Development of a method to measure trace level of uranium and thorium in scintillation films
Authors:
K. Ichimura,
K. Chiba,
Y. Gando,
H. Ikeda,
Y. Kishimoto,
M. Kurasawa,
K. Nemoto,
A. Sakaguchi,
Y. Takaku,
Y. Sakakieda
Abstract:
We have established a method to measure picograms-per-gram (pg g$^{-1}$) levels of $^{238}$U and $^{232}$Th in scintillation films by combining the dry ashing method and inductively coupled plasma mass spectrometry. Trace amounts of $^{238}$U and $^{232}$Th were measured in up to 2~g of the scintillation film with almost 100% collection efficiency. This paper details the experimental procedure, in…
▽ More
We have established a method to measure picograms-per-gram (pg g$^{-1}$) levels of $^{238}$U and $^{232}$Th in scintillation films by combining the dry ashing method and inductively coupled plasma mass spectrometry. Trace amounts of $^{238}$U and $^{232}$Th were measured in up to 2~g of the scintillation film with almost 100% collection efficiency. This paper details the experimental procedure, including the pretreatment of the samples and labware, detection limit of the method, collection efficiencies of $^{238}$U and $^{232}$Th, and measurement of $^{238}$U and $^{232}$Th in a polyethylene naphthalate film. This method is also applicable to $^{238}$U and $^{232}$Th measurements in other low-background organic materials for rare event search experiments.
△ Less
Submitted 8 May, 2024;
originally announced May 2024.
-
Combined Pre-Supernova Alert System with Kamland and Super-Kamiokande
Authors:
KamLAND,
Super-Kamiokande Collaborations,
:,
Seisho Abe,
Minori Eizuka,
Sawako Futagi,
Azusa Gando,
Yoshihito Gando,
Shun Goto,
Takahiko Hachiya,
Kazumi Hata,
Koichi Ichimura,
Sei Ieki,
Haruo Ikeda,
Kunio Inoue,
Koji Ishidoshiro,
Yuto Kamei,
Nanami Kawada,
Yasuhiro Kishimoto,
Masayuki Koga,
Maho Kurasawa,
Tadao Mitsui,
Haruhiko Miyake,
Daisuke Morita,
Takeshi Nakahata
, et al. (290 additional authors not shown)
Abstract:
Preceding a core-collapse supernova, various processes produce an increasing amount of neutrinos of all flavors characterized by mounting energies from the interior of massive stars. Among them, the electron antineutrinos are potentially detectable by terrestrial neutrino experiments such as KamLAND and Super-Kamiokande via inverse beta decay interactions. Once these pre-supernova neutrinos are ob…
▽ More
Preceding a core-collapse supernova, various processes produce an increasing amount of neutrinos of all flavors characterized by mounting energies from the interior of massive stars. Among them, the electron antineutrinos are potentially detectable by terrestrial neutrino experiments such as KamLAND and Super-Kamiokande via inverse beta decay interactions. Once these pre-supernova neutrinos are observed, an early warning of the upcoming core-collapse supernova can be provided. In light of this, KamLAND and Super-Kamiokande, both located in the Kamioka mine in Japan, have been monitoring pre-supernova neutrinos since 2015 and 2021, respectively. Recently, we performed a joint study between KamLAND and Super-Kamiokande on pre-supernova neutrino detection. A pre-supernova alert system combining the KamLAND detector and the Super-Kamiokande detector was developed and put into operation, which can provide a supernova alert to the astrophysics community. Fully leveraging the complementary properties of these two detectors, the combined alert is expected to resolve a pre-supernova neutrino signal from a 15 M$_{\odot}$ star within 510 pc of the Earth, at a significance level corresponding to a false alarm rate of no more than 1 per century. For a Betelgeuse-like model with optimistic parameters, it can provide early warnings up to 12 hours in advance.
△ Less
Submitted 1 July, 2024; v1 submitted 15 April, 2024;
originally announced April 2024.
-
Search for Charged Excited States of Dark Matter with KamLAND-Zen
Authors:
KamLAND-Zen collaboration,
:,
S. Abe,
M. Eizuka,
S. Futagi,
A. Gando,
Y. Gando,
S. Goto,
T. Hachiya,
K. Hata,
K. Hosokawa,
K. Ichimura,
S. Ieki,
H. Ikeda,
K. Inoue,
K. Ishidoshiro,
Y. Kamei,
N. Kawada,
Y. Kishimoto,
M. Koga,
M. Kurasawa,
T. Mitsui,
H. Miyake,
D. Morita,
T. Nakahata
, et al. (44 additional authors not shown)
Abstract:
Particle dark matter could belong to a multiplet that includes an electrically charged state. WIMP dark matter ($χ^{0}$) accompanied by a negatively charged excited state ($χ^{-}$) with a small mass difference (e.g. $<$ 20 MeV) can form a bound-state with a nucleus such as xenon. This bound-state formation is rare and the released energy is $\mathcal{O}(1-10$) MeV depending on the nucleus, making…
▽ More
Particle dark matter could belong to a multiplet that includes an electrically charged state. WIMP dark matter ($χ^{0}$) accompanied by a negatively charged excited state ($χ^{-}$) with a small mass difference (e.g. $<$ 20 MeV) can form a bound-state with a nucleus such as xenon. This bound-state formation is rare and the released energy is $\mathcal{O}(1-10$) MeV depending on the nucleus, making large liquid scintillator detectors suitable for detection. We searched for bound-state formation events with xenon in two experimental phases of the KamLAND-Zen experiment, a xenon-doped liquid scintillator detector. No statistically significant events were observed. For a benchmark parameter set of WIMP mass $m_{χ^{0}} = 1$ TeV and mass difference $Δm = 17$ MeV, we set the most stringent upper limits on the recombination cross section times velocity $\langleσv\rangle$ and the decay-width of $χ^{-}$ to $9.2 \times 10^{-30}$ ${\rm cm^3/s}$ and $8.7 \times 10^{-14}$ GeV, respectively at 90% confidence level.
△ Less
Submitted 3 July, 2024; v1 submitted 16 November, 2023;
originally announced November 2023.
-
Development of a low-background HPGe detector at Kamioka Observatory
Authors:
K. Ichimura,
H. Ikeda,
Y. Kishimoto,
M. Kurasawa,
A. A. Suzuki,
Y. Gando,
M. Ikeda,
K. Hosokawa,
H. Sekiya,
H. Ito,
A. Minamino,
S. Suzuki
Abstract:
A new ultra-low background high-purity germanium (HPGe) detector has been installed at the Kamioka underground experimental site. The background count rate in the energy range from 40 keV to 2700 keV is about 25% lower than that of the first HPGe detector installed in 2016, which has the same detector specification and similar shielding geometry. This paper describes the shielding configuration, i…
▽ More
A new ultra-low background high-purity germanium (HPGe) detector has been installed at the Kamioka underground experimental site. The background count rate in the energy range from 40 keV to 2700 keV is about 25% lower than that of the first HPGe detector installed in 2016, which has the same detector specification and similar shielding geometry. This paper describes the shielding configuration, including the cleaning of the material surface, the comparison of calibration data and simulation, the time variation of the background spectra, the sample measurement procedure, and some results of the radioactivity in the selected samples.
△ Less
Submitted 4 December, 2023; v1 submitted 9 August, 2023;
originally announced August 2023.
-
Measurement of cosmic-ray muon spallation products in a xenon-loaded liquid scintillator with KamLAND
Authors:
KamLAND-Zen Collaboration,
:,
S. Abe,
S. Asami,
M. Eizuka,
S. Futagi,
A. Gando,
Y. Gando,
T. Gima,
A. Goto,
T. Hachiya,
K. Hata,
K. Hosokawa,
K. Ichimura,
S. Ieki,
H. Ikeda,
K. Inoue,
K. Ishidoshiro,
Y. Kamei,
N. Kawada,
Y. Kishimoto,
M. Koga,
M. Kurasawa,
T. Mitsui,
H. Miyake
, et al. (42 additional authors not shown)
Abstract:
Cosmic-ray muons produce various radioisotopes when passing through material. These spallation products can be backgrounds for rare event searches such as in solar neutrino, double-beta decay, and dark matter search experiments. The KamLAND-Zen experiment searches for neutrinoless double-beta decay in 745kg of xenon dissolved in liquid scintillator. The experiment includes dead-time-free electroni…
▽ More
Cosmic-ray muons produce various radioisotopes when passing through material. These spallation products can be backgrounds for rare event searches such as in solar neutrino, double-beta decay, and dark matter search experiments. The KamLAND-Zen experiment searches for neutrinoless double-beta decay in 745kg of xenon dissolved in liquid scintillator. The experiment includes dead-time-free electronics with a high efficiency for detecting muon-induced neutrons. The production yields of different radioisotopes are measured with a combination of delayed coincidence techniques, newly developed muon reconstruction and xenon spallation identification methods. The observed xenon spallation products are consistent with results from the FLUKA and Geant4 simulation codes.
△ Less
Submitted 23 January, 2023;
originally announced January 2023.
-
Direct dark matter searches with the full data set of XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
N. Kato,
S. Moriyama,
M. Nakahata,
K. Sato,
H. Sekiya,
T. Suzuki,
Y. Suzuki,
A. Takeda,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. H. Kim,
Y. Itow,
K. Martens,
A. Mason,
M. Yamashita,
K. Miuchi,
Y. Takeuchi,
K. B. Lee,
M. K. Lee,
Y. Fukuda,
H. Ogawa
, et al. (7 additional authors not shown)
Abstract:
Various WIMP dark matter searches using the full data set of XMASS-I, a single-phase liquid xenon detector, are reported in this paper. Stable XMASS-I data taking accumulated a total live time of 1590.9 days between November 20, 2013 and February 1, 2019 with an analysis threshold of ${\rm 1.0\,keV_{ee}}$. In the latter half of data taking a lower analysis threshold of ${\rm 0.5\,keV_{ee}}$ was al…
▽ More
Various WIMP dark matter searches using the full data set of XMASS-I, a single-phase liquid xenon detector, are reported in this paper. Stable XMASS-I data taking accumulated a total live time of 1590.9 days between November 20, 2013 and February 1, 2019 with an analysis threshold of ${\rm 1.0\,keV_{ee}}$. In the latter half of data taking a lower analysis threshold of ${\rm 0.5\,keV_{ee}}$ was also available through a new low threshold trigger. Searching for a WIMP signal in the detector's 97~kg fiducial volume yielded a limit on the WIMP-nucleon scattering cross section of ${\rm 1.4\times 10^{-44}\, cm^{2}}$ for a ${\rm 60\,GeV/c^{2}}$ WIMP at the 90$\%$ confidence level. We also searched for WIMP induced annual modulation signatures in the detector's whole target volume, containing 832~kg of liquid xenon. For nuclear recoils of a ${\rm 8\,GeV/c^{2}}$ WIMP this analysis yielded a 90\% CL cross section limit of ${\rm 2.3\times 10^{-42}\, cm^{2}}$. At a WIMP mass of ${\rm 0.5\, GeV/c^{2}}$ the Migdal effect and Bremsstrahlung signatures were evaluated and lead to 90\% CL cross section limits of ${\rm 1.4\times 10^{-35}\, cm^{2}}$ and ${\rm 1.1\times 10^{-33}\, cm^{2}}$ respectively.
