-
Injection and capture of antiprotons in a Penning-Malmberg trap using a drift tube accelerator and degrader foil
Authors:
C. Amsler,
H. Breuker,
M. Bumbar,
S. Chesnevskaya,
G. Costantini,
R. Ferragut,
M. Giammarchi,
A. Gligorova,
G. Gosta,
H. Higaki,
M. Hori,
E. D. Hunter,
C. Killian,
V. Kraxberger,
N. Kuroda,
A. Lanz,
M. Leali,
G. Maero,
C. Malbrunot,
V. Mascagna,
Y. Matsuda,
V. Maeckel,
S. Migliorati,
D. J. Murtagh,
Y. Nagata
, et al. (11 additional authors not shown)
Abstract:
The Antiproton Decelerator (AD) at CERN provides antiproton bunches with a kinetic energy of 5.3 MeV. The Extra-Low ENergy Antiproton ring at CERN, commissioned at the AD in 2018, now supplies a bunch of electron-cooled antiprotons at a fixed energy of 100 keV. The MUSASHI antiproton trap was upgraded by replacing the radio-frequency quadrupole decelerator with a pulsed drift tube to re-accelerate…
▽ More
The Antiproton Decelerator (AD) at CERN provides antiproton bunches with a kinetic energy of 5.3 MeV. The Extra-Low ENergy Antiproton ring at CERN, commissioned at the AD in 2018, now supplies a bunch of electron-cooled antiprotons at a fixed energy of 100 keV. The MUSASHI antiproton trap was upgraded by replacing the radio-frequency quadrupole decelerator with a pulsed drift tube to re-accelerate antiprotons and optimize the injection energy into the degrader foils. By increasing the beam energy to 119 keV, a cooled antiproton accumulation efficiency of (26 +- 6)% was achieved.
△ Less
Submitted 11 June, 2024; v1 submitted 14 March, 2024;
originally announced March 2024.
-
Upgrade of the positron system of the ASACUSA-Cusp experiment
Authors:
A. Lanz,
C. Amsler,
H. Breuker,
M. Bumbar,
S. Chesnevskaya,
G. Costantini,
R. Ferragut,
M. Giammarchi,
A. Gligorova,
G. Gosta,
H. Higaki,
E. D. Hunter,
C. Killian,
V. Kraxberger,
N. Kuroda,
M. Leali,
G. Maero,
C. Malbrunot,
V. Mascagna,
Y. Matsuda,
V. Mäckel,
S. Migliorati,
D. J. Murtagh,
A. Nanda,
L. Nowak
, et al. (13 additional authors not shown)
Abstract:
The ASACUSA-Cusp collaboration has recently upgraded the positron system to improve the production of antihydrogen. Previously, the experiment suffered from contamination of the vacuum in the antihydrogen production trap due to the transfer of positrons from the high pressure region of a buffer gas trap. This contamination reduced the lifetime of antiprotons. By adding a new positron accumulator a…
▽ More
The ASACUSA-Cusp collaboration has recently upgraded the positron system to improve the production of antihydrogen. Previously, the experiment suffered from contamination of the vacuum in the antihydrogen production trap due to the transfer of positrons from the high pressure region of a buffer gas trap. This contamination reduced the lifetime of antiprotons. By adding a new positron accumulator and therefore decreasing the number of transfer cycles, the contamination of the vacuum has been reduced. Further to this, a new rare gas moderator and buffer gas trap, previously used at the Aarhus University, were installed. Measurements from Aarhus suggested that the number of positrons could be increased by a factor of four in comparison to the old system used at CERN. This would mean a reduction of the time needed for accumulating a sufficient number of positrons (of the order of a few million) for an antihydrogen production cycle. Initial tests have shown that the new system yields a comparable number of positrons to the old system.
△ Less
Submitted 14 July, 2023; v1 submitted 12 July, 2023;
originally announced July 2023.
