The helion charge radius from laser spectroscopy of muonic helium-3 ions
Authors:
The CREMA Collaboration,
Karsten Schuhmann,
Luis M. P. Fernandes,
François Nez,
Marwan Abdou Ahmed,
Fernando D. Amaro,
Pedro Amaro,
François Biraben,
Tzu-Ling Chen,
Daniel S. Covita,
Andreas J. Dax,
Marc Diepold,
Beatrice Franke,
Sandrine Galtier,
Andrea L. Gouvea,
Johannes Götzfried,
Thomas Graf,
Theodor W. Hänsch,
Malte Hildebrandt,
Paul Indelicato,
Lucile Julien,
Klaus Kirch,
Andreas Knecht,
Franz Kottmann,
Julian J. Krauth
, et al. (15 additional authors not shown)
Abstract:
Hydrogen-like light muonic ions, in which one negative muon replaces all the electrons, are extremely sensitive probes of nuclear structure, because the large muon mass increases tremendously the wave function overlap with the nucleus. Using pulsed laser spectroscopy we have measured three 2S-2P transitions in the muonic helium-3 ion ($μ^3$He$^+$), an ion formed by a negative muon and bare helium-…
▽ More
Hydrogen-like light muonic ions, in which one negative muon replaces all the electrons, are extremely sensitive probes of nuclear structure, because the large muon mass increases tremendously the wave function overlap with the nucleus. Using pulsed laser spectroscopy we have measured three 2S-2P transitions in the muonic helium-3 ion ($μ^3$He$^+$), an ion formed by a negative muon and bare helium-3 nucleus. This allowed us to extract the Lamb shift $E(2P_{1/2}-2S_{1/2})= 1258.598(48)^{\rm exp}(3)^{\rm theo}$ meV, the 2P fine structure splitting $E_{\rm FS}^{\rm exp} = 144.958(114)$ meV, and the 2S-hyperfine splitting (HFS) $E_{\rm HFS}^{\rm exp} = -166.495(104)^{\rm exp}(3)^{\rm theo}$ meV in $μ^3$He$^+$. Comparing these measurements to theory we determine the rms charge radius of the helion ($^3$He nucleus) to be $r_h$ = 1.97007(94) fm. This radius represents a benchmark for few nucleon theories and opens the way for precision tests in $^3$He atoms and $^3$He-ions. This radius is in good agreement with the value from elastic electron scattering, but a factor 15 more accurate. Combining our Lamb shift measurement with our earlier one in $μ^4$He$^+$ we obtain $r_h^2-r_α^2 = 1.0636(6)^{\rm exp}(30)^{\rm theo}$ fm$^2$ to be compared to results from the isotope shift measurements in regular He atoms, which are however affected by long-standing tensions. By comparing $E_{\rm HFS}^{\rm exp}$ with theory we also obtain the two-photon-exchange contribution (including higher orders) which is another important benchmark for ab-initio few-nucleon theories aiming at understanding the magnetic and current structure of light nuclei.
△ Less
Submitted 25 June, 2023; v1 submitted 19 May, 2023;
originally announced May 2023.
-
The proton radius puzzle
Authors:
J. J. Krauth,
K. Schuhmann,
M. Abdou Ahmed,
F. D. Amaro,
P. Amaro,
F. Biraben,
J. M. R. Cardoso,
M. L. Carvalho,
D. S. Covita,
A. Dax,
S. Dhawan,
M. Diepold,
L. M. P. Fernandes,
B. Franke,
S. Galtier,
A. Giesen,
A. L. Gouvea,
J. Götzfried,
T. Graf,
M. Guerra,
J. Haack,
T. W. Hänsch,
M. Hildebrandt,
P. Indelicato,
L. Julien
, et al. (27 additional authors not shown)
Abstract:
High-precision measurements of the proton radius from laser spectroscopy of muonic hydrogen demonstrated up to six standard deviations smaller values than obtained from electron-proton scattering and hydrogen spectroscopy. The status of this discrepancy, which is known as the proton radius puzzle will be discussed in this paper, complemented with the new insights obtained from spectroscopy of muon…
▽ More
High-precision measurements of the proton radius from laser spectroscopy of muonic hydrogen demonstrated up to six standard deviations smaller values than obtained from electron-proton scattering and hydrogen spectroscopy. The status of this discrepancy, which is known as the proton radius puzzle will be discussed in this paper, complemented with the new insights obtained from spectroscopy of muonic deuterium.
