-
Near-to mid-IR spectral purity transfer with a tunable frequency comb: methanol frequency metrology over a record frequency span
Authors:
D B A Tran,
Olivier Lopez,
M Manceau,
A Goncharov,
Michel Abgrall,
H Alvarez-Martinez,
R Le Targat,
E Cantin,
P. -E Pottie,
A Amy-Klein,
B Darquié
Abstract:
We report the development and operation of a frequency-comb-assisted high-resolution mid-infrared molecular spectrometer combining high spectral purity, SI-traceability, wide tunability and high sensitivity. An optical frequency comb is used to transfer the spectral purity of a SI-traceable 1.54 $μ$m metrology-grade frequency reference to a 10.3 $μ$m quantum cascade laser (QCL). The near-infrared…
▽ More
We report the development and operation of a frequency-comb-assisted high-resolution mid-infrared molecular spectrometer combining high spectral purity, SI-traceability, wide tunability and high sensitivity. An optical frequency comb is used to transfer the spectral purity of a SI-traceable 1.54 $μ$m metrology-grade frequency reference to a 10.3 $μ$m quantum cascade laser (QCL). The near-infrared reference is operated at the French time/frequency metrology institute, calibrated there to primary frequency standards, and transferred to Laboratoire de Physique des Lasers via the REFIMEVE fiber network. The QCL exhibits a sub-10 --15 frequency stability from 0.1 to 10 s and its frequency is traceable to the SI with a total uncertainty better than 4 x 10 --14 after 1-s averaging time. We have developed the instrumentation allowing comb modes to be continuously tuned over 9 GHz resulting in a QCL of record spectral purity uninterruptedly tunable at the precision of the reference over an unprecedented span of 1.4 GHz. We have used our apparatus to conduct sub-Doppler spectroscopy of methanol in a multi-pass cell, demonstrating state-of-art frequency uncertainties down to the few kilohertz level. We have observed weak intensity resonances unreported so far, resolved subtle doublets never seen before and brought to light discrepancies with the HITRAN database. This demonstrates the potential of our apparatus for probing subtle internal molecular processes, building accurate spectroscopic models of polyatomic molecules of atmospheric or astrophysical interest, and carrying out precise spectroscopic tests of fundamental physics.
△ Less
Submitted 27 October, 2023;
originally announced October 2023.
-
Limitations due to residual interference in a fiber-based optical frequency reference at 1.55 $μ$m
Authors:
Karim Manamanni,
Tatiana Steshchenko,
Fabrice Wiotte,
Rodolphe Le Targat,
Michel Abgrall,
Olivier Lopez,
Étienne Cantin,
Paul-Éric Pottie,
Anne Amy-Klein,
Vincent Roncin,
Frédéric Du-Burck
Abstract:
We present an experimental investigation of the stability limits specific to optical frequency standards using a fiber-optic architecture and semiconductor lasers. A compact setup composed of a semiconductor laser frequency-locked onto an acetylene transition detected in saturated absorption has been implemented using only fiber-optic components. Fiber optic technology allows compact and reliable…
▽ More
We present an experimental investigation of the stability limits specific to optical frequency standards using a fiber-optic architecture and semiconductor lasers. A compact setup composed of a semiconductor laser frequency-locked onto an acetylene transition detected in saturated absorption has been implemented using only fiber-optic components. Fiber optic technology allows compact and reliable solutions for various applications. However, for high sensitivity and stability applications such as metrology, residual reflections induced by optical index inhomogeneities in connectors and fiber-coupled components leading to spurious interference significantly limit performance. We have examined the origin of the interference fringes superimposed on the detected signal and the limitations they cause to the frequency stability of the reference. The effects of temperature and beam power fluctuations are also examined. Our results show that the frequency stability is limited in the 10-13 range by the effect of interference fringes due to use of fiber components.
△ Less
Submitted 28 March, 2022; v1 submitted 19 January, 2022;
originally announced January 2022.
-
A new experiment to test parity symmetry in cold chiral molecules using vibrational spectroscopy
Authors:
A Cournol,
M. Manceau,
M. Pierens,
L Lecordier,
D Tran,
R. Santagata,
B. Argence,
A Goncharov,
O. Lopez,
M. Abgrall,
Y. Le Coq,
R. Le Targat,
H Alvarez Martinez,
W Lee,
D Xu,
P-E Pottie,
R Hendricks,
T Wall,
J Bieniewska,
B Sauer,
M. Tarbutt,
A. Amy-Klein,
S. Tokunaga,
B. Darquié
Abstract:
We present a brief review of our progress towards measuring parity violation in heavy-metal chiral complexes using mid-infrared Ramsey interferometry. We discuss our progress addressing the main challenges, including the development of buffer-gas sources of slow, cold polyatomic molecules, and the frequency-stabilisation of quantum cascade lasers calibrated using primary frequency standards. We re…
▽ More
We present a brief review of our progress towards measuring parity violation in heavy-metal chiral complexes using mid-infrared Ramsey interferometry. We discuss our progress addressing the main challenges, including the development of buffer-gas sources of slow, cold polyatomic molecules, and the frequency-stabilisation of quantum cascade lasers calibrated using primary frequency standards. We report investigations on achiral test species of which promising chiral derivatives have been synthesized.
△ Less
Submitted 12 December, 2019;
originally announced December 2019.