-
Slow positron production and storage for the ASACUSA-Cusp experiment
Authors:
D. J. Murtagh,
C. Amsler,
H. Breuker,
M. Bumbar,
S. Chesnevskaya,
G. Costantini,
R. Ferragut,
M. Giammarchi,
A. Gligorova,
G. Gosta,
H. Higaki,
E. D. Hunter,
C. Killian,
V. Kraxberger,
N. Kuroda,
A. Lanz,
M. Leali,
G. Maero,
C. Mal\-bru\-not,
V. Mascagna,
Y. Matsuda,
V. Mäckel,
S. Migliorati,
A. Nanda,
L. Nowak
, et al. (13 additional authors not shown)
Abstract:
The ASACUSA Cusp experiment requires the production of dense positron plasmas with a high repetition rate to produce a beam of antihydrogen. In this work, details of the positron production apparatus used for the first observation of the antihydrogen beam, and subsequent measurements are described in detail. This apparatus replaced the previous compact trap design resulting in an improvement in po…
▽ More
The ASACUSA Cusp experiment requires the production of dense positron plasmas with a high repetition rate to produce a beam of antihydrogen. In this work, details of the positron production apparatus used for the first observation of the antihydrogen beam, and subsequent measurements are described in detail. This apparatus replaced the previous compact trap design resulting in an improvement in positron accumulation by a factor of ($52\pm3)$
△ Less
Submitted 22 June, 2023;
originally announced June 2023.
-
SDR, EVC, and SDREVC: Limitations and Extensions
Authors:
E. D. Hunter,
C. Amsler,
H. Breuker,
M. Bumbar,
S. Chesnevskaya,
G. Costantini,
R. Ferragut,
M. Giammarchi,
A. Gligorova,
G. Gosta,
H. Higaki,
C. Killian,
V. Kraxberger,
N. Kuroda,
A. Lanz,
M. Leali,
G. Maero,
C. Malbrunot,
V. Mascagna,
Y. Matsuda,
V. Mäckel,
S. Migliorati,
D. J. Murtagh,
A. Nanda,
L. Nowak
, et al. (12 additional authors not shown)
Abstract:
Methods for reducing the radius, temperature, and space charge of nonneutral plasma are usually reported for conditions which approximate an ideal Penning Malmberg trap. Here we show that (1) similar methods are still effective under surprisingly adverse circumstances: we perform SDR and SDREVC in a strong magnetic mirror field using only 3 out of 4 rotating wall petals. In addition, we demonstrat…
▽ More
Methods for reducing the radius, temperature, and space charge of nonneutral plasma are usually reported for conditions which approximate an ideal Penning Malmberg trap. Here we show that (1) similar methods are still effective under surprisingly adverse circumstances: we perform SDR and SDREVC in a strong magnetic mirror field using only 3 out of 4 rotating wall petals. In addition, we demonstrate (2) an alternative to SDREVC, using e-kick instead of EVC and (3) an upper limit for how much plasma can be cooled to T < 20 K using EVC. This limit depends on the space charge, not on the number of particles or the plasma density.
△ Less
Submitted 3 June, 2023; v1 submitted 1 June, 2023;
originally announced June 2023.
-
Alignment of the CLAS12 central hybrid tracker with a Kalman Filter
Authors:
S. J. Paul,
A. Peck,
M. Arratia,
Y. Gotra,
V. Ziegler,
R. De Vita,
F. Bossu,
M. Defurne,
H. Atac,
C. Ayerbe Gayoso,
L. Baashen,
N. A. Baltzell,
L. Barion,
M. Bashkanov,
M. Battaglieri,
I. Bedlinskiy,
B. Benkel,
F. Benmokhtar,
A. Bianconi,
L. Biondo,
A. S. Biselli,
M. Bondi,
S. Boiarinov,
K. Th. Brinkmann,
W. J. Briscoe
, et al. (109 additional authors not shown)
Abstract:
Several factors can contribute to the difficulty of aligning the sensors of tracking detectors, including a large number of modules, multiple types of detector technologies, and non-linear strip patterns on the sensors. All three of these factors apply to the CLAS12 CVT, which is a hybrid detector consisting of planar silicon sensors with non-parallel strips, and cylindrical micromegas sensors wit…
▽ More
Several factors can contribute to the difficulty of aligning the sensors of tracking detectors, including a large number of modules, multiple types of detector technologies, and non-linear strip patterns on the sensors. All three of these factors apply to the CLAS12 CVT, which is a hybrid detector consisting of planar silicon sensors with non-parallel strips, and cylindrical micromegas sensors with longitudinal and arc-shaped strips located within a 5~T superconducting solenoid. To align this detector, we used the Kalman Alignment Algorithm, which accounts for correlations between the alignment parameters without requiring the time-consuming inversion of large matrices. This is the first time that this algorithm has been adapted for use with hybrid technologies, non-parallel strips, and curved sensors. We present the results for the first alignment of the CLAS12 CVT using straight tracks from cosmic rays and from a target with the magnetic field turned off. After running this procedure, we achieved alignment at the level of 10~$μ$m, and the widths of the residual spectra were greatly reduced. These results attest to the flexibility of this algorithm and its applicability to future use in the CLAS12 CVT and other hybrid or curved trackers, such as those proposed for the future Electron-Ion Collider.