△ Less
Submitted 1 September, 2023; v1 submitted 11 November, 2022;
originally announced November 2022.
-
Neutron Tagging following Atmospheric Neutrino Events in a Water Cherenkov Detector
Authors:
K. Abe,
Y. Haga,
Y. Hayato,
K. Hiraide,
K. Ieki,
M. Ikeda,
S. Imaizumi,
K. Iyogi,
J. Kameda,
Y. Kanemura,
Y. Kataoka,
Y. Kato,
Y. Kishimoto,
S. Miki,
S. Mine,
M. Miura,
T. Mochizuki,
S. Moriyama,
Y. Nagao,
M. Nakahata,
T. Nakajima,
Y. Nakano,
S. Nakayama,
T. Okada,
K. Okamoto
, et al. (281 additional authors not shown)
Abstract:
We present the development of neutron-tagging techniques in Super-Kamiokande IV using a neural network analysis. The detection efficiency of neutron capture on hydrogen is estimated to be 26%, with a mis-tag rate of 0.016 per neutrino event. The uncertainty of the tagging efficiency is estimated to be 9.0%. Measurement of the tagging efficiency with data from an Americium-Beryllium calibration agr…
▽ More
We present the development of neutron-tagging techniques in Super-Kamiokande IV using a neural network analysis. The detection efficiency of neutron capture on hydrogen is estimated to be 26%, with a mis-tag rate of 0.016 per neutrino event. The uncertainty of the tagging efficiency is estimated to be 9.0%. Measurement of the tagging efficiency with data from an Americium-Beryllium calibration agrees with this value within 10%. The tagging procedure was performed on 3,244.4 days of SK-IV atmospheric neutrino data, identifying 18,091 neutrons in 26,473 neutrino events. The fitted neutron capture lifetime was measured as 218 \pm 9 μs.
△ Less
Submitted 20 September, 2022; v1 submitted 18 September, 2022;
originally announced September 2022.
-
Development of Ultra-pure Gadolinium Sulfate for the Super-Kamiokande Gadolinium Project
Authors:
K. Hosokawa,
M. Ikeda,
T. Okada,
H. Sekiya,
P. Fernandez,
L. Labarga,
I. Bandac,
J. Perez,
S. Ito,
M. Harada,
Y. Koshio,
M. D. Thiesse,
L. F. Thompson,
P. R. Scovell,
E. Meehan,
K. Ichimura,
Y. Kishimoto,
Y. Nakajima,
M. R. Vagins,
H. Ito,
Y. Takaku,
Y. Tanaka,
Y. Yamaguchi
Abstract:
This paper reports the development and detailed properties of about 13 tons of gadolinium sulfate octahydrate, $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$, which has been dissolved into Super-Kamiokande (SK) in the summer of 2020. We evaluate the impact of radioactive impurities in $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$ on DSNB searches and solar neutrino observation and confirm the need to reduce radioa…
▽ More
This paper reports the development and detailed properties of about 13 tons of gadolinium sulfate octahydrate, $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$, which has been dissolved into Super-Kamiokande (SK) in the summer of 2020. We evaluate the impact of radioactive impurities in $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$ on DSNB searches and solar neutrino observation and confirm the need to reduce radioactive and fluorescent impurities by about three orders of magnitude from commercially available high-purity $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$. In order to produce ultra-high-purity $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$, we have developed a method to remove impurities from gadolinium oxide, Gd$_2$O$_3$, consisting of acid dissolution, solvent extraction, and pH control processes, followed by a high-purity sulfation process. All of the produced ultra-high-purity $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$ is assayed by ICP-MS and HPGe detectors to evaluate its quality. Because of the long measurement time of HPGe detectors, we have employed several underground laboratories for making parallel measurements including LSC in Spain, Boulby in the UK, and Kamioka in Japan. In the first half of production, the measured batch purities were found to be consistent with the specifications. However,in the latter half, the $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$ contained one order of magnitude more $^{228}$Ra than the budgeted mean contamination. This was correlated with the corresponding characteristics of the raw material Gd$_2$O$_3$, in which an intrinsically large contamination was present. Based on their modest impact on SK physics, they were nevertheless introduced into the detector. To reduce $^{228}$Ra for the next stage of Gd loading to SK, a new process has been successfully establised.
△ Less
Submitted 13 September, 2022;
originally announced September 2022.
-
Abundances of uranium and thorium elements in Earth estimated by geoneutrino spectroscopy
Authors:
S. Abe,
S. Asami,
M. Eizuka,
S. Futagi,
A. Gando,
Y. Gando,
T. Gima,
A. Goto,
T. Hachiya,
K. Hata,
K. Hosokawa,
K. Ichimura,
S. Ieki,
H. Ikeda,
K. Inoue,
K. Ishidoshiro,
Y. Kamei,
N. Kawada,
Y. Kishimoto,
M. Koga,
M. Kurasawa,
N. Maemura,
T. Mitsui,
H. Miyake,
T. Nakahata
, et al. (43 additional authors not shown)
Abstract:
The decay of the primordial isotopes $^{238}\mathrm{U}$, $^{235}\mathrm{U}$, $^{232}\mathrm{Th}$, and $^{40}\mathrm{K}$ have contributed to the terrestrial heat budget throughout the Earth's history. Hence the individual abundance of those isotopes are key parameters in reconstructing contemporary Earth model. The geoneutrinos produced by the radioactive decays of uranium and thorium have been obs…
▽ More
The decay of the primordial isotopes $^{238}\mathrm{U}$, $^{235}\mathrm{U}$, $^{232}\mathrm{Th}$, and $^{40}\mathrm{K}$ have contributed to the terrestrial heat budget throughout the Earth's history. Hence the individual abundance of those isotopes are key parameters in reconstructing contemporary Earth model. The geoneutrinos produced by the radioactive decays of uranium and thorium have been observed with the Kamioka Liquid-Scintillator Antineutrino Detector (KamLAND). Those measurements have been improved with more than 18-year observation time, and improvements in detector background levels mainly by an 8-year almost rector-free period now permit spectroscopy with geoneutrinos. Our results yield the first constraint on both uranium and thorium heat contributions. Herein the KamLAND result is consistent with geochemical estimations based on elemental abundances of chondritic meteorites and mantle peridotites. The High-Q model is disfavored at 99.76% C.L. and a fully radiogenic model is excluded at 5.2$σ$ assuming a homogeneous heat producing element distribution in the mantle.
△ Less
Submitted 13 August, 2022; v1 submitted 30 May, 2022;
originally announced May 2022.
-
Search for neutrinoless quadruple beta decay of $^{136}$Xe in XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
N. Kato,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
K. Sato,
H. Sekiya,
T. Suzuki,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. H. Kim,
R. Ishii,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens
, et al. (12 additional authors not shown)
Abstract:
A search for the neutrinoless quadruple beta decay of $^{136}$Xe was conducted with the liquid-xenon detector XMASS-I using $\rm 327\; kg \times 800.0 \; days$ of the exposure. The pulse shape discrimination based on the scintillation decay time constant which distinguishes $γ$-rays including the signal and $β$-rays was used to enhance the search sensitivity. No significant signal excess was obser…
▽ More
A search for the neutrinoless quadruple beta decay of $^{136}$Xe was conducted with the liquid-xenon detector XMASS-I using $\rm 327\; kg \times 800.0 \; days$ of the exposure. The pulse shape discrimination based on the scintillation decay time constant which distinguishes $γ$-rays including the signal and $β$-rays was used to enhance the search sensitivity. No significant signal excess was observed from the energy spectrum fitting with precise background evaluation, and we set a lower limit of the half life of 3.7 $\times$ 10$^{24}$ years at 90$\%$ confidence level. This is the first experimental constraint of the neutrinoless quadruple beta decay of $^{136}$Xe.
△ Less
Submitted 5 August, 2022; v1 submitted 10 May, 2022;
originally announced May 2022.
-
Search for the Majorana Nature of Neutrinos in the Inverted Mass Ordering Region with KamLAND-Zen
Authors:
KamLAND-Zen Collaboration,
:,
S. Abe,
S. Asami,
M. Eizuka,
S. Futagi,
A. Gando,
Y. Gando,
T. Gima,
A. Goto,
T. Hachiya,
K. Hata,
S. Hayashida,
K. Hosokawa,
K. Ichimura,
S. Ieki,
H. Ikeda,
K. Inoue,
K. Ishidoshiro,
Y. Kamei,
N. Kawada,
Y. Kishimoto,
M. Koga,
M. Kurasawa,
N. Maemura
, et al. (50 additional authors not shown)
Abstract:
The KamLAND-Zen experiment has provided stringent constraints on the neutrinoless double-beta ($0νββ$) decay half-life in $^{136}$Xe using a xenon-loaded liquid scintillator. We report an improved search using an upgraded detector with almost double the amount of xenon and an ultralow radioactivity container, corresponding to an exposure of 970 kg yr of $^{136}$Xe. These new data provide valuable…
▽ More
The KamLAND-Zen experiment has provided stringent constraints on the neutrinoless double-beta ($0νββ$) decay half-life in $^{136}$Xe using a xenon-loaded liquid scintillator. We report an improved search using an upgraded detector with almost double the amount of xenon and an ultralow radioactivity container, corresponding to an exposure of 970 kg yr of $^{136}$Xe. These new data provide valuable insight into backgrounds, especially from cosmic muon spallation of xenon, and have required the use of novel background rejection techniques. We obtain a lower limit for the $0νββ$ decay half-life of $T_{1/2}^{0ν} > 2.3 \times 10^{26}$ yr at 90% C.L., corresponding to upper limits on the effective Majorana neutrino mass of 36-156 meV using commonly adopted nuclear matrix element calculations.
△ Less
Submitted 16 February, 2023; v1 submitted 4 March, 2022;
originally announced March 2022.
-
Search for event bursts in XMASS-I associated with gravitational-wave events
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
T. Suzuki,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki,
B. D. Xu
, et al. (12 additional authors not shown)
Abstract:
We performed a search for event bursts in the XMASS-I detector associated with 11 gravitational-wave events detected during LIGO/Virgo's O1 and O2 periods. Simple and loose cuts were applied to the data collected in the full 832 kg xenon volume around the detection time of each gravitational-wave event. The data were divided into four energy regions ranging from keV to MeV. Without assuming any pa…
▽ More
We performed a search for event bursts in the XMASS-I detector associated with 11 gravitational-wave events detected during LIGO/Virgo's O1 and O2 periods. Simple and loose cuts were applied to the data collected in the full 832 kg xenon volume around the detection time of each gravitational-wave event. The data were divided into four energy regions ranging from keV to MeV. Without assuming any particular burst models, we looked for event bursts in sliding windows with various time width from 0.02 to 10 s. The search was conducted in a time window between $-$400 and $+$10,000 s from each gravitational-wave event. For the binary neutron star merger GW170817, no significant event burst was observed in the XMASS-I detector and we set 90% confidence level upper limits on neutrino fluence for the sum of all the neutrino flavors via coherent elastic neutrino-nucleus scattering. The obtained upper limit was (1.3-2.1)$\times 10^{11}$ cm$^{-2}$ under the assumption of a Fermi-Dirac spectrum with average neutrino energy of 20 MeV. The neutrino fluence limits for mono-energetic neutrinos in the energy range between 14 and 100 MeV were also calculated. Among the other 10 gravitational wave events detected as the binary black hole mergers, a burst candidate with a 3.0$σ$ significance was found at 1801.95-1803.95 s in the analysis for GW151012. However, no significant deviation from the background in the reconstructed energy and position distributions was found. Considering the additional look-elsewhere effect of analyzing the 11 GW events, the significance of finding such a burst candidate associated with any of them is 2.1$σ$.