△ Less
Submitted 19 August, 2017; v1 submitted 2 June, 2017;
originally announced June 2017.
-
Laser Spectroscopy of Muonic Atoms and Ions
Authors:
Randolf Pohl,
François Nez,
Luis M. P. Fernandes,
Marwan Abdou Ahmed,
Fernando D. Amaro,
Pedro Amaro,
François Biraben,
João M. R. Cardoso,
Daniel S. Covita,
Andreas Dax,
Satish Dhawan,
Marc Diepold,
Beatrice Franke,
Sandrine Galtier,
Adolf Giesen,
Andrea L. Gouvea,
Johannes Götzfried,
Thomas Graf,
Theodor W. Hänsch,
Malte Hildebrandt,
Paul Indelicato,
Lucile Julien,
Klaus Kirch,
Andreas Knecht,
Paul Knowles
, et al. (22 additional authors not shown)
Abstract:
Laser spectroscopy of the Lamb shift (2S-2P energy difference) in light muonic atoms or ions, in which one negative muon $μ^-$ is bound to a nucleus, has been performed. The measurements yield significantly improved values of the root-mean-square charge radii of the nuclei, owing to the large muon mass, which results in a vastly increased muon wave function overlap with the nucleus. The values of…
▽ More
Laser spectroscopy of the Lamb shift (2S-2P energy difference) in light muonic atoms or ions, in which one negative muon $μ^-$ is bound to a nucleus, has been performed. The measurements yield significantly improved values of the root-mean-square charge radii of the nuclei, owing to the large muon mass, which results in a vastly increased muon wave function overlap with the nucleus. The values of the proton and deuteron radii are 10 and 3 times more accurate than the respective CODATA values, but 7 standard deviations smaller. Data on muonic helium-3 and -4 ions is being analyzed and will give new insights. In future, the (magnetic) Zemach radii of the proton and the helium-3 nuclei will be determined from laser spectroscopy of the 1S hyperfine splittings, and the Lamb shifts of muonic Li, Be and B can be used to improve the respective charge radii.
△ Less
Submitted 12 September, 2016;
originally announced September 2016.
-
Experiments towards resolving the proton charge radius puzzle
Authors:
A. Antognini,
K. Schuhmann,
F. D. Amaro,
P. Amaro,
M. Abdou-Ahmed,
F. Biraben,
T. -L. Chen,
D. S. Covita,
A. J. Dax,
M. Diepold,
L. M. P. Fernandes,
B. Franke,
S. Galtier,
A. L. Gouvea,
J. Götzfried,
T. Graf,
T. W. Hänsch,
M. Hildebrandt,
P. Indelicato,
L. Julien,
K. Kirch,
A. Knecht,
F. Kottmann,
J. J. Krauth,
Y. -W. Liu
, et al. (12 additional authors not shown)
Abstract:
We review the status of the proton charge radius puzzle. Emphasis is given to the various experiments initiated to resolve the conflict between the muonic hydrogen results and the results from scattering and regular hydrogen spectroscopy.
We review the status of the proton charge radius puzzle. Emphasis is given to the various experiments initiated to resolve the conflict between the muonic hydrogen results and the results from scattering and regular hydrogen spectroscopy.
△ Less
Submitted 17 October, 2015; v1 submitted 10 September, 2015;
originally announced September 2015.
