-
The Frascati Beam Test Facility
Authors:
B. Buonomo,
F. Cardelli,
C. Di Giulio,
D. Di Giovenale,
L. G. Foggetta,
C. Taruggi
Abstract:
From 2004 the Frascati Beam Test Facility (BTF) in the DAFNE accelerator complex provides to the external user up to 1E10 electrons per bunch or up to 10E9 positrons per bunch to develop their detectors. After an upgrade program terminated in 2020 of the beam test facility a description of the status and available beam lines will be done.
From 2004 the Frascati Beam Test Facility (BTF) in the DAFNE accelerator complex provides to the external user up to 1E10 electrons per bunch or up to 10E9 positrons per bunch to develop their detectors. After an upgrade program terminated in 2020 of the beam test facility a description of the status and available beam lines will be done.
△ Less
Submitted 31 August, 2023; v1 submitted 6 August, 2023;
originally announced August 2023.
-
Performance of scintillating tiles with direct silicon-photomultiplier (SiPM) readout for application to large area detectors
Authors:
A. Balla,
B. Buonomo,
V. Cafaro,
A. Calcaterra,
F. Cardelli,
P. Ciambrone,
V. Cicero,
D. Di Giovenale,
C. Di Giulio,
G. Felici,
L. G. Foggetta,
V. Giordano,
G. Lanfranchi,
I. Lax,
A. Montanari,
G. Papalino,
A. Paoloni,
T. Rovelli,
A. Saputi,
G. Torromeo,
N. Tosi
Abstract:
The light yield, the time resolution and the efficiency of different types of scintillating tiles with direct Silicon Photomultiplier readout and instrumented with a customised front-end electronics have been measured at the Beam Test Facility of Laboratori Nazionali di Frascati and several test stands. The results obtained with different configurations are presented. A time resolution of the orde…
▽ More
The light yield, the time resolution and the efficiency of different types of scintillating tiles with direct Silicon Photomultiplier readout and instrumented with a customised front-end electronics have been measured at the Beam Test Facility of Laboratori Nazionali di Frascati and several test stands. The results obtained with different configurations are presented. A time resolution of the order of 300 ps, a light yield of more than 230 photo-electrons, and an efficiency better than 99.8 $\%$ are obtained with $\sim 225$ cm$^2$ large area tiles. This technology is suitable for a wide range of applications in high-energy physics, in particular for large area muon and timing detectors.
△ Less
Submitted 17 September, 2021;
originally announced September 2021.
-
Energy spread minimization in a beam-driven plasma wakefield accelerator
Authors:
R. Pompili,
M. P. Anania,
M. Behtouei,
M. Bellaveglia,
A. Biagioni,
F. G. Bisesto,
M. Cesarini,
E. Chiadroni,
A. Cianchi,
G. Costa,
M. Croia,
A. Del Dotto,
D. Di Giovenale,
M. Diomede,
F. Dipace,
M. Ferrario,
A. Giribono,
V. Lollo,
L. Magnisi,
M. Marongiu,
A. Mostacci,
G. Di Pirro,
S. Romeo,
A. R. Rossi,
J. Scifo
, et al. (4 additional authors not shown)
Abstract:
Next-generation plasma-based accelerators can push electron bunches to gigaelectronvolt energies within centimetre distances. The plasma, excited by a driver pulse, generates large electric fields that can efficiently accelerate a trailing witness bunch making possible the realization of laboratory-scale applications ranging from high-energy colliders to ultra-bright light sources. So far several…
▽ More
Next-generation plasma-based accelerators can push electron bunches to gigaelectronvolt energies within centimetre distances. The plasma, excited by a driver pulse, generates large electric fields that can efficiently accelerate a trailing witness bunch making possible the realization of laboratory-scale applications ranging from high-energy colliders to ultra-bright light sources. So far several experiments have demonstrated a significant acceleration but the resulting beam quality, especially the energy spread, is still far from state of the art conventional accelerators. Here we show the results of a beam-driven plasma acceleration experiment where we used an electron bunch as a driver followed by an ultra-short witness. The experiment demonstrates, for the first time, an innovative method to achieve an ultra-low energy spread of the accelerated witness of about 0.1%. This is an order of magnitude smaller than what has been obtained so far. The result can lead to a major breakthrough toward the optimization of the plasma acceleration process and its implementation in forthcoming compact machines for user-oriented applications.