-
Direct comparisons of European primary and secondary frequency standards via satellite techniques
Authors:
F. Riedel,
A. Al-Masoudi,
E. Benkler,
S. Dörscher,
V. Gerginov,
C. Grebing,
S. Häfner,
N. Huntemann,
B. Lipphardt,
C. Lisdat,
E. Peik,
D. Piester,
C. Sanner,
C. Tamm,
S. Weyers,
H. Denker,
L. Timmen,
C. Voigt,
D. Calonico,
G. Cerretto,
G. A. Costanzo,
F. Levi,
I. Sesia,
J. Achkar,
J. Guèna
, et al. (24 additional authors not shown)
Abstract:
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taki…
▽ More
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taking into account correlations and gaps in the measurement data, combined overall uncertainties in the range of $1.8 \times 10^{-16}$ to $3.5 \times 10^{-16}$ for the optical clock comparisons were found. The comparison of the fountain clocks yields results with a maximum relative frequency difference of $6.9 \times 10^{-16}$, and combined overall uncertainties in the range of $4.8 \times 10^{-16}$ to $7.7 \times 10^{-16}$.
△ Less
Submitted 9 October, 2019;
originally announced October 2019.
-
High-precision methanol spectroscopy with a widely tunable SI-traceable frequency-comb-based mid-infrared QCL
Authors:
R. Santagata,
D. Tran,
B. Argence,
O. Lopez,
S. Tokunaga,
F. Wiotte,
H. Mouhamad,
A. Goncharov,
M. Abgrall,
Y. Le Coq,
H. Alvarez-Martinez,
R. Le Targat,
W. Lee,
D. Xu,
P. -E. Pottie,
B. Darquié,
A. Amy-Klein
Abstract:
There is an increasing demand for precise molecular spectroscopy, in particular in the mid-infrared fingerprint window that hosts a considerable number of vibrational signatures, whether it be for modeling our atmosphere, interpreting astrophysical spectra or testing fundamental physics. We present a high-resolution mid-infrared spectrometer traceable to primary frequency standards. It combines a…
▽ More
There is an increasing demand for precise molecular spectroscopy, in particular in the mid-infrared fingerprint window that hosts a considerable number of vibrational signatures, whether it be for modeling our atmosphere, interpreting astrophysical spectra or testing fundamental physics. We present a high-resolution mid-infrared spectrometer traceable to primary frequency standards. It combines a widely tunable ultra-narrow Quantum Cascade Laser (QCL), an optical frequency comb and a compact multipass cell. The QCL frequency is stabilized onto a comb controlled with a remote near-infrared ultra-stable laser, transferred through a fiber link. The resulting QCL frequency stability is below 10-15 from 0.1 to 10s and its frequency uncertainty of 4x10-14 is given by the remote frequency standards. Continuous tuning over ~400 MHz is reported. We use the apparatus to perform saturated absorption spectroscopy of methanol in the low-pressure multipass cell and demonstrate a statistical uncertainty at the kHz level on transition center frequencies, confirming its potential for driving the next generation technology required for precise spectroscopic measurements.
△ Less
Submitted 23 July, 2019;
originally announced July 2019.
-
New measurement of the $1S-3S$ transition frequency of hydrogen: contribution to the proton charge radius puzzle
Authors:
Hélène Fleurbaey,
Sandrine Galtier,
Simon Thomas,
Marie Bonnaud,
Lucile Julien,
François Biraben,
François Nez,
Michel Abgrall,
Jocelyne Guéna
Abstract:
We present a new measurement of the $1S-3S$ two-photon transition frequency of hydrogen, realized with a continuous-wave excitation laser at 205 nm on a room-temperature atomic beam, with a relative uncertainty of $9\times10^{-13}$. The proton charge radius deduced from this measurement, $r_\text{p}=0.877(13)$ fm, is in very good agreement with the current CODATA-recommended value. This result con…
▽ More
We present a new measurement of the $1S-3S$ two-photon transition frequency of hydrogen, realized with a continuous-wave excitation laser at 205 nm on a room-temperature atomic beam, with a relative uncertainty of $9\times10^{-13}$. The proton charge radius deduced from this measurement, $r_\text{p}=0.877(13)$ fm, is in very good agreement with the current CODATA-recommended value. This result contributes to the ongoing search to solve the proton charge radius puzzle, which arose from a discrepancy between the CODATA value and a more precise determination of $r_\text{p}$ from muonic hydrogen spectroscopy.
△ Less
Submitted 27 April, 2018; v1 submitted 26 January, 2018;
originally announced January 2018.
-
First international comparison of fountain primary frequency standards via a long distance optical fiber link
Authors:
J. Guéna,
S. Weyers,
M. Abgrall,
C. Grebing,
V. Gerginov,
P. Rosenbusch,
S. Bize,
B. Lipphardt,
H. Denker,
N. Quintin,
S. M. F. Raupach,
D. Nicolodi,
F. Stefani,
N. Chiodo,
S. Koke,
A. Kuhl,
F. Wiotte,
F. Meynadier,
E. Camisard,
C. Chardonnet,
Y. Le Coq,
M. Lours,
G. Santarelli,
A. Amy-Klein,
R. Le Targat
, et al. (3 additional authors not shown)
Abstract:
We report on the first comparison of distant caesium fountain primary frequency standards (PFSs) via an optical fiber link. The 1415 km long optical link connects two PFSs at LNE-SYRTE (Laboratoire National de métrologie et d'Essais - SYstème de Références Temps-Espace) in Paris (France) with two at PTB (Physikalisch-Technische Bundesanstalt) in Braunschweig (Germany). For a long time, these PFSs…
▽ More
We report on the first comparison of distant caesium fountain primary frequency standards (PFSs) via an optical fiber link. The 1415 km long optical link connects two PFSs at LNE-SYRTE (Laboratoire National de métrologie et d'Essais - SYstème de Références Temps-Espace) in Paris (France) with two at PTB (Physikalisch-Technische Bundesanstalt) in Braunschweig (Germany). For a long time, these PFSs have been major contributors to accuracy of the International Atomic Time (TAI), with stated accuracies of around $3\times 10^{-16}$. They have also been the references for a number of absolute measurements of clock transition frequencies in various optical frequency standards in view of a future redefinition of the second. The phase coherent optical frequency transfer via a stabilized telecom fiber link enables far better resolution than any other means of frequency transfer based on satellite links. The agreement for each pair of distant fountains compared is well within the combined uncertainty of a few 10$^{-16}$ for all the comparisons, which fully supports the stated PFSs' uncertainties. The comparison also includes a rubidium fountain frequency standard participating in the steering of TAI and enables a new absolute determination of the $^{87}$Rb ground state hyperfine transition frequency with an uncertainty of $3.1\times 10^{-16}$.
