Time Projection Chamber (TPC) Detectors for Nuclear Astrophysics Studies With Gamma Beams
Authors:
M. Gai,
D. Schweitzer,
S. R. Stern,
A. H. Young,
R. Smith,
M. Cwiok,
J. S. Bihalowicz,
H. Czyrkowski,
R. Dabrowski,
W. Dominik,
A. Fijalkowska,
Z. Janas,
L. Janiak,
A. Korgul,
T. Matulewicz,
C. Mazzocchi,
M. Pfuetzner,
M. Zaremba,
D. Balabanski,
I. Gheorghe,
C. Matei,
O. Tesileanu,
N. V. Zamfir,
M. W. Ahmed,
S. S. Henshaw
, et al. (11 additional authors not shown)
Abstract:
Gamma-Beams at the HIgS facility in the USA and anticipated at the ELI-NP facility, now constructed in Romania, present unique new opportunities to advance research in nuclear astrophysics; not the least of which is resolving open questions in oxygen formation during stellar helium burning via a precise measurement of the 12C(a,g) reaction. Time projection chamber (TPC) detectors operating with lo…
▽ More
Gamma-Beams at the HIgS facility in the USA and anticipated at the ELI-NP facility, now constructed in Romania, present unique new opportunities to advance research in nuclear astrophysics; not the least of which is resolving open questions in oxygen formation during stellar helium burning via a precise measurement of the 12C(a,g) reaction. Time projection chamber (TPC) detectors operating with low pressure gas (as an active target) are ideally suited for such studies. We review the progress of the current research program and plans for the future at the HIγS facility with the optical readout TPC (O-TPC) and the development of an electronic readout TPC for the ELI-NP facility (ELITPC).
△ Less
Submitted 22 December, 2018;
originally announced December 2018.
-
A method for rapid determination of oil and water content in geological formations
Authors:
D. Vartsky,
M. B. Goldberg,
V. Dangendorf,
I. Israelashvili,
I. Mor,
D. Bar,
K. Tittelmeier,
M. Weierganz,
B. Bromberger,
A. Breskin
Abstract:
A novel method utilizing Fast Neutron Resonance Transmission Radiography is proposed for rapid, non-destructive and quantitative determination of the weight fractions of oil and water in cores taken from subterranean or underwater geological formations. Its ability to distinguish water from oil stems from the unambiguously-specific energy-dependence of the neutron cross-sections for the principal…
▽ More
A novel method utilizing Fast Neutron Resonance Transmission Radiography is proposed for rapid, non-destructive and quantitative determination of the weight fractions of oil and water in cores taken from subterranean or underwater geological formations. Its ability to distinguish water from oil stems from the unambiguously-specific energy-dependence of the neutron cross-sections for the principal elemental constituents. Furthermore, the fluid weight fractions permit determining core porosity and oil and water saturations. In this article we show results of experimental determination of oil and water weight fractions in 10 cm thick samples of Berea Sandstone and Indiana Limestone formations, followed by calculation of their porosity and fluid saturations. The technique may ultimately permit rapid, accurate and non-destructive evaluation of relevant petro-physical properties in thick intact cores. It is suitable for all types of formations including tight shales, clays and oil sands.
△ Less
Submitted 22 June, 2017;
originally announced June 2017.
-
Quantitative discrimination between oil and water in drilled bore cores via fast-neutron resonance transmission radiography
Authors:
D. Vartsky,
M. B. Goldberg,
V. Dangendorf,
I. Israelashvili,
I. Mor,
D. Bar,
K. Tittelmeier,
M. Weierganz,
A. Breskin
Abstract:
A novel method based on Fast Neutron Resonance Transmission Radiography is proposed for non-destructive, quantitative determination of the weight percentages of oil and water in cores taken from subterranean or underwater geological formations. The ability of the method to distinguish water from oil stems from the unambiguously-specific energy dependence of the neutron cross-sections for the princ…
▽ More
A novel method based on Fast Neutron Resonance Transmission Radiography is proposed for non-destructive, quantitative determination of the weight percentages of oil and water in cores taken from subterranean or underwater geological formations. The ability of the method to distinguish water from oil stems from the unambiguously-specific energy dependence of the neutron cross-sections for the principal elemental constituents. Monte-Carlo simulations and initial results of experimental investigations indicate that the technique may provide a rapid, accurate and non-destructive method for quantitative evaluation of core fluids in thick intact cores, including those of tight shales for which the use of conventional core analytical approaches appears to be questionable.
