-
A blind detection of a large, complex, Sunyaev--Zel'dovich structure
Authors:
AMI Consortium,
:,
T. W. Shimwell,
R. W. Barker,
P. Biddulph,
D. Bly,
R. C. Boysen,
A. R. Brown,
M. L. Brown,
C. Clementson,
M. Crofts,
T. L. Culverhouse,
J. Czeres,
R. J. Dace,
M. L. Davies,
R. D'Alessandro,
P. Doherty,
K. Duggan,
J. A. Ely,
M. Felvus,
F. Feroz,
W. Flynn,
T. M. O. Franzen,
J. Geisbusch,
R. Genova-Santos
, et al. (36 additional authors not shown)
Abstract:
We present an interesting Sunyaev-Zel'dovich (SZ) detection in the first of the Arcminute Microkelvin Imager (AMI) 'blind', degree-square fields to have been observed down to our target sensitivity of 100μJy/beam. In follow-up deep pointed observations the SZ effect is detected with a maximum peak decrement greater than 8 \times the thermal noise. No corresponding emission is visible in the ROSAT…
▽ More
We present an interesting Sunyaev-Zel'dovich (SZ) detection in the first of the Arcminute Microkelvin Imager (AMI) 'blind', degree-square fields to have been observed down to our target sensitivity of 100μJy/beam. In follow-up deep pointed observations the SZ effect is detected with a maximum peak decrement greater than 8 \times the thermal noise. No corresponding emission is visible in the ROSAT all-sky X-ray survey and no cluster is evident in the Palomar all-sky optical survey. Compared with existing SZ images of distant clusters, the extent is large (\approx 10') and complex; our analysis favours a model containing two clusters rather than a single cluster. Our Bayesian analysis is currently limited to modelling each cluster with an ellipsoidal or spherical beta-model, which do not do justice to this decrement. Fitting an ellipsoid to the deeper candidate we find the following. (a) Assuming that the Evrard et al. (2002) approximation to Press & Schechter (1974) correctly gives the number density of clusters as a function of mass and redshift, then, in the search area, the formal Bayesian probability ratio of the AMI detection of this cluster is 7.9 \times 10^4:1; alternatively assuming Jenkins et al. (2001) as the true prior, the formal Bayesian probability ratio of detection is 2.1 \times 10^5:1. (b) The cluster mass is MT,200 = 5.5+1.2\times 10^14h-1M\odot. (c) Abandoning a physical model with num- -1.3 70 ber density prior and instead simply modelling the SZ decrement using a phenomenological β-model of temperature decrement as a function of angular distance, we find a central SZ temperature decrement of -295+36 μK - this allows for CMB primary anisotropies, receiver -15 noise and radio sources. We are unsure if the cluster system we observe is a merging system or two separate clusters.
△ Less
Submitted 22 March, 2012; v1 submitted 20 December, 2010;
originally announced December 2010.
-
HARP/ACSIS: A submillimetre spectral imaging system on the James Clerk Maxwell Telescope
Authors:
J. V. Buckle,
R. E. Hills,
H. Smith,
W. R. F. Dent,
G. Bell,
E. I. Curtis,
R. Dace,
H. Gibson,
S. F. Graves,
J. Leech,
J. S. Richer,
R. Williamson,
S. Withington,
G. Yassin,
R. Bennett,
P. Hastings,
I. Laidlaw,
J. F. Lightfoot,
T. Burgess,
P. E. Dewdney,
G. Hovey,
A. G. Willis,
R. Redman,
B. Wooff,
D. S. Berry
, et al. (13 additional authors not shown)
Abstract:
This paper describes a new Heterodyne Array Receiver Programme (HARP) and Auto-Correlation Spectral Imaging System (ACSIS) that have recently been installed and commissioned on the James Clerk Maxwell Telescope (JCMT). The 16-element focal-plane array receiver, operating in the submillimetre from 325 to 375 GHz, offers high (three-dimensional) mapping speeds, along with significant improvements…
▽ More
This paper describes a new Heterodyne Array Receiver Programme (HARP) and Auto-Correlation Spectral Imaging System (ACSIS) that have recently been installed and commissioned on the James Clerk Maxwell Telescope (JCMT). The 16-element focal-plane array receiver, operating in the submillimetre from 325 to 375 GHz, offers high (three-dimensional) mapping speeds, along with significant improvements over single-detector counterparts in calibration and image quality. Receiver temperatures are $\sim$120 K across the whole band and system temperatures of $\sim$300K are reached routinely under good weather conditions. The system includes a single-sideband filter so these are SSB figures. Used in conjunction with ACSIS, the system can produce large-scale maps rapidly, in one or more frequency settings, at high spatial and spectral resolution. Fully-sampled maps of size 1 square degree can be observed in under 1 hour.