This paper is dedicated to the memory of André Clairon, who passed away on the 24$^{th}$ of December 2015, for his pioneering and long-lasting efforts in atomic fountains. He also pioneered optical links from as early as 1997.
△ Less
Submitted 14 March, 2017; v1 submitted 2 March, 2017;
originally announced March 2017.
-
Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
Authors:
Jérôme Lodewyck,
Sławomir Bilicki,
Eva Bookjans,
Jean-Luc Robyr,
Chunyan Shi,
Grégoire Vallet,
Rodolphe Le Targat,
Daniele Nicolodi,
Yann Le Coq,
Jocelyne Guéna,
Michel Abgrall,
Peter Rosenbusch,
Sébastien Bize
Abstract:
Optical lattice clocks are at the forefront of frequency metrology. Both the instability and systematic uncertainty of these clocks have been reported to be two orders of magnitude smaller than the best microwave clocks. For this reason, a redefinition of the SI second based on optical clocks seems possible in the near future. However, the operation of optical lattice clocks has not yet reached th…
▽ More
Optical lattice clocks are at the forefront of frequency metrology. Both the instability and systematic uncertainty of these clocks have been reported to be two orders of magnitude smaller than the best microwave clocks. For this reason, a redefinition of the SI second based on optical clocks seems possible in the near future. However, the operation of optical lattice clocks has not yet reached the reliability that microwave clocks have achieved so far. In this paper, we report on the operation of a strontium optical lattice clock that spans several weeks, with more than 80% uptime. We make use of this long integration time to demonstrate a reproducible measurement of frequency ratios between the strontium clock transition and microwave Cs primary and Rb secondary frequency standards.
△ Less
Submitted 12 May, 2016;
originally announced May 2016.
-
Searching for an oscillating massive scalar field as a dark matter candidate using atomic hyperfine frequency comparisons
Authors:
A. Hees,
J. Guéna,
M. Abgrall,
S. Bize,
P. Wolf
Abstract:
We use six years of accurate hyperfine frequency comparison data of the dual rubidium and caesium cold atom fountain FO2 at LNE-SYRTE to search for a massive scalar dark matter candidate. Such a scalar field can induce harmonic variations of the fine structure constant, of the mass of fermions and of the quantum chromodynamic mass scale, which will directly impact the rubidium/caesium hyperfine tr…
▽ More
We use six years of accurate hyperfine frequency comparison data of the dual rubidium and caesium cold atom fountain FO2 at LNE-SYRTE to search for a massive scalar dark matter candidate. Such a scalar field can induce harmonic variations of the fine structure constant, of the mass of fermions and of the quantum chromodynamic mass scale, which will directly impact the rubidium/caesium hyperfine transition frequency ratio. We find no signal consistent with a scalar dark matter candidate but provide improved constraints on the coupling of the putative scalar field to standard matter. Our limits are complementary to previous results that were only sensitive to the fine structure constant, and improve them by more than an order of magnitude when only a coupling to electromagnetism is assumed.
△ Less
Submitted 28 July, 2016; v1 submitted 28 April, 2016;
originally announced April 2016.
-
Comparing a mercury optical lattice clock with microwave and optical frequency standards
Authors:
R Tyumenev,
M Favier,
S Bilicki,
E Bookjans,
R Le Targat,
J Lodewyck,
D Nicolodi,
Y Le Coq,
M Abgrall,
J Guéna,
L De Sarlo,
S Bize
Abstract:
In this paper we report the evaluation of an optical lattice clock based on neutral mercury down to a relative uncertainty of $1.7\times 10^{-16}$. Comparing this characterized frequency standard to a Cs atomic fountain we determine the absolute frequency of the $^1S_0 \rightarrow \phantom{}^3P_0$ transition of $^{199}$Hg as $ν_{\mathrm{Hg}} = 1 128\,575\,290\,808\,154.62\,$Hz $\pm\,0.19\,$Hz (sta…
▽ More
In this paper we report the evaluation of an optical lattice clock based on neutral mercury down to a relative uncertainty of $1.7\times 10^{-16}$. Comparing this characterized frequency standard to a Cs atomic fountain we determine the absolute frequency of the $^1S_0 \rightarrow \phantom{}^3P_0$ transition of $^{199}$Hg as $ν_{\mathrm{Hg}} = 1 128\,575\,290\,808\,154.62\,$Hz $\pm\,0.19\,$Hz (statistical) $\pm\,0.38\,$Hz (systematic), limited solely by the realization of the SI second. Furthermore, by comparing the mercury optical lattice clock to a Rb atomic fountain, we determine for the first time to our knowledge the ratio between the $^{199}$Hg clock transition and the $^{87}$Rb ground state hyperfine transition. Finally we present a direct optical to optical measurement of the $^{199}$Hg/$^{87}$Sr frequency ratio. The obtained value of $ν_{\mathrm{Hg}}/ν_{\mathrm{Sr}}=2.629\,314\,209\,898\,909\,15$ with a fractional uncertainty of $1.8\times10^{-16}$ is in excellent agreement with the same measurement obtained by Yamanaka et al. (arXiv:1503.07941). This makes this frequency ratio one of the few physical quantities agreed upon by different laboratories to this level of uncertainty. Frequency ratio measurements of the kind of those reported in this paper have a strong impact for frequency metrology but also for fundamental physics as they can be used to monitor putative variations of fundamental constants.
