Combined Pre-Supernova Alert System with Kamland and Super-Kamiokande
Authors:
KamLAND,
Super-Kamiokande Collaborations,
:,
Seisho Abe,
Minori Eizuka,
Sawako Futagi,
Azusa Gando,
Yoshihito Gando,
Shun Goto,
Takahiko Hachiya,
Kazumi Hata,
Koichi Ichimura,
Sei Ieki,
Haruo Ikeda,
Kunio Inoue,
Koji Ishidoshiro,
Yuto Kamei,
Nanami Kawada,
Yasuhiro Kishimoto,
Masayuki Koga,
Maho Kurasawa,
Tadao Mitsui,
Haruhiko Miyake,
Daisuke Morita,
Takeshi Nakahata
, et al. (290 additional authors not shown)
Abstract:
Preceding a core-collapse supernova, various processes produce an increasing amount of neutrinos of all flavors characterized by mounting energies from the interior of massive stars. Among them, the electron antineutrinos are potentially detectable by terrestrial neutrino experiments such as KamLAND and Super-Kamiokande via inverse beta decay interactions. Once these pre-supernova neutrinos are ob…
▽ More
Preceding a core-collapse supernova, various processes produce an increasing amount of neutrinos of all flavors characterized by mounting energies from the interior of massive stars. Among them, the electron antineutrinos are potentially detectable by terrestrial neutrino experiments such as KamLAND and Super-Kamiokande via inverse beta decay interactions. Once these pre-supernova neutrinos are observed, an early warning of the upcoming core-collapse supernova can be provided. In light of this, KamLAND and Super-Kamiokande, both located in the Kamioka mine in Japan, have been monitoring pre-supernova neutrinos since 2015 and 2021, respectively. Recently, we performed a joint study between KamLAND and Super-Kamiokande on pre-supernova neutrino detection. A pre-supernova alert system combining the KamLAND detector and the Super-Kamiokande detector was developed and put into operation, which can provide a supernova alert to the astrophysics community. Fully leveraging the complementary properties of these two detectors, the combined alert is expected to resolve a pre-supernova neutrino signal from a 15 M$_{\odot}$ star within 510 pc of the Earth, at a significance level corresponding to a false alarm rate of no more than 1 per century. For a Betelgeuse-like model with optimistic parameters, it can provide early warnings up to 12 hours in advance.
△ Less
Submitted 1 July, 2024; v1 submitted 15 April, 2024;
originally announced April 2024.
-
First Study of the PIKACHU Project: Development and Evaluation of High-Purity Gd$_3$Ga$_3$Al$_2$O$_{12}$:Ce Crystals for $^{160}$Gd Double Beta Decay Search
Authors:
Takumi Omori,
Takashi Iida,
Azusa Gando,
Keishi Hosokawa,
Kei Kamada,
Keita Mizukoshi,
Yasuhiro Shoji,
Masao Yoshino,
Ken-Ichi Fushimi,
Hisanori Suzuki,
Kotaro Takahashi
Abstract:
Uncovering neutrinoless double beta decay (0$ν$2$β$) is crucial for confirming neutrinos' Majorana characteristics. The decay rate of 0$νββ$ is theoretically uncertain, influenced by nuclear matrix elements that vary across nuclides. To reduce this uncertainty, precise measurement of the half-life of neutrino-emitting double beta decay (2$ν$2$β$) in different nuclides is essential.
We have launc…
▽ More
Uncovering neutrinoless double beta decay (0$ν$2$β$) is crucial for confirming neutrinos' Majorana characteristics. The decay rate of 0$νββ$ is theoretically uncertain, influenced by nuclear matrix elements that vary across nuclides. To reduce this uncertainty, precise measurement of the half-life of neutrino-emitting double beta decay (2$ν$2$β$) in different nuclides is essential.
We have launched the PIKACHU (Pure Inorganic scintillator experiment in KAmioka for CHallenging Underground sciences) project to fabricate high-purity Ce-doped Gd$_{3}$Ga$_{3}$Al$_{2}$O$_{12}$ (GAGG) single crystals and use them to study the double beta decay of $^{160}$Gd. Predictions from two theoretical models on nuclear matrix element calculations for 2$ν$2$β$ in $^{160}$Gd show a significant discrepancy in estimated half-lives, differing by approximately an order of magnitude. If the lower half-life estimation holds true, detecting 2$ν$2$β$ in $^{160}$Gd could be achievable with a sensitivity enhancement slightly more than an order of magnitude compared to prior investigations using Ce-doped Gd$_2$SiO$_5$ (GSO) crystal. We have successfully developed GAGG crystals with purity levels surpassing previous standards through refined purification and selection of raw materials. Our experiments with these crystals indicate the feasibility of reaching sensitivities exceeding those of earlier studies. This paper discusses the ongoing development and scintillator performance evaluation of High-purity GAGG crystals, along with the anticipated future prospects of the PIKACHU experiment.
△ Less
Submitted 9 February, 2024;
originally announced February 2024.
-
Search for Charged Excited States of Dark Matter with KamLAND-Zen
Authors:
KamLAND-Zen collaboration,
:,
S. Abe,
M. Eizuka,
S. Futagi,
A. Gando,
Y. Gando,
S. Goto,
T. Hachiya,
K. Hata,
K. Hosokawa,
K. Ichimura,
S. Ieki,
H. Ikeda,
K. Inoue,
K. Ishidoshiro,
Y. Kamei,
N. Kawada,
Y. Kishimoto,
M. Koga,
M. Kurasawa,
T. Mitsui,
H. Miyake,
D. Morita,
T. Nakahata
, et al. (44 additional authors not shown)
Abstract:
Particle dark matter could belong to a multiplet that includes an electrically charged state. WIMP dark matter ($χ^{0}$) accompanied by a negatively charged excited state ($χ^{-}$) with a small mass difference (e.g. $<$ 20 MeV) can form a bound-state with a nucleus such as xenon. This bound-state formation is rare and the released energy is $\mathcal{O}(1-10$) MeV depending on the nucleus, making…
▽ More
Particle dark matter could belong to a multiplet that includes an electrically charged state. WIMP dark matter ($χ^{0}$) accompanied by a negatively charged excited state ($χ^{-}$) with a small mass difference (e.g. $<$ 20 MeV) can form a bound-state with a nucleus such as xenon. This bound-state formation is rare and the released energy is $\mathcal{O}(1-10$) MeV depending on the nucleus, making large liquid scintillator detectors suitable for detection. We searched for bound-state formation events with xenon in two experimental phases of the KamLAND-Zen experiment, a xenon-doped liquid scintillator detector. No statistically significant events were observed. For a benchmark parameter set of WIMP mass $m_{χ^{0}} = 1$ TeV and mass difference $Δm = 17$ MeV, we set the most stringent upper limits on the recombination cross section times velocity $\langleσv\rangle$ and the decay-width of $χ^{-}$ to $9.2 \times 10^{-30}$ ${\rm cm^3/s}$ and $8.7 \times 10^{-14}$ GeV, respectively at 90% confidence level.
△ Less
Submitted 3 July, 2024; v1 submitted 16 November, 2023;
originally announced November 2023.
-
Radiopurity of NaI(Tl) crystals for PICOLON dark matter experiment
Authors:
K. Kotera,
D. Chernyak,
H. Ejiri,
K. Fushimi,
K. Hata,
R. Hazama,
T. Iida,
H. Ikeda,
K. Imagawa,
K. Inoue,
H. Ito,
T. Kishimoto,
M. Koga,
A. Kozlov,
K. Nakamura,
R. Orito,
T. Shima,
Y. Takemoto,
S. Umehara,
Y. Urano,
K. Yasuda,
S. Yoshida
Abstract:
The dark matter observation claim by the DAMA/LIBRA collaboration has been a long-standing puzzle within the particle physics community. Efforts of other research groups to verify the claim have been insufficient by significant radioactivity of present NaI(Tl) crystals. PICOLON (Pure Inorganic Crystal Observatory for LOw-energy Neut(ra)lino) experiment conducts independent search for Weakly Intera…
▽ More
The dark matter observation claim by the DAMA/LIBRA collaboration has been a long-standing puzzle within the particle physics community. Efforts of other research groups to verify the claim have been insufficient by significant radioactivity of present NaI(Tl) crystals. PICOLON (Pure Inorganic Crystal Observatory for LOw-energy Neut(ra)lino) experiment conducts independent search for Weakly Interacting Massive Particles (WIMPs) using NaI(Tl) crystals. Our NaI(Tl) crystal manufactured in 2020 (Ingot #85) reached the same purity level as DAMA/LIBRA crystals. In this report, we describe the radiopurity of the new Ingot #94 crystal produced using the same purification technique as Ingot #85. The $α$-ray events were selected by pulse-shape discrimination method. The impurities in the Ingot #94, $^{232}$Th, $^{226}$Ra and $^{210}$Po radioactivity were $4.6\pm 1.2~\mathrm{μBq/kg}$, $7.9\pm 4.4~\mathrm{μBq/kg}$, and $19\pm 6~\mathrm{μBq/kg}$, which are equivalent to those of the DAMA/LIBRA crystals. The background rate in the energy region of 2-6 keV , was 2-5 events/d/kg/keV without applying a veto trigger.
