-
Status of Xtend telescope onboard X-Ray Imaging and Spectroscopy Mission (XRISM)
Authors:
Koji Mori,
Hiroshi Tomida,
Hiroshi Nakajima,
Takashi Okajima,
Hirofumi Noda,
Hiroyuki Uchida,
Hiromasa Suzuki,
Shogo Benjamin Kobayashi,
Tomokage Yoneyama,
Kouichi Hagino,
Kumiko Nobukawa,
Takaaki Tanaka,
Hiroshi Murakami,
Hideki Uchiyama,
Masayoshi Nobukawa,
Hironori Matsumoto,
Takeshi Tsuru,
Makoto Yamauchi,
Isamu Hatsukade,
Hirokazu Odaka,
Takayoshi Kohmura,
Kazutaka Yamaoka,
Manabu Ishida,
Yoshitomo Maeda,
Takayuki Hayashi
, et al. (38 additional authors not shown)
Abstract:
Xtend is one of the two telescopes onboard the X-ray imaging and spectroscopy mission (XRISM), which was launched on September 7th, 2023. Xtend comprises the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. A large field of view of $38^{\prime}\times38^{\prime}$ over the energy range from 0.4 to 13 keV is…
▽ More
Xtend is one of the two telescopes onboard the X-ray imaging and spectroscopy mission (XRISM), which was launched on September 7th, 2023. Xtend comprises the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. A large field of view of $38^{\prime}\times38^{\prime}$ over the energy range from 0.4 to 13 keV is realized by the combination of the SXI and XMA with a focal length of 5.6 m. The SXI employs four P-channel, back-illuminated type CCDs with a thick depletion layer of 200 $μ$m. The four CCD chips are arranged in a 2$\times$2 grid and cooled down to $-110$ $^{\circ}$C with a single-stage Stirling cooler. Before the launch of XRISM, we conducted a month-long spacecraft thermal vacuum test. The performance verification of the SXI was successfully carried out in a course of multiple thermal cycles of the spacecraft. About a month after the launch of XRISM, the SXI was carefully activated and the soundness of its functionality was checked by a step-by-step process. Commissioning observations followed the initial operation. We here present pre- and post-launch results verifying the Xtend performance. All the in-orbit performances are consistent with those measured on ground and satisfy the mission requirement. Extensive calibration studies are ongoing.
△ Less
Submitted 28 June, 2024;
originally announced June 2024.
-
Initial operations of the Soft X-ray Imager onboard XRISM
Authors:
Hiromasa Suzuki,
Tomokage Yoneyama,
Shogo B. Kobayashi,
Hirofumi Noda,
Hiroyuki Uchida,
Kumiko K. Nobukawa,
Kouichi Hagino,
Koji Mori,
Hiroshi Tomida,
Hiroshi Nakajima,
Takaaki Tanaka,
Hiroshi Murakami,
Hideki Uchiyama,
Masayoshi Nobukawa,
Yoshiaki Kanemaru,
Yoshinori Otsuka,
Haruhiko Yokosu,
Wakana Yonemaru,
Hanako Nakano,
Kazuhiro Ichikawa,
Reo Takemoto,
Tsukasa Matsushima,
Marina Yoshimoto,
Mio Aoyagi,
Kohei Shima
, et al. (30 additional authors not shown)
Abstract:
XRISM (X-Ray Imaging and Spectroscopy Mission) is an astronomical satellite with the capability of high-resolution spectroscopy with the X-ray microcalorimeter, Resolve, and wide field-of-view imaging with the CCD camera, Xtend. The Xtend consists of the mirror assembly (XMA: X-ray Mirror Assembly) and detector (SXI: Soft X-ray Imager). The components of SXI include CCDs, analog and digital electr…
▽ More
XRISM (X-Ray Imaging and Spectroscopy Mission) is an astronomical satellite with the capability of high-resolution spectroscopy with the X-ray microcalorimeter, Resolve, and wide field-of-view imaging with the CCD camera, Xtend. The Xtend consists of the mirror assembly (XMA: X-ray Mirror Assembly) and detector (SXI: Soft X-ray Imager). The components of SXI include CCDs, analog and digital electronics, and a mechanical cooler. After the successful launch on September 6th, 2023 (UT) and subsequent critical operations, the mission instruments were turned on and set up. The CCDs have been kept at the designed operating temperature of $-110^\circ$C ~after the electronics and cooling system were successfully set up. During the initial operation phase, which continued for more than a month after the critical operations, we verified the observation procedure, stability of the cooling system, all the observation options with different imaging areas and/or timing resolutions, and operations for protection against South Atlantic Anomaly. We optimized the operation procedure and observation parameters including the cooler settings, imaging areas for the specific modes with higher timing resolutions, and event selection algorithm. We summarize our policy and procedure of the initial operations for SXI. We also report on a couple of issues we faced during the initial operations and lessons learned from them.
△ Less
Submitted 28 June, 2024;
originally announced June 2024.
-
Xtend, the Soft X-ray Imaging Telescope for the X-ray Imaging and Spectroscopy Mission (XRISM)
Authors:
Koji Mori,
Hiroshi Tomida,
Hiroshi Nakajima,
Takashi Okajima,
Hirofumi Noda,
Takaaki Tanaka,
Hiroyuki Uchida,
Kouichi Hagino,
Shogo Benjamin Kobayashi,
Hiromasa Suzuki,
Tessei Yoshida,
Hiroshi Murakami,
Hideki Uchiyama,
Masayoshi Nobukawa,
Kumiko Nobukawa,
Tomokage Yoneyama,
Hironori Matsumoto,
Takeshi Tsuru,
Makoto Yamauchi,
Isamu Hatsukade,
Manabu Ishida,
Yoshitomo Maeda,
Takayuki Hayashi,
Keisuke Tamura,
Rozenn Boissay-Malaquin
, et al. (30 additional authors not shown)
Abstract:
Xtend is a soft X-ray imaging telescope developed for the X-Ray Imaging and Spectroscopy Mission (XRISM). XRISM is scheduled to be launched in the Japanese fiscal year 2022. Xtend consists of the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. The SXI uses the P-channel, back-illuminated type CCD with an…
▽ More
Xtend is a soft X-ray imaging telescope developed for the X-Ray Imaging and Spectroscopy Mission (XRISM). XRISM is scheduled to be launched in the Japanese fiscal year 2022. Xtend consists of the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. The SXI uses the P-channel, back-illuminated type CCD with an imaging area size of 31 mm on a side. The four CCD chips are arranged in a 2$\times$2 grid and can be cooled down to $-120$ $^{\circ}$C with a single-stage Stirling cooler. The XMA nests thin aluminum foils coated with gold in a confocal way with an outer diameter of 45~cm. A pre-collimator is installed in front of the X-ray mirror for the reduction of the stray light. Combining the SXI and XMA with a focal length of 5.6m, a field of view of $38^{\prime}\times38^{\prime}$ over the energy range from 0.4 to 13 keV is realized. We have completed the fabrication of the flight model of both SXI and XMA. The performance verification has been successfully conducted in a series of sub-system level tests. We also carried out on-ground calibration measurements and the data analysis is ongoing.
△ Less
Submitted 13 March, 2023;
originally announced March 2023.
