High-Accuracy Absolute Magnetometry with Application to the Fermilab Muon $g-2$ Experiment
Authors:
D. Flay,
D. Kawall,
T. Chupp,
S. Corrodi,
M. Farooq,
M. Fertl,
J. George,
J. Grange,
R. Hong,
R. Osofsky,
S. Ramachandran,
E. Swanson,
P. Winter
Abstract:
We present details of a high-accuracy absolute scalar magnetometer based on pulsed proton NMR. The $B$-field magnitude is determined from the precession frequency of proton spins in a cylindrical sample of water after accounting for field perturbations from probe materials, sample shape, and other corrections. Features of the design, testing procedures, and corrections necessary for qualification…
▽ More
We present details of a high-accuracy absolute scalar magnetometer based on pulsed proton NMR. The $B$-field magnitude is determined from the precession frequency of proton spins in a cylindrical sample of water after accounting for field perturbations from probe materials, sample shape, and other corrections. Features of the design, testing procedures, and corrections necessary for qualification as an absolute scalar magnetometer are described. The device was tested at $B = 1.45$\,T but can be modified for a range exceeding 1--3\,T. The magnetometer was used to calibrate other NMR magnetometers and measure absolute magnetic field magnitudes to an accuracy of 19 parts per billion as part of a measurement of the muon magnetic moment anomaly at Fermilab.
△ Less
Submitted 22 December, 2021; v1 submitted 18 September, 2021;
originally announced September 2021.
-
Beam dynamics corrections to the Run-1 measurement of the muon anomalous magnetic moment at Fermilab
Authors:
T. Albahri,
A. Anastasi,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
G. Cantatore,
R. M. Carey,
B. C. K. Casey,
D. Cauz,
R. Chakraborty,
S. P. Chang,
A. Chapelain,
S. Charity,
R. Chislett
, et al. (152 additional authors not shown)
Abstract:
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is fe…
▽ More
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is felt by relativistic muons passing transversely through the radial electric field components created by the ESQ system. The correction depends on the stored momentum distribution and the tunes of the ring, which has relatively weak vertical focusing. Vertical betatron motions imply that the muons do not orbit the ring in a plane exactly orthogonal to the vertical magnetic field direction. A correction is necessary to account for an average pitch angle associated with their trajectories. A third small correction is necessary because muons that escape the ring during the storage time are slightly biased in initial spin phase compared to the parent distribution. Finally, because two high-voltage resistors in the ESQ network had longer than designed RC time constants, the vertical and horizontal centroids and envelopes of the stored muon beam drifted slightly, but coherently, during each storage ring fill. This led to the discovery of an important phase-acceptance relationship that requires a correction. The sum of the corrections to $ω_a^m$ is 0.50 $\pm$ 0.09 ppm; the uncertainty is small compared to the 0.43 ppm statistical precision of $ω_a^m$.
△ Less
Submitted 23 April, 2021; v1 submitted 7 April, 2021;
originally announced April 2021.
-
Systematic and Statistical Uncertainties of the Hilbert-Transform Based High-precision FID Frequency Extraction Method
Authors:
Ran Hong,
Simon Corrodi,
Saskia Charity,
Stefan Baessler,
Jason Bono,
Timothy Chupp,
Martin Fertl,
David Flay,
Alejandro Garcia,
Jimin George,
Kevin Louis Giovanetti,
Timothy Gorringe,
Joseph Grange,
Kyun Woo Hong,
David Kawall,
Brendan Kiburg,
Bingzhi Li,
Rachel Osofsky,
Dinko Pocanic,
Suvarna Ramachandran,
Matthias Smith,
Herbert Erik Swanson,
Alec Tewsley-Booth,
Peter Winter,
Tianyu Yang
, et al. (1 additional authors not shown)
Abstract:
Pulsed nuclear magnetic resonance (NMR) is widely used in high-precision magnetic field measurements. The absolute value of the magnetic field is determined from the precession frequency of nuclear magnetic moments. The Hilbert transform is widely used to extract the phase function from the observed free induction decay (FID) signal and then its frequency. In this paper, a detailed implementation…
▽ More
Pulsed nuclear magnetic resonance (NMR) is widely used in high-precision magnetic field measurements. The absolute value of the magnetic field is determined from the precession frequency of nuclear magnetic moments. The Hilbert transform is widely used to extract the phase function from the observed free induction decay (FID) signal and then its frequency. In this paper, a detailed implementation of a Hilbert-transform based FID frequency extraction method is described. How artifacts and noise level in the FID signal affect the extracted phase function are derived analytically. A method of mitigating the artifacts in the extracted phase function of an FID is discussed. Correlations between noises of the phase function samples are studied for different noise spectra. We discovered that the error covariance matrix for the extracted phase function is nearly singular and improper for constructing the $χ^2$ used in the fitting routine. A down-sampling method for fixing the singular covariance matrix has been developed, so that the minimum $χ^2$-fit yields properly the statistical uncertainty of the extracted frequency. Other practical methods of obtaining the statistical uncertainty are also discussed.