△ Less
Submitted 25 September, 2023;
originally announced September 2023.
-
Measurement of cosmic-ray muon spallation products in a xenon-loaded liquid scintillator with KamLAND
Authors:
KamLAND-Zen Collaboration,
:,
S. Abe,
S. Asami,
M. Eizuka,
S. Futagi,
A. Gando,
Y. Gando,
T. Gima,
A. Goto,
T. Hachiya,
K. Hata,
K. Hosokawa,
K. Ichimura,
S. Ieki,
H. Ikeda,
K. Inoue,
K. Ishidoshiro,
Y. Kamei,
N. Kawada,
Y. Kishimoto,
M. Koga,
M. Kurasawa,
T. Mitsui,
H. Miyake
, et al. (42 additional authors not shown)
Abstract:
Cosmic-ray muons produce various radioisotopes when passing through material. These spallation products can be backgrounds for rare event searches such as in solar neutrino, double-beta decay, and dark matter search experiments. The KamLAND-Zen experiment searches for neutrinoless double-beta decay in 745kg of xenon dissolved in liquid scintillator. The experiment includes dead-time-free electroni…
▽ More
Cosmic-ray muons produce various radioisotopes when passing through material. These spallation products can be backgrounds for rare event searches such as in solar neutrino, double-beta decay, and dark matter search experiments. The KamLAND-Zen experiment searches for neutrinoless double-beta decay in 745kg of xenon dissolved in liquid scintillator. The experiment includes dead-time-free electronics with a high efficiency for detecting muon-induced neutrons. The production yields of different radioisotopes are measured with a combination of delayed coincidence techniques, newly developed muon reconstruction and xenon spallation identification methods. The observed xenon spallation products are consistent with results from the FLUKA and Geant4 simulation codes.
△ Less
Submitted 23 January, 2023;
originally announced January 2023.
-
Direct dark matter searches with the full data set of XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
N. Kato,
S. Moriyama,
M. Nakahata,
K. Sato,
H. Sekiya,
T. Suzuki,
Y. Suzuki,
A. Takeda,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. H. Kim,
Y. Itow,
K. Martens,
A. Mason,
M. Yamashita,
K. Miuchi,
Y. Takeuchi,
K. B. Lee,
M. K. Lee,
Y. Fukuda,
H. Ogawa
, et al. (7 additional authors not shown)
Abstract:
Various WIMP dark matter searches using the full data set of XMASS-I, a single-phase liquid xenon detector, are reported in this paper. Stable XMASS-I data taking accumulated a total live time of 1590.9 days between November 20, 2013 and February 1, 2019 with an analysis threshold of ${\rm 1.0\,keV_{ee}}$. In the latter half of data taking a lower analysis threshold of ${\rm 0.5\,keV_{ee}}$ was al…
▽ More
Various WIMP dark matter searches using the full data set of XMASS-I, a single-phase liquid xenon detector, are reported in this paper. Stable XMASS-I data taking accumulated a total live time of 1590.9 days between November 20, 2013 and February 1, 2019 with an analysis threshold of ${\rm 1.0\,keV_{ee}}$. In the latter half of data taking a lower analysis threshold of ${\rm 0.5\,keV_{ee}}$ was also available through a new low threshold trigger. Searching for a WIMP signal in the detector's 97~kg fiducial volume yielded a limit on the WIMP-nucleon scattering cross section of ${\rm 1.4\times 10^{-44}\, cm^{2}}$ for a ${\rm 60\,GeV/c^{2}}$ WIMP at the 90$\%$ confidence level. We also searched for WIMP induced annual modulation signatures in the detector's whole target volume, containing 832~kg of liquid xenon. For nuclear recoils of a ${\rm 8\,GeV/c^{2}}$ WIMP this analysis yielded a 90\% CL cross section limit of ${\rm 2.3\times 10^{-42}\, cm^{2}}$. At a WIMP mass of ${\rm 0.5\, GeV/c^{2}}$ the Migdal effect and Bremsstrahlung signatures were evaluated and lead to 90\% CL cross section limits of ${\rm 1.4\times 10^{-35}\, cm^{2}}$ and ${\rm 1.1\times 10^{-33}\, cm^{2}}$ respectively.
△ Less
Submitted 1 September, 2023; v1 submitted 11 November, 2022;
originally announced November 2022.
-
Abundances of uranium and thorium elements in Earth estimated by geoneutrino spectroscopy
Authors:
S. Abe,
S. Asami,
M. Eizuka,
S. Futagi,
A. Gando,
Y. Gando,
T. Gima,
A. Goto,
T. Hachiya,
K. Hata,
K. Hosokawa,
K. Ichimura,
S. Ieki,
H. Ikeda,
K. Inoue,
K. Ishidoshiro,
Y. Kamei,
N. Kawada,
Y. Kishimoto,
M. Koga,
M. Kurasawa,
N. Maemura,
T. Mitsui,
H. Miyake,
T. Nakahata
, et al. (43 additional authors not shown)
Abstract:
The decay of the primordial isotopes $^{238}\mathrm{U}$, $^{235}\mathrm{U}$, $^{232}\mathrm{Th}$, and $^{40}\mathrm{K}$ have contributed to the terrestrial heat budget throughout the Earth's history. Hence the individual abundance of those isotopes are key parameters in reconstructing contemporary Earth model. The geoneutrinos produced by the radioactive decays of uranium and thorium have been obs…
▽ More
The decay of the primordial isotopes $^{238}\mathrm{U}$, $^{235}\mathrm{U}$, $^{232}\mathrm{Th}$, and $^{40}\mathrm{K}$ have contributed to the terrestrial heat budget throughout the Earth's history. Hence the individual abundance of those isotopes are key parameters in reconstructing contemporary Earth model. The geoneutrinos produced by the radioactive decays of uranium and thorium have been observed with the Kamioka Liquid-Scintillator Antineutrino Detector (KamLAND). Those measurements have been improved with more than 18-year observation time, and improvements in detector background levels mainly by an 8-year almost rector-free period now permit spectroscopy with geoneutrinos. Our results yield the first constraint on both uranium and thorium heat contributions. Herein the KamLAND result is consistent with geochemical estimations based on elemental abundances of chondritic meteorites and mantle peridotites. The High-Q model is disfavored at 99.76% C.L. and a fully radiogenic model is excluded at 5.2$σ$ assuming a homogeneous heat producing element distribution in the mantle.
△ Less
Submitted 13 August, 2022; v1 submitted 30 May, 2022;
originally announced May 2022.
-
Search for neutrinoless quadruple beta decay of $^{136}$Xe in XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
N. Kato,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
K. Sato,
H. Sekiya,
T. Suzuki,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. H. Kim,
R. Ishii,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens
, et al. (12 additional authors not shown)
Abstract:
A search for the neutrinoless quadruple beta decay of $^{136}$Xe was conducted with the liquid-xenon detector XMASS-I using $\rm 327\; kg \times 800.0 \; days$ of the exposure. The pulse shape discrimination based on the scintillation decay time constant which distinguishes $γ$-rays including the signal and $β$-rays was used to enhance the search sensitivity. No significant signal excess was obser…
▽ More
A search for the neutrinoless quadruple beta decay of $^{136}$Xe was conducted with the liquid-xenon detector XMASS-I using $\rm 327\; kg \times 800.0 \; days$ of the exposure. The pulse shape discrimination based on the scintillation decay time constant which distinguishes $γ$-rays including the signal and $β$-rays was used to enhance the search sensitivity. No significant signal excess was observed from the energy spectrum fitting with precise background evaluation, and we set a lower limit of the half life of 3.7 $\times$ 10$^{24}$ years at 90$\%$ confidence level. This is the first experimental constraint of the neutrinoless quadruple beta decay of $^{136}$Xe.
