Beam-Based Diagnostics of Electric Guide Fields and Lattice Parameters for Run-1 of the Muon g-2 Storage Ring at Fermilab
Authors:
David Tarazona,
Martin Berz,
Jason Crnkovic,
Kim-Siang Khaw,
Kyoko Makino,
James Mott,
Joseph Price,
Michael Syphers,
Vladimir Tishchenko
Abstract:
A portion of the Muon g-2 Storage Ring electric system, which provides vertical beam focusing, exhibited an unexpected time dependence that produced a characteristic evolution of the stored beam during Run-1 of the Muon g-2 Experiment at Fermilab (E989). A method to reconstruct the Run-1 electric guide fields has been developed, which is based on a numerical model of the muon storage ring and opti…
▽ More
A portion of the Muon g-2 Storage Ring electric system, which provides vertical beam focusing, exhibited an unexpected time dependence that produced a characteristic evolution of the stored beam during Run-1 of the Muon g-2 Experiment at Fermilab (E989). A method to reconstruct the Run-1 electric guide fields has been developed, which is based on a numerical model of the muon storage ring and optimization algorithms supported by COSY INFINITY. This method takes beam profile measurements from the Muon g-2 straw tracking detectors as input, and it produces a full reconstruction of the time-dependent fields. The fields can then be used for the reproduction of detailed beam tracking simulations and the calculation of ring lattice parameters for acceptance studies and systematic error evaluations.
△ Less
Submitted 16 November, 2022;
originally announced November 2022.
-
Testing Lepton Flavor Universality and CKM Unitarity with Rare Pion Decays in the PIONEER experiment
Authors:
PIONEER Collaboration,
W. Altmannshofer,
H. Binney,
E. Blucher,
D. Bryman,
L. Caminada,
S. Chen,
V. Cirigliano,
S. Corrodi,
A. Crivellin,
S. Cuen-Rochin,
A. Di Canto,
L. Doria,
A. Gaponenko,
A. Garcia,
L. Gibbons,
C. Glaser,
M. Escobar Godoy,
D. Göldi,
S. Gori,
T. Gorringe,
D. Hertzog,
Z. Hodge,
M. Hoferichter,
S. Ito
, et al. (36 additional authors not shown)
Abstract:
The physics motivation and the conceptual design of the PIONEER experiment, a next-generation rare pion decay experiment testing lepton flavor universality and CKM unitarity, are described. Phase I of the PIONEER experiment, which was proposed and approved at Paul Scherrer Institut, aims at measuring the charged-pion branching ratio to electrons vs.\ muons, $R_{e/μ}$, 15 times more precisely than…
▽ More
The physics motivation and the conceptual design of the PIONEER experiment, a next-generation rare pion decay experiment testing lepton flavor universality and CKM unitarity, are described. Phase I of the PIONEER experiment, which was proposed and approved at Paul Scherrer Institut, aims at measuring the charged-pion branching ratio to electrons vs.\ muons, $R_{e/μ}$, 15 times more precisely than the current experimental result, reaching the precision of the Standard Model (SM) prediction at 1 part in $10^4$. Considering several inconsistencies between the SM predictions and data pointing towards the potential violation of lepton flavor universality, the PIONEER experiment will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles up to the PeV mass scale. The later phases of the PIONEER experiment aim at improving the experimental precision of the branching ratio of pion beta decay (BRPB), $π^+\to π^0 e^+ ν(γ)$, currently at $1.036(6)\times10^{-8}$, by a factor of three (Phase II) and an order of magnitude (Phase III). Such precise measurements of BRPB will allow for tests of CKM unitarity in light of the Cabibbo Angle Anomaly and the theoretically cleanest extraction of $|V_{ud}|$ at the 0.02\% level, comparable to the deduction from superallowed beta decays.
△ Less
Submitted 10 March, 2022;
originally announced March 2022.
