Mitigating Modal Noise in Multimode Circular Fibres by Optical Agitation using a Galvanometer
Authors:
Supriyo Ghosh,
Chantira Boonsri,
William Martin,
Hugh R. A. Jones,
Piyamas Choochalerm,
Sarah Usher,
Stephanos Yerolatsitis,
Thomas Wocial,
Thomas Wright
Abstract:
Modal noise appears due to the non-uniform and unstable distribution of light intensity among the finite number of modes in multimode fibres. It is an important limiting factor in measuring radial velocity precisely by fibre-fed high-resolution spectrographs. The problem can become particularly severe as the fibre's core become smaller and the number of modes that can propagate reduces. Thus, miti…
▽ More
Modal noise appears due to the non-uniform and unstable distribution of light intensity among the finite number of modes in multimode fibres. It is an important limiting factor in measuring radial velocity precisely by fibre-fed high-resolution spectrographs. The problem can become particularly severe as the fibre's core become smaller and the number of modes that can propagate reduces. Thus, mitigating modal noise in relatively small core fibres still remains a challenge. We present here a novel technique to suppress modal noise. Two movable mirrors in the form of a galvanometer reimage the mode-pattern of an input fibre to an output fibre. The mixing of modes coupled to the output fibre can be controlled by the movement of mirrors applying two sinusoidal signals through a voltage generator. We test the technique for four multimode circular fibres: 10 and 50 micron step-index, 50 micron graded-index, and a combination of 50 micron graded-index and 5:1 tapered fibres (GI50t). We present the results of mode suppression both in terms of the direct image of the output fibre and spectrum of white light obtained with the high-resolution spectrograph. We found that the galvanometer mitigated modal noise in all the tested fibres, but was most useful for smaller core fibres. However, there is a trade-off between the modal noise reduction and light-loss. The GI50t provides the best result with about 60% mitigation of modal noise at a cost of about 5% output light-loss. Our solution is easy to use and can be implemented in fibre-fed spectrographs.
△ Less
Submitted 28 December, 2023;
originally announced December 2023.
A Method to Achieve High Dynamic Range in a CMOS Image Sensor Using Interleaved Row Readout
Authors:
Thomas Wocial,
Konstantin D. Stefanov,
William E. Martin,
John R. Barnes,
Hugh R. A. Jones
Abstract:
We present a readout scheme for CMOS image sensors that can be used to achieve arbitrarily high dynamic range (HDR) in principle. The linear full well capacity (LFWC) in high signal regions was extended 50 times from 20 ke$^{-}$ to 984 ke$^{-}$ via an interlaced row-wise readout order, whilst the noise floor remained unchanged in low signal regions, resulting in a 34 dB increase in DR. The peak si…
▽ More
We present a readout scheme for CMOS image sensors that can be used to achieve arbitrarily high dynamic range (HDR) in principle. The linear full well capacity (LFWC) in high signal regions was extended 50 times from 20 ke$^{-}$ to 984 ke$^{-}$ via an interlaced row-wise readout order, whilst the noise floor remained unchanged in low signal regions, resulting in a 34 dB increase in DR. The peak signal-to-noise ratio (PSNR) is increased in a continuous fashion from 43 dB to 60 dB. This was achieved by summing user-selected rows which were read out multiple times. Centroiding uncertainties were lowered when template-fitting a projected pattern, compared to the standard readout scheme. Example applications are aimed at scientific imaging due to the linearity and PSNR increase.
△ Less
Submitted 10 October, 2022;
originally announced October 2022.