-
A proposal for a low-frequency axion search in the 1-2 $μ$eV range and below with the BabyIAXO magnet
Authors:
S. Ahyoune,
A. Álvarez Melcón,
S. Arguedas Cuendis,
S. Calatroni,
C. Cogollos,
J. Devlin,
A. Díaz-Morcillo,
D. Díez-Ibáñez,
B. Döbrich,
J. Galindo,
J. D. Gallego,
J. M. García-Barceló,
B. Gimeno,
J. Golm,
Y. Gu,
L. Herwig,
I. G. Irastorza,
A. J. Lozano-Guerrero,
C. Malbrunot,
J. Miralda-Escudé,
J. Monzó-Cabrera,
P. Navarro,
J. R. Navarro-Madrid,
J. Redondo,
J. Reina-Valero
, et al. (5 additional authors not shown)
Abstract:
In the near future BabyIAXO will be the most powerful axion helioscope, relying on a custom-made magnet of two bores of 70 cm diameter and 10 m long, with a total available magnetic volume of more than 7 m$^3$. In this document, we propose and describe the implementation of low-frequency axion haloscope setups suitable for operation inside the BabyIAXO magnet. The RADES proposal has a potential se…
▽ More
In the near future BabyIAXO will be the most powerful axion helioscope, relying on a custom-made magnet of two bores of 70 cm diameter and 10 m long, with a total available magnetic volume of more than 7 m$^3$. In this document, we propose and describe the implementation of low-frequency axion haloscope setups suitable for operation inside the BabyIAXO magnet. The RADES proposal has a potential sensitivity to the axion-photon coupling $g_{aγ}$ down to values corresponding to the KSVZ model, in the (currently unexplored) mass range between 1 and 2$~μ$eV, after a total effective exposure of 440 days. This mass range is covered by the use of four differently dimensioned 5-meter-long cavities, equipped with a tuning mechanism based on inner turning plates. A setup like the one proposed would also allow an exploration of the same mass range for hidden photons coupled to photons. An additional complementary apparatus is proposed using LC circuits and exploring the low energy range ($\sim10^{-4}-10^{-1}~μ$eV). The setup includes a cryostat and cooling system to cool down the BabyIAXO bore down to about 5 K, as well as appropriate low-noise signal amplification and detection chain.
△ Less
Submitted 22 November, 2023; v1 submitted 29 June, 2023;
originally announced June 2023.
-
Methods and restrictions to increase the volume of resonant rectangular-section haloscopes for detecting dark matter axions
Authors:
J. M. García-Barceló,
A. Álvarez Melcón,
A. Díaz-Morcillo,
B. Gimeno,
A. J. Lozano-Guerrero,
J. Monzo-Cabrera,
J. R. Navarro-Madrid,
P. Navarro
Abstract:
Haloscopes are resonant cavities that serve as detectors of dark matter axions when they are immersed in a strong static magnetic field. In order to increase the volume and improve its introduction within dipole or solenoid magnets for axion searches, various haloscope design techniques for rectangular geometries are discussed in this study. The volume limits of two types of haloscopes are explore…
▽ More
Haloscopes are resonant cavities that serve as detectors of dark matter axions when they are immersed in a strong static magnetic field. In order to increase the volume and improve its introduction within dipole or solenoid magnets for axion searches, various haloscope design techniques for rectangular geometries are discussed in this study. The volume limits of two types of haloscopes are explored: based on single cavities and based on multicavities. For both cases, possibilities for increasing the volume in long and/or tall structures are presented. For multicavities, 1D geometries are explored to optimize the space in the magnets. Also, 2D and 3D geometries are introduced as a first step for laying the foundations for the development of these kind of topologies. The results prove the usefulness of the developed methods, evidencing the ample room of improvement in rectangular haloscope designs nowadays. A factor of three orders of magnitude improvement in volume compared with a single cavity based on WR-90 standard waveguide is obtained with the design of a long and tall single cavity. Similar procedures have been applied for long and tall multicavities. Experimental measurements are shown for prototypes based on tall multicavities and 2D structures, demonstrating the feasibility of using these types of geometries to increase the volume in real haloscopes.