-
PIONEER: Studies of Rare Pion Decays
Authors:
PIONEER Collaboration,
W. Altmannshofer,
H. Binney,
E. Blucher,
D. Bryman,
L. Caminada,
S. Chen,
V. Cirigliano,
S. Corrodi,
A. Crivellin,
S. Cuen-Rochin,
A. DiCanto,
L. Doria,
A. Gaponenko,
A. Garcia,
L. Gibbons,
C. Glaser,
M. Escobar Godoy,
D. Göldi,
S. Gori,
T. Gorringe,
D. Hertzog,
Z. Hodge,
M. Hoferichter,
S. Ito
, et al. (36 additional authors not shown)
Abstract:
A next-generation rare pion decay experiment, PIONEER, is strongly motivated by several inconsistencies between Standard Model (SM) predictions and data pointing towards the potential violation of lepton flavor universality. It will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles even if their masses are at very high scales. Measurement of the c…
▽ More
A next-generation rare pion decay experiment, PIONEER, is strongly motivated by several inconsistencies between Standard Model (SM) predictions and data pointing towards the potential violation of lepton flavor universality. It will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles even if their masses are at very high scales. Measurement of the charged-pion branching ratio to electrons vs. muons $R_{e/μ}$ is extremely sensitive to new physics effects. At present, the SM prediction for $R_{e/μ}$ is known to 1 part in $10^4$, which is 15 times more precise than the current experimental result. An experiment reaching the theoretical accuracy will test lepton flavor universality at an unprecedented level, probing mass scales up to the PeV range. Measurement of pion beta decay, $π^+\to π^0 e^+ ν(γ)$, with 3 to 10-fold improvement in sensitivity, will determine $V_{ud}$ in a theoretically pristine manner and test CKM unitarity, which is very important in light of the recently emerged tensions. In addition, various exotic rare decays involving sterile neutrinos and axions will be searched for with unprecedented sensitivity. The experiment design benefits from experience with the recent PIENU and PEN experiments at TRIUMF and the Paul Scherrer Institut (PSI). Excellent energy and time resolutions, greatly increased calorimeter depth, high-speed detector and electronics response, large solid angle coverage, and complete event reconstruction are all critical aspects of the approach. The PIONEER experiment design includes a 3$π$ sr 25 radiation length calorimeter, a segmented low gain avalanche detector stopping target, a positron tracker, and other detectors. Using intense pion beams, and state-of-the-art instrumentation and computational resources, the experiments can be performed at the PSI ring cyclotron.
△ Less
Submitted 7 March, 2022; v1 submitted 3 March, 2022;
originally announced March 2022.
-
The Straw Tracking Detector for the Fermilab Muon $g-2$ Experiment
Authors:
B. T. King,
T. Albahri,
S. Al-Kilani,
D. Allspach,
D. Beckner,
A. Behnke,
T. J. V. Bowcock,
D. Boyden,
R. M. Carey,
J. Carroll,
B. C. K. Casey,
S. Charity,
R. Chislett,
M. Eads,
A. Epps,
S. B. Foster,
D. Gastler,
S. Grant,
T. Halewood-Leagas,
K. Hardin,
E. Hazen,
G. Hesketh,
D. J. Hollywood,
T. Jones,
C. Kenziora
, et al. (32 additional authors not shown)
Abstract:
The Muon $g-2$ Experiment at Fermilab uses a gaseous straw tracking detector to make detailed measurements of the stored muon beam profile, which are essential for the experiment to achieve its uncertainty goals. Positrons from muon decays spiral inward and pass through the tracking detector before striking an electromagnetic calorimeter. The tracking detector is therefore located inside the vacuu…
▽ More
The Muon $g-2$ Experiment at Fermilab uses a gaseous straw tracking detector to make detailed measurements of the stored muon beam profile, which are essential for the experiment to achieve its uncertainty goals. Positrons from muon decays spiral inward and pass through the tracking detector before striking an electromagnetic calorimeter. The tracking detector is therefore located inside the vacuum chamber in a region where the magnetic field is large and non-uniform. As such, the tracking detector must have a low leak rate to maintain a high-quality vacuum, must be non-magnetic so as not to perturb the magnetic field and, to minimize energy loss, must have a low radiation length. The performance of the tracking detector has met or surpassed the design requirements, with adequate electronic noise levels, an average straw hit resolution of $(110 \pm 20) \,μ$m, a detection efficiency of 97% or higher, and no performance degradation or signs of aging. The tracking detector's measurements result in an otherwise unachievable understanding of the muon's beam motion, particularly at early times in the experiment's measurement period when there are a significantly greater number of muons decaying. This is vital to the statistical power of the experiment, as well as facilitating the precise extraction of several systematic corrections and uncertainties. This paper describes the design, construction, testing, commissioning, and performance of the tracking detector.