△ Less
Submitted 30 December, 2020; v1 submitted 29 July, 2020;
originally announced July 2020.
-
Improved method for measuring low concentration radium and its application to the Super-Kamiokande Gadolinium project
Authors:
S. Ito,
K. Ichimura,
Y. Takaku,
K. Abe,
M. Harada,
M. Ikeda,
H. Ito,
Y. Kishimoto,
Y. Nakajima,
T. Okada,
H. Sekiya
Abstract:
Chemical extraction using a molecular recognition resin named "Empore Radium Rad Disk" was developed to improve sensitivity for the low concentration of radium (Ra). Compared with the previous method, the extraction process speed was improved by a factor of three and the recovery rate for $^{226}$Ra was also improved from 81$\pm$4% to $>$99.9%. The sensitivity on the 10$^{-1}$ mBq level was achiev…
▽ More
Chemical extraction using a molecular recognition resin named "Empore Radium Rad Disk" was developed to improve sensitivity for the low concentration of radium (Ra). Compared with the previous method, the extraction process speed was improved by a factor of three and the recovery rate for $^{226}$Ra was also improved from 81$\pm$4% to $>$99.9%. The sensitivity on the 10$^{-1}$ mBq level was achieved using a high purity germanium detector. This improved method was applied to determine $^{226}$Ra in Gd$_2$(SO$_4$)$_3{\cdot}$8H$_2$O which will be used in the Super-Kamiokande Gadolinium project. The improvement and measurement results are reported in this paper.
△ Less
Submitted 17 June, 2020;
originally announced June 2020.
-
Development of low-background photomultiplier tubes for liquid xenon detectors
Authors:
XMASS Collaboration,
K. Abe,
Y. Chen,
K. Hiraide,
K. Ichimura,
S. Imaizumi,
N. Kato,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
K. Sato,
H. Sekiya,
T. Suzuki,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. H. Kim,
R. Ishii,
Y. Itow,
K. Kanzawa
, et al. (14 additional authors not shown)
Abstract:
We successfully developed a new photomultiplier tube (PMT) with a three-inch diameter, convex-shaped photocathode, R13111. Its prominent features include good performance and ultra-low radioactivity. The convex-shaped photocathode realized a large photon acceptance and good timing resolution. Low radioactivity was achieved by three factors: (1) the glass material was synthesized using low-radioact…
▽ More
We successfully developed a new photomultiplier tube (PMT) with a three-inch diameter, convex-shaped photocathode, R13111. Its prominent features include good performance and ultra-low radioactivity. The convex-shaped photocathode realized a large photon acceptance and good timing resolution. Low radioactivity was achieved by three factors: (1) the glass material was synthesized using low-radioactive-contamination material; (2) the photocathode was produced with $^{39}$K-enriched potassium; and (3) the purest grade of aluminum material was used for the vacuum seal. As a result each R13111 PMT contains only about 0.4 mBq of $^{226}$Ra, less than 2 mBq of $^{238}$U, 0.3 mBq of $^{228}$Ra, 2 mBq of $^{40}$K and 0.2 mBq of $^{60}$Co. We also examined and resolved the intrinsic leakage of Xe gas into PMTs that was observed in several older models. We thus succeeded in developing a PMT that has low background, large angular acceptance with high collection efficiency, good timing resolution, and long-term stable operation. These features are highly desirable for experiments searching for rare events beyond the standard model, such as dark matter particle interactions and neutrinoless double beta decay events.
△ Less
Submitted 18 August, 2020; v1 submitted 1 June, 2020;
originally announced June 2020.
-
Evaluation of Gadolinium's Action on Water Cherenkov Detector Systems with EGADS
Authors:
Ll. Marti,
M. Ikeda,
Y. Kato,
Y. Kishimoto,
M. Nakahata,
Y. Nakajima,
Y. Nakano,
S. Nakayama,
Y. Okajima,
A. Orii,
G. Pronost,
H. Sekiya,
M. Shiozawa,
H. Tanaka,
K. Ueno,
S. Yamada,
T. Yano,
T. Yokozawa,
M. Murdoch,
J. Schuemann,
M. R. Vagins,
K. Bays,
G. Carminati,
N. J. Griskevich,
W. R. Kropp
, et al. (43 additional authors not shown)
Abstract:
Used for both proton decay searches and neutrino physics, large water Cherenkov (WC) detectors have been very successful tools in particle physics. They are notable for their large masses and charged particle detection capabilities. While current WC detectors reconstruct charged particle tracks over a wide energy range, they cannot efficiently detect neutrons. Gadolinium (Gd) has the largest therm…
▽ More
Used for both proton decay searches and neutrino physics, large water Cherenkov (WC) detectors have been very successful tools in particle physics. They are notable for their large masses and charged particle detection capabilities. While current WC detectors reconstruct charged particle tracks over a wide energy range, they cannot efficiently detect neutrons. Gadolinium (Gd) has the largest thermal neutron capture cross section of all stable nuclei and produces an 8 MeV gamma cascade that can be detected with high efficiency. Because of the many new physics opportunities that neutron tagging with a Gd salt dissolved in water would open up, a large-scale R&D program called EGADS was established to demonstrate this technique's feasibility. EGADS features all the components of a WC detector, chiefly a 200-ton stainless steel water tank furnished with 240 photo-detectors, DAQ, and a water system that removes all impurities in water while keeping Gd in solution. In this paper we discuss the milestones towards demonstrating the feasibility of this novel technique, and the features of EGADS in detail.
△ Less
Submitted 26 February, 2020; v1 submitted 30 August, 2019;
originally announced August 2019.
-
Development of a method for measuring rare earth elements in the environment for future experiments with gadolinium loaded detectors
Authors:
S. Ito,
T. Okada,
Y. Takaku,
M. Harada,
M. Ikdeda,
Y. Kishimoto,
Y. Koshio,
M. Nakahata,
Y. Nakajima,
H. Sekiya
Abstract:
Demand to use gadolinium (Gd) in detectors is increasing in the field of elementary particle physics, especially neutrino measurements and dark matter searches. Large amounts of Gd are used in these experiments. Therefore, to access the impacts of Gd onto the environments, it is becoming important to measure the baseline concentrations of Gd in the environments. The measurement of the baseline con…
▽ More
Demand to use gadolinium (Gd) in detectors is increasing in the field of elementary particle physics, especially neutrino measurements and dark matter searches. Large amounts of Gd are used in these experiments. Therefore, to access the impacts of Gd onto the environments, it is becoming important to measure the baseline concentrations of Gd in the environments. The measurement of the baseline concentrations, however, is not easy due to interferences by other elements. In this paper, a method for measuring the concentrations of rare earth elements including Gd is proposed. In the method, an inductively coupled plasma-mass spectrometry is utilized after collecting the dissolved elements in chelating resin. Results of the ability to detect anomalous concentrations of rare earth elements in river water samples in the Kamioka and Toyama areas are also reported.
△ Less
Submitted 26 May, 2019;
originally announced May 2019.
-
A measurement of the scintillation decay time constant of nuclear recoils in liquid xenon with the XMASS-I detector
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
T. Suzuki,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki
, et al. (13 additional authors not shown)
Abstract:
We report an in-situ measurement of the nuclear recoil (NR) scintillation decay time constant in liquid xenon (LXe) using the XMASS-I detector at the Kamioka underground laboratory in Japan. XMASS-I is a large single-phase LXe scintillation detector whose purpose is the direct detection of dark matter via NR which can be induced by collisions between Weakly Interacting Massive Particles (WIMPs) an…
▽ More
We report an in-situ measurement of the nuclear recoil (NR) scintillation decay time constant in liquid xenon (LXe) using the XMASS-I detector at the Kamioka underground laboratory in Japan. XMASS-I is a large single-phase LXe scintillation detector whose purpose is the direct detection of dark matter via NR which can be induced by collisions between Weakly Interacting Massive Particles (WIMPs) and a xenon nucleus. The inner detector volume contains 832 kg of LXe.
$^{252}$Cf was used as an external neutron source for irradiating the detector. The scintillation decay time constant of the resulting neutron induced NR was evaluated by comparing the observed photon detection times with Monte Carlo simulations. Fits to the decay time prefer two decay time components, one for each of the Xe$_{2}^{*}$ singlet and triplet states, with $τ_{S}$ = 4.3$\pm$0.6 ns taken from prior research, $τ_{T}$ was measured to be 26.9$^{+0.7}_{-1.1}$ ns with a singlet state fraction F$_{S}$ of 0.252$^{+0.027}_{-0.019}$.We also evaluated the performance of pulse shape discrimination between NR and electron recoil (ER) with the aim of reducing the electromagnetic background in WIMP searches. For a 50\% NR acceptance, the ER acceptance was 13.7${\pm}$1.0\% and 4.1${\pm}$0.7\% in the energy ranges of 5--10 keV$_{\rm ee}$ and 10--15 keV$_{\rm ee}$, respectively.
△ Less
Submitted 24 December, 2018; v1 submitted 16 September, 2018;
originally announced September 2018.
-
Search for sub-GeV dark matter by annual modulation using XMASS-I detector
Authors:
M. Kobayashi,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
T. Suzuki,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki,
B. D. Xu,
K. Miuchi
, et al. (11 additional authors not shown)
Abstract:
A search for dark matter (DM) with mass in the sub-GeV region (0.32-1 GeV) was conducted by looking for an annual modulation signal in XMASS, a single-phase liquid xenon detector. Inelastic nuclear scattering accompanied by bremsstrahlung emission was used to search down to an electron equivalent energy of 1 keV. The data used had a live time of 2.8 years (3.5 years in calendar time), resulting in…
▽ More
A search for dark matter (DM) with mass in the sub-GeV region (0.32-1 GeV) was conducted by looking for an annual modulation signal in XMASS, a single-phase liquid xenon detector. Inelastic nuclear scattering accompanied by bremsstrahlung emission was used to search down to an electron equivalent energy of 1 keV. The data used had a live time of 2.8 years (3.5 years in calendar time), resulting in a total exposure of 2.38 ton-years. No significant modulation signal was observed and 90% confidence level upper limits of $1.6 \times 10^{-33}$ cm$^2$ at 0.5 GeV was set for the DM-nucleon cross section. This is the first experimental result of a search for DM mediated by the bremsstrahlung effect. In addition, a search for DM with mass in the multi-GeV region (4-20 GeV) was conducted with a lower energy threshold than previous analysis of XMASS. Elastic nuclear scattering was used to search down to a nuclear recoil equivalent energy of 2.3 keV, and upper limits of 2.9 $\times$10$^{-42}$ cm$^2$ at 8 GeV was obtained.
△ Less
Submitted 22 December, 2018; v1 submitted 19 August, 2018;
originally announced August 2018.
