-
Graded lithium-ion battery pouch cells to homogenise current distributions and mitigate lithium plating
Authors:
Ross Drummond,
Eloise C. Tredenick,
Toby L. Kirk,
Marveh Forghani,
Patrick S. Grant,
Stephen R. Duncan
Abstract:
Spatial distributions in current, temperature, state-of-charge and degradation across the plane of large format lithium-ion battery pouch cells can significantly impact their performance, especially at high C-rates. In this paper, a method to smooth out these spatial distributions by grading the electrode microstructure in-the-plane is proposed. A mathematical model of a large format pouch cell is…
▽ More
Spatial distributions in current, temperature, state-of-charge and degradation across the plane of large format lithium-ion battery pouch cells can significantly impact their performance, especially at high C-rates. In this paper, a method to smooth out these spatial distributions by grading the electrode microstructure in-the-plane is proposed. A mathematical model of a large format pouch cell is developed and validated against both temperature and voltage experimental data. An analytic solution for the optimal graded electrode that achieves a uniform current distribution across the pouch cell is then derived. The model predicts that the graded electrodes could significantly reduce the likelihood of lithium plating in large format pouch cells, with grading increasing the C-rate at which plating occurs from 2.75C to 5.5C. These results indicate the potential of designing spatially varying electrode architectures to homogenise the response of large format pouch cells and improve their high rate performance.
△ Less
Submitted 28 July, 2024;
originally announced July 2024.
-
Leveraging Geospatial Information to address Space Epidemiology through Multi$\unicode{x2013}$omics $\unicode{x2013}$ Report of an Interdisciplinary Workshop
Authors:
Annette L. Sobel,
Kenneth Yeh,
Elaine Bradford,
Colin Price,
Joseph Russell,
Gene Olinger,
Sheila Grant,
Chi-Ren Shyu
Abstract:
This article will summarize the workshop proceedings of a workshop conducted at the University of Missouri that addressed the use of multi-omics fused with geospatial information to assess and improve the precision and environmental analysis of indicators of crew space health. The workshop addressed the state of the art of multi-omics research and practice and the potential future use of multi-omi…
▽ More
This article will summarize the workshop proceedings of a workshop conducted at the University of Missouri that addressed the use of multi-omics fused with geospatial information to assess and improve the precision and environmental analysis of indicators of crew space health. The workshop addressed the state of the art of multi-omics research and practice and the potential future use of multi-omics platforms in extreme environments. The workshop also focused on potential new strategies for data collection, analysis, and fusion with crosstalk with the field of environmental health, biosecurity, and radiation safety, addressing gaps and shortfalls and potential new approaches to enhancing astronaut health safety and security. Ultimately, the panel proceedings resulted in a synthesis of new research and translational opportunities to improve space and terrestrial epidemiology. In the future, early disease prevention that employs new and expanded data sources enhanced by the analytic precision of geospatial information and artificial intelligence algorithms.
△ Less
Submitted 11 August, 2023;
originally announced August 2023.
-
Method for in-solution, high-throughput T1 relaxometry using fluorescent nanodiamonds
Authors:
Erin. S. Grant,
Mina Barzegar Amiri Olia,
Ella. P. Walsh,
Liam T. Hall,
Gawain McColl,
David A. Simpson
Abstract:
Fluorescent nanodiamonds (FNDs) have been exploited as sensitive quantum probes for nanoscale chemical and biological sensing applications, with the majority of demonstrations to date relying on the detection of single FNDs. This places significant limits on the measurement time, throughput and statistical significance of a measured result as there is usually marked inhomogeneity within FND sample…
▽ More
Fluorescent nanodiamonds (FNDs) have been exploited as sensitive quantum probes for nanoscale chemical and biological sensing applications, with the majority of demonstrations to date relying on the detection of single FNDs. This places significant limits on the measurement time, throughput and statistical significance of a measured result as there is usually marked inhomogeneity within FND samples. Here we have developed a measurement platform that can report the T1 spin relaxation time from a large ensemble of FNDs in solution. We first describe a refined sensing protocol for this modality and then use it to identify the optimal FND size for the detection of paramagnetic targets. Our approach is simple to set up, robust and can be used for rapid material characterisation or a variety of in-situ quantum sensing applications.
