-
CLARION2-TRINITY: a Compton-suppressed HPGe and GAGG:Ce-Si-Si array for absolute cross-section measurements with heavy ions
Authors:
T. J. Gray,
J. M. Allmond,
D. T. Dowling,
M. Febbraro,
T. T. King,
S. D. Pain,
D. W. Stracener,
S. Ajayi,
J. Aragon,
L. Baby,
P. Barber,
C. Benetti,
S. Bhattacharya,
R. Boisseau,
J. Gibbons,
S. L. Tabor,
V. Tripathi,
C. Wibisono,
I. Wiedenhoever,
L. Bignell,
M. S. M. Gerathy,
G. Lane,
L. J. McKie,
A. J. Mitchell,
J. Pope
, et al. (4 additional authors not shown)
Abstract:
The design and performance of a new Compton-suppressed HPGe and charged-particle array, CLARION2-TRINITY, are described. The TRINITY charged-particle array is comprised of 64 Cerium-doped Gadolinium Aluminium Gallium Garnet (GAGG:Ce) crystals configured into five rings spanning 7-54 degrees, and two annular silicon detectors that can shadow or extend the angular coverage to backward angles with mi…
▽ More
The design and performance of a new Compton-suppressed HPGe and charged-particle array, CLARION2-TRINITY, are described. The TRINITY charged-particle array is comprised of 64 Cerium-doped Gadolinium Aluminium Gallium Garnet (GAGG:Ce) crystals configured into five rings spanning 7-54 degrees, and two annular silicon detectors that can shadow or extend the angular coverage to backward angles with minimal $γ$-ray attenuation. GAGG:Ce is a non-hygroscopic, bright, and relatively fast scintillator with a light distribution well matched to SiPMs. Count rates up to 40 kHz per crystal are sustainable. Fundamental characteristics of GAGG:Ce are measured and presented, including light- and heavy-ion particle identification (PID) capability, pulse-height defects, radiation hardness, and emission spectra. The CLARION2 array consists of up to 16 Compton-suppressed HPGe Clover detectors ($\approx4\%$ efficiency at 1 MeV) configured into four rings (eight HPGe crystal rings) using a non-Archimedean geometry that suppresses back-to-back coincident 511-keV gamma rays. The entire array is instrumented with 100- and 500-MHz (14 bit) waveform digitizers which enable triggerless operation, pulse-shape discrimination, fast timing, and pileup correction. Finally, two examples of experimental data taken during the commissioning of the CLARION2-TRINITY system are given: a PID spectrum from $^{16}$O + $^{18}$O fusion-evaporation, and PID and Doppler-corrected $γ$-ray spectra from $^{48}$Ti + $^{12}$C Coulomb excitation.
△ Less
Submitted 10 August, 2022;
originally announced August 2022.
-
Detection of an Unidentified Soft X-ray Emission Feature in NGC 5548
Authors:
Liyi Gu,
Junjie Mao,
Jelle S. Kaastra,
Missagh Mehdipour,
Ciro Pinto,
Sam Grafton-Waters,
Stefano Bianchi,
Hermine Landt,
Graziella Branduardi-Raymont,
Elisa Costantini,
Jacobo Ebrero,
Pierre-Olivier Petrucci,
Ehud Behar,
Laura di Gesu,
Barbara De Marco,
Giorgio Matt,
Jake A. J. Mitchell,
Uria Peretz,
Francesco Ursini,
Martin Ward
Abstract:
NGC~5548 is an X-ray bright Seyfert 1 active galaxy. It exhibits a variety of spectroscopic features in the soft X-ray band, including in particular the absorption by the AGN outflows of a broad range of ionization states, with column densities up to 1E27 /m^2, and having speeds up to several thousand kilometers per second. The known emission features are in broad agreement with photoionized X-ray…
▽ More
NGC~5548 is an X-ray bright Seyfert 1 active galaxy. It exhibits a variety of spectroscopic features in the soft X-ray band, including in particular the absorption by the AGN outflows of a broad range of ionization states, with column densities up to 1E27 /m^2, and having speeds up to several thousand kilometers per second. The known emission features are in broad agreement with photoionized X-ray narrow and broad emission line models. We report on an X-ray spectroscopic study using 1.1 Ms XMM-Newton and 0.9 Ms Chandra grating observations of NGC 5548 spanning two decades. The aim is to search and characterize any potential spectroscopic features in addition to the known primary spectral components that are already modeled in high precision. We detect a weak unidentified excess emission feature at 18.4 Angstrom (18.1 Angstrom in the restframe). The feature is seen at >5 sigma statistical significance taking into account the look elsewhere effect. No known instrumental issues, atomic transitions, and astrophysical effects can explain this excess. The observed intensity of the possible feature seems to anti-correlate in time with the hardness ratio of the source. However, the variability might not be intrinsic, it might be caused by the time-variable obscuration by the outflows. An intriguing possibility is the line emission from charge exchange between a partially ionized outflow and a neutral layer in the same outflow, or in the close environment. Other possibilities, such as emission from a highly-ionized component with high outflowing speed, cannot be fully ruled out.
