Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content

Showing 1–7 of 7 results for author: Mardor, I

Searching in archive physics. Search in all archives.
.
  1. arXiv:2308.02224  [pdf, other

    physics.ins-det nucl-ex

    Increasing the rate capability for the cryogenic stopping cell of the FRS Ion Catcher

    Authors: J. W. Zhao, D. Amanbayev, T. Dickel, I. Miskun, W. R. Plass, N. Tortorelli, S. Ayet San Andres, Soenke Beck, J. Bergmann, Z. Brencic, P. Constantin, H. Geissel, F. Greiner, L. Groef, C. Hornung, N. Kuzminzuk, G. Kripko-Koncz, I. Mardor, I. Pohjalainen, C. Scheidenberger, P. G. Thirolf, S. Bagchi, E. Haettner, E. Kazantseva, D. Kostyleva , et al. (23 additional authors not shown)

    Abstract: At the FRS Ion Catcher (FRS-IC), projectile and fission fragments are produced at relativistic energies, separated in-flight, energy-bunched, slowed down, and thermalized in the ultra-pure helium gas-filled cryogenic stopping cell (CSC). Thermalized nuclei are extracted from the CSC using a combination of DC and RF electric fields and gas flow. This CSC also serves as the prototype CSC for the Sup… ▽ More

    Submitted 4 August, 2023; originally announced August 2023.

  2. arXiv:2007.14467  [pdf, other

    physics.ins-det nucl-ex

    Separation of atomic and molecular ions by ion mobility with an RF carpet

    Authors: Ivan Miskun, Timo Dickel, Samuel Ayet San Andres, Julian Bergmann, Paul Constantin, Jens Ebert, Hans Geissel, Florian Greiner, Emma Haettner, Christine Hornung, Wayne Lippert, Israel Mardor, Iain Moore, Wolfgang R. Plaß, Sivaji Purushothaman, Ann-Kathrin Rink, Moritz P. Reiter, Christoph Scheidenberger, Helmut Weick

    Abstract: Gas-filled stopping cells are used at accelerator laboratories for the thermalization of high-energy radioactive ion beams. Common challenges of many stopping cells are a high molecular background of extracted ions and limitations of extraction efficiency due to space-charge effects. At the FRS Ion Catcher at GSI, a new technique for removal of ionized molecules prior to their extraction out of th… ▽ More

    Submitted 6 November, 2020; v1 submitted 27 July, 2020; originally announced July 2020.

    Comments: 8 pages, 4 figures

  3. arXiv:1901.11278  [pdf, other

    nucl-ex physics.ins-det

    High-resolution, accurate MR-TOF-MS for short-lived, exotic nuclei of few events in their ground and low-lying isomeric states

    Authors: S. Ayet, C. Hornung, J. Ebert, W. R. Plaß, T. Dickel, H. Geissel, C. Scheidenberger, J. Bergmann, F. Greiner, E. Haettner, C. Jesch, W. Lippert, I. Mardor, I. Miskun, Z. Patyk, S. Pietri, A. Pihktelev, S. Purushothaman, M. P. Reiter, A. -K. Rink, H. Weick, M. I. Yavor, S. Bagchi, V. Charviakova, P. Constantin , et al. (15 additional authors not shown)

    Abstract: Mass measurements of fission and projectile fragments, produced via $^{238}$U and $^{124}$Xe primary beams, have been performed with the multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS) of the FRS Ion Catcher with a mass resolving powers (FWHM) up to 410,000 and an uncertainty of $6\cdot 10^{-8}$. The nuclides were produced and separated in-flight with the fragment separator FRS at… ▽ More

    Submitted 31 January, 2019; originally announced January 2019.