△ Less
Submitted 27 January, 2021; v1 submitted 20 January, 2021;
originally announced January 2021.
-
Design and performance of an in-vacuum, magnetic field mapping system for the Muon g-2 experiment
Authors:
S. Corrodi,
P. De Lurgio,
D. Flay,
J. Grange,
R. Hong,
D. Kawall,
M. Oberling,
S. Ramachandran,
P. Winter
Abstract:
The E989 Muon $g-2$ experiment at Fermilab aims to measure the anomalous magnetic moment, $a^{}_μ$, of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession frequency, $ω^{}_a$, and the average magnetic field in terms of the shielded proton Larmor frequency, $ω'^{}_p$. The measurement of $ω'^{}_p$ with a total systematic uncer…
▽ More
The E989 Muon $g-2$ experiment at Fermilab aims to measure the anomalous magnetic moment, $a^{}_μ$, of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession frequency, $ω^{}_a$, and the average magnetic field in terms of the shielded proton Larmor frequency, $ω'^{}_p$. The measurement of $ω'^{}_p$ with a total systematic uncertainty of 70 parts-per-billion involves a combination of various NMR probes. There are 378 probes in fixed locations constantly monitoring field drifts. A water-based probe provides the calibration. A crucial element for the multi-step measurement of $ω'^{}_p$ is the regular mapping of the magnetic field over the muon storage region. The former E821 experiment at Brookhaven employed an in-vacuum field mapping system equipped with 17 NMR probes, which was developed by the University of Heidelberg. We have refurbished and upgraded this system with new probes and electronics. The upgrades include a new communication scheme incorporating time-division multiplexing to separate the important NMR reference clock from the data communication. The addition digitization of the NMR signals replaced the hardware-implemented zero-crossing counting of the E821 system. The digitized signals offer new capabilities in the NMR frequency analysis and its related systematic uncertainties. While the mechanical systems that move the field mapper around the ring have been mostly refurbished, the motion control system was completely replaced with a custom-built electronics centered around a commercial Galil motion controller. Both the field mapping NMR system and its motion control were successfully commissioned at Fermilab and have been in reliable operation during the first data taking periods. This article provides details of the upgrades of the field mapper and its performance.
△ Less
Submitted 10 February, 2021; v1 submitted 13 March, 2020;
originally announced March 2020.
-
Muon (g-2) Technical Design Report
Authors:
J. Grange,
V. Guarino,
P. Winter,
K. Wood,
H. Zhao,
R. M. Carey,
D. Gastler,
E. Hazen,
N. Kinnaird,
J. P. Miller,
J. Mott,
B. L. Roberts,
J. Benante,
J. Crnkovic,
W. M. Morse,
H. Sayed,
V. Tishchenko,
V. P. Druzhinin,
B. I. Khazin,
I. A. Koop,
I. Logashenko,
Y. M. Shatunov,
E. Solodov,
M. Korostelev,
D. Newton
, et al. (176 additional authors not shown)
Abstract:
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should…
▽ More
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should be able to determine definitively whether or not the E821 result is evidence for physics beyond the Standard Model. After a review of the physics motivation and the basic technique, which will use the muon storage ring built at BNL and now relocated to Fermilab, the design of the new experiment is presented. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-2/3 approval.
△ Less
Submitted 11 May, 2018; v1 submitted 27 January, 2015;
originally announced January 2015.