Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content

Showing 1–25 of 25 results for author: Guéna, J

Searching in archive physics. Search in all archives.
.
  1. Direct comparisons of European primary and secondary frequency standards via satellite techniques

    Authors: F. Riedel, A. Al-Masoudi, E. Benkler, S. Dörscher, V. Gerginov, C. Grebing, S. Häfner, N. Huntemann, B. Lipphardt, C. Lisdat, E. Peik, D. Piester, C. Sanner, C. Tamm, S. Weyers, H. Denker, L. Timmen, C. Voigt, D. Calonico, G. Cerretto, G. A. Costanzo, F. Levi, I. Sesia, J. Achkar, J. Guèna , et al. (24 additional authors not shown)

    Abstract: We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taki… ▽ More

    Submitted 9 October, 2019; originally announced October 2019.

  2. New measurement of the $1S-3S$ transition frequency of hydrogen: contribution to the proton charge radius puzzle

    Authors: Hélène Fleurbaey, Sandrine Galtier, Simon Thomas, Marie Bonnaud, Lucile Julien, François Biraben, François Nez, Michel Abgrall, Jocelyne Guéna

    Abstract: We present a new measurement of the $1S-3S$ two-photon transition frequency of hydrogen, realized with a continuous-wave excitation laser at 205 nm on a room-temperature atomic beam, with a relative uncertainty of $9\times10^{-13}$. The proton charge radius deduced from this measurement, $r_\text{p}=0.877(13)$ fm, is in very good agreement with the current CODATA-recommended value. This result con… ▽ More

    Submitted 27 April, 2018; v1 submitted 26 January, 2018; originally announced January 2018.

    Comments: 5 pages, 4 figures, accepted for publication by Phys. Rev. Lett

    Journal ref: Phys. Rev. Lett. 120, 183001 (2018)

  3. arXiv:1703.02892  [pdf, other

    physics.atom-ph physics.ins-det

    First international comparison of fountain primary frequency standards via a long distance optical fiber link

    Authors: J. Guéna, S. Weyers, M. Abgrall, C. Grebing, V. Gerginov, P. Rosenbusch, S. Bize, B. Lipphardt, H. Denker, N. Quintin, S. M. F. Raupach, D. Nicolodi, F. Stefani, N. Chiodo, S. Koke, A. Kuhl, F. Wiotte, F. Meynadier, E. Camisard, C. Chardonnet, Y. Le Coq, M. Lours, G. Santarelli, A. Amy-Klein, R. Le Targat , et al. (3 additional authors not shown)

    Abstract: We report on the first comparison of distant caesium fountain primary frequency standards (PFSs) via an optical fiber link. The 1415 km long optical link connects two PFSs at LNE-SYRTE (Laboratoire National de métrologie et d'Essais - SYstème de Références Temps-Espace) in Paris (France) with two at PTB (Physikalisch-Technische Bundesanstalt) in Braunschweig (Germany). For a long time, these PFSs… ▽ More

    Submitted 14 March, 2017; v1 submitted 2 March, 2017; originally announced March 2017.

    Journal ref: Metrologia 54 (2017) 348

  4. Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock

    Authors: Jérôme Lodewyck, Sławomir Bilicki, Eva Bookjans, Jean-Luc Robyr, Chunyan Shi, Grégoire Vallet, Rodolphe Le Targat, Daniele Nicolodi, Yann Le Coq, Jocelyne Guéna, Michel Abgrall, Peter Rosenbusch, Sébastien Bize

    Abstract: Optical lattice clocks are at the forefront of frequency metrology. Both the instability and systematic uncertainty of these clocks have been reported to be two orders of magnitude smaller than the best microwave clocks. For this reason, a redefinition of the SI second based on optical clocks seems possible in the near future. However, the operation of optical lattice clocks has not yet reached th… ▽ More

    Submitted 12 May, 2016; originally announced May 2016.

    Journal ref: Metrologia 53, 1123 (2016)

  5. arXiv:1604.08514  [pdf, other

    gr-qc hep-ph physics.atom-ph

    Searching for an oscillating massive scalar field as a dark matter candidate using atomic hyperfine frequency comparisons

    Authors: A. Hees, J. Guéna, M. Abgrall, S. Bize, P. Wolf

    Abstract: We use six years of accurate hyperfine frequency comparison data of the dual rubidium and caesium cold atom fountain FO2 at LNE-SYRTE to search for a massive scalar dark matter candidate. Such a scalar field can induce harmonic variations of the fine structure constant, of the mass of fermions and of the quantum chromodynamic mass scale, which will directly impact the rubidium/caesium hyperfine tr… ▽ More

    Submitted 28 July, 2016; v1 submitted 28 April, 2016; originally announced April 2016.