△ Less
Submitted 5 August, 2022; v1 submitted 10 May, 2022;
originally announced May 2022.
-
Search for the Majorana Nature of Neutrinos in the Inverted Mass Ordering Region with KamLAND-Zen
Authors:
KamLAND-Zen Collaboration,
:,
S. Abe,
S. Asami,
M. Eizuka,
S. Futagi,
A. Gando,
Y. Gando,
T. Gima,
A. Goto,
T. Hachiya,
K. Hata,
S. Hayashida,
K. Hosokawa,
K. Ichimura,
S. Ieki,
H. Ikeda,
K. Inoue,
K. Ishidoshiro,
Y. Kamei,
N. Kawada,
Y. Kishimoto,
M. Koga,
M. Kurasawa,
N. Maemura
, et al. (50 additional authors not shown)
Abstract:
The KamLAND-Zen experiment has provided stringent constraints on the neutrinoless double-beta ($0νββ$) decay half-life in $^{136}$Xe using a xenon-loaded liquid scintillator. We report an improved search using an upgraded detector with almost double the amount of xenon and an ultralow radioactivity container, corresponding to an exposure of 970 kg yr of $^{136}$Xe. These new data provide valuable…
▽ More
The KamLAND-Zen experiment has provided stringent constraints on the neutrinoless double-beta ($0νββ$) decay half-life in $^{136}$Xe using a xenon-loaded liquid scintillator. We report an improved search using an upgraded detector with almost double the amount of xenon and an ultralow radioactivity container, corresponding to an exposure of 970 kg yr of $^{136}$Xe. These new data provide valuable insight into backgrounds, especially from cosmic muon spallation of xenon, and have required the use of novel background rejection techniques. We obtain a lower limit for the $0νββ$ decay half-life of $T_{1/2}^{0ν} > 2.3 \times 10^{26}$ yr at 90% C.L., corresponding to upper limits on the effective Majorana neutrino mass of 36-156 meV using commonly adopted nuclear matrix element calculations.
△ Less
Submitted 16 February, 2023; v1 submitted 4 March, 2022;
originally announced March 2022.
-
PICOLON dark matter search project
Authors:
K. Fushimi,
D. Chernyak,
H. Ejiri,
K. Hata,
R. Hazama,
T. Iida,
H. Ikeda,
K. Imagawa,
K. Inoue,
H. Ishiura,
H. Ito,
T. Kishimoto,
M. Koga,
K. Kotera,
A. Kozlov,
K. Nakamura,
R. Orito,
T. Shima,
Y. Takemoto,
S. Umehara,
Y. Urano,
Y. Yamamoto,
K. Yasuda,
S. Yoshida
Abstract:
PICOLON (Pure Inorganic Crystal Observatory for LOw-energy Neutr(al)ino) aims to search for cosmic dark matter by high purity NaI(Tl) scintillator. We developed extremely pure NaI(Tl) crystal by hybrid purification method. The recent result of $^{210}$Pb in our NaI(Tl) is less than 5.7 $μ$Bq/kg. We will report the test experiment in the low-background measurement at Kamioka Underground Laboratory.…
▽ More
PICOLON (Pure Inorganic Crystal Observatory for LOw-energy Neutr(al)ino) aims to search for cosmic dark matter by high purity NaI(Tl) scintillator. We developed extremely pure NaI(Tl) crystal by hybrid purification method. The recent result of $^{210}$Pb in our NaI(Tl) is less than 5.7 $μ$Bq/kg. We will report the test experiment in the low-background measurement at Kamioka Underground Laboratory. The sensitivity for annual modulating signals and finding dark matter particles will be discussed.
△ Less
Submitted 19 December, 2021;
originally announced December 2021.
-
Dark matter search with high purity NaI(Tl) scintillator
Authors:
K. Fushimi,
Y. Kanemitsu,
K. Kotera,
D. Chernyak,
H. Ejiri,
K. Hata,
R. Hazama,
T. Iida,
H. Ikeda,
K. Imagawa,
K. Inoue,
H. Ishiura,
H. Ito,
T. Kisimoto,
M. Koga,
A. Kozlov,
K. Nakamura,
R. Orito,
T. Shima,
Y. Takemoto,
S. Umehara,
Y. Urano,
K. Yasuda,
S. Yoshida
Abstract:
A dark matter search project needs and extremely low background radiation detector since the expected event rate of dark matter is less than a few events in one year in one tonne of the detector mass. The authors developed a highly radiopure NaI(Tl) crystal to search for dark matter. The best combination of the purification methods was developed, resulting $^{\mathrm{nat}}$K and $^{210}$Pb were le…
▽ More
A dark matter search project needs and extremely low background radiation detector since the expected event rate of dark matter is less than a few events in one year in one tonne of the detector mass. The authors developed a highly radiopure NaI(Tl) crystal to search for dark matter. The best combination of the purification methods was developed, resulting $^{\mathrm{nat}}$K and $^{210}$Pb were less than 20 ppb and 5.7 $μ$Bq/kg, respectively.
The authors will construct a large volume detector system with high-purity NaI(Tl) crystals. The design and the performance of the prototype detector module will be reported in this article.
△ Less
Submitted 29 June, 2021;
originally announced June 2021.
-
The nylon balloon for xenon loaded liquid scintillator in KamLAND-Zen 800 neutrinoless double-beta decay search experiment
Authors:
KamLAND-Zen collaboration,
:,
Y. Gando,
A. Gando,
T. Hachiya,
S. Hayashida,
K. Hosokawa,
H. Ikeda,
T. Mitsui,
T. Nakada,
S. Obara,
H. Ozaki,
J. Shirai,
K. Ueshima,
H. Watanabe,
S. Abe,
K. Hata,
A. Hayashi,
Y. Honda,
S. Ieki,
K. Inoue,
K. Ishidoshiro,
S. Ishikawa,
Y. Kamei,
K. Kamizawa
, et al. (49 additional authors not shown)
Abstract:
The KamLAND-Zen 800 experiment is searching for the neutrinoless double-beta decay of $^{136}$Xe by using $^{136}$Xe-loaded liquid scintillator. The liquid scintillator is enclosed inside a balloon made of thin, transparent, low-radioactivity film that we call Inner Balloon (IB). The IB, apart from guaranteeing the liquid containment, also allows to minimize the background from cosmogenic muon-spa…
▽ More
The KamLAND-Zen 800 experiment is searching for the neutrinoless double-beta decay of $^{136}$Xe by using $^{136}$Xe-loaded liquid scintillator. The liquid scintillator is enclosed inside a balloon made of thin, transparent, low-radioactivity film that we call Inner Balloon (IB). The IB, apart from guaranteeing the liquid containment, also allows to minimize the background from cosmogenic muon-spallation products and $^{8}$B solar neutrinos. Indeed these events could contribute to the total counts in the region of interest around the Q-value of the double-beta decay of $^{136}$Xe. In this paper, we present an overview of the IB and describe the various steps of its commissioning minimizing the radioactive contaminations, from the material selection, to the fabrication of the balloon and its installation inside the KamLAND detector. Finally, we show the impact of the IB on the KamLAND background as measured by the KamLAND detector itself.
△ Less
Submitted 4 June, 2021; v1 submitted 21 April, 2021;
originally announced April 2021.
-
Development of highly radiopure NaI(Tl) scintillator for PICOLON dark matter search project
Authors:
K. Fushimi,
Y. Kanemitsu,
S. Hirata,
D. Chernyak,
R. Hazama,
H. Ikeda,
K. Imagawa,
H. Ishiura,
H. Ito,
T. Kisimoto,
A. Kozlov,
Y. Takemoto,
K. Yasuda,
H. Ejiri,
K. Hata,
T. Iida,
K. Inoue,
M. Koga,
K. Nakamura,
R. Orito,
T. Shima,
S. Umehara,
S. Yoshida
Abstract:
The highly radiopure NaI(Tl) was developed to search for particle candidates of dark matter. The optimized methods were combined to reduce various radioactive impurities. The $^{40}$K was effectively reduced by the re-crystallization method. The progenies of the decay chains of uranium and thorium were reduced by appropriate resins. The concentration of natural potassium in NaI(Tl) crystal was red…
▽ More
The highly radiopure NaI(Tl) was developed to search for particle candidates of dark matter. The optimized methods were combined to reduce various radioactive impurities. The $^{40}$K was effectively reduced by the re-crystallization method. The progenies of the decay chains of uranium and thorium were reduced by appropriate resins. The concentration of natural potassium in NaI(Tl) crystal was reduced down to 20 ppb. Concentrations of alpha-ray emitters were successfully reduced by appropriate selection of resin. The present concentration of thorium series and 226Ra were $1.2 \pm1.4$ $μ$Bq/kg and $13\pm4$ $μ$Bq/kg, respectively. No significant excess in the concentration of $^{210}$Pb was obtained, and the upper limit was 5.7 $μ$Bq/kg at 90% C. L. The achieved level of radiopurity of NaI(Tl) crystals makes construction of a dark matter detector possible.