△ Less
Submitted 19 July, 2022;
originally announced July 2022.
-
Pulse Shape Discrimination of low-energy nuclear and electron recoils for improved particle identification in NaI:Tl
Authors:
N. J. Spinks,
L. J. Bignell,
G. J. Lane,
A. Akber,
E. Barberio,
T. Baroncelli,
B. J. Coombes,
J. T. H. Dowie,
T. K. Eriksen,
M. S. M. Gerathy,
T. J. Gray,
I. Mahmood,
B. P. McCormick,
W. J. D. Melbourne,
A. J. Mitchell,
F. Nuti,
M. S. Rahman,
F. Scutti,
A. E. Stuchbery,
H. Timmers,
P. Urquijo,
Y. Y. Zhong,
M. J. Zurowski
Abstract:
The scintillation mechanism in NaI:Tl crystals produces different pulse shapes that are dependent on the incoming particle type. The time distribution of scintillation light from nuclear recoil events decays faster than for electron recoil events and this difference can be categorised using various Pulse Shape Discrimination (PSD) techniques. In this study, we measured nuclear and electron recoils…
▽ More
The scintillation mechanism in NaI:Tl crystals produces different pulse shapes that are dependent on the incoming particle type. The time distribution of scintillation light from nuclear recoil events decays faster than for electron recoil events and this difference can be categorised using various Pulse Shape Discrimination (PSD) techniques. In this study, we measured nuclear and electron recoils in a NaI:Tl crystal, with electron equivalent energies between 2 and 40 keV. We report on a new PSD approach, based on an event-type likelihood; this outperforms the charge-weighted mean-time, which is the conventional metric for PSD in NaI:Tl. Furthermore, we show that a linear combination of the two methods improves the discrimination power at these energies.
△ Less
Submitted 18 May, 2022;
originally announced May 2022.
-
Quenching factor measurements of sodium nuclear recoils in NaI:Tl determined by spectrum fitting
Authors:
L. J. Bignell,
I. Mahmood,
F. Nuti,
G. J. Lane,
A. Akber,
E. Barberio,
T. Baroncelli,
B. Coombes,
W. Dix,
J. T. H. Dowie,
T. Eriksen,
M. S. M. Gerathy,
T. J. Gray,
B. P. McCormick,
A. J. Mitchell,
M. S. Rahman,
F. Scutti,
N. J. Spinks,
A. E. Stuchbery,
H. Timmers,
P. Urquijo,
L. Wang,
Y. Y. Zhong,
M. Zurowski
Abstract:
We have performed measurements of sodium nuclear recoils in NaI:Tl crystals, following scattering by neutrons produced in a $^{7}$Li(p,n)$^{7}$Be reaction. Understanding the light output from such recoils, which is reduced relative to electrons of equivalent energy by the quenching factor, is critical to interpret dark matter experiments that search for nuclear scattering interactions. We have dev…
▽ More
We have performed measurements of sodium nuclear recoils in NaI:Tl crystals, following scattering by neutrons produced in a $^{7}$Li(p,n)$^{7}$Be reaction. Understanding the light output from such recoils, which is reduced relative to electrons of equivalent energy by the quenching factor, is critical to interpret dark matter experiments that search for nuclear scattering interactions. We have developed a spectrum-fitting methodology to extract the quenching factor from our measurements, and report quenching factors for nuclear recoil energies between 36 and 401 keV. Our results agree with other recent quenching factor measurements that use quasi-monoenergetic neutron sources. The new method will be applied in the future to the NaI:Tl crystals used in the SABRE experiment.
△ Less
Submitted 15 April, 2021; v1 submitted 4 February, 2021;
originally announced February 2021.
-
The X-Array and SATURN: A new decay-spectroscopy station for CARIBU
Authors:
A. J. Mitchell,
P. F. Bertone,
B. DiGiovine,
C. J. Lister,
M. P. Carpenter,
P. Chowdhury,
J. A. Clark,
N. D'Olympia,
A. Y. Deo,
F. G. Kondev,
E. A. McCutchan,
J. Rohrer,
G. Savard,
D. Seweryniak,
S. Zhu
Abstract:
A new decay-spectroscopy station has been commissioned for experiments with low-energy, fission-fragment radioactive beams from the CARIBU ion source. The new set-up consists of the 'X-array', a highly-efficient array of HPGe clover detectors, and 'SATURN' (Scintillator And Tape Using Radioactive Nuclei), a plastic scintillator detector combined with a tape-transport system for detection of beta p…
▽ More
A new decay-spectroscopy station has been commissioned for experiments with low-energy, fission-fragment radioactive beams from the CARIBU ion source. The new set-up consists of the 'X-array', a highly-efficient array of HPGe clover detectors, and 'SATURN' (Scintillator And Tape Using Radioactive Nuclei), a plastic scintillator detector combined with a tape-transport system for detection of beta particles and removal of long-lived isobaric decay products.
△ Less
Submitted 19 December, 2015;
originally announced December 2015.