△ Less
Submitted 13 November, 2016; v1 submitted 7 March, 2016;
originally announced March 2016.
-
A clock network for geodesy and fundamental science
Authors:
C. Lisdat,
G. Grosche,
N. Quintin,
C. Shi,
S. M. F. Raupach,
C. Grebing,
D. Nicolodi,
F. Stefani,
A. Al-Masoudi,
S. Dörscher,
S. Häfner,
J. -L. Robyr,
N. Chiodo,
S. Bilicki,
E. Bookjans,
A. Koczwara,
S. Koke,
A. Kuhl,
F. Wiotte,
F. Meynadier,
E. Camisard,
M. Abgrall,
M. Lours,
T. Legero,
H. Schnatz
, et al. (10 additional authors not shown)
Abstract:
Leveraging the unrivaled performance of optical clocks in applications in fundamental physics beyond the standard model, in geo-sciences, and in astronomy requires comparing the frequency of distant optical clocks truthfully. Meeting this requirement, we report on the first comparison and agreement of fully independent optical clocks separated by 700 km being only limited by the uncertainties of t…
▽ More
Leveraging the unrivaled performance of optical clocks in applications in fundamental physics beyond the standard model, in geo-sciences, and in astronomy requires comparing the frequency of distant optical clocks truthfully. Meeting this requirement, we report on the first comparison and agreement of fully independent optical clocks separated by 700 km being only limited by the uncertainties of the clocks themselves. This is achieved by a phase-coherent optical frequency transfer via a 1415 km long telecom fiber link that enables substantially better precision than classical means of frequency transfer. The fractional precision in comparing the optical clocks of three parts in $10^{17}$ was reached after only 1000 s averaging time, which is already 10 times better and more than four orders of magnitude faster than with any other existing frequency transfer method. The capability of performing high resolution international clock comparisons paves the way for a redefinition of the unit of time and an all-optical dissemination of the SI-second.
△ Less
Submitted 24 November, 2015;
originally announced November 2015.
-
Atomic fountains and optical clocks at SYRTE: status and perspectives
Authors:
M. Abgrall,
B. Chupin,
L. De Sarlo,
J. Guéna,
Ph. Laurent,
Y. Le Coq,
R. Le Targat,
J. Lodewyck,
M. Lours,
P. Rosenbusch,
D. Rovera,
S. Bize
Abstract:
In this article, we report on the work done with the LNE-SYRTE atomic clock ensemble during the last 10 years. We cover progress made in atomic fountains and in their application to timekeeping. We also cover the development of optical lattice clocks based on strontium and on mercury. We report on tests of fundamental physical laws made with these highly accurate atomic clocks. We also report on w…
▽ More
In this article, we report on the work done with the LNE-SYRTE atomic clock ensemble during the last 10 years. We cover progress made in atomic fountains and in their application to timekeeping. We also cover the development of optical lattice clocks based on strontium and on mercury. We report on tests of fundamental physical laws made with these highly accurate atomic clocks. We also report on work relevant to a future possible redefinition of the SI second.
△ Less
Submitted 16 July, 2015;
originally announced July 2015.
-
Quantum cascade laser frequency stabilisation at the sub-Hz level
Authors:
Bérengère Argence,
Bruno Chanteau,
Olivier Lopez,
Daniele Nicolodi,
Michel Abgrall,
Christian Chardonnet,
Christophe Daussy,
Benoît Darquié,
Yann Le Coq,
Anne Amy-Klein
Abstract:
Quantum Cascade Lasers (QCL) are increasingly being used to probe the mid-infrared "molecular fingerprint" region. This prompted efforts towards improving their spectral performance, in order to reach ever-higher resolution and precision. Here, we report the stabilisation of a QCL onto an optical frequency comb. We demonstrate a relative stability and accuracy of 2x10-15 and 10-14, respectively. T…
▽ More
Quantum Cascade Lasers (QCL) are increasingly being used to probe the mid-infrared "molecular fingerprint" region. This prompted efforts towards improving their spectral performance, in order to reach ever-higher resolution and precision. Here, we report the stabilisation of a QCL onto an optical frequency comb. We demonstrate a relative stability and accuracy of 2x10-15 and 10-14, respectively. The comb is stabilised to a remote near-infrared ultra-stable laser referenced to frequency primary standards, whose signal is transferred via an optical fibre link. The stability and frequency traceability of our QCL exceed those demonstrated so far by two orders of magnitude. As a demonstration of its capability, we then use it to perform high-resolution molecular spectroscopy. We measure absorption frequencies with an 8x10-13 relative uncertainty. This confirms the potential of this setup for ultra-high precision measurements with molecules, such as our ongoing effort towards testing the parity symmetry by probing chiral species.
△ Less
Submitted 6 December, 2014;
originally announced December 2014.
-
Contributing to TAI with a Secondary Representation of the SI Second
Authors:
Jocelyne Guéna,
Michel Abgrall,
André Clairon,
Sébastien Bize
Abstract:
We report the first contribution to the international atomic time (TAI) based on a secondary representation of the SI second. This work is done with the LNE-SYRTE FO2-Rb fountain frequency standard using the $^{87}$Rb ground state hyperfine transition. We describe FO2-Rb and how it is connected to local and international time scales. We report on local measurements of this frequency standard in th…
▽ More
We report the first contribution to the international atomic time (TAI) based on a secondary representation of the SI second. This work is done with the LNE-SYRTE FO2-Rb fountain frequency standard using the $^{87}$Rb ground state hyperfine transition. We describe FO2-Rb and how it is connected to local and international time scales. We report on local measurements of this frequency standard in the SI system, i.e. against primary frequency standards, down to a fractional uncertainty of $4.4\times 10^{-16}$, and on the establishment of the recommended value for the $^{87}$Rb hyperfine transition by the CIPM. We also report on the process that led to the participation of the FO2-Rb frequency standard to $Circular~T$ and to the elaboration of TAI. This participation enables us to demonstrate absolute frequency measurement directly in terms of the SI second realized by the TAI ensemble with a statistical uncertainty of $1.1\times 10^{-16}$, therefore at the limit allowed by the accuracy of primary frequency standards. This work constitutes a demonstration of how other secondary representations, based on optical transitions, could also be used for TAI, and an investigation of a number of issues relevant to a future redefinition of the SI second.
