Comparative studies of plastic scintillator strips with high technical attenuation length for the total-body J-PET scanner
Authors:
L. Kaplon,
J. Baran,
N. Chug,
A. Coussat,
C. Curceanu,
E. Czerwinski,
M. Dadgar,
K. Dulski,
J. Gajewski,
A. Gajos,
B. Hiesmayr,
E. Kavya Valsan,
K. Klimaszewski,
G. Korcyl,
T. Kozik,
W. Krzemien,
D. Kumar,
G. Moskal,
S. Niedzwiecki,
D. Panek,
S. Parzych,
E. Perez del Rio,
L. Raczynski,
A. Rucinski,
S. Sharma
, et al. (9 additional authors not shown)
Abstract:
Plastic scintillator strips are considered as one of the promising solutions for the cost-effective construction of total-body positron emission tomography, (PET) system. The purpose of the performed measurements is to compare the transparency of long plastic scintillators with dimensions 6 mm x 24 mm x 1000 mm and with all surfaces polished. Six different types of commercial, general purpose, blu…
▽ More
Plastic scintillator strips are considered as one of the promising solutions for the cost-effective construction of total-body positron emission tomography, (PET) system. The purpose of the performed measurements is to compare the transparency of long plastic scintillators with dimensions 6 mm x 24 mm x 1000 mm and with all surfaces polished. Six different types of commercial, general purpose, blue-emitting plastic scintillators with low attenuation of visible light were tested, namely: polyvinyl toluene-based BC-408, EJ-200, RP-408, and polystyrene-based Epic, SP32 and UPS-923A. For determination of the best type of plastic scintillator for totalbody Jagiellonian positron emission tomograph (TB-J-PET) construction, emission and transmission spectra, and technical attenuation length (TAL) of blue light-emitting by the scintillators were measured and compared. The TAL values were determined with the use of UV lamp as excitation source, and photodiode as light detector. Emission spectra of investigated scintillators have maxima in the range from 420 nm to 429 nm. The BC-408 and EJ-200 have the highest transmittance values of about 90% at the maximum emission wavelength measured through a 6 mm thick scintillator strip and the highest technical attenuation length reaching about 2000 mm, allowing assembly of long detection modules for time-of-flight (TOF) J-PET scanners. Influence of the 6 mm x 6 mm, 12 mm x 6 mm, 24 mm x 6 mm cross-sections of the 1000 mm long EJ-200 plastic scintillator on the TAL and signal intensity was measured. The highest TAL value was determined for samples with 24 mm x 6 mm cross-section.
△ Less
Submitted 28 July, 2024;
originally announced July 2024.
-
Detecting Iron Oxidation States in Liquids with the VOXES Bragg Spectrometer
Authors:
Simone Manti,
Marco Miliucci,
Alessandro Scordo,
Roberto Bedogni,
Alberto Clozza,
Mihail Iliescu,
Gabriel Moskal,
Kristian Piscicchia,
Alessio Porcelli,
Diana Sirghi,
Florin Sirghi,
Catalina Curceanu
Abstract:
Determining the oxidation states of metals assumes great importance in various applications because a variation in the oxidation number can drastically influence the material properties. As an example, this becomes evident in edible liquids like wine and oil, where a change in the oxidation states of the contained metals can significantly modify both the overall quality and taste. To this end, her…
▽ More
Determining the oxidation states of metals assumes great importance in various applications because a variation in the oxidation number can drastically influence the material properties. As an example, this becomes evident in edible liquids like wine and oil, where a change in the oxidation states of the contained metals can significantly modify both the overall quality and taste. To this end, here we present the MITIQO project, which aims to identify oxidation states of metals in edible liquids utilizing X-ray emission with Bragg spectroscopy. This is achieved using the VOXES crystal spectrometer, developed at INFN National Laboratories of Frascati (LNF), employing mosaic crystal (HAPG) in the Von Hamos configuration. This combination allow us to work with effective source sizes of up to a few millimeters and improves the typical low efficiency of Bragg spectroscopy, a crucial aspect when studying liquids with low metal concentration. Here we showcase the concept behind MITIQO, for a liquid solution containing oxidized iron. We performed several high-resolution emission spectra measurements, for the liquid and for different powdered samples containing oxidized and pure iron. By looking at the spectral features of the iron's K$β$ emission lineshape, we were able to obtain, for a liquid, a result consistent with the oxidized iron powders and successfully quantifying the effect of oxidation.
△ Less
Submitted 9 October, 2023;
originally announced October 2023.
-
TOF MLEM Adaptation for the Total-Body J-PET with a Realistic Analytical System Response Matrix
Authors:
R. Y. Shopa,
J. Baran,
K. Klimaszewski,
W. Krzemień,
L. Raczyński,
W. Wiślicki,
K. Brzeziński,
N. Chug,
A. Coussat,
C. Curceanu,
E. Czerwiński,
M. Dadgar,
K. Dulski,
J. Gajewski,
A. Gajos,
B. C. Hiesmayr,
E. Kavya Valsan,
G. Korcyl,
T. Kozik,
D. Kumar,
Ł. Kapłon,
G. Moskal,
S. Niedźwiecki,
D. Panek,
S. Parzych
, et al. (10 additional authors not shown)
Abstract:
We report a study of the original image reconstruction algorithm based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM), developed for the total-body (TB) Jagiellonian PET (J-PET) scanners. The method is applicable to generic cylindrical or modular multi-layer layouts and is extendable to multi-photon imaging. The system response matrix (SRM) is represented as a set of…
▽ More
We report a study of the original image reconstruction algorithm based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM), developed for the total-body (TB) Jagiellonian PET (J-PET) scanners. The method is applicable to generic cylindrical or modular multi-layer layouts and is extendable to multi-photon imaging. The system response matrix (SRM) is represented as a set of analytical functions, uniquely defined for each pair of plastic scintillator strips used for the detection. A realistic resolution model (RM) in detector space is derived from fitting the Monte Carlo simulated emissions and detections of annihilation photons on oblique transverse planes. Additional kernels embedded in SRM account for TOF, parallax effect and axial smearing. The algorithm was tested on datasets, simulated in GATE for the NEMA IEC and static XCAT phantoms inside a 24-module 2-layer TB J-PET. Compared to the reference TOF MLEM with none or a shift-invariant RM, an improvement was observed, as evaluated by the analysis of image quality, difference images and ground truth metrics. We also reconstructed the data with additive contributions, pre-filtered geometrically and with non-TOF scatter correction applied. Despite some deterioration, the obtained results still capitalise on the realistic RM with better edge preservation and superior ground truth metrics. The envisioned prospects of the TOF MLEM with analytical SRM include its application in multi-photon imaging and further upgrade to account for the non-collinearity, positron range and other factors.
△ Less
Submitted 4 May, 2023; v1 submitted 6 February, 2023;
originally announced February 2023.