-
STCF Conceptual Design Report: Volume 1 -- Physics & Detector
Authors:
M. Achasov,
X. C. Ai,
R. Aliberti,
L. P. An,
Q. An,
X. Z. Bai,
Y. Bai,
O. Bakina,
A. Barnyakov,
V. Blinov,
V. Bobrovnikov,
D. Bodrov,
A. Bogomyagkov,
A. Bondar,
I. Boyko,
Z. H. Bu,
F. M. Cai,
H. Cai,
J. J. Cao,
Q. H. Cao,
Z. Cao,
Q. Chang,
K. T. Chao,
D. Y. Chen,
H. Chen
, et al. (413 additional authors not shown)
Abstract:
The Super $τ$-Charm facility (STCF) is an electron-positron collider proposed by the Chinese particle physics community. It is designed to operate in a center-of-mass energy range from 2 to 7 GeV with a peak luminosity of $0.5\times 10^{35}{\rm cm}^{-2}{\rm s}^{-1}$ or higher. The STCF will produce a data sample about a factor of 100 larger than that by the present $τ$-Charm factory -- the BEPCII,…
▽ More
The Super $τ$-Charm facility (STCF) is an electron-positron collider proposed by the Chinese particle physics community. It is designed to operate in a center-of-mass energy range from 2 to 7 GeV with a peak luminosity of $0.5\times 10^{35}{\rm cm}^{-2}{\rm s}^{-1}$ or higher. The STCF will produce a data sample about a factor of 100 larger than that by the present $τ$-Charm factory -- the BEPCII, providing a unique platform for exploring the asymmetry of matter-antimatter (charge-parity violation), in-depth studies of the internal structure of hadrons and the nature of non-perturbative strong interactions, as well as searching for exotic hadrons and physics beyond the Standard Model. The STCF project in China is under development with an extensive R\&D program. This document presents the physics opportunities at the STCF, describes conceptual designs of the STCF detector system, and discusses future plans for detector R\&D and physics case studies.
△ Less
Submitted 5 October, 2023; v1 submitted 28 March, 2023;
originally announced March 2023.
-
Beam dynamics corrections to the Run-1 measurement of the muon anomalous magnetic moment at Fermilab
Authors:
T. Albahri,
A. Anastasi,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
G. Cantatore,
R. M. Carey,
B. C. K. Casey,
D. Cauz,
R. Chakraborty,
S. P. Chang,
A. Chapelain,
S. Charity,
R. Chislett
, et al. (152 additional authors not shown)
Abstract:
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is fe…
▽ More
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is felt by relativistic muons passing transversely through the radial electric field components created by the ESQ system. The correction depends on the stored momentum distribution and the tunes of the ring, which has relatively weak vertical focusing. Vertical betatron motions imply that the muons do not orbit the ring in a plane exactly orthogonal to the vertical magnetic field direction. A correction is necessary to account for an average pitch angle associated with their trajectories. A third small correction is necessary because muons that escape the ring during the storage time are slightly biased in initial spin phase compared to the parent distribution. Finally, because two high-voltage resistors in the ESQ network had longer than designed RC time constants, the vertical and horizontal centroids and envelopes of the stored muon beam drifted slightly, but coherently, during each storage ring fill. This led to the discovery of an important phase-acceptance relationship that requires a correction. The sum of the corrections to $ω_a^m$ is 0.50 $\pm$ 0.09 ppm; the uncertainty is small compared to the 0.43 ppm statistical precision of $ω_a^m$.
△ Less
Submitted 23 April, 2021; v1 submitted 7 April, 2021;
originally announced April 2021.
-
Charged particle identification with the liquid xenon calorimeter of the CMD-3 detector
Authors:
V. L. Ivanov,
G. V. Fedotovich,
R. R. Akhmetshin,
A. N. Amirkhanov,
A. V. Anisenkov,
V. M. Aulchenko,
N. S. Bashtovoy,
A. E. Bondar,
A. V. Bragin,
S. I. Eidelman,
D. A. Epifanov,
L. B. Epshteyn,
A. L. Erofeev,
S. E. Gayazov,
A. A. Grebenuk,
S. S. Gribanov,
D. N. Grigoriev,
F. V. Ignatov,
S. V. Karpov,
V. F. Kazanin,
A. A. Korobov,
A. N. Kozyrev,
E. A. Kozyrev,
P. P. Krokovny,
A. E. Kuzmenko
, et al. (21 additional authors not shown)
Abstract:
The paper describes a method of the charged particle identification, developed for the \mbox{CMD-3} detector, installed at the VEPP-2000 $e^{+}e^{-}$ collider. The method is based on the application of the boosted decision trees classifiers, trained for the optimal separation of electrons, muons, pions and kaons in the momentum range from 100 to $1200~{\rm MeV}/c$. The input variables for the clas…
▽ More
The paper describes a method of the charged particle identification, developed for the \mbox{CMD-3} detector, installed at the VEPP-2000 $e^{+}e^{-}$ collider. The method is based on the application of the boosted decision trees classifiers, trained for the optimal separation of electrons, muons, pions and kaons in the momentum range from 100 to $1200~{\rm MeV}/c$. The input variables for the classifiers are linear combinations of the energy depositions of charged particles in 12 layers of the liquid xenon calorimeter of the \mbox{CMD-3}. The event samples for training of the classifiers are taken from the simulation. Various issues of the detector response tuning in simulation and calibration of the calorimeter strip channels are considered. Application of the method is illustrated by the examples of separation of the $e^+e^-(γ)$ and $π^+π^-(γ)$ final states and of selection of the $K^+K^-$ final state at high energies.