△ Less
Submitted 27 November, 2022;
originally announced November 2022.
-
Recommendations and guidelines from the ISMRM Diffusion Study Group for preclinical diffusion MRI: Part 2 -- Ex vivo imaging
Authors:
Kurt G Schilling,
Francesco Grussu,
Andrada Ianus,
Brian Hansen,
Rachel L C Barrett,
Manisha Aggarwal,
Stijn Michielse,
Fatima Nasrallah,
Warda Syeda,
Nian Wang,
Jelle Veraart,
Alard Roebroeck,
Andrew F Bagdasarian,
Cornelius Eichner,
Farshid Sepehrband,
Jan Zimmermann,
Lucas Soustelle,
Christien Bowman,
Benjamin C Tendler,
Andreea Hertanu,
Ben Jeurissen,
Lucio Frydman,
Yohan van de Looij,
David Hike,
Jeff F Dunn
, et al. (31 additional authors not shown)
Abstract:
The value of preclinical diffusion MRI (dMRI) is substantial. While dMRI enables in vivo non-invasive characterization of tissue, ex vivo dMRI is increasingly being used to probe tissue microstructure and brain connectivity. Ex vivo dMRI has several experimental advantages including higher signal-to-noise ratio and spatial resolution compared to in vivo studies, and more advanced diffusion contras…
▽ More
The value of preclinical diffusion MRI (dMRI) is substantial. While dMRI enables in vivo non-invasive characterization of tissue, ex vivo dMRI is increasingly being used to probe tissue microstructure and brain connectivity. Ex vivo dMRI has several experimental advantages including higher signal-to-noise ratio and spatial resolution compared to in vivo studies, and more advanced diffusion contrasts for improved microstructure and connectivity characterization. Another major advantage is direct comparison with histological data as a crucial methodological validation. However, there are a number of considerations that must be made when performing ex vivo experiments. The steps from tissue preparation, image acquisition and processing, and interpretation of results are complex, with many decisions that not only differ dramatically from in vivo imaging, but ultimately affect what questions can be answered using the data. This work represents 'Part 2' of a series of recommendations and considerations for preclinical dMRI, where we focus on best practices for dMRI of ex vivo tissue. We first describe the value that ex vivo imaging adds to the field of dMRI, followed by general considerations and foundational knowledge that must be considered when designing experiments. We then give guidelines for ex vivo protocols, including tissue preparation, imaging sequences and data processing including pre-processing, model-fitting, and tractography. Finally, we provide an online resource which lists publicly available ex vivo dMRI datasets and dedicated software packages. In each section, we attempt to provide guidelines and recommendations, but also highlight areas for which no guidelines exist, and where future work should lie. An overarching goal herein is to enhance the rigor and reproducibility of ex vivo dMRI acquisitions and analyses, and thereby advance biomedical knowledge.
△ Less
Submitted 7 February, 2023; v1 submitted 27 September, 2022;
originally announced September 2022.