△ Less
Submitted 24 February, 2023; v1 submitted 21 February, 2023;
originally announced February 2023.
-
The Canfranc Axion Detection Experiment (CADEx): Search for axions at 90 GHz with Kinetic Inductance Detectors
Authors:
Beatriz Aja,
Sergio Arguedas Cuendis,
Ivan Arregui,
Eduardo Artal,
R. Belén Barreiro,
Francisco J. Casas,
Maria C. de Ory,
Alejandro Díaz-Morcillo,
Luisa de la Fuente,
Juan Daniel Gallego,
José María García-Barceló,
Benito Gimeno,
Alicia Gomez,
Daniel Granados,
Bradley J. Kavanagh,
Miguel A. G. Laso,
Txema Lopetegi,
Antonio José Lozano-Guerrero,
Maria T. Magaz,
Jesús Martín-Pintado,
Enrique Martínez-González,
Jordi Miralda-Escudé,
Juan Monzó-Cabrera,
Jose R. Navarro-Madrid,
Ana B. Nuñez Chico
, et al. (11 additional authors not shown)
Abstract:
We propose a novel experiment, the Canfranc Axion Detection Experiment (CADEx), to probe dark matter axions with masses in the range 330-460 $μ$eV, within the W-band (80-110 GHz), an unexplored parameter space in the well-motivated dark matter window of Quantum ChromoDynamics (QCD) axions. The experimental design consists of a microwave resonant cavity haloscope in a high static magnetic field cou…
▽ More
We propose a novel experiment, the Canfranc Axion Detection Experiment (CADEx), to probe dark matter axions with masses in the range 330-460 $μ$eV, within the W-band (80-110 GHz), an unexplored parameter space in the well-motivated dark matter window of Quantum ChromoDynamics (QCD) axions. The experimental design consists of a microwave resonant cavity haloscope in a high static magnetic field coupled to a highly sensitive detecting system based on Kinetic Inductance Detectors via optimized quasi-optics (horns and mirrors). The experiment is in preparation and will be installed in the dilution refrigerator of the Canfranc Underground Laboratory. Sensitivity forecasts for axion detection with CADEx, together with the potential of the experiment to search for dark photons, are presented.
△ Less
Submitted 6 June, 2022;
originally announced June 2022.
-
On the use of ferroelectric material in the detection of dark matter axions
Authors:
J. M. García Barceló,
A. Álvarez Melcón,
S. Arguedas Cuendis,
A. Díaz-Morcillo,
B. Gimeno,
A. Kanareykin,
A. J. Lozano-Guerrero,
P. Navarro,
W. Wuensch
Abstract:
Tuning is an essential requirement for the search of dark matter axions employing haloscopes since its mass is not known yet to the scientific community. At the present day, most haloscope tuning systems are based on mechanical devices which can lead to failures due to the complexity of the environment in which they are used. However, the electronic tuning making use of ferroelectric materials can…
▽ More
Tuning is an essential requirement for the search of dark matter axions employing haloscopes since its mass is not known yet to the scientific community. At the present day, most haloscope tuning systems are based on mechanical devices which can lead to failures due to the complexity of the environment in which they are used. However, the electronic tuning making use of ferroelectric materials can provide a path that is less vulnerable to mechanical failures and thus complements and expands current tuning systems. In this work, we present and design a novel concept for using the ferroelectric Potassium Tantalate ($KTaO_3$ or KTO) material as a tuning element in haloscopes based on coupled microwave cavities. In this line, the structures used in the Relic Axion Detector Exploratory Setup (RADES) group are based on several cavities that are connected by metallic irises, which act as interresonator coupling elements. In this article, we also show how to use these $KTaO_3$ films as interresonator couplings between cavities, instead of inductive or capacitive metallic windows used in the past. These two concepts represent a crucial upgrade over the current systems employed in the dark matter axions community, achieving a tuning range of $2.23 \, \%$ which represents a major improvement as compared to previous works ($<0.1 \, \%$) for the same class of tuning systems. The theoretical and simulated results shown in this work demonstrate the interest of the novel concepts proposed for the incorporation of this kind of ferroelectric media in multicavity resonant haloscopes in the search for dark matter axions.
