The CeBrA demonstrator for particle-$γ$ coincidence experiments at the FSU Super-Enge Split-Pole Spectrograph
Authors:
A. L. Conley,
B. Kelly,
M. Spieker,
R. Aggarwal,
S. Ajayi,
L. T. Baby,
S. Baker,
C. Benetti,
I. Conroy,
P. D. Cottle,
I. B. D`Amato,
P. DeRosa,
J. Esparza,
S. Genty,
K. Hanselman,
I. Hay,
M. Heinze,
D. Houlihan,
M. I. Khawaja,
P. S. Kielb,
A. N. Kuchera,
G. W. McCann,
A. B. Morelock,
E. Lopez-Saavedra,
R. Renom
, et al. (8 additional authors not shown)
Abstract:
We report on a highly selective experimental setup for particle-$γ$ coincidence experiments at the Super-Enge Split-Pole Spectrograph (SE-SPS) of the John D. Fox Superconducting Linear Accelerator Laboratory at Florida State University (FSU) using fast CeBr$_3$ scintillators for $γ$-ray detection. Specifically, we report on the results of characterization tests for the first five CeBr$_3$ scintill…
▽ More
We report on a highly selective experimental setup for particle-$γ$ coincidence experiments at the Super-Enge Split-Pole Spectrograph (SE-SPS) of the John D. Fox Superconducting Linear Accelerator Laboratory at Florida State University (FSU) using fast CeBr$_3$ scintillators for $γ$-ray detection. Specifically, we report on the results of characterization tests for the first five CeBr$_3$ scintillation detectors of the CeBr$_3$ Array (CeBrA) with respect to energy resolution and timing characteristics. We also present results from the first particle-$γ$ coincidence experiments successfully performed with the CeBrA demonstrator and the FSU SE-SPS. We show that with the new setup, $γ$-decay branching ratios and particle-$γ$ angular correlations can be measured very selectively using narrow excitation energy gates, which are possible thanks to the excellent particle energy resolution of the SE-SPS. In addition, we highlight that nuclear level lifetimes in the nanoseconds regime can be determined by measuring the time difference between particle detection with the SE-SPS focal-plane scintillator and $γ$-ray detection with the fast CeBrA detectors. Selective excitation energy gates with the SE-SPS exclude any feeding contributions to these lifetimes.
△ Less
Submitted 1 November, 2023;
originally announced November 2023.
CLARION2-TRINITY: a Compton-suppressed HPGe and GAGG:Ce-Si-Si array for absolute cross-section measurements with heavy ions
Authors:
T. J. Gray,
J. M. Allmond,
D. T. Dowling,
M. Febbraro,
T. T. King,
S. D. Pain,
D. W. Stracener,
S. Ajayi,
J. Aragon,
L. Baby,
P. Barber,
C. Benetti,
S. Bhattacharya,
R. Boisseau,
J. Gibbons,
S. L. Tabor,
V. Tripathi,
C. Wibisono,
I. Wiedenhoever,
L. Bignell,
M. S. M. Gerathy,
G. Lane,
L. J. McKie,
A. J. Mitchell,
J. Pope
, et al. (4 additional authors not shown)
Abstract:
The design and performance of a new Compton-suppressed HPGe and charged-particle array, CLARION2-TRINITY, are described. The TRINITY charged-particle array is comprised of 64 Cerium-doped Gadolinium Aluminium Gallium Garnet (GAGG:Ce) crystals configured into five rings spanning 7-54 degrees, and two annular silicon detectors that can shadow or extend the angular coverage to backward angles with mi…
▽ More
The design and performance of a new Compton-suppressed HPGe and charged-particle array, CLARION2-TRINITY, are described. The TRINITY charged-particle array is comprised of 64 Cerium-doped Gadolinium Aluminium Gallium Garnet (GAGG:Ce) crystals configured into five rings spanning 7-54 degrees, and two annular silicon detectors that can shadow or extend the angular coverage to backward angles with minimal $γ$-ray attenuation. GAGG:Ce is a non-hygroscopic, bright, and relatively fast scintillator with a light distribution well matched to SiPMs. Count rates up to 40 kHz per crystal are sustainable. Fundamental characteristics of GAGG:Ce are measured and presented, including light- and heavy-ion particle identification (PID) capability, pulse-height defects, radiation hardness, and emission spectra. The CLARION2 array consists of up to 16 Compton-suppressed HPGe Clover detectors ($\approx4\%$ efficiency at 1 MeV) configured into four rings (eight HPGe crystal rings) using a non-Archimedean geometry that suppresses back-to-back coincident 511-keV gamma rays. The entire array is instrumented with 100- and 500-MHz (14 bit) waveform digitizers which enable triggerless operation, pulse-shape discrimination, fast timing, and pileup correction. Finally, two examples of experimental data taken during the commissioning of the CLARION2-TRINITY system are given: a PID spectrum from $^{16}$O + $^{18}$O fusion-evaporation, and PID and Doppler-corrected $γ$-ray spectra from $^{48}$Ti + $^{12}$C Coulomb excitation.
△ Less
Submitted 10 August, 2022;
originally announced August 2022.