-
Improved X-ray detection and particle identification with avalanche photodiodes
Authors:
Marc Diepold,
Luis M. P. Fernandes,
Jorge Machado,
Pedro Amaro,
Marwan Abdou-Ahmed,
Fernando D. Amaro,
Aldo Antognini,
François Biraben,
Tzu-Ling Chen,
Daniel S. Covita,
Andreas J. Dax,
Beatrice Franke,
Sandrine Galtier,
Andrea L. Gouvea,
Johannes Götzfried,
Thomas Graf,
Theodor W. Hänsch,
Malte Hildebrandt,
Paul Indelicato,
Lucile Julien,
Klaus Kirch,
Andreas Knecht,
Franz Kottmann,
Julian J. Krauth,
Yi-Wei Liu
, et al. (14 additional authors not shown)
Abstract:
Avalanche photodiodes are commonly used as detectors for low energy x-rays. In this work we report on a fitting technique used to account for different detector responses resulting from photo absorption in the various APD layers. The use of this technique results in an improvement of the energy resolution at 8.2 keV by up to a factor of 2, and corrects the timing information by up to 25 ns to acco…
▽ More
Avalanche photodiodes are commonly used as detectors for low energy x-rays. In this work we report on a fitting technique used to account for different detector responses resulting from photo absorption in the various APD layers. The use of this technique results in an improvement of the energy resolution at 8.2 keV by up to a factor of 2, and corrects the timing information by up to 25 ns to account for space dependent electron drift time. In addition, this waveform analysis is used for particle identification, e.g. to distinguish between x-rays and MeV electrons in our experiment.
△ Less
Submitted 26 May, 2015;
originally announced May 2015.
-
Measurement of the Formation Rate of Muonic Hydrogen Molecules
Authors:
MuCap Collaboration,
V. A. Andreev,
T. I. Banks,
R. M. Carey,
T. A. Case,
S. M. Clayton,
K. M. Crowe,
J. Deutsch,
J. Egger,
S. J. Freedman,
V. A. Ganzha,
T. Gorringe,
F. E. Gray,
D. W. Hertzog,
M. Hildebrandt,
P. Kammel,
B. Kiburg,
S. Knaack,
P. A. Kravtsov,
A. G. Krivshich,
B. Lauss,
K. R. Lynch,
E. M. Maev,
O. E. Maev,
F. Mulhauser
, et al. (11 additional authors not shown)
Abstract:
Background: The rate λ_ppμ characterizes the formation of ppμ molecules in collisions of muonic pμ atoms with hydrogen. In measurements of the basic weak muon capture reaction on the proton to determine the pseudoscalar coupling g_P, capture occurs from both atomic and molecular states. Thus knowledge of λ_ppμ is required for a correct interpretation of these experiments.
Purpose: Recently the M…
▽ More
Background: The rate λ_ppμ characterizes the formation of ppμ molecules in collisions of muonic pμ atoms with hydrogen. In measurements of the basic weak muon capture reaction on the proton to determine the pseudoscalar coupling g_P, capture occurs from both atomic and molecular states. Thus knowledge of λ_ppμ is required for a correct interpretation of these experiments.
Purpose: Recently the MuCap experiment has measured the capture rate Λ_S from the singlet pμ atom, employing a low density active target to suppress ppμ formation (PRL 110, 12504 (2013)). Nevertheless, given the unprecedented precision of this experiment, the existing experimental knowledge in λ_ppμ had to be improved.
Method: The MuCap experiment derived the weak capture rate from the muon disappearance rate in ultra-pure hydrogen. By doping the hydrogen with 20 ppm of argon, a competing process to ppμ formation was introduced, which allowed the extraction of λ_ppμ from the observed time distribution of decay electrons.
Results: The ppμ formation rate was measured as λ_ppμ= (2.01 +- 0.06(stat) +- 0.03(sys)) 10^6 s^-1. This result updates the λ_ppμ value used in the above mentioned MuCap publication.