-
Experimental studies on the charge transfer inefficiency of CCD developed for the soft X-ray imaging telescope Xtend aboard the XRISM satellite
Authors:
Yoshiaki Kanemaru,
Jin Sato,
Toshiyuki Takaki,
Yuta Terada,
Koji Mori,
Mariko Saito,
Kumiko K. Nobukawa,
Takaaki Tanaka,
Hiroyuki Uchida,
Kiyoshi Hayashida,
Hironori Matsumoto,
Hirofumi Noda,
Maho Hanaoka,
Tomokage Yoneyama,
Koki Okazaki,
Kazunori Asakura,
Shotaro Sakuma,
Kengo Hattori,
Ayami Ishikura,
Yuki Amano,
Hiromichi Okon,
Takeshi G. Tsuru,
Hiroshi Tomida,
Hikari Kashimura,
Hiroshi Nakajima
, et al. (16 additional authors not shown)
Abstract:
We present experimental studies on the charge transfer inefficiency (CTI) of charge-coupled device (CCD) developed for the soft X-ray imaging telescope, Xtend, aboard the XRISM satellite. The CCD is equipped with a charge injection (CI) capability, in which sacrificial charge is periodically injected to fill the charge traps. By evaluating the re-emission of the trapped charge observed behind the…
▽ More
We present experimental studies on the charge transfer inefficiency (CTI) of charge-coupled device (CCD) developed for the soft X-ray imaging telescope, Xtend, aboard the XRISM satellite. The CCD is equipped with a charge injection (CI) capability, in which sacrificial charge is periodically injected to fill the charge traps. By evaluating the re-emission of the trapped charge observed behind the CI rows, we find that there are at least three trap populations with different time constants. The traps with the shortest time constant, which is equivalent to a transfer time of approximately one pixel, are mainly responsible for the trailing charge of an X-ray event seen in the following pixel. A comparison of the trailing charge in two clocking modes reveals that the CTI depends not only on the transfer time but also on the area, namely the imaging or storage area. We construct a new CTI model with taking into account with both transfer-time and area dependence. This model reproduces the data obtained in both clocking modes consistently. We also examine apparent flux dependence of the CTI observed without the CI technique. The higher incident X-ray flux is, the lower the CTI value becomes. It is due to a sacrificial charge effect by another X-ray photon. This effect is found to be negligible when the CI technique is used.
△ Less
Submitted 15 September, 2020; v1 submitted 14 September, 2020;
originally announced September 2020.
-
Optical Blocking Performance of CCDs Developed for the X-ray Astronomy Satellite XRISM
Authors:
Hiroyuki Uchida,
Takaaki Tanaka,
Yuki Amano,
Hiromichi Okon,
Takeshi G. Tsuru,
Hirofumi Noda,
Kiyoshi Hayashida,
Hironori Matsumoto,
Maho Hanaoka,
Tomokage Yoneyama,
Koki Okazaki,
Kazunori Asakura,
Shotaro Sakuma,
Kengo Hattori,
Ayami Ishikura,
Hiroshi Nakajima,
Mariko Saito,
Kumiko K. Nobukawa,
Hiroshi Tomida,
Yoshiaki Kanemaru,
Jin Sato,
Toshiyuki Takaki,
Yuta Terada,
Koji Mori,
Hikari Kashimura
, et al. (21 additional authors not shown)
Abstract:
We have been developing P-channel Charge-Coupled Devices (CCDs) for the upcoming X-ray Astronomy Satellite XRISM, planned to be launched in 2021. While the basic design of the CCD camera (Soft X-ray Imager: SXI) is almost the same as that of the lost Hitomi (ASTRO-H) observatory, we are planning to reduce the "light leakages" that is one of the largest problems recognized in Hitomi data. We adopte…
▽ More
We have been developing P-channel Charge-Coupled Devices (CCDs) for the upcoming X-ray Astronomy Satellite XRISM, planned to be launched in 2021. While the basic design of the CCD camera (Soft X-ray Imager: SXI) is almost the same as that of the lost Hitomi (ASTRO-H) observatory, we are planning to reduce the "light leakages" that is one of the largest problems recognized in Hitomi data. We adopted a double-layer optical blocking layer on the XRISM CCDs and also added an extra aluminum layer on the backside of them. We develop a newly designed test sample CCD and irradiate it with optical light to evaluate the optical blocking performance. As a result, light leakages are effectively reduced compared with that of the Hitomi CCDs. We thus conclude that the issue is solved by the new design and that the XRISM CCDs satisfy the mission requirement for the SXI.
△ Less
Submitted 16 July, 2020; v1 submitted 15 July, 2020;
originally announced July 2020.
-
Radiation hardness of a p-channel notch CCD developed for the X-ray CCD camera onboard the XRISM satellite
Authors:
Yoshiaki Kanemaru,
Jin Sato,
Koji Mori,
Hiroshi Nakajima,
Yusuke Nishioka,
Ayaki Takeda,
Kiyoshi Hayashida,
Hironori Matsumoto,
Junichi Iwagaki,
Koki Okazaki,
Kazunori Asakura,
Tomokage Yoneyama,
Hiroyuki Uchida,
Hiromichi Okon,
Takaaki Tanaka,
Takeshi G. Tsuru,
Hiroshi Tomida,
Takeo Shimoi,
Takayoshi Kohmura,
Kouichi Hagino,
Hiroshi Murakami,
Shogo B. Kobayashi,
Makoto Yamauchi,
Isamu Hatsukade,
Masayoshi Nobukawa
, et al. (8 additional authors not shown)
Abstract:
We report the radiation hardness of a p-channel CCD developed for the X-ray CCD camera onboard the XRISM satellite. This CCD has basically the same characteristics as the one used in the previous Hitomi satellite, but newly employs a notch structure of potential for signal charges by increasing the implant concentration in the channel. The new device was exposed up to approximately…
▽ More
We report the radiation hardness of a p-channel CCD developed for the X-ray CCD camera onboard the XRISM satellite. This CCD has basically the same characteristics as the one used in the previous Hitomi satellite, but newly employs a notch structure of potential for signal charges by increasing the implant concentration in the channel. The new device was exposed up to approximately $7.9 \times 10^{10} \mathrm{~protons~cm^{-2}}$ at 100 MeV. The charge transfer inefficiency was estimated as a function of proton fluence with an ${}^{55} \mathrm{Fe}$ source. A device without the notch structure was also examined for comparison. The result shows that the notch device has a significantly higher radiation hardness than those without the notch structure including the device adopted for Hitomi. This proves that the new CCD is radiation tolerant for space applications with a sufficient margin.
△ Less
Submitted 1 June, 2019;
originally announced June 2019.
-
Detection of polarized gamma-ray emission from the Crab nebula with Hitomi Soft Gamma-ray Detector
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (169 additional authors not shown)
Abstract:
We present the results from the Hitomi Soft Gamma-ray Detector (SGD) observation of the Crab nebula. The main part of SGD is a Compton camera, which in addition to being a spectrometer, is capable of measuring polarization of gamma-ray photons. The Crab nebula is one of the brightest X-ray / gamma-ray sources on the sky, and, the only source from which polarized X-ray photons have been detected. S…
▽ More
We present the results from the Hitomi Soft Gamma-ray Detector (SGD) observation of the Crab nebula. The main part of SGD is a Compton camera, which in addition to being a spectrometer, is capable of measuring polarization of gamma-ray photons. The Crab nebula is one of the brightest X-ray / gamma-ray sources on the sky, and, the only source from which polarized X-ray photons have been detected. SGD observed the Crab nebula during the initial test observation phase of Hitomi. We performed the data analysis of the SGD observation, the SGD background estimation and the SGD Monte Carlo simulations, and, successfully detected polarized gamma-ray emission from the Crab nebula with only about 5 ks exposure time. The obtained polarization fraction of the phase-integrated Crab emission (sum of pulsar and nebula emissions) is (22.1 $\pm$ 10.6)% and, the polarization angle is 110.7$^o$ + 13.2 / $-$13.0$^o$ in the energy range of 60--160 keV (The errors correspond to the 1 sigma deviation). The confidence level of the polarization detection was 99.3%. The polarization angle measured by SGD is about one sigma deviation with the projected spin axis of the pulsar, 124.0$^o$ $\pm$0.1$^o$.
△ Less
Submitted 1 October, 2018;
originally announced October 2018.
