Measurement of the $^{159}$Tb(n, $γ$) cross section at the CSNS Back-n facility
Authors:
S. Zhang,
G. Li,
W. Jiang,
D. X. Wang,
J. Ren,
E. T. Li,
M. Huang,
J. Y. Tang,
X. C. Ruan,
H. W. Wang,
Z. H. Li,
Y. S. Chen,
L. X. Liu,
X. X. Li,
Q. W. Fan,
R. R. Fan,
X. R. Hu,
J. C. Wang,
X. Li,
1D. D. Niu,
N. Song,
M. Gu
Abstract:
The stellar (n, $γ$) cross section data for the mass numbers around A $\approx$ 160 are of key importance to nucleosynthesis in the main component of the slow neutron capture process, which occur in the thermally pulsing asymptotic giant branch (TP--AGB). The new measurement of (n, $γ$) cross sections for $^{159}$Tb was performed using the C$_6$D$_6$ detector system at the back streaming white neu…
▽ More
The stellar (n, $γ$) cross section data for the mass numbers around A $\approx$ 160 are of key importance to nucleosynthesis in the main component of the slow neutron capture process, which occur in the thermally pulsing asymptotic giant branch (TP--AGB). The new measurement of (n, $γ$) cross sections for $^{159}$Tb was performed using the C$_6$D$_6$ detector system at the back streaming white neutron beam line (Back-n) of the China spallation neutron source (CSNS) with neutron energies ranging from 1 eV to 1 MeV. Experimental resonance capture kernels were reported up to 1.2 keV neutron energy with this capture measurement. Maxwellian-averaged cross sections (MACS) were derived from the measured $^{159}$Tb (n, $γ$) cross sections at $kT$ = 5 $\sim$ 100 keV and are in good agreement with the recommended data of KADoNiS-v0.3 and JEFF-3.3, while KADoNiS-v1.0 and ENDF-VIII.0 significantly overestimate the present MACS up to 40$\%$ and 20$\%$, respectively. A sensitive test of the s-process nucleosynthesis was also performed with the stellar evolution code MESA. Significant changes in abundances around A $\approx$ 160 were observed between the ENDF/B-VIII.0 and present measured rate of $^{159}$Tb(n, $γ$)$^{160}$Tb in the MESA simulation.
△ Less
Submitted 4 December, 2022;
originally announced December 2022.
-
The $^{59}$Fe(n, γ)$^{60}$Fe Cross Section from the Surrogate Ratio Method and Its Effect on the $^{60}$Fe Nucleosynthesis
Authors:
S. Q. Yan,
X. Y. Li,
K. Nishio,
M. Lugaro,
Z. H. Li,
H. Makii,
M. Pignatari,
Y. B. Wang,
R. Orlandi,
K. Hirose,
K. Tsukada,
P. Mohr,
G. S. Li,
J. G. Wang,
B. S. Gao,
Y. L. Han,
B. Guo,
Y. J. Li,
Y. P. Shen,
T. K. Sato,
Y. Ito,
F. Suzaki,
J. Su,
Y. Y. Yang,
J. S. Wang
, et al. (17 additional authors not shown)
Abstract:
The long-lived $^{60}$Fe (with a half-life of 2.62 Myr) is a crucial diagnostic of active nucleosynthesis in the Milky Way galaxy and in supernovae near the solar system. The neutron-capture reaction $^{59}$Fe(n,$γ$)$^{60}$Fe on $^{59}$Fe (half-life = 44.5 days) is the key reaction for the production of $^{60}$Fe in massive stars. This reaction cross section has been previously constrained by the…
▽ More
The long-lived $^{60}$Fe (with a half-life of 2.62 Myr) is a crucial diagnostic of active nucleosynthesis in the Milky Way galaxy and in supernovae near the solar system. The neutron-capture reaction $^{59}$Fe(n,$γ$)$^{60}$Fe on $^{59}$Fe (half-life = 44.5 days) is the key reaction for the production of $^{60}$Fe in massive stars. This reaction cross section has been previously constrained by the Coulomb dissociation experiment, which offered partial constraint on the $E$1 $γ$-ray strength function but a negligible constraint on the $M$1 and $E$2 components. In this work, for the first time, we use the surrogate ratio method to experimentally determine the $^{59}$Fe(n,$γ$)$^{60}$Fe cross sections in which all the components are included. We derived a Maxwellian-averaged cross section of 27.5 $\pm$ 3.5 mb at $kT$= 30 keV and 13.4 $\pm$ 1.7 mb at $kT$= 90 keV, roughly 10 - 20% higher than previous estimates. We analyzed the impact of our new reaction rates in nucleosynthesis models of massive stars and found that uncertainties in the production of $^{60}$Fe from the $^{59}$Fe(n,$γ$)$^{60}$Fe rate are at most of 25%. We conclude that stellar physics uncertainties now play a major role in the accurate evaluation of the stellar production of $^{60}$Fe.
