In-flight energy calibration of the space-borne Compton polarimeter POLAR
Authors:
Hualin Xiao,
Wojtek Hajdas,
Bobing Wu,
Nicolas Produit,
Jianchao Sun,
Merlin Kole,
Tianwei Bao,
Tancredi Bernasconi,
Tadeusz Batsch,
Franck Cadoux,
Junying Chai,
Yongwei Dong,
Ken Egli,
Neal Gauvin,
Minnan Kong,
Reinhold Kramert,
Siwei Kong,
Hancheng Li,
Lu Li,
Zhengheng Li,
Jiangtao Liu,
Xin Liu,
Radoslaw Marcinkowski,
Silvio Orsi,
Dominik K. Rybka
, et al. (17 additional authors not shown)
Abstract:
POLAR is a compact wide-field space-borne detector for precise measurements of the linear polarisation of hard X-rays emitted by transient sources in the energy range from 50 keV to 500 keV. It consists of a 40$\times$40 array of plastic scintillator bars used as a detection material. The bars are grouped in 25 detector modules. The energy range sensitivity of POLAR is optimized to match with the…
▽ More
POLAR is a compact wide-field space-borne detector for precise measurements of the linear polarisation of hard X-rays emitted by transient sources in the energy range from 50 keV to 500 keV. It consists of a 40$\times$40 array of plastic scintillator bars used as a detection material. The bars are grouped in 25 detector modules. The energy range sensitivity of POLAR is optimized to match with the prompt emission photons from the gamma-ray bursts (GRBs). Polarization measurements of the prompt emission would probe source geometries, emission mechanisms and magnetic structures in GRB jets. The instrument can also detect hard X-rays from solar flares and be used for precise measurement of their polarisation. POLAR was launched into a low Earth orbit on-board the Chinese space-lab TG-2 on September 15th, 2016. To achieve high accuracies in polarisation measurements it is essential to assure both before and during the flight a precise energy calibration. Such calibrations are performed with four low activity $^{22}$Na radioactive sources placed inside the instrument. Energy conversion factors are related to Compton edge positions from the collinear annihilation photons from the sources. This paper presents main principles of the in-flight calibration, describes studies of the method based on Monte Carlo simulations and its laboratory verification and finally provides some observation results based on the in-flight data analysis.
△ Less
Submitted 5 June, 2018; v1 submitted 24 October, 2017;
originally announced October 2017.
-
Design and construction of the POLAR detector
Authors:
N. Produit,
T. W. Bao,
T. Batsch,
T. Bernasconi,
I. Britvich,
F. Cadoux,
I. Cernuda,
J. Y. Chai,
Y. W. Dong,
N. Gauvin,
W. Hajdas,
M. Kole,
M. N. Kong,
R. Kramert,
L. Li,
J. T. Liu,
X. Liu,
R. Marcinkowski,
S. Orsi,
M. Pohl,
D. Rapin,
D. Rybka,
A. Rutczynska,
H. L. Shi,
P. Socha
, et al. (13 additional authors not shown)
Abstract:
The POLAR detector is a space based Gamma Ray Burst (GRB) polarimeter with a wide field of view, which covers almost half the sky. The instrument uses Compton scattering of gamma rays on a plastic scintillator hodoscope to measure the polarization of the incoming photons. The instrument has been successfully launched on board of the Chinese space laboratory Tiangong~2 on September 15, 2016. The co…
▽ More
The POLAR detector is a space based Gamma Ray Burst (GRB) polarimeter with a wide field of view, which covers almost half the sky. The instrument uses Compton scattering of gamma rays on a plastic scintillator hodoscope to measure the polarization of the incoming photons. The instrument has been successfully launched on board of the Chinese space laboratory Tiangong~2 on September 15, 2016. The construction of the instrument components is described in this article. Details are provided on problems encountered during the construction phase and their solutions. Initial performance of the instrument in orbit is as expected from ground tests and Monte Carlo simulation.
△ Less
Submitted 28 September, 2017; v1 submitted 21 September, 2017;
originally announced September 2017.
-
Calibration of the Space-borne Compton Polarimeter POLAR flight model with 100% polarized X-ray beams
Authors:
H. L. Xiao,
W. Hajdas,
P. Socha,
R. Marcinkowski,
B. B. Wu,
T. W. Bao,
J. Y. Chai,
Y. W. Dong,
M. N. Kong,
L. Li,
Z. H. Li,
J. T. Liu,
H. L. Shi,
L. M. Song,
J. C. Sun,
R. J. Wang,
Y. H. Wang,
X. Wen,
S. L. Xiong,
J. Zhang,
L. Y. Zhang,
S. N. Zhang,
X. F. Zhang,
Y. J. Zhang,
F. Cadoux
, et al. (10 additional authors not shown)
Abstract:
POLAR is space-borne detector designed for a precise measurement of gamma-ray polarization of the prompt emissions of Gamma-Ray Bursts in the energy range 50 keV - 500 keV. POLAR is a compact Compton polarimeter consisting of 40$\times$ 40 plastic scintillator bars read out by 25 multi-anode PMTs. In May 2015, we performed a series of tests of the POLAR flight model with 100\% polarized x-rays bea…
▽ More
POLAR is space-borne detector designed for a precise measurement of gamma-ray polarization of the prompt emissions of Gamma-Ray Bursts in the energy range 50 keV - 500 keV. POLAR is a compact Compton polarimeter consisting of 40$\times$ 40 plastic scintillator bars read out by 25 multi-anode PMTs. In May 2015, we performed a series of tests of the POLAR flight model with 100\% polarized x-rays beams at the European Synchrotron Radiation Facility beam-line ID11 aming to study thresholds, crosstalk between channels and responses of POLAR flight model to polarized X-ray beams. In this paper we present the data analysis method and some analysis results. According the results, POLAR FM has good polarimetric capabilities.
△ Less
Submitted 24 April, 2017; v1 submitted 20 April, 2017;
originally announced April 2017.