Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content

Showing 1–32 of 32 results for author: Dangendorf, V

Searching in archive physics. Search in all archives.
.
  1. arXiv:1812.09536  [pdf, ps, other

    physics.ins-det nucl-ex

    Time Projection Chamber (TPC) Detectors for Nuclear Astrophysics Studies With Gamma Beams

    Authors: M. Gai, D. Schweitzer, S. R. Stern, A. H. Young, R. Smith, M. Cwiok, J. S. Bihalowicz, H. Czyrkowski, R. Dabrowski, W. Dominik, A. Fijalkowska, Z. Janas, L. Janiak, A. Korgul, T. Matulewicz, C. Mazzocchi, M. Pfuetzner, M. Zaremba, D. Balabanski, I. Gheorghe, C. Matei, O. Tesileanu, N. V. Zamfir, M. W. Ahmed, S. S. Henshaw , et al. (11 additional authors not shown)

    Abstract: Gamma-Beams at the HIgS facility in the USA and anticipated at the ELI-NP facility, now constructed in Romania, present unique new opportunities to advance research in nuclear astrophysics; not the least of which is resolving open questions in oxygen formation during stellar helium burning via a precise measurement of the 12C(a,g) reaction. Time projection chamber (TPC) detectors operating with lo… ▽ More

    Submitted 22 December, 2018; originally announced December 2018.

    Comments: Contribution Symposium on Radiation Measurements and Applications (SORMA XVII), June 11 - June 14 , 2018, University of Michigan, Ann Arbor

    Report number: UConn-40870-XXXX

  2. arXiv:1706.07689  [pdf

    physics.geo-ph physics.ins-det

    A method for rapid determination of oil and water content in geological formations

    Authors: D. Vartsky, M. B. Goldberg, V. Dangendorf, I. Israelashvili, I. Mor, D. Bar, K. Tittelmeier, M. Weierganz, B. Bromberger, A. Breskin

    Abstract: A novel method utilizing Fast Neutron Resonance Transmission Radiography is proposed for rapid, non-destructive and quantitative determination of the weight fractions of oil and water in cores taken from subterranean or underwater geological formations. Its ability to distinguish water from oil stems from the unambiguously-specific energy-dependence of the neutron cross-sections for the principal… ▽ More

    Submitted 22 June, 2017; originally announced June 2017.

    Comments: 11 pages, 7 figures. arXiv admin note: text overlap with arXiv:1602.06533

  3. arXiv:1602.06533  [pdf

    physics.geo-ph physics.ins-det

    Quantitative discrimination between oil and water in drilled bore cores via fast-neutron resonance transmission radiography

    Authors: D. Vartsky, M. B. Goldberg, V. Dangendorf, I. Israelashvili, I. Mor, D. Bar, K. Tittelmeier, M. Weierganz, A. Breskin

    Abstract: A novel method based on Fast Neutron Resonance Transmission Radiography is proposed for non-destructive, quantitative determination of the weight percentages of oil and water in cores taken from subterranean or underwater geological formations. The ability of the method to distinguish water from oil stems from the unambiguously-specific energy dependence of the neutron cross-sections for the princ… ▽ More

    Submitted 21 February, 2016; originally announced February 2016.

    Comments: 16 pages, 10 figures, patent pending

  4. arXiv:1504.01919  [pdf

    physics.ins-det

    Time-resolved fast-neutron radiography of air-water two-phase flows in a rectangular channel by an improved detection system

    Authors: Robert Zboray, Volker Dangendorf, Ilan Mor, Benjamin Bromberger, Kai Tittelmeier

    Abstract: In a previous work we have demonstrated the feasibility of high-frame-rate, fast-neutron radiography of generic air-water two-phase flows in a 1.5 cm thick, rectangular flow channel. The experiments have been carried out at the high-intensity, white-beam facility of the Physikalisch-Technische Bundesanstalt, Germany, using an multi-frame, time-resolved detector developed for fast neutron resonance… ▽ More

    Submitted 8 April, 2015; originally announced April 2015.