△ Less
Submitted 24 February, 2022; v1 submitted 3 November, 2021;
originally announced November 2021.
-
Beam dynamics corrections to the Run-1 measurement of the muon anomalous magnetic moment at Fermilab
Authors:
T. Albahri,
A. Anastasi,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
G. Cantatore,
R. M. Carey,
B. C. K. Casey,
D. Cauz,
R. Chakraborty,
S. P. Chang,
A. Chapelain,
S. Charity,
R. Chislett
, et al. (152 additional authors not shown)
Abstract:
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is fe…
▽ More
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is felt by relativistic muons passing transversely through the radial electric field components created by the ESQ system. The correction depends on the stored momentum distribution and the tunes of the ring, which has relatively weak vertical focusing. Vertical betatron motions imply that the muons do not orbit the ring in a plane exactly orthogonal to the vertical magnetic field direction. A correction is necessary to account for an average pitch angle associated with their trajectories. A third small correction is necessary because muons that escape the ring during the storage time are slightly biased in initial spin phase compared to the parent distribution. Finally, because two high-voltage resistors in the ESQ network had longer than designed RC time constants, the vertical and horizontal centroids and envelopes of the stored muon beam drifted slightly, but coherently, during each storage ring fill. This led to the discovery of an important phase-acceptance relationship that requires a correction. The sum of the corrections to $ω_a^m$ is 0.50 $\pm$ 0.09 ppm; the uncertainty is small compared to the 0.43 ppm statistical precision of $ω_a^m$.
△ Less
Submitted 23 April, 2021; v1 submitted 7 April, 2021;
originally announced April 2021.
-
Measurement of the distribution of $^{207}$Bi depositions on calibration sources for SuperNEMO
Authors:
R. Arnold,
C. Augier,
A. S. Barabash,
A. Basharina-Freshville,
E. Birdsall,
S. Blondel,
M. Bongrand,
D. Boursette,
R. Breier,
V. Brudanin,
J. Busto,
S. Calvez,
C. Cerna,
J. P. Cesar,
M. Ceschia,
A. Chapon,
E. Chauveau,
A. Chopra,
L. Dawson,
S. De Capua,
D. Duchesneau,
D. Durand,
G. Eurin,
J. J. Evans,
D. Filosofov
, et al. (75 additional authors not shown)
Abstract:
The SuperNEMO experiment will search for neutrinoless double-beta decay ($0νββ$), and study the Standard-Model double-beta decay process ($2νββ$). The SuperNEMO technology can measure the energy of each of the electrons produced in a double-beta ($ββ$) decay, and can reconstruct the topology of their individual tracks. The study of the double-beta decay spectrum requires very accurate energy calib…
▽ More
The SuperNEMO experiment will search for neutrinoless double-beta decay ($0νββ$), and study the Standard-Model double-beta decay process ($2νββ$). The SuperNEMO technology can measure the energy of each of the electrons produced in a double-beta ($ββ$) decay, and can reconstruct the topology of their individual tracks. The study of the double-beta decay spectrum requires very accurate energy calibration to be carried out periodically. The SuperNEMO Demonstrator Module will be calibrated using 42 calibration sources, each consisting of a droplet of $^{207}$Bi within a frame assembly.
The quality of these sources, which depends upon the entire $^{207}$Bi droplet being contained within the frame, is key for correctly calibrating SuperNEMO's energy response. In this paper, we present a novel method for precisely measuring the exact geometry of the deposition of $^{207}$Bi droplets within the frames, using Timepix pixel detectors. We studied 49 different sources and selected 42 high-quality sources with the most central source positioning.
△ Less
Submitted 20 May, 2021; v1 submitted 26 March, 2021;
originally announced March 2021.