-
Recommendations and guidelines from the ISMRM Diffusion Study Group for preclinical diffusion MRI: Part 1 -- In vivo small-animal imaging
Authors:
Ileana O Jelescu,
Francesco Grussu,
Andrada Ianus,
Brian Hansen,
Rachel L C Barrett,
Manisha Aggarwal,
Stijn Michielse,
Fatima Nasrallah,
Warda Syeda,
Nian Wang,
Jelle Veraart,
Alard Roebroeck,
Andrew F Bagdasarian,
Cornelius Eichner,
Farshid Sepehrband,
Jan Zimmermann,
Lucas Soustelle,
Christien Bowman,
Benjamin C Tendler,
Andreea Hertanu,
Ben Jeurissen,
Marleen Verhoye,
Lucio Frydman,
Yohan van de Looij,
David Hike
, et al. (32 additional authors not shown)
Abstract:
The value of in vivo preclinical diffusion MRI (dMRI) is substantial. Small-animal dMRI has been used for methodological development and validation, characterizing the biological basis of diffusion phenomena, and comparative anatomy. Many of the influential works in this field were first performed in small animals or ex vivo samples. The steps from animal setup and monitoring, to acquisition, anal…
▽ More
The value of in vivo preclinical diffusion MRI (dMRI) is substantial. Small-animal dMRI has been used for methodological development and validation, characterizing the biological basis of diffusion phenomena, and comparative anatomy. Many of the influential works in this field were first performed in small animals or ex vivo samples. The steps from animal setup and monitoring, to acquisition, analysis, and interpretation are complex, with many decisions that may ultimately affect what questions can be answered using the data. This work aims to serve as a reference, presenting selected recommendations and guidelines from the diffusion community, on best practices for preclinical dMRI of in vivo animals. In each section, we also highlight areas for which no guidelines exist (and why), and where future work should focus. We first describe the value that small animal imaging adds to the field of dMRI, followed by general considerations and foundational knowledge that must be considered when designing experiments. We briefly describe differences in animal species and disease models and discuss how they are appropriate for different studies. We then give guidelines for in vivo acquisition protocols, including decisions on hardware, animal preparation, imaging sequences and data processing, including pre-processing, model-fitting, and tractography. Finally, we provide an online resource which lists publicly available preclinical dMRI datasets and software packages, to promote responsible and reproducible research. An overarching goal herein is to enhance the rigor and reproducibility of small animal dMRI acquisitions and analyses, and thereby advance biomedical knowledge.
△ Less
Submitted 21 April, 2023; v1 submitted 26 September, 2022;
originally announced September 2022.
-
The Straw Tracking Detector for the Fermilab Muon $g-2$ Experiment
Authors:
B. T. King,
T. Albahri,
S. Al-Kilani,
D. Allspach,
D. Beckner,
A. Behnke,
T. J. V. Bowcock,
D. Boyden,
R. M. Carey,
J. Carroll,
B. C. K. Casey,
S. Charity,
R. Chislett,
M. Eads,
A. Epps,
S. B. Foster,
D. Gastler,
S. Grant,
T. Halewood-Leagas,
K. Hardin,
E. Hazen,
G. Hesketh,
D. J. Hollywood,
T. Jones,
C. Kenziora
, et al. (32 additional authors not shown)
Abstract:
The Muon $g-2$ Experiment at Fermilab uses a gaseous straw tracking detector to make detailed measurements of the stored muon beam profile, which are essential for the experiment to achieve its uncertainty goals. Positrons from muon decays spiral inward and pass through the tracking detector before striking an electromagnetic calorimeter. The tracking detector is therefore located inside the vacuu…
▽ More
The Muon $g-2$ Experiment at Fermilab uses a gaseous straw tracking detector to make detailed measurements of the stored muon beam profile, which are essential for the experiment to achieve its uncertainty goals. Positrons from muon decays spiral inward and pass through the tracking detector before striking an electromagnetic calorimeter. The tracking detector is therefore located inside the vacuum chamber in a region where the magnetic field is large and non-uniform. As such, the tracking detector must have a low leak rate to maintain a high-quality vacuum, must be non-magnetic so as not to perturb the magnetic field and, to minimize energy loss, must have a low radiation length. The performance of the tracking detector has met or surpassed the design requirements, with adequate electronic noise levels, an average straw hit resolution of $(110 \pm 20) \,μ$m, a detection efficiency of 97% or higher, and no performance degradation or signs of aging. The tracking detector's measurements result in an otherwise unachievable understanding of the muon's beam motion, particularly at early times in the experiment's measurement period when there are a significantly greater number of muons decaying. This is vital to the statistical power of the experiment, as well as facilitating the precise extraction of several systematic corrections and uncertainties. This paper describes the design, construction, testing, commissioning, and performance of the tracking detector.
