-
Increasing the rate capability for the cryogenic stopping cell of the FRS Ion Catcher
Authors:
J. W. Zhao,
D. Amanbayev,
T. Dickel,
I. Miskun,
W. R. Plass,
N. Tortorelli,
S. Ayet San Andres,
Soenke Beck,
J. Bergmann,
Z. Brencic,
P. Constantin,
H. Geissel,
F. Greiner,
L. Groef,
C. Hornung,
N. Kuzminzuk,
G. Kripko-Koncz,
I. Mardor,
I. Pohjalainen,
C. Scheidenberger,
P. G. Thirolf,
S. Bagchi,
E. Haettner,
E. Kazantseva,
D. Kostyleva
, et al. (23 additional authors not shown)
Abstract:
At the FRS Ion Catcher (FRS-IC), projectile and fission fragments are produced at relativistic energies, separated in-flight, energy-bunched, slowed down, and thermalized in the ultra-pure helium gas-filled cryogenic stopping cell (CSC). Thermalized nuclei are extracted from the CSC using a combination of DC and RF electric fields and gas flow. This CSC also serves as the prototype CSC for the Sup…
▽ More
At the FRS Ion Catcher (FRS-IC), projectile and fission fragments are produced at relativistic energies, separated in-flight, energy-bunched, slowed down, and thermalized in the ultra-pure helium gas-filled cryogenic stopping cell (CSC). Thermalized nuclei are extracted from the CSC using a combination of DC and RF electric fields and gas flow. This CSC also serves as the prototype CSC for the Super-FRS, where exotic nuclei will be produced at unprecedented rates making it possible to go towards the extremes of the nuclear chart. Therefore, it is essential to efficiently extract thermalized exotic nuclei from the CSC under high beam rate conditions, in order to use the rare exotic nuclei which come as cocktail beams. The extraction efficiency dependence on the intensity of the impinging beam into the CSC was studied with a primary beam of 238U and its fragments. Tests were done with two different versions of the DC electrode structure inside the cryogenic chamber, the standard 1 m long and a short 0.5 m long DC electrode. In contrast to the rate capability of 10^4 ions/s with the long DC electrode, results show no extraction efficiency loss up to the rate of 2x10^5 ions/s with the new short DC electrode. This order of magnitude increase of the rate capability paves the way for new experiments at the FRS-IC, including exotic nuclei studies with in-cell multi-nucleon transfer reactions. The results further validate the design concept of the CSC for the Super-FRS, which was developed to effectively manage beams of even higher intensities.
△ Less
Submitted 4 August, 2023;
originally announced August 2023.
-
Separation of atomic and molecular ions by ion mobility with an RF carpet
Authors:
Ivan Miskun,
Timo Dickel,
Samuel Ayet San Andres,
Julian Bergmann,
Paul Constantin,
Jens Ebert,
Hans Geissel,
Florian Greiner,
Emma Haettner,
Christine Hornung,
Wayne Lippert,
Israel Mardor,
Iain Moore,
Wolfgang R. Plaß,
Sivaji Purushothaman,
Ann-Kathrin Rink,
Moritz P. Reiter,
Christoph Scheidenberger,
Helmut Weick
Abstract:
Gas-filled stopping cells are used at accelerator laboratories for the thermalization of high-energy radioactive ion beams. Common challenges of many stopping cells are a high molecular background of extracted ions and limitations of extraction efficiency due to space-charge effects. At the FRS Ion Catcher at GSI, a new technique for removal of ionized molecules prior to their extraction out of th…
▽ More
Gas-filled stopping cells are used at accelerator laboratories for the thermalization of high-energy radioactive ion beams. Common challenges of many stopping cells are a high molecular background of extracted ions and limitations of extraction efficiency due to space-charge effects. At the FRS Ion Catcher at GSI, a new technique for removal of ionized molecules prior to their extraction out of the stopping cell has been developed. This technique utilizes the RF carpet for the separation of atomic ions from molecular contaminant ions through their difference in ion mobility. Results from the successful implementation and test during an experiment with a 600~MeV/u $^{124}$Xe primary beam are presented. Suppression of molecular contaminants by three orders of magnitude has been demonstrated. Essentially background-free measurement conditions with less than $1~\%$ of background events within a mass-to-charge range of 25 u/e have been achieved. The technique can also be used to reduce the space-charge effects at the extraction nozzle and in the downstream beamline, thus ensuring high efficiency of ion transport and highly-accurate measurements under space-charge-free conditions.
△ Less
Submitted 6 November, 2020; v1 submitted 27 July, 2020;
originally announced July 2020.