-
Hitomi X-ray Observation of the Pulsar Wind Nebula G21.5$-$0.9
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (173 additional authors not shown)
Abstract:
We present results from the Hitomi X-ray observation of a young composite-type supernova remnant (SNR) G21.5$-$0.9, whose emission is dominated by the pulsar wind nebula (PWN) contribution. The X-ray spectra in the 0.8-80 keV range obtained with the Soft X-ray Spectrometer (SXS), Soft X-ray Imager (SXI) and Hard X-ray Imager (HXI) show a significant break in the continuum as previously found with…
▽ More
We present results from the Hitomi X-ray observation of a young composite-type supernova remnant (SNR) G21.5$-$0.9, whose emission is dominated by the pulsar wind nebula (PWN) contribution. The X-ray spectra in the 0.8-80 keV range obtained with the Soft X-ray Spectrometer (SXS), Soft X-ray Imager (SXI) and Hard X-ray Imager (HXI) show a significant break in the continuum as previously found with the NuSTAR observation. After taking into account all known emissions from the SNR other than the PWN itself, we find that the Hitomi spectra can be fitted with a broken power law with photon indices of $Γ_1=1.74\pm0.02$ and $Γ_2=2.14\pm0.01$ below and above the break at $7.1\pm0.3$ keV, which is significantly lower than the NuSTAR result ($\sim9.0$ keV). The spectral break cannot be reproduced by time-dependent particle injection one-zone spectral energy distribution models, which strongly indicates that a more complex emission model is needed, as suggested by recent theoretical models. We also search for narrow emission or absorption lines with the SXS, and perform a timing analysis of PSR J1833$-$1034 with the HXI and SGD. No significant pulsation is found from the pulsar. However, unexpectedly, narrow absorption line features are detected in the SXS data at 4.2345 keV and 9.296 keV with a significance of 3.65 $σ$. While the origin of these features is not understood, their mere detection opens up a new field of research and was only possible with the high resolution, sensitivity and ability to measure extended sources provided by an X-ray microcalorimeter.
△ Less
Submitted 14 February, 2018;
originally announced February 2018.
-
Soft X-ray Imager aboard Hitomi (ASTRO-H)
Authors:
Takaaki Tanaka,
Hiroyuki Uchida,
Hiroshi Nakajima,
Hiroshi Tsunemi,
Kiyoshi Hayashida,
Takeshi G. Tsuru,
Tadayasu Dotani,
Ryo Nagino,
Shota Inoue,
Shohei Katada,
Ryosaku Washino,
Masanobu Ozaki,
Hiroshi Tomida,
Chikara Natsukari,
Shutaro Ueda,
Masachika Iwai,
Koji Mori,
Makoto Yamauchi,
Isamu Hatsukade,
Yusuke Nishioka,
Eri Isoda,
Masayoshi Nobukawa,
Junko S. Hiraga,
Takayoshi Kohmura,
Hiroshi Murakami
, et al. (3 additional authors not shown)
Abstract:
The Soft X-ray Imager (SXI) is an imaging spectrometer using charge-coupled devices (CCDs) aboard the Hitomi X-ray observatory. The SXI sensor has four CCDs with an imaging area size of $31~{\rm mm} \times 31~{\rm mm}$ arranged in a $2 \times 2$ array. Combined with the X-ray mirror, the Soft X-ray Telescope, the SXI detects X-rays between $0.4~{\rm keV}$ and $12~{\rm keV}$ and covers a…
▽ More
The Soft X-ray Imager (SXI) is an imaging spectrometer using charge-coupled devices (CCDs) aboard the Hitomi X-ray observatory. The SXI sensor has four CCDs with an imaging area size of $31~{\rm mm} \times 31~{\rm mm}$ arranged in a $2 \times 2$ array. Combined with the X-ray mirror, the Soft X-ray Telescope, the SXI detects X-rays between $0.4~{\rm keV}$ and $12~{\rm keV}$ and covers a $38^{\prime} \times 38^{\prime}$ field-of-view. The CCDs are P-channel fully-depleted, back-illumination type with a depletion layer thickness of $200~μ{\rm m}$. Low operation temperature down to $-120~^\circ{\rm C}$ as well as charge injection is employed to reduce the charge transfer inefficiency of the CCDs. The functionality and performance of the SXI are verified in on-ground tests. The energy resolution measured is $161$-$170~{\rm eV}$ in full width at half maximum for $5.9~{\rm keV}$ X-rays. In the tests, we found that the CTI of some regions are significantly higher. A method is developed to properly treat the position-dependent CTI. Another problem we found is pinholes in the Al coating on the incident surface of the CCDs for optical light blocking. The Al thickness of the contamination blocking filter is increased in order to sufficiently block optical light.
△ Less
Submitted 2 February, 2018; v1 submitted 21 January, 2018;
originally announced January 2018.
-
Temperature Structure in the Perseus Cluster Core Observed with Hitomi
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (170 additional authors not shown)
Abstract:
The present paper investigates the temperature structure of the X-ray emitting plasma in the core of the Perseus cluster using the 1.8--20.0 keV data obtained with the Soft X-ray Spectrometer (SXS) onboard the Hitomi Observatory. A series of four observations were carried out, with a total effective exposure time of 338 ks and covering a central region $\sim7'$ in diameter. The SXS was operated wi…
▽ More
The present paper investigates the temperature structure of the X-ray emitting plasma in the core of the Perseus cluster using the 1.8--20.0 keV data obtained with the Soft X-ray Spectrometer (SXS) onboard the Hitomi Observatory. A series of four observations were carried out, with a total effective exposure time of 338 ks and covering a central region $\sim7'$ in diameter. The SXS was operated with an energy resolution of $\sim$5 eV (full width at half maximum) at 5.9 keV. Not only fine structures of K-shell lines in He-like ions but also transitions from higher principal quantum numbers are clearly resolved from Si through Fe. This enables us to perform temperature diagnostics using the line ratios of Si, S, Ar, Ca, and Fe, and to provide the first direct measurement of the excitation temperature and ionization temperature in the Perseus cluster. The observed spectrum is roughly reproduced by a single temperature thermal plasma model in collisional ionization equilibrium, but detailed line ratio diagnostics reveal slight deviations from this approximation. In particular, the data exhibit an apparent trend of increasing ionization temperature with increasing atomic mass, as well as small differences between the ionization and excitation temperatures for Fe, the only element for which both temperatures can be measured. The best-fit two-temperature models suggest a combination of 3 and 5 keV gas, which is consistent with the idea that the observed small deviations from a single temperature approximation are due to the effects of projection of the known radial temperature gradient in the cluster core along the line of sight. Comparison with the Chandra/ACIS and the XMM-Newton/RGS results on the other hand suggests that additional lower-temperature components are present in the ICM but not detectable by Hitomi SXS given its 1.8--20 keV energy band.
△ Less
Submitted 18 December, 2017;
originally announced December 2017.
-
Atomic data and spectral modeling constraints from high-resolution X-ray observations of the Perseus cluster with Hitomi
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (170 additional authors not shown)
Abstract:
The Hitomi SXS spectrum of the Perseus cluster, with $\sim$5 eV resolution in the 2-9 keV band, offers an unprecedented benchmark of the atomic modeling and database for hot collisional plasmas. It reveals both successes and challenges of the current atomic codes. The latest versions of AtomDB/APEC (3.0.8), SPEX (3.03.00), and CHIANTI (8.0) all provide reasonable fits to the broad-band spectrum, a…
▽ More
The Hitomi SXS spectrum of the Perseus cluster, with $\sim$5 eV resolution in the 2-9 keV band, offers an unprecedented benchmark of the atomic modeling and database for hot collisional plasmas. It reveals both successes and challenges of the current atomic codes. The latest versions of AtomDB/APEC (3.0.8), SPEX (3.03.00), and CHIANTI (8.0) all provide reasonable fits to the broad-band spectrum, and are in close agreement on best-fit temperature, emission measure, and abundances of a few elements such as Ni. For the Fe abundance, the APEC and SPEX measurements differ by 16%, which is 17 times higher than the statistical uncertainty. This is mostly attributed to the differences in adopted collisional excitation and dielectronic recombination rates of the strongest emission lines. We further investigate and compare the sensitivity of the derived physical parameters to the astrophysical source modeling and instrumental effects. The Hitomi results show that an accurate atomic code is as important as the astrophysical modeling and instrumental calibration aspects. Substantial updates of atomic databases and targeted laboratory measurements are needed to get the current codes ready for the data from the next Hitomi-level mission.