-
Search for the double-beta decay of 82Se to the excited states of 82Kr with NEMO-3
Authors:
The NEMO-3 collaboration R. Arnold,
C. Augier,
A. S. Barabash,
A. Basharina-Freshville,
S. Blondel,
S. Blot,
M. Bongrand,
D. Boursette,
R. Breier,
V. Brudanin,
J. Busto,
A. J. Caffrey,
S. Calvez,
M. Cascella,
C. Cerna,
J. P. Cesar,
A. Chapon,
E. Chauveau,
A. Chopra,
L. Dawson,
D. Duchesneau,
D. Durand,
V. Egorov,
G. Eurin,
J. J. Evans
, et al. (82 additional authors not shown)
Abstract:
The double-beta decay of 82Se to the 0+1 excited state of 82Kr has been studied with the NEMO-3 detector using 0.93 kg of enriched 82Se measured for 4.75 y, corresponding to an exposure of 4.42 kg y. A dedicated analysis to reconstruct the gamma-rays has been performed to search for events in the 2e2g channel. No evidence of a 2nbb decay to the 0+1 state has been observed and a limit of T2n 1/2(82…
▽ More
The double-beta decay of 82Se to the 0+1 excited state of 82Kr has been studied with the NEMO-3 detector using 0.93 kg of enriched 82Se measured for 4.75 y, corresponding to an exposure of 4.42 kg y. A dedicated analysis to reconstruct the gamma-rays has been performed to search for events in the 2e2g channel. No evidence of a 2nbb decay to the 0+1 state has been observed and a limit of T2n 1/2(82Se; 0+gs -> 0+1) > 1.3 1021 y at 90% CL has been set. Concerning the 0nbb decay to the 0+1 state, a limit for this decay has been obtained with T0n 1/2(82Se; 0+g s -> 0+1) > 2.3 1022 y at 90% CL, independently from the 2nbb decay process. These results are obtained for the first time with a tracko-calo detector, reconstructing every particle in the final state.
△ Less
Submitted 17 January, 2020;
originally announced January 2020.
-
Expression of Interest for Evolution of the Mu2e Experiment
Authors:
F. Abusalma,
D. Ambrose,
A. Artikov,
R. Bernstein,
G. C. Blazey,
C. Bloise,
S. Boi,
T. Bolton,
J. Bono,
R. Bonventre,
D. Bowring,
D. Brown,
D. Brown,
K. Byrum,
M. Campbell,
J. -F. Caron,
F. Cervelli,
D. Chokheli,
K. Ciampa,
R. Ciolini,
R. Coleman,
D. Cronin-Hennessy,
R. Culbertson,
M. A. Cummings,
A. Daniel
, et al. (103 additional authors not shown)
Abstract:
We propose an evolution of the Mu2e experiment, called Mu2e-II, that would leverage advances in detector technology and utilize the increased proton intensity provided by the Fermilab PIP-II upgrade to improve the sensitivity for neutrinoless muon-to-electron conversion by one order of magnitude beyond the Mu2e experiment, providing the deepest probe of charged lepton flavor violation in the fores…
▽ More
We propose an evolution of the Mu2e experiment, called Mu2e-II, that would leverage advances in detector technology and utilize the increased proton intensity provided by the Fermilab PIP-II upgrade to improve the sensitivity for neutrinoless muon-to-electron conversion by one order of magnitude beyond the Mu2e experiment, providing the deepest probe of charged lepton flavor violation in the foreseeable future. Mu2e-II will use as much of the Mu2e infrastructure as possible, providing, where required, improvements to the Mu2e apparatus to accommodate the increased beam intensity and cope with the accompanying increase in backgrounds.
△ Less
Submitted 7 February, 2018;
originally announced February 2018.
-
Calorimeter development for the SuperNEMO double beta decay experiment
Authors:
A. S. Barabash,
A. Basharina-Freshville,
S. Blot,
M. Bongrand,
Ch. Bourgeois,
D. Breton,
V. Brudanin,
H. Burešovà,
J. Busto,
A. J. Caffrey,
S. Calvez,
M. Cascella,
C. Cerna,
J. P. Cesar,
E. Chauveau,
A. Chopra,
G. Claverie,
S. De Capua,
F. Delalee,
D. Duchesneau,
V. Egorov,
G. Eurin,
J. J. Evans,
L. Fajt,
D. Filosofov
, et al. (73 additional authors not shown)
Abstract:
SuperNEMO is a double-$β$ decay experiment, which will employ the successful tracker-calorimeter technique used in the recently completed NEMO-3 experiment. SuperNEMO will implement 100 kg of double-$β$ decay isotope, reaching a sensitivity to the neutrinoless double-$β$ decay ($0νββ$) half-life of the order of $10^{26}$ yr, corresponding to a Majorana neutrino mass of 50-100 meV. One of the main…
▽ More
SuperNEMO is a double-$β$ decay experiment, which will employ the successful tracker-calorimeter technique used in the recently completed NEMO-3 experiment. SuperNEMO will implement 100 kg of double-$β$ decay isotope, reaching a sensitivity to the neutrinoless double-$β$ decay ($0νββ$) half-life of the order of $10^{26}$ yr, corresponding to a Majorana neutrino mass of 50-100 meV. One of the main goals and challenges of the SuperNEMO detector development programme has been to reach a calorimeter energy resolution, $Δ$E/E, around 3%/$sqrt(E)$(MeV) $σ$, or 7%/$sqrt(E)$(MeV) FWHM (full width at half maximum), using a calorimeter composed of large volume plastic scintillator blocks coupled to photomultiplier tubes. We describe the R\&D programme and the final design of the SuperNEMO calorimeter that has met this challenging goal.