△ Less
Submitted 9 August, 2022;
originally announced August 2022.
-
Upgrade of ASACUSA's Antihydrogen Detector
Authors:
V. Kraxberger,
C. Amsler,
H. Breuker,
S. Chesnevskaya,
G. Costantini,
R. Ferragut,
M. Giammarchi,
A. Gligorova,
G. Gosta,
H. Higaki,
E. D. Hunter,
C. Killian,
V. Kletzl,
N. Kuroda,
A. Lanz,
M. Leali,
V. Mäckel,
G. Maero,
C. Malbrunot,
V. Mascagna,
Y. Matsuda,
S. Migliorati,
D. J. Murtagh,
Y. Nagata,
A. Nanda
, et al. (13 additional authors not shown)
Abstract:
The goal of the ASACUSA (Atomic Spectroscopy And Collisions Using Slow Antiprotons) CUSP experiment at CERN's Antiproton Decelerator is to measure the ground state hyperfine splitting of antihydrogen in order to test whether CPT invariance is broken.
The ASACUSA hodoscope is a detector consisting of two layers of 32 plastic scintillator bars individually read out by two serially connected silico…
▽ More
The goal of the ASACUSA (Atomic Spectroscopy And Collisions Using Slow Antiprotons) CUSP experiment at CERN's Antiproton Decelerator is to measure the ground state hyperfine splitting of antihydrogen in order to test whether CPT invariance is broken.
The ASACUSA hodoscope is a detector consisting of two layers of 32 plastic scintillator bars individually read out by two serially connected silicon photo multipliers (SiPMs) on each end. Two additional layers for position resolution along the beam axis were scintillator fibres, which will now be replaced by scintillating tiles placed onto the existing bars and also read out by SiPMs. If the antiproton of antihydrogen annihilates in the center of the hodoscope, particles (mostly pions) are produced and travel through the various layers of the detector and produce signals.
The hodoscope was successfully used during the last data taking period at CERN. The necessary time resolution to discriminate between particles travelling through the detector from outside and particles produced in the center of the detector was achieved by the use of waveform digitisers and software constant fraction discrimination. The disadvantage of this readout scheme was the slow readout speed, which was improved by two orders of magnitude. This was done by omitting the digitisers and replacing them with TDCs reading out the digital time-over-threshold (ToT) signal using leading edge discrimination.
△ Less
Submitted 24 October, 2022; v1 submitted 25 April, 2022;
originally announced April 2022.
-
Cyclotron cooling to cryogenic temperature in a Penning-Malmberg trap with a large solid angle acceptance
Authors:
C. Amsler,
H. Breuker,
S. Chesnevskaya,
G. Costantini,
R. Ferragut,
M. Giammarchi,
A. Gligorova,
G. Gosta,
H. Higaki,
E. D. Hunter,
C. Killian,
V. Kletzl,
V. Kraxberger,
N. Kuroda,
A. Lanz,
M. Leali,
V. Mäckel,
G. Maero,
C. Malbrunot,
V. Mascagna,
Y. Matsuda,
S. Migliorati,
D. J. Murtagh,
Y. Nagata,
A. Nanda
, et al. (13 additional authors not shown)
Abstract:
Magnetized nonneutral plasma composed of electrons or positrons couples to the local microwave environment via cyclotron radiation. The equilibrium plasma temperature depends on the microwave energy density near the cyclotron frequency. Fine copper meshes and cryogenic microwave absorbing material were used to lower the effective temperature of the radiation environment in ASACUSA's Cusp trap, res…
▽ More
Magnetized nonneutral plasma composed of electrons or positrons couples to the local microwave environment via cyclotron radiation. The equilibrium plasma temperature depends on the microwave energy density near the cyclotron frequency. Fine copper meshes and cryogenic microwave absorbing material were used to lower the effective temperature of the radiation environment in ASACUSA's Cusp trap, resulting in significantly reduced plasma temperature.