△ Less
Submitted 26 September, 2021;
originally announced September 2021.
-
Progress in Nuclear Astrophysics of East and Southeast Asia
Authors:
Azni Abdul Aziz,
Nor Sofiah Ahmad,
S. Ahn,
Wako Aoki,
Muruthujaya Bhuyan,
Ke-Jung Chen,
Gang Guo,
K. I. Hahn,
Toshitaka Kajino,
Hasan Abu Kassim,
D. Kim,
Shigeru Kubono,
Motohiko Kusakabe,
A. Li,
Haining Li,
Z. H. Li,
W. P. Liu,
Z. W. Liu,
Tohru Motobayashi,
Kuo-Chuan Pan,
T. -S. Park,
Jian-Rong Shi,
Xiaodong Tang,
W. Wang,
Liangjian Wen
, et al. (3 additional authors not shown)
Abstract:
Nuclear astrophysics is an interdisciplinary research field of nuclear physics and astrophysics, seeking for the answer to a question, how to understand the evolution of the Universe with the nuclear processes which we learn. We review the research activities of nuclear astrophysics in east and southeast Asia which includes astronomy, experimental and theoretical nuclear physics and astrophysics.…
▽ More
Nuclear astrophysics is an interdisciplinary research field of nuclear physics and astrophysics, seeking for the answer to a question, how to understand the evolution of the Universe with the nuclear processes which we learn. We review the research activities of nuclear astrophysics in east and southeast Asia which includes astronomy, experimental and theoretical nuclear physics and astrophysics. Several hot topics such as the Li problems, critical nuclear reactions and properties in stars, properties of dense matter, r-process nucleosynthesis and $ν$-process nucleosynthesis are chosen and discussed in further details. Some future Asian facilities, together with physics perspectives, are introduced.
△ Less
Submitted 9 August, 2021;
originally announced August 2021.
-
Time-Resolved GRB Polarization with POLAR and GBM
Authors:
J. Michael Burgess,
M. Kole,
F. Berlato,
J. Greiner,
G. Vianello,
N. Produit,
Z. H Li,
J. C Sun
Abstract:
Simultaneous $γ$-ray measurements of gamma-ray burst (GRB) spectra and polarization offer a unique way to determine the underlying emission mechanism(s) in these objects as well as probing the particle acceleration mechanism(s) that lead to the observed $γ$-ray emission. Herein we examine the jointly-observed data from POLAR and GBM of GRB 170114A to determine its spectral and polarization propert…
▽ More
Simultaneous $γ$-ray measurements of gamma-ray burst (GRB) spectra and polarization offer a unique way to determine the underlying emission mechanism(s) in these objects as well as probing the particle acceleration mechanism(s) that lead to the observed $γ$-ray emission. Herein we examine the jointly-observed data from POLAR and GBM of GRB 170114A to determine its spectral and polarization properties and seek to understand the emission processes that generate these observations. We aim to develop an extensible and statistically sound framework for these types of measurements applicable to other instruments. We leverage the existing 3ML analysis framework to develop a new analysis pipeline for simultaneously modeling the spectral and polarization data. We derive the proper Poisson likelihood for $γ$-ray polarization measurements in the presence of background. The developed framework is publicly available for similar measurements with other $γ$-ray polarimeters. The data are analyzed within a Bayesian probabilistic context and the spectral data from both instruments are simultaneously modeled with a physical, numerical synchrotron code. The spectral modeling of the data is consistent with a synchrotron photon model as has been found in a majority of similarly analyzed single-pulse GRBs. The polarization results reveal a slight trend of growing polarization in time reaching values of ~30% at the temporal peak of the emission. Additionally, it is observed that the polarization angle evolves with time throughout the emission. These results hint at a synchrotron origin of the emission but further observations of many GRBs are required to verify these evolutionary trends. Furthermore, we encourage the development of time-resolved polarization models for the prompt emission of GRBs as the current models are not predictive enough to enable a full modeling of our current data.