△ Less
Submitted 2 June, 2020;
originally announced June 2020.
-
The FLAME laser at SPARC_LAB
Authors:
F. G. Bisesto,
M. P. Anania,
M. Bellaveglia,
E. Chiadroni,
A. Cianchi,
G. Costa,
A. Curcio,
D. Di Giovenale,
G. Di Pirro,
M. Ferrario,
F. Filippi,
A. Gallo,
A. Marocchino,
R. Pompili,
A. Zigler,
C. Vaccarezza
Abstract:
FLAME is a high power laser system installed at the SPARC_LAB Test Facility in Frascati (Italy). The ultra-intense laser pulses are employed to study the interaction with matter for many purposes: electron acceleration through LWFA, ion and proton generation exploiting the TNSA mechanism, study of new radiation sources and development of new electron diagnostics. In this work, an overview of the F…
▽ More
FLAME is a high power laser system installed at the SPARC_LAB Test Facility in Frascati (Italy). The ultra-intense laser pulses are employed to study the interaction with matter for many purposes: electron acceleration through LWFA, ion and proton generation exploiting the TNSA mechanism, study of new radiation sources and development of new electron diagnostics. In this work, an overview of the FLAME laser system will be given, together with recent experimental results
△ Less
Submitted 1 February, 2018;
originally announced February 2018.
-
Overview of Plasma Lens Experiments and Recent Results at SPARC_LAB
Authors:
E. Chiadroni,
M. P. Anania,
M. Bellaveglia,
A. Biagioni,
F. Bisesto,
E. Brentegani,
F. Cardelli,
A. Cianchi,
G. Costa,
D. Di Giovenale,
G. Di Pirro,
M. Ferrario,
F. Filippi,
A. Gallo,
A. Giribono,
A. Marocchino,
A. Mostacci,
L. Piersanti,
R. Pompili,
J. B. Rosenzweig,
A. R. Rossi,
J. Scifo,
V. Shpakov,
C. Vaccarezza,
F. Villa
, et al. (1 additional authors not shown)
Abstract:
Beam injection and extraction from a plasma module is still one of the crucial aspects to solve in order to produce high quality electron beams with a plasma accelerator. Proper matching conditions require to focus the incoming high brightness beam down to few microns size and to capture a high divergent beam at the exit without loss of beam quality. Plasma-based lenses have proven to provide focu…
▽ More
Beam injection and extraction from a plasma module is still one of the crucial aspects to solve in order to produce high quality electron beams with a plasma accelerator. Proper matching conditions require to focus the incoming high brightness beam down to few microns size and to capture a high divergent beam at the exit without loss of beam quality. Plasma-based lenses have proven to provide focusing gradients of the order of kT/m with radially symmetric focusing thus promising compact and affordable alternative to permanent magnets in the design of transport lines. In this paper an overview of recent experiments and future perspectives of plasma lenses is reported.
△ Less
Submitted 1 February, 2018;
originally announced February 2018.
-
EuPRAXIA@SPARC_LAB Design study towards a compact FEL facility at LNF
Authors:
M. Ferrario,
D. Alesini,
M. P. Anania,
M. Artioli,
A. Bacci,
S. Bartocci,
R. Bedogni,
M. Bellaveglia,
A. Biagioni,
F. Bisesto,
F. Brandi,
E. Brentegani,
F. Broggi,
B. Buonomo,
P. L. Campana,
G. Campogiani,
C. Cannaos,
S. Cantarella,
F. Cardelli,
M. Carpanese,
M. Castellano,
G. Castorina,
N. Catalan Lasheras,
E. Chiadroni,
A. Cianchi
, et al. (95 additional authors not shown)
Abstract:
On the wake of the results obtained so far at the SPARC\_LAB test-facility at the Laboratori Nazionali di Frascati (Italy), we are currently investigating the possibility to design and build a new multi-disciplinary user-facility, equipped with a soft X-ray Free Electron Laser (FEL) driven by a $\sim$1 GeV high brightness linac based on plasma accelerator modules. This design study is performed in…
▽ More
On the wake of the results obtained so far at the SPARC\_LAB test-facility at the Laboratori Nazionali di Frascati (Italy), we are currently investigating the possibility to design and build a new multi-disciplinary user-facility, equipped with a soft X-ray Free Electron Laser (FEL) driven by a $\sim$1 GeV high brightness linac based on plasma accelerator modules. This design study is performed in synergy with the EuPRAXIA design study. In this paper we report about the recent progresses in the on going design study of the new facility.