△ Less
Submitted 21 July, 2017;
originally announced July 2017.
-
The BiPo-3 detector for the measurement of ultra low natural radioactivities of thin materials
Authors:
A. S. Barabash,
A. Basharina-Freshville,
E. Birdsall,
S. Blondel,
S. Blot,
M. Bongrand,
D. Boursette,
V. Brudanin,
J. Busto,
A. J. Caffrey,
S. Calvez,
M. Cascella,
S. Cebrián,
C. Cerna,
J. P Cesar,
E. Chauveau,
A. Chopra,
T. Dafní,
S. De Capua,
D. Duchesneau,
D. Durand,
V. Egorov,
G. Eurin,
J. J. Evans,
L. Fajt
, et al. (71 additional authors not shown)
Abstract:
The BiPo-3 detector, running in the Canfranc Underground Laboratory (Laboratorio Subterráneo de Canfranc, LSC, Spain) since 2013, is a low-radioactivity detector dedicated to measuring ultra low natural radionuclide contaminations of $^{208}$Tl ($^{232}$Th chain) and $^{214}$Bi ($^{238}$U chain) in thin materials. The total sensitive surface area of the detector is 3.6 m$^2$. The detector has been…
▽ More
The BiPo-3 detector, running in the Canfranc Underground Laboratory (Laboratorio Subterráneo de Canfranc, LSC, Spain) since 2013, is a low-radioactivity detector dedicated to measuring ultra low natural radionuclide contaminations of $^{208}$Tl ($^{232}$Th chain) and $^{214}$Bi ($^{238}$U chain) in thin materials. The total sensitive surface area of the detector is 3.6 m$^2$. The detector has been developed to measure radiopurity of the selenium double $β$-decay source foils of the SuperNEMO experiment. In this paper the design and performance of the detector, and results of the background measurements in $^{208}$Tl and $^{214}$Bi, are presented, and validation of the BiPo-3 measurement with a calibrated aluminium foil is discussed. Results of the $^{208}$Tl and $^{214}$Bi activity measurements of the first enriched $^{82}$Se foils of the double $β$-decay SuperNEMO experiment are reported. The sensitivity of the BiPo-3 detector for the measurement of the SuperNEMO $^{82}$Se foils is $\mathcal{A}$($^{208}$Tl) $<2$ $μ$Bq/kg (90\% C.L.) and $\mathcal{A}$($^{214}$Bi) $<140$ $μ$Bq/kg (90\% C.L.) after 6 months of measurement.
△ Less
Submitted 7 June, 2017; v1 submitted 23 February, 2017;
originally announced February 2017.
