Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content

Showing 1–3 of 3 results for author: Wilken, T

Searching in archive physics. Search in all archives.
.
  1. Improved Measurement of the Hydrogen 1S - 2S Transition Frequency

    Authors: Christian G. Parthey, Arthur Matveev, Janis Alnis, Birgitta Bernhardt, Axel Beyer, Ronald Holzwarth, Aliaksei Maistrou, Randolf Pohl, Katharina Predehl, Thomas Udem, Tobias Wilken, Nikolai Kolachevsky, Michel Abgrall, Daniele Rovera, Christophe Salomon, Philippe Laurent, Theodor W. Hänsch

    Abstract: We have measured the 1S - 2S transition frequency in atomic hydrogen via two photon spectroscopy on a 5.8 K atomic beam. We obtain $f_{1S-2S} = 2 466 061 413 187 035 (10)$ Hz for the hyperfine centroid. This is a fractional frequency uncertainty of $4.2\times 10^{-15}$ improving the previous measure- ment by our own group [M. Fischer et al., Phys. Rev. Lett. 92, 230802 (2004)] by a factor of 3.3.… ▽ More

    Submitted 15 July, 2011; originally announced July 2011.

    Comments: 5 pages, 4 figures

  2. Precision spectroscopy of the 3s-3p fine structure doublet in Mg+

    Authors: V. Batteiger, S. Knünz, M. Herrmann, G. Saathoff, H. A. Schüssler, B. Bernhardt, T. Wilken, R. Holzwarth, T. W. Hänsch, Th. Udem

    Abstract: We apply a recently demonstrated method for precision spectroscopy on strong transitions in trapped ions to measure both fine structure components of the 3s-3p transition in 24-Mg+ and 26-Mg+. We deduce absolute frequency reference data for transition frequencies, isotope shifts and fine structure splittings that are in particular useful for comparison with quasar absorption spectra, which test… ▽ More

    Submitted 2 July, 2009; originally announced July 2009.

  3. Sub-Hz line width diode lasers by stabilization to vibrationally and thermally compensated ULE Fabry-Perot cavities

    Authors: J. Alnis, A. Matveev, N. Kolachevsky, T. Wilken, Th. Udem, T. W. Haensch

    Abstract: We achieved a 0.5 Hz optical beat note line width with ~ 0.1 Hz/s frequency drift at 972 nm between two external cavity diode lasers independently stabilized to two vertically mounted Fabry-Perot (FP) reference cavities. Vertical FP reference cavities are suspended in mid-plane such that the influence of vertical vibrations to the mirror separation is significantly suppressed. This makes the set… ▽ More

    Submitted 28 January, 2008; originally announced January 2008.

    Comments: submitted to Applied Physics B

    Journal ref: Phys. Rev. A 77, 053809 (2008)