△ Less
Submitted 12 August, 2019; v1 submitted 15 January, 2019;
originally announced January 2019.
-
Instrument Performance and Simulation Verification of the POLAR Detector
Authors:
M. Kole,
Z. H. Li,
N. Produit,
T. Tymieniecka,
J. Zhang,
A. Zwolinska,
T. W. Bao,
T. Bernasconi,
F. Cadoux,
M. Z. Feng,
N. Gauvin,
W. Hajdas,
S. W. Kong,
H. C. Li,
L. Li,
X. Liu,
R. Marcinkowski,
S. Orsi,
M. Pohl,
D. Rybka,
J. C. Sun,
L. M. Song,
J. Szabelski,
R. J. Wang,
Y. H. Wang
, et al. (10 additional authors not shown)
Abstract:
POLAR is a new satellite-born detector aiming to measure the polarization of an unprecedented number of Gamma-Ray Bursts in the 50-500 keV energy range. The instrument, launched on-board the Tiangong-2 Chinese Space lab on the 15th of September 2016, is designed to measure the polarization of the hard X-ray flux by measuring the distribution of the azimuthal scattering angles of the incoming photo…
▽ More
POLAR is a new satellite-born detector aiming to measure the polarization of an unprecedented number of Gamma-Ray Bursts in the 50-500 keV energy range. The instrument, launched on-board the Tiangong-2 Chinese Space lab on the 15th of September 2016, is designed to measure the polarization of the hard X-ray flux by measuring the distribution of the azimuthal scattering angles of the incoming photons. A detailed understanding of the polarimeter and specifically of the systematic effects induced by the instrument's non-uniformity are required for this purpose. In order to study the instrument's response to polarization, POLAR underwent a beam test at the European Synchrotron Radiation Facility in France. In this paper both the beam test and the instrument performance will be described. This is followed by an overview of the Monte Carlo simulation tools developed for the instrument. Finally a comparison of the measured and simulated instrument performance will be provided and the instrument response to polarization will be presented.
△ Less
Submitted 2 August, 2017;
originally announced August 2017.
-
Calibration of the Space-borne Compton Polarimeter POLAR flight model with 100% polarized X-ray beams
Authors:
H. L. Xiao,
W. Hajdas,
P. Socha,
R. Marcinkowski,
B. B. Wu,
T. W. Bao,
J. Y. Chai,
Y. W. Dong,
M. N. Kong,
L. Li,
Z. H. Li,
J. T. Liu,
H. L. Shi,
L. M. Song,
J. C. Sun,
R. J. Wang,
Y. H. Wang,
X. Wen,
S. L. Xiong,
J. Zhang,
L. Y. Zhang,
S. N. Zhang,
X. F. Zhang,
Y. J. Zhang,
F. Cadoux
, et al. (10 additional authors not shown)
Abstract:
POLAR is space-borne detector designed for a precise measurement of gamma-ray polarization of the prompt emissions of Gamma-Ray Bursts in the energy range 50 keV - 500 keV. POLAR is a compact Compton polarimeter consisting of 40$\times$ 40 plastic scintillator bars read out by 25 multi-anode PMTs. In May 2015, we performed a series of tests of the POLAR flight model with 100\% polarized x-rays bea…
▽ More
POLAR is space-borne detector designed for a precise measurement of gamma-ray polarization of the prompt emissions of Gamma-Ray Bursts in the energy range 50 keV - 500 keV. POLAR is a compact Compton polarimeter consisting of 40$\times$ 40 plastic scintillator bars read out by 25 multi-anode PMTs. In May 2015, we performed a series of tests of the POLAR flight model with 100\% polarized x-rays beams at the European Synchrotron Radiation Facility beam-line ID11 aming to study thresholds, crosstalk between channels and responses of POLAR flight model to polarized X-ray beams. In this paper we present the data analysis method and some analysis results. According the results, POLAR FM has good polarimetric capabilities.