△ Less
Submitted 20 May, 2021; v1 submitted 3 January, 2021;
originally announced January 2021.
-
A study on energy resolution of CANDLES detector
Authors:
B. T. Khai,
S. Ajimura,
W. M. Chan,
K. Fushimi,
R. Hazama,
H. Hiraoka,
T. Iida,
K. Kanagawa,
H. Kino,
T. Kishimoto,
T. Maeda,
K. Nakajima,
M. Nomachi,
I. Ogawa,
T. Ohata,
K. Suzuki,
Y. Takemoto,
Y. Takihira,
Y. Tamagawa,
M. Tozawa,
M. Tsuzuki,
S. Umehara,
S. Yoshida
Abstract:
In a neutrinoless double-beta decay ($0νββ$) experiment, energy resolution is important to distinguish between $0νββ$ and background events. CAlcium fluoride for studies of Neutrino and Dark matters by Low Energy Spectrometer (CANDLES) discerns the $0νββ$ of $^{48}$Ca using a CaF$_2$ scintillator as the detector and source. Photomultiplier tubes (PMTs) collect scintillation photons. At the Q-value…
▽ More
In a neutrinoless double-beta decay ($0νββ$) experiment, energy resolution is important to distinguish between $0νββ$ and background events. CAlcium fluoride for studies of Neutrino and Dark matters by Low Energy Spectrometer (CANDLES) discerns the $0νββ$ of $^{48}$Ca using a CaF$_2$ scintillator as the detector and source. Photomultiplier tubes (PMTs) collect scintillation photons. At the Q-value of $^{48}$Ca, the current energy resolution (2.6%) exceeds the ideal statistical fluctuation of the number of photoelectrons (1.6%). Because of CaF$_2$'s long decay constant of 1000 ns, a signal integration within 4000 ns is used to calculate the energy. The baseline fluctuation ($σ_{baseline}$) is accumulated in the signal integration, thus degrading the energy resolution. This paper studies $σ_{baseline}$ in the CANDLES detector, which severely degrades the resolution by 1% at the Q-value of $^{48}$Ca. To avoid $σ_{\rm baseline}$, photon counting can be used to obtain the number of photoelectrons in each PMT; however, a significant photoelectron signal overlapping probability in each PMT causes missing photoelectrons in counting and reduces the energy resolution. "Partial photon counting" reduces $σ_{baseline}$ and minimizes photoelectron loss. We obtain improved energy resolutions of 4.5-4.0% at 1460.8 keV ($γ$-ray of $^{40}$K), and 3.3-2.9% at 2614.5 keV ($γ$-ray of $^{208}$Tl). The energy resolution at the Q-value is estimated to be improved from 2.6% to 2.2%, and the detector sensitivity for the $0νββ$ half-life of $^{48}$Ca can be improved by 1.09 times.
△ Less
Submitted 28 January, 2021; v1 submitted 24 September, 2020;
originally announced September 2020.
-
Low background measurement in CANDLES-III for studying the neutrino-less double beta decay of $^{48}$Ca
Authors:
S. Ajimura,
W. M. Chan,
K. Ichimura,
T. Ishikawa,
K. Kanagawa,
B. T. Khai,
T. Kishimoto,
H. Kino,
T. Maeda,
K. Matsuoka,
N. Nakatani,
M. Nomachi,
M. Saka,
K. Seki,
Y. Takemoto,
Y. Takihira,
D. Tanaka,
M. Tanaka,
K. Tetsuno,
V. T. T. Trang,
M. Tsuzuki,
S. Umehara,
K. Akutagawa,
T. Batpurev,
M. Doihara
, et al. (44 additional authors not shown)
Abstract:
We developed a CANDLES-III system to study the neutrino-less double beta (0$νββ$) decay of $^{48}$Ca. The proposed system employs 96 CaF$_{2}$ scintillation crystals (305 kg) with natural Ca ($^{\rm nat.}$Ca) isotope which corresponds 350\,g of $^{48}$Ca. External backgrounds were rejected using a 4$π$ active shield of a liquid scintillator surrounding the CaF$_2$ crystals. The internal background…
▽ More
We developed a CANDLES-III system to study the neutrino-less double beta (0$νββ$) decay of $^{48}$Ca. The proposed system employs 96 CaF$_{2}$ scintillation crystals (305 kg) with natural Ca ($^{\rm nat.}$Ca) isotope which corresponds 350\,g of $^{48}$Ca. External backgrounds were rejected using a 4$π$ active shield of a liquid scintillator surrounding the CaF$_2$ crystals. The internal backgrounds caused by the radioactive impurities within the CaF$_2$ crystals can be reduced effectively through analysis of the signal pulse shape. We analyzed the data obtained in the Kamioka underground for a live-time of 130.4\,days to evaluate the feasibility of the low background measurement with the CANDLES-III detector. Using Monte Carlo simulations, we estimated the background rate from the radioactive impurities in the CaF$_{2}$ crystals and the rate of high energy $γ$-rays caused by the (n, $γ$) reactions induced by environmental neutrons. The expected background rate was in a good agreement with the measured rate, i.e., approximately 10$^{-3}$ events/keV/yr/(kg of $^{\rm nat.}$Ca), in the 0$νββ$ window. In conclusion, the background candidates were estimated properly by comparing the measured energy spectrum with the background simulations. With this measurement method, we performed the first search for 0$νββ$ decay in a low background condition using a detector with a Ca isotope, in which the Ca present was not enriched, in a scale of hundreds of kg. The $^{48}$Ca isotope has a high potential for use in 0$νββ$ decay search, and is expected to be useful for the development of a next-generation detector for highly sensitive measurements.
△ Less
Submitted 19 April, 2021; v1 submitted 20 August, 2020;
originally announced August 2020.
-
Search for event bursts in XMASS-I associated with gravitational-wave events
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
T. Suzuki,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki,
B. D. Xu
, et al. (12 additional authors not shown)
Abstract:
We performed a search for event bursts in the XMASS-I detector associated with 11 gravitational-wave events detected during LIGO/Virgo's O1 and O2 periods. Simple and loose cuts were applied to the data collected in the full 832 kg xenon volume around the detection time of each gravitational-wave event. The data were divided into four energy regions ranging from keV to MeV. Without assuming any pa…
▽ More
We performed a search for event bursts in the XMASS-I detector associated with 11 gravitational-wave events detected during LIGO/Virgo's O1 and O2 periods. Simple and loose cuts were applied to the data collected in the full 832 kg xenon volume around the detection time of each gravitational-wave event. The data were divided into four energy regions ranging from keV to MeV. Without assuming any particular burst models, we looked for event bursts in sliding windows with various time width from 0.02 to 10 s. The search was conducted in a time window between $-$400 and $+$10,000 s from each gravitational-wave event. For the binary neutron star merger GW170817, no significant event burst was observed in the XMASS-I detector and we set 90% confidence level upper limits on neutrino fluence for the sum of all the neutrino flavors via coherent elastic neutrino-nucleus scattering. The obtained upper limit was (1.3-2.1)$\times 10^{11}$ cm$^{-2}$ under the assumption of a Fermi-Dirac spectrum with average neutrino energy of 20 MeV. The neutrino fluence limits for mono-energetic neutrinos in the energy range between 14 and 100 MeV were also calculated. Among the other 10 gravitational wave events detected as the binary black hole mergers, a burst candidate with a 3.0$σ$ significance was found at 1801.95-1803.95 s in the analysis for GW151012. However, no significant deviation from the background in the reconstructed energy and position distributions was found. Considering the additional look-elsewhere effect of analyzing the 11 GW events, the significance of finding such a burst candidate associated with any of them is 2.1$σ$.
△ Less
Submitted 30 December, 2020; v1 submitted 29 July, 2020;
originally announced July 2020.