Conclusions: The 2.5x higher precision compared to earlier experiments and the fact that the measurement was performed at nearly identical conditions to the main data taking, reduces the uncertainty induced by λ_ppμ to a minor contribution to the overall uncertainty of Λ_S and g_P, as determined in MuCap. Our final value for λ_ppμ shifts Λ_S and g_P by less than one tenth of their respective uncertainties compared to our results published earlier.
△ Less
Submitted 3 February, 2015;
originally announced February 2015.
-
Lifetime and population of the 2S state in muonic protium and deuterium
Authors:
Marc Diepold,
Fernando D. Amaro,
Aldo Antognini,
François Biraben,
João M. R. Cardoso,
Daniel S. Covita,
Andreas Dax,
Satish Dhawan,
Luis M. P. Fernandes,
Adolf Giesen,
Andrea L. Gouvea,
Thomas Graf,
Theodor W. Hänsch,
Paul Indelicato,
Lucile Julien,
Cheng-Yang Kao,
Paul Knowles,
Franz Kottmann,
Eric-Olivier Le Bigot,
Yi-Wei Liu,
José A. M. Lopes,
Livia Ludhova,
Cristina M. B. Monteiro,
Françoise Mulhauser,
Tobias Nebel
, et al. (10 additional authors not shown)
Abstract:
Radiative deexcitation (RD) of the metastable 2S state of muonic protium and deuterium atoms has been observed. In muonic protium, we improve the precision on lifetime and population (formation probability) values for the short-lived μp(2S) component, and give an upper limit for RD of long-lived μp(2S) atoms. In muonic deuterium at 1 hPa, 3.1 +-0.3 % of all stopped muons form μd(2S) atoms. The sho…
▽ More
Radiative deexcitation (RD) of the metastable 2S state of muonic protium and deuterium atoms has been observed. In muonic protium, we improve the precision on lifetime and population (formation probability) values for the short-lived μp(2S) component, and give an upper limit for RD of long-lived μp(2S) atoms. In muonic deuterium at 1 hPa, 3.1 +-0.3 % of all stopped muons form μd(2S) atoms. The short-lived 2S component has a population of 1.35 +0.57 -0.33 % and a lifetime of τ_short(μd) = 138 +32 -34 ns. We see evidence for RD of long-lived μd(2S) with a lifetime of τ_long(μd) = 1.15 +0.75 -0.53 μs. This is interpreted as formation and decay of excited muonic molecules.
△ Less
Submitted 10 October, 2013; v1 submitted 25 July, 2013;
originally announced July 2013.
-
Detailed Report of the MuLan Measurement of the Positive Muon Lifetime and Determination of the Fermi Constant
Authors:
V. Tishchenko,
S. Battu,
R. M. Carey,
D. B. Chitwood,
J. Crnkovic,
P. T. Debevec,
S. Dhamija,
W. Earle,
A. Gafarov,
K. Giovanetti,
T. P. Gorringe,
F. E. Gray,
Z. Hartwig,
D. W. Hertzog,
B. Johnson,
P. Kammel,
B. Kiburg,
S. Kizilgul,
J. Kunkle,
B. Lauss,
I. Logashenko,
K. R. Lynch,
R. McNabb,
J. P. Miller,
F. Mulhauser
, et al. (8 additional authors not shown)
Abstract:
We present a detailed report of the method, setup, analysis and results of a precision measurement of the positive muon lifetime. The experiment was conducted at the Paul Scherrer Institute using a time-structured, nearly 100%-polarized, surface muon beam and a segmented, fast-timing, plastic scintillator array. The measurement employed two target arrangements; a magnetized ferromagnetic target wi…
▽ More
We present a detailed report of the method, setup, analysis and results of a precision measurement of the positive muon lifetime. The experiment was conducted at the Paul Scherrer Institute using a time-structured, nearly 100%-polarized, surface muon beam and a segmented, fast-timing, plastic scintillator array. The measurement employed two target arrangements; a magnetized ferromagnetic target with a ~4 kG internal magnetic field and a crystal quartz target in a 130 G external magnetic field. Approximately 1.6 x 10^{12} positrons were accumulated and together the data yield a muon lifetime of tau_{mu}(MuLan) = 2196980.3(2.2) ps (1.0 ppm), thirty times more precise than previous generations of lifetime experiments. The lifetime measurement yields the most accurate value of the Fermi constant G_F (MuLan) = 1.1663787(6) x 10^{-5} GeV^{-2} (0.5 ppm). It also enables new precision studies of weak interactions via lifetime measurements of muonic atoms.