△ Less
Submitted 24 April, 2017; v1 submitted 20 April, 2017;
originally announced April 2017.
-
Gain factor and parameter settings optimization of the new gamma-ray burst polarimeter POLAR
Authors:
X. F. Zhang,
W. Hajdas,
H. L. Xiao,
X. Wen,
B. B. Wu,
T. W. Bao,
T. Batsch,
T. Bernasconi,
F. Cadoux,
I. Cernuda,
J. Y. Chai,
Y. W. Dong,
N. Gauvin,
J. J. He,
M. Kole,
M. N. Kong,
C. Lechanoine-Leluc,
L. Li,
Z. H. Li,
J. T. Liu,
X. Liu,
R. Marcinkowski,
S. Orsi,
M. Pohl,
D. Rapin
, et al. (16 additional authors not shown)
Abstract:
As a space-borne detector POLAR is designed to conduct hard X-ray polarization measurements of gamma-ray bursts on the statistically significant sample of events and with an unprecedented accuracy. During its development phase a number of tests, calibrations runs and verification measurements were carried out in order to validate instrument functionality and optimize operational parameters. In thi…
▽ More
As a space-borne detector POLAR is designed to conduct hard X-ray polarization measurements of gamma-ray bursts on the statistically significant sample of events and with an unprecedented accuracy. During its development phase a number of tests, calibrations runs and verification measurements were carried out in order to validate instrument functionality and optimize operational parameters. In this article we present results on gain optimization togeter with verification data obtained in the course of broad laboratory and environmental tests. In particular we focus on exposures to the $^{137}$Cs radioactive source and determination of the gain dependence on the high voltage for all 1600 detection channels of the polarimeter. Performance of the instrument is described in detail with respect to the dynamic range, energy resolution and temperature dependence. Gain optimization algorithms and response non-uniformity studies are also broadly discussed. Results presented below constitute important parts for development of the POLAR calibration and operation database.
△ Less
Submitted 14 March, 2017; v1 submitted 12 March, 2017;
originally announced March 2017.
-
POLAR: Final Calibration and In-Flight Performance of a Dedicated GRB Polarimeter
Authors:
M. Kole,
T. W. Bao,
T. Batsch,
T. Bernasconi,
F. Cadoux,
J. Y. Chai,
Y. W. Dong,
N. Gauvin,
W. Hajdas,
J. J. He,
M. N. Kong,
S. W. Kong,
C. Lechanoine-Leluc,
L. Li,
Z. H. Li,
J. T. Liu,
X. Liu,
R. Marcinkowski,
S. Orsi,
M. Pohl,
N. Produit,
D. Rapin,
A. Rutczynska,
D. Rybka,
H. L. Shi
, et al. (19 additional authors not shown)
Abstract:
Gamma-ray polarimetry is a new powerful tool to study the processes responsible for the emission from astrophysical sources and the environments in which this emission takes place. Few successful polarimetric measurements have however been performed thus far in the gamma-ray energy band due to the difficulties involved. POLAR is a dedicated polarimeter designed to perform high precision measuremen…
▽ More
Gamma-ray polarimetry is a new powerful tool to study the processes responsible for the emission from astrophysical sources and the environments in which this emission takes place. Few successful polarimetric measurements have however been performed thus far in the gamma-ray energy band due to the difficulties involved. POLAR is a dedicated polarimeter designed to perform high precision measurements of the polarization of the emission from gamma-ray burst in the 50-500 keV energy range. This new polarimeter is expected to detect approximately 50 gamma-ray bursts per year while performing high precision polarization measurements on approximately 10 bursts per year. The instrument was launched into lower earth orbit as part of the second Chinese space lab, the Tiangong-2, on September 15th 2016 and has been taking data successfully since being switched on one week after. The instrument uses a segmented scintillator array consisting of 1600 plastic scintillator bars, read out by 25 flat-panel multi-anode photomultipliers, to measure the Compton scattering angles of incoming photons. The small segmentation and relatively large uniform effective area allow the instrument to measure the polarization of a large number of transient events, such as gamma-ray bursts, with an unprecedented precision during its two year life-time. The final flight model underwent detailed calibration prior to launch as well as intensive space qualification tests, a summary of which will be presented in this paper. The instrument design will be discussed first followed by an overview of the on-ground tests, finally the in-orbit behavior as measured during the first weeks of the mission will be presented.