-
High-resolution, accurate MR-TOF-MS for short-lived, exotic nuclei of few events in their ground and low-lying isomeric states
Authors:
S. Ayet,
C. Hornung,
J. Ebert,
W. R. Plaß,
T. Dickel,
H. Geissel,
C. Scheidenberger,
J. Bergmann,
F. Greiner,
E. Haettner,
C. Jesch,
W. Lippert,
I. Mardor,
I. Miskun,
Z. Patyk,
S. Pietri,
A. Pihktelev,
S. Purushothaman,
M. P. Reiter,
A. -K. Rink,
H. Weick,
M. I. Yavor,
S. Bagchi,
V. Charviakova,
P. Constantin
, et al. (15 additional authors not shown)
Abstract:
Mass measurements of fission and projectile fragments, produced via $^{238}$U and $^{124}$Xe primary beams, have been performed with the multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS) of the FRS Ion Catcher with a mass resolving powers (FWHM) up to 410,000 and an uncertainty of $6\cdot 10^{-8}$. The nuclides were produced and separated in-flight with the fragment separator FRS at…
▽ More
Mass measurements of fission and projectile fragments, produced via $^{238}$U and $^{124}$Xe primary beams, have been performed with the multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS) of the FRS Ion Catcher with a mass resolving powers (FWHM) up to 410,000 and an uncertainty of $6\cdot 10^{-8}$. The nuclides were produced and separated in-flight with the fragment separator FRS at 300 to 1000 MeV/u and thermalized in a cryogenic stopping cell. The data-analysis procedure was developed to determine with highest accuracy the mass values and the corresponding uncertainties for the most challenging conditions: down to a few events in a spectrum and overlapping distributions, characterized only by a broader common peak shape. With this procedure, the resolution of low-lying isomers is increased by a factor of up to three compared to standard data analysis. The ground-state masses of 31 short-lived nuclides of 15 different elements with half-lives down to 17.9~ms and count rates as low as 11 events per nuclide were determined. This is the first direct mass measurement for seven nuclides. The excitation energies and the isomer-to-ground state ratios of six isomeric states with excitation energies down to about 280~keV were measured. For nuclides with known mass values, the average relative deviation from the literature values is $(2.9 \pm 6.2) \cdot 10^{-8}$. The measured two-neutron separation energies and their slopes near and at the N=126 and Z=82 shell closures indicate a strong element-dependent binding energy of the first neutron above the closed proton shell Z=82. The experimental results deviate strongly from the theoretical predictions, especially for N=126 and N=127.
△ Less
Submitted 31 January, 2019;
originally announced January 2019.
-
The Soreq Applied Research Accelerator Facility (SARAF) - Overview, Research Programs and Future Plans
Authors:
Israel Mardor,
Ofer Aviv,
Marilena Avrigeanu,
Dan Berkovits,
Adi Dahan,
Timo Dickel,
Ilan Eliyahu,
Moshe Gai,
Inbal Gavish-Segev,
Shlomi Halfon,
Michael Hass,
Tsviki Hirsh,
Boaz Kaiser,
Daniel Kijel,
Arik Kreisel,
Yonatan Mishnayot,
Ish Mukul,
Ben Ohayon,
Michael Paul,
Amichay Perry,
Hitesh Rahangdale,
Jacob Rodnizki,
Guy Ron,
Revital Sasson-Zukran,
Asher Shor
, et al. (4 additional authors not shown)
Abstract:
The Soreq Applied Research Accelerator Facility (SARAF) is under construction in the Soreq Nuclear Research Center at Yavne, Israel. When completed at the beginning of the next decade, SARAF will be a user facility for basic and applied nuclear physics, based on a 40 MeV, 5 mA CW proton/deuteron superconducting linear accelerator. Phase I of SARAF (SARAF-I, 4 MeV, 2 mA CW protons, 5 MeV 1 mA CW de…
▽ More
The Soreq Applied Research Accelerator Facility (SARAF) is under construction in the Soreq Nuclear Research Center at Yavne, Israel. When completed at the beginning of the next decade, SARAF will be a user facility for basic and applied nuclear physics, based on a 40 MeV, 5 mA CW proton/deuteron superconducting linear accelerator. Phase I of SARAF (SARAF-I, 4 MeV, 2 mA CW protons, 5 MeV 1 mA CW deuterons) is already in operation, generating scientific results in several fields of interest. The main ongoing program at SARAF-I is the production of 30 keV neutrons and measurement of Maxwellian Averaged Cross Sections (MACS), important for the astrophysical s-process. The world leading Maxwellian epithermal neutron yield at SARAF-I ($5\times 10^{10}$ epithermal neutrons/sec), generated by a novel Liquid-Lithium Target (LiLiT), enables improved precision of known MACSs, and new measurements of low-abundance and radioactive isotopes. Research plans for SARAF-II span several disciplines: Precision studies of beyond-Standard-Model effects by trapping light exotic radioisotopes, such as $^6$He, $^8$Li and $^{18,19,23}$Ne, in unprecedented amounts (including meaningful studies already at SARAF-I); extended nuclear astrophysics research with higher energy neutrons, including generation and studies of exotic neutron-rich isotopes relevant to the rapid (r-) process; nuclear structure of exotic isotopes; high energy neutron cross sections for basic nuclear physics and material science research, including neutron induced radiation damage; neutron based imaging and therapy; and novel radiopharmaceuticals development and production. In this paper we present a technical overview of SARAF-I and II, including a description of the accelerator and its irradiation targets; a survey of existing research programs at SARAF-I; and the research potential at the completed facility (SARAF-II).