-
Measurement of the $2νββ$ Decay Half-Life and Search for the $0νββ$ Decay of $^{116}$Cd with the NEMO-3 Detector
Authors:
NEMO-3 Collaboration,
:,
R. Arnold,
C. Augier,
J. D. Baker,
A. S. Barabash,
A. Basharina-Freshville,
S. Blondel,
S. Blot,
M. Bongrand,
D. Boursette,
V. Brudanin,
J. Busto,
A. J. Caffrey,
S. Calvez,
M. Cascella,
C. Cerna,
J. P. Cesar,
A. Chapon,
E. Chauveau,
A. Chopra,
D. Duchesneau,
D. Durand,
V. Egorov,
G. Eurin
, et al. (73 additional authors not shown)
Abstract:
The NEMO-3 experiment measured the half-life of the $2νββ$ decay and searched for the $0νββ$ decay of $^{116}$Cd. Using $410$ g of $^{116}$Cd installed in the detector with an exposure of $5.26$ y, ($4968\pm74$) events corresponding to the $2νββ$ decay of $^{116}$Cd to the ground state of $^{116}$Sn have been observed with a signal to background ratio of about $12$. The half-life of the $2νββ$ dec…
▽ More
The NEMO-3 experiment measured the half-life of the $2νββ$ decay and searched for the $0νββ$ decay of $^{116}$Cd. Using $410$ g of $^{116}$Cd installed in the detector with an exposure of $5.26$ y, ($4968\pm74$) events corresponding to the $2νββ$ decay of $^{116}$Cd to the ground state of $^{116}$Sn have been observed with a signal to background ratio of about $12$. The half-life of the $2νββ$ decay has been measured to be $ T_{1/2}^{2ν}=[2.74\pm0.04\mbox{(stat.)}\pm0.18\mbox{(syst.)}]\times10^{19}$ y. No events have been observed above the expected background while searching for $0νββ$ decay. The corresponding limit on the half-life is determined to be $T_{1/2}^{0ν} \ge 1.0 \times 10^{23}$ y at the $90$ % C.L. which corresponds to an upper limit on the effective Majorana neutrino mass of $\langle m_ν \rangle \le 1.4-2.5$ eV depending on the nuclear matrix elements considered. Limits on other mechanisms generating $0νββ$ decay such as the exchange of R-parity violating supersymmetric particles, right-handed currents and majoron emission are also obtained.
△ Less
Submitted 23 December, 2016; v1 submitted 11 October, 2016;
originally announced October 2016.
-
Measurement of the 2$νββ$ decay half-life of $^{150}$Nd and a search for 0$νββ$ decay processes with the full exposure from the NEMO-3 detector
Authors:
NEMO-3 Collaboration,
:,
R. Arnold,
C. Augier,
J. D. Baker,
A. S. Barabash,
A. Basharina-Freshville,
S. Blondel,
S. Blot,
M. Bongrand,
V. Brudanin,
J. Busto,
A. J. Caffrey,
S. Calvez,
M. Cascell,
C. Cerna,
J. P. Cesar,
A. Chapon,
E. Chauveau,
A. Chopra,
D. Duchesneau,
D. Durand,
V. Egorov,
G. Eurin,
J. J. Evans
, et al. (71 additional authors not shown)
Abstract:
We present results from a search for neutrinoless double-$β$ ($0νββ$) decay using 36.6 g of the isotope $^{150}$Nd with data corresponding to a live time of 5.25 y recorded with the NEMO-3 detector. We construct a complete background model for this isotope, including a measurement of the two-neutrino double-$β$ decay half-life of $T^{2ν}_{1/2}=$[9.34 $\pm$ 0.22 (stat.) $^{+0.62}_{-0.60}$ (syst.)]…
▽ More
We present results from a search for neutrinoless double-$β$ ($0νββ$) decay using 36.6 g of the isotope $^{150}$Nd with data corresponding to a live time of 5.25 y recorded with the NEMO-3 detector. We construct a complete background model for this isotope, including a measurement of the two-neutrino double-$β$ decay half-life of $T^{2ν}_{1/2}=$[9.34 $\pm$ 0.22 (stat.) $^{+0.62}_{-0.60}$ (syst.)]$\times 10^{18}$ y for the ground state transition, which represents the most precise result to date for this isotope. We perform a multivariate analysis to search for \zeronu decays in order to improve the sensitivity and, in the case of observation, disentangle the possible underlying decay mechanisms. As no evidence for \zeronu decay is observed, we derive lower limits on half-lives for several mechanisms involving physics beyond the Standard Model. The observed lower limit, assuming light Majorana neutrino exchange mediates the decay, is $T^{0ν}_{1/2} >$ 2.0 $\times 10^{22}$ y at the 90% C.L., corresponding to an upper limit on the effective neutrino mass of $\langle m_ν \rangle$ $<$ 1.6 - 5.3 eV..
△ Less
Submitted 12 October, 2016; v1 submitted 27 June, 2016;
originally announced June 2016.