-
Development of low-background photomultiplier tubes for liquid xenon detectors
Authors:
XMASS Collaboration,
K. Abe,
Y. Chen,
K. Hiraide,
K. Ichimura,
S. Imaizumi,
N. Kato,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
K. Sato,
H. Sekiya,
T. Suzuki,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. H. Kim,
R. Ishii,
Y. Itow,
K. Kanzawa
, et al. (14 additional authors not shown)
Abstract:
We successfully developed a new photomultiplier tube (PMT) with a three-inch diameter, convex-shaped photocathode, R13111. Its prominent features include good performance and ultra-low radioactivity. The convex-shaped photocathode realized a large photon acceptance and good timing resolution. Low radioactivity was achieved by three factors: (1) the glass material was synthesized using low-radioact…
▽ More
We successfully developed a new photomultiplier tube (PMT) with a three-inch diameter, convex-shaped photocathode, R13111. Its prominent features include good performance and ultra-low radioactivity. The convex-shaped photocathode realized a large photon acceptance and good timing resolution. Low radioactivity was achieved by three factors: (1) the glass material was synthesized using low-radioactive-contamination material; (2) the photocathode was produced with $^{39}$K-enriched potassium; and (3) the purest grade of aluminum material was used for the vacuum seal. As a result each R13111 PMT contains only about 0.4 mBq of $^{226}$Ra, less than 2 mBq of $^{238}$U, 0.3 mBq of $^{228}$Ra, 2 mBq of $^{40}$K and 0.2 mBq of $^{60}$Co. We also examined and resolved the intrinsic leakage of Xe gas into PMTs that was observed in several older models. We thus succeeded in developing a PMT that has low background, large angular acceptance with high collection efficiency, good timing resolution, and long-term stable operation. These features are highly desirable for experiments searching for rare events beyond the standard model, such as dark matter particle interactions and neutrinoless double beta decay events.
△ Less
Submitted 18 August, 2020; v1 submitted 1 June, 2020;
originally announced June 2020.
-
The energy calibration system for CANDLES using (n, γ) reaction
Authors:
T. Iida,
K. Mizukoshi,
T. Ohata,
T. Uehara,
T. Batpurev,
W. M. Chan,
K. Fushimi,
R. Hazama,
M. Ishikawa,
H. Kakubata,
K. Kanagawa,
S. Katagiri,
B. T. Khai,
T. Kishimoto,
X. Li,
T. Maeda,
K. Matsuoka,
K. Morishita,
M. Moser,
K. Nakajima,
M. Nomachi,
I. Ogawa,
M. Shokati,
K. Suzuki,
Y. Takemoto
, et al. (6 additional authors not shown)
Abstract:
CAlcium fluoride for the study of Neutrinos and Dark matters by Low-energy Spectrometer (CANDLES) searches for neutrino-less double beta decay of $^{48}$Ca using a CaF$_2$ scintillator array. A high Q-value of $^{48}$Ca at 4,272 keV enabled us to achieve very low background condition, however, at the same it causes difficulties in calibrating the detector's Q-value region because of the absence of…
▽ More
CAlcium fluoride for the study of Neutrinos and Dark matters by Low-energy Spectrometer (CANDLES) searches for neutrino-less double beta decay of $^{48}$Ca using a CaF$_2$ scintillator array. A high Q-value of $^{48}$Ca at 4,272 keV enabled us to achieve very low background condition, however, at the same it causes difficulties in calibrating the detector's Q-value region because of the absence of a standard high-energy $γ$-ray source. Therefore, we have developed a novel calibration system based on $γ$-ray emission by neutron capture on $^{28}$Si, $^{56}$Fe and $^{58}$Ni nuclei. In the paper, we report the development of the new calibration system as well as the results of energy calibration in CANDLES up to 9 MeV.
△ Less
Submitted 26 March, 2020;
originally announced March 2020.
-
A measurement of the scintillation decay time constant of nuclear recoils in liquid xenon with the XMASS-I detector
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
T. Suzuki,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki
, et al. (13 additional authors not shown)
Abstract:
We report an in-situ measurement of the nuclear recoil (NR) scintillation decay time constant in liquid xenon (LXe) using the XMASS-I detector at the Kamioka underground laboratory in Japan. XMASS-I is a large single-phase LXe scintillation detector whose purpose is the direct detection of dark matter via NR which can be induced by collisions between Weakly Interacting Massive Particles (WIMPs) an…
▽ More
We report an in-situ measurement of the nuclear recoil (NR) scintillation decay time constant in liquid xenon (LXe) using the XMASS-I detector at the Kamioka underground laboratory in Japan. XMASS-I is a large single-phase LXe scintillation detector whose purpose is the direct detection of dark matter via NR which can be induced by collisions between Weakly Interacting Massive Particles (WIMPs) and a xenon nucleus. The inner detector volume contains 832 kg of LXe.
$^{252}$Cf was used as an external neutron source for irradiating the detector. The scintillation decay time constant of the resulting neutron induced NR was evaluated by comparing the observed photon detection times with Monte Carlo simulations. Fits to the decay time prefer two decay time components, one for each of the Xe$_{2}^{*}$ singlet and triplet states, with $τ_{S}$ = 4.3$\pm$0.6 ns taken from prior research, $τ_{T}$ was measured to be 26.9$^{+0.7}_{-1.1}$ ns with a singlet state fraction F$_{S}$ of 0.252$^{+0.027}_{-0.019}$.We also evaluated the performance of pulse shape discrimination between NR and electron recoil (ER) with the aim of reducing the electromagnetic background in WIMP searches. For a 50\% NR acceptance, the ER acceptance was 13.7${\pm}$1.0\% and 4.1${\pm}$0.7\% in the energy ranges of 5--10 keV$_{\rm ee}$ and 10--15 keV$_{\rm ee}$, respectively.
△ Less
Submitted 24 December, 2018; v1 submitted 16 September, 2018;
originally announced September 2018.
-
Search for sub-GeV dark matter by annual modulation using XMASS-I detector
Authors:
M. Kobayashi,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
T. Suzuki,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki,
B. D. Xu,
K. Miuchi
, et al. (11 additional authors not shown)
Abstract:
A search for dark matter (DM) with mass in the sub-GeV region (0.32-1 GeV) was conducted by looking for an annual modulation signal in XMASS, a single-phase liquid xenon detector. Inelastic nuclear scattering accompanied by bremsstrahlung emission was used to search down to an electron equivalent energy of 1 keV. The data used had a live time of 2.8 years (3.5 years in calendar time), resulting in…
▽ More
A search for dark matter (DM) with mass in the sub-GeV region (0.32-1 GeV) was conducted by looking for an annual modulation signal in XMASS, a single-phase liquid xenon detector. Inelastic nuclear scattering accompanied by bremsstrahlung emission was used to search down to an electron equivalent energy of 1 keV. The data used had a live time of 2.8 years (3.5 years in calendar time), resulting in a total exposure of 2.38 ton-years. No significant modulation signal was observed and 90% confidence level upper limits of $1.6 \times 10^{-33}$ cm$^2$ at 0.5 GeV was set for the DM-nucleon cross section. This is the first experimental result of a search for DM mediated by the bremsstrahlung effect. In addition, a search for DM with mass in the multi-GeV region (4-20 GeV) was conducted with a lower energy threshold than previous analysis of XMASS. Elastic nuclear scattering was used to search down to a nuclear recoil equivalent energy of 2.3 keV, and upper limits of 2.9 $\times$10$^{-42}$ cm$^2$ at 8 GeV was obtained.
△ Less
Submitted 22 December, 2018; v1 submitted 19 August, 2018;
originally announced August 2018.
-
Development of low radioactivity photomultiplier tubes for the XMASS-I detector
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
XMASS-I is a single-phase liquid xenon detector whose purpose is direct detection of dark matter. To achieve the low background requirements necessary in the detector, a new model of photomultiplier tubes (PMTs), R10789, with a hexagonal window was developed based on the R8778 PMT used in the XMASS prototype detector. We screened the numerous component materials for their radioactivity. During dev…
▽ More
XMASS-I is a single-phase liquid xenon detector whose purpose is direct detection of dark matter. To achieve the low background requirements necessary in the detector, a new model of photomultiplier tubes (PMTs), R10789, with a hexagonal window was developed based on the R8778 PMT used in the XMASS prototype detector. We screened the numerous component materials for their radioactivity. During development, the largest contributions to the reduction of radioactivity came from the stem and the dynode support. The glass stem was exchanged to the Kovar alloy one and the ceramic support were changed to the quartz one. R10789 is the first model of Hamamatsu Photonics K. K. that adopted these materials for low background purposes and provided a groundbreaking step for further reductions of radioactivity in PMTs. Measurements with germanium detectors showed 1.2$\pm$0.3 mBq/PMT of $^{226}$Ra, less than 0.78 mBq/PMT of $^{228}$Ra, 9.1$\pm$2.2 mBq/PMT of $^{40}$K, and 2.8$\pm$0.2 mBq/PMT of $^{60}$Co. In this paper, the radioactive details of the developed R10789 are described together with our screening methods and the components of the PMT.
