-
Proceedings to the 25th International Workshop "What Comes Beyond the Standard Models", July 4 -- July 10, 2022, Bled, Slovenia
Authors:
R. Bernabei,
P. Belli,
A. Bussolotti,
V. Caracciolo,
R. Cerulli,
N. Ferrari,
A. Leoncini,
V. Merlo,
F. Montecchia,
F. Cappella,
A. dAngelo,
A. Incicchitti,
A. Mattei,
C. J. Dai,
X. H. Ma,
X. D. Sheng,
Z. P. Ye,
V. Beylin,
L. Bonora,
S. J. Brodsky,
Paul H. Frampton,
A. Ghoshal,
G. Lambiase,
S. Pal,
A. Paul
, et al. (29 additional authors not shown)
Abstract:
Proceedings for our meeting ``What comes beyond the Standard Models'', which covered a broad series of subjects.
Proceedings for our meeting ``What comes beyond the Standard Models'', which covered a broad series of subjects.
△ Less
Submitted 29 March, 2023;
originally announced March 2023.
-
Transmission of droplet-conveyed infectious agents such as SARS-CoV-2 by speech and vocal exercises during speech therapy: preliminary experiment concerning airflow velocity
Authors:
Antoine Giovanni,
Thomas Radulesco,
Gilles Bouchet,
Alexia Mattei,
Joana Révis,
Estelle Bogdanski,
Justin Michel
Abstract:
Purpose Infectious agents, such as SARS-CoV-2, can be carried by droplets expelled during breathing. The spatial dissemination of droplets varies according to their initial velocity. After a short literature review, our goal was to determine the velocity of the exhaled air during vocal exercises. Methods A propylene glycol cloud produced by 2 e-cigarettes' users allowed visualization of the exhale…
▽ More
Purpose Infectious agents, such as SARS-CoV-2, can be carried by droplets expelled during breathing. The spatial dissemination of droplets varies according to their initial velocity. After a short literature review, our goal was to determine the velocity of the exhaled air during vocal exercises. Methods A propylene glycol cloud produced by 2 e-cigarettes' users allowed visualization of the exhaled air emitted during vocal exercises. Airflow velocities were measured during the first 200 ms of a long exhalation, a sustained vowel /a/ and varied vocal exercises. For the long exhalation and the sustained vowel /a/, the decrease of airflow velocity was measured until 3 s. Results were compared with a Computational Fluid Dynamics (CFD) study using boundary conditions consistent with our experimental study. Results Regarding the production of vowels, higher velocities were found in loud and whispered voices than in normal voice. Voiced consonants like /3/ or /v/ generated higher velocities than vowels. Some voiceless consonants, e.g., /t/ generated high velocities, but long exhalation had the highest velocities. Semi-occluded vocal tract exercises generated faster airflow velocities than loud speech, with a decreased velocity during voicing. The initial velocity quickly decreased as was shown during a long exhalation or a sustained vowel /a/. Velocities were consistent with the CFD data. Conclusion Initial velocity of the exhaled air is a key factor influencing droplets trajectory. Our study revealed that vocal exercises produce a slower airflow than long exhalation. Speech therapy should, therefore, not be associated with an increased risk of contamination when implementing standard recommendations.
△ Less
Submitted 6 January, 2021;
originally announced January 2021.