    Comments: submitted to Review of Scientific Instruments, Apr. 2015

  5. arXiv:1504.01914  [pdf

    physics.ins-det

    High-frame rate, fast neutron imaging of two-phase flow in a thin rectangular channel

    Authors: R. Zboray, I. Mor, V. Dangendorf, M. Stark, K. Tittelmeier, M. Cortesi, R. Adams

    Abstract: We have demonstrated the feasibility of performing high-frame-rate, fast neutron radiography of air-water two-phase flows in a thin channel with rectangular cross section. The experiments have been carried out at the accelerator facility of the Physikalisch-Technische Bundesanstalt. A polychromatic, high-intensity fast neutron beam with average energy of 6 MeV was produced by 11.5 MeV deuterons hi… ▽ More

    Submitted 8 April, 2015; originally announced April 2015.

    Journal ref: Applied Radiation and Isotopes 90 page 122 1994

  6. arXiv:1502.00077  [pdf

    physics.ins-det

    Time-resolved neutron imaging at ANTARES cold neutron beamline

    Authors: A. S. Tremsin, V. Dangendorf, K. Tittelmeier, B. Schillinger, M. Schulz, M. Lerche, W. B. Feller

    Abstract: In non-destructive evaluation with X-rays light elements embedded in dense, heavy (or high-Z) matrices show little contrast and their structural details can hardly be revealed. Neutron radiography, on the other hand, provides a solution for those cases, in particular for hydrogenous materials, owing to the large neutron scattering cross section of hydrogen and uncorrelated dependency of neutron cr… ▽ More

    Submitted 31 January, 2015; originally announced February 2015.

  7. Parameters Affecting Temporal Resolution of Time Resolved Integrative Optical Neutron Detector (TRION)

    Authors: I. Mor, D. Vartsky, V. Dangendorf, D. Bar, G. Feldman, M. B. Goldberg, K. Tittelmeier, B. Bromberger, M. Brandis, M. Weierganz

    Abstract: The Time-Resolved Integrative Optical Neutron (TRION) detector was developed for Fast Neutron Resonance Radiography (FNRR), a fast-neutron transmission imaging method that exploits characteristic energy-variations of the total scattering cross-section in the En = 1-10 MeV range to detect specific elements within a radiographed object. As opposed to classical event-counting time of flight (ECTOF),… ▽ More

    Submitted 12 November, 2013; originally announced November 2013.

    Comments: Pre-print, also appears at JINST KEYWORDS: Fast neutron detectors; Plastic scintillator; Neutron radiography; Time-of-flight spectroscopy; Detection of explosives; Image intensifier; Pulsed Fast Neutron Transmission Spectroscopy (PFNTS); Fast Neutron Resonance Radiography (FNRR); Simulation

  8. arXiv:1303.4326  [pdf, ps, other

    nucl-ex astro-ph.SR nucl-th physics.ins-det

    Unambiguous Identification of the Second 2+ State in 12C and the Structure of the Hoyle State

    Authors: W. R. Zimmerman, M. W. Ahmed, B. Bromberger, S. C. Stave, A. Breskin, V. Dangendorf, Th. Delbar, M. Gai, S. S. Henshaw, J. M. Mueller, C. Sun, K. Tittelmeier, H. R. Weller, Y. K. Wu

    Abstract: The second 2+ state of 12C, predicted over fifty years ago as an excitation of the Hoyle state, has been unambiguously identified using the 12C(g,a_0)8Be reaction. The alpha particles produced by the photodisintegration of 12C were detected using an Optical Time Projection Chamber (O-TPC). Data were collected at beam energies between 9.1 and 10.7 MeV using the intense nearly mono-energetic gamma-r… ▽ More

    Submitted 18 March, 2013; originally announced March 2013.