△ Less
Submitted 14 December, 2017;
originally announced December 2017.
-
Hitomi Observations of the LMC SNR N132D: Highly Redshifted X-ray Emission from Iron Ejecta
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (169 additional authors not shown)
Abstract:
We present Hitomi observations of N132D, a young, X-ray bright, O-rich core-collapse supernova remnant in the Large Magellanic Cloud (LMC). Despite a very short observation of only 3.7 ks, the Soft X-ray Spectrometer (SXS) easily detects the line complexes of highly ionized S K and Fe K with 16-17 counts in each. The Fe feature is measured for the first time at high spectral resolution. Based on t…
▽ More
We present Hitomi observations of N132D, a young, X-ray bright, O-rich core-collapse supernova remnant in the Large Magellanic Cloud (LMC). Despite a very short observation of only 3.7 ks, the Soft X-ray Spectrometer (SXS) easily detects the line complexes of highly ionized S K and Fe K with 16-17 counts in each. The Fe feature is measured for the first time at high spectral resolution. Based on the plausible assumption that the Fe K emission is dominated by He-like ions, we find that the material responsible for this Fe emission is highly redshifted at ~800 km/s compared to the local LMC interstellar medium (ISM), with a 90% credible interval of 50-1500 km/s if a weakly informative prior is placed on possible line broadening. This indicates (1) that the Fe emission arises from the supernova ejecta, and (2) that these ejecta are highly asymmetric, since no blue-shifted component is found. The S K velocity is consistent with the local LMC ISM, and is likely from swept-up ISM material. These results are consistent with spatial mapping that shows the He-like Fe concentrated in the interior of the remnant and the S tracing the outer shell. The results also show that even with a very small number of counts, direct velocity measurements from Doppler-shifted lines detected in extended objects like supernova remnants are now possible. Thanks to the very low SXS background of ~1 event per spectral resolution element per 100 ks, such results are obtainable during short pointed or slew observations with similar instruments. This highlights the power of high-spectral-resolution imaging observations, and demonstrates the new window that has been opened with Hitomi and will be greatly widened with future missions such as the X-ray Astronomy Recovery Mission (XARM) and Athena.
△ Less
Submitted 6 December, 2017;
originally announced December 2017.
-
Glimpse of the highly obscured HMXB IGR J16318-4848 with Hitomi
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (169 additional authors not shown)
Abstract:
We report a Hitomi observation of IGR J16318-4848, a high-mass X-ray binary system with an extremely strong absorption of N_H~10^{24} cm^{-2}. Previous X-ray studies revealed that its spectrum is dominated by strong fluorescence lines of Fe as well as continuum emission. For physical and geometrical insight into the nature of the reprocessing material, we utilize the high spectroscopic resolving p…
▽ More
We report a Hitomi observation of IGR J16318-4848, a high-mass X-ray binary system with an extremely strong absorption of N_H~10^{24} cm^{-2}. Previous X-ray studies revealed that its spectrum is dominated by strong fluorescence lines of Fe as well as continuum emission. For physical and geometrical insight into the nature of the reprocessing material, we utilize the high spectroscopic resolving power of the X-ray microcalorimeter (the soft X-ray spectrometer; SXS) and the wide-band sensitivity by the soft and hard X-ray imager (SXI and HXI) aboard Hitomi. Even though photon counts are limited due to unintended off-axis pointing, the SXS spectrum resolves Fe K{α_1} and K{α_2} lines and puts strong constraints on the line centroid and width. The line width corresponds to the velocity of 160^{+300}_{-70} km s^{-1}. This represents the most accurate, and smallest, width measurement of this line made so far from any X-ray binary, much less than the Doppler broadening and shift expected from speeds which are characteristic of similar systems. Combined with the K-shell edge energy measured by the SXI and HXI spectra, the ionization state of Fe is estimated to be in the range of Fe I--IV. Considering the estimated ionization parameter and the distance between the X-ray source and the absorber, the density and thickness of the materials are estimated. The extraordinarily strong absorption and the absence of a Compton shoulder component is confirmed. These characteristics suggest reprocessing materials which are distributed in a narrow solid angle or scattering primarily with warm free electrons or neutral hydrogen.
△ Less
Submitted 21 November, 2017;
originally announced November 2017.
-
Hitomi Observation of Radio Galaxy NGC 1275: The First X-ray Microcalorimeter Spectroscopy of Fe-Kα Line Emission from an Active Galactic Nucleus
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (169 additional authors not shown)
Abstract:
The origin of the narrow Fe-Kα fluorescence line at 6.4 keV from active galactic nuclei has long been under debate; some of the possible sites are the outer accretion disk, the broad line region, a molecular torus, or interstellar/intracluster media. In February-March 2016, we performed the first X-ray microcalorimeter spectroscopy with the Soft X-ray Spectrometer (SXS) onboard the Hitomi satellit…
▽ More
The origin of the narrow Fe-Kα fluorescence line at 6.4 keV from active galactic nuclei has long been under debate; some of the possible sites are the outer accretion disk, the broad line region, a molecular torus, or interstellar/intracluster media. In February-March 2016, we performed the first X-ray microcalorimeter spectroscopy with the Soft X-ray Spectrometer (SXS) onboard the Hitomi satellite of the Fanaroff-Riley type I radio galaxy NGC 1275 at the center of the Perseus cluster of galaxies. With the high energy resolution of ~5 eV at 6 keV achieved by Hitomi/SXS, we detected the Fe-Kα line with ~5.4 σ significance. The velocity width is constrained to be 500-1600 km s$^{-1}$ (FWHM for Gaussian models) at 90% confidence. The SXS also constrains the continuum level from the NGC 1275 nucleus up to ~20 keV, giving an equivalent width ~20 eV of the 6.4 keV line. Because the velocity width is narrower than that of broad Hα line of ~2750 km s$^{-1}$, we can exclude a large contribution to the line flux from the accretion disk and the broad line region. Furthermore, we performed pixel map analyses on the Hitomi/SXS data and image analyses on the Chandra archival data, and revealed that the Fe-Kα line comes from a region within ~1.6 kpc from the NGC 1275 core, where an active galactic nucleus emission dominates, rather than that from intracluster media. Therefore, we suggest that the source of the Fe-Kα line from NGC 1275 is likely a low-covering fraction molecular torus or a rotating molecular disk which probably extends from a pc to hundreds pc scale in the active galactic nucleus system.
△ Less
Submitted 16 November, 2017;
originally announced November 2017.
-
Atmospheric gas dynamics in the Perseus cluster observed with Hitomi
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Rebecca E. A. Canning,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done
, et al. (173 additional authors not shown)
Abstract:
Extending the earlier measurements reported in Hitomi collaboration (2016, Nature, 535, 117), we examine the atmospheric gas motions within the central 100~kpc of the Perseus cluster using observations obtained with the Hitomi satellite. After correcting for the point spread function of the telescope and using optically thin emission lines, we find that the line-of-sight velocity dispersion of the…
▽ More
Extending the earlier measurements reported in Hitomi collaboration (2016, Nature, 535, 117), we examine the atmospheric gas motions within the central 100~kpc of the Perseus cluster using observations obtained with the Hitomi satellite. After correcting for the point spread function of the telescope and using optically thin emission lines, we find that the line-of-sight velocity dispersion of the hot gas is remarkably low and mostly uniform. The velocity dispersion reaches maxima of approximately 200~km~s$^{-1}$ toward the central active galactic nucleus (AGN) and toward the AGN inflated north-western `ghost' bubble. Elsewhere within the observed region, the velocity dispersion appears constant around 100~km~s$^{-1}$. We also detect a velocity gradient with a 100~km~s$^{-1}$ amplitude across the cluster core, consistent with large-scale sloshing of the core gas. If the observed gas motions are isotropic, the kinetic pressure support is less than 10\% of the thermal pressure support in the cluster core. The well-resolved optically thin emission lines have Gaussian shapes, indicating that the turbulent driving scale is likely below 100~kpc, which is consistent with the size of the AGN jet inflated bubbles. We also report the first measurement of the ion temperature in the intracluster medium, which we find to be consistent with the electron temperature. In addition, we present a new measurement of the redshift to the brightest cluster galaxy NGC~1275.