△ Less
Submitted 29 January, 2014;
originally announced January 2014.
-
Mid-infrared laser phase-locking to a remote near-infrared frequency reference for high precision molecular spectroscopy
Authors:
Bruno Chanteau,
Olivier Lopez,
Wei Zhang,
Daniele Nicolodi,
Bérengère Argence,
Frédéric Auguste,
Michel Abgrall,
Christian Chardonnet,
Giorgio Santarelli,
Benoît Darquié,
Yann Le Coq,
Anne Amy-Klein
Abstract:
We present a new method for accurate mid-infrared frequency measurements and stabilization to a near-infrared ultra-stable frequency reference, transmitted with a long-distance fibre link and continuously monitored against state-of-the-art atomic fountain clocks. As a first application, we measure the frequency of an OsO4 rovibrational molecular line around 10 $μ$m with a state-of-the-art uncertai…
▽ More
We present a new method for accurate mid-infrared frequency measurements and stabilization to a near-infrared ultra-stable frequency reference, transmitted with a long-distance fibre link and continuously monitored against state-of-the-art atomic fountain clocks. As a first application, we measure the frequency of an OsO4 rovibrational molecular line around 10 $μ$m with a state-of-the-art uncertainty of 8x10-13. We also demonstrate the frequency stabilization of a mid-infrared laser with fractional stability better than 4x10-14 at 1 s averaging time and a line-width below 17 Hz. This new stabilization scheme gives us the ability to transfer frequency stability in the range of 10-15 or even better, currently accessible in the near-infrared or in the visible, to mid-infrared lasers in a wide frequency range.
△ Less
Submitted 29 April, 2013;
originally announced April 2013.
-
Experimenting an optical second with strontium lattice clocks
Authors:
R. Le Targat,
L. Lorini,
Y. Le Coq,
M. Zawada,
J. Guéna,
M. Abgrall,
M. Gurov,
P. Rosenbusch,
D. G. Rovera,
B. Nagórny,
R. Gartman,
P. G. Westergaard,
M. E. Tobar,
M. Lours,
G. Santarelli,
A. Clairon,
S. Bize,
P. Laurent,
P. Lemonde,
J. Lodewyck
Abstract:
Progress in realizing the SI second had multiple technological impacts and enabled to further constraint theoretical models in fundamental physics. Caesium microwave fountains, realizing best the second according to its current definition with a relative uncertainty of 2-4x10^(-16), have already been superseded by atomic clocks referenced to an optical transition, both more stable and more accurat…
▽ More
Progress in realizing the SI second had multiple technological impacts and enabled to further constraint theoretical models in fundamental physics. Caesium microwave fountains, realizing best the second according to its current definition with a relative uncertainty of 2-4x10^(-16), have already been superseded by atomic clocks referenced to an optical transition, both more stable and more accurate. Are we ready for a new definition of the second? Here we present an important step in this direction: our system of five clocks connects with an unprecedented consistency the optical and the microwave worlds. For the first time, two state-of-the-art strontium optical lattice clocks are proven to agree within their accuracy budget, with a total uncertainty of 1.6x10^(-16). Their comparison with three independent caesium fountains shows a degree of reproducibility henceforth solely limited at the level of 3.1x10^(-16) by the best realizations of the microwave-defined second.
△ Less
Submitted 31 July, 2013; v1 submitted 25 January, 2013;
originally announced January 2013.
-
Demonstration of a Dual Alkali Rb/Cs Atomic Fountain Clock
Authors:
J. Guéna,
P. Rosenbusch,
Ph. Laurent,
M. Abgrall,
D. Rovera,
M. Lours,
G. Santarelli,
M. E. Tobar,
S. Bize,
A. Clairon
Abstract:
We report the operation of a dual Rb/Cs atomic fountain clock. 133Cs and 87Rb atoms are cooled, launched, and detected simultaneously in LNE-SYRTE's FO2 double fountain. The dual clock operation occurs with no degradation of either the stability or the accuracy. We describe the key features for achieving such a simultaneous operation. We also report on the results of the first Rb/Cs frequency meas…
▽ More
We report the operation of a dual Rb/Cs atomic fountain clock. 133Cs and 87Rb atoms are cooled, launched, and detected simultaneously in LNE-SYRTE's FO2 double fountain. The dual clock operation occurs with no degradation of either the stability or the accuracy. We describe the key features for achieving such a simultaneous operation. We also report on the results of the first Rb/Cs frequency measurement campaign performed with FO2 in this dual atom clock configuration, including a new determination of the absolute 87Rb hyperfine frequency.
△ Less
Submitted 3 January, 2013;
originally announced January 2013.