-
Development of low radioactivity photomultiplier tubes for the XMASS-I detector
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
XMASS-I is a single-phase liquid xenon detector whose purpose is direct detection of dark matter. To achieve the low background requirements necessary in the detector, a new model of photomultiplier tubes (PMTs), R10789, with a hexagonal window was developed based on the R8778 PMT used in the XMASS prototype detector. We screened the numerous component materials for their radioactivity. During dev…
▽ More
XMASS-I is a single-phase liquid xenon detector whose purpose is direct detection of dark matter. To achieve the low background requirements necessary in the detector, a new model of photomultiplier tubes (PMTs), R10789, with a hexagonal window was developed based on the R8778 PMT used in the XMASS prototype detector. We screened the numerous component materials for their radioactivity. During development, the largest contributions to the reduction of radioactivity came from the stem and the dynode support. The glass stem was exchanged to the Kovar alloy one and the ceramic support were changed to the quartz one. R10789 is the first model of Hamamatsu Photonics K. K. that adopted these materials for low background purposes and provided a groundbreaking step for further reductions of radioactivity in PMTs. Measurements with germanium detectors showed 1.2$\pm$0.3 mBq/PMT of $^{226}$Ra, less than 0.78 mBq/PMT of $^{228}$Ra, 9.1$\pm$2.2 mBq/PMT of $^{40}$K, and 2.8$\pm$0.2 mBq/PMT of $^{60}$Co. In this paper, the radioactive details of the developed R10789 are described together with our screening methods and the components of the PMT.
△ Less
Submitted 29 January, 2019; v1 submitted 10 August, 2018;
originally announced August 2018.
-
Development of the measurement for radium using germanium detector with molecular recognition resin
Authors:
S. Ito,
K. Ichimura,
Y. Takaku,
K. Abe,
M. Ikeda,
Y. Kishimoto
Abstract:
High-purity germanium (HPGe) detectors are widely used for the measurement of the low concentrated radioactivities. For the Super-Kamiokande-Gadolinium project, the concentration of radium in Gd$_2$(SO$_4$)$_3{\cdot}$8H$_2$O is determined by using HPGe detectors. The amount of the sample is generally limited by the size of the sample space of a HPGe detector. This leads the limitation of the detec…
▽ More
High-purity germanium (HPGe) detectors are widely used for the measurement of the low concentrated radioactivities. For the Super-Kamiokande-Gadolinium project, the concentration of radium in Gd$_2$(SO$_4$)$_3{\cdot}$8H$_2$O is determined by using HPGe detectors. The amount of the sample is generally limited by the size of the sample space of a HPGe detector. This leads the limitation of the detector efficiency. A new method of chemical extraction using the molecular recognition resin was developed to minimize this problem. Using the developed method, radium could be extracted from Gd$_2$(SO$_4$)$_3{\cdot}$8H$_2$O and concentrated to smaller amount of the resin at a recovery rate of 81$\pm$4\%, which was estimated by using barium as a recovery monitor. This made it possible to set the sample closer to an HPGe crystal and reduce self screening effect, resulting in increasing the detection efficiency of an HPGe detector. The developed method is reported on this letter.
△ Less
Submitted 9 August, 2018;
originally announced August 2018.
-
Search for dark matter in the form of hidden photons and axion-like particles in the XMASS detector
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
T. Suzuki,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki
, et al. (13 additional authors not shown)
Abstract:
Hidden photons and axion-like particles are candidates for cold dark matter if they were produced non-thermally in the early universe. We conducted a search for both of these bosons using 800 live-days of data from the XMASS detector with 327 kg of liquid xenon in the fiducial volume. No significant signal was observed, and thus we set constraints on the $α' / α$ parameter related to kinetic mixin…
▽ More
Hidden photons and axion-like particles are candidates for cold dark matter if they were produced non-thermally in the early universe. We conducted a search for both of these bosons using 800 live-days of data from the XMASS detector with 327 kg of liquid xenon in the fiducial volume. No significant signal was observed, and thus we set constraints on the $α' / α$ parameter related to kinetic mixing of hidden photons and the coupling constant $g_{Ae}$ of axion-like particles in the mass range from 40 to 120 keV/$c^2$, resulting in $α' / α< 6 \times 10^{-26}$ and $g_{Ae} < 4 \times 10^{-13}$. These limits are the most stringent derived from both direct and indirect searches to date.
△ Less
Submitted 18 November, 2018; v1 submitted 23 July, 2018;
originally announced July 2018.
-
Hyper-Kamiokande Design Report
Authors:
Hyper-Kamiokande Proto-Collaboration,
:,
K. Abe,
Ke. Abe,
H. Aihara,
A. Aimi,
R. Akutsu,
C. Andreopoulos,
I. Anghel,
L. H. V. Anthony,
M. Antonova,
Y. Ashida,
V. Aushev,
M. Barbi,
G. J. Barker,
G. Barr,
P. Beltrame,
V. Berardi,
M. Bergevin,
S. Berkman,
L. Berns,
T. Berry,
S. Bhadra,
D. Bravo-Berguño,
F. d. M. Blaszczyk
, et al. (291 additional authors not shown)
Abstract:
On the strength of a double Nobel prize winning experiment (Super)Kamiokande and an extremely successful long baseline neutrino programme, the third generation Water Cherenkov detector, Hyper-Kamiokande, is being developed by an international collaboration as a leading worldwide experiment based in Japan. The Hyper-Kamiokande detector will be hosted in the Tochibora mine, about 295 km away from th…
▽ More
On the strength of a double Nobel prize winning experiment (Super)Kamiokande and an extremely successful long baseline neutrino programme, the third generation Water Cherenkov detector, Hyper-Kamiokande, is being developed by an international collaboration as a leading worldwide experiment based in Japan. The Hyper-Kamiokande detector will be hosted in the Tochibora mine, about 295 km away from the J-PARC proton accelerator research complex in Tokai, Japan. The currently existing accelerator will be steadily upgraded to reach a MW beam by the start of the experiment. A suite of near detectors will be vital to constrain the beam for neutrino oscillation measurements. A new cavern will be excavated at the Tochibora mine to host the detector. The experiment will be the largest underground water Cherenkov detector in the world and will be instrumented with new technology photosensors, faster and with higher quantum efficiency than the ones in Super-Kamiokande. The science that will be developed will be able to shape the future theoretical framework and generations of experiments. Hyper-Kamiokande will be able to measure with the highest precision the leptonic CP violation that could explain the baryon asymmetry in the Universe. The experiment also has a demonstrated excellent capability to search for proton decay, providing a significant improvement in discovery sensitivity over current searches for the proton lifetime. The atmospheric neutrinos will allow to determine the neutrino mass ordering and, together with the beam, able to precisely test the three-flavour neutrino oscillation paradigm and search for new phenomena. A strong astrophysical programme will be carried out at the experiment that will detect supernova neutrinos and will measure precisely solar neutrino oscillation.
△ Less
Submitted 28 November, 2018; v1 submitted 9 May, 2018;
originally announced May 2018.
-
A direct dark matter search in XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
A search for dark matter using an underground single-phase liquid xenon detector was conducted at the Kamioka Observatory in Japan, particularly for Weakly Interacting Massive Particles (WIMPs). We have used 705.9 live days of data in a fiducial volume containing 97 kg of liquid xenon at the center of the detector. The event rate in the fiducial volume after the data reduction was…
▽ More
A search for dark matter using an underground single-phase liquid xenon detector was conducted at the Kamioka Observatory in Japan, particularly for Weakly Interacting Massive Particles (WIMPs). We have used 705.9 live days of data in a fiducial volume containing 97 kg of liquid xenon at the center of the detector. The event rate in the fiducial volume after the data reduction was ${\rm (4.2 \pm 0.2) \times 10^{-3} \, day^{-1}kg^{-1} keV_{ee}^{-1}}$ at ${\rm 5 \, keV_{ee}}$, with a signal efficiency of ${\rm 20\%}$. All the remaining events are consistent with our background evaluation, mostly of the "mis-reconstructed events" originated from $^{210}$Pb in the copper plates lining the detector's inner surface. The obtained upper limit on a spin-independent WIMP-nucleon cross section was ${\rm 2.2 \times 10^{-44} \, cm^{2}}$ for a WIMP mass of ${\rm 60 \, GeV/c^{2}}$ at the $90\%$ confidence level, which was the most stringent limit among results from single-phase liquid xenon detectors.
△ Less
Submitted 25 December, 2018; v1 submitted 6 April, 2018;
originally announced April 2018.
-
Improved search for two-neutrino double electron capture on $^{124}$Xe and $^{126}$Xe using particle identification in XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
We conducted an improved search for the simultaneous capture of two $K$-shell electrons on the $^{124}$Xe and $^{126}$Xe nuclei with emission of two neutrinos using 800.0 days of data from the XMASS-I detector. A novel method to discriminate $γ$-ray/$X$-ray or double electron capture signals from $β$-ray background using scintillation time profiles was developed for this search. No significant sig…
▽ More
We conducted an improved search for the simultaneous capture of two $K$-shell electrons on the $^{124}$Xe and $^{126}$Xe nuclei with emission of two neutrinos using 800.0 days of data from the XMASS-I detector. A novel method to discriminate $γ$-ray/$X$-ray or double electron capture signals from $β$-ray background using scintillation time profiles was developed for this search. No significant signal was found when fitting the observed energy spectra with the expected signal and background. Therefore, we set the most stringent lower limits on the half-lives at $2.1 \times 10^{22}$ and $1.9 \times 10^{22}$ years for $^{124}$Xe and $^{126}$Xe, respectively, with 90% confidence level. These limits improve upon previously reported values by a factor of 4.5.
△ Less
Submitted 16 April, 2018; v1 submitted 10 January, 2018;
originally announced January 2018.
-
Determination of Trace Levels of Uranium and Thorium in High Purity Gadolinium Sulfate Using ICP-MS with Solid-Phase Chromatographic Extraction Resin
Authors:
S. Ito,
Y. Takaku,
M. Ikeda,
Y. Kishimoto
Abstract:
The new Super-Kamiokande-Gadolinium (SK-Gd) project is an upgrade of the Super-Kamiokande (SK) detector. In the SK-Gd project, 0.2\% Gd$_2$(SO$_4$)$_3$ is loaded into the 50 kton water tank of the SK. One of the main purposes of the project is to discover Supernova Relic Neutrinos. Neutrino measurements and proton decay searches will also be performed in the SK-Gd. In order to measure solar neutri…
▽ More
The new Super-Kamiokande-Gadolinium (SK-Gd) project is an upgrade of the Super-Kamiokande (SK) detector. In the SK-Gd project, 0.2\% Gd$_2$(SO$_4$)$_3$ is loaded into the 50 kton water tank of the SK. One of the main purposes of the project is to discover Supernova Relic Neutrinos. Neutrino measurements and proton decay searches will also be performed in the SK-Gd. In order to measure solar neutrinos with a low energy threshold of $\sim$3.5 MeV in the SK-Gd, the main radioactive contaminations, $^{238}$U and $^{232}$Th, in Gd$_2$(SO$_4$)$_3{\cdot}$8H$_2$O, should be minimized before loading. Our maximum levels for U and Th are 5 mBq (U)/kg (Gd$_2$(SO$_4$)$_3{\cdot}$8H$_2$O) and 0.05 mBq (Th)/kg (Gd$_2$(SO$_4$)$_3{\cdot}$8H$_2$O).