△ Less
Submitted 1 November, 2017;
originally announced November 2017.
-
Measurements of resonant scattering in the Perseus cluster core with Hitomi SXS
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Greg V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (170 additional authors not shown)
Abstract:
Thanks to its high spectral resolution (~5 eV at 6 keV), the Soft X-ray Spectrometer (SXS) on board Hitomi enables us to measure the detailed structure of spatially resolved emission lines from highly ionized ions in galaxy clusters for the first time. In this series of papers, using the SXS we have measured the velocities of gas motions, metallicities and the multi-temperature structure of the ga…
▽ More
Thanks to its high spectral resolution (~5 eV at 6 keV), the Soft X-ray Spectrometer (SXS) on board Hitomi enables us to measure the detailed structure of spatially resolved emission lines from highly ionized ions in galaxy clusters for the first time. In this series of papers, using the SXS we have measured the velocities of gas motions, metallicities and the multi-temperature structure of the gas in the core of the Perseus cluster. Here, we show that when inferring physical properties from line emissivities in systems like Perseus, the resonant scattering (RS) effect should be taken into account. In the Hitomi waveband, RS mostly affects the FeXXV He$α$ line ($w$) - the strongest line in the spectrum. The flux measured by Hitomi in this line is suppressed by a factor ~1.3 in the inner ~30 kpc, compared to predictions for an optically thin plasma; the suppression decreases with the distance from the center. The $w$ line also appears slightly broader than other lines from the same ion. The observed distortions of the $w$ line flux, shape and distance dependence are all consistent with the expected effect of the resonant scattering in the Perseus core. By measuring the ratio of fluxes in optically thick ($w$) and thin (FeXXV forbidden, He$β$, Ly$α$) lines, and comparing these ratios with predictions from Monte Carlo radiative transfer simulations, the velocities of gas motions have been obtained. The results are consistent with the direct measurements of gas velocities from line broadening described elsewhere in this series, although the systematic and statistical uncertainties remain significant. Further improvements in the predictions of line emissivities in plasma models, and deeper observations with future X-ray missions will enable RS measurements to provide powerful constraints on the amplitude and anisotropy of clusters gas motions.
△ Less
Submitted 11 October, 2017;
originally announced October 2017.
-
In-orbit performance of the soft X-ray imaging system aboard Hitomi (ASTRO-H)
Authors:
H. Nakajima,
Y. Maeda,
H. Uchida,
T. Tanaka,
H. Tsunemi,
K. Hayashida,
T. G. Tsuru,
T. Dotani,
R. Nagino,
S. Inoue,
M. Ozaki,
H. Tomida,
C. Natsukari,
S. Ueda,
K. Mori,
M. Yamauchi,
I. Hatsukade,
Y. Nishioka,
M. Sakata,
T. Beppu,
D. Honda,
M. Nobukawa,
J. S. Hiraga,
T. Kohmura,
H. Murakami
, et al. (24 additional authors not shown)
Abstract:
We describe the in-orbit performance of the soft X-ray imaging system consisting of the Soft X-ray Telescope and the Soft X-ray Imager aboard Hitomi. Verification and calibration of imaging and spectroscopic performance are carried out making the best use of the limited data of less than three weeks. Basic performance including a large field of view of 38'x38' is verified with the first light imag…
▽ More
We describe the in-orbit performance of the soft X-ray imaging system consisting of the Soft X-ray Telescope and the Soft X-ray Imager aboard Hitomi. Verification and calibration of imaging and spectroscopic performance are carried out making the best use of the limited data of less than three weeks. Basic performance including a large field of view of 38'x38' is verified with the first light image of the Perseus cluster of galaxies. Amongst the small number of observed targets, the on-minus-off pulse image for the out-of-time events of the Crab pulsar enables us to measure a half power diameter of the telescope as about 1.3'. The average energy resolution measured with the onboard calibration source events at 5.89 keV is 179 pm 3 eV in full width at half maximum. Light leak and cross talk issues affected the effective exposure time and the effective area, respectively, because all the observations were performed before optimizing an observation schedule and parameters for the dark level calculation. Screening the data affected by these two issues, we measure the background level to be 5.6x10^{-6} counts s^{-1} arcmin^{-2} cm^{-2} in the energy band of 5-12 keV, which is seven times lower than that of the Suzaku XIS-BI.
△ Less
Submitted 26 September, 2017;
originally announced September 2017.
-
Hitomi X-ray studies of Giant Radio Pulses from the Crab pulsar
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (179 additional authors not shown)
Abstract:
To search for giant X-ray pulses correlated with the giant radio pulses (GRPs) from the Crab pulsar, we performed a simultaneous observation of the Crab pulsar with the X-ray satellite Hitomi in the 2 -- 300 keV band and the Kashima NICT radio observatory in the 1.4 -- 1.7 GHz band with a net exposure of about 2 ks on 25 March 2016, just before the loss of the Hitomi mission.The timing performance…
▽ More
To search for giant X-ray pulses correlated with the giant radio pulses (GRPs) from the Crab pulsar, we performed a simultaneous observation of the Crab pulsar with the X-ray satellite Hitomi in the 2 -- 300 keV band and the Kashima NICT radio observatory in the 1.4 -- 1.7 GHz band with a net exposure of about 2 ks on 25 March 2016, just before the loss of the Hitomi mission.The timing performance of the Hitomi instruments was confirmed to meet the timing requirement and about 1,000 and 100 GRPs were simultaneously observed at the main and inter-pulse phases, respectively, and we found no apparent correlation between the giant radio pulses and the X-ray emission in either the main or inter-pulse phases.All variations are within the 2 sigma fluctuations of the X-ray fluxes at the pulse peaks, and the 3 sigma upper limits of variations of main- or inter- pulse GRPs are 22\% or 80\% of the peak flux in a 0.20 phase width, respectively, in the 2 -- 300 keV band.The values become 25\% or 110\% for main or inter-pulse GRPs, respectively, when the phase width is restricted into the 0.03 phase.Among the upper limits from the Hitomi satellite, those in the 4.5-10 keV and the 70-300 keV are obtained for the first time, and those in other bands are consistent with previous reports.Numerically, the upper limits of main- and inter-pulse GRPs in the 0.20 phase width are about (2.4 and 9.3) $\times 10^{-11}$ erg cm$^{-2}$, respectively. No significant variability in pulse profiles implies that the GRPs originated from a local place within the magnetosphere and the number of photon-emitting particles temporally increases.However, the results do not statistically rule out variations correlated with the GRPs, because the possible X-ray enhancement may appear due to a $>0.02$\% brightening of the pulse-peak flux under such conditions.
△ Less
Submitted 7 August, 2017; v1 submitted 27 July, 2017;
originally announced July 2017.