△ Less
Submitted 29 January, 2019; v1 submitted 10 August, 2018;
originally announced August 2018.
-
Search for dark matter in the form of hidden photons and axion-like particles in the XMASS detector
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
T. Suzuki,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki
, et al. (13 additional authors not shown)
Abstract:
Hidden photons and axion-like particles are candidates for cold dark matter if they were produced non-thermally in the early universe. We conducted a search for both of these bosons using 800 live-days of data from the XMASS detector with 327 kg of liquid xenon in the fiducial volume. No significant signal was observed, and thus we set constraints on the $α' / α$ parameter related to kinetic mixin…
▽ More
Hidden photons and axion-like particles are candidates for cold dark matter if they were produced non-thermally in the early universe. We conducted a search for both of these bosons using 800 live-days of data from the XMASS detector with 327 kg of liquid xenon in the fiducial volume. No significant signal was observed, and thus we set constraints on the $α' / α$ parameter related to kinetic mixing of hidden photons and the coupling constant $g_{Ae}$ of axion-like particles in the mass range from 40 to 120 keV/$c^2$, resulting in $α' / α< 6 \times 10^{-26}$ and $g_{Ae} < 4 \times 10^{-13}$. These limits are the most stringent derived from both direct and indirect searches to date.
△ Less
Submitted 18 November, 2018; v1 submitted 23 July, 2018;
originally announced July 2018.
-
A direct dark matter search in XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
A search for dark matter using an underground single-phase liquid xenon detector was conducted at the Kamioka Observatory in Japan, particularly for Weakly Interacting Massive Particles (WIMPs). We have used 705.9 live days of data in a fiducial volume containing 97 kg of liquid xenon at the center of the detector. The event rate in the fiducial volume after the data reduction was…
▽ More
A search for dark matter using an underground single-phase liquid xenon detector was conducted at the Kamioka Observatory in Japan, particularly for Weakly Interacting Massive Particles (WIMPs). We have used 705.9 live days of data in a fiducial volume containing 97 kg of liquid xenon at the center of the detector. The event rate in the fiducial volume after the data reduction was ${\rm (4.2 \pm 0.2) \times 10^{-3} \, day^{-1}kg^{-1} keV_{ee}^{-1}}$ at ${\rm 5 \, keV_{ee}}$, with a signal efficiency of ${\rm 20\%}$. All the remaining events are consistent with our background evaluation, mostly of the "mis-reconstructed events" originated from $^{210}$Pb in the copper plates lining the detector's inner surface. The obtained upper limit on a spin-independent WIMP-nucleon cross section was ${\rm 2.2 \times 10^{-44} \, cm^{2}}$ for a WIMP mass of ${\rm 60 \, GeV/c^{2}}$ at the $90\%$ confidence level, which was the most stringent limit among results from single-phase liquid xenon detectors.
△ Less
Submitted 25 December, 2018; v1 submitted 6 April, 2018;
originally announced April 2018.
-
Improved search for two-neutrino double electron capture on $^{124}$Xe and $^{126}$Xe using particle identification in XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
We conducted an improved search for the simultaneous capture of two $K$-shell electrons on the $^{124}$Xe and $^{126}$Xe nuclei with emission of two neutrinos using 800.0 days of data from the XMASS-I detector. A novel method to discriminate $γ$-ray/$X$-ray or double electron capture signals from $β$-ray background using scintillation time profiles was developed for this search. No significant sig…
▽ More
We conducted an improved search for the simultaneous capture of two $K$-shell electrons on the $^{124}$Xe and $^{126}$Xe nuclei with emission of two neutrinos using 800.0 days of data from the XMASS-I detector. A novel method to discriminate $γ$-ray/$X$-ray or double electron capture signals from $β$-ray background using scintillation time profiles was developed for this search. No significant signal was found when fitting the observed energy spectra with the expected signal and background. Therefore, we set the most stringent lower limits on the half-lives at $2.1 \times 10^{22}$ and $1.9 \times 10^{22}$ years for $^{124}$Xe and $^{126}$Xe, respectively, with 90% confidence level. These limits improve upon previously reported values by a factor of 4.5.
△ Less
Submitted 16 April, 2018; v1 submitted 10 January, 2018;
originally announced January 2018.
-
Search for solar Kaluza-Klein axion by annual modulation with the XMASS-I detector
Authors:
XMASS Collaboration,
N. Oka,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda
, et al. (17 additional authors not shown)
Abstract:
In theories with the large extra dimensions beyond the standard 4-dimensional spacetime, axions could propagate in such extra dimensions, and acquire Kaluza-Klein (KK) excitations. These KK axions are produced in the Sun and could solve unexplained heating of the solar corona. While most of the solar KK axions escape from the solar system, a small fraction is gravitationally trapped in orbits arou…
▽ More
In theories with the large extra dimensions beyond the standard 4-dimensional spacetime, axions could propagate in such extra dimensions, and acquire Kaluza-Klein (KK) excitations. These KK axions are produced in the Sun and could solve unexplained heating of the solar corona. While most of the solar KK axions escape from the solar system, a small fraction is gravitationally trapped in orbits around the Sun. They would decay into two photons inside a terrestrial detector. The event rate is expected to modulate annually depending on the distance from the Sun. We have searched for the annual modulation signature using $832\times 359$ kg$\cdot$days of XMASS-I data. No significant event rate modulation is found, and hence we set the first experimental constraint on the KK axion-photon coupling of $4.8 \times 10^{-12}\, \mathrm{GeV}^{-1}$ at 90% confidence level for a KK axion number density of $\bar{n}_\mathrm{a} = 4.07 \times 10^{13}\, \mathrm{m}^{-3}$, the total number of extra dimensions $n = 2$, and the number of extra dimensions $δ= 2$ that axions can propagate in.
△ Less
Submitted 15 November, 2017; v1 submitted 19 July, 2017;
originally announced July 2017.
-
Identification of $^{210}$Pb and $^{210}$Po in the bulk of copper samples with a low-background alpha particle counter
Authors:
XMASS collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
We established a method to assay $^{210}$Pb and $^{210}$Po contaminations in the bulk of copper samples using a low-background alpha particle counter. The achieved sensitivity for the $^{210}$Pb and $^{210}$Po contaminations reaches a few mBq/kg. Due to this high sensitivity, the $^{210}$Pb and $^{210}$Po contaminations in oxygen free copper bulk were identified and measured for the first time. Th…
▽ More
We established a method to assay $^{210}$Pb and $^{210}$Po contaminations in the bulk of copper samples using a low-background alpha particle counter. The achieved sensitivity for the $^{210}$Pb and $^{210}$Po contaminations reaches a few mBq/kg. Due to this high sensitivity, the $^{210}$Pb and $^{210}$Po contaminations in oxygen free copper bulk were identified and measured for the first time. The $^{210}$Pb contaminations of our oxygen free copper samples were 17-40 mBq/kg. Based on our investigation of copper samples in each production step, the $^{210}$Pb in oxygen free copper was understood to be a small residual of an electrolysis process. This method to measure bulk contaminations of $^{210}$Pb and $^{210}$Po could be applied to other materials.
△ Less
Submitted 9 January, 2018; v1 submitted 20 July, 2017;
originally announced July 2017.
