Calibration and Physics with ARA Station 1: A Unique Askaryan Radio Array Detector
Authors:
M. F. H Seikh,
D. Z. Besson,
S. Ali,
P. Allison,
S. Archambault,
J. J. Beatty,
A. Bishop,
P. Chen,
Y. C. Chen,
B. A. Clark,
W. Clay,
A. Connolly,
K. Couberly,
L. Cremonesi,
A. Cummings,
P. Dasgupta,
R. Debolt,
S. De Kockere,
K. D. de Vries,
C. Deaconu,
M. A. DuVernois,
J. Flaherty,
E. Friedman,
R. Gaior,
P. Giri
, et al. (48 additional authors not shown)
Abstract:
The Askaryan Radio Array Station 1 (A1), the first among five autonomous stations deployed for the ARA experiment at the South Pole, is a unique ultra-high energy neutrino (UHEN) detector based on the Askaryan effect that uses Antarctic ice as the detector medium. Its 16 radio antennas (distributed across 4 strings, each with 2 Vertically Polarized (VPol), 2 Horizontally Polarized (HPol) receivers…
▽ More
The Askaryan Radio Array Station 1 (A1), the first among five autonomous stations deployed for the ARA experiment at the South Pole, is a unique ultra-high energy neutrino (UHEN) detector based on the Askaryan effect that uses Antarctic ice as the detector medium. Its 16 radio antennas (distributed across 4 strings, each with 2 Vertically Polarized (VPol), 2 Horizontally Polarized (HPol) receivers), and 2 strings of transmitting antennas (calibration pulsers, CPs), each with 1 VPol and 1 HPol channel, are deployed at depths less than 100 m within the shallow firn zone of the 2.8 km thick South Pole (SP) ice. We apply different methods to calibrate its Ice Ray Sampler second generation (IRS2) chip for timing offset and ADC-to-Voltage conversion factors using a known continuous wave input signal to the digitizer, and achieve a precision of sub-nanoseconds. We achieve better calibration for odd, compared to even samples, and also find that the HPols under-perform relative to the VPol channels. Our timing calibrated data is subsequently used to calibrate the ADC-to-Voltage conversion as well as precise antenna locations, as a precursor to vertex reconstruction. The calibrated data will then be analyzed for UHEN signals in the final step of data compression. The ability of A1 to scan the firn region of SP ice sheet will contribute greatly towards a 5-station analysis and will inform the design of the planned IceCube Gen-2 radio array.
△ Less
Submitted 14 August, 2023;
originally announced August 2023.
-
Deep learning-based statistical noise reduction for multidimensional spectral data
Authors:
Younsik Kim,
Dongjin Oh,
Soonsang Huh,
Dongjoon Song,
Sunbeom Jeong,
Junyoung Kwon,
Minsoo Kim,
Donghan Kim,
Hanyoung Ryu,
Jongkeun Jung,
Wonshik Kyung,
Byungmin Sohn,
Suyoung Lee,
Jounghoon Hyun,
Yeonghoon Lee,
Yeongkwan Kimand Changyoung Kim
Abstract:
In spectroscopic experiments, data acquisition in multi-dimensional phase space may require long acquisition time, owing to the large phase space volume to be covered. In such case, the limited time available for data acquisition can be a serious constraint for experiments in which multidimensional spectral data are acquired. Here, taking angle-resolved photoemission spectroscopy (ARPES) as an exa…
▽ More
In spectroscopic experiments, data acquisition in multi-dimensional phase space may require long acquisition time, owing to the large phase space volume to be covered. In such case, the limited time available for data acquisition can be a serious constraint for experiments in which multidimensional spectral data are acquired. Here, taking angle-resolved photoemission spectroscopy (ARPES) as an example, we demonstrate a denoising method that utilizes deep learning as an intelligent way to overcome the constraint. With readily available ARPES data and random generation of training data set, we successfully trained the denoising neural network without overfitting. The denoising neural network can remove the noise in the data while preserving its intrinsic information. We show that the denoising neural network allows us to perform similar level of second-derivative and line shape analysis on data taken with two orders of magnitude less acquisition time. The importance of our method lies in its applicability to any multidimensional spectral data that are susceptible to statistical noise.
△ Less
Submitted 2 July, 2021;
originally announced July 2021.