△ Less
Submitted 5 November, 2012;
originally announced November 2012.
-
Characterization of large area avalanche photodiodes in X-ray and VUV-light detection
Authors:
L. M. P. Fernandes,
F. D. Amaro,
A. Antognini,
J. M. R. Cardoso,
C. A. N. Conde,
O. Huot,
P. E. Knowles,
F. Kottmann,
J. A. M. Lopes,
L. Ludhova,
C. M. B. Monteiro,
F. Mulhauser,
R. Pohl,
J. M. F. dos Santos,
L. A. Schaller,
D. Taqqu,
J. F. C. A. Veloso
Abstract:
The present manuscript summarizes novel studies on the application of large area avalanche photodiodes (LAAPDs) to the detection of X-rays and vacuum ultraviolet (VUV) light. The operational characteristics of four different LAAPDs manufactured by Advanced Photonix Inc., with active areas of 80 and 200 mm^2 were investigated for X-ray detection at room temperature. The best energy resolution was…
▽ More
The present manuscript summarizes novel studies on the application of large area avalanche photodiodes (LAAPDs) to the detection of X-rays and vacuum ultraviolet (VUV) light. The operational characteristics of four different LAAPDs manufactured by Advanced Photonix Inc., with active areas of 80 and 200 mm^2 were investigated for X-ray detection at room temperature. The best energy resolution was found to be in the 10-18% range for 5.9 keV X-rays. The LAAPD, being compact, simple to operate and with high counting rate capability (up to about 10^5/s), proved to be useful in several applications, such as low-energy X-ray detection, where they can reach better performance than proportional counters. Since X-rays are used as reference in light measurements, the gain non-linearity between 5.9 keV X-rays and light pulses was investigated. The gain ratio between X-rays and VUV light decreases with gain, reaching 10 and 6% variations for VUV light produced in argon (~128 nm) and xenon (~172 nm), respectively, for a gain 200, while for visible light (~635 nm) the variation is lower than 1%. The effect of temperature on the LAAPD performance was investigated. Relative gain variations of about -5% per Celsius degree were observed for the highest gains. The excess noise factor was found to be independent on temperature, being between 1.8 and 2.3 for gains from 50 to 300. The energy resolution is better for decreasing temperatures due mainly to the dark current. LAAPDs were tested under intense magnetic fields up to 5 T, being insensitive when used in X-ray and visible-light detection, while for VUV light a significant amplitude reduction was observed at 5 T.
△ Less
Submitted 15 February, 2007;
originally announced February 2007.
