Using Micromegas detectors for direct dark matter searches: challenges and perspectives
Authors:
K. Altenmueller,
. Antolin,
D. Calvet,
F. R. Candon,
J. Castel,
S. Cebrian,
C. Cogollos,
T. Dafni,
D. Diez Ibanez,
E. Ferrer-Ribas,
J. Galan,
J. A. Garcia,
H. Gomez,
Y. Gu,
A. Ezquerro,
I. G Irastorza,
G. Luzon,
C. Margalejo,
H. Mirallas,
L. Obis,
A. Ortiz de Solorzano,
T. Papaevangelou,
O. Perez,
E. Picatoste,
J. Porron
, et al. (5 additional authors not shown)
Abstract:
Gas time projection chambers (TPCs) with Micromegas pixelated readouts are being used in dark matter searches and other rare event searches, due to their potential in terms of low background levels, energy and spatial resolution, gain, and operational stability. Moreover, these detectors can provide precious features,such as topological information, allowing for event directionality and powerful s…
▽ More
Gas time projection chambers (TPCs) with Micromegas pixelated readouts are being used in dark matter searches and other rare event searches, due to their potential in terms of low background levels, energy and spatial resolution, gain, and operational stability. Moreover, these detectors can provide precious features,such as topological information, allowing for event directionality and powerful signal-background discrimination. The Micromegas technology of the microbulk type is particularly suited to low-background applications and is being exploited by detectors for CAST and IAXO (solar axions) and TREX-DM (low-mass WIMPs) experiments. Challenges for the future include reducing intrinsic background levels, reaching lower energy detection levels, and technical issues such as robustness of detector, new design choices, novel gas mixtures and operation points, scaling up to larger detector sizes, handling large readout granularity, etc. We report on the status and prospects of the development ongoing in the context of IAXO and TREX-DM experiments, pointing to promising perspectives for the use of Micromegas detectors in directdark matter searches
△ Less
Submitted 15 April, 2024;
originally announced April 2024.
-
Background discrimination with a Micromegas detector prototype and veto system for BabyIAXO
Authors:
K. Altenmüller,
J. F. Castel,
S. Cebrián,
T. Dafni,
D. Díez-Ibañez,
A. Ezquerro,
E. Ferrer-Ribas,
J. Galan,
J. Galindo,
J. A. García,
A. Giganon,
C. Goblin,
I. G. Irastorza,
C. Loiseau,
G. Luzón,
X. F. Navick,
C. Margalejo,
H. Mirallas,
L. Obis,
A. Ortiz de Solórzano,
T. Papaevangelou,
O. Pérez,
A. Quintana,
J. Ruz,
J. K. Vogel
Abstract:
In this paper we present measurements performed with a Micromegas X-ray detector setup. The detector is a prototype in the context of the BabyIAXO helioscope, which is under construction to search for an emission of the hypothetical axion particle from the sun. An important component of such a helioscope is a low background X-ray detector with a high efficiency in the 1-10 keV energy range. The go…
▽ More
In this paper we present measurements performed with a Micromegas X-ray detector setup. The detector is a prototype in the context of the BabyIAXO helioscope, which is under construction to search for an emission of the hypothetical axion particle from the sun. An important component of such a helioscope is a low background X-ray detector with a high efficiency in the 1-10 keV energy range. The goal of the measurement was to study techniques for background discrimination. In addition to common techniques we used a multi-layer veto system designed to tag cosmogenic neutron background. Over an effective time of 52 days, a background level of $8.6 \times 10^{-7}\,\text{counts keV}^{-1}\,\text{cm}^{-2} \, \text{s}^{-1}$ was reached in a laboratory at above ground level. This is the lowest background level achieved at surface level. In this paper we present the experimental setup, show simulations of the neutron-induced background, and demonstrate the process to identify background signals in the data. Finally, prospects to reach lower background levels down to $10^{-7} \, \text{counts keV}^{-1} \, \text{cm}^{-2} \, \text{s}^{-1}$ will be discussed.
△ Less
Submitted 10 March, 2024;
originally announced March 2024.
-
Searching for WIMPs with TREX-DM: achievements and challenges
Authors:
Juan F. Castel,
Susana Cebrián,
Theopisti Dafni,
David Díez-Ibáñez,
Álvaro Ezquerro,
Javier Galán,
Juan Antonio García,
Igor G. Irastorza,
María Jiménez,
Gloria Luzón,
Cristina Margalejo,
Ángel de Mira,
Hector Mirallas,
Luis Obis,
Alfonso Ortiz de Solórzano,
Oscar Pérez,
Jaime Ruz,
Julia Vogel
Abstract:
The TREX-DM detector, a low background chamber with microbulk Micromegas readout, was commissioned in the underground laboratory of Canfranc (LSC) in 2018. Since then, data taking campaigns have been carried out with Argon and Neon mixtures, at different pressures from 1 to 4 bar. By achieving a low energy threshold of 1 keV$_{ee}$ and a background level of 80 counts keV$^{-1}$ Kg$^{-1}$ day…
▽ More
The TREX-DM detector, a low background chamber with microbulk Micromegas readout, was commissioned in the underground laboratory of Canfranc (LSC) in 2018. Since then, data taking campaigns have been carried out with Argon and Neon mixtures, at different pressures from 1 to 4 bar. By achieving a low energy threshold of 1 keV$_{ee}$ and a background level of 80 counts keV$^{-1}$ Kg$^{-1}$ day$^{-1}$ in the region from 1 to 7 keV$_{ee}$, the experiment demonstrates its potential to search for low-mass WIMPs. Two of the most important challenges currently faced are the reduction of both, background level and energy threshold. With respect to the energy threshold, recently a new readout plane is being developed, based on the combination of Micromegas and GEM technologies, aiming to have a pre-amplification stage that would permit very low energy thresholds, close to the single-electron ionization energy. With respect to the background reduction, apart from studies to identify and minimize contamination population, a high sensitivity alpha detector is being developed in order to allow a proper material selection for the TREX-DM detector components. Both challenges, together with the optimization of the gas mixture used as target for the WIMP detection, will take TREX-DM to explore regions of WIMP's mass below 1 GeV c$^{-2}$.
△ Less
Submitted 19 December, 2023;
originally announced December 2023.