    Comments: 5 pages (+2 pages of supplemental material), 4 figures, version accepted for publication in Phys. Rev. Letters

    Journal ref: Phys. Rev. Lett. 117, 061301 (2016)

  6. arXiv:1603.02026  [pdf, ps, other

    physics.atom-ph physics.optics quant-ph

    Comparing a mercury optical lattice clock with microwave and optical frequency standards

    Authors: R Tyumenev, M Favier, S Bilicki, E Bookjans, R Le Targat, J Lodewyck, D Nicolodi, Y Le Coq, M Abgrall, J Guéna, L De Sarlo, S Bize

    Abstract: In this paper we report the evaluation of an optical lattice clock based on neutral mercury down to a relative uncertainty of $1.7\times 10^{-16}$. Comparing this characterized frequency standard to a Cs atomic fountain we determine the absolute frequency of the $^1S_0 \rightarrow \phantom{}^3P_0$ transition of $^{199}$Hg as $ν_{\mathrm{Hg}} = 1 128\,575\,290\,808\,154.62\,$Hz $\pm\,0.19\,$Hz (sta… ▽ More

    Submitted 13 November, 2016; v1 submitted 7 March, 2016; originally announced March 2016.

    Comments: 23 pages, 12 figures, updated version including journal reference

    Journal ref: New Journal of Physics, 18 113002 (2016)

  7. arXiv:1507.04623  [pdf, other

    physics.atom-ph physics.optics

    Atomic fountains and optical clocks at SYRTE: status and perspectives

    Authors: M. Abgrall, B. Chupin, L. De Sarlo, J. Guéna, Ph. Laurent, Y. Le Coq, R. Le Targat, J. Lodewyck, M. Lours, P. Rosenbusch, D. Rovera, S. Bize

    Abstract: In this article, we report on the work done with the LNE-SYRTE atomic clock ensemble during the last 10 years. We cover progress made in atomic fountains and in their application to timekeeping. We also cover the development of optical lattice clocks based on strontium and on mercury. We report on tests of fundamental physical laws made with these highly accurate atomic clocks. We also report on w… ▽ More

    Submitted 16 July, 2015; originally announced July 2015.

    Journal ref: Comptes Rendus Physique Volume 16, Issue 5, June 2015, Pages 461 to 470

  8. Contributing to TAI with a Secondary Representation of the SI Second

    Authors: Jocelyne Guéna, Michel Abgrall, André Clairon, Sébastien Bize

    Abstract: We report the first contribution to the international atomic time (TAI) based on a secondary representation of the SI second. This work is done with the LNE-SYRTE FO2-Rb fountain frequency standard using the $^{87}$Rb ground state hyperfine transition. We describe FO2-Rb and how it is connected to local and international time scales. We report on local measurements of this frequency standard in th… ▽ More

    Submitted 29 January, 2014; originally announced January 2014.

    Comments: 13 pages, 10 figures, 3 tables, 80 references

    Journal ref: Metrologia 51, 108 (2014)

  9. arXiv:1301.6046  [pdf

    physics.atom-ph physics.optics quant-ph

    Experimenting an optical second with strontium lattice clocks

    Authors: R. Le Targat, L. Lorini, Y. Le Coq, M. Zawada, J. Guéna, M. Abgrall, M. Gurov, P. Rosenbusch, D. G. Rovera, B. Nagórny, R. Gartman, P. G. Westergaard, M. E. Tobar, M. Lours, G. Santarelli, A. Clairon, S. Bize, P. Laurent, P. Lemonde, J. Lodewyck

    Abstract: Progress in realizing the SI second had multiple technological impacts and enabled to further constraint theoretical models in fundamental physics. Caesium microwave fountains, realizing best the second according to its current definition with a relative uncertainty of 2-4x10^(-16), have already been superseded by atomic clocks referenced to an optical transition, both more stable and more accurat… ▽ More

    Submitted 31 July, 2013; v1 submitted 25 January, 2013; originally announced January 2013.