In order to measure such low concentrations of U and Th in Gd$_2$(SO$_4$)$_3{\cdot}$8H$_2$O, we developed the solid-phase extraction technique. Using this method, about 90\% or more U and Th could be efficiently extracted while Gd was reduced by a factor of about $10^{4}$. This allowed these radioactivity contaminations to be measured precisely as 0.04 mBq/kg (Gd$_2$(SO$_4$)$_3{\cdot}$8H$_2$O) for U and 0.01 mBq/kg (Gd$_2$(SO$_4$)$_3{\cdot}$8H$_2$O) for Th. We measured three pure Gd$_2$(SO$_4$)$_3{\cdot}$8H$_2$O samples using this method and estimated that the purest one contained $<0.04$ mBq (U)/kg (Gd$_2$(SO$_4$)$_3{\cdot}$8H$_2$O) and 0.06 $\pm$ 0.01 mBq (Th)/kg (Gd$_2$(SO$_4$)$_3{\cdot}$8H$_2$O) by ICP-MS.
△ Less
Submitted 6 October, 2017; v1 submitted 11 September, 2017;
originally announced September 2017.
-
Search for solar Kaluza-Klein axion by annual modulation with the XMASS-I detector
Authors:
XMASS Collaboration,
N. Oka,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda
, et al. (17 additional authors not shown)
Abstract:
In theories with the large extra dimensions beyond the standard 4-dimensional spacetime, axions could propagate in such extra dimensions, and acquire Kaluza-Klein (KK) excitations. These KK axions are produced in the Sun and could solve unexplained heating of the solar corona. While most of the solar KK axions escape from the solar system, a small fraction is gravitationally trapped in orbits arou…
▽ More
In theories with the large extra dimensions beyond the standard 4-dimensional spacetime, axions could propagate in such extra dimensions, and acquire Kaluza-Klein (KK) excitations. These KK axions are produced in the Sun and could solve unexplained heating of the solar corona. While most of the solar KK axions escape from the solar system, a small fraction is gravitationally trapped in orbits around the Sun. They would decay into two photons inside a terrestrial detector. The event rate is expected to modulate annually depending on the distance from the Sun. We have searched for the annual modulation signature using $832\times 359$ kg$\cdot$days of XMASS-I data. No significant event rate modulation is found, and hence we set the first experimental constraint on the KK axion-photon coupling of $4.8 \times 10^{-12}\, \mathrm{GeV}^{-1}$ at 90% confidence level for a KK axion number density of $\bar{n}_\mathrm{a} = 4.07 \times 10^{13}\, \mathrm{m}^{-3}$, the total number of extra dimensions $n = 2$, and the number of extra dimensions $δ= 2$ that axions can propagate in.
△ Less
Submitted 15 November, 2017; v1 submitted 19 July, 2017;
originally announced July 2017.
-
Identification of $^{210}$Pb and $^{210}$Po in the bulk of copper samples with a low-background alpha particle counter
Authors:
XMASS collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
We established a method to assay $^{210}$Pb and $^{210}$Po contaminations in the bulk of copper samples using a low-background alpha particle counter. The achieved sensitivity for the $^{210}$Pb and $^{210}$Po contaminations reaches a few mBq/kg. Due to this high sensitivity, the $^{210}$Pb and $^{210}$Po contaminations in oxygen free copper bulk were identified and measured for the first time. Th…
▽ More
We established a method to assay $^{210}$Pb and $^{210}$Po contaminations in the bulk of copper samples using a low-background alpha particle counter. The achieved sensitivity for the $^{210}$Pb and $^{210}$Po contaminations reaches a few mBq/kg. Due to this high sensitivity, the $^{210}$Pb and $^{210}$Po contaminations in oxygen free copper bulk were identified and measured for the first time. The $^{210}$Pb contaminations of our oxygen free copper samples were 17-40 mBq/kg. Based on our investigation of copper samples in each production step, the $^{210}$Pb in oxygen free copper was understood to be a small residual of an electrolysis process. This method to measure bulk contaminations of $^{210}$Pb and $^{210}$Po could be applied to other materials.
△ Less
Submitted 9 January, 2018; v1 submitted 20 July, 2017;
originally announced July 2017.
-
Statistical description of turbulent transport for flux driven toroidal plasmas
Authors:
J. Anderson,
K. Imadera,
Y. Kishimoto,
J. Q. Li,
H. Nordman
Abstract:
A novel methodology to analyze non-Gaussian probability distribution functions (PDFs) of intermittent turbulent transport in global full-f gyrokinetic simulations is presented. In this work, the Auto-Regressive Integrated Moving Average (ARIMA) model is applied to time series data of intermittent turbulent heat transport to separate noise and oscillatory trends, allowing for the extraction of non-…
▽ More
A novel methodology to analyze non-Gaussian probability distribution functions (PDFs) of intermittent turbulent transport in global full-f gyrokinetic simulations is presented. In this work, the Auto-Regressive Integrated Moving Average (ARIMA) model is applied to time series data of intermittent turbulent heat transport to separate noise and oscillatory trends, allowing for the extraction of non-Gaussian features of the PDFs. It was shown that non-Gaussian tails of the PDFs from first principles based gyrokinetic simulations agree with an analytical estimation based on a two fluid model.
△ Less
Submitted 9 June, 2017;
originally announced June 2017.
-
Physics Potentials with the Second Hyper-Kamiokande Detector in Korea
Authors:
Hyper-Kamiokande proto-collaboration,
:,
K. Abe,
Ke. Abe,
S. H. Ahn,
H. Aihara,
A. Aimi,
R. Akutsu,
C. Andreopoulos,
I. Anghel,
L. H. V. Anthony,
M. Antonova,
Y. Ashida,
V. Aushev,
M. Barbi,
G. J. Barker,
G. Barr,
P. Beltrame,
V. Berardi,
M. Bergevin,
S. Berkman,
L. Berns,
T. Berry,
S. Bhadra,
D. Bravo-Bergu no
, et al. (331 additional authors not shown)
Abstract:
Hyper-Kamiokande consists of two identical water-Cherenkov detectors of total 520~kt with the first one in Japan at 295~km from the J-PARC neutrino beam with 2.5$^{\textrm{o}}$ Off-Axis Angles (OAAs), and the second one possibly in Korea in a later stage. Having the second detector in Korea would benefit almost all areas of neutrino oscillation physics mainly due to longer baselines. There are sev…
▽ More
Hyper-Kamiokande consists of two identical water-Cherenkov detectors of total 520~kt with the first one in Japan at 295~km from the J-PARC neutrino beam with 2.5$^{\textrm{o}}$ Off-Axis Angles (OAAs), and the second one possibly in Korea in a later stage. Having the second detector in Korea would benefit almost all areas of neutrino oscillation physics mainly due to longer baselines. There are several candidate sites in Korea with baselines of 1,000$\sim$1,300~km and OAAs of 1$^{\textrm{o}}$$\sim$3$^{\textrm{o}}$. We conducted sensitivity studies on neutrino oscillation physics for a second detector, either in Japan (JD $\times$ 2) or Korea (JD + KD) and compared the results with a single detector in Japan. Leptonic CP violation sensitivity is improved especially when the CP is non-maximally violated. The larger matter effect at Korean candidate sites significantly enhances sensitivities to non-standard interactions of neutrinos and mass ordering determination. Current studies indicate the best sensitivity is obtained at Mt. Bisul (1,088~km baseline, $1.3^\circ$ OAA). Thanks to a larger (1,000~m) overburden than the first detector site, clear improvements to sensitivities for solar and supernova relic neutrino searches are expected.
△ Less
Submitted 26 March, 2018; v1 submitted 18 November, 2016;
originally announced November 2016.
-
Solar Neutrino Measurements in Super-Kamiokande-IV
Authors:
Super-Kamiokande Collaboration,
:,
K. Abe,
Y. Haga,
Y. Hayato,
M. Ikeda,
K. Iyogi,
J. Kameda,
Y. Kishimoto,
Ll. Marti,
M. Miura,
S. Moriyama,
M. Nakahata,
T. Nakajima,
S. Nakayama,
A. Orii,
H. Sekiya,
M. Shiozawa,
Y. Sonoda,
A. Takeda,
H. Tanaka,
Y. Takenaga,
S. Tasaka,
T. Tomura,
K. Ueno
, et al. (146 additional authors not shown)
Abstract:
Upgraded electronics, improved water system dynamics, better calibration and analysis techniques allowed Super-Kamiokande-IV to clearly observe very low-energy 8B solar neutrino interactions, with recoil electron kinetic energies as low as 3.49 MeV. Super-Kamiokande-IV data-taking began in September of 2008; this paper includes data until February 2014, a total livetime of 1664 days. The measured…
▽ More
Upgraded electronics, improved water system dynamics, better calibration and analysis techniques allowed Super-Kamiokande-IV to clearly observe very low-energy 8B solar neutrino interactions, with recoil electron kinetic energies as low as 3.49 MeV. Super-Kamiokande-IV data-taking began in September of 2008; this paper includes data until February 2014, a total livetime of 1664 days. The measured solar neutrino flux is (2.308+-0.020(stat.) + 0.039-0.040(syst.)) x 106/(cm2sec) assuming no oscillations. The observed recoil electron energy spectrum is consistent with no distortions due to neutrino oscillations. An extended maximum likelihood fit to the amplitude of the expected solar zenith angle variation of the neutrino-electron elastic scattering rate in SK-IV results in a day/night asymmetry of (-3.6+-1.6(stat.)+-0.6(syst.))%. The SK-IV solar neutrino data determine the solar mixing angle as sin2 theta_12 = 0.327+0.026-0.031, all SK solar data (SK-I, SK-II, SK III and SKIV) measures this angle to be sin2 theta_12 = 0.334+0.027-0.023, the determined mass-squared splitting is Delta m2_21 = 4.8+1.5-0.8 x10-5 eV2.
△ Less
Submitted 23 June, 2016;
originally announced June 2016.
-
A measurement of the time profile of scintillation induced by low energy gamma-rays in liquid xenon with the XMASS-I detector
Authors:
XMASS Collaboration,
H. Takiya,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
R. Kegasa,
K. Kobayashi,
K. Masuda,
K. Fushimi
, et al. (15 additional authors not shown)
Abstract:
We report the measurement of the emission time profile of scintillation from gamma-ray induced events in the XMASS-I 832 kg liquid xenon scintillation detector. Decay time constant was derived from a comparison of scintillation photon timing distributions between the observed data and simulated samples in order to take into account optical processes such as absorption and scattering in liquid xeno…
▽ More
We report the measurement of the emission time profile of scintillation from gamma-ray induced events in the XMASS-I 832 kg liquid xenon scintillation detector. Decay time constant was derived from a comparison of scintillation photon timing distributions between the observed data and simulated samples in order to take into account optical processes such as absorption and scattering in liquid xenon. Calibration data of radioactive sources, $^{55}$Fe, $^{241}$Am, and $^{57}$Co were used to obtain the decay time constant. Assuming two decay components, $τ_1$ and $τ_2$, the decay time constant $τ_2$ increased from 27.9 ns to 37.0 ns as the gamma-ray energy increased from 5.9 keV to 122 keV. The accuracy of the measurement was better than 1.5 ns at all energy levels. A fast decay component with $τ_1 \sim 2$ ns was necessary to reproduce data. Energy dependencies of $τ_2$ and the fraction of the fast decay component were studied as a function of the kinetic energy of electrons induced by gamma-rays. The obtained data almost reproduced previously reported results and extended them to the lower energy region relevant to direct dark matter searches.