-
A Silicon Beam Tracker
Authors:
J. H. Han,
H. S. Ahn,
J. B. Bae,
H. J. Hyun,
S. W. Jung,
D. H. Kah,
C. H. Kim,
H. J. Kim,
K. C. Kim,
M. H. Lee,
L. Lutz,
A. Malinin,
H. Park,
S. Ryu,
E. S. Seo,
P. Walpole,
J. Wu,
J. H. Yoo,
Y. S. Yoon,
S. Y. Zinn
Abstract:
When testing and calibrating particle detectors in a test beam, accurate tracking information independent of the detector being tested is extremely useful during the offline analysis of the data. A general-purpose Silicon Beam Tracker (SBT) was constructed with an active area of 32.0 x 32.0 mm2 to provide this capability for the beam calibration of the Cosmic Ray Energetics And Mass (CREAM) calori…
▽ More
When testing and calibrating particle detectors in a test beam, accurate tracking information independent of the detector being tested is extremely useful during the offline analysis of the data. A general-purpose Silicon Beam Tracker (SBT) was constructed with an active area of 32.0 x 32.0 mm2 to provide this capability for the beam calibration of the Cosmic Ray Energetics And Mass (CREAM) calorimeter. The tracker consists of two modules, each comprised of two orthogonal layers of 380 μm thick silicon strip sensors. In one module each layer is a 64-channel AC-coupled single-sided silicon strip detector (SSD) with a 0.5 mm pitch. In the other, each layer is a 32-channel DC-coupled single-sided SSD with a 1.0 mm pitch. The signals from the 4 layers are read out using modified CREAM hodoscope front-end electronics with a USB 2.0 interface board to a Linux DAQ PC. In this paper, we present the construction of the SBT, along with its performance in radioactive source tests and in a CERN beam test in October 2006.
△ Less
Submitted 23 September, 2020;
originally announced September 2020.
-
Performance of the ISS-CREAM calorimeter in a calibration beam test
Authors:
H. G. Zhang,
D. Angelaszek,
M. Copley,
J. H. Han,
H. G. Huh,
Y. S. Hwang,
H. J. Hyun,
J. A. Jeon,
K. C. Kim,
M. H. Kim,
H. J. Kim,
K. Kwashnak,
H. Y. Lee,
J. Lee,
M. H. Lee,
J. Lundquist,
L. Lutz,
A. Malinin,
H. Park,
J. M. Park,
N. Picot-Clemente,
E. S. Seo,
J. Smith,
J. Wu,
Z. Y. Yin
, et al. (1 additional authors not shown)
Abstract:
The Cosmic Ray Energetics And Mass experiment for the International Space Station (ISS-CREAM) was installed on the ISS to measure high-energy cosmic-ray elemental spectra for the charge range $\rm Z=1$ to 26. The ISS-CREAM instrument includes a tungsten scintillating-fiber calorimeter preceded by a carbon target for energy measurements. The carbon target induces hadronic interactions, and showers…
▽ More
The Cosmic Ray Energetics And Mass experiment for the International Space Station (ISS-CREAM) was installed on the ISS to measure high-energy cosmic-ray elemental spectra for the charge range $\rm Z=1$ to 26. The ISS-CREAM instrument includes a tungsten scintillating-fiber calorimeter preceded by a carbon target for energy measurements. The carbon target induces hadronic interactions, and showers of secondary particles develop in the calorimeter. The energy deposition in the calorimeter is proportional to the particle energy.
As a predecessor to ISS-CREAM, the balloon-borne CREAM instrument was successfully flown seven times over Antarctica for a cumulative exposure of 191 days. The CREAM calorimeter demonstrated its capability to measure energies of cosmic-ray particles, and the ISS-CREAM calorimeter is expected to have a similar performance. Before the launch, an engineering-unit calorimeter was shipped to CERN for calibration and performance tests. This beam test included position, energy, and angle scans of electron and pion beams together with a high-voltage scan for calibration and characterization. Additionally, an attenuation effect in the scintillating fibers was studied. In this paper, beam test results, including corrections for the attenuation effect, are presented.
△ Less
Submitted 9 June, 2021; v1 submitted 21 April, 2020;
originally announced April 2020.
-
Automatic detection and segmentation of lumbar vertebra from X-ray images for compression fracture evaluation
Authors:
Kang Cheol Kim,
Hyun Cheol Cho,
Tae Jun Jang,
Jong Mun Choi,
Jin Keun Seo
Abstract:
For compression fracture detection and evaluation, an automatic X-ray image segmentation technique that combines deep-learning and level-set methods is proposed. Automatic segmentation is much more difficult for X-ray images than for CT or MRI images because they contain overlapping shadows of thoracoabdominal structures including lungs, bowel gases, and other bony structures such as ribs. Additio…
▽ More
For compression fracture detection and evaluation, an automatic X-ray image segmentation technique that combines deep-learning and level-set methods is proposed. Automatic segmentation is much more difficult for X-ray images than for CT or MRI images because they contain overlapping shadows of thoracoabdominal structures including lungs, bowel gases, and other bony structures such as ribs. Additional difficulties include unclear object boundaries, the complex shape of the vertebra, inter-patient variability, and variations in image contrast. Accordingly, a structured hierarchical segmentation method is presented that combines the advantages of two deep-learning methods. Pose-driven learning is used to selectively identify the five lumbar vertebra in an accurate and robust manner. With knowledge of the vertebral positions, M-net is employed to segment the individual vertebra. Finally, fine-tuning segmentation is applied by combining the level-set method with the previously obtained segmentation results. The performance of the proposed method was validated using clinical data, resulting in center position detection error of $25.35\pm10.86$ and a mean Dice similarity metric of $91.60\pm2.22\%$.
△ Less
Submitted 16 April, 2019;
originally announced April 2019.