-
Search for Thermal X-ray Features from the Crab nebula with Hitomi Soft X-ray Spectrometer
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Greg V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (170 additional authors not shown)
Abstract:
The Crab nebula originated from a core-collapse supernova (SN) explosion observed in 1054 A.D. When viewed as a supernova remnant (SNR), it has an anomalously low observed ejecta mass and kinetic energy for an Fe-core collapse SN. Intensive searches were made for a massive shell that solves this discrepancy, but none has been detected. An alternative idea is that the SN1054 is an electron-capture…
▽ More
The Crab nebula originated from a core-collapse supernova (SN) explosion observed in 1054 A.D. When viewed as a supernova remnant (SNR), it has an anomalously low observed ejecta mass and kinetic energy for an Fe-core collapse SN. Intensive searches were made for a massive shell that solves this discrepancy, but none has been detected. An alternative idea is that the SN1054 is an electron-capture (EC) explosion with a lower explosion energy by an order of magnitude than Fe-core collapse SNe. In the X-rays, imaging searches were performed for the plasma emission from the shell in the Crab outskirts to set a stringent upper limit to the X-ray emitting mass. However, the extreme brightness of the source hampers access to its vicinity. We thus employed spectroscopic technique using the X-ray micro-calorimeter onboard the Hitomi satellite. By exploiting its superb energy resolution, we set an upper limit for emission or absorption features from yet undetected thermal plasma in the 2-12 keV range. We also re-evaluated the existing Chandra and XMM-Newton data. By assembling these results, a new upper limit was obtained for the X-ray plasma mass of <~ 1Mo for a wide range of assumed shell radius, size, and plasma temperature both in and out of the collisional equilibrium. To compare with the observation, we further performed hydrodynamic simulations of the Crab SNR for two SN models (Fe-core versus EC) under two SN environments (uniform ISM versus progenitor wind). We found that the observed mass limit can be compatible with both SN models if the SN environment has a low density of <~ 0.03 cm-3 (Fe core) or <~ 0.1 cm-3 (EC) for the uniform density, or a progenitor wind density somewhat less than that provided by a mass loss rate of 10-5 Mo yr-1 at 20 km s-1 for the wind environment.
△ Less
Submitted 4 July, 2017; v1 submitted 30 June, 2017;
originally announced July 2017.
-
Hitomi constraints on the 3.5 keV line in the Perseus galaxy cluster
Authors:
Hitomi Collaboration,
Felix A. Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Keith A. Arnaud,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger D. Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo Coppi,
Elisa Costantini,
Jelle de Plaa,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (193 additional authors not shown)
Abstract:
High-resolution X-ray spectroscopy with Hitomi was expected to resolve the origin of the faint unidentified E=3.5 keV emission line reported in several low-resolution studies of various massive systems, such as galaxies and clusters, including the Perseus cluster. We have analyzed the Hitomi first-light observation of the Perseus cluster. The emission line expected for Perseus based on the XMM-New…
▽ More
High-resolution X-ray spectroscopy with Hitomi was expected to resolve the origin of the faint unidentified E=3.5 keV emission line reported in several low-resolution studies of various massive systems, such as galaxies and clusters, including the Perseus cluster. We have analyzed the Hitomi first-light observation of the Perseus cluster. The emission line expected for Perseus based on the XMM-Newton signal from the large cluster sample under the dark matter decay scenario is too faint to be detectable in the Hitomi data. However, the previously reported 3.5 keV flux from Perseus was anomalously high compared to the sample-based prediction. We find no unidentified line at the reported high flux level. Taking into account the XMM measurement uncertainties for this region, the inconsistency with Hitomi is at a 99% significance for a broad dark-matter line and at 99.7% for a narrow line from the gas. We do not find anomalously high fluxes of the nearby faint K line or the Ar satellite line that were proposed as explanations for the earlier 3.5 keV detections. We do find a hint of a broad excess near the energies of high-n transitions of Sxvi (E=3.44 keV rest-frame) -- a possible signature of charge exchange in the molecular nebula and another proposed explanation for the unidentified line. While its energy is consistent with XMM pn detections, it is unlikely to explain the MOS signal. A confirmation of this interesting feature has to wait for a more sensitive observation with a future calorimeter experiment.
△ Less
Submitted 27 February, 2017; v1 submitted 25 July, 2016;
originally announced July 2016.
-
The Quiescent Intracluster Medium in the Core of the Perseus Cluster
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Naohisa Anabuki,
Lorella Angelini,
Keith Arnaud,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall Bautz,
Roger Blandford,
Laura Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward Cackett,
Maria Chernyakova,
Meng Chiao,
Paolo Coppi,
Elisa Costantini,
Jelle de Plaa,
Jan-Willem den Herder,
Chris Done
, et al. (191 additional authors not shown)
Abstract:
Clusters of galaxies are the most massive gravitationally-bound objects in the Universe and are still forming. They are thus important probes of cosmological parameters and a host of astrophysical processes. Knowledge of the dynamics of the pervasive hot gas, which dominates in mass over stars in a cluster, is a crucial missing ingredient. It can enable new insights into mechanical energy injectio…
▽ More
Clusters of galaxies are the most massive gravitationally-bound objects in the Universe and are still forming. They are thus important probes of cosmological parameters and a host of astrophysical processes. Knowledge of the dynamics of the pervasive hot gas, which dominates in mass over stars in a cluster, is a crucial missing ingredient. It can enable new insights into mechanical energy injection by the central supermassive black hole and the use of hydrostatic equilibrium for the determination of cluster masses. X-rays from the core of the Perseus cluster are emitted by the 50 million K diffuse hot plasma filling its gravitational potential well. The Active Galactic Nucleus of the central galaxy NGC1275 is pumping jetted energy into the surrounding intracluster medium, creating buoyant bubbles filled with relativistic plasma. These likely induce motions in the intracluster medium and heat the inner gas preventing runaway radiative cooling; a process known as Active Galactic Nucleus Feedback. Here we report on Hitomi X-ray observations of the Perseus cluster core, which reveal a remarkably quiescent atmosphere where the gas has a line-of-sight velocity dispersion of 164+/-10 km/s in a region 30-60 kpc from the central nucleus. A gradient in the line-of-sight velocity of 150+/-70 km/s is found across the 60 kpc image of the cluster core. Turbulent pressure support in the gas is 4% or less of the thermodynamic pressure, with large scale shear at most doubling that estimate. We infer that total cluster masses determined from hydrostatic equilibrium in the central regions need little correction for turbulent pressure.
△ Less
Submitted 15 July, 2016;
originally announced July 2016.
-
The ASTRO-H X-ray Astronomy Satellite
Authors:
Tadayuki Takahashi,
Kazuhisa Mitsuda,
Richard Kelley,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steve Allen,
Naohisa Anabuki,
Lorella Angelini,
Keith Arnaud,
Makoto Asai,
Marc Audard,
Hisamitsu Awaki,
Philipp Azzarello,
Chris Baluta,
Aya Bamba,
Nobutaka Bando,
Marshall Bautz,
Thomas Bialas,
Roger Blandford,
Kevin Boyce,
Laura Brenneman,
Greg Brown,
Edward Cackett,
Edgar Canavan
, et al. (228 additional authors not shown)
Abstract:
The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions developed by the Institute of Space and Astronautical Science (ISAS), with a planned launch in 2015. The ASTRO-H mission is equipped with a suite of sensitive instruments with the highest energy resolution ever achieved at E > 3 keV and a wide energy range spanning four decades in energy from soft X-ra…
▽ More
The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions developed by the Institute of Space and Astronautical Science (ISAS), with a planned launch in 2015. The ASTRO-H mission is equipped with a suite of sensitive instruments with the highest energy resolution ever achieved at E > 3 keV and a wide energy range spanning four decades in energy from soft X-rays to gamma-rays. The simultaneous broad band pass, coupled with the high spectral resolution of Delta E < 7 eV of the micro-calorimeter, will enable a wide variety of important science themes to be pursued. ASTRO-H is expected to provide breakthrough results in scientific areas as diverse as the large-scale structure of the Universe and its evolution, the behavior of matter in the gravitational strong field regime, the physical conditions in sites of cosmic-ray acceleration, and the distribution of dark matter in galaxy clusters at different redshifts.
