A Wireless, Multicolor Fluorescence Image Sensor Implant for Real-Time Monitoring in Cancer Therapy
Authors:
Micah Roschelle,
Rozhan Rabbani,
Surin Gweon,
Rohan Kumar,
Alec Vercruysse,
Nam Woo Cho,
Matthew H. Spitzer,
Ali M. Niknejad,
Vladimir M. Stojanovic,
Mekhail Anwar
Abstract:
Real-time monitoring of dynamic biological processes in the body is critical to understanding disease progression and treatment response. This data, for instance, can help address the lower than 50% response rates to cancer immunotherapy. However, current clinical imaging modalities lack the molecular contrast, resolution, and chronic usability for rapid and accurate response assessments. Here, we…
▽ More
Real-time monitoring of dynamic biological processes in the body is critical to understanding disease progression and treatment response. This data, for instance, can help address the lower than 50% response rates to cancer immunotherapy. However, current clinical imaging modalities lack the molecular contrast, resolution, and chronic usability for rapid and accurate response assessments. Here, we present a fully wireless image sensor featuring a 2.5$\times$5 mm$^2$ CMOS integrated circuit for multicolor fluorescence imaging deep in tissue. The sensor operates wirelessly via ultrasound (US) at 5 cm depth in oil, harvesting energy with 221 mW/cm$^{2}$ incident US power density (31% of FDA limits) and backscattering data at 13 kbps with a bit error rate <$10^{-6}$. In-situ fluorescence excitation is provided by micro-laser diodes controlled with a programmable on-chip driver. An optical frontend combining a multi-bandpass interference filter and a fiber optic plate provides >6 OD excitation blocking and enables three-color imaging for detecting multiple cell types. A 36$\times$40-pixel array captures images with <125 $μ$m resolution. We demonstrate wireless, dual-color fluorescence imaging of both effector and suppressor immune cells in ex vivo mouse tumor samples with and without immunotherapy. These results show promise for providing rapid insight into therapeutic response and resistance, guiding personalized medicine.
△ Less
Submitted 27 June, 2024;
originally announced June 2024.
-
Companding algorithm for the detection of malignant lesions in HDR CT mandibular images
Authors:
Yuval Tamir,
Hedva Spitzer,
Noam Yarom,
Yuval Barkan,
Silvina Friedlander Barenboim,
Alex Dobriyan
Abstract:
Compressing and expanding (companding) HDR computerized tomography (CT) images to a single LDR image is still a relevant challenge. Besides the general need for simplification of the window setting method for the purpose of diagnosis, there are specific clinical needs for the resection of malignant lesions in the mandible, for example, where the lesions may exist in both the soft tissue and the bo…
▽ More
Compressing and expanding (companding) HDR computerized tomography (CT) images to a single LDR image is still a relevant challenge. Besides the general need for simplification of the window setting method for the purpose of diagnosis, there are specific clinical needs for the resection of malignant lesions in the mandible, for example, where the lesions may exist in both the soft tissue and the bone. A successful medical algorithm has to take into account the requirement to variously expose the same range of specific gray levels, when they are presented by different body tissues. As a solution, we propose an adaptive multi-scale contrast companding (AMCC) algorithm that is implemented by using soft threshold separation to two channels (bone and soft tissue). This separation is determined by the HU intensity values (that are already computed in the algorithm) in the specific resolution that is best fitted to the teeth. Each channel contains different set of parameters. The AMCC algorithm successfully and adaptively compands a large variety of mandibular CT HDR images as well as natural images. Two collaborating physicians who evaluated tumor boundaries, by the 'single presentation' method, reported that 92% of the algorithm output images were at least as useful for diagnosis as those in the window method, while 50% of the algorithm output images were better. When each slice was evaluated simultaneously, by the window setting method (bone and soft tissue) and algorithm output images, 93% of the evaluations declared a preference for the output images of the algorithm. We describe here a low-cost method for companding the HDR images with the ability to facilitate resections of mandibular lesions by providing optimal boundary definition.
△ Less
Submitted 30 March, 2020;
originally announced March 2020.