△ Less
Submitted 28 March, 2022;
originally announced March 2022.
-
Minimizing plasma temperature for antimatter mixing experiments
Authors:
E. D. Hunter,
C. Amsler,
H. Breuker,
S. Chesnevskaya,
G. Costantini,
R. Ferragut,
M. Giammarchi,
A. Gligorova,
G. Gosta,
H. Higaki,
Y. Kanai,
C. Killian,
V. Kletzl,
V. Kraxberger,
N. Kuroda,
A. Lanz,
M. Leali,
V. Mäckel,
G. Maero,
C. Malbrunot,
V. Mascagna,
Y. Matsuda,
S. Migliorati,
D. J. Murtagh,
Y. Nagata
, et al. (15 additional authors not shown)
Abstract:
The ASACUSA collaboration produces a beam of antihydrogen atoms by mixing pure positron and antiproton plasmas in a strong magnetic field with a double cusp geometry. The positrons cool via cyclotron radiation inside the cryogenic trap. Low positron temperature is essential for increasing the fraction of antihydrogen atoms which reach the ground state prior to exiting the trap. Many experimental g…
▽ More
The ASACUSA collaboration produces a beam of antihydrogen atoms by mixing pure positron and antiproton plasmas in a strong magnetic field with a double cusp geometry. The positrons cool via cyclotron radiation inside the cryogenic trap. Low positron temperature is essential for increasing the fraction of antihydrogen atoms which reach the ground state prior to exiting the trap. Many experimental groups observe that such plasmas reach equilibrium at a temperature well above the temperature of the surrounding electrodes. This problem is typically attributed to electronic noise and plasma expansion, which heat the plasma. The present work reports anomalous heating far beyond what can be attributed to those two sources. The heating seems to be a result of the axially open trap geometry, which couples the plasma to the external (300 K) environment via microwave radiation.
△ Less
Submitted 2 February, 2022; v1 submitted 4 January, 2022;
originally announced January 2022.
-
A Direct Detection Search for Hidden Sector New Particles in the 3-60 MeV Mass Range
Authors:
A. Ahmidouch,
S. Davis,
A. Gasparian,
T. J. Hague,
S. Mtingwa,
R. Pedroni,
C. Ayerbe-Gayoso,
H. Bhatt,
B. Devkota,
J. Dunne,
D. Dutta,
L. El Fassi,
A. Karki,
P. Mohanmurthy,
C. Peng,
S. Ali,
X. Bai,
J. Boyd,
B. Dharmasena,
V. Gamage,
K. Gnanvo,
S. Jeffas,
S. Jian,
N. Liyanage,
H. Nguyen
, et al. (36 additional authors not shown)
Abstract:
In our quest to understand the nature of dark matter and discover its non-gravitational interactions with ordinary matter, we propose an experiment using a \pbo ~calorimeter to search for or set new limits on the production rate of i) hidden sector particles in the $3 - 60$ MeV mass range via their $e^+e^-$ decay (or $γγ$ decay with limited tracking), and ii) the hypothetical X17 particle, claimed…
▽ More
In our quest to understand the nature of dark matter and discover its non-gravitational interactions with ordinary matter, we propose an experiment using a \pbo ~calorimeter to search for or set new limits on the production rate of i) hidden sector particles in the $3 - 60$ MeV mass range via their $e^+e^-$ decay (or $γγ$ decay with limited tracking), and ii) the hypothetical X17 particle, claimed in multiple recent experiments. The search for these particles is motivated by new hidden sector models and dark matter candidates introduced to account for a variety of experimental and observational puzzles: the small-scale structure puzzle in cosmological simulations, anomalies such as the 4.2$σ$ disagreement between experiments and the standard model prediction for the muon anomalous magnetic moment, and the excess of $e^+e^-$ pairs from the $^8$Be M1 and $^4$He nuclear transitions to their ground states observed by the ATOMKI group. In these models, the $1 - 100$ MeV mass range is particularly well-motivated and the lower part of this range still remains unexplored. Our proposed direct detection experiment will use a magnetic-spectrometer-free setup (the PRad apparatus) to detect all three final state particles in the visible decay of a hidden sector particle allowing for an effective control of the background and will cover the proposed mass range in a single setting. The use of the well-demonstrated PRad setup allows for an essentially ready-to-run and uniquely cost-effective search for hidden sector particles in the $3 - 60$ MeV mass range with a sensitivity of 8.9$\times$10$^{-8}$ - 5.8$\times$10$^{-9}$ to $ε^2$, the square of the kinetic mixing interaction constant between hidden and visible sectors. This updated proposal includes our response to the PAC49 comments.