-
Muonic hydrogen cascade time and lifetime of the short-lived $2S$ state
Authors:
L. Ludhova,
F. D. Amaro,
A. Antognini,
F. Biraben,
J. M. R. Cardoso,
C. A. N. Conde,
A. Dax,
S. Dhawan,
L. M. P. Fernandes,
T. W. Haensch,
V. W. Hughes,
P. Indelicato,
L. Julien,
P. E. Knowles,
F. Kottmann,
Y. -W. Liu,
J. A. M. Lopes,
C. M. B. Monteiro,
F. Mulhauser,
F. Nez,
R. Pohl,
P. Rabinowitz,
J. M. F. dos Santos,
L. A. Schaller,
C. Schwob
, et al. (2 additional authors not shown)
Abstract:
Metastable ${2S}$ muonic-hydrogen atoms undergo collisional ${2S}$-quenching, with rates which depend strongly on whether the $μp$ kinetic energy is above or below the ${2S}\to {2P}$ energy threshold. Above threshold, collisional ${2S} \to {2P}$ excitation followed by fast radiative ${2P} \to {1S}$ deexcitation is allowed. The corresponding short-lived $μp ({2S})$ component was measured at 0.6 h…
▽ More
Metastable ${2S}$ muonic-hydrogen atoms undergo collisional ${2S}$-quenching, with rates which depend strongly on whether the $μp$ kinetic energy is above or below the ${2S}\to {2P}$ energy threshold. Above threshold, collisional ${2S} \to {2P}$ excitation followed by fast radiative ${2P} \to {1S}$ deexcitation is allowed. The corresponding short-lived $μp ({2S})$ component was measured at 0.6 hPa $\mathrm{H}_2$ room temperature gas pressure, with lifetime $τ_{2S}^\mathrm{short} = 165 ^{+38}_{-29}$ ns (i.e., $λ_{2S}^\mathrm{quench} = 7.9 ^{+1.8}_{-1.6} \times 10^{12} \mathrm{s}^{-1}$ at liquid-hydrogen density) and population $ε_{2S}^\mathrm{short} = 1.70^{+0.80}_{-0.56}$ % (per $μp$ atom). In addition, a value of the $μp$ cascade time, $T_\mathrm{cas}^{μp} = (37\pm5)$ ns, was found.
△ Less
Submitted 13 November, 2006;
originally announced November 2006.
-
Planar LAAPDs: Temperature Dependence, Performance, and Application in Low Energy X-ray Spectroscopy
Authors:
L. Ludhova,
F. D. Amaro,
A. Antognini,
F. Biraben,
J. M. R. Cardoso,
C. A. N. Conde,
D. S. Covita,
A. Dax,
S. Dhawan,
L. M. P. Fernandes,
T. W. Hansch,
V. W. Hughes,
O. Huot,
P. Indelicato,
L. Julien,
P. E. Knowles,
F. Kottmann,
J. A. M. Lopes,
Y. -W. Liu,
C. M. B. Monteiro,
F. Mulhauser,
F. Nez,
R. Pohl,
P. Rabinowitz,
J. M. F. dos Santos
, et al. (3 additional authors not shown)
Abstract:
An experiment measuring the 2S Lamb shift in muonic hydrogen mup is being performed at the Paul Scherrer Institute, Switzerland. It requires small and compact detectors for 1.9 keV x rays (2P-1S transition) with an energy resolution around 25% at 2 keV, a time resolution better than 100 ns, a large solid angle coverage, and insensitivity to a 5 T magnetic field. We have chosen Large Area Avalanc…
▽ More
An experiment measuring the 2S Lamb shift in muonic hydrogen mup is being performed at the Paul Scherrer Institute, Switzerland. It requires small and compact detectors for 1.9 keV x rays (2P-1S transition) with an energy resolution around 25% at 2 keV, a time resolution better than 100 ns, a large solid angle coverage, and insensitivity to a 5 T magnetic field. We have chosen Large Area Avalanche Photodiodes (LAAPDs) from Radiation Monitoring Devices as x-ray detectors, and they were used during the last data taking period in 2003. For x-ray spectroscopy applications, these LAAPDs have to be cooled in order to suppress the dark current noise, hence, a series of tests were performed to choose the optimal operation temperature. Specifically, the temperature dependence of gain, energy resolution, dark current, excess noise factor, and detector response linearity was studied. Finally, details of the LAAPDs application in the muonic hydrogen experiment as well as their response to alpha particles are presented.
△ Less
Submitted 15 October, 2004;
originally announced October 2004.