-
Measurement of the double-beta decay half-life and search for the neutrinoless double-beta decay of $^{48}{\rm Ca}$ with the NEMO-3 detector
Authors:
NEMO-3 Collaboration,
:,
R. Arnold,
C. Augier,
A. M. Bakalyarov,
J. D. Baker,
A. S. Barabash,
A. Basharina-Freshville,
S. Blondel,
S. Blot,
M. Bongrand,
V. Brudanin,
J. Busto,
A. J. Caffrey,
S. Calvez,
M. Cascella,
C. Cerna,
J. P. Cesar,
A. Chapon,
E. Chauveau,
A. Chopra,
D. Duchesneau,
D. Durand,
V. Egorov,
G. Eurin
, et al. (75 additional authors not shown)
Abstract:
The NEMO-3 experiment at the Modane Underground Laboratory has investigated the double-$β$ decay of $^{48}{\rm Ca}$. Using $5.25$ yr of data recorded with a $6.99\,{\rm g}$ sample of $^{48}{\rm Ca}$, approximately $150$ double-$β$ decay candidate events have been selected with a signal-to-background ratio greater than $3$. The half-life for the two-neutrino double-$β$ decay of $^{48}{\rm Ca}$ has…
▽ More
The NEMO-3 experiment at the Modane Underground Laboratory has investigated the double-$β$ decay of $^{48}{\rm Ca}$. Using $5.25$ yr of data recorded with a $6.99\,{\rm g}$ sample of $^{48}{\rm Ca}$, approximately $150$ double-$β$ decay candidate events have been selected with a signal-to-background ratio greater than $3$. The half-life for the two-neutrino double-$β$ decay of $^{48}{\rm Ca}$ has been measured to be $T^{2ν}_{1/2}\,=\,[6.4\, ^{+0.7}_{-0.6}{\rm (stat.)} \, ^{+1.2}_{-0.9}{\rm (syst.)}] \times 10^{19}\,{\rm yr}$. A search for neutrinoless double-$β$ decay of $^{48}{\rm Ca}$ yields a null result and a corresponding lower limit on the half-life is found to be $T^{0ν}_{1/2} > 2.0 \times 10^{22}\,{\rm yr}$ at $90\%$ confidence level, translating into an upper limit on the effective Majorana neutrino mass of $< m_{ββ} > < 6.0 - 26$ ${\rm eV}$, with the range reflecting different nuclear matrix element calculations. Limits are also set on models involving Majoron emission and right-handed currents.
△ Less
Submitted 16 June, 2016; v1 submitted 6 April, 2016;
originally announced April 2016.
-
Reference material for natural radionuclides in glass designed for underground experiments
Authors:
P. P. Povinec,
M. K. Pham,
J. Busto,
C. Cerna,
D. Degering,
Y. Hamajima,
K. Holy,
M. Hult,
M. Jeskovsky,
M. Koehler,
A. Kovacik,
M. Laubenstein,
P. Loaiza,
F. Mamedov,
C. Marquet,
J. Mott,
M. Mullerova,
F. Perrot,
F. Piquemal,
J. -L. Reyss,
R. Saakyan,
H. Simgen,
B. Soule,
J. Stanicek,
I. Sykora
, et al. (1 additional authors not shown)
Abstract:
A reference material designed for the determination of natural radionuclides in solid samples (glass pellets) is described and the results of certification are presented. The material has been certified for 7 natural radionuclides (40K, 226Ra, 228Ra, 228Th, 232Th, 235U and 238U). An information value is given for 210Pb. Radon (222Rn) emanation experiments showed results comparable within participa…
▽ More
A reference material designed for the determination of natural radionuclides in solid samples (glass pellets) is described and the results of certification are presented. The material has been certified for 7 natural radionuclides (40K, 226Ra, 228Ra, 228Th, 232Th, 235U and 238U). An information value is given for 210Pb. Radon (222Rn) emanation experiments showed results comparable within participating laboratories, however, the number of data and precision was too low to carry out a certification process. The reference material may be used for quality management of analytical laboratories engaged in the high-sensitive analysis of radionuclides in the construction materials of detectors placed in ultra low background underground laboratories.
△ Less
Submitted 12 July, 2015;
originally announced July 2015.