△ Less
Submitted 13 December, 2016;
originally announced December 2016.
-
Constraining nova observables: direct measurements of resonance strengths in 33S(p,γ)34Cl
Authors:
J. Fallis,
A. Parikh,
P. F. Bertone,
S. Bishop,
L. Buchmann,
A. A. Chen,
G. Christian,
J. A. Clark,
J. M. D'Auria,
B. Davids,
C. M. Deibel,
B. R. Fulton,
U. Greife,
B. Guo,
U. Hager,
C. Herlitzius,
D. A. Hutcheon,
J. José,
A. M. Laird,
E. T. Li,
Z. H. Li,
G. Lian,
W. P. Liu,
L. Martin,
K. Nelson
, et al. (10 additional authors not shown)
Abstract:
The 33S(p,γ)34Cl reaction is important for constraining predictions of certain isotopic abundances in oxygen-neon novae. Models currently predict as much as 150 times the solar abundance of 33S in oxygen-neon nova ejecta. This overproduction factor may, however, vary by orders of magnitude due to uncertainties in the 33S(p,γ)34Cl reaction rate at nova peak temperatures. Depending on this rate, 33S…
▽ More
The 33S(p,γ)34Cl reaction is important for constraining predictions of certain isotopic abundances in oxygen-neon novae. Models currently predict as much as 150 times the solar abundance of 33S in oxygen-neon nova ejecta. This overproduction factor may, however, vary by orders of magnitude due to uncertainties in the 33S(p,γ)34Cl reaction rate at nova peak temperatures. Depending on this rate, 33S could potentially be used as a diagnostic tool for classifying certain types of presolar grains. Better knowledge of the 33S(p,γ)34Cl rate would also aid in interpreting nova observations over the S-Ca mass region and contribute to the firm establishment of the maximum endpoint of nova nucleosynthesis. Additionally, the total S elemental abundance which is affected by this reaction has been proposed as a thermometer to study the peak temperatures of novae. Previously, the 33S(p,γ)34Cl reaction rate had only been studied directly down to resonance energies of 432 keV. However, for nova peak temperatures of 0.2-0.4 GK there are 7 known states in 34Cl both below the 432 keV resonance and within the Gamow window that could play a dominant role. Direct measurements of the resonance strengths of these states were performed using the DRAGON recoil separator at TRIUMF. Additionally two new states within this energy region are reported. Several hydrodynamic simulations have been performed, using all available experimental information for the 33S(p,γ)34Cl rate, to explore the impact of the remaining uncertainty in this rate on nucleosynthesis in nova explosions. These calculations give a range of ~ 20-150 for the expected 33S overproduction factor, and a range of ~ 100-450 for the 32S/33S ratio expected in ONe novae.
△ Less
Submitted 13 September, 2013;
originally announced September 2013.