-
Resonant Scattering of Muonic Hydrogen Atoms and Dynamics of Muonic Molecular Complex
Authors:
TRIUMF Munoic Hydrogen Collaboration,
M. C. Fujiwara,
A. Adamczak,
J. M. Bailey,
G. A. Beer,
J. L. Beveridge,
M. P. Faifman,
T. M. Huber,
P. Kammel,
S. K. Kim,
P. E. Knowles,
A. R. Kunselman,
M. Maier,
V. E. Markushin,
G. M. Marshall,
C. J. Martoff,
G. R. Mason,
F. Mulhauser,
A. Olin,
C. Petitjean,
T. A. Porcelli,
J. Wozniak,
J. Zmeskal
Abstract:
Resonant scattering of muonic hydrogen atoms via back decay of molecular complex, a key process in the understanding of epithermal muonic molecular formation, is analyzed. The limitations of the effective rate approximation are discussed and the importance of the explicit treatment of the back decay is stressed. An expression of the energy distribution for the back-decayed atoms is given.
Resonant scattering of muonic hydrogen atoms via back decay of molecular complex, a key process in the understanding of epithermal muonic molecular formation, is analyzed. The limitations of the effective rate approximation are discussed and the importance of the explicit treatment of the back decay is stressed. An expression of the energy distribution for the back-decayed atoms is given.
△ Less
Submitted 29 November, 2001;
originally announced November 2001.
-
Measurement of the Resonant $dμt$ Molecular Formation Rate in Solid HD
Authors:
T. A. Porcelli,
A. Adamczak,
J. M. Bailey,
G. A. Beer,
J. L. Douglas,
M. P. Faifman,
M. C. Fujiwara,
T. M. Huber,
P. Kammel,
S. K. Kim,
P. E. Knowles,
A. R. Kunselman,
M. Maier,
V. E. Mar kushin,
G. M. Marshall,
G. R. Mason,
F. Mulhauser,
A. Olin,
C. Petitjean,
J. Zmeskal
Abstract:
Measurements of muon-catalyzed dt fusion ($dμt \to ^4He+n+μ^-$) in solid HD have been performed. The theory describing the energy dependent resonant molecular formation rate for the reaction $μt$ + HD $\to [(dμt)pee]^*$ is compared to experimental results in a pure solid HD target. Constraints on the rates are inferred through the use of a Monte Carlo model developed specifically for the experim…
▽ More
Measurements of muon-catalyzed dt fusion ($dμt \to ^4He+n+μ^-$) in solid HD have been performed. The theory describing the energy dependent resonant molecular formation rate for the reaction $μt$ + HD $\to [(dμt)pee]^*$ is compared to experimental results in a pure solid HD target. Constraints on the rates are inferred through the use of a Monte Carlo model developed specifically for the experiment. From the time-of- flight analysis of fusion events in 16 and 37 $μg\cdot cm^{-2}$ targets, an average formation rate consistent with 0.897$\pm$(0.046)$_{stat}\pm$ (0.166)$_{syst}$ times the theoretical prediction was obtained.
△ Less
Submitted 2 April, 2001;
originally announced April 2001.
-
Time-of-Flight Spectroscopy of Muonic Hydrogen Atoms and Molecules
Authors:
TRIUMF Muonic Hydrogen Collaboration,
M. C. Fujiwara,
A. Adamczak,
J. M. Bailey,
G. A. Beer,
J. L. Beveridge,
M. P. Faifman,
T. M. Huber,
P. Kammel,
S. K. Kim,
P. E. Knowles,
A. R. Kunselman,
V. E. Markushin,
G. M. Marshall,
G. R. Mason,
F. Mulhauser,
A. Olin,
C. Petitjean,
T. A. Porcelli,
J. Zmeskal
Abstract:
Studies of muonic hydrogen atoms and molecules have been performed traditionally in bulk targets of gas, liquid or solid. At TRIUMF, Canada's meson facility, we have developed a new type of target system using multilayer thin films of solid hydrogen, which provides a beam of muonic hydrogen atoms in vacuum. Using the time-of-flight of the muonic atoms, the energy-dependent information of muonic…
▽ More
Studies of muonic hydrogen atoms and molecules have been performed traditionally in bulk targets of gas, liquid or solid. At TRIUMF, Canada's meson facility, we have developed a new type of target system using multilayer thin films of solid hydrogen, which provides a beam of muonic hydrogen atoms in vacuum. Using the time-of-flight of the muonic atoms, the energy-dependent information of muonic reactions are obtained in direct manner. We discuss some unique measurements enabled by the new technique, with emphasis on processes relevant to muon catalyzed fusion.