-
Search for cosmic dark matter by means of ultra high purity NaI(Tl) scintillator
Authors:
K. Fushimi,
D. Chernyak,
H. Ejiri,
R. Hazama,
S. Hirata,
H. Ikeda,
K. Inoue,
K. Imagawa,
G. Kanzaki,
A. Kozlov,
R. Orito,
T. Shima,
Y. Takemoto,
Y. Teraoka,
S. Umehara,
S. Yoshida
Abstract:
The dark matter search project by means of ultra high purity NaI(Tl) scintillator is now underdevelopment. An array of large volume NaI(Tl) detectors whose volume is 12.7 cm$φ\times$12.7 cm is applied to search for dark matter signal. To remove radioactive impurities in NaI(Tl) crystal is one of the most important task to find small number of dark matter signals. We have developed high purity NaI(…
▽ More
The dark matter search project by means of ultra high purity NaI(Tl) scintillator is now underdevelopment. An array of large volume NaI(Tl) detectors whose volume is 12.7 cm$φ\times$12.7 cm is applied to search for dark matter signal. To remove radioactive impurities in NaI(Tl) crystal is one of the most important task to find small number of dark matter signals. We have developed high purity NaI(Tl) crystal which contains small amounts of radioactive impurities, $<4$ ppb of $^{nat}$K, 0.3 ppt of Th chain, 58 $μ$Bq/kg of $^{226}$Ra and 30 $μ$Bq/kg of $^{210}$Pb. Future prospects to search for dark matter by means of a large volume and high purity NaI(Tl) scintillator is discussed.
△ Less
Submitted 28 April, 2017;
originally announced May 2017.
-
High purity NaI(Tl) scintillator to search for dark matter
Authors:
Ken-Ichi Fushimi,
Hiroyasu Ejiri,
Ryuta Hazama,
Haruo Ikeda,
Kunio Inoue,
Kyoshiro Imagawa,
Gakuji Kanzaki,
Alexandre Kozlov,
Reiko Orito,
Tatsushi Shima,
Yasuhiro Takemoto,
Yuri Teraoka,
Saori Umehara,
Sei Yoshida
Abstract:
A high purity and large volume NaI(Tl) scintillator was developed to search for cosmic dark matter. The required densities of radioactive impurities (RIs) such as U-chain, Th-chain are less than a few ppt to establish high sensitivity to dark matter. The impurity of RIs were effectively reduced by selecting raw materials of crucible and by performing chemical reduction of lead ion in NaI raw powde…
▽ More
A high purity and large volume NaI(Tl) scintillator was developed to search for cosmic dark matter. The required densities of radioactive impurities (RIs) such as U-chain, Th-chain are less than a few ppt to establish high sensitivity to dark matter. The impurity of RIs were effectively reduced by selecting raw materials of crucible and by performing chemical reduction of lead ion in NaI raw powder. The impurity of $^{226}$Ra was reduced less than 100 $μ$Bq/kg in NaI(Tl) crystal. It should be remarked that the impurity of $^{210}$Pb, which is difficult to reduce, is effectively reduced by chemical processing of NaI raw powder down to less than 30 $μ$Bq/kg. The expected sensitivity to cosmic dark matter by using 250 kg of the high purity and large volume NaI(Tl) scintillator (PICO-LON; Pure Inorganic Crystal Observatory for LOw-background Neutr(al)ino) is 7$\times$10$^{-45}$ cm$^{2}$ for 50 GeV$/c^{2}$ WIMPs.
△ Less
Submitted 16 May, 2016;
originally announced May 2016.
-
A measurement of the time profile of scintillation induced by low energy gamma-rays in liquid xenon with the XMASS-I detector
Authors:
XMASS Collaboration,
H. Takiya,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
R. Kegasa,
K. Kobayashi,
K. Masuda,
K. Fushimi
, et al. (15 additional authors not shown)
Abstract:
We report the measurement of the emission time profile of scintillation from gamma-ray induced events in the XMASS-I 832 kg liquid xenon scintillation detector. Decay time constant was derived from a comparison of scintillation photon timing distributions between the observed data and simulated samples in order to take into account optical processes such as absorption and scattering in liquid xeno…
▽ More
We report the measurement of the emission time profile of scintillation from gamma-ray induced events in the XMASS-I 832 kg liquid xenon scintillation detector. Decay time constant was derived from a comparison of scintillation photon timing distributions between the observed data and simulated samples in order to take into account optical processes such as absorption and scattering in liquid xenon. Calibration data of radioactive sources, $^{55}$Fe, $^{241}$Am, and $^{57}$Co were used to obtain the decay time constant. Assuming two decay components, $τ_1$ and $τ_2$, the decay time constant $τ_2$ increased from 27.9 ns to 37.0 ns as the gamma-ray energy increased from 5.9 keV to 122 keV. The accuracy of the measurement was better than 1.5 ns at all energy levels. A fast decay component with $τ_1 \sim 2$ ns was necessary to reproduce data. Energy dependencies of $τ_2$ and the fraction of the fast decay component were studied as a function of the kinetic energy of electrons induced by gamma-rays. The obtained data almost reproduced previously reported results and extended them to the lower energy region relevant to direct dark matter searches.
△ Less
Submitted 18 August, 2016; v1 submitted 6 April, 2016;
originally announced April 2016.
-
Dark matter search project PICO-LON
Authors:
K. Fushimi,
H. Ejiri,
R. Hazama,
H. Ikeda,
K. Imagawa,
K. Inoue,
G. Kanzaki,
A. Kozlov,
R. Orito,
T. Shima,
Y. Takemoto,
Y. Teraoka,
S. Umehara,
K. Yasuda,
S. Yoshida
Abstract:
The PICO-LON project aims at search for cold dark matter by means of highly radio-pure and large volume NaI(Tl) scintillator. The NaI powder was purifed by chemical processing to remove lead isotopes and selecting a high purity graphite crucible. The concentrations of radioactive impurities of $^{226}$Ra and $^{228}$Th were effectively reduced to 58$\pm$4 $μ$Bq/kg and 1.5$\pm$1.9 $μ$Bq/kg, respect…
▽ More
The PICO-LON project aims at search for cold dark matter by means of highly radio-pure and large volume NaI(Tl) scintillator. The NaI powder was purifed by chemical processing to remove lead isotopes and selecting a high purity graphite crucible. The concentrations of radioactive impurities of $^{226}$Ra and $^{228}$Th were effectively reduced to 58$\pm$4 $μ$Bq/kg and 1.5$\pm$1.9 $μ$Bq/kg, respectively. It should be remarked that the concentration of $^{210}$Pb, which is crucial for the sensitivity to dark matter, was reduced to 24$\pm$2 $μ$Bq/kg. The total background rate at 10 keVee was as low as 8 keV$^{-1}$kg$^{-1}$day$^{-1}$, which was sufficiently low to search for dark matter. Further purification of NaI(Tl) ingot and future prospect of PICO-LON project is discussed.
△ Less
Submitted 14 December, 2015;
originally announced December 2015.
-
Direct dark matter search by annual modulation in XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
H. Sekiya,
O. Takachio,
A. Takeda,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
S. Tasaka,
K. Fushimi,
J. Liu,
K. Martens,
Y. Suzuki,
B. D. Xu,
R. Fujita
, et al. (17 additional authors not shown)
Abstract:
A search for dark matter was conducted by looking for an annual modulation signal due to the Earth's rotation around the Sun using XMASS, a single phase liquid xenon detector. The data used for this analysis was 359.2 live days times 832 kg of exposure accumulated between November 2013 and March 2015. When we assume Weakly Interacting Massive Particle (WIMP) dark matter elastically scattering on t…
▽ More
A search for dark matter was conducted by looking for an annual modulation signal due to the Earth's rotation around the Sun using XMASS, a single phase liquid xenon detector. The data used for this analysis was 359.2 live days times 832 kg of exposure accumulated between November 2013 and March 2015. When we assume Weakly Interacting Massive Particle (WIMP) dark matter elastically scattering on the target nuclei, the exclusion upper limit of the WIMP-nucleon cross section 4.3$\times$10$^{-41}$cm$^2$ at 8 GeV/c$^2$ was obtained and we exclude almost all the DAMA/LIBRA allowed region in the 6 to 16 GeV/c$^2$ range at $\sim$10$^{-40}$cm$^2$. The result of a simple modulation analysis, without assuming any specific dark matter model but including electron/$γ$ events, showed a slight negative amplitude. The $p$-values obtained with two independent analyses are 0.014 and 0.068 for null hypothesis, respectively. we obtained 90\% C.L. upper bounds that can be used to test various models. This is the first extensive annual modulation search probing this region with an exposure comparable to DAMA/LIBRA.
△ Less
Submitted 25 May, 2016; v1 submitted 15 November, 2015;
originally announced November 2015.