-
Improved tests of Local Position Invariance using 87Rb and 133Cs fountains
Authors:
Jocelyne Guéna,
Michel Abgrall,
Daniele Rovera,
Peter Rosenbusch,
Michael E. Tobar,
Philippe Laurent,
André Clairon,
Sébastien Bize
Abstract:
We report tests of local position invariance based on measurements of the ratio of the ground state hyperfine frequencies of 133Cs and 87Rb in laser-cooled atomic fountain clocks. Measurements extending over 14 years set a stringent limit to a possible variation with time of this ratio: d ln(nu_Rb/nu_Cs)/dt=(-1.39 +/- 0.91)x 10-16 yr-1. This improves by a factor of 7.7 over our previous report (H.…
▽ More
We report tests of local position invariance based on measurements of the ratio of the ground state hyperfine frequencies of 133Cs and 87Rb in laser-cooled atomic fountain clocks. Measurements extending over 14 years set a stringent limit to a possible variation with time of this ratio: d ln(nu_Rb/nu_Cs)/dt=(-1.39 +/- 0.91)x 10-16 yr-1. This improves by a factor of 7.7 over our previous report (H. Marion et al., Phys. Rev. Lett. 90, 150801 (2003)). Our measurements also set the first limit to a fractional variation of the Rb/Cs ratio with gravitational potential at the level of c^2 d ln(nu_Rb/nu_Cs)/dU=(0.11 +/- 1.04)x 10^-6, providing a new stringent differential redshift test. The above limits equivalently apply to the fractional variation of the quantity alpha^{-0.49}x(g_Rb/g_Cs), which involves the fine structure constant alpha and the ratio of the nuclear g-factors of the two alkalis. The link with variations of the light quark mass is also presented together with a global analysis combining with other available highly accurate clock comparisons.
△ Less
Submitted 22 August, 2012; v1 submitted 18 May, 2012;
originally announced May 2012.
-
Progress in Atomic Fountains at LNE-SYRTE
Authors:
Jocelyne Guéna,
Michel Abgrall,
Daniele Rovera,
Philippe Laurent,
Baptiste Chupin,
Michel Lours,
Giorgio Santarelli,
Peter Rosenbusch,
Michael E. Tobar,
Ruoxin Li,
Kurt Gibble,
André Clairon,
Sébastien Bize
Abstract:
We give an overview of the work done with the Laboratoire National de Métrologie et d'Essais-Systèmes de Référence Temps-Espace (LNE-SYRTE) fountain ensemble during the last five years. After a description of the clock ensemble, comprising three fountains, FO1, FO2, and FOM, and the newest developments, we review recent studies of several systematic frequency shifts. This includes the distributed…
▽ More
We give an overview of the work done with the Laboratoire National de Métrologie et d'Essais-Systèmes de Référence Temps-Espace (LNE-SYRTE) fountain ensemble during the last five years. After a description of the clock ensemble, comprising three fountains, FO1, FO2, and FOM, and the newest developments, we review recent studies of several systematic frequency shifts. This includes the distributed cavity phase shift, which we evaluate for the FO1 and FOM fountains, applying the techniques of our recent work on FO2. We also report calculations of the microwave lensing frequency shift for the three fountains, review the status of the blackbody radiation shift, and summarize recent experimental work to control microwave leakage and spurious phase perturbations. We give current accuracy budgets. We also describe several applications in time and frequency metrology: fountain comparisons, calibrations of the international atomic time, secondary representation of the SI second based on the 87Rb hyperfine frequency, absolute measurements of optical frequencies, tests of the T2L2 satellite laser link, and review fundamental physics applications of the LNE-SYRTE fountain ensemble. Finally, we give a summary of the tests of the PHARAO cold atom space clock performed using the FOM transportable fountain.
△ Less
Submitted 16 April, 2012;
originally announced April 2012.
-
Improved Measurement of the Hydrogen 1S - 2S Transition Frequency
Authors:
Christian G. Parthey,
Arthur Matveev,
Janis Alnis,
Birgitta Bernhardt,
Axel Beyer,
Ronald Holzwarth,
Aliaksei Maistrou,
Randolf Pohl,
Katharina Predehl,
Thomas Udem,
Tobias Wilken,
Nikolai Kolachevsky,
Michel Abgrall,
Daniele Rovera,
Christophe Salomon,
Philippe Laurent,
Theodor W. Hänsch
Abstract:
We have measured the 1S - 2S transition frequency in atomic hydrogen via two photon spectroscopy on a 5.8 K atomic beam. We obtain $f_{1S-2S} = 2 466 061 413 187 035 (10)$ Hz for the hyperfine centroid. This is a fractional frequency uncertainty of $4.2\times 10^{-15}$ improving the previous measure- ment by our own group [M. Fischer et al., Phys. Rev. Lett. 92, 230802 (2004)] by a factor of 3.3.…
▽ More
We have measured the 1S - 2S transition frequency in atomic hydrogen via two photon spectroscopy on a 5.8 K atomic beam. We obtain $f_{1S-2S} = 2 466 061 413 187 035 (10)$ Hz for the hyperfine centroid. This is a fractional frequency uncertainty of $4.2\times 10^{-15}$ improving the previous measure- ment by our own group [M. Fischer et al., Phys. Rev. Lett. 92, 230802 (2004)] by a factor of 3.3. The probe laser frequency was phase coherently linked to the mobile cesium fountain clock FOM via a frequency comb.
△ Less
Submitted 15 July, 2011;
originally announced July 2011.
-
Ultra-low noise microwave generation with fiber-based optical frequency comb and application to atomic fountain clock
Authors:
J. Millo,
M. Abgrall,
M. Lours,
E. M. L. English,
H. Jiang,
J. Guena,
A. Clairon,
S. Bize,
Y. Le Coq,
G. Santarelli,
M. E. Tobar
Abstract:
We demonstrate the use of a fiber-based femtosecond laser locked onto an ultra-stable optical cavity to generate a low-noise microwave reference signal. Comparison with both a liquid Helium cryogenic sapphire oscillator (CSO) and a Ti:Sapphire-based optical frequency comb system exhibit a stability about $3\times10^{-15}$ between 1 s and 10 s. The microwave signal from the fiber system is used t…
▽ More
We demonstrate the use of a fiber-based femtosecond laser locked onto an ultra-stable optical cavity to generate a low-noise microwave reference signal. Comparison with both a liquid Helium cryogenic sapphire oscillator (CSO) and a Ti:Sapphire-based optical frequency comb system exhibit a stability about $3\times10^{-15}$ between 1 s and 10 s. The microwave signal from the fiber system is used to perform Ramsey spectroscopy in a state-of-the-art Cesium fountain clock. The resulting clock system is compared to the CSO and exhibits a stability of $3.5\times10^{-14}τ^{-1/2}$. Our continuously operated fiber-based system therefore demonstrates its potential to replace the CSO for atomic clocks with high stability in both the optical and microwave domain, most particularly for operational primary frequency standards.