△ Less
Submitted 22 January, 2001;
originally announced January 2001.
-
Using Thin Film Targets for Muonic Atoms and Muon Catalyzed Fusion Studies
Authors:
TRIUMF Munoic Hydrogen Collaboration,
M. C. Fujiwara,
A. Adamczak,
J. M. Bailey,
G. A. Beer,
J. L. Beveridge,
M. P. Faifman,
T. M. Huber,
P. Kammel,
S. K. Kim,
P. E. Knowles,
A. R. Kunselman,
V. E. Markushin,
G. M. Marshall,
C. J. Martoff,
G. R. Mason,
F. Mulhauser,
A. Olin,
C. Petitjean,
T. A. Porcelli,
J. Zmeskal
Abstract:
Studies of muonic atoms and muon catalyzed fusion have been conventionally done in a bulk target of gas, liquid or solid hydrogen isotopes. The use of thin film targets developed at TRIUMF have notable advantages in tackling some of the most important questions in the field, which could be further exploited at future high intensity muon sources. We review the technique of the thin film method wi…
▽ More
Studies of muonic atoms and muon catalyzed fusion have been conventionally done in a bulk target of gas, liquid or solid hydrogen isotopes. The use of thin film targets developed at TRIUMF have notable advantages in tackling some of the most important questions in the field, which could be further exploited at future high intensity muon sources. We review the technique of the thin film method with emphasis on recent results and a future proposal.
△ Less
Submitted 3 September, 2000;
originally announced September 2000.
-
Resonant Formation of $dμt$ Molecules in Deuterium: An Atomic Beam Measurement of Muon Catalyzed dt Fusion
Authors:
TRIUMF Munoic Hydrogen Collaboration,
M. C. Fujiwara,
A. Adamczak,
J. M. Bailey,
G. A. Beer,
J. L. Beveridge,
M. P. Faifman,
T. M. Huber,
P. Kammel,
S. K. Kim,
P. E. Knowles,
A. R. Kunselman,
M. Maier,
V. E. Markushin,
G. M. Marshall,
C. J. Martoff,
G. R. Mason,
F. Mulhauser,
A. Olin,
C. Petitjean,
T. A. Porcelli,
J. Wozniak,
J. Zmeskal
Abstract:
Resonant formation of $dμt$ molecules in collisions of muonic tritium ($μt$) on D$_2$ was investigated using a beam of $μt$ atoms, demonstrating a new direct approach in muon catalyzed fusion studies. Strong epithermal resonances in $dμt$ formation were directly revealed for the first time. From the time-of-flight analysis of $2036\pm 116$ $dt$ fusion events, a formation rate consistent with…
▽ More
Resonant formation of $dμt$ molecules in collisions of muonic tritium ($μt$) on D$_2$ was investigated using a beam of $μt$ atoms, demonstrating a new direct approach in muon catalyzed fusion studies. Strong epithermal resonances in $dμt$ formation were directly revealed for the first time. From the time-of-flight analysis of $2036\pm 116$ $dt$ fusion events, a formation rate consistent with $0.73\pm (0.16)_{meas} \pm (0.09)_{model}$ times the theoretical prediction was obtained. For the largest peak at a resonance energy of $0.423 \pm 0.037$ eV, this corresponds to a rate of $(7.1 \pm 1.8) \times 10^9$ s$^{-1}$, more than an order of magnitude larger than those at low energies.
△ Less
Submitted 6 August, 2000;
originally announced August 2000.