-
Operating in a deep underground facility improves the locking of gradiometric fluxonium qubits at the sweet spots
Authors:
Daria Gusenkova,
Francesco Valenti,
Martin Spiecker,
Simon Günzler,
Patrick Paluch,
Dennis Rieger,
Larisa-Milena Pioraş-Ţimbolmaş,
Liviu P. Zârbo,
Nicola Casali,
Ivan Colantoni,
Angelo Cruciani,
Stefano Pirro,
Laura Cardani,
Alexandru Petrescu,
Wolfgang Wernsdorfer,
Patrick Winkel,
Ioan M. Pop
Abstract:
We demonstrate flux-bias locking and operation of a gradiometric fluxonium artificial atom using two symmetric granular aluminum (grAl) loops to implement the superinductor. The gradiometric fluxonium shows two orders of magnitude suppression of sensitivity to homogeneous magnetic fields, which can be an asset for hybrid quantum systems requiring strong magnetic field biasing. By cooling down the…
▽ More
We demonstrate flux-bias locking and operation of a gradiometric fluxonium artificial atom using two symmetric granular aluminum (grAl) loops to implement the superinductor. The gradiometric fluxonium shows two orders of magnitude suppression of sensitivity to homogeneous magnetic fields, which can be an asset for hybrid quantum systems requiring strong magnetic field biasing. By cooling down the device in an external magnetic field while crossing the metal-to-superconductor transition, the gradiometric fluxonium can be locked either at $0$ or $Φ_0/2$ effective flux bias, corresponding to an even or odd number of trapped fluxons, respectively. At mK temperatures, the fluxon parity prepared during initialization survives to magnetic field bias exceeding $100 \,Φ_0$. However, even for states biased in the vicinity of $1 \,Φ_0$, we observe unexpectedly short fluxon lifetimes of a few hours, which cannot be explained by thermal or quantum phase slips. When operating in a deep-underground cryostat of the Gran Sasso laboratory, the fluxon lifetimes increase to days, indicating that ionizing events activate phase slips in the grAl superinductor.
△ Less
Submitted 24 January, 2022;
originally announced January 2022.
-
Non-linearity in the system of quasiparticles of a superconducting resonator
Authors:
M. Vignati,
C. Bellenghi,
L. Cardani,
N. Casali,
I. Colantoni,
A. Cruciani
Abstract:
We observed a strong non-linearity in the system of quasiparticles of a superconducting aluminum resonator, due to the Cooper-pair breaking from the absorbed readout power. We observed both negative and positive feedback effects, controlled by the detuning of the readout frequency, which are able to alter the relaxation time of quasiparticles by a factor greater than 10. We estimate that the (70+/…
▽ More
We observed a strong non-linearity in the system of quasiparticles of a superconducting aluminum resonator, due to the Cooper-pair breaking from the absorbed readout power. We observed both negative and positive feedback effects, controlled by the detuning of the readout frequency, which are able to alter the relaxation time of quasiparticles by a factor greater than 10. We estimate that the (70+/-5) % of the total non-linearity of the device is due to quasiparticles.
△ Less
Submitted 18 February, 2021;
originally announced February 2021.
-
Reducing the impact of radioactivity on quantum circuits in a deep-underground facility
Authors:
Laura Cardani,
Francesco Valenti,
Nicola Casali,
Gianluigi Catelani,
Thibault Charpentier,
Massimiliano Clemenza,
Ivan Colantoni,
Angelo Cruciani,
Luca Gironi,
Lukas Grünhaupt,
Daria Gusenkova,
Fabio Henriques,
Marc Lagoin,
Maria Martinez,
Giorgio Pettinari,
Claudia Rusconi,
Oliver Sander,
Alexey V. Ustinov,
Marc Weber,
Wolfgang Wernsdorfer,
Marco Vignati,
Stefano Pirro,
Ioan M. Pop
Abstract:
As quantum coherence times of superconducting circuits have increased from nanoseconds to hundreds of microseconds, they are currently one of the leading platforms for quantum information processing. However, coherence needs to further improve by orders of magnitude to reduce the prohibitive hardware overhead of current error correction schemes. Reaching this goal hinges on reducing the density of…
▽ More
As quantum coherence times of superconducting circuits have increased from nanoseconds to hundreds of microseconds, they are currently one of the leading platforms for quantum information processing. However, coherence needs to further improve by orders of magnitude to reduce the prohibitive hardware overhead of current error correction schemes. Reaching this goal hinges on reducing the density of broken Cooper pairs, so-called quasiparticles. Here, we show that environmental radioactivity is a significant source of nonequilibrium quasiparticles. Moreover, ionizing radiation introduces time-correlated quasiparticle bursts in resonators on the same chip, further complicating quantum error correction. Operating in a deep-underground lead-shielded cryostat decreases the quasiparticle burst rate by a factor fifty and reduces dissipation up to a factor four, showcasing the importance of radiation abatement in future solid-state quantum hardware.
△ Less
Submitted 5 May, 2020;
originally announced May 2020.