The scientific need for array receivers arises from the requirement for programmes to study samples of objects of statistically significant size, in large-scale unbiased surveys of galactic and extra-galactic regions. Along with morphological information, the new spectral imaging system can be used to study the physical and chemical properties of regions of interest. Its three-dimensional imaging capabilities are critical for research into turbulence and dynamics. In addition, HARP/ACSIS will provide highly complementary science programmes to wide-field continuum studies, and produce the essential preparatory work for submillimetre interferometers such as the SMA and ALMA.
△ Less
Submitted 21 July, 2009;
originally announced July 2009.
-
The Arcminute Microkelvin Imager
Authors:
AMI Consortium,
:,
J. T. L. Zwart,
R. W. Barker,
P. Biddulph,
D. Bly,
R. C. Boysen,
A. R. Brown,
C. Clementson,
M. Crofts,
T. L. Culverhouse,
J. Czeres,
R. J. Dace,
M. L. Davies,
R. D'Alessandro,
P. Doherty,
K. Duggan,
J. A. Ely,
M. Felvus,
F. Feroz,
W. Flynn,
T. M. O. Franzen,
J. Geisbüsch,
R. Génova-Santos,
K. J. B. Grainge
, et al. (35 additional authors not shown)
Abstract:
The Arcminute Microkelvin Imager is a pair of interferometer arrays operating with six frequency channels spanning 13.9-18.2 GHz, with very high sensitivity to angular scales 30''-10'. The telescope is aimed principally at Sunyaev-Zel'dovich imaging of clusters of galaxies. We discuss the design of the telescope and describe and explain its electronic and mechanical systems.
The Arcminute Microkelvin Imager is a pair of interferometer arrays operating with six frequency channels spanning 13.9-18.2 GHz, with very high sensitivity to angular scales 30''-10'. The telescope is aimed principally at Sunyaev-Zel'dovich imaging of clusters of galaxies. We discuss the design of the telescope and describe and explain its electronic and mechanical systems.
△ Less
Submitted 15 July, 2008;
originally announced July 2008.
-
Prototype finline-coupled TES bolometers for CLOVER
Authors:
Michael D. Audley,
Robert W. Barker,
Michael Crane,
Roger Dace,
Dorota Glowacka,
David J. Goldie,
Anthony N. Lasenby,
Howard M. Stevenson,
Vassilka Tsaneva,
Stafford Withington,
Paul Grimes,
Bradley Johnson,
Ghassan Yassin,
Lucio Piccirillo,
Giampaolo Pisano,
William D. Duncan,
Gene C. Hilton,
Kent D. Irwin,
Carl D. Reintsema,
Mark Halpern
Abstract:
CLOVER is an experiment which aims to detect the signature of gravitational waves from inflation by measuring the B-mode polarization of the cosmic microwave background. CLOVER consists of three telescopes operating at 97, 150, and 220 GHz. The 97-GHz telescope has 160 feedhorns in its focal plane while the 150 and 220-GHz telescopes have 256 horns each. The horns are arranged in a hexagonal arr…
▽ More
CLOVER is an experiment which aims to detect the signature of gravitational waves from inflation by measuring the B-mode polarization of the cosmic microwave background. CLOVER consists of three telescopes operating at 97, 150, and 220 GHz. The 97-GHz telescope has 160 feedhorns in its focal plane while the 150 and 220-GHz telescopes have 256 horns each. The horns are arranged in a hexagonal array and feed a polarimeter which uses finline-coupled TES bolometers as detectors. To detect the two polarizations the 97-GHz telescope has 320 detectors while the 150 and 220-GHz telescopes have 512 detectors each. To achieve the target NEPs (1.5, 2.5, and 4.5x10^-17 W/rtHz) the detectors are cooled to 100 mK for the 97 and 150-GHz polarimeters and 230 mK for the 220-GHz polarimeter. Each detector is fabricated as a single chip to ensure a 100% operational focal plane. The detectors are contained in linear modules made of copper which form split-block waveguides. The detector modules contain 16 or 20 detectors each for compatibility with the hexagonal arrays of horns in the telescopes' focal planes. Each detector module contains a time-division SQUID multiplexer to read out the detectors. Further amplification of the multiplexed signals is provided by SQUID series arrays. The first prototype detectors for CLOVER operate with a bath temperature of 230 mK and are used to validate the detector design as well as the polarimeter technology. We describe the design of the CLOVER detectors, detector blocks, and readout, and present preliminary measurements of the prototype detectors performance.