-
Result of the search for neutrinoless double-$β$ decay in $^{100}$Mo with the NEMO-3 experiment
Authors:
R. Arnold,
C. Augier,
J. D. Baker,
A. S. Barabash,
A. Basharina-Freshville,
S. Blondel,
S. Blot,
M. Bongrand,
V. Brudanin,
J. Busto,
A. J. Caffrey,
S. Calvez,
C. Cerna,
J. P. Cesar,
A. Chapon,
E. Chauveau,
D. Duchesneau,
D. Durand,
V. Egorov,
G. Eurin,
J. J. Evans,
L. Fajt,
D. Filosofov,
R. Flack,
X. Garrido
, et al. (65 additional authors not shown)
Abstract:
The NEMO-3 detector, which had been operating in the Modane Underground Laboratory from 2003 to 2010, was designed to search for neutrinoless double $β$ ($0νββ$) decay. We report final results of a search for $0νββ$ decays with $6.914$ kg of $^{100}$Mo using the entire NEMO-3 data set with a detector live time of $4.96$ yr, which corresponds to an exposure of 34.3 kg$\cdot$yr. We perform a detaile…
▽ More
The NEMO-3 detector, which had been operating in the Modane Underground Laboratory from 2003 to 2010, was designed to search for neutrinoless double $β$ ($0νββ$) decay. We report final results of a search for $0νββ$ decays with $6.914$ kg of $^{100}$Mo using the entire NEMO-3 data set with a detector live time of $4.96$ yr, which corresponds to an exposure of 34.3 kg$\cdot$yr. We perform a detailed study of the expected background in the $0νββ$ signal region and find no evidence of $0νββ$ decays in the data. The level of observed background in the $0νββ$ signal region $[2.8-3.2]$ MeV is $0.44 \pm 0.13$ counts/yr/kg, and no events are observed in the interval $[3.2-10]$ MeV. We therefore derive a lower limit on the half-life of $0νββ$ decays in $^{100}$Mo of $T_{1/2}(0νββ)> 1.1 \times 10^{24}$ yr at the $90\%$ Confidence Level, under the hypothesis of light Majorana neutrino exchange. Depending on the model used for calculating nuclear matrix elements, the limit for the effective Majorana neutrino mass lies in the range $\langle m_ν \rangle < 0.33$--$0.62$ eV. We also report constraints on other lepton-number violating mechanisms for $0νββ$ decays.
△ Less
Submitted 22 October, 2015; v1 submitted 18 June, 2015;
originally announced June 2015.
-
Muon (g-2) Technical Design Report
Authors:
J. Grange,
V. Guarino,
P. Winter,
K. Wood,
H. Zhao,
R. M. Carey,
D. Gastler,
E. Hazen,
N. Kinnaird,
J. P. Miller,
J. Mott,
B. L. Roberts,
J. Benante,
J. Crnkovic,
W. M. Morse,
H. Sayed,
V. Tishchenko,
V. P. Druzhinin,
B. I. Khazin,
I. A. Koop,
I. Logashenko,
Y. M. Shatunov,
E. Solodov,
M. Korostelev,
D. Newton
, et al. (176 additional authors not shown)
Abstract:
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should…
▽ More
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should be able to determine definitively whether or not the E821 result is evidence for physics beyond the Standard Model. After a review of the physics motivation and the basic technique, which will use the muon storage ring built at BNL and now relocated to Fermilab, the design of the new experiment is presented. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-2/3 approval.
△ Less
Submitted 11 May, 2018; v1 submitted 27 January, 2015;
originally announced January 2015.
-
Mu2e Technical Design Report
Authors:
L. Bartoszek,
E. Barnes,
J. P. Miller,
J. Mott,
A. Palladino,
J. Quirk,
B. L. Roberts,
J. Crnkovic,
V. Polychronakos,
V. Tishchenko,
P. Yamin,
C. -h. Cheng,
B. Echenard,
K. Flood,
D. G. Hitlin,
J. H. Kim,
T. S. Miyashita,
F. C. Porter,
M. Röhrken,
J. Trevor,
R. -Y. Zhu,
E. Heckmaier,
T. I. Kang,
G. Lim,
W. Molzon
, et al. (238 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the L…
▽ More
The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the LHC. We describe herein the preliminary design of the proposed Mu2e experiment. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-2 approval.
△ Less
Submitted 16 March, 2015; v1 submitted 21 January, 2015;
originally announced January 2015.