△ Less
Submitted 21 February, 2016;
originally announced February 2016.
-
Time-resolved fast-neutron radiography of air-water two-phase flows in a rectangular channel by an improved detection system
Authors:
Robert Zboray,
Volker Dangendorf,
Ilan Mor,
Benjamin Bromberger,
Kai Tittelmeier
Abstract:
In a previous work we have demonstrated the feasibility of high-frame-rate, fast-neutron radiography of generic air-water two-phase flows in a 1.5 cm thick, rectangular flow channel. The experiments have been carried out at the high-intensity, white-beam facility of the Physikalisch-Technische Bundesanstalt, Germany, using an multi-frame, time-resolved detector developed for fast neutron resonance…
▽ More
In a previous work we have demonstrated the feasibility of high-frame-rate, fast-neutron radiography of generic air-water two-phase flows in a 1.5 cm thick, rectangular flow channel. The experiments have been carried out at the high-intensity, white-beam facility of the Physikalisch-Technische Bundesanstalt, Germany, using an multi-frame, time-resolved detector developed for fast neutron resonance radiography. The results were however not fully optimal and therefore we have decided to modify the detector and optimize it for the given application, which is described in the present work. Furthermore, we managed to improve the image post-processing methodology and the noise suppression. Using the tailored detector and the improved post-processing significant increase in the image quality and an order of magnitude lower exposure times, down to 3.33 ms, have been achieved with minimized motion artifacts. Similar to the previous study, different two-phase flow regimes such as bubbly slug and churn flows have been examined. The enhanced imaging quality enables an improved prediction of two-phase flow parameters like the instantaneous volumetric gas fraction, bubble size and bubble velocities. Instantaneous velocity fields around the gas enclosures can also be more robustly predicted using optical flow methods as previously.
△ Less
Submitted 8 April, 2015;
originally announced April 2015.
-
High-frame rate, fast neutron imaging of two-phase flow in a thin rectangular channel
Authors:
R. Zboray,
I. Mor,
V. Dangendorf,
M. Stark,
K. Tittelmeier,
M. Cortesi,
R. Adams
Abstract:
We have demonstrated the feasibility of performing high-frame-rate, fast neutron radiography of air-water two-phase flows in a thin channel with rectangular cross section. The experiments have been carried out at the accelerator facility of the Physikalisch-Technische Bundesanstalt. A polychromatic, high-intensity fast neutron beam with average energy of 6 MeV was produced by 11.5 MeV deuterons hi…
▽ More
We have demonstrated the feasibility of performing high-frame-rate, fast neutron radiography of air-water two-phase flows in a thin channel with rectangular cross section. The experiments have been carried out at the accelerator facility of the Physikalisch-Technische Bundesanstalt. A polychromatic, high-intensity fast neutron beam with average energy of 6 MeV was produced by 11.5 MeV deuterons hitting a thick Be target. Image sequences down to 10 millisecond exposure times were obtained using a fast-neutron imaging detector developed in the context of fast-neutron resonance imaging. Different two-phase flow regimes such as bubbly slug and churn flows have been examined. Two phase flow parameters like the volumetric gas fraction, bubble size and bubble velocities have been measured. The first results are promising, improvements for future experiments are also discussed.
△ Less
Submitted 8 April, 2015;
originally announced April 2015.
-
Time-resolved neutron imaging at ANTARES cold neutron beamline
Authors:
A. S. Tremsin,
V. Dangendorf,
K. Tittelmeier,
B. Schillinger,
M. Schulz,
M. Lerche,
W. B. Feller
Abstract:
In non-destructive evaluation with X-rays light elements embedded in dense, heavy (or high-Z) matrices show little contrast and their structural details can hardly be revealed. Neutron radiography, on the other hand, provides a solution for those cases, in particular for hydrogenous materials, owing to the large neutron scattering cross section of hydrogen and uncorrelated dependency of neutron cr…
▽ More
In non-destructive evaluation with X-rays light elements embedded in dense, heavy (or high-Z) matrices show little contrast and their structural details can hardly be revealed. Neutron radiography, on the other hand, provides a solution for those cases, in particular for hydrogenous materials, owing to the large neutron scattering cross section of hydrogen and uncorrelated dependency of neutron cross section on the atomic number. The majority of neutron imaging experiments at the present time is conducted with static objects mainly due to the limited flux intensity of neutron beamline facilities and sometimes due to the limitations of the detectors. However, some applications require the studies of dynamic phenomena and can now be conducted at several high intensity beamlines such as the recently rebuilt ANTARES beam line at the FRM-II reactor. In this paper we demonstrate the capabilities of time resolved imaging for repetitive processes, where different phases of the process can be imaged simultaneously and integrated over multiple cycles. A fast MCP/Timepix neutron counting detector was used to image the water distribution within a model steam engine operating at 10 Hz frequency. Within <10 minutes integration the amount of water was measured as a function of cycle time with a sub-mm spatial resolution, thereby demonstrating the capabilities of time-resolved neutron radiography for the future applications. The neutron spectrum of the ANTARES beamline as well as transmission spectra of a Fe sample were also measured with the Time Of Flight (TOF) technique in combination with a high resolution beam chopper. The energy resolution of our setup was found to be ~0.8% at 5 meV and ~1.7% at 25 meV.