    Journal ref: Phys. Rev. C 99, 064313 (2019)

  4. arXiv:1801.06493  [pdf

    physics.ins-det nucl-ex

    The Soreq Applied Research Accelerator Facility (SARAF) - Overview, Research Programs and Future Plans

    Authors: Israel Mardor, Ofer Aviv, Marilena Avrigeanu, Dan Berkovits, Adi Dahan, Timo Dickel, Ilan Eliyahu, Moshe Gai, Inbal Gavish-Segev, Shlomi Halfon, Michael Hass, Tsviki Hirsh, Boaz Kaiser, Daniel Kijel, Arik Kreisel, Yonatan Mishnayot, Ish Mukul, Ben Ohayon, Michael Paul, Amichay Perry, Hitesh Rahangdale, Jacob Rodnizki, Guy Ron, Revital Sasson-Zukran, Asher Shor , et al. (4 additional authors not shown)

    Abstract: The Soreq Applied Research Accelerator Facility (SARAF) is under construction in the Soreq Nuclear Research Center at Yavne, Israel. When completed at the beginning of the next decade, SARAF will be a user facility for basic and applied nuclear physics, based on a 40 MeV, 5 mA CW proton/deuteron superconducting linear accelerator. Phase I of SARAF (SARAF-I, 4 MeV, 2 mA CW protons, 5 MeV 1 mA CW de… ▽ More

    Submitted 23 January, 2018; v1 submitted 19 January, 2018; originally announced January 2018.

    Comments: 32 pages, 31 figures, 10 tables, submitted as an invited review to European Physics Journal A

    Journal ref: Eur. Phys. J. A (2018) 54: 91

  5. arXiv:1311.3325  [pdf

    physics.ins-det nucl-ex

    High-power liquid-lithium jet target for neutron production

    Authors: S. Halfon, A. Arenshtam, D. Kijel, M. Paul, D. Berkovits, I. Eliyahu, G. Feinberg, M. Friedman, N. Hazenshprung, I. Mardor, A. Nagler, G. Shimel, M. Tessler, I. Silverman

    Abstract: A compact Liquid-Lithium Target (LiLiT) was built and tested with a high-power electron gun at Soreq Nuclear Research Center. The lithium target, to be bombarded by the high-intensity proton beam of the Soreq Applied Research Accelerator Facility (SARAF), will constitute an intense source of neutrons produced by the 7Li(p,n)7Be reaction for nuclear astrophysics research and as a pilot setup for ac… ▽ More

    Submitted 30 November, 2013; v1 submitted 13 November, 2013; originally announced November 2013.

    Comments: Accepted for publication in Rev. Sci. Instr

  6. Proof of principle of a high-spatial-resolution, resonant-response gamma-ray detector for Gamma Resonance Absorption in 14N

    Authors: M. Brandis, M. B. Goldberg, D. Vartsky, E. Friedman, I. Kreslo, I. Mardor, V. Dangendorf, S. Levi, I. Mor, D. Bar

    Abstract: The development of a mm-spatial-resolution, resonant-response detector based on a micrometric glass capillary array filled with liquid scintillator is described. This detector was developed for Gamma Resonance Absorption (GRA) in 14N. GRA is an automatic-decision radiographic screening technique that combines high radiation penetration (the probe is a 9.17 MeV gamma ray) with very good sensitivity… ▽ More

    Submitted 16 March, 2011; originally announced March 2011.

    Comments: 18 pages, 16 figures

    Journal ref: M Brandis et al 2011 JINST 6 P02008

  7. arXiv:physics/0408076  [pdf

    physics.ins-det physics.comp-ph

    Time-resolved fast neutron imaging: simulation of detector performance

    Authors: D. Vartsky, I. Mor, M. B. Goldberg, I. Mardor, G. Feldman, D. Bar, A. Shor, V. Dangendorf, G. Laczko, A. Breskin, R. Chechik

    Abstract: We have analyzed and compared the performance of two novel fast-neutron imaging methods with time-of-flight spectroscopy capability. Using MCNP and GEANT code simulations of neutron and charged-particle transport in the detectors, key parameters such as detection efficiency, the amount of energy deposited in the converter and the spatial resolution of both detector variants have been evaluated.

    Submitted 17 August, 2004; originally announced August 2004.