-
QUBIC VII: The feedhorn-switch system of the technological demonstrator
Authors:
F. Cavaliere,
A. Mennella,
M. Zannoni,
P. Battaglia,
E. S. Battistelli,
D. Burke,
G. D'Alessandro,
P. de Bernardis,
M. De Petris,
C. Franceschet,
L. Grandsire,
J. -Ch. Hamilton,
B. Maffei,
E. Manzan,
S. Marnieros,
S. Masi,
C. O'Sullivan,
A. Passerini,
F. Pezzotta,
M. Piat,
A. Tartari,
S. A. Torchinsky,
D. Viganò,
F. Voisin,
P. Ade
, et al. (106 additional authors not shown)
Abstract:
We present the design, manufacturing and performance of the horn-switch system developed for the technological demonstrator of QUBIC (the $Q$\&$U$ Bolometric Interferometer for Cosmology). This system is constituted of 64 back-to-back dual-band (150\,GHz and 220\,GHz) corrugated feed-horns interspersed with mechanical switches used to select desired baselines during the instrument self-calibration…
▽ More
We present the design, manufacturing and performance of the horn-switch system developed for the technological demonstrator of QUBIC (the $Q$\&$U$ Bolometric Interferometer for Cosmology). This system is constituted of 64 back-to-back dual-band (150\,GHz and 220\,GHz) corrugated feed-horns interspersed with mechanical switches used to select desired baselines during the instrument self-calibration. We manufactured the horns in aluminum platelets milled by photo-chemical etching and mechanically tightened with screws. The switches are based on steel blades that open and close the wave-guide between the back-to-back horns and are operated by miniaturized electromagnets. We also show the current development status of the feedhorn-switch system for the QUBIC full instrument, based on an array of 400 horn-switch assemblies.
△ Less
Submitted 1 April, 2022; v1 submitted 28 August, 2020;
originally announced August 2020.
-
QUBIC V: Cryogenic system design and performance
Authors:
S. Masi,
E. S. Battistelli,
P. de Bernardis,
C. Chapron,
F. Columbro,
G. D'Alessandro,
M. De Petris,
L. Grandsire,
J. -Ch. Hamilton,
S. Marnieros,
L. Mele,
A. May,
A. Mennella,
C. O'Sullivan,
A. Paiella,
F. Piacentini,
M. Piat,
L. Piccirillo,
G. Presta,
A. Schillaci,
A. Tartari,
J. -P. Thermeau,
S. A. Torchinsky,
F. Voisin,
M. Zannoni
, et al. (104 additional authors not shown)
Abstract:
Current experiments aimed at measuring the polarization of the Cosmic Microwave Background (CMB) use cryogenic detector arrays and cold optical systems to boost the mapping speed of the sky survey. For these reasons, large volume cryogenic systems, with large optical windows, working continuously for years, are needed. Here we report on the cryogenic system of the QUBIC (Q and U Bolometric Interfe…
▽ More
Current experiments aimed at measuring the polarization of the Cosmic Microwave Background (CMB) use cryogenic detector arrays and cold optical systems to boost the mapping speed of the sky survey. For these reasons, large volume cryogenic systems, with large optical windows, working continuously for years, are needed. Here we report on the cryogenic system of the QUBIC (Q and U Bolometric Interferometer for Cosmology) experiment: we describe its design, fabrication, experimental optimization and validation in the Technological Demonstrator configuration. The QUBIC cryogenic system is based on a large volume cryostat, using two pulse-tube refrigerators to cool at ~3K a large (~1 m^3) volume, heavy (~165kg) instrument, including the cryogenic polarization modulator, the corrugated feedhorns array, and the lower temperature stages; a 4He evaporator cooling at ~1K the interferometer beam combiner; a 3He evaporator cooling at ~0.3K the focal-plane detector arrays. The cryogenic system has been tested and validated for more than 6 months of continuous operation. The detector arrays have reached a stable operating temperature of 0.33K, while the polarization modulator has been operated from a ~10K base temperature. The system has been tilted to cover the boresight elevation range 20 deg -90 deg without significant temperature variations. The instrument is now ready for deployment to the high Argentinean Andes.
△ Less
Submitted 25 August, 2021; v1 submitted 24 August, 2020;
originally announced August 2020.