△ Less
Submitted 18 August, 2016; v1 submitted 6 April, 2016;
originally announced April 2016.
-
Direct dark matter search by annual modulation in XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
H. Sekiya,
O. Takachio,
A. Takeda,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
S. Tasaka,
K. Fushimi,
J. Liu,
K. Martens,
Y. Suzuki,
B. D. Xu,
R. Fujita
, et al. (17 additional authors not shown)
Abstract:
A search for dark matter was conducted by looking for an annual modulation signal due to the Earth's rotation around the Sun using XMASS, a single phase liquid xenon detector. The data used for this analysis was 359.2 live days times 832 kg of exposure accumulated between November 2013 and March 2015. When we assume Weakly Interacting Massive Particle (WIMP) dark matter elastically scattering on t…
▽ More
A search for dark matter was conducted by looking for an annual modulation signal due to the Earth's rotation around the Sun using XMASS, a single phase liquid xenon detector. The data used for this analysis was 359.2 live days times 832 kg of exposure accumulated between November 2013 and March 2015. When we assume Weakly Interacting Massive Particle (WIMP) dark matter elastically scattering on the target nuclei, the exclusion upper limit of the WIMP-nucleon cross section 4.3$\times$10$^{-41}$cm$^2$ at 8 GeV/c$^2$ was obtained and we exclude almost all the DAMA/LIBRA allowed region in the 6 to 16 GeV/c$^2$ range at $\sim$10$^{-40}$cm$^2$. The result of a simple modulation analysis, without assuming any specific dark matter model but including electron/$γ$ events, showed a slight negative amplitude. The $p$-values obtained with two independent analyses are 0.014 and 0.068 for null hypothesis, respectively. we obtained 90\% C.L. upper bounds that can be used to test various models. This is the first extensive annual modulation search probing this region with an exposure comparable to DAMA/LIBRA.
△ Less
Submitted 25 May, 2016; v1 submitted 15 November, 2015;
originally announced November 2015.
-
Measurements of the atmospheric neutrino flux by Super-Kamiokande: energy spectra, geomagnetic effects, and solar modulation
Authors:
E. Richard,
K. Okumura,
K. Abe,
Y. Haga,
Y. Hayato,
M. Ikeda,
K. Iyogi,
J. Kameda,
Y. Kishimoto,
M. Miura,
S. Moriyama,
M. Nakahata,
T. Nakajima,
Y. Nakano,
S. Nakayama,
A. Orii,
H. Sekiya,
M. Shiozawa,
A. Takeda,
H. Tanaka,
T. Tomura,
R. A. Wendell,
R. Akutsu,
T. Irvine,
T. Kajita
, et al. (104 additional authors not shown)
Abstract:
A comprehensive study on the atmospheric neutrino flux in the energy region from sub-GeV up to several TeV using the Super-Kamiokande water Cherenkov detector is presented in this paper. The energy and azimuthal spectra of the atmospheric $ν_e+{\barν}_e$ and $ν_μ+{\barν}_μ$ fluxes are measured. The energy spectra are obtained using an iterative unfolding method by combining various event topologie…
▽ More
A comprehensive study on the atmospheric neutrino flux in the energy region from sub-GeV up to several TeV using the Super-Kamiokande water Cherenkov detector is presented in this paper. The energy and azimuthal spectra of the atmospheric $ν_e+{\barν}_e$ and $ν_μ+{\barν}_μ$ fluxes are measured. The energy spectra are obtained using an iterative unfolding method by combining various event topologies with differing energy responses. The azimuthal spectra depending on energy and zenith angle, and their modulation by geomagnetic effects, are also studied. A predicted east-west asymmetry is observed in both the $ν_e$ and $ν_μ$ samples at 8.0 σ and 6.0 σ significance, respectively, and an indication that the asymmetry dipole angle changes depending on the zenith angle was seen at the 2.2 σ level. The measured energy and azimuthal spectra are consistent with the current flux models within the estimated systematic uncertainties. A study of the long-term correlation between the atmospheric neutrino flux and the solar magnetic activity cycle is also performed, and a weak indication of a correlation was seen at the 1.1 σ level, using SK I-IV data spanning a 20 year period. For particularly strong solar activity periods known as Forbush decreases, no theoretical prediction is available, but a deviation below the typical neutrino event rate is seen at the 2.4 σ level.
△ Less
Submitted 6 September, 2016; v1 submitted 27 October, 2015;
originally announced October 2015.
-
Search for two-neutrino double electron capture on $^{124}$Xe with the XMASS-I detector
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
K. Nakagawa,
M. Nakahata,
T. Norita,
H. Ogawa,
H. Sekiya,
O. Takachio,
A. Takeda,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
S. Tasaka,
J. Liu,
K. Martens,
Y. Suzuki,
R. Fujita,
K. Hosokawa
, et al. (19 additional authors not shown)
Abstract:
Double electron capture is a rare nuclear decay process in which two orbital electrons are captured simultaneously in the same nucleus. Measurement of its two-neutrino mode would provide a new reference for the calculation of nuclear matrix elements whereas observation of its neutrinoless mode would demonstrate lepton number violation. A search for two-neutrino double electron capture on $^{124}$X…
▽ More
Double electron capture is a rare nuclear decay process in which two orbital electrons are captured simultaneously in the same nucleus. Measurement of its two-neutrino mode would provide a new reference for the calculation of nuclear matrix elements whereas observation of its neutrinoless mode would demonstrate lepton number violation. A search for two-neutrino double electron capture on $^{124}$Xe is performed using 165.9 days of data collected with the XMASS-I liquid xenon detector. No significant excess above background was observed and we set a lower limit on the half-life as $4.7 \times 10^{21}$ years at 90% confidence level. The obtained limit has ruled out parts of some theoretical expectations. We obtain a lower limit on the $^{126}$Xe two-neutrino double electron capture half-life of $4.3 \times 10^{21}$ years at 90% confidence level as well.
△ Less
Submitted 25 May, 2016; v1 submitted 2 October, 2015;
originally announced October 2015.
-
A Long Baseline Neutrino Oscillation Experiment Using J-PARC Neutrino Beam and Hyper-Kamiokande
Authors:
Hyper-Kamiokande Working Group,
:,
K. Abe,
H. Aihara,
C. Andreopoulos,
I. Anghel,
A. Ariga,
T. Ariga,
R. Asfandiyarov,
M. Askins,
J. J. Back,
P. Ballett,
M. Barbi,
G. J. Barker,
G. Barr,
F. Bay,
P. Beltrame,
V. Berardi,
M. Bergevin,
S. Berkman,
T. Berry,
S. Bhadra,
F. d. M. Blaszczyk,
A. Blondel,
S. Bolognesi
, et al. (224 additional authors not shown)
Abstract:
Hyper-Kamiokande will be a next generation underground water Cherenkov detector with a total (fiducial) mass of 0.99 (0.56) million metric tons, approximately 20 (25) times larger than that of Super-Kamiokande. One of the main goals of Hyper-Kamiokande is the study of $CP$ asymmetry in the lepton sector using accelerator neutrino and anti-neutrino beams.
In this document, the physics potential o…
▽ More
Hyper-Kamiokande will be a next generation underground water Cherenkov detector with a total (fiducial) mass of 0.99 (0.56) million metric tons, approximately 20 (25) times larger than that of Super-Kamiokande. One of the main goals of Hyper-Kamiokande is the study of $CP$ asymmetry in the lepton sector using accelerator neutrino and anti-neutrino beams.
In this document, the physics potential of a long baseline neutrino experiment using the Hyper-Kamiokande detector and a neutrino beam from the J-PARC proton synchrotron is presented. The analysis has been updated from the previous Letter of Intent [K. Abe et al., arXiv:1109.3262 [hep-ex]], based on the experience gained from the ongoing T2K experiment. With a total exposure of 7.5 MW $\times$ 10$^7$ sec integrated proton beam power (corresponding to $1.56\times10^{22}$ protons on target with a 30 GeV proton beam) to a $2.5$-degree off-axis neutrino beam produced by the J-PARC proton synchrotron, it is expected that the $CP$ phase $δ_{CP}$ can be determined to better than 19 degrees for all possible values of $δ_{CP}$, and $CP$ violation can be established with a statistical significance of more than $3\,σ$ ($5\,σ$) for $76%$ ($58%$) of the $δ_{CP}$ parameter space.
△ Less
Submitted 18 January, 2015; v1 submitted 15 December, 2014;
originally announced December 2014.
-
A compact ultra-clean system for deploying radioactive sources inside the KamLAND detector
Authors:
T. I. Banks,
S. J. Freedman,
J. Wallig,
N. Ybarrolaza,
A. Gando,
Y. Gando,
H. Ikeda,
K. Inoue,
Y. Kishimoto,
M. Koga,
T. Mitsui,
K. Nakamura,
I. Shimizu,
J. Shirai,
A. Suzuki,
Y. Takemoto,
K. Tamae,
K. Ueshima,
H. Watanabe,
B. D. Xu,
H. Yoshida,
S. Yoshida,
A. Kozlov,
C. Grant,
G. Keefer
, et al. (32 additional authors not shown)
Abstract:
We describe a compact, ultra-clean device used to deploy radioactive sources along the vertical axis of the KamLAND liquid-scintillator neutrino detector for purposes of calibration. The device worked by paying out and reeling in precise lengths of a hanging, small-gauge wire rope (cable); an assortment of interchangeable radioactive sources could be attached to a weight at the end of the cable. A…
▽ More
We describe a compact, ultra-clean device used to deploy radioactive sources along the vertical axis of the KamLAND liquid-scintillator neutrino detector for purposes of calibration. The device worked by paying out and reeling in precise lengths of a hanging, small-gauge wire rope (cable); an assortment of interchangeable radioactive sources could be attached to a weight at the end of the cable. All components exposed to the radiopure liquid scintillator were made of chemically compatible UHV-cleaned materials, primarily stainless steel, in order to avoid contaminating or degrading the scintillator. To prevent radon intrusion, the apparatus was enclosed in a hermetically sealed housing inside a glove box, and both volumes were regularly flushed with purified nitrogen gas. An infrared camera attached to the side of the housing permitted real-time visual monitoring of the cable's motion, and the system was controlled via a graphical user interface.
△ Less
Submitted 11 February, 2015; v1 submitted 1 July, 2014;
originally announced July 2014.
-
Search for bosonic superweakly interacting massive dark matter particles with the XMASS-I detector
Authors:
K. Abe,
K. Hieda,
K. Hiraide,
S. Hirano,
Y. Kishimoto,
K. Ichimura,
K. Kobayashi,
S. Moriyama,
K. Nakagawa,
M. Nakahata,
H. Ogawa,
N. Oka,
H. Sekiya,
A. Shinozaki,
Y. Suzuki,
A. Takeda,
O. Takachio,
D. Umemoto,
M. Yamashita,
B. S. Yang,
S. Tasaka,
J. Liu,
K. Martens,
K. Hosokawa,
K. Miuchi
, et al. (20 additional authors not shown)
Abstract:
Bosonic superweakly interacting massive particles (super-WIMPs) are a candidate for warm dark matter. With the absorption of such a boson by a xenon atom these dark matter candidates would deposit an energy equivalent to their rest mass in the detector. This is the first direct detection experiment exploring the vector super-WIMPs in the mass range between 40 and 120 keV. Using 165.9 days of data…
▽ More
Bosonic superweakly interacting massive particles (super-WIMPs) are a candidate for warm dark matter. With the absorption of such a boson by a xenon atom these dark matter candidates would deposit an energy equivalent to their rest mass in the detector. This is the first direct detection experiment exploring the vector super-WIMPs in the mass range between 40 and 120 keV. Using 165.9 days of data no significant excess above background was observed in the fiducial mass of 41 kg. The present limit for the vector super-WIMPs excludes the possibility that such particles constitute all of dark matter. The absence of a signal also provides the most stringent direct constraint on the coupling constant of pseudoscalar super-WIMPs to electrons. The unprecedented sensitivity was achieved exploiting the low background at a level $10^{-4}$ kg$^{-1}$keV$_{ee}^{-1}$day$^{-1}$ in the detector.