    Comments: Accepted for Publication in the Physical Review Letter

    Report number: UConn-40870-00XX

  9. First studies of electron transport along small gas gaps of novel foil radiation converters for fast-neutron detectors

    Authors: M. Cortesi, R. Zboray, R. Adams, V. Dangendorf, A. Breskin, S. Mayer, H. Hoedlmoser, H. -M. Prasser

    Abstract: Novel high efficiency fast-neutron detectors were suggested for fan-beam tomography applications. They combine multi-layer polymer converters in gas medium, coupled to thick gaseous electron multipliers (THGEM). In this work we discuss the results of a systematic study of the electron transport inside a narrow gap between successive converter foils, which affects the performance of the detector, b… ▽ More

    Submitted 19 December, 2012; v1 submitted 26 October, 2012; originally announced October 2012.

    Comments: 19 pages, 18 figures, Journal of Instrumentation (JINST)

  10. Concept of a novel fast neutron imaging detector based on THGEM for fan-beam tomography applications

    Authors: M. Cortesi, R. Zboray, R. Adams, V. Dangendorf, H. -M. Prasser

    Abstract: The conceptual design and operational principle of a novel high-efficiency, fast neutron imaging detector based on THGEM, intended for future fan-beam transmission tomography applications, is described. We report on a feasibility study based on theoretical modeling and computer simulations of a possible detector configuration prototype. In particular we discuss results regarding the optimization o… ▽ More

    Submitted 1 March, 2012; originally announced March 2012.

    Comments: 11 Pages; 6 Figures; Proceeding of the International Workshop on Fast Neutron Detectors and Application FNDA2011, Ein Gedi, Israel, November 2011. Published on the Journal of Instrumentation; 2012 JINST 7 C02056

  11. arXiv:1201.2559  [pdf

    physics.ins-det nucl-ex

    Time and position sensitive single photon detector for scintillator read-out

    Authors: Sven Schössler, Benjamin Bromberger, Michal Brandis, Lothar Ph. H. Schmidt, Kai Tittelmeier, Achim Czasch, Volker Dangendorf, Ottmar Jagutzki

    Abstract: We have developed a photon counting detector system for combined neutron and gamma radiography which can determine position, time and intensity of a secondary photon flash created by a high-energy particle or photon within a scintillator screen. The system is based on a micro-channel plate photomultiplier concept utilizing image charge coupling to a position- and time-sensitive read-out anode plac… ▽ More

    Submitted 10 February, 2012; v1 submitted 12 January, 2012; originally announced January 2012.

    Comments: Proceedings of FNDA 2011

  12. Proof of principle of a high-spatial-resolution, resonant-response gamma-ray detector for Gamma Resonance Absorption in 14N

    Authors: M. Brandis, M. B. Goldberg, D. Vartsky, E. Friedman, I. Kreslo, I. Mardor, V. Dangendorf, S. Levi, I. Mor, D. Bar

    Abstract: The development of a mm-spatial-resolution, resonant-response detector based on a micrometric glass capillary array filled with liquid scintillator is described. This detector was developed for Gamma Resonance Absorption (GRA) in 14N. GRA is an automatic-decision radiographic screening technique that combines high radiation penetration (the probe is a 9.17 MeV gamma ray) with very good sensitivity… ▽ More

    Submitted 16 March, 2011; originally announced March 2011.

    Comments: 18 pages, 16 figures

    Journal ref: M Brandis et al 2011 JINST 6 P02008

  13. arXiv:1101.1940  [pdf

    physics.ins-det astro-ph.IM astro-ph.SR nucl-ex

    An Optical Readout TPC (O-TPC) for Studies in Nuclear Astrophysics With Gamma-Ray Beams at HIgS

    Authors: M. Gai, M. W. Ahmed, S. C. Stave, W. R. Zimmerman, A. Breskin, B. Bromberger, R. Chechik, V. Dangendorf, Th. Delbar, R. H. France III, S. S. Henshaw, T. J. Kading, P. P. Martel, J. E. R. McDonald, P. -N. Seo, K. Tittelmeier, H. R. Weller, A. H. Young

    Abstract: We report on the construction, tests, calibrations and commissioning of an Optical Readout Time Projection Chamber (O-TPC) detector operating with a CO2(80%) + N2(20%) gas mixture at 100 and 150 Torr. It was designed to measure the cross sections of several key nuclear reactions involved in stellar evolution. In particular, a study of the rate of formation of oxygen and carbon during the process o… ▽ More

    Submitted 10 January, 2011; originally announced January 2011.