△ Less
Submitted 4 August, 2022; v1 submitted 30 August, 2021;
originally announced August 2021.
-
Measurement of the Principal Quantum Number Distribution in a Beam of Antihydrogen Atoms
Authors:
B. Kolbinger,
C. Amsler,
S. Arguedas Cuendis,
H. Breuker,
A. Capon,
G. Costantini,
P. Dupré,
M. Fleck,
A. Gligorova,
H. Higaki,
Y. Kanai,
V. Kletzl,
N. Kuroda,
A. Lanz,
M. Leali,
V. Mäckel,
C. Malbrunot,
V. Mascagna,
O. Massiczek,
Y. Matsuda,
D. J. Murtagh,
Y. Nagata,
A. Nanda,
L. Nowak,
B. Radics
, et al. (13 additional authors not shown)
Abstract:
The ASACUSA (Atomic Spectroscopy And Collisions Using Slow Antiprotons) collaboration plans to measure the ground-state hyperfine splitting of antihydrogen in a beam at the CERN Antiproton Decelerator with initial relative precision of 10-6 or better, to test the fundamental CPT (combination of charge conjugation, parity transformation and time reversal) symmetry between matter and antimatter. Thi…
▽ More
The ASACUSA (Atomic Spectroscopy And Collisions Using Slow Antiprotons) collaboration plans to measure the ground-state hyperfine splitting of antihydrogen in a beam at the CERN Antiproton Decelerator with initial relative precision of 10-6 or better, to test the fundamental CPT (combination of charge conjugation, parity transformation and time reversal) symmetry between matter and antimatter. This challenging goal requires a polarised antihydrogen beam with a sufficient number of antihydrogen atoms in the ground state. The first measurement of the quantum state distribution of antihydrogen atoms in a low magnetic field environment of a few mT is described. Furthermore, the data-driven machine learning analysis to identify antihydrogen events is discussed.
△ Less
Submitted 19 November, 2020; v1 submitted 10 August, 2020;
originally announced August 2020.
-
Antiproton beams with low energy spread for antihydrogen production
Authors:
M. Tajima,
N. Kuroda,
C. Amsler,
H. Breuker,
C. Evans,
M. Fleck,
A. Gligorova,
H. Higaki,
Y. Kanai,
B. Kolbinger,
A. Lanz,
M. Leali,
V. Mäckel,
C. Malbrunot,
V. Mascagna,
Y. Matsuda,
D. Murtagh,
Y. Nagata,
A. Nanda,
B. Radics,
M. Simon,
S. Ulmer,
L. Venturelli,
E. Widmann,
M. Wiesinger
, et al. (1 additional authors not shown)
Abstract:
A low energy antiproton transport from the ASACUSA antiproton accumulation trap (MUSASHI trap) to the antihydrogen production trap (double cusp trap) is developed. The longitudinal antiproton energy spread after the transport line is 0.23 +- 0.02 eV, compared with 15 eV with a previous method used in 2012. This reduction is achieved by an adiabatic transport beamline with several pulse-driven coax…
▽ More
A low energy antiproton transport from the ASACUSA antiproton accumulation trap (MUSASHI trap) to the antihydrogen production trap (double cusp trap) is developed. The longitudinal antiproton energy spread after the transport line is 0.23 +- 0.02 eV, compared with 15 eV with a previous method used in 2012. This reduction is achieved by an adiabatic transport beamline with several pulse-driven coaxial coils. Antihydrogen atoms are synthesized by directly injecting the antiprotons into a positron plasma, resulting in the higher production rate.