△ Less
Submitted 21 August, 2014; v1 submitted 2 June, 2014;
originally announced June 2014.
-
Search for inelastic WIMP nucleus scattering on $^{129}$Xe in data from the XMASS-I experiment
Authors:
H. Uchida,
K. Abe,
K. Hieda,
K. Hiraide,
S. Hirano,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
S. Moriyama,
K. Nakagawa,
M. Nakahata,
H. Ogawa,
N. Oka,
H. Sekiya,
A. Shinozaki,
Y. Suzuki,
A. Takeda,
O. Takachio,
D. Umemoto,
M. Yamashita,
B. S. Yang,
S. Tasaka,
J. Liu,
K. Martens,
K. Hosokawa
, et al. (21 additional authors not shown)
Abstract:
A search for inelastic scattering of Weakly Interacting Massive Particles (WIMPs) on the isotope $^{129}$Xe was done in data taken with the single phase liquid xenon detector XMASS at the Kamioka Observatory. Using a restricted volume containing 41 kg of LXe at the very center of our detector we observed no significant excess of events in 165.9 days of data. Our background reduction allowed us to…
▽ More
A search for inelastic scattering of Weakly Interacting Massive Particles (WIMPs) on the isotope $^{129}$Xe was done in data taken with the single phase liquid xenon detector XMASS at the Kamioka Observatory. Using a restricted volume containing 41 kg of LXe at the very center of our detector we observed no significant excess of events in 165.9 days of data. Our background reduction allowed us to derive our limits without explicitly subtracting the remaining events which are compatible with background expectations and derive for e.g. a 50 GeV WIMP an upper limit for its inelastic cross section on $^{129}$Xe nuclei of 3.2 pb at the 90% confidence level.
△ Less
Submitted 29 April, 2014; v1 submitted 19 January, 2014;
originally announced January 2014.
-
Laboratory Studies on the Removal of Radon-Born Lead from KamLAND's Organic Liquid Scintillator
Authors:
G. Keefer,
C. Grant,
A. Piepke,
T. Ebihara,
H. Ikeda,
Y. Kishimoto,
Y. Kibe,
Y. Koseki,
M. Ogawa,
J. Shirai,
S. Takeuchi,
C. Mauger,
C. Zhang,
G. Schweitzer,
B. E. Berger,
S. Dazeley,
M. P. Decowski,
J. A. Detwiler,
Z. Djurcic,
D. A. Dwyer,
Y. Efremenko,
S. Enomoto,
S. J. Freedman,
B. K. Fujikawa,
K. Furuno
, et al. (43 additional authors not shown)
Abstract:
The removal of radioactivity from liquid scintillator has been studied in preparation of a low background phase of KamLAND. This paper describes the methods and techniques developed to measure and efficiently extract radon decay products from liquid scintillator. We report the radio-isotope reduction factors obtained when applying various extraction methods. During this study, distillation was ide…
▽ More
The removal of radioactivity from liquid scintillator has been studied in preparation of a low background phase of KamLAND. This paper describes the methods and techniques developed to measure and efficiently extract radon decay products from liquid scintillator. We report the radio-isotope reduction factors obtained when applying various extraction methods. During this study, distillation was identified as the most efficient method for removing radon daughters from liquid scintillator.
△ Less
Submitted 3 December, 2013;
originally announced December 2013.
-
Development of a 30 cm-cube Electron-Tracking Compton Camera for the SMILE-II Experiment
Authors:
Y. Mizumura,
T. Tanimori,
H. Kubo,
A. Takada,
J. D. Parker,
T. Mizumoto,
S. Sonoda,
D. Tomono,
T. Sawano,
K. Nakamura,
Y. Matsuoka,
S. Komura,
S. Nakamura,
M. Oda,
K. Miuchi,
S. Kabuki,
Y. Kishimoto,
S. Kurosawa,
S. Iwaki
Abstract:
To explore the sub-MeV/MeV gamma-ray window for astronomy, we have developed the Electron-Tracking Compton Camera (ETCC), and carried out the first performance test at room condition using several gamma-ray sources in the sub-MeV energy band. Using a simple track analysis for a quick first test of the performance, the gamma-ray imaging capability was demonstrated by clear images and 5.3 degrees of…
▽ More
To explore the sub-MeV/MeV gamma-ray window for astronomy, we have developed the Electron-Tracking Compton Camera (ETCC), and carried out the first performance test at room condition using several gamma-ray sources in the sub-MeV energy band. Using a simple track analysis for a quick first test of the performance, the gamma-ray imaging capability was demonstrated by clear images and 5.3 degrees of angular resolution measure (ARM) measured at 662 keV. As the greatest impact of this work, a gamma-ray detection efficiency on the order of $10^{-4}$ was achieved at the sub-MeV gamma-ray band, which is one order of magnitude higher than our previous experiment. This angular resolution and detection efficiency enables us to detect the Crab Nebula at the 5 sigma level with several hours observation at balloon altitude in middle latitude. Furthermore, good consistency of efficiencies between this performance test and simulation including only physical processes has a large importance; it means we achieve nearly 100% detection of Compton recoil electrons. Thus, our estimation of enhancements by upgrades of the detector is more dependable. We are planning to confirm the imaging capability of the ETCC by observation of celestial objects in the SMILE-II (Sub-MeV gamma ray Imaging Loaded-on-balloon Experiment II). The SMILE-II and following SMILE-III project will be an important key of sub-MeV/MeV gamma-ray astronomy.
△ Less
Submitted 7 February, 2014; v1 submitted 2 December, 2013;
originally announced December 2013.
-
Calibration of the Super-Kamiokande Detector
Authors:
K. Abe,
Y. Hayato,
T. Iida,
K. Iyogi,
J. Kameda,
Y. Kishimoto,
Y. Koshio,
Ll. Marti,
M. Miura,
S. Moriyama,
M. Nakahata,
Y. Nakano,
S. Nakayama,
Y. Obayashi,
H. Sekiya,
M. Shiozawa,
Y. Suzuki,
A. Takeda,
Y. Takenaga,
H. Tanaka,
T. Tomura,
K. Ueno,
R. A. Wendell,
T. Yokozawa,
T. J. Irvine
, et al. (108 additional authors not shown)
Abstract:
Procedures and results on hardware level detector calibration in Super-Kamiokande (SK) are presented in this paper. In particular, we report improvements made in our calibration methods for the experimental phase IV in which new readout electronics have been operating since 2008. The topics are separated into two parts. The first part describes the determination of constants needed to interpret th…
▽ More
Procedures and results on hardware level detector calibration in Super-Kamiokande (SK) are presented in this paper. In particular, we report improvements made in our calibration methods for the experimental phase IV in which new readout electronics have been operating since 2008. The topics are separated into two parts. The first part describes the determination of constants needed to interpret the digitized output of our electronics so that we can obtain physical numbers such as photon counts and their arrival times for each photomultiplier tube (PMT). In this context, we developed an in-situ procedure to determine high-voltage settings for PMTs in large detectors like SK, as well as a new method for measuring PMT quantum efficiency and gain in such a detector. The second part describes the modeling of the detector in our Monte Carlo simulation, including in particular the optical properties of its water target and their variability over time. Detailed studies on the water quality are also presented. As a result of this work, we achieved a precision sufficient for physics analysis over a wide energy range (from a few MeV to above a TeV). For example, the charge determination was understood at the 1% level, and the timing resolution was 2.1 nsec at the one-photoelectron charge level and 0.5 nsec at the 100-photoelectron charge level.
△ Less
Submitted 20 December, 2013; v1 submitted 29 June, 2013;
originally announced July 2013.
-
Development of a Time-resolved Neutron Imaging Detector Based on the μPIC Micro-Pixel Chamber
Authors:
Joseph D Parker,
Masahide Harada,
Kaori Hattori,
Satoru Iwaki,
Shigeto Kabuki,
Yuji Kishimoto,
Hidetoshi Kubo,
Shunsuke Kurosawa,
Yoshihiro Matsuoka,
Kentaro Miuchi,
Tetsuya Mizumoto,
Hironobu Nishimura,
Takayuki Oku,
Tatsuya Sawano,
Takenao Shinohara,
Jun-ichi Suzuki,
Atsushi Takada,
Toru Tanimori,
Kazuki Ueno,
Masahiro Ikeno,
Manobu Tanaka,
Tomohisa Uchida
Abstract:
We have developed a prototype time-resolved neutron imaging detector employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data acquisition system. Our detector system combines 100μm-level spatial and sub-μs time resolutions with a low gamma sensitivity of less than 10^-12 and high data rates, making it well suited for…
▽ More
We have developed a prototype time-resolved neutron imaging detector employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data acquisition system. Our detector system combines 100μm-level spatial and sub-μs time resolutions with a low gamma sensitivity of less than 10^-12 and high data rates, making it well suited for applications in neutron radiography at high-intensity, pulsed neutron sources. In the present paper, we introduce the detector system and present several test measurements performed at NOBORU (BL10), J-PARC to demonstrate the capabilities of our prototype. We also discuss future improvements to the spatial resolution and rate performance.
△ Less
Submitted 20 May, 2013;
originally announced May 2013.
-
Spatial resolution of a μPIC-based neutron imaging detector
Authors:
Joseph D. Parker,
Masahide Harada,
Kaori Hattori,
Satoru Iwaki,
Shigeto Kabuki,
Yuji Kishimoto,
Hidetoshi Kubo,
Shunsuke Kurosawa,
Yoshihiro Matsuoka,
Kentaro Miuchi,
Tetsuya Mizumoto,
Hironobu Nishimura,
Takayuki Oku,
Tatsuya Sawano,
Takenao Shinohara,
Jun-ichi Suzuki,
Atsushi Takada,
Toru Tanimori,
Kazuki Ueno
Abstract:
We present a detailed study of the spatial resolution of our time-resolved neutron imaging detector utilizing a new neutron position reconstruction method that improves both spatial resolution and event reconstruction efficiency. Our prototype detector system, employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data…
▽ More
We present a detailed study of the spatial resolution of our time-resolved neutron imaging detector utilizing a new neutron position reconstruction method that improves both spatial resolution and event reconstruction efficiency. Our prototype detector system, employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data acquisition system, combines 100μm-level spatial and sub-μs time resolutions with excellent gamma rejection and high data rates, making it well suited for applications in neutron radiography at high-intensity, pulsed neutron sources. From data taken at the Materials and Life Science Experimental Facility within the Japan Proton Accelerator Research Complex (J-PARC), the spatial resolution was found to be approximately Gaussian with a sigma of 103.48 +/- 0.77 μm (after correcting for beam divergence). This is a significant improvement over that achievable with our previous reconstruction method (334 +/- 13 μm), and compares well with conventional neutron imaging detectors and with other high-rate detectors currently under development. Further, a detector simulation indicates that a spatial resolution of less than 60 μm may be possible with optimization of the gas characteristics and μPIC structure. We also present an example of imaging combined with neutron resonance absorption spectroscopy.