    Comments: 9 pages, 4 figures, 2 tables

    Journal ref: Nature Communication 4, 2109 (July 2013)

  10. arXiv:1301.0483  [pdf, other

    physics.atom-ph quant-ph

    Demonstration of a Dual Alkali Rb/Cs Atomic Fountain Clock

    Authors: J. Guéna, P. Rosenbusch, Ph. Laurent, M. Abgrall, D. Rovera, M. Lours, G. Santarelli, M. E. Tobar, S. Bize, A. Clairon

    Abstract: We report the operation of a dual Rb/Cs atomic fountain clock. 133Cs and 87Rb atoms are cooled, launched, and detected simultaneously in LNE-SYRTE's FO2 double fountain. The dual clock operation occurs with no degradation of either the stability or the accuracy. We describe the key features for achieving such a simultaneous operation. We also report on the results of the first Rb/Cs frequency meas… ▽ More

    Submitted 3 January, 2013; originally announced January 2013.

    Comments: 6 pages, 10 figures, 23 references

    Journal ref: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control 57, 647 (2010)

  11. Improved tests of Local Position Invariance using 87Rb and 133Cs fountains

    Authors: Jocelyne Guéna, Michel Abgrall, Daniele Rovera, Peter Rosenbusch, Michael E. Tobar, Philippe Laurent, André Clairon, Sébastien Bize

    Abstract: We report tests of local position invariance based on measurements of the ratio of the ground state hyperfine frequencies of 133Cs and 87Rb in laser-cooled atomic fountain clocks. Measurements extending over 14 years set a stringent limit to a possible variation with time of this ratio: d ln(nu_Rb/nu_Cs)/dt=(-1.39 +/- 0.91)x 10-16 yr-1. This improves by a factor of 7.7 over our previous report (H.… ▽ More

    Submitted 22 August, 2012; v1 submitted 18 May, 2012; originally announced May 2012.

    Comments: 5 pages, 3 figures, 3 tables, 34 references

    Journal ref: Phys. Rev. Lett. 109, 080801 (2012)

  12. Progress in Atomic Fountains at LNE-SYRTE

    Authors: Jocelyne Guéna, Michel Abgrall, Daniele Rovera, Philippe Laurent, Baptiste Chupin, Michel Lours, Giorgio Santarelli, Peter Rosenbusch, Michael E. Tobar, Ruoxin Li, Kurt Gibble, André Clairon, Sébastien Bize

    Abstract: We give an overview of the work done with the Laboratoire National de Métrologie et d'Essais-Systèmes de Référence Temps-Espace (LNE-SYRTE) fountain ensemble during the last five years. After a description of the clock ensemble, comprising three fountains, FO1, FO2, and FOM, and the newest developments, we review recent studies of several systematic frequency shifts. This includes the distributed… ▽ More

    Submitted 16 April, 2012; originally announced April 2012.

    Comments: 19 pages, 12 figures, 5 tables, 126 references

    Journal ref: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol. 59, pages 391-420 (2012)

  13. A neutral atom frequency reference in the deep UV with 10^(-15) range uncertainty

    Authors: J. J. McFerran, L. Yi, S. Mejri, S. Di Manno, W. Zhang, J. Guéna, Y. Le Coq, S. Bize

    Abstract: We present an assessment of the (6s^{2})1S0 -> (6s7s)3P0 clock transition frequency in 199Hg with an uncertainty reduction of nearly three orders of magnitude and demonstrate an atomic quality factor, Q, of ~10^(14). The 199Hg atoms are confined in a vertical lattice trap with light at the newly determined magic wavelength of 362.5697 +/-0.0011 nm and at a lattice depth of 20Er. The atoms are load… ▽ More

    Submitted 17 January, 2012; originally announced January 2012.

    Comments: 5 pages, 6 figures

    Journal ref: Phys. Rev. Lett. 108, 183004 (2012)

  14. arXiv:1103.1633  [pdf

    quant-ph physics.atom-ph

    Evaluation of Doppler Shifts to Improve the Accuracy of Primary Atomic Fountain Clocks

    Authors: Jocelyne Guéna, Ruoxin Li, Kurt Gibble, Sébastien Bize, André Clairon

    Abstract: We demonstrate agreement between measurements and ab initio calculations of the frequency shifts caused by distributed cavity phase variations in the microwave cavity of a primary atomic fountain clock. Experimental verification of the finite element models of the cavities gives the first quantitative evaluation of this leading uncertainty and allows it to be reduced to delta nu / nu = 8.4\times10… ▽ More

    Submitted 8 March, 2011; originally announced March 2011.