△ Less
Submitted 31 January, 2015;
originally announced February 2015.
-
Parameters Affecting Temporal Resolution of Time Resolved Integrative Optical Neutron Detector (TRION)
Authors:
I. Mor,
D. Vartsky,
V. Dangendorf,
D. Bar,
G. Feldman,
M. B. Goldberg,
K. Tittelmeier,
B. Bromberger,
M. Brandis,
M. Weierganz
Abstract:
The Time-Resolved Integrative Optical Neutron (TRION) detector was developed for Fast Neutron Resonance Radiography (FNRR), a fast-neutron transmission imaging method that exploits characteristic energy-variations of the total scattering cross-section in the En = 1-10 MeV range to detect specific elements within a radiographed object. As opposed to classical event-counting time of flight (ECTOF),…
▽ More
The Time-Resolved Integrative Optical Neutron (TRION) detector was developed for Fast Neutron Resonance Radiography (FNRR), a fast-neutron transmission imaging method that exploits characteristic energy-variations of the total scattering cross-section in the En = 1-10 MeV range to detect specific elements within a radiographed object. As opposed to classical event-counting time of flight (ECTOF), it integrates the detector signal during a well-defined neutron Time of Flight window corresponding to a pre-selected energy bin, e.g., the energy-interval spanning a cross-section resonance of an element such as C, O and N. The integrative characteristic of the detector permits loss-free operation at very intense, pulsed neutron fluxes, at a cost however, of recorded temporal resolution degradation.
This work presents a theoretical and experimental evaluation of detector related parameters which affect temporal resolution of the TRION system.
△ Less
Submitted 12 November, 2013;
originally announced November 2013.
-
Unambiguous Identification of the Second 2+ State in 12C and the Structure of the Hoyle State
Authors:
W. R. Zimmerman,
M. W. Ahmed,
B. Bromberger,
S. C. Stave,
A. Breskin,
V. Dangendorf,
Th. Delbar,
M. Gai,
S. S. Henshaw,
J. M. Mueller,
C. Sun,
K. Tittelmeier,
H. R. Weller,
Y. K. Wu
Abstract:
The second 2+ state of 12C, predicted over fifty years ago as an excitation of the Hoyle state, has been unambiguously identified using the 12C(g,a_0)8Be reaction. The alpha particles produced by the photodisintegration of 12C were detected using an Optical Time Projection Chamber (O-TPC). Data were collected at beam energies between 9.1 and 10.7 MeV using the intense nearly mono-energetic gamma-r…
▽ More
The second 2+ state of 12C, predicted over fifty years ago as an excitation of the Hoyle state, has been unambiguously identified using the 12C(g,a_0)8Be reaction. The alpha particles produced by the photodisintegration of 12C were detected using an Optical Time Projection Chamber (O-TPC). Data were collected at beam energies between 9.1 and 10.7 MeV using the intense nearly mono-energetic gamma-ray beams at the HIgS facility. The measured angular distributions determine the cross section and the E1-E2 relative phases as a function of energy leading to an unambiguous identification of the second 2+ state in 12C at 10.03(11) MeV, with a total width of 800(130) keV and a ground state gamma-decay width of 60(10) meV; B(E2: 2+ ---> gs) = 0.73(13) e2fm4 [or 0.45(8) W.u.]. The Hoyle state and its rotational 2+ state that are more extended than the ground state of 12C presents a challenge and constraints for models attempting to reveal the nature of three alpha particle states in 12C. Specifically it challenges the ab-initio Lattice Effective Field Theory (L-EFT) calculations that predict similar r.m.s. radii for the ground state and the Hoyle state.
△ Less
Submitted 18 March, 2013;
originally announced March 2013.