△ Less
Submitted 7 December, 2022; v1 submitted 25 April, 2022;
originally announced April 2022.
-
Design of new resonant haloscopes in the search for the darkmatter axion: a review of the first steps in the RADES collaboration
Authors:
A. Díaz-Morcillo,
J. M. García Barceló,
A. J. Lozano-Guerrero,
P. Navarro,
B. Gimeno,
S. Arguedas Cuendis,
A. Álvarez Melcón,
C. Cogollos,
S. Calatroni,
B. Döbrich,
J. D. Gallego,
J. Golm,
I. G. Irastorza,
C. Malbrunot,
Jordi Miralda-Escudé,
C. Peña Garay,
J. Redondo,
W. Wuensch
Abstract:
Within the increasing interest in the dark matter axion detection through haloscopes, in which different international groups are currently involved, the RADES group was established in 2016 with the goal of developing very sensitive detection systems to be operated in dipole magnets. This review deals with the work developed by this collaboration during its first five years, from the first designs…
▽ More
Within the increasing interest in the dark matter axion detection through haloscopes, in which different international groups are currently involved, the RADES group was established in 2016 with the goal of developing very sensitive detection systems to be operated in dipole magnets. This review deals with the work developed by this collaboration during its first five years, from the first designs, based on the multi-cavity concept, aiming to increase the haloscope volume and, so, to improve its sensitivity, their evolution, the data acquisition design, and, finally, the first experimental run. Moreover, the envisaged work within RADES, for both dipole and solenoid magnets, in the short and medium term is also presented.
△ Less
Submitted 22 January, 2022; v1 submitted 29 November, 2021;
originally announced November 2021.
-
The 3 cavity prototypes of RADES, an axion detector using microwave filters at CAST
Authors:
S. Arguedas Cuendis,
A. Álvarez Melcón,
C. Cogollos,
A. Díaz-Morcillo,
B. Döbrich,
J. D. Gallego,
B. Gimeno,
I. G. Irastorza,
A. J. Lozano-Guerrero,
C. Malbrunot,
P. Navarro,
C. Peña Garay,
J. Redondo,
T. Vafeiadis,
W. Wuensch
Abstract:
The Relic Axion Detector Experimental Setup (RADES) is an axion search project that uses a microwave filter as resonator for Dark Matter conversion. The main focus of this publication is the description of the 3 different cavity prototypes of RADES. The result of the first tests of one of the prototypes is also presented. The filters consist of 5 or 6 stainless steel sub-cavities joined by rectang…
▽ More
The Relic Axion Detector Experimental Setup (RADES) is an axion search project that uses a microwave filter as resonator for Dark Matter conversion. The main focus of this publication is the description of the 3 different cavity prototypes of RADES. The result of the first tests of one of the prototypes is also presented. The filters consist of 5 or 6 stainless steel sub-cavities joined by rectangular irises. The size of the sub-cavities determines the working frequency, the amount of sub-cavities determine the working volume. The first cavity prototype was built in 2017 to work at a frequency of $\sim$ 8.4 GHz and it was placed at the 9 T CAST dipole magnet at CERN. Two more prototypes were designed and built in 2018. The aim of the new designs is to find and test the best cavity geometry in order to scale up in volume and to introduce an effective tuning mechanism. Our results demonstrate the promising potential of this type of filter to reach QCD axion sensitivity at X-Band frequencies.
△ Less
Submitted 11 March, 2019;
originally announced March 2019.