△ Less
Submitted 24 February, 2022; v1 submitted 3 November, 2021;
originally announced November 2021.
-
Beam dynamics corrections to the Run-1 measurement of the muon anomalous magnetic moment at Fermilab
Authors:
T. Albahri,
A. Anastasi,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
G. Cantatore,
R. M. Carey,
B. C. K. Casey,
D. Cauz,
R. Chakraborty,
S. P. Chang,
A. Chapelain,
S. Charity,
R. Chislett
, et al. (152 additional authors not shown)
Abstract:
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is fe…
▽ More
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is felt by relativistic muons passing transversely through the radial electric field components created by the ESQ system. The correction depends on the stored momentum distribution and the tunes of the ring, which has relatively weak vertical focusing. Vertical betatron motions imply that the muons do not orbit the ring in a plane exactly orthogonal to the vertical magnetic field direction. A correction is necessary to account for an average pitch angle associated with their trajectories. A third small correction is necessary because muons that escape the ring during the storage time are slightly biased in initial spin phase compared to the parent distribution. Finally, because two high-voltage resistors in the ESQ network had longer than designed RC time constants, the vertical and horizontal centroids and envelopes of the stored muon beam drifted slightly, but coherently, during each storage ring fill. This led to the discovery of an important phase-acceptance relationship that requires a correction. The sum of the corrections to $ω_a^m$ is 0.50 $\pm$ 0.09 ppm; the uncertainty is small compared to the 0.43 ppm statistical precision of $ω_a^m$.
△ Less
Submitted 23 April, 2021; v1 submitted 7 April, 2021;
originally announced April 2021.
-
Finding the mechanism of wave energy flux damping in solar pores using numerical simulations
Authors:
Julia M. Riedl,
Caitlin A. Gilchrist-Millar,
Tom Van Doorsselaere,
David B. Jess,
Samuel D. T. Grant
Abstract:
Context. Solar magnetic pores are, due to their concentrated magnetic fields, suitable guides for magnetoacoustic waves. Recent observations have shown that propagating energy flux in pores is subject to strong damping with height; however, the reason is still unclear. Aims. We investigate possible damping mechanisms numerically to explain the observations. Methods. We performed 2D numerical magne…
▽ More
Context. Solar magnetic pores are, due to their concentrated magnetic fields, suitable guides for magnetoacoustic waves. Recent observations have shown that propagating energy flux in pores is subject to strong damping with height; however, the reason is still unclear. Aims. We investigate possible damping mechanisms numerically to explain the observations. Methods. We performed 2D numerical magnetohydrodynamic (MHD) simulations, starting from an equilibrium model of a single pore inspired by the observed properties. Energy was inserted into the bottom of the domain via different vertical drivers with a period of 30s. Simulations were performed with both ideal MHD and non-ideal effects. Results. While the analysis of the energy flux for ideal and non-ideal MHD simulations with a plane driver cannot reproduce the observed damping, the numerically predicted damping for a localized driver closely corresponds with the observations. The strong damping in simulations with localized driver was caused by two geometric effects, geometric spreading due to diverging field lines and lateral wave leakage.
△ Less
Submitted 24 February, 2021;
originally announced February 2021.