-
Time and position sensitive single photon detector for scintillator read-out
Authors:
Sven Schössler,
Benjamin Bromberger,
Michal Brandis,
Lothar Ph. H. Schmidt,
Kai Tittelmeier,
Achim Czasch,
Volker Dangendorf,
Ottmar Jagutzki
Abstract:
We have developed a photon counting detector system for combined neutron and gamma radiography which can determine position, time and intensity of a secondary photon flash created by a high-energy particle or photon within a scintillator screen. The system is based on a micro-channel plate photomultiplier concept utilizing image charge coupling to a position- and time-sensitive read-out anode plac…
▽ More
We have developed a photon counting detector system for combined neutron and gamma radiography which can determine position, time and intensity of a secondary photon flash created by a high-energy particle or photon within a scintillator screen. The system is based on a micro-channel plate photomultiplier concept utilizing image charge coupling to a position- and time-sensitive read-out anode placed outside the vacuum tube in air, aided by a standard photomultiplier and very fast pulse-height analyzing electronics. Due to the low dead time of all system components it can cope with the high throughput demands of a proposed combined fast neutron and dual discrete energy gamma radiography method (FNDDER). We show tests with different types of delay-line read-out anodes and present a novel pulse-height-to-time converter circuit with its potential to discriminate gamma energies for the projected FNDDER devices for an automated cargo container inspection system (ACCIS).
△ Less
Submitted 10 February, 2012; v1 submitted 12 January, 2012;
originally announced January 2012.
-
An Optical Readout TPC (O-TPC) for Studies in Nuclear Astrophysics With Gamma-Ray Beams at HIgS
Authors:
M. Gai,
M. W. Ahmed,
S. C. Stave,
W. R. Zimmerman,
A. Breskin,
B. Bromberger,
R. Chechik,
V. Dangendorf,
Th. Delbar,
R. H. France III,
S. S. Henshaw,
T. J. Kading,
P. P. Martel,
J. E. R. McDonald,
P. -N. Seo,
K. Tittelmeier,
H. R. Weller,
A. H. Young
Abstract:
We report on the construction, tests, calibrations and commissioning of an Optical Readout Time Projection Chamber (O-TPC) detector operating with a CO2(80%) + N2(20%) gas mixture at 100 and 150 Torr. It was designed to measure the cross sections of several key nuclear reactions involved in stellar evolution. In particular, a study of the rate of formation of oxygen and carbon during the process o…
▽ More
We report on the construction, tests, calibrations and commissioning of an Optical Readout Time Projection Chamber (O-TPC) detector operating with a CO2(80%) + N2(20%) gas mixture at 100 and 150 Torr. It was designed to measure the cross sections of several key nuclear reactions involved in stellar evolution. In particular, a study of the rate of formation of oxygen and carbon during the process of helium burning will be performed by exposing the chamber gas to intense nearly mono-energetic gamma-ray beams at the High Intensity Gamma Source (HIgS) facility. The O-TPC has a sensitive target-drift volume of 30x30x21 cm^3. Ionization electrons drift towards a double parallel grid avalanche multiplier, yielding charge multiplication and light emission. Avalanche induced photons from N2 emission are collected, intensified and recorded with a Charge Coupled Device (CCD) camera, providing two-dimensional track images. The event's time projection (third coordinate) and the deposited energy are recorded by photomultipliers and by the TPC charge-signal, respectively. A dedicated VME-based data acquisition system and associated data analysis tools were developed to record and analyze these data. The O-TPC has been tested and calibrated with 3.183 MeV alpha-particles emitted by a 148Gd source placed within its volume with a measured energy resolution of 3.0%. Tracks of alpha and 12C particles from the dissociation of 16O and of three alpha-particles from the dissociation of 12C have been measured during initial in-beam test experiments performed at the HIgS facility at Duke University. The full detection system and its performance are described and the results of the preliminary in-beam test experiments are reported.
△ Less
Submitted 10 January, 2011;
originally announced January 2011.