    Comments: Supported by the Richard F. Goodman Yale-Weizmann Exchange Program, ACWIS, NY, and USDOE grant Numbers: DE-FG02-94ER40870 and DE-FG02-97ER41033

    Journal ref: Published in: JINST 5(2010)12004

  14. arXiv:1002.1622  [pdf

    physics.ins-det nucl-ex

    Development of an LED reference light source for calibration of radiographic imaging detectors

    Authors: M. Weierganz, D. Bar, B. Bromberger, V. Dangendorf, G. Feldman, M. B. Goldberg, M. Lindemann, I. Mor, K. Tittelmeier, D. Vartsky

    Abstract: A stable reference light source based on an LED (Light Emission Diode) is presented for stabilizing the conversion gain of the opto-electronic system of a gamma- and fast-neutron radiographic and tomographic imaging device. A constant fraction of the LED light is transported to the image plane of the camera and provides a stable reference exposure. This is used to normalize the images during off… ▽ More

    Submitted 8 February, 2010; originally announced February 2010.

  15. arXiv:0905.4399  [pdf

    physics.ins-det physics.acc-ph physics.atom-ph physics.optics

    High Spatial Resolution Fast-Neutron Imaging Detectors for Pulsed Fast-Neutron Transmission Spectroscopy

    Authors: I. Mor, D. Vartsky, D. Bar, G. Feldman, M. B. Goldberg, D. Katz, E. Sayag, I. Shmueli, Y. Cohen, A. Tal, Z. Vagish, B. Bromberger, V. Dangendorf, D. Mugai, K. Tittelmeier, M. Weierganz

    Abstract: Two generations of a novel detector for high-resolution transmission imaging and spectrometry of fast-neutrons are presented. These devices are based on a hydrogenous fiber scintillator screen and single- or multiple-gated intensified camera systems (ICCD). This detector is designed for energy-selective neutron radiography with nanosecond-pulsed broad-energy (1 - 10 MeV) neutron beams. Utilizing… ▽ More

    Submitted 27 May, 2009; originally announced May 2009.

    Comments: Also published in JINST: http://www.iop.org/EJ/abstract/1748-0221/4/05/P05016

  16. THGEM operation in Ne and Ne/CH4

    Authors: M. Cortesi, V. Peskov, G. Bartesaghi, J. Miyamoto, S. Cohen, R. Chechik, J. M. Maia, J. M. F. dos Santos, G. Gambarini, V. Dangendorf, A. Breskin

    Abstract: The operation of Thick Gaseous Electron Multipliers (THGEM) in Ne and Ne/CH4 mixtures, features high multiplication factors at relatively low operation potentials, in both single- and double-THGEM configurations. We present some systematic data measured with UV-photons and soft x-rays, in various Ne mixtures. It includes gain dependence on hole diameter and gas purity, photoelectron extraction e… ▽ More

    Submitted 19 May, 2009; v1 submitted 18 May, 2009; originally announced May 2009.

    Comments: Submitted to JINST, 25 pages, 33 figures

    Journal ref: JINST 4:P08001,2009

  17. Signal and Noise Analysis in TRION -Time-Resolved Integrative Optical Fast Neutron Detector

    Authors: D. Vartsky, G. Feldman, I. Mor, M. B. Goldberg, D. Bar, V. Dangendorf

    Abstract: TRION is a sub-mm spatial resolution fast neutron imaging detector, which employs an integrative optical time-of-flight technique. The detector was developed for fast neutron resonance radiography, a method capable of detecting a broad range of conventional and improvised explosives. In this study we have analyzed in detail, using Monte-Carlo calculations and experimentally determined parameters… ▽ More

    Submitted 24 December, 2008; originally announced December 2008.