-
Automatic evaluation of fetal head biometry from ultrasound images using machine learning
Authors:
Hwa Pyung Kim,
Sung Min Lee,
Ja-Young Kwon,
Yejin Park,
Kang Cheol Kim,
Jin Keun Seo
Abstract:
Ultrasound-based fetal biometric measurements, such as head circumference (HC) and biparietal diameter (BPD), are commonly used to evaluate the gestational age and diagnose fetal central nervous system (CNS) pathology. Since manual measurements are operator-dependent and time-consuming, there have been numerous researches on automated methods. However, existing automated methods still are not sati…
▽ More
Ultrasound-based fetal biometric measurements, such as head circumference (HC) and biparietal diameter (BPD), are commonly used to evaluate the gestational age and diagnose fetal central nervous system (CNS) pathology. Since manual measurements are operator-dependent and time-consuming, there have been numerous researches on automated methods. However, existing automated methods still are not satisfactory in terms of accuracy and reliability, owing to difficulties in dealing with various artifacts in ultrasound images. This paper focuses on fetal head biometry and develops a deep-learning-based method for estimating HC and BPD with a high degree of accuracy and reliability. The proposed method effectively identifies the head boundary by differentiating tissue image patterns with respect to the ultrasound propagation direction. The proposed method was trained with 102 labeled data set and tested to 70 ultrasound images. We achieved a success rate of 92.31% for HC and BPD estimations, and an accuracy of 87.14 % for the plane acceptance check.
△ Less
Submitted 18 August, 2018;
originally announced August 2018.
-
Measurements of cosmic-ray proton and helium spectra from the BESS-Polar long-duration balloon flights over Antarctica
Authors:
K. Abe,
H. Fuke,
S. Haino,
T. Hams,
M. Hasegawa,
A. Horikoshi,
A. Itazaki,
K. C. Kim,
T. Kumazawa,
A. Kusumoto,
M. H. Lee,
Y. Makida,
S. Matsuda,
Y. Matsukawa,
K. Matsumoto,
J. W. Mitchell,
Z. Myers,
J. Nishimura,
M. Nozaki,
R. Orito,
J. F. Ormes,
N. Picot-Clemente,
K. Sakai,
M. Sasaki,
E. S. Seo
, et al. (12 additional authors not shown)
Abstract:
The BESS-Polar Collaboration measured the energy spectra of cosmic-ray protons and helium during two long-duration balloon flights over Antarctica in December 2004 and December 2007, at substantially different levels of solar modulation. Proton and helium spectra probe the origin and propagation history of cosmic rays in the galaxy, and are essential to calculations of the expected spectra of cosm…
▽ More
The BESS-Polar Collaboration measured the energy spectra of cosmic-ray protons and helium during two long-duration balloon flights over Antarctica in December 2004 and December 2007, at substantially different levels of solar modulation. Proton and helium spectra probe the origin and propagation history of cosmic rays in the galaxy, and are essential to calculations of the expected spectra of cosmic-ray antiprotons, positrons, and electrons from interactions of primary cosmic-ray nuclei with the interstellar gas, and to calculations of atmospheric muons and neutrinos. We report absolute spectra at the top of the atmosphere for cosmic-ray protons in the kinetic energy range 0.2-160 GeV and helium nuclei 0.15-80 GeV/nucleon. The corresponding magnetic rigidity ranges are 0.6-160 GV for protons and 1.1-160 GV for helium. These spectra are compared to measurements from previous BESS flights and from ATIC-2, PAMELA, and AMS-02. We also report the ratio of the proton and helium fluxes from 1.1 GV to 160 GV and compare to ratios from PAMELA and AMS-02.
△ Less
Submitted 30 August, 2016; v1 submitted 3 June, 2015;
originally announced June 2015.
-
Beam test calibration of the balloon-borne imaging calorimeter for the CREAM experiment
Authors:
P. S. Marrocchesi,
H. S. Ahn,
M. G. Bagliesi,
A. Basti,
G. Bigongiari,
A. Castellina,
M. A. Ciocci,
A. Di Virgilio,
T. Lomtatze,
O. Ganel,
K. C. Kim,
M. H. Lee,
F. Ligabue,
L. Lutz,
P. Maestro,
A. Malinine,
M. Meucci,
V. Millucci,
F. Morsani,
E. S. Seo,
R. Sina,
J. Wu,
Y. S. Yoon,
R. Zei,
S. -Y. Zinn
Abstract:
CREAM (Cosmic Ray Energetics And Mass) is a multi-flight balloon mission designed to collect direct data on the elemental composition and individual energy spectra of cosmic rays. Two instrument suites have been built to be flown alternately on a yearly base. The tungsten/Sci-Fi imaging calorimeter for the second flight, scheduled for December 2005, was calibrated with electron and proton beams…
▽ More
CREAM (Cosmic Ray Energetics And Mass) is a multi-flight balloon mission designed to collect direct data on the elemental composition and individual energy spectra of cosmic rays. Two instrument suites have been built to be flown alternately on a yearly base. The tungsten/Sci-Fi imaging calorimeter for the second flight, scheduled for December 2005, was calibrated with electron and proton beams at CERN. A calibration procedure based on the study of the longitudinal shower profile is described and preliminary results of the beam test are presented.
△ Less
Submitted 24 July, 2005;
originally announced July 2005.