△ Less
Submitted 23 January, 2009;
originally announced January 2009.
-
Absolute frequency measurement of the 40Ca+ S1/2 - D5/2 clock transition
Authors:
M. Chwalla,
J. Benhelm,
K. Kim,
G. Kirchmair,
T. Monz,
M. Riebe,
P. Schindler,
A. S. Villar,
W. Haensel,
C. F. Roos,
R. Blatt,
M. Abgrall,
G. Santarelli,
G. D. Rovera,
Ph. Laurent
Abstract:
We report on the first absolute transition frequency measurement at the 10^{-15} level with a single, laser-cooled 40Ca+ ion in a linear Paul trap. For this measurement, a frequency comb is referenced to the transportable Cs atomic fountain clock of LNE-SYRTE and is used to measure the S1/2-D5/2 electric-quadrupole transition frequency. After the correction of systematic shifts, the clock transi…
▽ More
We report on the first absolute transition frequency measurement at the 10^{-15} level with a single, laser-cooled 40Ca+ ion in a linear Paul trap. For this measurement, a frequency comb is referenced to the transportable Cs atomic fountain clock of LNE-SYRTE and is used to measure the S1/2-D5/2 electric-quadrupole transition frequency. After the correction of systematic shifts, the clock transition frequency f_Ca+ = 411 042 129 776 393.2 (1.0) Hz is obtained, which corresponds to a fractional uncertainty within a factor of three of the Cs standard. Future improvements are expected to lead to an uncertainty surpassing the best Cs fountain clocks. In addition, we determine the Lande g-factor of the D5/2 level to be gD5/2=1.2003340(3).
△ Less
Submitted 9 June, 2008;
originally announced June 2008.
-
An Optical Lattice Clock with Spin-polarized 87Sr Atoms
Authors:
Xavier Baillard,
Mathilde Fouché,
Rodolphe Le Targat,
Philip G. Westergaard,
Arnaud Lecallier,
Frédéric Chapelet,
Michel Abgrall,
Giovanni D. Rovera,
Philippe Laurent,
Peter Rosenbusch,
Sébastien Bize,
Giorgio Santarelli,
André Clairon,
Pierre Lemonde,
Gesine Grosche,
Burghard Lipphardt,
Harald Schnatz
Abstract:
We present a new evaluation of an 87Sr optical lattice clock using spin polarized atoms. The frequency of the 1S0-3P0 clock transition is found to be 429 228 004 229 873.6 Hz with a fractional accuracy of 2.6 10^{-15}, a value that is comparable to the frequency difference between the various primary standards throughout the world. This measurement is in excellent agreement with a previous one o…
▽ More
We present a new evaluation of an 87Sr optical lattice clock using spin polarized atoms. The frequency of the 1S0-3P0 clock transition is found to be 429 228 004 229 873.6 Hz with a fractional accuracy of 2.6 10^{-15}, a value that is comparable to the frequency difference between the various primary standards throughout the world. This measurement is in excellent agreement with a previous one of similar accuracy.
△ Less
Submitted 29 September, 2007;
originally announced October 2007.
-
Cold atom Clocks and Applications
Authors:
S. Bize,
P. Laurent,
M. Abgrall,
H. Marion,
I. Maksimovic,
L. Cacciapuoti,
J. Gruenert,
C. Vian,
F. Pereira dos Santos,
P. Rosenbusch,
P. Lemonde,
G. Santarelli,
P. Wolf,
A. Clairon,
A. Luiten,
M. Tobar,
C. Salomon
Abstract:
This paper describes advances in microwave frequency standards using laser-cooled atoms at BNM-SYRTE. First, recent improvements of the $^{133}$Cs and $^{87}$Rb atomic fountains are described. Thanks to the routine use of a cryogenic sapphire oscillator as an ultra-stable local frequency reference, a fountain frequency instability of $1.6\times 10^{-14}τ^{-1/2}$ where $τ$ is the measurement time…
▽ More
This paper describes advances in microwave frequency standards using laser-cooled atoms at BNM-SYRTE. First, recent improvements of the $^{133}$Cs and $^{87}$Rb atomic fountains are described. Thanks to the routine use of a cryogenic sapphire oscillator as an ultra-stable local frequency reference, a fountain frequency instability of $1.6\times 10^{-14}τ^{-1/2}$ where $τ$ is the measurement time in seconds is measured. The second advance is a powerful method to control the frequency shift due to cold collisions. These two advances lead to a frequency stability of $2\times 10^{-16}$ at $50,000s for the first time for primary standards. In addition, these clocks realize the SI second with an accuracy of $7\times 10^{-16}$, one order of magnitude below that of uncooled devices. In a second part, we describe tests of possible variations of fundamental constants using $^{87}$Rb and $^{133}$Cs fountains. Finally we give an update on the cold atom space clock PHARAO developed in collaboration with CNES. This clock is one of the main instruments of the ACES/ESA mission which is scheduled to fly on board the International Space Station in 2008, enabling a new generation of relativity tests.
△ Less
Submitted 22 February, 2005;
originally announced February 2005.
