originally announced October 2017.
-
Operational experience, improvements, and performance of the CDF Run II silicon vertex detector
Authors:
T. Aaltonen,
S. Behari,
A. Boveia,
B. Brau,
G. Bolla,
D. Bortoletto,
C. Calancha,
S. Carron,
S. Cihangir,
M. Corbo,
D. Clark,
B. Di Ruzza,
R. Eusebi,
J. P. Fernandez,
J. C. Freeman,
J. E. Garcia,
M. Garcia-Sciveres,
D. Glenzinski,
O. Gonzalez,
S. Grinstein,
M. Hartz,
M. Herndon,
C. Hill,
A. Hocker,
U. Husemann
, et al. (35 additional authors not shown)
Abstract:
The Collider Detector at Fermilab (CDF) pursues a broad physics program at Fermilab's Tevatron collider. Between Run II commissioning in early 2001 and the end of operations in September 2011, the Tevatron delivered 12 fb-1 of integrated luminosity of p-pbar collisions at sqrt(s)=1.96 TeV. Many physics analyses undertaken by CDF require heavy flavor tagging with large charged particle tracking acc…
▽ More
The Collider Detector at Fermilab (CDF) pursues a broad physics program at Fermilab's Tevatron collider. Between Run II commissioning in early 2001 and the end of operations in September 2011, the Tevatron delivered 12 fb-1 of integrated luminosity of p-pbar collisions at sqrt(s)=1.96 TeV. Many physics analyses undertaken by CDF require heavy flavor tagging with large charged particle tracking acceptance. To realize these goals, in 2001 CDF installed eight layers of silicon microstrip detectors around its interaction region. These detectors were designed for 2--5 years of operation, radiation doses up to 2 Mrad (0.02 Gy), and were expected to be replaced in 2004. The sensors were not replaced, and the Tevatron run was extended for several years beyond its design, exposing the sensors and electronics to much higher radiation doses than anticipated. In this paper we describe the operational challenges encountered over the past 10 years of running the CDF silicon detectors, the preventive measures undertaken, and the improvements made along the way to ensure their optimal performance for collecting high quality physics data. In addition, we describe the quantities and methods used to monitor radiation damage in the sensors for optimal performance and summarize the detector performance quantities important to CDF's physics program, including vertex resolution, heavy flavor tagging, and silicon vertex trigger performance.
△ Less
Submitted 3 October, 2013; v1 submitted 14 January, 2013;
originally announced January 2013.
-
Tevatron Beam Position Monitor Upgrade
Authors:
G. Annala,
B. Banerjee,
B. Barker,
T. Boes,
M. Bowden,
C. Briegel,
G. Cancelo,
G. Duerling,
B. Forster,
S. Foulkes,
B. Haynes,
B. Hendricks,
T. Kasza,
R. Kutschke,
R. Mahlum,
M. Martens,
M. Olson,
V. Pavlicek,
L. Piccoli,
P. Prieto,
J. Steimel,
K. Treptow,
M. Votava,
D. Voy,
M. Wendt
, et al. (2 additional authors not shown)
Abstract:
This paper describes the development of a digital-based Beam Position System which was designed, developed, and adapted for the Tevatron during Collider Run II.
This paper describes the development of a digital-based Beam Position System which was designed, developed, and adapted for the Tevatron during Collider Run II.
△ Less
Submitted 26 September, 2012;
originally announced September 2012.
-
Deep sub electron noise readout in CCD systems using digital filtering techniques
Authors:
Gustavo Cancelo,
Juan Estrada,
Guillermo Fernandez Moroni,
Ken Treptow,
Ted Zmuda,
Tom Diehl
Abstract:
Scientific CCDs designed in thick high resistivity silicon (Si) are excellent detectors for astronomy, high energy and nuclear physics, and instrumentation. Many applications can benefit from CCDs ultra low noise readout systems. The present work shows how sub electron noise CCD images can be achieved using digital signal processing techniques. These techniques allow readout bandwidths of up to 10…
▽ More
Scientific CCDs designed in thick high resistivity silicon (Si) are excellent detectors for astronomy, high energy and nuclear physics, and instrumentation. Many applications can benefit from CCDs ultra low noise readout systems. The present work shows how sub electron noise CCD images can be achieved using digital signal processing techniques. These techniques allow readout bandwidths of up to 10 K pixels per second and keep the full CCD spatial resolution and signal dynamic range.
△ Less
Submitted 5 July, 2011;
originally announced July 2011.