△ Less
Submitted 25 February, 2019;
originally announced February 2019.
-
A hydrogen beam to characterize the ASACUSA antihydrogen hyperfine spectrometer
Authors:
C. Malbrunot,
M. Diermaier,
M. C. Simon,
C. Amsler,
S. Arguedas Cuendis,
H. Breuker,
C. Evans,
M. Fleck,
B. Kolbinger,
A. Lanz,
M. Leali,
V. Maeckel,
V. Mascagna,
O. Massiczek,
Y. Matsuda,
Y. Nagata,
C. Sauerzopf,
L. Venturelli,
E. Widmann,
M. Wiesinger,
Y. Yamazaki,
J. Zmeskal
Abstract:
The antihydrogen programme of the ASACUSA collaboration at the antiproton decelerator of CERN focuses on Rabi-type measurements of the ground-state hyperfine splitting of antihydrogen for a test of the combined Charge-Parity-Time symmetry. The spectroscopy apparatus consists of a microwave cavity to drive hyperfine transitions and a superconducting sextupole magnet for quantum state analysis via S…
▽ More
The antihydrogen programme of the ASACUSA collaboration at the antiproton decelerator of CERN focuses on Rabi-type measurements of the ground-state hyperfine splitting of antihydrogen for a test of the combined Charge-Parity-Time symmetry. The spectroscopy apparatus consists of a microwave cavity to drive hyperfine transitions and a superconducting sextupole magnet for quantum state analysis via Stern-Gerlach separation. However, the small production rates of antihydrogen forestall comprehensive performance studies on the spectroscopy apparatus. For this purpose a hydrogen source and detector have been developed which in conjunction with ASACUSA's hyperfine spectroscopy equipment form a complete Rabi experiment. We report on the formation of a cooled, polarized, and time modulated beam of atomic hydrogen and its detection using a quadrupole mass spectrometer and a lock-in amplification scheme. In addition key features of ASACUSA's hyperfine spectroscopy apparatus are discussed.t
△ Less
Submitted 17 December, 2018;
originally announced December 2018.
-
Hyperfine spectroscopy of hydrogen and antihydrogen in ASACUSA
Authors:
E. Widmann,
C. Amsler,
S. Arguedas Cuendis,
H. Breuker,
M. Diermaier,
P. Dupré,
C. Evans,
M. Fleck,
A. Gligorova,
H. Higaki,
Y. Kanai,
B. Kolbinger,
N. Kuroda,
M. Leali,
A. M. M. Leite,
V. Mäckel,
C. Malbrunot,
V. Mascagna,
O. Massiczek,
Y. Matsuda,
D. J. Murtagh,
Y. Nagata,
A. Nanda,
D. Phan,
C. Sauerzopf
, et al. (9 additional authors not shown)
Abstract:
The ASACUSA collaboration at the Antiproton Decelerator of CERN aims at a precise measurement of the antihydrogen ground-state hyperfine structure as a test of the fundamental CPT symmetry. A beam of antihydrogen atoms is formed in a CUSP trap, undergoes Rabi-type spectroscopy and is detected downstream in a dedicated antihydrogen detector. In parallel measurements using a polarized hydrogen beam…
▽ More
The ASACUSA collaboration at the Antiproton Decelerator of CERN aims at a precise measurement of the antihydrogen ground-state hyperfine structure as a test of the fundamental CPT symmetry. A beam of antihydrogen atoms is formed in a CUSP trap, undergoes Rabi-type spectroscopy and is detected downstream in a dedicated antihydrogen detector. In parallel measurements using a polarized hydrogen beam are being performed to commission the spectroscopy apparatus and to perform measurements of parameters of the Standard Model Extension (SME). The current status of antihydrogen spectroscopy is reviewed and progress of ASACUSA is presented.
△ Less
Submitted 16 December, 2018; v1 submitted 4 September, 2018;
originally announced September 2018.