    Comments: To appear in PRL

    Journal ref: Phys. Rev. Lett. 106, 130801 (2011)

  15. arXiv:0901.3654  [pdf, ps, other

    physics.atom-ph physics.optics

    Ultra-low noise microwave generation with fiber-based optical frequency comb and application to atomic fountain clock

    Authors: J. Millo, M. Abgrall, M. Lours, E. M. L. English, H. Jiang, J. Guena, A. Clairon, S. Bize, Y. Le Coq, G. Santarelli, M. E. Tobar

    Abstract: We demonstrate the use of a fiber-based femtosecond laser locked onto an ultra-stable optical cavity to generate a low-noise microwave reference signal. Comparison with both a liquid Helium cryogenic sapphire oscillator (CSO) and a Ti:Sapphire-based optical frequency comb system exhibit a stability about $3\times10^{-15}$ between 1 s and 10 s. The microwave signal from the fiber system is used t… ▽ More

    Submitted 23 January, 2009; originally announced January 2009.

    Comments: 3 pages, 3 figures

    Journal ref: Applied Physics Letters, 94, 141105 (2009)

  16. arXiv:physics/0702164  [pdf, ps, other

    physics.atom-ph physics.ins-det

    An experimental study of intermodulation effects in an atomic fountain frequency standard

    Authors: Jocelyne Guéna, Gregor Dudle, Pierre Thomann

    Abstract: The short-term stability of passive atomic frequency standards, especially in pulsed operation, is often limited by local oscillator noise via intermodulation effects. We present an experimental demonstration of the intermodulation effect on the frequency stability of a continuous atomic fountain clock where, under normal operating conditions, it is usually too small to observe. To achieve this,… ▽ More

    Submitted 20 February, 2007; originally announced February 2007.

    Journal ref: European Physical Journal Applied Physics, 388 (30/05/2007) 183-189

  17. arXiv:physics/0610035  [pdf, ps, other

    physics.atom-ph physics.gen-ph

    Pump-probe measurement of atomic parity violation in caesium with a precision of 2.6%

    Authors: Michel Lintz, Jocelyne Guéna, Marie-Anne Bouchiat

    Abstract: We present the atomic parity violation measurements made in Cs vapour using a pump-probe scheme. After pulsed excitation of the 6S-7S forbidden transition in the presence of a longitudinal electric field, a laser beam resonant with one of the 7S-6P transitions stimulates the 7S atom emission for a duration of 20 ns. The polarisation of the amplified probe beam is analysed. A seven-fold signature… ▽ More

    Submitted 6 October, 2006; originally announced October 2006.

    Comments: "conference PAVI 06, Milos, Greece, May 2006"

    Journal ref: European Physical Journal A 32, 4 (25/07/2007) 525-529

  18. arXiv:physics/0504020  [pdf

    physics.ins-det

    An Alkali-Vapor Cell with Metal Coated Windows for Efficient Application of an Electric Field

    Authors: David Sarkisyan, A. S. Sarkisyan, Jocelyne Guéna, Michel Lintz, Marie-Anne Bouchiat

    Abstract: We describe the implementation of a cylindrical T-shaped alkali-vapor cell for laser spectroscopy in the presence of a longitudinal electric field. The two windows are used as two electrodes of the high-voltage assembly, which is made possible by a metallic coating which entirely covers the inner and outer sides of the windows except for a central area to let the laser beams in and out of the ce… ▽ More

    Submitted 4 April, 2005; originally announced April 2005.

    Journal ref: Review of Scientific Instruments 76 (2005) 053108

  19. arXiv:physics/0503143  [pdf, ps, other

    physics.atom-ph physics.gen-ph

    Atomic Parity Violation : Principles, Recent Results, Present Motivations

    Authors: Jocelyne Guéna, Michel Lintz, Marie-Anne Bouchiat

    Abstract: We review the progress made in the determination of the weak charge, Q\_w, of the cesium nucleus which raises the status of Atomic Parity Violation measurements to that of a precision electroweak test. Not only is it necessary to have a precision measurement of the electroweak asymmetry in the highly forbidden 6S-7S transition, but one also needs a precise calibration procedure. The 1999 precisi… ▽ More

    Submitted 17 March, 2005; originally announced March 2005.