△ Less
Submitted 14 August, 2006;
originally announced August 2006.
-
TES imaging array technology for CLOVER
Authors:
Michael D. Audley,
Robert W. Barker,
Michael Crane,
Roger Dace,
Dorota Glowacka,
David J. Goldie,
Anthony N. Lasenby,
Howard M. Stevenson,
Vassilka Tsaneva,
Stafford Withington,
Paul Grimes,
Bradley Johnson,
Ghassan Yassin,
Lucio Piccirillo,
Giampaolo Pisano,
William D. Duncan,
Gene C. Hilton,
Kent D. Irwin,
Carl D. Reintsema,
Mark Halpern
Abstract:
CLOVER is an experiment which aims to detect the signature of gravitational waves from inflation by measuring the B-mode polarization of the cosmic microwave background. CLOVER consists of three telescopes operating at 97, 150, and 220 GHz. The 97-GHz telescope has 160 horns in its focal plane while the 150 and 220-GHz telescopes have 256 horns each. The horns are arranged in a hexagonal array a…
▽ More
CLOVER is an experiment which aims to detect the signature of gravitational waves from inflation by measuring the B-mode polarization of the cosmic microwave background. CLOVER consists of three telescopes operating at 97, 150, and 220 GHz. The 97-GHz telescope has 160 horns in its focal plane while the 150 and 220-GHz telescopes have 256 horns each. The horns are arranged in a hexagonal array and feed a polarimeter which uses finline-coupled TES bolometers as detectors. To detect the two polarizations the 97-GHz telescope has 320 detectors while the 150 and 220-GHz telescopes have 512 detectors each. To achieve the required NEPs the detectors are cooled to 100 mK for the 97 and 150-GHz polarimeters and 230 mK for the 220-GHz polarimeter. Each detector is fabricated as a single chip to guarantee fully functioning focal planes. The detectors are contained in linear modules made of copper which form split-block waveguides. The detector modules contain 16 or 20 detectors each for compatibility with the hexagonal arrays of horns in the telescopes' focal planes. Each detector module contains a time-division SQUID multiplexer to read out the detectors. Further amplification of the multiplexed signals is provided by SQUID series arrays. The first prototype detectors for CLOVER operate with a bath temperature of 230 mK and are used to validate the detector design as well as the polarimeter technology. We describe the design of the CLOVER detectors, detector blocks, and readout, and give an update on the detector development.
△ Less
Submitted 5 July, 2006;
originally announced July 2006.
-
High-significance Sunyaev-Zel'dovich measurement: Abell 1914 seen with the Arcminute Microkelvin Imager
Authors:
AMI Collaboration,
R. Barker,
P. Biddulph,
D. Bly,
R. Boysen,
A. Brown,
C. Clementson,
M. Crofts,
T. Culverhouse,
J. Czeres,
R. Dace,
R. D'Alessandro,
P. Doherty,
P. Duffett-Smith,
K. Duggan,
J. Ely,
M. Felvus,
W. Flynn,
J. Geisbuesch,
K. Grainge,
W. Grainger,
D. Hammet,
R. Hills,
M. Hobson,
C. Holler
, et al. (25 additional authors not shown)
Abstract:
We report the first detection of a Sunyaev-Zel'dovich (S-Z) decrement with the Arcminute Microkelvin Imager (AMI). We have made commissioning observations towards the cluster A1914 and have measured an integrated flux density of -8.61 mJy in a uv-tapered map with noise level 0.19 mJy/beam. We find that the spectrum of the decrement, measured in the six channels between 13.5-18GHz, is consistent…
▽ More
We report the first detection of a Sunyaev-Zel'dovich (S-Z) decrement with the Arcminute Microkelvin Imager (AMI). We have made commissioning observations towards the cluster A1914 and have measured an integrated flux density of -8.61 mJy in a uv-tapered map with noise level 0.19 mJy/beam. We find that the spectrum of the decrement, measured in the six channels between 13.5-18GHz, is consistent with that expected for a S-Z effect. The sensitivity of the telescope is consistent with the figures used in our simulations of cluster surveys with AMI.
△ Less
Submitted 8 September, 2005;
originally announced September 2005.