-
The electromagnetic calorimeter of the AMS-02 experiment
Authors:
M. Vecchi,
L. Basara,
G. Bigongiari,
F. Cervelli,
G. Chen,
G. M. Chen,
H. S. Chen,
G. Coignet,
S. Di Falco,
S. Elles,
A. Fiasson,
D. Fougeron,
G. Gallucci,
C. Goy,
M. Incagli,
R. Kossakowki,
V. Lepareur,
Z. H. Li,
M. Maire,
M. Paniccia,
F. Pilo,
S. Rosier-Lees,
X. W. Tang,
C. Vannini,
J. P. Vialle
, et al. (1 additional authors not shown)
Abstract:
The electromagnetic calorimeter (ECAL) of the AMS-02 experiment is a 3-dimensional sampling calorimeter, made of lead and scintillating fibers. The detector allows for a high granularity, with 18 samplings in the longitudinal direction, and 72 sampling in the lateral direction. The ECAL primary goal is to measure the energy of cosmic rays up to few TeV, however, thanks to the fine grained structur…
▽ More
The electromagnetic calorimeter (ECAL) of the AMS-02 experiment is a 3-dimensional sampling calorimeter, made of lead and scintillating fibers. The detector allows for a high granularity, with 18 samplings in the longitudinal direction, and 72 sampling in the lateral direction. The ECAL primary goal is to measure the energy of cosmic rays up to few TeV, however, thanks to the fine grained structure, it can also provide the separation of positrons from protons, in the GeV to TeV region. A direct measurement of high energy photons with accurate energy and direction determination can also be provided.
△ Less
Submitted 1 October, 2012;
originally announced October 2012.
-
New determination of the 13C(a, n)16O reaction rate and its influence on the s-process nucleosynthesis in AGB stars
Authors:
B. Guo,
Z. H. Li,
M. Lugaro,
J. Buntain,
D. Y. Pang,
Y. J. Li,
J. Su,
S. Q. Yan,
X. X. Bai,
Y. S. Chen,
Q. W. Fan,
S. J. Jin,
A. I. Karakas,
E. T. Li,
Z. C. Li,
G. Lian,
J. C. Liu,
X. Liu,
J. R. Shi,
N. C. Shu,
B. X. Wang,
Y. B. Wang,
S. Zeng,
W. P. Liu
Abstract:
We present a new measurement of the $α$-spectroscopic factor ($S_α$) and the asymptotic normalization coefficient (ANC) for the 6.356 MeV 1/2$^+$ subthreshold state of $^{17}$O through the $^{13}$C($^{11}$B, $^{7}$Li)$^{17}$O transfer reaction and we determine the $α$-width of this state. This is believed to have a strong effect on the rate of the $^{13}$C($α$, $n$)$^{16}$O reaction, the main neut…
▽ More
We present a new measurement of the $α$-spectroscopic factor ($S_α$) and the asymptotic normalization coefficient (ANC) for the 6.356 MeV 1/2$^+$ subthreshold state of $^{17}$O through the $^{13}$C($^{11}$B, $^{7}$Li)$^{17}$O transfer reaction and we determine the $α$-width of this state. This is believed to have a strong effect on the rate of the $^{13}$C($α$, $n$)$^{16}$O reaction, the main neutron source for {\it slow} neutron captures (the $s$-process) in asymptotic giant branch (AGB) stars. Based on the new width we derive the astrophysical S-factor and the stellar rate of the $^{13}$C($α$, $n$)$^{16}$O reaction. At a temperature of 100 MK our rate is roughly two times larger than that by \citet{cau88} and two times smaller than that recommended by the NACRE compilation. We use the new rate and different rates available in the literature as input in simulations of AGB stars to study their influence on the abundances of selected $s$-process elements and isotopic ratios. There are no changes in the final results using the different rates for the $^{13}$C($α$, $n$)$^{16}$O reaction when the $^{13}$C burns completely in radiative conditions. When the $^{13}$C burns in convective conditions, as in stars of initial mass lower than $\sim$2 $M_\sun$ and in post-AGB stars, some changes are to be expected, e.g., of up to 25% for Pb in our models. These variations will have to be carefully analyzed when more accurate stellar mixing models and more precise observational constraints are available.
△ Less
Submitted 3 August, 2012;
originally announced August 2012.