    Journal ref: Mod.Phys.Lett. A20 (2005) 375-390

  20. arXiv:physics/0412017  [pdf, ps, other

    physics.atom-ph hep-ph

    Measurement of the parity violating 6S-7S transition amplitude in cesium achieved within 2 \times 10^{-13} atomic-unit accuracy by stimulated-emission detection

    Authors: J. Guéna, M. Lintz, M. -A. Bouchiat

    Abstract: We exploit the process of asymmetry amplification by stimulated emission which provides an original method for parity violation (PV) measurements in a highly forbidden atomic transition. The method involves measurements of a chiral, transient, optical gain of a cesium vapor on the 7S-6P_{3/2} transition, probed after it is excited by an intense, linearly polarized, collinear laser, tuned to reso… ▽ More

    Submitted 4 March, 2005; v1 submitted 2 December, 2004; originally announced December 2004.

    Comments: Article 21 pages, 6 figures, 3 tables Typos, addition of few comments and little more data (1 week) leading to a slight reduction of the error bar Accepted for publication in Phys.Rev. A

  21. arXiv:physics/0410044  [pdf

    physics.optics

    Demonstration of an optical polarization magnifier with low birefringence

    Authors: Michel Lintz, Jocelyne Guena, Marie-Anne Bouchiat, Dominique Chauvat

    Abstract: In any polarimetric measurement technique, enhancing the laser polarization change of a laser beam before it reaches the analyzer can help in improving the sensitivity. This can be performed using an optical component having a large linear dichroism, the enhancement factor being equal to the square root of the ratio of the two transmission factors. A pile of parallel plates at Brewster incidence… ▽ More

    Submitted 22 March, 2005; v1 submitted 7 October, 2004; originally announced October 2004.

    Comments: 08 october 2004

    Journal ref: Review of Scientific Instruments 76 (2005) 043102

  22. Proposal for high-precision Atomic Parity Violation measurements using amplification of the asymmetry by stimulated emission in a transverse E and B field pump-probe experiment

    Authors: J. Guéna, M. Lintz, M. A Bouchiat

    Abstract: Amplification by stimulated emission of radiation provides an intriguing means for increasing the sensitivity of Atomic Parity Violation (APV) measurements in a pump-probe configuration well adapted to the 6S-7S cesium transition. It takes advantage of the large number of atoms excited along the path of the pump beam. In the longitudinal E-field configuration currently exploited in an ongoing AP… ▽ More

    Submitted 30 March, 2004; originally announced March 2004.

    Comments: Article

  23. Cylindrical Symmetry Discrimination of Magnetoelectric Optical Systematic Effects in a Pump-probe Atomic Parity Violation Experiment

    Authors: M-A. Bouchiat, J. Guéna, M. Lintz

    Abstract: A pump-probe atomic parity violation (APV) experiment performed in a longitudinal electric field, provides a signal breaking mirror symmetry while preserving the cylindrical symmetry of the set-up. The excited vapor acts on the probe beam as a linear dichroic amplifier, imprinting a very specific signature on the detected signal. Our differential polarimeter is oriented to yield a null result un… ▽ More

    Submitted 20 November, 2003; originally announced November 2003.

    Comments: Article

  24. Prospects for Forbidden-Transition Spectroscopy and Parity Violation Measurements using a Beam of Cold Stable or Radioactive Atoms

    Authors: S. Sanguinetti, J. Guéna, M. Lintz, Ph. Jacquier, A. Wasan, M-A. Bouchiat

    Abstract: Laser cooling and trapping offers the possibility of confining a sample of radioactive atoms in free space. Here, we address the question of how best to take advantage of cold atom properties to perform the observation of as highly forbidden a line as the 6S-7S Cs transition for achieving, in the longer term, Atomic Parity Violation measurements in radioactive alkali isotopes. Another point at i… ▽ More

    Submitted 2 March, 2003; originally announced March 2003.

    Comments: 13 pages, 4 figures, 1 table

  25. arXiv:physics/0210069  [pdf, ps, other

    physics.atom-ph physics.gen-ph

    A new Manifestation of Atomic Parity Violation in Cesium: a Chiral Optical Gain induced by linearly polarized 6S-7S Excitation

    Authors: J. Guéna, D. Chauvat, Ph. Jacquier, E. Jahier, M. Lintz, A. V. Papoyan, S. Sanguinetti, D. Sarkisyan, A. Wasan, M. A. Bouchiat

    Abstract: We have detected, by using stimulated emission, an Atomic Parity Violation (APV) in the form of a chiral optical gain of a cesium vapor on the 7S - 6P$_{3/2}$ transition,consecutive to linearly polarized 6S-7S excitation. We demonstrate the validity of this detection method of APV, by presenting a 9% accurate measurement of expected sign and magnitude. We underline several advantages of this ent… ▽ More

    Submitted 17 October, 2002; originally announced October 2002.

    Comments: 4 pages, 2 figures