-
Combined Pre-Supernova Alert System with Kamland and Super-Kamiokande
Authors:
KamLAND,
Super-Kamiokande Collaborations,
:,
Seisho Abe,
Minori Eizuka,
Sawako Futagi,
Azusa Gando,
Yoshihito Gando,
Shun Goto,
Takahiko Hachiya,
Kazumi Hata,
Koichi Ichimura,
Sei Ieki,
Haruo Ikeda,
Kunio Inoue,
Koji Ishidoshiro,
Yuto Kamei,
Nanami Kawada,
Yasuhiro Kishimoto,
Masayuki Koga,
Maho Kurasawa,
Tadao Mitsui,
Haruhiko Miyake,
Daisuke Morita,
Takeshi Nakahata
, et al. (290 additional authors not shown)
Abstract:
Preceding a core-collapse supernova, various processes produce an increasing amount of neutrinos of all flavors characterized by mounting energies from the interior of massive stars. Among them, the electron antineutrinos are potentially detectable by terrestrial neutrino experiments such as KamLAND and Super-Kamiokande via inverse beta decay interactions. Once these pre-supernova neutrinos are ob…
▽ More
Preceding a core-collapse supernova, various processes produce an increasing amount of neutrinos of all flavors characterized by mounting energies from the interior of massive stars. Among them, the electron antineutrinos are potentially detectable by terrestrial neutrino experiments such as KamLAND and Super-Kamiokande via inverse beta decay interactions. Once these pre-supernova neutrinos are observed, an early warning of the upcoming core-collapse supernova can be provided. In light of this, KamLAND and Super-Kamiokande, both located in the Kamioka mine in Japan, have been monitoring pre-supernova neutrinos since 2015 and 2021, respectively. Recently, we performed a joint study between KamLAND and Super-Kamiokande on pre-supernova neutrino detection. A pre-supernova alert system combining the KamLAND detector and the Super-Kamiokande detector was developed and put into operation, which can provide a supernova alert to the astrophysics community. Fully leveraging the complementary properties of these two detectors, the combined alert is expected to resolve a pre-supernova neutrino signal from a 15 M$_{\odot}$ star within 510 pc of the Earth, at a significance level corresponding to a false alarm rate of no more than 1 per century. For a Betelgeuse-like model with optimistic parameters, it can provide early warnings up to 12 hours in advance.
△ Less
Submitted 1 July, 2024; v1 submitted 15 April, 2024;
originally announced April 2024.
-
Characterization of Charge Spreading and Gain of Encapsulated Resistive Micromegas Detectors for the Upgrade of the T2K Near Detector Time Projection Chambers
Authors:
D. Attie,
O. Ballester,
M. Batkiewicz-Kwasnia,
P. Billoir,
A. Blondel,
S. Bolognesi,
R. Boullon,
D. Calvet,
M. P. Casado,
M. G. Catanesi,
M. Cicerchia,
G. Cogo,
P. Colas,
G. Collazuol,
D. D Ago,
C. Dalmazzon,
T. Daret,
A. Delbart,
A. De Lorenzis,
R. de Oliveira,
S. Dolan,
K. Dygnarowiczi,
J. Dumarchez,
S. Emery-Schren,
A. Ershova
, et al. (70 additional authors not shown)
Abstract:
An upgrade of the near detector of the T2K long baseline neutrino oscillation experiment is currently being conducted. This upgrade will include two new Time Projection Chambers, each equipped with 16 charge readout resistive Micromegas modules. A procedure to validate the performance of the detectors at different stages of production has been developed and implemented to ensure a proper and relia…
▽ More
An upgrade of the near detector of the T2K long baseline neutrino oscillation experiment is currently being conducted. This upgrade will include two new Time Projection Chambers, each equipped with 16 charge readout resistive Micromegas modules. A procedure to validate the performance of the detectors at different stages of production has been developed and implemented to ensure a proper and reliable operation of the detectors once installed. A dedicated X-ray test bench is used to characterize the detectors by scanning each pad individually and to precisely measure the uniformity of the gain and the deposited energy resolution over the pad plane. An energy resolution of about 10% is obtained. A detailed physical model has been developed to describe the charge dispersion phenomena in the resistive Micromegas anode. The detailed physical description includes initial ionization, electron drift, diffusion effects and the readout electronics effects. The model provides an excellent characterization of the charge spreading of the experimental measurements and allowed the simultaneous extraction of gain and RC information of the modules.