-
Search for double-beta decay of 136Xe to excited states of 136Ba with the KamLAND-Zen experiment
Authors:
KamLAND-Zen Collaboration,
:,
K. Asakura,
A. Gando,
Y. Gando,
T. Hachiya,
S. Hayashida,
H. Ikeda,
K. Inoue,
K. Ishidoshiro,
T. Ishikawa,
S. Ishio,
M. Koga,
S. Matsuda,
T. Mitsui,
D. Motoki,
K. Nakamura,
S. Obara,
M. Otani,
T. Oura,
I. Shimizu,
Y. Shirahata,
J. Shirai,
A. Suzuki,
H. Tachibana
, et al. (21 additional authors not shown)
Abstract:
A search for double-beta decays of 136Xe to excited states of 136Ba has been performed with the first phase data set of the KamLAND-Zen experiment. The 0+1, 2+1 and 2+2 transitions of 0ν\{beta}\{beta} decay were evaluated in an exposure of 89.5kg-yr of 136Xe, while the same transitions of 2ν\{beta}\{beta} decay were evaluated in an exposure of 61.8kg-yr. No excess over background was found for all…
▽ More
A search for double-beta decays of 136Xe to excited states of 136Ba has been performed with the first phase data set of the KamLAND-Zen experiment. The 0+1, 2+1 and 2+2 transitions of 0ν\{beta}\{beta} decay were evaluated in an exposure of 89.5kg-yr of 136Xe, while the same transitions of 2ν\{beta}\{beta} decay were evaluated in an exposure of 61.8kg-yr. No excess over background was found for all decay modes. The lower half-life limits of the 2+1 state transitions of 0ν\{beta}\{beta} and 2ν\{beta}\{beta} decay were improved to T(0ν, 0+ \rightarrow 2+) > 2.6\times10^25 yr and T(2ν, 0+ \rightarrow 2+) > 4.6\times10^23 yr (90% C.L.), respectively. We report on the first experimental lower half-life limits for the transitions to the 0+1 state of 136Xe for 0ν\{beta}\{beta} and 2ν\{beta}\{beta} decay. They are T (0ν, 0+ \rightarrow 0+) > 2.4\times10^25 yr and T(2ν, 0+ \rightarrow 0+) > 8.3\times10^23 yr (90% C.L.). The transitions to the 2+2 states are also evaluated for the first time to be T(0ν, 0+ \rightarrow 2+) > 2.6\times10^25 yr and T(2ν, 0+ \rightarrow 2+) > 9.0\times10^23 yr (90% C.L.). These results are compared to recent theoretical predictions.
△ Less
Submitted 8 December, 2015; v1 submitted 12 September, 2015;
originally announced September 2015.
-
KamLAND Sensitivity to Neutrinos from Pre-Supernova Stars
Authors:
K. Asakura,
A. Gando,
Y. Gando,
T. Hachiya,
S. Hayashida,
H. Ikeda,
K. Inoue,
K. Ishidoshiro,
T. Ishikawa,
S. Ishio,
M. Koga,
S. Matsuda,
T. Mitsui,
D. Motoki,
K. Nakamura,
S. Obara,
T. Oura,
I. Shimizu,
Y. Shirahata,
J. Shirai,
A. Suzuki,
H. Tachibana,
K. Tamae,
K. Ueshima,
H. Watanabe
, et al. (22 additional authors not shown)
Abstract:
In the late stages of nuclear burning for massive stars ($M>8~M_{\sun}$), the production of neutrino-antineutrino pairs through various processes becomes the dominant stellar cooling mechanism. As the star evolves, the energy of these neutrinos increases and in the days preceding the supernova a significant fraction of emitted electron anti-neutrinos exceeds the energy threshold for inverse beta d…
▽ More
In the late stages of nuclear burning for massive stars ($M>8~M_{\sun}$), the production of neutrino-antineutrino pairs through various processes becomes the dominant stellar cooling mechanism. As the star evolves, the energy of these neutrinos increases and in the days preceding the supernova a significant fraction of emitted electron anti-neutrinos exceeds the energy threshold for inverse beta decay on free hydrogen. This is the golden channel for liquid scintillator detectors because the coincidence signature allows for significant reductions in background signals. We find that the kiloton-scale liquid scintillator detector KamLAND can detect these pre-supernova neutrinos from a star with a mass of $25~M_{\sun}$ at a distance less than 690~pc with 3$σ$ significance before the supernova. This limit is dependent on the neutrino mass ordering and background levels. KamLAND takes data continuously and can provide a supernova alert to the community.
△ Less
Submitted 22 January, 2016; v1 submitted 3 June, 2015;
originally announced June 2015.
-
KamLAND-PICO project to search for cosmic dark matter
Authors:
K. Fushimi,
Y. Awatani,
H. Ejiri,
R. Hazama,
H. Ikeda,
K. Imagawa,
K. Inoue,
A. Kozlov,
R. Orito,
T. Shima,
R. Sugawaraand K. Yasuda
Abstract:
KamLAND-PICO project aims to search for WIMPs dark matter by means of NaI(Tl) scintillator. To investigate the WIMPs candidate whose cross section is as small as $10^{-9}$ pb, a pure NaI(Tl) crystal was developed by chemical processing and taking care of surroundings. The concentration of U and Th chain was reduced to $5.4\pm0.9$ ppt and $3.3\pm2.2$ ppt, respectively. It should be remarked that th…
▽ More
KamLAND-PICO project aims to search for WIMPs dark matter by means of NaI(Tl) scintillator. To investigate the WIMPs candidate whose cross section is as small as $10^{-9}$ pb, a pure NaI(Tl) crystal was developed by chemical processing and taking care of surroundings. The concentration of U and Th chain was reduced to $5.4\pm0.9$ ppt and $3.3\pm2.2$ ppt, respectively. It should be remarked that the concentration of $^{210}$Pb which was difficult to reduce reached to the high purity as $58\pm26$ $μ$Bq/kg.
△ Less
Submitted 14 July, 2014;
originally announced July 2014.
-
The Performance of the Thin NaI(Tl) Detector Pico-Lon for Dark Matter Search
Authors:
K. Harada,
K. Fushimi,
S. Nakayama,
R. Orito,
S. Iida,
S. Ito,
H. Ejiri,
T. Shima,
R. Hazama,
E. Matsumoto,
H. Ito,
K. Imagawa
Abstract:
Thin and large area NaI(Tl) scintillator to search for WIMPs dark matter was developed. The performance of thin and wide area NaI(Tl) showed good enough to search for dark matter. The energy threshold was as low as 2keV and the energy resolution was about 24% in FWHM at 60keV.
Thin and large area NaI(Tl) scintillator to search for WIMPs dark matter was developed. The performance of thin and wide area NaI(Tl) showed good enough to search for dark matter. The energy threshold was as low as 2keV and the energy resolution was about 24% in FWHM at 60keV.
△ Less
Submitted 5 June, 2014; v1 submitted 21 March, 2012;
originally announced March 2012.
-
Spectral modeling of scintillator for the NEMO-3 and SuperNEMO detectors
Authors:
J. Argyriades,
R. Arnold,
C. Augier,
J. Baker,
A. S. Barabash,
M. Bongrand,
G. Broudin-Bay,
V. B. Brudanin,
A. J. Caffrey,
S. Cebrián,
A. Chapon,
E. Chauveau,
Th. Dafni,
Z. Daraktchieva,
J. D iaz,
D. Durand,
V. G. Egorov,
J. J. Evans,
N. Fatemi-Ghomi,
R. Flack,
A. Basharina-Freshville,
K-I. Fushimi,
X. Garrido,
H. Gómez,
B. Guillon
, et al. (68 additional authors not shown)
Abstract:
We have constructed a GEANT4-based detailed software model of photon transport in plastic scintillator blocks and have used it to study the NEMO-3 and SuperNEMO calorimeters employed in experiments designed to search for neutrinoless double beta decay. We compare our simulations to measurements using conversion electrons from a calibration source of $\rm ^{207}Bi$ and show that the agreement is im…
▽ More
We have constructed a GEANT4-based detailed software model of photon transport in plastic scintillator blocks and have used it to study the NEMO-3 and SuperNEMO calorimeters employed in experiments designed to search for neutrinoless double beta decay. We compare our simulations to measurements using conversion electrons from a calibration source of $\rm ^{207}Bi$ and show that the agreement is improved if wavelength-dependent properties of the calorimeter are taken into account. In this article, we briefly describe our modeling approach and results of our studies.
△ Less
Submitted 8 November, 2010; v1 submitted 21 April, 2010;
originally announced April 2010.