-
Hyperfine spectroscopy of hydrogen and antihydrogen in ASACUSA
Authors:
E. Widmann,
C. Amsler,
S. Arguedas Cuendis,
H. Breuker,
M. Diermaier,
P. Dupré,
C. Evans,
M. Fleck,
A. Gligorova,
H. Higaki,
Y. Kanai,
B. Kolbinger,
N. Kuroda,
M. Leali,
A. M. M. Leite,
V. Mäckel,
C. Malbrunot,
V. Mascagna,
O. Massiczek,
Y. Matsuda,
D. J. Murtagh,
Y. Nagata,
A. Nanda,
D. Phan,
C. Sauerzopf
, et al. (9 additional authors not shown)
Abstract:
The ASACUSA collaboration at the Antiproton Decelerator of CERN aims at a precise measurement of the antihydrogen ground-state hyperfine structure as a test of the fundamental CPT symmetry. A beam of antihydrogen atoms is formed in a CUSP trap, undergoes Rabi-type spectroscopy and is detected downstream in a dedicated antihydrogen detector. In parallel measurements using a polarized hydrogen beam…
▽ More
The ASACUSA collaboration at the Antiproton Decelerator of CERN aims at a precise measurement of the antihydrogen ground-state hyperfine structure as a test of the fundamental CPT symmetry. A beam of antihydrogen atoms is formed in a CUSP trap, undergoes Rabi-type spectroscopy and is detected downstream in a dedicated antihydrogen detector. In parallel measurements using a polarized hydrogen beam are being performed to commission the spectroscopy apparatus and to perform measurements of parameters of the Standard Model Extension (SME). The current status of antihydrogen spectroscopy is reviewed and progress of ASACUSA is presented.
△ Less
Submitted 16 December, 2018; v1 submitted 4 September, 2018;
originally announced September 2018.
-
The ASACUSA antihydrogen and hydrogen program : results and prospects
Authors:
C. Malbrunot,
C. Amsler,
S. Arguedas Cuendi,
H. Breuker,
P. Dupre,
M. Fleck,
H. Higaki,
Y. Kanai,
T. Kobayashi,
B. Kolbinger,
N. Kuroda,
M. Leali,
V. Maeckel,
V. Mascagna,
O. Massiczek,
Y. Matsuda,
Y. Nagata,
M. C. Simon,
H. Spitzer,
M. Tajima,
S. Ulmer,
L. Venturelli,
E. Widmann,
M. Wiesinger,
Y. Yamazaki
, et al. (1 additional authors not shown)
Abstract:
The goal of the ASACUSA-CUSP collaboration at the Antiproton Decelerator of CERN is to measure the ground-state hyperfine splitting of antihydrogen using an atomic spectroscopy beamline. A milestone was achieved in 2012 through the detection of 80 antihydrogen atoms 2.7 meters away from their production region. This was the first observation of "cold" antihydrogen atoms in a magnetic field free re…
▽ More
The goal of the ASACUSA-CUSP collaboration at the Antiproton Decelerator of CERN is to measure the ground-state hyperfine splitting of antihydrogen using an atomic spectroscopy beamline. A milestone was achieved in 2012 through the detection of 80 antihydrogen atoms 2.7 meters away from their production region. This was the first observation of "cold" antihydrogen atoms in a magnetic field free region. In parallel to the progress on the antihydrogen production, the spectroscopy beamline was tested with a source of hydrogen. This led to a measurement at a relative precision of 2.7x 10^(-9) which constitues the most precise measurement of the hydrogen hyperfine splitting in a beam. Further measurements with an upgraded hydrogen apparatus are motivated by CPT and Lorentz violation tests in the framework of the Standard Model Extension. Unlike for hydrogen, the antihydrogen experiment is complicated by the difficulty of synthesizing enough cold antiatoms in ground-state. The first antihydrogen quantum states scan at the entrance of the spectroscopy apparatus was realized in 2016 and is presented here. The prospects for a ppm measurement are also discussed.
△ Less
Submitted 9 October, 2017;
originally announced October 2017.