-
Measurements and simulations of athermal phonon transmission from silicon absorbers to aluminium sensors
Authors:
M. Martinez,
L. Cardani,
N. Casali,
A. Cruciani,
G. Pettinari,
M. Vignati
Abstract:
Phonon reflection and transmission at the interfaces plays a fundamental role in cryogenic particle detectors, in which the optimization of the phonon signal at the sensor (in case of phonon-mediated detectors) or the minimization of the heat transmission (when the detection occurs in the sensor itself) is of primary importance to improve sensitivity. Nevertheless, the mechanisms governing the pho…
▽ More
Phonon reflection and transmission at the interfaces plays a fundamental role in cryogenic particle detectors, in which the optimization of the phonon signal at the sensor (in case of phonon-mediated detectors) or the minimization of the heat transmission (when the detection occurs in the sensor itself) is of primary importance to improve sensitivity. Nevertheless, the mechanisms governing the phonon physics at the interfaces are still not completely understood. The two more successful models, the acoustic mismatch model (AMM) and diffuse mismatch model (DMM) are not able to explain all the accumulated experimental data and the measurement of the transmission coefficients between the materials remains a challenge. Here, we use measurements of the athermal phonon flux in aluminium Kinetic Inductance Detectors (KID) deposited on silicon substrates following a particle interaction to validate a Monte Carlo (MC) phonon simulation. We apply the Mattis-Bardeen theory to derive the phonon pulse energy and timing from the KID signal and compare the results with the MC for both AMM and DMM models, finding a remarkable good agreement for AMM, while diffuse reflection is clearly disfavored. For an aluminum film of 60 nm and a silicon substrate of 380~$μ$m, we obtain transmission coefficients Si-Al in the range [0.3-0.55] and Si-Teflon in the range [0.1-0.15].
△ Less
Submitted 13 June, 2019; v1 submitted 7 May, 2018;
originally announced May 2018.
-
Development of Lumped Element Kinetic Inductance Detectors for the W-Band
Authors:
A. Paiella,
A. Coppolecchia,
M. G. Castellano,
I. Colantoni,
A. Cruciani,
A. D'Addabbo,
P. de Bernardis,
S. Masi,
G. Presta
Abstract:
We are developing a Lumped Element Kinetic Inductance Detector (LEKID) array able to operate in the W-band (75-110 GHz) in order to perform ground-based Cosmic Microwave Background (CMB) and mm-wave astronomical observations. The W-band is close to optimal in terms of contamination of the CMB from Galactic synchrotron, free-free, and thermal interstellar dust. In this band, the atmosphere has very…
▽ More
We are developing a Lumped Element Kinetic Inductance Detector (LEKID) array able to operate in the W-band (75-110 GHz) in order to perform ground-based Cosmic Microwave Background (CMB) and mm-wave astronomical observations. The W-band is close to optimal in terms of contamination of the CMB from Galactic synchrotron, free-free, and thermal interstellar dust. In this band, the atmosphere has very good transparency, allowing interesting ground-based observations with large (>30 m) telescopes, achieving high angular resolution (<0.4 arcmin). In this work we describe the startup measurements devoted to the optimization of a W-band camera/spectrometer prototype for large aperture telescopes like the 64 m SRT (Sardinia Radio Telescope). In the process of selecting the best superconducting film for the LEKID, we characterized a 40 nm thick Aluminum 2-pixel array. We measured the minimum frequency able to break CPs (i.e. $hν=2Δ\left(T_{c}\right)=3.5k_{B}T_{c}$) obtaining $ν=95.5$ GHz, that corresponds to a critical temperature of 1.31 K. This is not suitable to cover the entire W-band. For an 80 nm layer the minimum frequency decreases to 93.2 GHz, which corresponds to a critical temperature of 1.28 K; this value is still suboptimal for W-band operation. Further increase of the Al film thickness results in bad performance of the detector. We have thus considered a Titanium-Aluminum bi-layer (10 nm thick Ti + 25 nm thick Al, already tested in other laboratories), for which we measured a critical temperature of 820 mK and a cut-on frequency of 65 GHz: so this solution allows operation in the entire W-band.
△ Less
Submitted 7 January, 2016;
originally announced January 2016.
-
High-speed phonon imaging using frequency-multiplexed kinetic inductance detectors
Authors:
L. J. Swenson,
A. Cruciani,
A. Benoit,
M. Roesch,
C. S. Yung,
A. Bideaud,
A. Monfardini
Abstract:
We present a measurement of phonon propagation in a silicon wafer utilizing an array of frequency-multiplexed superconducting resonators coupled to a single transmission line. The electronic readout permits fully synchronous array sampling with a per-resonator bandwidth of 1.2 MHz, allowing sub-$μ$s array imaging. This technological achievement is potentially vital in a variety of low-temperature…
▽ More
We present a measurement of phonon propagation in a silicon wafer utilizing an array of frequency-multiplexed superconducting resonators coupled to a single transmission line. The electronic readout permits fully synchronous array sampling with a per-resonator bandwidth of 1.2 MHz, allowing sub-$μ$s array imaging. This technological achievement is potentially vital in a variety of low-temperature applications, including single-photon counting, quantum-computing and dark-matter searches.
△ Less
Submitted 18 June, 2010; v1 submitted 28 April, 2010;
originally announced April 2010.