    Comments: 18 pages

    Journal ref: JINST 4:P02001,2009

  18. A concise review on THGEM detectors

    Authors: A. Breskin, R. Alon, M. Cortesi, R. Chechik, J. Miyamoto, V. Dangendorf, J. Maia, J. M. F. Dos Santos

    Abstract: We briefly review the concept and properties of the Thick GEM (THGEM); it is a robust, high-gain gaseous electron multiplier, manufactured economically by standard printed-circuit drilling and etching technology. Its operation and structure resemble that of GEMs but with 5 to 20-fold expanded dimensions. The millimeter-scale hole-size results in good electron transport and in large avalanche-mul… ▽ More

    Submitted 13 July, 2008; originally announced July 2008.

    Comments: 8 pages, 11 figures; Invited Review at INSTR08, Novosibirsk, Feb 28-March 5 2008

    Journal ref: Nucl.Instrum.Meth.A598:107-111,2009

  19. Operation of a Thick Gas Electron Multiplier (THGEM) in Ar, Xe and Ar-Xe

    Authors: R. Alon, J. Miyamoto, M. Cortesi, A. Breskin, R. Chechik, I. Carne, J. M. Maia, J. M. F. dos Santos, M. Gai, D. McKinsey, V. Dangendorf

    Abstract: We present the results of our recent studies of a Thick Gaseous Electron Multiplier (THGEM)-based detector, operated in Ar, Xe and Ar:Xe (95:5) at various gas pressures. Avalanche-multiplication properties and energy resolution were investigated with soft x-rays for different detector configurations and parameters. Gains above 10E4 were reached in a double-THGEM detector, at atmospheric pressure… ▽ More

    Submitted 26 December, 2007; v1 submitted 4 December, 2007; originally announced December 2007.

    Comments: 19 pages, 17 figures, published in JINST

  20. Investigations of a THGEM-based imaging detector

    Authors: M. Cortesi, R. Alon, R. Chechik, A. Breskin, D. Vartsky, V. Dangendorf

    Abstract: We present the results of our recent studies on a Thick Gas Electron Multiplier (THGEM)-based imaging detector prototype. It consists of two 100x100 mm^2 THGEM electrodes in cascade, coupled to a resistive anode. The event location is recorded with a 2D double-sided readout electrode equipped with discrete delay-lines and dedicated electronics. The THGEM electrodes, produced by standard printed-… ▽ More

    Submitted 26 December, 2007; v1 submitted 22 July, 2007; originally announced July 2007.

    Comments: Published in JINST, 22 pages, 18 figures

    Journal ref: JINST2:P09002,2007

  21. arXiv:physics/0703211  [pdf

    physics.ins-det

    A Compact High-Energy Neutron Spectrometer

    Authors: F. D. Brooks, A. Buffler, M. S. Allie, M. S. Herbert, M. R. Nchodu, D. T. L. Jones, F. D. Smit, R. Nolte, V. Dangendorf

    Abstract: A compact liquid organic neutron spectrometer (CLONS) based on a single NE213 liquid scintillator (5 cm diam. x 5 cm) is described. The spectrometer is designed to measure neutron fluence spectra over the energy range 2-200 MeV and is suitable for use in neutron fields having any type of time structure. Neutron fluence spectra are obtained from measurements of two-parameter distributions (counts… ▽ More

    Submitted 23 March, 2007; originally announced March 2007.

    Comments: To be published in Radiation Protection Dosimetry

    Report number: NEUDOS10 Lect. (B4-2)

  22. arXiv:physics/0703186  [pdf

    physics.ins-det

    A position- and time-sensitive photon-counting detector with delay-line read-out

    Authors: O. Jagutzki, V. Dangendorf, R. Lauck, A. Czasch, J. Milnes

    Abstract: We have developed image intensifier tubes with delay-anode read-out for time- and position-sensitive photon counting. The timing precision is better than 1 ns with 1000x1000 pixels position resolution and up to one megacounts/s processing rate. Large format detectors of 40 and 75 mm active diameter with internal helical-wire delay-line anodes have been produced and specified. A different type of… ▽ More

    Submitted 19 March, 2007; originally announced March 2007.

