Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content

Showing 1–3 of 3 results for author: Stickland, D

Searching in archive hep-ex. Search in all archives.
.
  1. arXiv:1411.4413  [pdf, other

    hep-ex hep-ph

    Observation of the rare $B^0_s\toμ^+μ^-$ decay from the combined analysis of CMS and LHCb data

    Authors: The CMS, LHCb Collaborations, :, V. Khachatryan, A. M. Sirunyan, A. Tumasyan, W. Adam, T. Bergauer, M. Dragicevic, J. Erö, M. Friedl, R. Frühwirth, V. M. Ghete, C. Hartl, N. Hörmann, J. Hrubec, M. Jeitler, W. Kiesenhofer, V. Knünz, M. Krammer, I. Krätschmer, D. Liko, I. Mikulec, D. Rabady, B. Rahbaran , et al. (2807 additional authors not shown)

    Abstract: A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six sta… ▽ More

    Submitted 17 August, 2015; v1 submitted 17 November, 2014; originally announced November 2014.

    Comments: Correspondence should be addressed to cms-and-lhcb-publication-committees@cern.ch

    Report number: CERN-PH-EP-2014-220, CMS-BPH-13-007, LHCb-PAPER-2014-049

    Journal ref: Nature 522, 68-72 (04 June 2015)

  2. arXiv:1405.1926  [pdf

    physics.ins-det hep-ex

    Fast Beam Condition Monitor for CMS: performance and upgrade

    Authors: Jessica L. Leonard, Alan Bell, Piotr Burtowy, Anne Dabrowski, Maria Hempel, Hans Henschel, Wolfgang Lange, Wolfgang Lohmann, Nathaniel Odell, Marek Penno, Brian Pollack, Dominik Przyborowski, Vladimir Ryjov, David Stickland, Roberval Walsh, Weronika Warzycha, Agnieszka Zagozdzinska

    Abstract: The CMS beam and radiation monitoring subsystem BCM1F (Fast Beam Condition Monitor) consists of 8 individual diamond sensors situated around the beam pipe within the pixel detector volume, for the purpose of fast bunch-by-bunch monitoring of beam background and collision products. In addition, effort is ongoing to use BCM1F as an online luminosity monitor. BCM1F will be running whenever there is b… ▽ More

    Submitted 8 May, 2014; originally announced May 2014.

    Comments: 10 pages, 8 figures. To be published in NIM A as proceedings for the 9th Hiroshima Symposium on Semiconductor Tracking Detectors (2013)

    Report number: DESY 14-070

    Journal ref: Nuclear Inst. and Methods in Physics Research, A (2014), pp. 235-239

  3. arXiv:1110.0306  [pdf

    physics.ins-det hep-ex

    Measurement of the CMS Magnetic Field

    Authors: V. I. Klyukhin, A. Ball, F. Bergsma, D. Campi, B. Curé, A. Gaddi, H. Gerwig, A. Hervé, J. Korienek, F. Linde, C. Lindenmeyer, R. Loveless, M. Mulders, T. Nebel, R. P. Smith, D. Stickland, G. Teafoe, L. Veillet, J. K. Zimmerman

    Abstract: The measurement of the magnetic field in the tracking volume inside the superconducting coil of the Compact Muon Solenoid (CMS) detector under construction at CERN is done with a fieldmapper designed and produced at Fermilab. The fieldmapper uses 10 3-D B-sensors (Hall probes) developed at NIKHEF and calibrated at CERN to precision 0.05% for a nominal 4 T field. The precise fieldmapper measurement… ▽ More

    Submitted 3 October, 2011; originally announced October 2011.

    Comments: 4 pages, 5 figures, 15 references

    Journal ref: IEEE Trans on Appl. Superconduct., vol. 18, no. 2, pp. 295-298, June 2008