△ Less
Submitted 26 January, 2018;
originally announced January 2018.
-
Recent results at SPARC_LAB
Authors:
R. Pompili,
M. P. Anania,
M. Bellaveglia,
A. Biagioni,
S. Bini,
F. Bisesto,
E. Chiadroni,
A. Cianchi,
G. Costa,
D. Di Giovenale,
M. Ferrario,
F. Filippi,
A. Gallo,
A. Giribono,
V. Lollo,
A. Marocchino,
V. Martinelli,
A. Mostacci,
G. Di Pirro,
S. Romeo,
J. Scifo,
V. Shpakov,
C. Vaccarezza,
F. Villa,
A. Zigler
Abstract:
The current activity of the SPARC_LAB test-facility is focused on the realization of plasma-based acceleration experiments with the aim to provide accelerating field of the order of several GV/m while maintaining the overall quality (in terms of energy spread and emittance) of the accelerated electron bunch. In the following, the current status of such an activity is presented. We also show result…
▽ More
The current activity of the SPARC_LAB test-facility is focused on the realization of plasma-based acceleration experiments with the aim to provide accelerating field of the order of several GV/m while maintaining the overall quality (in terms of energy spread and emittance) of the accelerated electron bunch. In the following, the current status of such an activity is presented. We also show results related to the usability of plasmas as focusing lenses in view of a complete plasma-based focusing and accelerating system.
△ Less
Submitted 18 January, 2018;
originally announced January 2018.
-
Wake fields effects in dielectric capillary
Authors:
A. Biagioni,
M. P. Anania,
M. Bellaveglia,
E. Brentegani,
G. Castorina,
E. Chiadroni,
A. Cianchi,
D. Di Giovenale,
G. Di Pirro,
H. Fares,
L. Ficcadenti,
F. Filippi,
M. Ferrario,
A. Mostacci,
R. Pompili,
J. Scifo,
B. Spataro,
C. Vaccarezza,
F. Villa,
A. Zigler
Abstract:
Plasma wake-field acceleration experiments are performed at the SPARC LAB test facility by using a gas-filled capillary plasma source composed of a dielectric capillary. The electron can reach GeV energy in a few centimeters, with an accelerating gradient orders of magnitude larger than provided by conventional techniques. In this acceleration scheme, wake fields produced by passing electron beams…
▽ More
Plasma wake-field acceleration experiments are performed at the SPARC LAB test facility by using a gas-filled capillary plasma source composed of a dielectric capillary. The electron can reach GeV energy in a few centimeters, with an accelerating gradient orders of magnitude larger than provided by conventional techniques. In this acceleration scheme, wake fields produced by passing electron beams through dielectric structures can determine a strong beam instability that represents an important hurdle towards the capability to focus high-current electron beams in the transverse plane. For these reasons, the estimation of the transverse wakefield amplitudes assumes a fundamental role in the implementation of the plasma wake-field acceleration. In this work, it presented a study to investigate which parameters affect the wake-field formation inside a cylindrical dielectric structure, both the capillary dimensions and the beam parameters, and it is introduced a quantitative evaluation of the longitudinal and transverse electric fields.
△ Less
Submitted 12 January, 2018;
originally announced January 2018.