    Comments: Proceedings of SPIE Conference "Optics and Optoelectronics", 16 - 19. Apr.2007

  23. Neutron imaging with a Micromegas detector

    Authors: F. Jeanneau, R. Junca, J. Pancin, M. Voytchev, S. Andriamonje, V. Dangendorf, I. Espagnon, H. Friedrich, A. Giganon, I. Giomataris, A. Menelle, A. Pluquet, L. R. Rodriguez

    Abstract: The micropattern gaseous detector Micromegas has been developed for several years in Saclay and presents good performance for neutron detection. A prototype for neutron imaging has been designed and new results obtained in thermal neutron beams are presented. Based on previous results demonstrating a good 1D spatial resolution, a tomographic image of a multiwire cable has been performed using a… ▽ More

    Submitted 21 July, 2006; originally announced July 2006.

    Comments: 6 pages, 10 figures, presented at IEEE 2004 conference in Roma, Italy

    Journal ref: IEEE-TNS, vol. 53, No 2, april 2006, p 595-600

  24. arXiv:physics/0606210  [pdf

    physics.med-ph physics.ins-det

    Advances in imaging THGEM-based detectors

    Authors: M. Cortesi, R. Chechik, A. Breskin, G. Guedes, V. Dangendorf, D. Vartzky, D. Bar

    Abstract: The thick GEM (THGEM) [1] is an "expanded" GEM, economically produced in the PCB industry by simple drilling and etching in G-10 or other insulating materials (fig. 1). Similar to GEM, its operation is based on electron gas avalanche multiplication in sub-mm holes, resulting in very high gain and fast signals. Due to its large hole size, the THGEM is particularly efficient in transporting the el… ▽ More

    Submitted 25 June, 2006; originally announced June 2006.

    Comments: 3 pages, 3 figures. Presented at the 10th Pisa Meeting on Advanced Detectors; ELBA-Italy; May 21-27 2006

    Journal ref: Nucl.Instrum.Meth.A572:175-176,2007

  25. arXiv:physics/0606162  [pdf

    physics.ins-det

    Thick GEM-like (THGEM) detectors and their possible applications

    Authors: R. Chechik, M. Cortesi, A. Breskin, D. Vartsky, D. Bar, V. Dangendorf

    Abstract: Thick GEM-like (THGEM) electrodes are robust, high gain gaseous electron multipliers, economically-manufactured by standard drilling and etching of thin printed circuit board or other materials. Their operation and structure are similar to that of standard GEMs but with 5 to 20-fold expanded dimensions. Due to the larger hole dimensions they provide up to 10^5 and 10^7 charge multiplication, in… ▽ More

    Submitted 18 June, 2006; originally announced June 2006.

    Comments: 3 pages, 6 figures, SNIC Symposium, Stanford, California, 3-6 April 2006

    Journal ref: ECONFC0604032:0025,2006

  26. arXiv:physics/0602188  [pdf

    physics.ins-det astro-ph nucl-ex nucl-th

    Amplification and Scintillation Properties of Oxygen-Rich Gas Mixtures for Optical-TPC Applications

    Authors: L. Weissman, M. Gai, A. Breskin, R. Chechik, V. Dangendorf, K. Tittelmeier, H. R. Weller

    Abstract: We studied electron amplification and light emission from avalanches in oxygen-containing gas mixtures. The mixtures investigated in this work included, among others, CO2 and N2O mixed with Triethylamine (TEA) or N2. Double-Step Parallel Gap (DSPG) multipliers and THick Gas Electron Multipliers (THGEM) were investigated. High light yields were measured from CO2+N2 and CO2+TEA, though with differ… ▽ More

    Submitted 27 May, 2006; v1 submitted 27 February, 2006; originally announced February 2006.