-
The ASACUSA antihydrogen and hydrogen program : results and prospects
Authors:
C. Malbrunot,
C. Amsler,
S. Arguedas Cuendi,
H. Breuker,
P. Dupre,
M. Fleck,
H. Higaki,
Y. Kanai,
T. Kobayashi,
B. Kolbinger,
N. Kuroda,
M. Leali,
V. Maeckel,
V. Mascagna,
O. Massiczek,
Y. Matsuda,
Y. Nagata,
M. C. Simon,
H. Spitzer,
M. Tajima,
S. Ulmer,
L. Venturelli,
E. Widmann,
M. Wiesinger,
Y. Yamazaki
, et al. (1 additional authors not shown)
Abstract:
The goal of the ASACUSA-CUSP collaboration at the Antiproton Decelerator of CERN is to measure the ground-state hyperfine splitting of antihydrogen using an atomic spectroscopy beamline. A milestone was achieved in 2012 through the detection of 80 antihydrogen atoms 2.7 meters away from their production region. This was the first observation of "cold" antihydrogen atoms in a magnetic field free re…
▽ More
The goal of the ASACUSA-CUSP collaboration at the Antiproton Decelerator of CERN is to measure the ground-state hyperfine splitting of antihydrogen using an atomic spectroscopy beamline. A milestone was achieved in 2012 through the detection of 80 antihydrogen atoms 2.7 meters away from their production region. This was the first observation of "cold" antihydrogen atoms in a magnetic field free region. In parallel to the progress on the antihydrogen production, the spectroscopy beamline was tested with a source of hydrogen. This led to a measurement at a relative precision of 2.7x 10^(-9) which constitues the most precise measurement of the hydrogen hyperfine splitting in a beam. Further measurements with an upgraded hydrogen apparatus are motivated by CPT and Lorentz violation tests in the framework of the Standard Model Extension. Unlike for hydrogen, the antihydrogen experiment is complicated by the difficulty of synthesizing enough cold antiatoms in ground-state. The first antihydrogen quantum states scan at the entrance of the spectroscopy apparatus was realized in 2016 and is presented here. The prospects for a ppm measurement are also discussed.
△ Less
Submitted 9 October, 2017;
originally announced October 2017.
-
Towards Measuring the Ground State Hyperfine Splitting of Antihydrogen -- A Progress Report
Authors:
C. Sauerzopf,
A. Capon,
M. Diermaier,
P. Dupré,
Y. Higashi,
C. Kaga,
B. Kolbinger,
M. Leali,
S. Lehner,
E. Lodi Rizzini,
C. Malbrunot,
V. Mascagna,
O. Massiczek,
D. J. Murtagh,
Y. Nagata,
B. Radics,
M. C. Simon,
K. Suzuki,
M. Tajima,
S. Ulmer,
S. Vamosi,
S. van Gorp,
J. Zmeskal,
H. Breuker,
H. Higaki
, et al. (6 additional authors not shown)
Abstract:
We report the successful commissioning and testing of a dedicated field-ioniser chamber for measuring principal quantum number distributions in antihydrogen as part of the ASACUSA hyperfine spectroscopy apparatus. The new chamber is combined with a beam normalisation detector that consists of plastic scintillators and a retractable passivated implanted planar silicon (PIPS) detector.
We report the successful commissioning and testing of a dedicated field-ioniser chamber for measuring principal quantum number distributions in antihydrogen as part of the ASACUSA hyperfine spectroscopy apparatus. The new chamber is combined with a beam normalisation detector that consists of plastic scintillators and a retractable passivated implanted planar silicon (PIPS) detector.
△ Less
Submitted 6 June, 2016;
originally announced June 2016.
-
About the importance of the nuclear recoil in αemission near the DNA
Authors:
E. Lodi Rizzini,
A. Bianconi,
M. Corradini,
M. Leali,
V. Mascagna,
L. Venturelli,
N. Zurlo
Abstract:
The effect of the energy deposition inside the human body made by radioactive substances is discussed. For the first time, we stress the importance of the recoiling nucleus in such reactions, particularly concerning the damage caused on the DNA structure.
The effect of the energy deposition inside the human body made by radioactive substances is discussed. For the first time, we stress the importance of the recoiling nucleus in such reactions, particularly concerning the damage caused on the DNA structure.
△ Less
Submitted 19 July, 2011;
originally announced July 2011.