△ Less
Submitted 23 January, 2018; v1 submitted 19 January, 2018;
originally announced January 2018.
-
High-power liquid-lithium jet target for neutron production
Authors:
S. Halfon,
A. Arenshtam,
D. Kijel,
M. Paul,
D. Berkovits,
I. Eliyahu,
G. Feinberg,
M. Friedman,
N. Hazenshprung,
I. Mardor,
A. Nagler,
G. Shimel,
M. Tessler,
I. Silverman
Abstract:
A compact Liquid-Lithium Target (LiLiT) was built and tested with a high-power electron gun at Soreq Nuclear Research Center. The lithium target, to be bombarded by the high-intensity proton beam of the Soreq Applied Research Accelerator Facility (SARAF), will constitute an intense source of neutrons produced by the 7Li(p,n)7Be reaction for nuclear astrophysics research and as a pilot setup for ac…
▽ More
A compact Liquid-Lithium Target (LiLiT) was built and tested with a high-power electron gun at Soreq Nuclear Research Center. The lithium target, to be bombarded by the high-intensity proton beam of the Soreq Applied Research Accelerator Facility (SARAF), will constitute an intense source of neutrons produced by the 7Li(p,n)7Be reaction for nuclear astrophysics research and as a pilot setup for accelerator-based Boron Neutron Capture Therapy (BNCT). The liquid-lithium jet target acts both as neutron-producing target and beam dump by removing the beam thermal power (>5 kW, >1 MW/cm3) with fast transport. The target was designed based on a thermal model, accompanied by a detailed calculation of the 7Li(p,n) neutron yield, energy distribution and angular distribution. Liquid lithium is circulated through the target loop at ~200oC and generates a stable 1.5 mm-thick film flowing at a velocity up to 7 m/s onto a concave supporting wall. Electron beam irradiation demonstrated that the liquid-lithium target can dissipate electron power areal densities of > 4 kW/cm2 and volume power density of ~ 2 MW/cm3 at a lithium flow of ~4 m/s while maintaining stable temperature and vacuum conditions. The LiLiT setup is presently in online commissioning stage for high-intensity proton beam irradiation (1.91- 2.5 MeV, 1-2 mA) at SARAF.
△ Less
Submitted 30 November, 2013; v1 submitted 13 November, 2013;
originally announced November 2013.
-
Proof of principle of a high-spatial-resolution, resonant-response gamma-ray detector for Gamma Resonance Absorption in 14N
Authors:
M. Brandis,
M. B. Goldberg,
D. Vartsky,
E. Friedman,
I. Kreslo,
I. Mardor,
V. Dangendorf,
S. Levi,
I. Mor,
D. Bar
Abstract:
The development of a mm-spatial-resolution, resonant-response detector based on a micrometric glass capillary array filled with liquid scintillator is described. This detector was developed for Gamma Resonance Absorption (GRA) in 14N. GRA is an automatic-decision radiographic screening technique that combines high radiation penetration (the probe is a 9.17 MeV gamma ray) with very good sensitivity…
▽ More
The development of a mm-spatial-resolution, resonant-response detector based on a micrometric glass capillary array filled with liquid scintillator is described. This detector was developed for Gamma Resonance Absorption (GRA) in 14N. GRA is an automatic-decision radiographic screening technique that combines high radiation penetration (the probe is a 9.17 MeV gamma ray) with very good sensitivity and specificity to nitrogenous explosives. Detailed simulation of the detector response to electrons and protons generated by the 9.17 MeV gamma-rays was followed by a proof-of-principle experiment, using a mixed gamma-ray and neutron source. Towards this, a prototype capillary detector was assembled, including the associated filling and readout systems. Simulations and experimental results indeed show that proton tracks are distinguishable from electron tracks at relevant energies, on the basis of a criterion that combines track length and light intensity per unit length.
△ Less
Submitted 16 March, 2011;
originally announced March 2011.
-
Time-resolved fast neutron imaging: simulation of detector performance
Authors:
D. Vartsky,
I. Mor,
M. B. Goldberg,
I. Mardor,
G. Feldman,
D. Bar,
A. Shor,
V. Dangendorf,
G. Laczko,
A. Breskin,
R. Chechik
Abstract:
We have analyzed and compared the performance of two novel fast-neutron imaging methods with time-of-flight spectroscopy capability. Using MCNP and GEANT code simulations of neutron and charged-particle transport in the detectors, key parameters such as detection efficiency, the amount of energy deposited in the converter and the spatial resolution of both detector variants have been evaluated.
We have analyzed and compared the performance of two novel fast-neutron imaging methods with time-of-flight spectroscopy capability. Using MCNP and GEANT code simulations of neutron and charged-particle transport in the detectors, key parameters such as detection efficiency, the amount of energy deposited in the converter and the spatial resolution of both detector variants have been evaluated.
△ Less
Submitted 17 August, 2004;
originally announced August 2004.