-
Thermal architecture for the QUBIC cryogenic receiver
Authors:
A. J. May,
C. Chapron,
G. Coppi,
G. D'Alessandro,
P. de Bernardis,
S. Masi,
S. Melhuish,
M. Piat,
L. Piccirillo,
A. Schillaci,
J. -P. Thermeau,
P. Ade,
G. Amico,
D. Auguste,
J. Aumont,
S. Banfi,
G. Barbara,
P. Battaglia,
E. Battistelli,
A. Bau,
B. Belier,
D. Bennett,
L. Berge,
J. -Ph. Bernard,
M. Bersanelli
, et al. (105 additional authors not shown)
Abstract:
QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming instrument to measure the B-mode polarization anisotropy of the Cosmic Microwave Background. The detection of the B-mode signal will be extremely challenging; QUBIC has been designed to address this with a novel approach, namely bolometric interferometry. The receiver cryostat is exceptionally large and cools complex opt…
▽ More
QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming instrument to measure the B-mode polarization anisotropy of the Cosmic Microwave Background. The detection of the B-mode signal will be extremely challenging; QUBIC has been designed to address this with a novel approach, namely bolometric interferometry. The receiver cryostat is exceptionally large and cools complex optical and detector stages to 40 K, 4 K, 1 K and 350 mK using two pulse tube coolers, a novel 4He sorption cooler and a double-stage 3He/4He sorption cooler. We discuss the thermal and mechanical design of the cryostat, modelling and thermal analysis, and laboratory cryogenic testing.
△ Less
Submitted 6 November, 2018;
originally announced November 2018.
-
First model independent results from DAMA/LIBRA-phase2
Authors:
R. Bernabei,
P. Belli,
A. Bussolotti,
F. Cappella,
V. Caracciolo,
R. Cerulli,
C. J. Dai,
A. d'Angelo,
A. Di Marco,
H. L. He,
A. Incicchitti,
X. H. Ma,
A. Mattei,
V. Merlo,
F. Montecchia,
X. D. Sheng,
Z. P. Ye
Abstract:
The first model independent results obtained by the DAMA/LIBRA-phase2 experiment are presented. The data have been collected over 6 annual cycles corresponding to a total exposure of 1.13 ton $\times$ yr, deep underground at the Gran Sasso National Laboratory (LNGS) of the I.N.F.N. The DAMA/LIBRA-phase2 apparatus, $\simeq$ 250 kg highly radio-pure NaI(Tl), profits from a second generation high qua…
▽ More
The first model independent results obtained by the DAMA/LIBRA-phase2 experiment are presented. The data have been collected over 6 annual cycles corresponding to a total exposure of 1.13 ton $\times$ yr, deep underground at the Gran Sasso National Laboratory (LNGS) of the I.N.F.N. The DAMA/LIBRA-phase2 apparatus, $\simeq$ 250 kg highly radio-pure NaI(Tl), profits from a second generation high quantum efficiency photomultipliers and of new electronics with respect to DAMA/LIBRA-phase1. The improved experimental configuration has also allowed to lower the software energy threshold. New data analysis strategies are presented. The DAMA/LIBRA-phase2 data confirm the evidence of a signal that meets all the requirements of the model independent Dark Matter (DM) annual modulation signature, at 9.5 $σ$ C.L. in the energy region (1-6) keV. In the energy region between 2 and 6 keV, where data are also available from DAMA/NaI and DAMA/LIBRA-phase1 (exposure $1.33$ ton $\times$ yr, collected over 14 annual cycles), the achieved C.L. for the full exposure (2.46 ton $\times$ yr) is 12.9 $σ$; the modulation amplitude of the single-hit scintillation events is: $(0.0103 \pm 0.0008)$ cpd/kg/keV, the measured phase is $(145 \pm 5)$ days and the measured period is $(0.999 \pm 0.001)$ yr, all these values are well in agreement with those expected for DM particles. No systematics or side reaction able to mimic the exploited DM signature (i.e. to account for the whole measured modulation amplitude and to simultaneously satisfy all the requirements of the signature), has been found or suggested by anyone throughout some decades thus far.
△ Less
Submitted 11 January, 2019; v1 submitted 26 May, 2018;
originally announced May 2018.