△ Less
Submitted 16 May, 2013;
originally announced May 2013.
-
XMASS detector
Authors:
K. Abe,
K. Hieda,
K. Hiraide,
S. Hirano,
Y. Kishimoto,
K. Kobayashi,
S. Moriyama,
K. Nakagawa,
M. Nakahata,
H. Nishiie,
H. Ogawa,
N. Oka,
H. Sekiya,
A. Shinozaki,
Y. Suzuki,
A. Takeda,
O. Takachio,
K. Ueshima,
D. Umemoto,
M. Yamashita,
B. S. Yang,
S. Tasaka,
J. Liu,
K. Martens,
K. Hosokawa
, et al. (23 additional authors not shown)
Abstract:
The XMASS project aims to detect dark matter, pp and $^{7}$Be solar neutrinos, and neutrinoless double beta decay using ultra pure liquid xenon. The first phase of the XMASS experiment searches for dark matter. In this paper, we describe the XMASS detector in detail, including its configuration, data acquisition equipment and calibration system.
The XMASS project aims to detect dark matter, pp and $^{7}$Be solar neutrinos, and neutrinoless double beta decay using ultra pure liquid xenon. The first phase of the XMASS experiment searches for dark matter. In this paper, we describe the XMASS detector in detail, including its configuration, data acquisition equipment and calibration system.
△ Less
Submitted 13 January, 2013;
originally announced January 2013.
-
Search for solar axions in XMASS, a large liquid-xenon detector
Authors:
K. Abe,
K. Hieda,
K. Hiraide,
S. Hirano,
Y. Kishimoto,
K. Kobayashi,
S. Moriyama,
K. Nakagawa,
M. Nakahata,
H. Ogawa,
N. Oka,
H. Sekiya,
A. Shinozaki Y. Suzuki,
A. Takeda,
O. Takachio,
K. Ueshima,
D. Umemoto,
M. Yamashita,
B. S. Yang,
S. Tasaka,
J. Liu,
K. Martens,
K. Hosokawa,
K. Miuchi,
A. Murata
, et al. (21 additional authors not shown)
Abstract:
XMASS, a low-background, large liquid-xenon detector, was used to search for solar axions that would be produced by bremsstrahlung and Compton effects in the Sun. With an exposure of 5.6ton days of liquid xenon, the model-independent limit on the coupling for mass $\ll$ 1keV is $|g_{aee}|< 5.4\times 10^{-11}$ (90% C.L.), which is a factor of two stronger than the existing experimental limit. The b…
▽ More
XMASS, a low-background, large liquid-xenon detector, was used to search for solar axions that would be produced by bremsstrahlung and Compton effects in the Sun. With an exposure of 5.6ton days of liquid xenon, the model-independent limit on the coupling for mass $\ll$ 1keV is $|g_{aee}|< 5.4\times 10^{-11}$ (90% C.L.), which is a factor of two stronger than the existing experimental limit. The bounds on the axion masses for the DFSZ and KSVZ axion models are 1.9 and 250eV, respectively. In the mass range of 10-40keV, this study produced the most stringent limit, which is better than that previously derived from astrophysical arguments regarding the Sun to date.
△ Less
Submitted 29 May, 2013; v1 submitted 26 December, 2012;
originally announced December 2012.
-
Neutron imaging detector based on the muPIC micro-pixel chamber
Authors:
J. D. Parker,
K. Hattori,
H. Fujioka,
M. Harada,
S. Iwaki,
S. Kabuki,
Y. Kishimoto,
H. Kubo,
S. Kurosawa,
K. Miuchi,
T. Nagae,
H. Nishimura,
T. Oku,
T. Sawano,
T. Shinohara,
J. Suzuki,
A. Takada,
T. Tanimori,
K. Ueno
Abstract:
We have developed a prototype time-resolved neutron imaging detector employing the micro-pixel chamber (muPIC), a micro-pattern gaseous detector, coupled with a field programmable gate array-based data acquisition system for applications in neutron radiography at high-intensity neutron sources. The prototype system, with an active area of 10cm x 10cm and operated at a gas pressure of 2 atm, measur…
▽ More
We have developed a prototype time-resolved neutron imaging detector employing the micro-pixel chamber (muPIC), a micro-pattern gaseous detector, coupled with a field programmable gate array-based data acquisition system for applications in neutron radiography at high-intensity neutron sources. The prototype system, with an active area of 10cm x 10cm and operated at a gas pressure of 2 atm, measures both the energy deposition (via time-over-threshold) and 3-dimensional track of each neutron-induced event, allowing the reconstruction of the neutron interaction point with improved accuracy. Using a simple position reconstruction algorithm, a spatial resolution of 349 +/- 36 microns was achieved, with further improvement expected. The detailed tracking allows strong rejection of background gamma-rays, resulting in an effective gamma sensitivity of 10^-12 or less, coupled with stable, robust neutron identification. The detector also features a time resolution of 0.6 microseconds.
△ Less
Submitted 26 September, 2012;
originally announced September 2012.
-
Scintillation-only Based Pulse Shape Discrimination for Nuclear and Electron Recoils in Liquid Xenon
Authors:
K. Ueshima,
K. Abe,
K. Hiraide,
S. Hirano,
Y. Kishimoto,
K. Kobayashi,
Y. Koshio,
J. Liu,
K. Martens,
S. Moriyama,
M. Nakahata,
H. Nishiie,
H. Ogawa,
H. Sekiya,
A. Shinozaki,
Y. Suzuki,
A. Takeda,
M. Yamashita,
K. Fujii,
I. Murayama,
S. Nakamura,
K. Otsuka,
Y. Takeuchi,
Y. Fukuda,
K. Nishijima
, et al. (12 additional authors not shown)
Abstract:
In a dedicated test setup at the Kamioka Observatory we studied pulse shape discrimination (PSD) in liquid xenon (LXe) for dark matter searches. PSD in LXe was based on the observation that scintillation light from electron events was emitted over a longer period of time than that of nuclear recoil events, and our method used a simple ratio of early to total scintillation light emission in a singl…
▽ More
In a dedicated test setup at the Kamioka Observatory we studied pulse shape discrimination (PSD) in liquid xenon (LXe) for dark matter searches. PSD in LXe was based on the observation that scintillation light from electron events was emitted over a longer period of time than that of nuclear recoil events, and our method used a simple ratio of early to total scintillation light emission in a single scintillation event. Requiring an efficiency of 50% for nuclear recoil retention we reduced the electron background to 7.7\pm1.1(stat)\pm1.2 0.6(sys)\times10-2 at energies between 4.8 and 7.2 keVee and to 7.7\pm2.8(stat)\pm2.5 2.8(sys)\times10-3 at energies between 9.6 and 12 keVee for a scintillation light yield of 20.9 p.e./keV. Further study was done by masking some of that light to reduce this yield to 4.6 p.e./keV, the same method results in an electron event reduction of 2.4\pm0.2(stat)\pm0.3 0.2(sys)\times10-1 for the lower of the energy regions above. We also observe that in contrast to nuclear recoils the fluctuations in our early to total ratio for electron events are larger than expected from statistical fluctuations.
△ Less
Submitted 11 June, 2011;
originally announced June 2011.
-
Quasilinear analysis of the zonal flow back-reaction on ion-temperature-gradient mode turbulence
Authors:
Johan Anderson,
Jiquan Li,
Yasuaki Kishimoto,
Eun-jin Kim
Abstract:
There is strong evidence in favor for zonal flow suppression of the Ion-Temperature-Gradient (ITG) mode turbulence, specifically close to the linear stability threshold. The present letter attempts to analytically calculate the effects of zonal flow suppression of the ITG turbulence through deriving a modified dispersion relation including the back-reaction of the zonal flows on the ITG turbulen…
▽ More
There is strong evidence in favor for zonal flow suppression of the Ion-Temperature-Gradient (ITG) mode turbulence, specifically close to the linear stability threshold. The present letter attempts to analytically calculate the effects of zonal flow suppression of the ITG turbulence through deriving a modified dispersion relation including the back-reaction of the zonal flows on the ITG turbulence based on the quasilinear theory. The results are manifested in a reduction of the linear growth rate and an increase in the effective linear ITG threshold.
△ Less
Submitted 14 January, 2009;
originally announced January 2009.
-
Effects of parallel ion motion on zonal flow generation in ion-temperature-gradient mode turbulence
Authors:
J. Anderson,
J. Li,
Y. Kishimoto
Abstract:
The role of parallel ion motion for zonal flow generation in ion-temperature-gradient (ITG) mode turbulence is investigated with focus on the effects of acoustic modes and toroidicity on the zonal flow. One possible reason for the weak suppression of ITG turbulence by zonal flows found in experiments in the Columbia Linear Machine (CLM) [Phys. Plasmas {\bf 13} 055905 (2006)] might be due to the…
▽ More
The role of parallel ion motion for zonal flow generation in ion-temperature-gradient (ITG) mode turbulence is investigated with focus on the effects of acoustic modes and toroidicity on the zonal flow. One possible reason for the weak suppression of ITG turbulence by zonal flows found in experiments in the Columbia Linear Machine (CLM) [Phys. Plasmas {\bf 13} 055905 (2006)] might be due to the small toroidicity ($ε_n = 2L_n/R$) in the experiment. The zonal flow is often directly dependent on the ITG mode and the coupling of zonal flow to acoustic modes and hence is directly affected by any change of the relevant parameters. The model consists of the continuity, temperature and parallel ion momentum equations for the ITG turbulence. The zonal flow time evolution is described by a Hasegawa-Mima like equation and a fifth order zonal flow dispersion relation is derived. The results are interpreted in terms of quality of zonal flows, i.e., the ratio of growth rate and real frequency ($Q = Ω^{IM}/Ω^{RE}$). It is found that the quality of the zonal flow rapidly decreases with decreasing toroidicity.
△ Less
Submitted 14 January, 2009;
originally announced January 2009.
-
Comparison of multi-scale analysis models applied to zonal flow generation in ion-temperature-gradient mode turbulence
Authors:
J. Anderson,
Y. Kishimoto
Abstract:
During the past years the understanding of the multi-scale interaction problems have increased significantly. However, at present there exists a range of different analytical models for investigating multi-scale interactions and hardly any specific comparisons have been performed among these models. In this work, two different models for the generation of zonal flows from ion-temperature-gradien…
▽ More
During the past years the understanding of the multi-scale interaction problems have increased significantly. However, at present there exists a range of different analytical models for investigating multi-scale interactions and hardly any specific comparisons have been performed among these models. In this work, two different models for the generation of zonal flows from ion-temperature-gradient (ITG) background turbulence are discussed and compared. The methods used is the coherent mode coupling model and the wave kinetic equation model (WKE). It is shown that the two models give qualitatively the same results even though the assumption on the spectral difference is used in the (WKE) approach.
△ Less
Submitted 14 January, 2009;
originally announced January 2009.