△ Less
Submitted 3 December, 2014;
originally announced December 2014.
-
The ASTRO-H X-ray Observatory
Authors:
Tadayuki Takahashi,
Kazuhisa Mitsuda,
Richard Kelley,
Henri AartsFelix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steve Allen,
Naohisa Anabuki,
Lorella Angelini,
Keith Arnaud,
Makoto Asai,
Marc Audard,
Hisamitsu Awaki,
Philipp Azzarello,
Chris Baluta,
Aya Bamba,
Nobutaka Bando,
Mark Bautz,
Roger Blandford,
Kevin Boyce,
Greg Brown,
Ed Cackett,
Maria Chernyakova,
Paolo Coppi,
Elisa Costantini
, et al. (198 additional authors not shown)
Abstract:
The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions initiated by the Institute of Space and Astronautical Science (ISAS). ASTRO-H will investigate the physics of the high-energy universe via a suite of four instruments, covering a very wide energy range, from 0.3 keV to 600 keV. These instruments include a high-resolution, high-throughput spectrometer s…
▽ More
The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions initiated by the Institute of Space and Astronautical Science (ISAS). ASTRO-H will investigate the physics of the high-energy universe via a suite of four instruments, covering a very wide energy range, from 0.3 keV to 600 keV. These instruments include a high-resolution, high-throughput spectrometer sensitive over 0.3-2 keV with high spectral resolution of Delta E < 7 eV, enabled by a micro-calorimeter array located in the focal plane of thin-foil X-ray optics; hard X-ray imaging spectrometers covering 5-80 keV, located in the focal plane of multilayer-coated, focusing hard X-ray mirrors; a wide-field imaging spectrometer sensitive over 0.4-12 keV, with an X-ray CCD camera in the focal plane of a soft X-ray telescope; and a non-focusing Compton-camera type soft gamma-ray detector, sensitive in the 40-600 keV band. The simultaneous broad bandpass, coupled with high spectral resolution, will enable the pursuit of a wide variety of important science themes.
△ Less
Submitted 16 October, 2012;
originally announced October 2012.
-
The ASTRO-H Mission
Authors:
Tadayuki Takahashi,
Kazuhisa Mitsuda,
Richard Kelley,
Felix Aharonian,
Fumie Akimoto,
Steve Allen,
Naohisa Anabuki,
Lorella Angelini,
Keith Arnaud,
Hisamitsu Awaki,
Aya Bamba,
Nobutaka Bando,
Mark Bautz,
Roger Blandford,
Kevin Boyce,
Greg Brown,
Maria Chernyakova,
Paolo Coppi,
Elisa Costantini,
Jean Cottam,
John Crow,
Jelle de Plaa,
Cor de Vries,
Jan-Willem den Herder,
Michael DiPirro
, et al. (152 additional authors not shown)
Abstract:
The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions initiated by the Institute of Space and Astronautical Science (ISAS). ASTRO-H will investigate the physics of the high-energy universe by performing high-resolution, high-throughput spectroscopy with moderate angular resolution. ASTRO-H covers very wide energy range from 0.3 keV to 600 keV. ASTRO-H all…
▽ More
The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions initiated by the Institute of Space and Astronautical Science (ISAS). ASTRO-H will investigate the physics of the high-energy universe by performing high-resolution, high-throughput spectroscopy with moderate angular resolution. ASTRO-H covers very wide energy range from 0.3 keV to 600 keV. ASTRO-H allows a combination of wide band X-ray spectroscopy (5-80 keV) provided by multilayer coating, focusing hard X-ray mirrors and hard X-ray imaging detectors, and high energy-resolution soft X-ray spectroscopy (0.3-12 keV) provided by thin-foil X-ray optics and a micro-calorimeter array. The mission will also carry an X-ray CCD camera as a focal plane detector for a soft X-ray telescope (0.4-12 keV) and a non-focusing soft gamma-ray detector (40-600 keV) . The micro-calorimeter system is developed by an international collaboration led by ISAS/JAXA and NASA. The simultaneous broad bandpass, coupled with high spectral resolution of Delta E ~7 eV provided by the micro-calorimeter will enable a wide variety of important science themes to be pursued.
△ Less
Submitted 24 October, 2010;
originally announced October 2010.
-
HETE-2 Observations of the X-Ray Flash XRF 040916
Authors:
Makoto Arimoto,
Nobuyuki Kawai,
Atsumasa Yoshida,
Toru Tamagawa,
Yuji Shirasaki,
Motoko Suzuki,
Masaru Matsuoka,
Jun'ichi Kotoku,
Rie Sato,
Takashi Shimokawabe,
Nicolas Vasquez Pazmino,
Takuto Ishimura,
Yujin Nakagawa,
Nobuyuki Ishikawa,
Akina Kobayashi,
Satoshi Sugita,
Ichiro Takahashi,
Makoto Kuwahara,
Makoto Yamauchi,
Kunio Takagishi,
Isamu Hatsukade,
Jean-Luc Atteia,
Alexandre Pelangeon,
Roland Vanderspek,
Carlo Graziani
, et al. (21 additional authors not shown)
Abstract:
A long X-ray flash was detected and localized by the instruments aboard the High Energy Transient Explorer II (HETE-2) at 00:03:30 UT on 2004 September 16. The position was reported to the GRB Coordinates Network (GCN) approximately 2 hours after the burst. This burst consists of two peaks separated by 200 s, with durations of 110 s and 60 s. We have analyzed the energy spectra of the 1st and 2n…
▽ More
A long X-ray flash was detected and localized by the instruments aboard the High Energy Transient Explorer II (HETE-2) at 00:03:30 UT on 2004 September 16. The position was reported to the GRB Coordinates Network (GCN) approximately 2 hours after the burst. This burst consists of two peaks separated by 200 s, with durations of 110 s and 60 s. We have analyzed the energy spectra of the 1st and 2nd peaks observed with the Wide Field X-Ray Monitor (WXM) and the French Gamma Telescope (FREGATE). We discuss the origin of the 2nd peak in terms of flux variabilities and timescales. We find that it is most likely part of the prompt emission, and is explained by the long-acting engine model. This feature is similar to some bright X-ray flares detected in the early afterglow phase of bursts observed by the Swift satellite.
△ Less
Submitted 7 March, 2007; v1 submitted 2 March, 2007;
originally announced March 2007.
-
An Optically Dark GRB Observed by HETE-2: GRB 051022
Authors:
Yujin E. Nakagawa,
Atsumasa Yoshida,
Satoshi Sugita,
Kaoru Tanaka,
Nobuyuki Ishikawa,
Toru Tamagawa,
Motoko Suzuki,
Yuji Shirasaki,
Nobuyuki Kawai,
Masaru Matsuoka,
Jean-Luc Atteia,
Alexandre Pelangeon,
Roland Vanderspek,
Geoff B. Crew,
Joel S. Villasenor,
Nat Butler,
John Doty,
George R. Ricker,
Graziella Pizzichini,
Timothy Q. Donaghy,
Donald Q. Lamb,
Carlo Graziani,
Rie Sato,
Miki Maetou,
Makoto Arimoto
, et al. (11 additional authors not shown)
Abstract:
GRB 051022 was detected at 13:07:58 on 22 October 2005 by HETE-2. The location of GRB 051022 was determined immediately by the flight localization system. This burst contains multiple pulses and has a rather long duration of about 190 seconds. The detections of candidate X-ray and radio afterglows were reported, whereas no optical afterglow was found. The optical spectroscopic observations of th…
▽ More
GRB 051022 was detected at 13:07:58 on 22 October 2005 by HETE-2. The location of GRB 051022 was determined immediately by the flight localization system. This burst contains multiple pulses and has a rather long duration of about 190 seconds. The detections of candidate X-ray and radio afterglows were reported, whereas no optical afterglow was found. The optical spectroscopic observations of the host galaxy revealed the redshift z = 0.8. Using the data derived by HETE-2 observation of the prompt emission, we found the absorption N_H = 8.8 -2.9/+3.1 x 10^22 cm^-2 and the visual extinction A_V = 49 -16/+17 mag in the host galaxy. If this is the case, no detection of any optical transient would be quite reasonable. The absorption derived by the Swift XRT observations of the afterglow is fully consistent with those obtained from the early HETE-2 observation of the prompt emission. Our analysis implies an interpretation that the absorbing medium could be outside external shock at R ~ 10^16 cm, which may be a dusty molecular cloud.