△ Less
Submitted 12 August, 2020;
originally announced August 2020.
-
Expression of Interest for Evolution of the Mu2e Experiment
Authors:
F. Abusalma,
D. Ambrose,
A. Artikov,
R. Bernstein,
G. C. Blazey,
C. Bloise,
S. Boi,
T. Bolton,
J. Bono,
R. Bonventre,
D. Bowring,
D. Brown,
D. Brown,
K. Byrum,
M. Campbell,
J. -F. Caron,
F. Cervelli,
D. Chokheli,
K. Ciampa,
R. Ciolini,
R. Coleman,
D. Cronin-Hennessy,
R. Culbertson,
M. A. Cummings,
A. Daniel
, et al. (103 additional authors not shown)
Abstract:
We propose an evolution of the Mu2e experiment, called Mu2e-II, that would leverage advances in detector technology and utilize the increased proton intensity provided by the Fermilab PIP-II upgrade to improve the sensitivity for neutrinoless muon-to-electron conversion by one order of magnitude beyond the Mu2e experiment, providing the deepest probe of charged lepton flavor violation in the fores…
▽ More
We propose an evolution of the Mu2e experiment, called Mu2e-II, that would leverage advances in detector technology and utilize the increased proton intensity provided by the Fermilab PIP-II upgrade to improve the sensitivity for neutrinoless muon-to-electron conversion by one order of magnitude beyond the Mu2e experiment, providing the deepest probe of charged lepton flavor violation in the foreseeable future. Mu2e-II will use as much of the Mu2e infrastructure as possible, providing, where required, improvements to the Mu2e apparatus to accommodate the increased beam intensity and cope with the accompanying increase in backgrounds.
△ Less
Submitted 7 February, 2018;
originally announced February 2018.
-
Muon (g-2) Technical Design Report
Authors:
J. Grange,
V. Guarino,
P. Winter,
K. Wood,
H. Zhao,
R. M. Carey,
D. Gastler,
E. Hazen,
N. Kinnaird,
J. P. Miller,
J. Mott,
B. L. Roberts,
J. Benante,
J. Crnkovic,
W. M. Morse,
H. Sayed,
V. Tishchenko,
V. P. Druzhinin,
B. I. Khazin,
I. A. Koop,
I. Logashenko,
Y. M. Shatunov,
E. Solodov,
M. Korostelev,
D. Newton
, et al. (176 additional authors not shown)
Abstract:
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should…
▽ More
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should be able to determine definitively whether or not the E821 result is evidence for physics beyond the Standard Model. After a review of the physics motivation and the basic technique, which will use the muon storage ring built at BNL and now relocated to Fermilab, the design of the new experiment is presented. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-2/3 approval.
△ Less
Submitted 11 May, 2018; v1 submitted 27 January, 2015;
originally announced January 2015.
-
Detailed Report of the MuLan Measurement of the Positive Muon Lifetime and Determination of the Fermi Constant
Authors:
V. Tishchenko,
S. Battu,
R. M. Carey,
D. B. Chitwood,
J. Crnkovic,
P. T. Debevec,
S. Dhamija,
W. Earle,
A. Gafarov,
K. Giovanetti,
T. P. Gorringe,
F. E. Gray,
Z. Hartwig,
D. W. Hertzog,
B. Johnson,
P. Kammel,
B. Kiburg,
S. Kizilgul,
J. Kunkle,
B. Lauss,
I. Logashenko,
K. R. Lynch,
R. McNabb,
J. P. Miller,
F. Mulhauser
, et al. (8 additional authors not shown)
Abstract:
We present a detailed report of the method, setup, analysis and results of a precision measurement of the positive muon lifetime. The experiment was conducted at the Paul Scherrer Institute using a time-structured, nearly 100%-polarized, surface muon beam and a segmented, fast-timing, plastic scintillator array. The measurement employed two target arrangements; a magnetized ferromagnetic target wi…
▽ More
We present a detailed report of the method, setup, analysis and results of a precision measurement of the positive muon lifetime. The experiment was conducted at the Paul Scherrer Institute using a time-structured, nearly 100%-polarized, surface muon beam and a segmented, fast-timing, plastic scintillator array. The measurement employed two target arrangements; a magnetized ferromagnetic target with a ~4 kG internal magnetic field and a crystal quartz target in a 130 G external magnetic field. Approximately 1.6 x 10^{12} positrons were accumulated and together the data yield a muon lifetime of tau_{mu}(MuLan) = 2196980.3(2.2) ps (1.0 ppm), thirty times more precise than previous generations of lifetime experiments. The lifetime measurement yields the most accurate value of the Fermi constant G_F (MuLan) = 1.1663787(6) x 10^{-5} GeV^{-2} (0.5 ppm). It also enables new precision studies of weak interactions via lifetime measurements of muonic atoms.
△ Less
Submitted 5 November, 2012;
originally announced November 2012.