-
Nuclear Magnetic Resonance Diffusometry of Linear and Branched Wormlike Micelles
Authors:
Samuel W. Holder,
Samuel C. Grant,
Hadi Mohammadigoushki
Abstract:
Diffusion studies using nuclear magnetic resonance (NMR) spectroscopy were conducted on two model surfactant solutions of cetyltrimethylammonium bromide/sodium salicylate (CTAB/NaSal) and cetylpyridinium chloride/sodium salicylate (CPCl/NaSal). By increasing the salt-to-surfactant concentration ratio, these systems display two peaks in the zero-shear viscosity and relaxation time, which are indica…
▽ More
Diffusion studies using nuclear magnetic resonance (NMR) spectroscopy were conducted on two model surfactant solutions of cetyltrimethylammonium bromide/sodium salicylate (CTAB/NaSal) and cetylpyridinium chloride/sodium salicylate (CPCl/NaSal). By increasing the salt-to-surfactant concentration ratio, these systems display two peaks in the zero-shear viscosity and relaxation time, which are indicative of transitions from linear to branched micellar networks. The goal of this work is to assess the sensitivity of NMR diffusometry to different types of micellar microstructures and identify the mechanism(s) of surfactant self-diffusion in micellar solutions. At low salt-to-surfactant concentration ratios, for which wormlike micelles are linear, the surfactant self-diffusion is best described by a mean squared displacement, Z2, that varies as Z2 ~ Tdiff 0.5, where Tdiff is the diffusion time. As the salt concentration increases to establish branched micelles, Z2 ~ Tdiff, indicating a Brownian-like self-diffusion of surfactant molecules in branched micelles. This result indicates that NMR diffusometry is capable of differentiating various types of micellar microstructure. In addition, the self-diffusion coefficient of the surfactant molecules in linear and branched micelles are determined, for the first time, by comparing to the existing restricted diffusion models, and shown to be much slower than the diffusion of proton molecules in the bulk. Moreover, in linear and moderately branched wormlike micelles, the dominant mechanism of surfactant self-diffusion is through the curvilinear diffusion of the surfactant molecules along the contour length of the micelles, whereas in the branched micelles, before the second viscosity maxima, the surfactant self-diffusion could arise from a combination of micellar breakage, exchange between micelles and/or the bulk.
△ Less
Submitted 20 February, 2021;
originally announced February 2021.
-
Active metamaterials with negative static electric susceptibility
Authors:
F. Castles,
J. A. J. Fells,
D. Isakov,
S. M. Morris,
A. Watt,
P. S. Grant
Abstract:
Well-established textbook arguments suggest that static electric susceptibility must be positive in "all bodies" [1]. However, it has been pointed out that media that are not in thermodynamic equilibrium are not necessarily subject to this restriction; negative static electric susceptibility has been predicted theoretically in systems with inverted populations of atomic and molecular energy levels…
▽ More
Well-established textbook arguments suggest that static electric susceptibility must be positive in "all bodies" [1]. However, it has been pointed out that media that are not in thermodynamic equilibrium are not necessarily subject to this restriction; negative static electric susceptibility has been predicted theoretically in systems with inverted populations of atomic and molecular energy levels [2,3], though this has never been confirmed experimentally. Here we exploit the design freedom afforded by metamaterials to fabricate active structures that exhibit the first experimental evidence of negative static electric susceptibility. Unlike the systems envisioned previously---which were expected to require reduced temperature and pressure---negative values are readily achieved at room temperature and pressure. Further, values are readily tuneable throughout the negative range of stability -1<χ^{(0)}<0, resulting in magnitudes that are over one thousand times greater than predicted previously [4]. This opens the door to new technological capabilities such as stable electrostatic levitation.
△ Less
Submitted 30 April, 2019; v1 submitted 20 April, 2017;
originally announced April 2017.