-
Nano-machining, surface analysis and emittance measurements of a copper photocathode at SPARC_LAB
Authors:
J. Scifo,
D. Alesini,
M. P. Anania,
M. Bellaveglia,
S. Bellucci,
A. Biagioni,
F. Bisesto,
F. Cardelli,
E. Chiadroni,
A. Cianchi,
G. Costa,
D. Di Giovenale,
G. Di Pirro,
R. Di Raddo,
D. H. Dowell,
M. Ferrario,
A. Giribono,
A. Lorusso,
F. Micciulla,
A. Mostacci,
D. Passeri,
A. Perrone,
L. Piersanti,
R. Pompili,
V. Shpakov
, et al. (3 additional authors not shown)
Abstract:
R\&D activity on Cu photocathodes is under development at the SPARC\_LAB test facility to fully characterize each stage of the photocathode "life" and to have a complete overview of the photoemission properties in high brightness photo-injectors. The nano(n)-machining process presented here consists in diamond milling, and blowing with dry nitrogen. This procedure reduces the roughness of the cath…
▽ More
R\&D activity on Cu photocathodes is under development at the SPARC\_LAB test facility to fully characterize each stage of the photocathode "life" and to have a complete overview of the photoemission properties in high brightness photo-injectors. The nano(n)-machining process presented here consists in diamond milling, and blowing with dry nitrogen. This procedure reduces the roughness of the cathode surface and prevents surface contamination introduced by other techniques, such as polishing with diamond paste or the machining with oil. Both high roughness and surface contamination cause an increase of intrinsic emittance and consequently a reduction of the overall electron beam brightness. To quantify these effects, we have characterized the photocathode surface in terms of roughness measurement, and morphology and chemical composition analysis by means of Scanning Electron Microscopy (SEM), Energy Dispersive Spectroscopy (EDS), and Atomic Force Microscopy (AFM) techniques. The effects of n-machining on the electron beam quality have been also investigated through emittance measurements before and after the surface processing technique. Finally, we present preliminary emittance studies of yttrium thin film on Cu photocathodes.
△ Less
Submitted 11 January, 2018;
originally announced January 2018.
-
IRIDE White Book, An Interdisciplinary Research Infrastructure based on Dual Electron linacs&lasers
Authors:
D. Alesini,
M. Alessandroni,
M. P. Anania,
S. Andreas,
M. Angelone,
A. Arcovito,
F. Arnesano,
M. Artioli,
L. Avaldi,
D. Babusci,
A. Bacci,
A. Balerna,
S. Bartalucci,
R. Bedogni,
M. Bellaveglia,
F. Bencivenga,
M. Benfatto,
S. Biedron,
V. Bocci,
M. Bolognesi,
P. Bolognesi,
R. Boni,
R. Bonifacio,
M. Boscolo,
F. Boscherini
, et al. (189 additional authors not shown)
Abstract:
This report describes the scientific aims and potentials as well as the preliminary technical design of IRIDE, an innovative tool for multi-disciplinary investigations in a wide field of scientific, technological and industrial applications. IRIDE will be a high intensity 'particle factory', based on a combination of a high duty cycle radio-frequency superconducting electron linac and of high ener…
▽ More
This report describes the scientific aims and potentials as well as the preliminary technical design of IRIDE, an innovative tool for multi-disciplinary investigations in a wide field of scientific, technological and industrial applications. IRIDE will be a high intensity 'particle factory', based on a combination of a high duty cycle radio-frequency superconducting electron linac and of high energy lasers. Conceived to provide unique research possibilities for particle physics, for condensed matter physics, chemistry and material science, for structural biology and industrial applications, IRIDE will open completely new research possibilities and advance our knowledge in many branches of science and technology. IRIDE will contribute to open new avenues of discoveries and to address most important riddles: What does matter consist of? What is the structure of proteins that have a fundamental role in life processes? What can we learn from protein structure to improve the treatment of diseases and to design more efficient drugs? But also how does an electronic chip behave under the effect of radiations? How can the heat flow in a large heat exchanger be optimized? The scientific potential of IRIDE is far reaching and justifies the construction of such a large facility in Italy in synergy with the national research institutes and companies and in the framework of the European and international research. It will impact also on R&D work for ILC, FEL, and will be complementarity to other large scale accelerator projects. IRIDE is also intended to be realized in subsequent stages of development depending on the assigned priorities.
△ Less
Submitted 30 July, 2013;
originally announced July 2013.