-
Development of an LED reference light source for calibration of radiographic imaging detectors
Authors:
M. Weierganz,
D. Bar,
B. Bromberger,
V. Dangendorf,
G. Feldman,
M. B. Goldberg,
M. Lindemann,
I. Mor,
K. Tittelmeier,
D. Vartsky
Abstract:
A stable reference light source based on an LED (Light Emission Diode) is presented for stabilizing the conversion gain of the opto-electronic system of a gamma- and fast-neutron radiographic and tomographic imaging device. A constant fraction of the LED light is transported to the image plane of the camera and provides a stable reference exposure. This is used to normalize the images during off…
▽ More
A stable reference light source based on an LED (Light Emission Diode) is presented for stabilizing the conversion gain of the opto-electronic system of a gamma- and fast-neutron radiographic and tomographic imaging device. A constant fraction of the LED light is transported to the image plane of the camera and provides a stable reference exposure. This is used to normalize the images during off-line image processing. We have investigated parameters influencing the stability of LEDs and developed procedures and criteria to prepare and select LEDs suitable for delivering stable light outputs for several 100 h of operation.
△ Less
Submitted 8 February, 2010;
originally announced February 2010.
-
High Spatial Resolution Fast-Neutron Imaging Detectors for Pulsed Fast-Neutron Transmission Spectroscopy
Authors:
I. Mor,
D. Vartsky,
D. Bar,
G. Feldman,
M. B. Goldberg,
D. Katz,
E. Sayag,
I. Shmueli,
Y. Cohen,
A. Tal,
Z. Vagish,
B. Bromberger,
V. Dangendorf,
D. Mugai,
K. Tittelmeier,
M. Weierganz
Abstract:
Two generations of a novel detector for high-resolution transmission imaging and spectrometry of fast-neutrons are presented. These devices are based on a hydrogenous fiber scintillator screen and single- or multiple-gated intensified camera systems (ICCD). This detector is designed for energy-selective neutron radiography with nanosecond-pulsed broad-energy (1 - 10 MeV) neutron beams. Utilizing…
▽ More
Two generations of a novel detector for high-resolution transmission imaging and spectrometry of fast-neutrons are presented. These devices are based on a hydrogenous fiber scintillator screen and single- or multiple-gated intensified camera systems (ICCD). This detector is designed for energy-selective neutron radiography with nanosecond-pulsed broad-energy (1 - 10 MeV) neutron beams. Utilizing the Time-of-Flight (TOF) method, such a detector is capable of simultaneously capturing several images, each at a different neutron energy (TOF). In addition, a gamma-ray image can also be simultaneously registered, allowing combined neutron/gamma inspection of objects. This permits combining the sensitivity of the fast-neutron resonance method to low-Z elements with that of gamma radiography to high-Z materials.
△ Less
Submitted 27 May, 2009;
originally announced May 2009.
-
Amplification and Scintillation Properties of Oxygen-Rich Gas Mixtures for Optical-TPC Applications
Authors:
L. Weissman,
M. Gai,
A. Breskin,
R. Chechik,
V. Dangendorf,
K. Tittelmeier,
H. R. Weller
Abstract:
We studied electron amplification and light emission from avalanches in oxygen-containing gas mixtures. The mixtures investigated in this work included, among others, CO2 and N2O mixed with Triethylamine (TEA) or N2. Double-Step Parallel Gap (DSPG) multipliers and THick Gas Electron Multipliers (THGEM) were investigated. High light yields were measured from CO2+N2 and CO2+TEA, though with differ…
▽ More
We studied electron amplification and light emission from avalanches in oxygen-containing gas mixtures. The mixtures investigated in this work included, among others, CO2 and N2O mixed with Triethylamine (TEA) or N2. Double-Step Parallel Gap (DSPG) multipliers and THick Gas Electron Multipliers (THGEM) were investigated. High light yields were measured from CO2+N2 and CO2+TEA, though with different emission spectra. We observed the characteristic wave-length emission of N2 and of TEA and used a polymer wave-length shifter to convert TEA UV-light into the visible spectrum. The results of these measurements indicate the applicability of optical recording of ionizing tracks in a TPC target-detector designed to study the cross section of the 16O(g,a)12C reaction, a central problem in nuclear astrophysics.
△ Less
Submitted 27 May, 2006; v1 submitted 27 February, 2006;
originally announced February 2006.
-
Imaging of microscopic features of charged-particle tracks in a low-pressure gas
Authors:
V. Dangendorf,
H. Schuhmacher,
U. Titt,
K. Tittelmeier
Abstract:
An imaging system for measuring the spatial distribtion of charged particle tracks in a low-pressure gas is presented. The method is based on an optically read out time projection chamber. Results of experiments with fast heavy ions are shown.
An imaging system for measuring the spatial distribtion of charged particle tracks in a low-pressure gas is presented. The method is based on an optically read out time projection chamber. Results of experiments with fast heavy ions are shown.
△ Less
Submitted 27 October, 2004;
originally announced October 2004.