    Comments: Paper published in the new online only Journal of Instrumentation, JINST. Work supported by: USDOE grant Number DE-FG02-94ER40870, the Yale-Weizmann Collaboration, ACWIS, New-York, the Benoziyo Center for High-Energy Research at the Weizmann Institute, the Israel Science Foundation - project 151/01

    Report number: UConn-40870-0XXX

    Journal ref: JINST1:P05002,2006

  27. arXiv:physics/0410261  [pdf

    physics.ins-det

    Development and application of an optical TPC for charged particle track structure imaging in microdosimetry

    Authors: U. Titt, V. Dangendorf, B. Grosswendt, H. Schuhmacher

    Abstract: An imaging system for measuring the track structure of charged particles in a low-pressure gas is presented. We describe the experimental method and compare experimental results with first results of a simulation of the chamber response.

    Submitted 27 October, 2004; originally announced October 2004.

  28. arXiv:physics/0410260  [pdf

    physics.ins-det

    Imaging of microscopic features of charged-particle tracks in a low-pressure gas

    Authors: V. Dangendorf, H. Schuhmacher, U. Titt, K. Tittelmeier

    Abstract: An imaging system for measuring the spatial distribtion of charged particle tracks in a low-pressure gas is presented. The method is based on an optically read out time projection chamber. Results of experiments with fast heavy ions are shown.

    Submitted 27 October, 2004; originally announced October 2004.

  29. arXiv:physics/0410259  [pdf

    physics.ins-det

    Digital imaging of charged particle track structures with a low-pressure optical time projection chamber

    Authors: U. Titt, V. Dangendorf, H. Schuhmacher

    Abstract: We describe first results obtained with a track structure imaging system for measuring the ionisation topology of charged particles in a low-pressure gas. The detection method is based on a time projection chamber (TPC) filled with low-pressure triethylamine (TEA). Images of ionisation tracks of electrons, protons, and heavier ions are presented and analysed.

    Submitted 27 October, 2004; originally announced October 2004.

  30. arXiv:physics/0410258  [pdf

    physics.ins-det

    A time projection chamber with optical readout for charged particle track structure imaging

    Authors: U. Titt, A. Breskin, R. Chechik, V. Dangendorf, H. Schmidt-Boecking, H. Schuhmacher

    Abstract: We report about a nuclear track imaging system which is designed to study in detail the ionization topology of charged particle tracks in a low-pressure gas. The detection method is based on a time projection chamber (TPC) filled with low-pressure triethylamine (TEA). Ionization electrons produced by energetic charged particles are three-dimensionally imaged by recording light from electron aval… ▽ More

    Submitted 27 October, 2004; originally announced October 2004.

  31. arXiv:physics/0408076  [pdf

    physics.ins-det physics.comp-ph

    Time-resolved fast neutron imaging: simulation of detector performance

    Authors: D. Vartsky, I. Mor, M. B. Goldberg, I. Mardor, G. Feldman, D. Bar, A. Shor, V. Dangendorf, G. Laczko, A. Breskin, R. Chechik

    Abstract: We have analyzed and compared the performance of two novel fast-neutron imaging methods with time-of-flight spectroscopy capability. Using MCNP and GEANT code simulations of neutron and charged-particle transport in the detectors, key parameters such as detection efficiency, the amount of energy deposited in the converter and the spatial resolution of both detector variants have been evaluated.

    Submitted 17 August, 2004; originally announced August 2004.

  32. Detectors for Time-of-Flight Fast-Neutron Radiography: 1. Neutron Counting Gas Detector

    Authors: V. Dangendorf, A. Breskin, R. Chechik, M. Goldberg, G. Laczko, I. Mor, M. Reginatto, D. Vartsky

    Abstract: One of our two methods for fast-neutron imaging with spectrometric capability is presented here. It is a neutron-counting technique based on a hydrogenous neutron converter coupled to Gaseous Electron Multipliers (GEM). The principles of the detection techniques and the optimization of the converter, electron amplification and the readout are described. Evaluation of the properties are derived f… ▽ More

    Submitted 17 August, 2004; originally announced August 2004.