-
New Limits to the Drift of Fundamental Constants from Laboratory Measurements
Authors:
M. Fischer,
N. Kolachevsky,
M. Zimmermann,
R. Holzwarth,
Th. Udem,
T. W. Haensch,
M. Abgrall,
J. Gruenert,
I. Maksimovic,
S. Bize,
H. Marion,
F. Pereira Dos Santos,
P. Lemonde,
G. Santarelli,
P. Laurent,
A. Clairon,
C. Salomon,
M. Haas,
U. D. Jentschura,
C. H. Keitel
Abstract:
We have remeasured the absolute $1S$-$2S$ transition frequency $ν_{\rm {H}}$ in atomic hydrogen. A comparison with the result of the previous measurement performed in 1999 sets a limit of $(-29\pm 57)$ Hz for the drift of $ν_{\rm {H}}$ with respect to the ground state hyperfine splitting $ν_{\rm {Cs}}$ in $^{133}$Cs. Combining this result with the recently published optical transition frequency…
▽ More
We have remeasured the absolute $1S$-$2S$ transition frequency $ν_{\rm {H}}$ in atomic hydrogen. A comparison with the result of the previous measurement performed in 1999 sets a limit of $(-29\pm 57)$ Hz for the drift of $ν_{\rm {H}}$ with respect to the ground state hyperfine splitting $ν_{\rm {Cs}}$ in $^{133}$Cs. Combining this result with the recently published optical transition frequency in $^{199}$Hg$^+$ against $ν_{\rm {Cs}}$ and a microwave $^{87}$Rb and $^{133}$Cs clock comparison, we deduce separate limits on $\dotα/α= (-0.9\pm 2.9)\times 10^{-15}$ yr$^{-1}$ and the fractional time variation of the ratio of Rb and Cs nuclear magnetic moments $μ_{\rm {Rb}}/μ_{\rm {Cs}}$ equal to $(-0.5 \pm 1.7)\times 10^{-15}$ yr$^{-1}$. The latter provides information on the temporal behavior of the constant of strong interaction.
△ Less
Submitted 4 June, 2004; v1 submitted 12 December, 2003;
originally announced December 2003.
-
Precision Spectroscopy of Atomic Hydrogen and Variations of Fundamental Constants
Authors:
M. Fischer,
N. Kolachevsky,
M. Zimmermann,
R. Holzwarth,
Th. Udem,
T. W. Hänsch,
M. Abgrall,
J. Grünert,
I. Maksimovic,
S. Bize,
H. Marion,
F. Pereira Dos Santos,
P. Lemonde,
G. Santarelli,
P. Laurent,
A. Clairon,
C. Salomon
Abstract:
In 2003 we have measured the absolute frequency of the $(1S, F=1, m_F=\pm 1) \leftrightarrow (2S, F'=1, m_F'=\pm 1)$ two-photon transition in atomic hydrogen. We observed a variation of $(-29\pm 57)$ Hz over a 44 months interval separating this measurement from the previous one performed in 1999. We have combined this result with recently published results of optical transition frequency measure…
▽ More
In 2003 we have measured the absolute frequency of the $(1S, F=1, m_F=\pm 1) \leftrightarrow (2S, F'=1, m_F'=\pm 1)$ two-photon transition in atomic hydrogen. We observed a variation of $(-29\pm 57)$ Hz over a 44 months interval separating this measurement from the previous one performed in 1999. We have combined this result with recently published results of optical transition frequency measurement in the $^{199}$Hg$^+$ ion and and comparison between clocks based on $^{87}$Rb and $^{133}$Cs. From this combination we deduce the stringent limits for fractional time variation of the fine structure constant $\partial/{\partial t}(\ln α)=(-0.9\pm 4.2)\times 10^{-15}$ yr$^{-1}$ and for the ratio of $^{87}$Rb and $^{133}$Cs spin magnetic moments $\partial/{\partial t}(\ln[μ_{\rm {Rb}}/μ_{\rm {Cs}}])=(0.5\pm 2.1)\times 10^{-15}$ yr$^{-1}$. This is the first precise restriction for the fractional time variation of $α$ made without assumptions about the relative drifts of the constants of electromagnetic, strong and weak interactions.
△ Less
Submitted 27 July, 2004; v1 submitted 26 November, 2003;
originally announced November 2003.
-
A Search for Variations of Fundamental Constants using Atomic Fountain Clocks
Authors:
H. Marion,
F. Pereira Dos Santos,
M. Abgrall,
S. Zhang,
Y. Sortais,
S. Bize,
I. Maksimovic,
D. Calonico,
J. Gruenert,
C. Mandache,
P. Lemonde,
G. Santarelli,
Ph. Laurent,
A. Clairon,
C. Salomon
Abstract:
Over five years we have compared the hyperfine frequencies of 133Cs and 87Rb atoms in their electronic ground state using several laser cooled 133Cs and 87Rb atomic fountains with an accuracy of ~10^{-15}. These measurements set a stringent upper bound to a possible fractional time variation of the ratio between the two frequencies : (d/dt)ln(nu_Rb/nu_Cs)=(0.2 +/- 7.0)*10^{-16} yr^{-1} (1 sigma…
▽ More
Over five years we have compared the hyperfine frequencies of 133Cs and 87Rb atoms in their electronic ground state using several laser cooled 133Cs and 87Rb atomic fountains with an accuracy of ~10^{-15}. These measurements set a stringent upper bound to a possible fractional time variation of the ratio between the two frequencies : (d/dt)ln(nu_Rb/nu_Cs)=(0.2 +/- 7.0)*10^{-16} yr^{-1} (1 sigma uncertainty). The same limit applies to a possible variation of the quantity (mu_Rb/mu_Cs)*alpha^{-0.44}, which involves the ratio of nuclear magnetic moments and the fine structure constant.
△ Less
Submitted 31 December, 2002;
originally announced December 2002.