-
Traveling Wave MRI at 21.1 T: Propagation below Cut-off for Ultrahigh Field Vertical Bore System
Authors:
Alexey A. Tonyushkin,
Jose A. Muniz,
Samuel C. Grant,
Andrew JM Kiruluta
Abstract:
At high magnetic field strengths (> 4 T), the propagation wave vector of the excitation field B1 can no longer be ignored as the wavelength becomes commensurate or smaller than the imaging field of view (FOV), particularly for high dielectric media. The emergence of this propagation wave vector renders the excitation field variant in both time and space. In this paper, the propagation of RF excita…
▽ More
At high magnetic field strengths (> 4 T), the propagation wave vector of the excitation field B1 can no longer be ignored as the wavelength becomes commensurate or smaller than the imaging field of view (FOV), particularly for high dielectric media. The emergence of this propagation wave vector renders the excitation field variant in both time and space. In this paper, the propagation of RF excitation waves in a high field vertical NMR system is demonstrated for the first time with an appropriate screened dielectric waveguide excited by a simple loop coil to enable below cutoff propagation for imaging in the far field. Uniquely, aqueous samples provide the high permittivity required to modify the cut-off requirements of this transmission system. Theory and simulations corroborate the observed propagating modes field patterns. The ease of construction and implementation of this setup permits use in a variety of high field systems. At a minimum, this design provides a larger FOV that is limited primarily by the three-dimensional linearity of the gradient coil. More critically, it also opens up the use of multimode excitation for selective nulling or maximum excitation of the FOV along the direction of wave propagation.
△ Less
Submitted 5 September, 2014;
originally announced September 2014.
-
Using Multipartite Graphs for Recommendation and Discovery
Authors:
Michael J. Kurtz,
Alberto Accomazzi,
Edwin Henneken,
Giovanni Di Milia,
Carolyn S. Grant
Abstract:
The Smithsonian/NASA Astrophysics Data System exists at the nexus of a dense system of interacting and interlinked information networks. The syntactic and the semantic content of this multipartite graph structure can be combined to provide very specific research recommendations to the scientist/user.
The Smithsonian/NASA Astrophysics Data System exists at the nexus of a dense system of interacting and interlinked information networks. The syntactic and the semantic content of this multipartite graph structure can be combined to provide very specific research recommendations to the scientist/user.
△ Less
Submitted 30 December, 2009;
originally announced December 2009.
-
The Bibliometric Properties of Article Readership Information
Authors:
Michael J. Kurtz,
Guenther Eichhorn,
Alberto Accomazzi,
Carolyn S. Grant,
Markus Demleitner,
Stephen S. Murray,
Nathalie Martimbeau,
Barbara Elwell
Abstract:
The NASA Astrophysics Data System (ADS), along with astronomy's journals and data centers (a collaboration dubbed URANIA), has developed a distributed on-line digital library which has become the dominant means by which astronomers search, access and read their technical literature. Digital libraries such as the NASA Astrophysics Data System permit the easy accumulation of a new type of bibliome…
▽ More
The NASA Astrophysics Data System (ADS), along with astronomy's journals and data centers (a collaboration dubbed URANIA), has developed a distributed on-line digital library which has become the dominant means by which astronomers search, access and read their technical literature. Digital libraries such as the NASA Astrophysics Data System permit the easy accumulation of a new type of bibliometric measure, the number of electronic accesses (``reads'') of individual articles. We explore various aspects of this new measure. We examine the obsolescence function as measured by actual reads, and show that it can be well fit by the sum of four exponentials with very different time constants. We compare the obsolescence function as measured by readership with the obsolescence function as measured by citations. We find that the citation function is proportional to the sum of two of the components of the readership function. This proves that the normative theory of citation is true in the mean. We further examine in detail the similarities and differences between the citation rate, the readership rate and the total citations for individual articles, and discuss some of the causes. Using the number of reads as a bibliometric measure for individuals, we introduce the read-cite diagram to provide a two-dimensional view of an individual's scientific productivity. We develop a simple model to account for an individual's reads and cites and use it to show that the position of a person in the read-cite diagram is a function of age, innate productivity, and work history. We show the age biases of both reads and cites, and develop two new bibliometric measures which have substantially less age bias than citations
△ Less
Submitted 25 September, 2009;
originally announced September 2009.