△ Less
Submitted 8 March, 2023;
originally announced March 2023.
-
Analysis of test beam data taken with a prototype of TPC with resistive Micromegas for the T2K Near Detector upgrade
Authors:
D. Attié,
O. Ballester,
M. Batkiewicz-Kwasniak,
P. Billoir,
A. Blanchet,
A. Blondel,
S. Bolognesi,
R. Boullon,
D. Calvet,
M. P. Casado,
M. G. Catanesi,
M. Cicerchia,
G. Cogo,
P. Colas,
G. Collazuol,
C. Dalmazzone,
T. Daret,
A. Delbart,
A. De Lorenzis,
S. Dolan,
K. Dygnarowicz,
J. Dumarchez,
S. Emery-Schrenk,
A. Ershova,
G. Eurin
, et al. (59 additional authors not shown)
Abstract:
In this paper we describe the performance of a prototype of the High Angle Time Projection Chambers (HA-TPCs) that are being produced for the Near Detector (ND280) upgrade of the T2K experiment. The two HA-TPCs of ND280 will be instrumented with eight Encapsulated Resistive Anode Micromegas (ERAM) on each endplate, thus constituting in total 32 ERAMs. This innovative technique allows the detection…
▽ More
In this paper we describe the performance of a prototype of the High Angle Time Projection Chambers (HA-TPCs) that are being produced for the Near Detector (ND280) upgrade of the T2K experiment. The two HA-TPCs of ND280 will be instrumented with eight Encapsulated Resistive Anode Micromegas (ERAM) on each endplate, thus constituting in total 32 ERAMs. This innovative technique allows the detection of the charge emitted by ionization electrons over several pads, improving the determination of the track position. The TPC prototype has been equipped with the first ERAM module produced for T2K and with the HA-TPC readout electronics chain and it has been exposed to the DESY Test Beam in order to measure spatial and dE/dx resolution. In this paper we characterize the performances of the ERAM and, for the first time, we compare them with a newly developed simulation of the detector response. Spatial resolution better than 800 ${μ\rm m}$ and dE/dx resolution better than 10% are observed for all the incident angles and for all the drift distances of interest. All the main features of the data are correctly reproduced by the simulation and these performances fully fulfill the requirements for the HA-TPCs of T2K.
△ Less
Submitted 16 May, 2023; v1 submitted 13 December, 2022;
originally announced December 2022.
-
Characterization of resistive Micromegas detectors for the upgrade of the T2K Near Detector Time Projection Chambers
Authors:
D. Attié,
M. Batkiewicz-Kwasniak,
P. Billoir,
A. Blanchet,
A. Blondel,
S. Bolognesi,
D. Calvet,
M. G. Catanesi,
M. Cicerchia,
G. Cogo,
P. Colas,
G. Collazuol,
A. Delbart,
J. Dumarchez,
S. Emery-Schrenk,
M. Feltre,
C. Giganti,
F. Gramegna,
M. Grassi,
M. Guigue,
P. Hamacher-Baumann,
S. Hassani,
F. Iacob,
C. Jesús-Valls,
R. Kurjata
, et al. (36 additional authors not shown)
Abstract:
The second phase of the T2K experiment is expected to start data taking in autumn 2022. An upgrade of the Near Detector (ND280) is under development and includes the construction of two new Time Projection Chambers called High-Angle TPC (HA-TPC). The two endplates of these TPCs will be paved with eight Micromegas type charge readout modules. The Micromegas detector charge amplification structure u…
▽ More
The second phase of the T2K experiment is expected to start data taking in autumn 2022. An upgrade of the Near Detector (ND280) is under development and includes the construction of two new Time Projection Chambers called High-Angle TPC (HA-TPC). The two endplates of these TPCs will be paved with eight Micromegas type charge readout modules. The Micromegas detector charge amplification structure uses a resistive anode to spread the charges over several pads to improve the space point resolution. This innovative technique is combined with the bulk-Micromegas technology to compose the "Encapsulated Resistive Anode Micromegas" detector. A prototype has been designed, built and exposed to an electron beam at the DESY II test beam facility.
The data have been used to characterize the charge spreading and to produce a RC map. Spatial resolution better than 600 $μ$m and energy resolution better than 9% are obtained for all incident angles. These performances fulfil the requirements for the upgrade of the ND280 TPC.
△ Less
Submitted 23 June, 2021;
originally announced June 2021.