△ Less
Submitted 6 July, 2006; v1 submitted 17 May, 2006;
originally announced May 2006.
-
Design and Performance of the Wide-Field X-Ray Monitor on Board the High-Energy Transient Explorer 2
Authors:
Y. Shirasaki,
N. Kawai,
A. Yoshida,
M. Matsuoka,
T. Tamagawa,
K. Torii,
T. Sakamoto,
M. Suzuki,
Y. Urata,
R. Sato,
Y. Nakagawa,
D. Takahashi,
E. E. Fenimore,
M. Galassi,
D. Q. Lamb,
C. Graziani,
T. Q. Donaghy,
R. Vanderspek,
M. Yamauchi,
K. Takagishi,
I. Hatsukade
Abstract:
The Wide-field X-ray Monitor (WXM) is one of the scientific instruments carried on the High Energy Transient Explorer 2 (HETE-2) satellite launched on 2000 October 9. HETE-2 is an international mission consisting of a small satellite dedicated to provide broad-band observations and accurate localizations of gamma-ray bursts (GRBs). A unique feature of this mission is its capability to determine…
▽ More
The Wide-field X-ray Monitor (WXM) is one of the scientific instruments carried on the High Energy Transient Explorer 2 (HETE-2) satellite launched on 2000 October 9. HETE-2 is an international mission consisting of a small satellite dedicated to provide broad-band observations and accurate localizations of gamma-ray bursts (GRBs). A unique feature of this mission is its capability to determine and transmit GRB coordinates in almost real-time through the burst alert network. The WXM consists of three elements: four identical Xe-filled one-dimensional position-sensitive proportional counters, two sets of one-dimensional coded apertures, and the main electronics. The WXM counters are sensitive to X-rays between 2 keV and 25 keV within a field-of-view of about 1.5 sr, with a total detector area of about 350 cm$^2$. The in-flight triggering and localization capability can produce a real-time GRB location of several to 30 arcmin accuracy, with a limiting sensitivity of $10^{-7}$ erg cm$^{-2}$. In this report, the details of the mechanical structure, electronics, on-board software, ground and in-flight calibration, and in-flight performance of the WXM are discussed.
△ Less
Submitted 3 November, 2003;
originally announced November 2003.
-
H0 from an orientation-unbiased sample of SZ and X-ray clusters
Authors:
Michael E. Jones,
Alastair C. Edge,
Keith Grainge,
William F. Grainger,
Ruediger Kneissl,
G. G. Pooley,
Richard Saunders,
Shigeru J. Miyoshi,
Taisuke Tsuruta,
Koujun Yamashita,
Yuzuru Tawara,
Akihiro Furuzawa,
Akihiro Harada,
Isamu Hatsukade
Abstract:
We have observed the Sunyaev-Zel'dovich effect in a sample of five moderate-redshift clusters with the Ryle Telescope, and used them in conjunction with X-ray imaging and spectral data from ROSAT and ASCA to measure the Hubble constant. This sample was chosen with a strict X-ray flux limit using both the BCS and NORAS cluster catalogues to be well above the surface-brightness limit of the ROSAT…
▽ More
We have observed the Sunyaev-Zel'dovich effect in a sample of five moderate-redshift clusters with the Ryle Telescope, and used them in conjunction with X-ray imaging and spectral data from ROSAT and ASCA to measure the Hubble constant. This sample was chosen with a strict X-ray flux limit using both the BCS and NORAS cluster catalogues to be well above the surface-brightness limit of the ROSAT All-Sky Survey, and hence to be unbiased with respect to the orientation of the cluster. This controls the major potential systematic effect in the SZ/X-ray method of measureing H0. Taking the weighted geometric mean of the results and including the main sources of random error, namely the noise in the SZ measurement, the uncertainty in the X-ray temperatures and the unknown ellipticity of the clusters, we find H0 = 59 +8/-7 km/s/Mpc assuming a standard CDM model with Omega_M = 1.0, Omega_Lambda = 0.0, or H0 = 65 +8/-7 km/s/Mpc if Omega_M = 0.3, Omega_Lambda = 0.7.
△ Less
Submitted 2 March, 2001;
originally announced March 2001.
-
A measurement of H_0 from Ryle Telescope, ASCA and ROSAT observations of Abell 773
Authors:
Richard Saunders,
Ruediger Kneissl,
Keith Grainge,
William F. Grainger,
Michael E. Jones,
Alessia Maggi,
Rhiju Das,
Alastair Edge,
A. N. Lasenby,
G. G. Pooley,
Shigeru J. Miyoshi,
Taisuke Tsuruta,
Koujun Yamashita,
Yuzuru Tawara,
Akihiro Furuzawa,
Akihiro Harada,
Izamu Hatsukade
Abstract:
We present new Ryle Telescope (RT) observations of the Sunyaev Zel'dovich (SZ) decrement from the cluster Abell 773. The field contains a number of faint radio sources that required careful subtraction. We use ASCA observations to measure the gas temperature and a ROSAT HRI image to model the gas distribution. Normalising the gas distribution to fit the RT visibilities returns a value of H_0 of…
▽ More
We present new Ryle Telescope (RT) observations of the Sunyaev Zel'dovich (SZ) decrement from the cluster Abell 773. The field contains a number of faint radio sources that required careful subtraction. We use ASCA observations to measure the gas temperature and a ROSAT HRI image to model the gas distribution. Normalising the gas distribution to fit the RT visibilities returns a value of H_0 of 77 (+19,-15) km/s/Mpc (1-sigma errors) for an Einstein-de-Sitter universe, or 85 (+20,-17) km/s/Mpc for a flat model with Omega_Lambda = 0.7. The errors quoted include estimates of the effects of the principal errors: noise in the SZ measurement, gas temperature uncertainty, and line-of sight depth uncertainty.
△ Less
Submitted 10 March, 2003; v1 submitted 13 April, 1999;
originally announced April 1999.
-
Abundance Gradients in Cooling Flow Clusters: Ginga Lac & Einstein SSS Spectra of A496, A1795, A2142 & A2199
Authors:
Raymond E. White III,
C. S. R. Day,
Isamu Hatsukade,
John P. Hughes
Abstract:
We analyze the Ginga LAC and Einstein SSS spectra of four cooling flow clusters, A496, A1795, A2142 and A2199, each of which shows firm evidence of a relatively cool component. The inclusion of such cool spectral components in joint fits of SSS and LAC data leads to somewhat higher global temperatures than are derived from the high energy LAC data alone. We find little evidence of cool emission…
▽ More
We analyze the Ginga LAC and Einstein SSS spectra of four cooling flow clusters, A496, A1795, A2142 and A2199, each of which shows firm evidence of a relatively cool component. The inclusion of such cool spectral components in joint fits of SSS and LAC data leads to somewhat higher global temperatures than are derived from the high energy LAC data alone. We find little evidence of cool emission outside the SSS field of view. Metal abundances appear to be centrally enhanced in all four cluster, with varying degrees of model dependence and statistical significance: the evidence is statistically strongest for A496 and A2142, somewhat weaker for A2199 and weakest for A1795. We also explore the model-dependence in the amount of cold, X-ray absorbing matter discovered in these clusters by White et al. (1991).
△ Less
Submitted 26 April, 1994;
originally announced April 1994.